08-Appendix B FRUs and Compatibility Matrixes | 271.24 KB |
8 Appendix B FRUs and compatibility matrixes
For the compatibility between transceiver modules and cards, see H3C S7500E Switch Series Cards and Transceiver Modules Compatibility Matrixes.
MPUs
Table 8-1 MPU specifications (1)
Model |
Port quantity |
|||
Console port |
Network management port |
CF card slot |
Other ports |
|
LSQ1MPUA0 |
1 |
1 |
1 |
N/A |
LSQ1CGV24PSC0 |
1 |
1 |
N/A |
· 20 × 10/100/1000BASE-T RJ-45 ports · 4 x combo interfaces |
LSQ1CGP24TSC0 |
1 |
1 |
N/A |
· 16 × FE/GE SFP ports (LC) · 8 x combo interfaces |
LSQ1CTGS16SC0 |
1 |
1 |
N/A |
16 × 10GE SFP+ ports (LC) |
LSQ1MPUB0 |
1 |
1 |
1 |
N/A |
LSQ1SRPA0 |
1 |
1 |
N/A |
N/A |
LSQ1SRPB0 |
1 |
1 |
1 |
N/A |
LSQ1SRPD0 |
1 |
1 |
1 |
N/A |
LSQ1SRP1CB0 |
1 |
1 |
1 |
N/A |
LSQ1SRP12GB0 |
1 |
1 |
1 |
12 × FE/GE SFP ports (LC) |
LSQ1SRP2XB0 |
1 |
1 |
1 |
2 × 10GE XFP ports (LC) |
Table 8-2 MPU specifications (2)
Model |
Specifications |
|||
Flash memory |
NVRAM |
SDRAM |
Ports |
|
LSQM3MPUA0 |
1 GB |
1 MB |
4 GB |
· 1 × console port · 1 × network management port · 1 × USB port |
LSQM3MPUB0 |
1 GB |
1 MB |
2 GB |
· 1 × console port · 1 × USB console port · 2 × network management ports (one 10/100/1000BASE-T port and one SFP port) · 1 × USB port |
LSQM2MPUC0 |
1 GB |
1 MB |
4 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two 10/100/1000BASE-T ports and two SFP ports) · 1 × USB port |
LSQM2MPUD0 |
1 GB |
1 MB |
4 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two 10/100/1000BASE-T ports and two SFP ports) · 2 × QSFP+ ports · 1 × USB port |
LSQM2MPUDS0 |
1 GB |
1 MB |
4 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two 10/100/1000BASE-T ports and two SFP ports) · 1 × USB port |
LSQM1SRP8X2QE0 |
1 GB |
1 MB |
4 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two 10/100/1000BASE-T ports and two SFP ports) · 8 × SFP+ ports · 2 × QSFP+ ports · 1 × USB port |
LSQM1CGP24TSSC0 |
2 GB |
1 MB |
2 GB |
· 1 × console port · 1 × USB console port · 1 × 10/100/1000BASE-T network management port · 24 × SFP ports · 4 × SFP+ ports · 1 × USB port |
LSQM1CGT24TSSC0 |
2 GB |
1 MB |
2 GB |
· 1 × console port · 1 × USB console port · 1 × 10/100/1000BASE-T network management port · 24 × RJ-45 ports · 4 × SFP+ ports · 1 × USB port |
LSQM1CTGS24QSFD0 |
2 GB |
1 MB |
2 GB |
· 1 × console port · 1 × USB console port · 2 × network management ports (One RJ-45 port and one SFP port) · 24 × 10GBASE-R-SFP+ fiber ports · 2 × 40GBASE-R-QSFP+ fiber ports or 1 × 100G QSFP28 fiber port · 1 × USB port |
|
IMPORTANT: · Among the network management ports on the LSQM3MPUB0, LSQM2MPUC0, LSQM2MPUD0, LSQM1CTGS24QSFD0, LSQM2MPUDS0, and LSQM1SRP8X2QE0 MPUs, only port 0 is available during the startup of the switch. · The two QSFP+ ports on the LSQM2MPUD0 MPU are designed only for IRF connection. They do not forward service packets. · To connect an SFP management Ethernet port on the MPUs, make sure the peer port operates at 1000 Mbps in full-duplex mode. · The USB ports on the MPUs do not support USB extension cables. · The switch does not support mixture of different models of MPUs, except the mixture of an LSQM1CGP24TSSC0 and an LSQM1CGT24TSSC0 MPU. |
Table 8-3 MPU and chassis compatibility matrix
Power module |
Chassis |
||||||||
S7502E |
S7503E-S |
S7503E-M |
S7503E |
S7506E-S |
S7506E/S7506E-MF |
S7506E (non-PoE)/S7506E-MF (non-PoE) |
S7506E-V |
S7510E |
|
LSQ1MPUA0 |
Yes |
No |
No |
No |
No |
No |
No |
No |
No |
LSQ1CGP24TSC0 |
No |
Yes |
No |
No |
No |
No |
No |
No |
No |
LSQ1CGV24PSC0 |
No |
Yes |
No |
No |
No |
No |
No |
No |
No |
LSQ1CTGS16SC0 |
No |
Yes |
No |
No |
No |
No |
No |
No |
No |
