- Table of Contents
-
- H3C SecPath M9000 Multi Service Security Gateway Series Installation Guides-6W106
- 00-Preface
- 01-Chapter 1 Chassis views
- 01-Chapter 1 Preparing for Installation
- 02-Chapter 2 Installing the Gateway
- 03-Chapter 3 Logging in to the Gateway and Configuring Basic Settings
- 04-Chapter 4 Troubleshooting
- 06-Chapter 6 Replacing FRUs
- 07-Appendix A FRUs and Compatibility Matrixes
- 08-Appendix B Technical Specifications
- 09-Appendix C LEDs
- 10-Appendix D Slot arrangement and interface numbering
- 11-Appendix E Cables
- 12-Appendix F Cabling Recommendations
- 13-Appendix G Repackaging the Gateway
- Related Documents
-
Title | Size | Download |
---|---|---|
07-Appendix A FRUs and Compatibility Matrixes | 66.66 KB |
Appendix A FRUs and compatibility matrixes
For compatibility between the gateway and the cards and transceiver modules, see the release notes.
MPUs
MPU is the core of the control management plane for the gateway. You can install one MPU, or two MPUs in 1+1 redundancy for the gateway. Table 1 shows the MPUs available for the M9000 gateway series.
Table 1 MPU and gateway compatibility
MPU model |
Applicable gateways |
NSQ1SUPB0 |
M9006/M9010/M9010-GM/M9014 |
NSQM1SUPD0 |
M9016-V |
For more information about the MPUs, see the card manuals that come with the MPUs..
Switching fabric modules
The switching fabric modules are the core of the switching plane of the gateway. Table 2 describes the compatibility matrix between the M9000 gateways and switching fabric module models.
Table 2 Switching fabric module and gateway compatibility
Switching fabric module model |
Applicable gateways |
NSQ1FAB04B0 |
M9006 |
NSQ1FAB08D0 |
M9010 M9010-GM M9016-V (supported in R9153P34 and later versions) |
NSQ1FAB12D0 |
M9014 |
NSQM1FAB08E0 |
M9016-V |
Service modules
The gateway supports SC service modules, FG service modules, and security situation intelligent computer node modules. The services modules available for the gateway are described in Table 3, Table 4, and Table 5.
Table 3 SC service module and gateway compatibility
SC service module model |
Description |
Applicable gateways |
NSQM1GMDSCA1 |
Network data encryption module |
M9010-GM |
NSQ1FWCEA0 |
Firewall module |
M9006/M9010/M9014 |
Table 4 FG service module and gateway compatibility
FG service module model |
Description |
Applicable gateways |
NSQM1FWEFGA0 |
Firewall module |
M9006/M9010/M9014/M9016-V |
NSQM1FWDFGB0 |
Firewall module |
|
NSQM1FWDFG0 |
Firewall module |
|
NSQM1FWDFGA1 |
Firewall module |
M9006/M9010/M9014 |
NSQM1FWDFGB1 |
Firewall module |
|
NSQM1FWDFGC1 |
Firewall module |
|
NSQM1FWDFGC0 |
Firewall module |
|
NSQM1FWDFGD1 |
Firewall module |
|
NSQM1NATDFGA0 |
NAT module |
|
NSQM1NATDFGB0 |
NAT module |
|
NSQM1ADEDFGA0 |
Application delivery engine |
|
NSQM1AFC2000GDFGA0 |
Anomaly flow cleaner module |
Table 5 Compatibility between other service modules and the gateway
Service module model |
Description |
Applicable gateways |
NSQM1SSICASK1 |
Security situation intelligent computer node module |
M9006/M9010/M9014 |
NSQM1AIASKA1 |
Security engine module |
For more information about the service modules, see the card manuals that come with the service modules.
Interface modules and interface subcards
The interface modules available for the gateway are described in Table 6.
