- Table of Contents
-
- H3C SecPath M9000-AI-E8[E16] Multi Service Security Gateway Series Installation Guides-6W101
- 00-Preface
- 01-Chapter 1 Chassis views
- 02-Chapter 2 Preparing for Installation
- 03-Chapter 3 Installing the Gateway
- 04-Chapter 4 Accessing the Gateway and Configuring Basic Settings
- 05-Chapter 5 Troubleshooting
- 06-Chapter 6 Replacing Removable Components
- 07-Appendix A FRUs and Compatibility Matrixes
- 08-Appendix B Technical Specifications
- 09-Appendix C LEDs
- 10-Appendix D Cables
- 11-Appendix E Slot arrangement and interface numbering
- 12-Appendix F Engineering labels
- 13-Appendix G Cabling Recommendations
- 14-Appendix H Repackaging the Gateway
- Related Documents
-
Title | Size | Download |
---|---|---|
07-Appendix A FRUs and Compatibility Matrixes | 54.16 KB |
Appendix A FRUs and compatibility matrixes
Supervisor engine modules
Supervisor engine modules (SEMs) are the core of the control management plane for the device. The SEM model available for the M9000-AI gateway series is shown in Table 1.
Table 1 SEM and gateway compatibility
SEM model |
Applicable gateways |
NSQM5SUP08A1 |
M9000-AI-E8 |
NSQM5SUP16A1 |
M9000-AI-E16 |
For more information about the SEMs, see the card manuals that come with the SEMs.
Switching fabric modules
The switching fabric modules are the core of the switching plane of the device. Table 2 describes the compatibility matrix between the M9000-AI gateways and switching fabric module models.
Table 2 Switching fabric module and gateway compatibility
Switching fabric module model |
Applicable gateway |
NSQM5FAB08A1 |
M9000-AI-E8 |
NSQM5FAB16A1 |
M9000-AI-E16 |
For more information about the switching fabric modules, see the card manuals that come with the switching fabric modules.
AI security engine modules
The AI security engine modules available for the gateway are described in Table 3.
Table 3 AI security engine module and gateway compatibility
AI security engine module model |
Description |
Applicable gateways |
NSQM5AIASKA1 |
AI security engine module |
M9000-AI-E8/M9000-AI-E16 |
NSQM5AIASKB1 |
AI security engine module |
For more information about the AI security engine modules, see the card manuals that come with the AI security engine modules.
Interface switch modules and interface modules
The interface modules and service modules are installed in the slots of the interface switch modules. Table 4 describes the compatibility between interface switch modules and interface modules and service modules.
Table 4 Compatibility matrix between interface switch modules and interface modules and service modules
Interface switch module |
Number of slots |
Available interface modules and service modules |
Applicable gateways |
NSQM5MBSHA1 |
2 |
· NS-C300-CGQ2TG16A1 interface module · NS-C300-QG4TG16A1 interface module · NS-C300-TG24A1 interface module · NS-C600-CGQ6A1 interface module · NS-FWEMPA1 firewall module |
M9000-AI-E8/M9000-AI-E16 |
· NS-AFC2000EMPA1 abnormal flow cleaner module · NS-ADEEMPA0 application delivery engine module · NS-ADEEMPC0 application delivery engine module |
M9000-AI-E8 |
The 100G fiber ports on the gateway support 100/40 Gbps autosensing.
For more information about the interface switch modules, interface modules, and service modules, see the card manuals that come with the interface switch modules, interface modules, and service modules.
Transceiver modules
The gateway supports multiple types of transceiver modules. For the transceiver modules available for the ports on a module, see the user guide for the module.
Power supplies
The power supplies available for the M9000-AI gateways are described in Table 5.
Table 5 Power supply and gateway compatibility
Power supply model |
Applicable gateways |
PSR2400-54A |
M9000-AI-E8/M9000-AI-E16 |
PSR2400-54D |
|
PSR3000-54A |
|
PSR3000-54AHD |
DC power cord
DC power cords are used for connecting the DC power supplies on the gateway to the external DC power supply system.
Table 6 DC power cord specifications
DC power cord |
Length |
Cross-sectional area |
Type |
Description |
0404A0E1 |
3 m (9.84 ft) |
13 mm2 (0.02 in2) |
DC power cord |
Used on the PSR2400-54D power supply |
0404A0E2 |
15 m (49.21 ft) |
13 mm2 (0.02 in2) |
DC power cord |
Used on the PSR2400-54D power supply |
0404A0RL |
3 m (9.84 ft) |
3 × 1.5 mm2 (0.002 in2) |
High-voltage DC power cord |
Used on the PSR3000-54AHD power supply |
AC power cord
AC power cords are used for connecting the power supplies of the gateway to the external AC power supply system.
· Select AC power cords according to the power of the power supply.
· The connector type varies by country or region. Select a compliant connector type as needed.
· For the connector types of different countries or regions, see H3C Power Cords & Cables.