LSQ1MPUB0 (Salience VI-Lite) |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQ1SRPA0 (Salience VI-Smart) |
No |
No |
No |
No |
Yes |
No |
No |
No |
No |
LSQ1SRPB0 (Salience VI) |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQ1SRPD0 (Salience VI-Plus) |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQ1SRP1CB0 (Salience VI-Turbo) |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQ1SRP12GB0 (Salience VI-GE) |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQ1SRP2XB0 (Salience VI-10GE) |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQM3MPUA0 |
Yes |
No |
No |
No |
No |
No |
No |
No |
No |
LSQM3MPUB0 |
No |
No |
No |
No |
No |
No |
Yes |
No |
No |
LSQM2MPUC0 |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQM2MPUD0 |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQM2MPUDS0 |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQM1SRP8X2QE0 |
No |
No |
No |
Yes |
No |
Yes |
No |
Yes |
Yes |
LSQM1CGP24TSSC0 |
No |
No |
Yes |
No |
No |
No |
No |
No |
No |
LSQM1CGT24TSSC0 |
No |
No |
Yes |
No |
No |
No |
No |
No |
No |
LSQM1CTGS24QSFD0 |
No |
No |
Yes |
No |
No |
No |
No |
No |
No |
|
NOTE: For the system software versions that an MPU is compatible with, see the MPU manual. |
Service modules
Restrictions and guidelines
Follow these restrictions and guidelines to use service modules:
· For the switch models and system software versions that a service module is compatible with, see the service module manual.
· The model name marked on the front panel of a module might be slightly different from the model name used for sale. For example, LSQ1QGS4SC0 and LSQM1QGS4SC0 identify the same module. LSQ1QGS4SC0 is marked on the module panel. When you order the module, you refer to it as LSQM1QGS4SC0.
· A combo interface is a logical interface that contains an SFP port and an RJ-45 Ethernet port. Only one of them can be activated at a time.
· Service modules supported by the S7510E switch vary by the forwarding mode of the slots. For more information, see device management configuration in H3C S7500E Switch Series Fundamentals Configuration Guide.
· Follow these guidelines to use services modules on an S7502E switch:
¡ Do not use an LSQM1TGS16FD0 interface module with the following modules:
- EC interface modules.
- SD interface modules.
- EB interface modules.
- LSQ1TGS8SC0 interface module.
- LSQ3GV48SC0 interface module.
- OAA modules: LSU1FWCEA0, LSU3FWCEA0, LSU3WCMD0, LSU1ADECEA0, LSU1NSCEA0, LSUM1FWCEAB0, LSU1IPSBEA0, LSU1WCME0, LSQM1WCMX40, and LSQM1WCMX20.
¡ Do not use an FD interface module (except the LSQM1TGS16FD0), FE interface module, LSQM1EPSB0 module, or LSQM1SDNB0 module with the following modules:
- SA interface modules.
- EC interface modules.
- SD interface modules.
- EB interface modules.
- LSQ1TGS8SC0 interface module.
- LSQ3GV48SC0 interface module.
- OAA modules: LSU1FWCEA0, LSU3FWCEA0, LSU3WCMD0, LSU1ADECEA0, LSU1NSCEA0, LSUM1FWCEAB0, LSU1IPSBEA0, LSU1WCME0, LSQM1WCMX40, and LSQM1WCMX20.
¡ Do not use an LSQM1TGS16GPSA0 interface module with the following modules:
- SD interface modules.
- EB interface modules.
- LSQ1TGS8SC0 interface module.
- LSQ3GV48SC0 interface module.
- OAA modules: LSU1FWCEA0, LSU3FWCEA0, LSU3WCMD0, LSU1ADECEA0, LSU1NSCEA0, LSUM1FWCEAB0, LSU1IPSBEA0, LSU1WCME0, LSQM1WCMX40, and LSQM1WCMX20.
· For an S7510E switch installed with an LSQM2MPUC0 MPU, support for FD and FE interface modules depends on the system version:
¡ In a version earlier than R7577P02, the S7510E switch does not support FD or FE interface modules.
¡ In a version between R7577P02 and R7577P04, the S7510E switch supports only LSQM1TGS16FD0 and LSQM1GP40TS8FD0 interface modules.