Table 6 Interface module and gateway compatibility
Interface module model |
Applicable gateways |
NSQ1TGS8EA0 |
M9006/M9010/M9010-GM/M9014 |
NSQ1GT48EA0 |
|
NSQ1GP24TXEA0 |
|
NSQ1TGX4EA0 |
|
NSQ1GP48EB0 |
|
NSQ1TGS32SF0 |
M9006/M9010/M9010-GM/M9014/M9016-V |
NSQ1QGS4SF0 |
|
NSQ1CGC2SE0 |
|
NSQM1TGS32QSSG0 |
|
NSQM1CGQ6SH0 |
|
NSQM1CGQ4TG24SHA0 |
M9006/M9010/M9014/M9016-V |
The interface subcards are installed in the slots of interface switch modules. Table 7 describes the compatibility between interface switch modules and interface subcards.
Table 7 Compatibility matrix between interface switch modules and interface subcards
Interface subcard model |
Applicable interface switch modules |
NSQM2TG16GP40 |
NSQM1MBFEA0 |
NSQM1CGQ20 |
|
NSQM2QG2TG8GP40 |
|
NSQM2QG2GP40 |
|
NSQM2TG8GP40 |
|
NSQM2QG4GP40 |
For more information about the interface modules and interface subcards, see the card manuals that come with the interface modules and interface subcards.
Interface switch modules
An interface switch module provides two subslots for installing interface subcards. Table 8 describes the compatibility between interface switch modules and interface subcards.
Table 8 Compatibility matrix between interface switch modules and subcards
Interface switch module |
Number of slots |
Available subcards |
Applicable gateways |
NSQM1MBFEA0 |
2 |
· NSQM2TG16GP40 · NSQM1CGQ20 (supported only in slot 2) · NSQM2QG2TG8GP40 · NSQM2QG2GP40 · NSQM2TG8GP40 · NSQM2QG4GP40 |
M9006/M9010/M9010-GM/M9014/M9016-V |
Air filters
CAUTION: Clean air filters periodically (at least once every three months) to guarantee adequate ventilation and avoid over-temperature. |
To prevent dusts from entering the chassis, you can configure air filters for the gateway as needed and install the air filters at the air inlet vents.
The gateway air filters include the M9006 air filter, the M9010 air filter, the M9010-GM air filter, the M9014 air filter, and the M9016-V air filter. Order air filters compatible with your gateway.
Transceiver modules
The gateway supports multiple types of transceiver modules. For the transceiver modules available for the ports on a card, see the card manuals.
Power supplies
The power supplies available for the gateway are described in Table 9.
Table 9 Power supply and gateway compatibility
Power supply model |
Applicable gateways |
PSR2500-12A-A |
M9006/M9010/M9010-GM/M9014/M9016-V |
PSR2400-12D-A |
|
PSR2500B-12AHD-F |
M9016-V |
Power cords
DC power cord
DC power cords are used for connecting the DC power supplies to the external DC power supply system.
Table 10 DC power cord specifications
DC power cord |
Cable length |
Cross-sectional area |
Description |
0404A0E1 |
3 m (9.84 ft) |
13 mm2(0.02 in2) |
Used on the NSQM1DC2400 power supply |
0404A0E2 |
15 m (49.21 ft) |
13 mm2(0.02 in2) |
AC power cord
AC power cords are used for connecting the AC power supplies to the external AC power supply system.
· Select AC power cords according to the power of the power supply.
· The connector type varies by country or region. Select a compliant connector type as needed.
· For the connector types of different countries or regions, see H3C Power Cords & Cables.
Table 11 AC power cord specifications
AC power cord |
Cable length |
Cross-sectional area |
Description |
04043396 |
3 m (9.84 ft) |
3*1.5 mm2 (0.002 in2) |
Used on the NSQM1AC2500 power supply |
HVDC power cord
The M9016-V gateway supports the PSR2500B-12AHD-F power supply. Table 12 describes the available power cords for the power supply.
Table 12 HVDC power cord specifications
HVDC power cord |
Cable length |
Cross-sectional area |
Cable type |
Description |
0404A0RL |
3 m (9.84 ft) |
3*1.5 mm2 (0.002 in2) |
HVDC power cord |
Used for HVDC or AC power supply |
0404A0RP |
3 m (9.84 ft) |
3*1.5 mm2 (0.002 in2) |
PDU AC power cord |
Used for AC power supply |
0404A0RQ |
3 m (9.84 ft) |
3*1.5 mm2 (0.002 in2) |
AC power cord |
Used for AC power supply |