02-Fundamentals

HomeSupportRoutersCR16000-F SeriesReference GuidesMIB CompanionH3C CR16000-F Routers MIB Reference-R8530Pxx-6W10002-Fundamentals
07-HH3C-TELNET-MIB
Title Size Download
07-HH3C-TELNET-MIB 81.04 KB

HH3C-TELNET-MIB

About this MIB

Use this MIB to obtain Telnet server basic information or the notifications sent by the Telnet server.

MIB file name

hh3c-telnet.mib

Root object

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2). hh3cTelnet(249)

Scalar objects

hh3cTelnetsLoginFailedTimes (1.3.6.1.4.1.25506.2.249.1.1.1)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTelnetsLoginFailedTimes (1.3.6.1.4.1.25506.2.249.1.1.1)

accessible-for-notify

Unsigned32

Standard MIB values.

Number of user login failures.

As per the MIB.

 

hh3cTelnetsLoginFailedStatPeriod (1.3.6.1.4.1.25506.2.249.1.1.2)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTelnetsLoginFailedStatPeriod (1.3.6.1.4.1.25506.2.249.1.1.2)

accessible-for-notify

Unsigned32

Standard MIB values.

Statistical period of user login failures.

As per the MIB.

 

Notifications

hh3cTelnetsLoginFailed

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.249.1.2.0.1

A user frequently failed authentication when it logs in to the Telnet server.

Error

Warning

1.3.6.1.4.1.25506.2.249.1.2.0.2 (hh3cTelnetsLoginFailedClear)

ON

 

Notification triggers

This notification might be generated when the number of Telnet login failures reaches the specified upper threshold.

A user might have attempted to log in to the Telnet server for a long time and the attempts have failed.

System impact

The system might be attacked.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.249.1.1.1 (hh3cTelnetsLoginFailedTimes)

Number of user login failures.

N/A

Unsigned32

Standard MIB values.

1.3.6.1.4.1.25506.2.249.1.1.2 (hh3cTelnetsLoginFailedStatPeriod)

Statistical period of user login failures.

N/A

Unsigned32

Standard MIB values.

 

Recommended action

To resolve this issue:

1.Verify that the username and password are correct.

2.Verify that an ACL has been configured to filter invalid addresses.

3.Collect alarm information and configuration data, and then contact H3C Support for help.

hh3cTelnetsLoginFailedClear

Basic information

OID