¡ In a version between R7577P05 and R7577P06, the S7510E switch supports only LSQM1TGS16FD0, LSQM1GP40TS8FD0, and LSQM1TGS48RFE0 interface modules.
¡ In R7585 or later, the S7510E switch supports all FD and FE interface modules.
· After you convert 40G ports on an LSQM1CQGS12SG0 interface module to 100G ports, only ports 1, 4, 7, and 10 are available.
· To avoid module damage, do not install an LSQM2TGS48SG0, LSQM1CGS2FE0, or LSQM1CQGS12SG0 interface module in slot 10 on an S7510E switch.
· 7522 and later versions do not support the LSQ2FWBSC0, LSQ1NSMSC0, LSQ1FWBSC0, LSQ1LBSC0, LSQ1SSLSC0, LSQ1ACGASC0, LSQ1IPSSC0, or LSQ1WCMD0 module.
Interface modules
Table 8-4 Interface module specifications
Model |
Port quantity |
Port type |
Available transceiver modules and network cables |
LSQM1TGS24QSFD0 |
26 |
· 2 × 40GBASE-R-QSFP+ fiber ports or 1 × 100G QSFP28 fiber port · 24 × 10GBASE-R-SFP+ fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable · 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM1CQGS12SG0 |
12 |
4 × 100GBASE-R QSFP28 fiber ports or 12 × 40GBASE-R QSFP+ fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSQM1CGS2FE0 |
2 |
100GBASE-R QSFP28 fiber port |
· QSFP28 transceiver module · QSFP28 DAC cable |
LSQM1QGS24RSG0 |
24 |
40GBASE-R QSFP+ fiber port |
· QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSQ1QGS4SC0 |
4 |
40GBASE-R QSFP+ fiber port |
· QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSQ1QGC4SC0 |
4 |
40GBASE-R-CFP fiber port |
10-GE CFP transceiver module |
LSQ1GP24TXSD0 |
26 |
· 2 × 10GBASE-R/W XFP/LC fiber ports · 16 × 1000BASE-X-SFP/LC fiber ports · 8 × combo interfaces |
· 10-GE XFP transceiver module · FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1P24XGSC0 |
26 |
· 2 × 10GBASE-R XFP/LC fiber ports · 24 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE XFP transceiver module · FE/GE SFP transceiver module |
LSQ1T24XGSC0 |
26 |
· 2 × 10GBASE-R XFP/LC fiber ports · 24 × 10/100/1000BASE-T-RJ45 copper ports |
· 10-GE XFP transceiver module · Category 5 twisted-pair cable |
LSQ1TGX8SD0 |
8 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQ1TGX4SD0 |
4 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQ1TGX4EB0 |
4 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQ1TGX2SC0 |
2 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQ1TGX2SD0 |
2 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQ1TGX2EB0 |
2 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQ1TGX1EA0 |
1 |
10GBASE-R XFP/LC fiber port |
10-GE XFP transceiver module |
LSQM2GT24PTSSC0 |
48 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 20 × 1000BASE-X-SFP/LC fiber ports · 24 × 10/100/1000BASE-T-RJ45 copper ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQM2GT24TSSC0 |
28 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 24 × 10/100/1000BASE-T-RJ45 copper ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module · Category 5 twisted-pair cable |
LSQM3GP44TSSC0 |
48 |
· 4 × 10GBASE-R-SFP+ fiber ports (support for MACsec) · 44 × 1000BASE-X-SFP fiber ports (support for MACsec) |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSQM2GP44TSSC0 |
48 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 44 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSQM1GP40TS8FD0 |
48 |
· 8 × 10GBASE-R-SFP+/LC fiber ports · 40 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSQM2GP40TS8FD0 |
48 |
· 8 × 10GBASE-R-SFP+/LC fiber ports · 40 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSQM1TGS48RSG0 |
48 |
10GBASE-R-SFP+ fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM2TGS48SG0 |
48 |
10GBASE-R SFP+ fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM1TGS48RFE0 |
48 |
10GBASE-R-SFP+ fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM1TGS16GPSA0 |
40 |
· 24 × 1000BASE-X-SFP/LC fiber ports · 16 × 10GBASE-R-SFP+/LC fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM1TGS24FD0 |
24 |
10GBASE-R-SFP+ fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQ1TGS16SC0 |
16 |
10GBASE-R SFP+/LC fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM1TGS16FD0 |
16 |
10GBASE-R SFP+/LC fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQM2TGS16SF0 |
16 |
10GBASE-R SFP+/LC fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSQ1TGS8SC0 |
8 |
10GBASE-R SFP+/LC fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable |
LSQ1TGS4SC0 |
4 |
10GBASE-R SFP+/LC fiber port |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable |
LSQM2GP24TSSA0 |
28 |
· 4 × 10GBASE-R/ SFP+/LC fiber ports · 24 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · FE/GE SFP transceiver module |
LSQM1TGS12EC0 |
12 |
10GBASE-R SFP+/LC fiber port |
10-GE SFP+ transceiver module |
LSQM1XPT12TSFD0 |
20 |
· 12 × 10G EPON OLT/SC fiber ports · 8 × 10GBASE-R-SFP+/LC fiber ports |
· XFP EPON transceiver module · 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable |
LSQM2XPT12TSFD0 |
20 |
· 12 × 10G EPON OLT/SC fiber ports · 8 × 10GBASE-R-SFP+/LC fiber ports |
· SFP+ EPON transceiver module · 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable |
LSQM1PT24TSSC0 |
26 |
· 24 × 1000BASE-PX-SFP/SC fiber ports · 2 × 10GBASE-R SFP+/LC fiber ports |
· SFP EPON transceiver module · 10-GE SFP+ transceiver module · GE SFP transceiver module |
LSQM1PT8TSSC0 |
10 |
· 8 × 1000BASE-PX-SFP/SC fiber ports · 2 × 10GBASE-X-SFP/LC fiber ports |
· SFP EPON transceiver module · 10-GE SFP+ transceiver module · GE SFP transceiver module |
LSQ4PT16PSC0 |
24 |
· 16 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ1PT16PSC0 |
24 |
· 16 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ4PT16PSC0 |
24 |
· 16 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ1PT8PSC0 |
16 |
· 8 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ4PT8PSC0 |
16 |
· 8 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ1PT4PSC0 |
12 |
· 4 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ4PT4PSC0 |
12 |
· 4 × 1000BASE-PX-SFP/SC fiber ports · 8 × 1000BASE-X-SFP/LC fiber ports |
· EPON transceiver module · FE/GE SFP transceiver module |
LSQ1GV40PSC0 |
48 |
· 8 × 1000BASE-X-SFP/LC fiber ports · 40 × 10/100/1000BASE-T-RJ45 copper ports |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GV24PSC0 |
24 |
· 20 × 10/100/1000BASE-T-RJ45 copper ports · 4 × combo interfaces |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GV24PSA0 |
24 |
· 20 × 10/100/1000BASE-T-RJ45 copper ports · 4 × combo interfaces |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GP24TSA0 |
24 |
· 16 × 1000BASE-X-SFP/LC fiber ports · 8 × combo interfaces |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GP24TSC0 |
24 |
· 16 × 1000BASE-X-SFP/LC fiber ports · 8 × combo interfaces |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GP24TEB0 |
24 |
· 16 × 1000BASE-X-SFP/LC fiber ports · 8 × combo interfaces |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GP24TSD0 |
24 |
· 16 × 1000BASE-X-SFP/LC fiber ports · 8 × combo interfaces |
· FE/GE SFP transceiver module · Category 5 twisted-pair cable |
LSQ1GP48SC0 |
48 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQ1GP48SD0 |
48 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQ1GP48EB0 |
48 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQM2GP48SA0 |
48 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQM1GP48FD0 |
48 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQ1GP24SC0 |
24 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQM2GP24SA0 |
24 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQ1GP12SC0 |
12 |
1000BASE-X-SFP/LC fiber port |
FE/GE SFP transceiver module |
LSQ1GP12EA0 |
12 |
1000BASE-X-SFP/LC fiber port |
GE SFP transceiver module |
LSQ1FP48SA0 |
48 |
100BASE-FX-SFP/LC fiber port |
FE SFP transceiver module |
LSQ2FP48SA0 |
48 |
100BASE-FX-SFP/LC fiber port |
FE SFP transceiver module |
LSQM1TGT24FD0 |
24 |
10GBASE-T-RJ45 copper port |
Category 6A/7 twisted-pair cable |
LSQ1GV48SA0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQ1GV48SC0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQM2GT48SA0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQ1GV48SD0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQ3GV48SC0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQM2GT48SC0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQM1GT48FD0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQM4GV48SA0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQM4GV48SC0 |
48 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQ1GT24SC0 |
24 |
10/100/1000BASE-T-RJ45 copper port |
Category 5 twisted-pair cable |
LSQ2FT48SA0 |
48 |
10/100BASE-TX-RJ45 copper port |
Category 5 twisted-pair cable |
LSQ1FV48SA0 |
48 |
10/100BASE-TX-RJ45 copper port |
Category 5 twisted-pair cable |
OAA modules
Table 8-5 OAA module specifications
Model |
Description |
Ports |
Compatible transceiver modules |
LSU1WCME0 |
High-performance access controller module |
· 1 × console port · 1 ×100/1000BASE-T out-of-band management Ethernet port |
Category 5 or above twisted pair cable |
LSU3WCMD0 |
High-performance access controller module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQ1WCMD0 |
High-performance access controller module |
· 1 × console port · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports |
Category 5 twisted pair cable |
LSQM1WCMX20 |
Access controller module |
· 1 × console port · 1 × 10/100/1000BASE-T out-of-band management Ethernet port |
Category 5 twisted pair cable |
LSQM1WCMX40 |
Access controller module |
· 1 × console port · 1 × 10/100/1000BASE-T out-of-band management Ethernet port |
Category 5 twisted pair cable |
LSQM1FWDSC0 |
Firewall module |
· 1 × console port · 1 × USB port (reserved for future use) · 1 × GE Ethernet copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSU1FWCEA0 |
Firewall module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports (reserved) · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSU3FWCEA0 |
Firewall module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSUM1FWCEAB0 |
Firewall module |
· 1 × console port · 2 × USB ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQ2FWBSC0 |
Firewall module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQ1FWBSC0 |
Firewall module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSU1NSCEA0 |
10-GE high performance NetStream module |
· 1 × console port · 2 × USB ports (reserved) · 2 × GE combo interfaces |
· Category 5 or above twisted pair cable · GE SFP transceiver module |
LSQ1NSMSC0 |
NetStream module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQM1NSDSC0 |
NetStream module |
· 1 × console port · 1 × USB port (reserved for future use) · 1 × GE Ethernet copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSU1IPSBEA0 |
Intrusion prevention system module |
· 1 × console port · 2 × USB ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQ1IPSSC0 |
Intrusion prevention system module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQM1IPSDSC0 |
Intrusion prevention system module |
· 1 × console port · 1 × USB port (only for supplying power to a PFC) · 1 × 10/100/1000BASE-T copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSQ1SSLSC0 |
SSL VPN module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQ1ACGASC0 |
Application control gateway module |
· 1 × console port · 1 × CF card slot (supporting 256-MB, 512-MB, and 1-GB CF cards) · 2 × USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQM1ACGDSC0 |
Application control gateway module |
· 1 × console port · 1 × USB port (reserved) · 1 × 10/100/1000BASE-T copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSU1ADECEA0 |
Application delivery engine module |
· 1 × console port · 2 × USB ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQM1ADEDSC0 |
Application delivery engine module |
· 1 × console port · 1 × USB port (only for supplying power to a PFC) · 1 × 10/100/1000BASE-T copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSQ1LBSC0 |
Load balancing module |
· 1 × console port · 1 × CF card slot (supporting a 256-MB, 512-MB, or 1-GB CF card) · 2 USB ports · 2 × 10/100/1000BASE-T copper ports · 2 × GE combo interfaces |
· Category 5 twisted pair cable · GE SFP transceiver module |
LSQM2FWDSC0 |
High-performance service module |
· 1 × console port · 2 × USB ports · 2 × GE combo interfaces · 4 × 10GBASE-R fiber ports · 1 × hard disk |
· Category 5 twisted-pair cable · GE SFP transceiver module · 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable |
LSQM1EPSB0 |
EPS endpoint security module |
· 3 × USB 2.0 ports (used by technical support for debugging only) · 1 × VGA connector · 1 × 10/100/1000BASE-T management Ethernet port · 1 × console port (used by technical support for debugging only) |
Category 5 twisted-pair cable |
LSQM1SDNB0 |
SDN automation module |
· 3 × USB 2.0 ports (used by technical support for debugging only) · 1 × VGA connector · 1 × 10/100/1000BASE-T management Ethernet port · 1 × console port (used by technical support for debugging only) |
Category 5 twisted-pair cable |
LSQM1WBCZ720X |
Multiservice access controller module |
· 3 × USB 2.0 ports (used by technical support for debugging only) · 1 × VGA connector · 1 × 1000BASE-T management Ethernet port · 1 × console port |
Category 5 twisted-pair cable |
Power system
Restrictions and guidelines
Before you order a power module, make sure you have read the following restrictions and guidelines:
· A chassis must be configured with a minimum of one power module. To improve power supply availability, you can configure a chassis with two power modules for redundancy.
· The power modules installed on an S7500E switch must be the same type (AC or DC) and model.
· Make sure the maximum output power of a power module is greater than the total power consumption of the switch. As a best practice, reserve 20% of the maximum output power. For more information about the total power consumption, see "Module power consumption."
· If you want the switch to provide PoE power for PDs, order a power module that can be used for setting up a PoE system. Make sure the maximum PoE power provided by the power module is greater than the PoE power consumption. The requirements for setting up a PoE system vary by switch model. For more information about setting up a PoE system, see "(Optional) Setting up a PoE system."
Power modules
|
CAUTION: · Do not install a PSR1200-A/PSR1200-D power module on an LSQM1PWRSPA power module adapter. · Do not install an LSQM1PWRSPA power module adapter on an S7510E switch. |
Table 8-6 Power module specifications (1)
Item |
PSR320-A |
PSR320-D |
PSR650-A |
PSR650-D |
PSR650C-12A |
Rated input voltage |
100 VAC to 240 VAC @ 50/60 Hz |
–48 VDC to –60 VDC |
100 VAC to 240 VAC @ 50/60 Hz |
–48 VDC to –60 VDC |
100 VAC to 240 VAC @ 50/60 Hz |
Rated output voltage |
12 VDC |
12 VDC |
12 VDC |
12 VDC |
12 VDC |
Max. input current |
10 A |
11 A |
10 A |
25 A |
10 A |
Max. output current |
25 A |
25 A |
54 A |
12 V: 54 A 3.3 V: 4 A |
54 A |
Max. system output capacity |
300 W |
300 W |
650 W |
650 W |
650 W |
Support for PoE |
No |
No |
No |
No |
No |
Max. PoE output capacity |
N/A |
N/A |
N/A |
N/A |
N/A |
Table 8-7 Power module specifications (2)
Item |
PSR650C-12D |
PSR1200-A |
PSR1200-D |
PSR1400-A |
|
Rated input voltage |
–48 VDC to –60 VDC |
100 VAC to 240 VAC @ 50/60 Hz |
–48 VDC to –60 VDC |
100 VAC to 240 VAC @ 50/60 Hz |
|
110 V |
220 V |
||||
Rated output voltage |
12 VDC |
· 12 VDC · 3.3 VDC |
· 12 VDC · 3.3 VDC |
12 VDC |
12 VDC |
Max. input current |
25 A |
16 A |
42 A |
16 A |
16 A |
Max. output current |
54 A |
· 100 A (12 V) · 4 A (3.3 V) |
· 100 A (12 V) · 4 A (3.3 V) |
96 A |
117 A |
Max. system output capacity |
650 W |
1213 W |
1213 W |
1150 W |
1400 W |
Support for PoE |
No |
No |
No |
No |
|
Max. PoE output capacity |
N/A |
N/A |
N/A |
N/A |
N/A |
Table 8-8 Power module specifications (3)
Item |
PSR1400-D |
PSR1400-12D1 |
PSR2500-12AHD |
PSR2500-12D |
|
Rated input voltage |
–48 VDC to –60 VDC |
–48 VDC to –60 VDC |
· 100 VAC to 240 VAC @ 50/60 Hz · 240 to 380 VDC |
–48 VDC to –60 VDC |
|
Rated output voltage |
· 12 VDC · PoE: 48 VDC |
12 VDC |
12 VDC |
12 VDC |
|
Max. input current |
190 A |
50 A |
16 A |
85 A |
|
Max. output current |
· 12 VDC: 117 A · PoE: 140 A |
117 A |
90 to 180 VAC: 100 A |
180 to 290 VAC or 180 to 400 VDC: 208 A |
208 A |
Max. system output capacity |
1400 W |
1400 W |
1200 W |
2500 W |
2500 W |
Support for PoE |
Yes |
No |
No |
No |
|
Max. PoE output capacity |
6720 W |
N/A |
N/A |
N/A |
Table 8-9 Power module specifications (4)
Item |
PSR2800-ACV |
PSR6000-ACV |
||
Rated input voltage |
100 VAC to 240 VAC @ 50/60 Hz |
100 VAC to 240 VAC @ 50/60 Hz |
||
110 V |
220 V |
110 V |
220 V |
|
Rated output voltage |
· 12 VDC · PoE: 48 VDC |
· 12 VDC · PoE: 48 VDC |
· 12 VDC · PoE: 48 VDC |
· 12 VDC · PoE: 48 VDC |
Max. input current |
A maximum of 16 A per input |
A maximum of 16 A per input |
A maximum of 16 A per input |
A maximum of 16 A per input |
Max. output current |
· 12 VDC: 96 A · PoE: 23 A |
· 12 VDC: 117 A · PoE: 28 A |
· 12 VDC: 96 A · One PoE input: 23 A · Two PoE inputs: 46 A · Three PoE inputs: 69 A |
· 12 VDC: 117 A · One PoE input: 34 A · Two PoE inputs: 68 A · Three PoE inputs: 100 A |
Max. system output capacity |
1150 W |
1400 W |
1150 W |
1400 W |
Support for PoE |
Yes |
Yes |
||
Max. PoE output capacity |
1150 W |
1400 W |
· One PoE input: 1200 W · Two PoE inputs: 2400 W · Three PoE inputs: 3600 W |
· One PoE input: 1800 W · Two PoE inputs: 3600 W · Three PoE inputs: 5300 W |
|
NOTE: The maximum PoE output power is 10000 W when the device is fully configured with the PSR1400-D or PSR6000-ACV power modules. |
Table 8-10 Power module and chassis compatibility matrix
Power module |
Chassis |
||||||||
S7502E |
S7503E-S |
S7503E-M |
S7503E |
S7506E-S |
S7506E/S7506E-MF |
S7506E (non-PoE)/S7506E-MF (non-PoE) |
S7506E-V |
S7510E |
|
PSR320-A |
l |
l |
l |
— |
— |
— |
— |
— |
— |
PSR320-D |
l |
l |
— |
— |
— |
— |
— |
— |
— |
PSR650-A |
l |
l |
l |
¡ |
¡ |
¡ |
¡ |
¡ |
¡ |
PSR650-D |
l |
l |
l |
¡ |
¡ |
¡ |
¡ |
¡ |
¡ |
PSR650C-12A |
— |
— |
— |
l |
— |
l |
l |
l |
— |
PSR650C-12D |
— |
— |
— |
l |
— |
l |
l |
l |
— |
PSR1200-A |
— |
— |
— |
¡ |
— |
¡ |
¡ |
¡ |
¡ |
PSR1200-D |
— |
— |
— |
¡ |
— |
¡ |
¡ |
¡ |
¡ |
PSR1400-A |
— |
— |
— |
l |
l |
l |
l |
l |
l |
PSR1400-D |
— |
— |
— |
l |
l |
l |
l |
l |
l |
PSR1400-12D1 |
— |
— |
— |
l |
l |
l |
l |
l |
l |
PSR2500-12AHD |
— |
— |
— |
l |
— |
l |
l |
l |
l |
PSR2500-12D |
— |
— |
— |
l |
— |
l |
l |
l |
l |
PSR2800-ACV |
— |
— |
— |
l |
l |
l |
— |
l |
l |
PSR6000-ACV |
— |
— |
— |
l |
l |
l |
— |
l |
l |
|
NOTE: · "l" indicates that the power module can be directly installed on the chassis. · "¡" indicates that you must first install a power module adapter on the chassis and then install the power module on the power module adapter. For more information about installing a power module and a power module adapter, see "Installing the power supply system." · "—" indicates that the power module cannot be installed on the chassis. |
Power cords
DC power cords
A DC power cord connects a DC power module to an external DC power source.
Table 8-11 DC power cords available for DC power modules
DC power cord code |
DC power cord length |
DC power module |
0404A06T |
3 m (9.84 ft) |
PSR320-D/PSR650-D/PSR650C-12D |
0404A01N |
5 m (16.40 ft) |
|
0404A01P |
10 m (32.81 ft) |
|
0404A073 |
20 m (65.62 ft) |
|
0404A0DU |
3 m (9.84 ft) |
PSR1200-D |
0404A07G |
3 m (9.84 ft) |
PSR1400-D/PSR1400-12D1/PSR2500-12D |
0404A08T |
10 m (32.81 ft) |
|
0404A08U |
20 m (65.62 ft) |
|
0404A072 |
25 m (82.02 ft) |
|
0404A0RL |
3 m (9.84 ft) |
PSR2500-12AHD (240 to 380 VDC) |
AC power cords
AC power cords are used for connecting the power modules of an S7500E switch to the external AC power supply system. Before you order an AC power cord, make sure you have read the following restrictions and guidelines:
· Select AC power cords according to the power of the power module.
· The connector type varies by country or region. Select a compliant connector type as needed.
· For the PSR320-A, PSR650-A, and PSR650C-12A power modules, select 10A AC power cords. For the connector types of different countries or regions, see Table 8-12.
· For the PSR1200-A, PSR1400-A, PSR2500-12AHD, PSR2800-ACV, and PSR6000-ACV power modules, select 16A AC power cords. For the connector types of different countries or regions, see Table 8-13. For the PSR2500-12AHD power module, select the 0404A0RP or 0404A0RQ AC power cord. The 0404A0RP and 0404A0RQ AC power cords can only be used for the PSR2500-12AHD power module.
Table 8-12 10A AC power cords used in different countries or regions
1 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
I type |
04041104: 3 m (9.8 ft) |
Mainland China |
|
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
2 |
Connector type |
Code (Length) |
Countries or regions where the type of power cables conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
B type |
04020728: 3 m (9.8 ft) |
Canada and U.S.A |
Mexico, Argentina, Brazil, Columbia, Venezuela, Thailand, Peru, Philippine, and A6 countries or regions |
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
3 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
F type |
04041056: 3 m (9.8 ft) |
Holland, Denmark, Sweden, Finland, Norway, Germany, France, Austria, Belgium, and Italy |
Indonesia, Turkey, Russia, and CIS |
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
4 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
G type |
04040890: 3 m (9.8 ft) |
U.K. |
Malaysia, Hong Kong, and Egypt |
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
5 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
B type |
04040887: 3 m (9.8 ft) |
Japan |
|
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
6 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
I type |
04040888: 3 m (9.8 ft) |
Australia |
|
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
7 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
J type |
04041119: 3 m (9.8 ft) |
Switzerland |
|
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
8 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
L type |
04041120: 3 m (9.8 ft) |
Italy |
|
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
9 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||
D type |
0404A0Q0: 3 m (9.8 ft) |
India |
|
|
|||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||
|
|
|
|||||||||
|
NOTE: The connector outline figures shown in Table 8-12 are connectors for connecting the device. |
Table 8-13 16A AC power cords used in different countries or regions
1 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
I type |
04043396: 3 m (9.8 ft) |
Mainland China |
|
|
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
2 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
C20 type |
0404A0C2: 3 m (9.8 ft) |
Mainland China |
N/A |
N/A |
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
3 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
N/A |
0404A0RP: 3 m (9.8 ft) |
Mainland China |
N/A |
N/A |
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
4 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
I type |
0404A0RQ: 3 m (9.8 ft) |
Mainland China |
N/A |
N/A |
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
5 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
B type |
0404A063: 3 m (9.8 ft) |
Canada and U.S.A |
Mexico, Argentina, Brazil, Columbia, Venezuela, Thailand, Peru, Philippine, and A6 countries or regions |
|
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
6 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
F type |
0404A061: 3 m (9.8 ft) |
Holland, Denmark, Sweden, Finland, Norway, Germany, France, Austria, Belgium, and Italy |
Indonesia, Turkey, Russia, and CIS |
|
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
7 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
B type |
0404A062: 3 m (9.8 ft) |
Japan |
|
|
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
8 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
I type |
0404A01A: 3 m (9.8 ft) |
Australia |
|
|
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
9 |
Connector type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||||||||||||||||||||
D type |
0404A01A: 3 m (9.8 ft) |
India |
|
|
|||||||||||||||||||||
Connector outline |
Power cord outline |
Connector outline |
|||||||||||||||||||||||
|
|
|
|||||||||||||||||||||||
|
NOTE: The connector outline figures shown in Table 8-13 are connectors for connecting devices. |
PoE power system
PoE DC power cords
PoE DC power cords are used to connect the PoE PEM of the switch and the PoE external power frame.
Table 8-14 PoE DC power cord specifications
DC power module |
PoE DC power cord |
Cable length |
PSR2800-ACV/PSR6000-ACV |
0404A05U |
1 m (3.28 ft) |
PSR1400-D |
0404A07H |
3 m (9.84 ft) |
PoE AC power cords
The S7500E switch uses 16 A PoE AC power cords. PoE AC power cords are used to connect the PoE AC PEM held in the PoE external power frame and the external AC power source. The connector type varies by country or region. For more information, see Table 8-13.
Fan trays
The fans trays are shipped with the S7500E switches, and have been installed in the S7500E switches. If the fan tray of a switch fails, order a compatible fan tray to replace the faulty one.
Table 8-15 shows the available fan trays for different models of S7500E switches.
Table 8-15 Fan tray specifications
Fan tray |
Number of fan trays |
Number of fans |
Fan diameter |
Maximum air flow rate |
S7502E fan tray |
1 |
3 |
92 mm (3.62 in) |
165 CFM |
S7503E-S fan tray |
1 |
3 |
92 mm (3.62 in) |
165 CFM |
S7503E-M fan tray |
1 |
3 |
92 mm (3.62 in) |
165 CFM |
S7503E fan tray |
1 |
6 |
92 mm (3.62 in) |
330 CFM |
S7506E-S fan tray |
1 |
9 |
92 mm (3.62 in) |
495 CFM |
S7506E fan tray |
1 |
9 |
92 mm (3.62 in) |
495 CFM |
S7506E (non-PoE) fan tray |
1 |
9 |
92 mm (3.62 in) |
495 CFM |
S7506E-MF fan tray |
3 |
1 small fan + 2 large fans |
· Small fan: 80 mm (3.15 in) · Large fan: 92 mm (3.62 in) |
150 CFM |
S7506E-MF (non-PoE) fan tray |
3 |
1 small fan + 2 large fans |
· Small fan: 80 mm (3.15 in) · Large fan: 92 mm (3.62 in) |
150 CFM |
S7506E-V fan tray |
1 |
6 |
120 mm (4.72 in) |
546 CFM |
S7510E fan tray |
1 |
6 |
92 mm (3.62 in) |
662 CFM |
4 |
120 mm (4.72 in) |
662 CFM |