- Table of Contents
-
- 11-WLAN
- 01-HH3C-DOT11-ROAM-MIB
- 02-HH3C-DOT11-ACMT-MIB
- 03-HH3C-DOT11-APMT-MIB
- 04-HH3C-DOT11-CFG-MIB
- 05-HH3C-DOT11-CFGEXT-MIB
- 06-HH3C-WAPI-MIB
- 07-HH3C-WLAN-FLEXAPP-CFG-MIB
- 08-HH3C-DOT11-WLANEXT-MIB
- 09-HH3C-DOT11-WIPS-MIB
- 10-HH3C-DOT11-STATION-MIB
- 11-HH3C-DOT11-QOS-MIB
- 12-HH3C-DOT11-SA-MIB
- 13-HH3C-DOT11-RRM-MIB
- 14-HH3C-DOT11-SAVI-MIB
- 15-HH3C-DOT11-WM2U-MIB
- 16-HH3C-DOT11-PROBE-MIB
- 17-HH3C-DOT11S-MESH-MIB
- Related Documents
-
Title | Size | Download |
---|---|---|
07-HH3C-WLAN-FLEXAPP-CFG-MIB | 224.92 KB |
Contents
HH3C-WLAN-FLEXAPP-CFG-MIB
About this MIB
Use this MIB to manage IoT service and wireless location settings.
● IoT service settings—IoT module and BLE location settings, and notifications triggered by the access, removal, and type mismatch of an IoT module.
● Wireless location settings—AeroScout location, CUPID location, and RF fingerprinting settings, and shared wireless location settings.
MIB file name
hh3c-wlan-flexapp-cfg.mib
Root object
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cDot11(75).hh3cWlanFlexAppCFG(19)
Tabular objects
hh3cWlanModuleConfigTable
About this table
This table describes the configuration parameters of a module to be configured.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table indexes are hh3cWlanAPSerialID and hh3cWlanModuleID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanAPSerialID(1.3.6.1.4.1.25506.2.75.19.1.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanModuleID(1.3.6.1.4.1.25506.2.75.19.1.1.1.2) |
not-accessible |
Integer32 |
Integer32(1..65535) |
IoT module ID. |
As per the MIB. |
hh3cWlanModuleType(1.3.6.1.4.1.25506.2.75.19.1.1.1.3) |
read-write |
INTEGER |
none(0), ble(1), iot(2) |
IoT module type. |
As per the MIB. |
hh3cWlanModuleStatus(1.3.6.1.4.1.25506.2.75.19.1.1.1.4) |
read-write |
TruthValue |
true(1), false(2) |
Whether the IOT module is enabled. |
As per the MIB. |
hh3cWlanModuleReset(1.3.6.1.4.1.25506.2.75.19.1.1.1.5) |
read-write |
INTEGER |
none(0), reboot(1) |
Reset state of the IoT module. |
As per the MIB. |
hh3cWlanModuleRstFac(1.3.6.1.4.1.25506.2.75.19.1.1.1.6) |
read-write |
INTEGER |
none(0), restore(1) |
Whether to restore the IoT module to factory defaults. |
As per the MIB. |
hh3cWlanModuleUpWareStatus(1.3.6.1.4.1.25506.2.75.19.1.1.1.7) |
read-write |
TruthValue |
true(1), false(2) |
Upgrade state of the IoT module. |
As per the MIB. |
hh3cWlanModuleTxPower(1.3.6.1.4.1.25506.2.75.19.1.1.1.8) |
read-write |
Integer32 |
Integer32(1..4) |
Tx power of the IoT module. |
As per the MIB. |
hh3cWlanModuleManualUpdate(1.3.6.1.4.1.25506.2.75.19.1.1.1.9) |
read-write |
OCTET STRING |
OCTET STRING(0..64) |
Upgrade file path of the IoT module. |
As per the MIB. |
hh3cWlanModuleInfoTable
About this table
This table describes information about each IoT module on an AP.
Support for operations
Create:Not supported
Edit/Modify:Not supported
Delete:Not supported
Read:Supported
Columns
The table indexes are hh3cDot11IOTAPSerialID and hh3cDot11IOTModuleID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cDot11IOTAPSerialID (1.3.6.1.4.1.25506.2.75.19.1.2.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cDot11IOTModuleID (1.3.6.1.4.1.25506.2.75.19.1.2.1.2) |
not-accessible |
Integer32 |
Integer32(1..65535) |
IoT module ID. |
As per the MIB. |
hh3cDot11IOTModuleType (1.3.6.1.4.1.25506.2.75.19.1.2.1.3) |
read-only |
INTEGER |
none(0), h3c(1), iot(2) |
IoT module type. |
As per the MIB. |
hh3cDot11IOTModuleModel(1.3.6.1.4.1.25506.2.75.19.1.2.1.4) |
read-only |
OCTET STRING |
OCTET STRING(0..8) |
IoT module model. |
As per the MIB. |
hh3cDot11IOTModuleHwVersion(1.3.6.1.4.1.25506.2.75.19.1.2.1.5) |
read-only |
OCTET STRING |
OCTET STRING(0..32) |
Hardware version number of the IoT module. |
As per the MIB. |
hh3cDot11IOTModuleSwVersion(1.3.6.1.4.1.25506.2.75.19.1.2.1.6) |
read-only |
OCTET STRING |
OCTET STRING(0..32) |
Software version number of the IoT module. |
As per the MIB. |
hh3cDot11IOTModuleSequenceId(1.3.6.1.4.1.25506.2.75.19.1.2.1.7) |
read-only |
OCTET STRING |
OCTET STRING(0..32) |
Serial number of the IoT module. |
As per the MIB. |
hh3cWlanIOTConfigTable
About this table
This table describes the IP address and port number of an IoT server.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanIOTAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanIOTAPSerialID (1.3.6.1.4.1.25506.2.75.19.2.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanIOTEngineAdd(1.3.6.1.4.1.25506.2.75.19.2.1.1.2 |
read-write |
IpAddress |
Standard MIB values. |
IP address of the server to which the IoT module reports data. |
As per the MIB. |
hh3cWlanIOTEnginePort(1.3.6.1.4.1.25506.2.75.19.2.1.1.3) |
read-write |
Integer32 |
Integer32(0..65535) |
Port number of the server to which the IoT module reports data. |
As per the MIB. |
hh3cWlanBLEConfigTable
About this table
This table describes BLE location settings.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanBLEAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanBLEAPSerialID (1.3.6.1.4.1.25506.2.75.19.4.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanBLEStatus(1.3.6.1.4.1.25506.2.75.19.4.1.1.2) |
read-write |
TruthValue |
true(1), false(2) |
Whether BLE location is enabled. |
As per the MIB. |
hh3cWlanBLEEngineAdd(1.3.6.1.4.1.25506.2.75.19.4.1.1.3) |
read-write |
IpAddress |
Standard MIB values. |
IP address of the UDP server that receives BLE messages. |
As per the MIB. |
hh3cWlanBLEEnginePort(1.3.6.1.4.1.25506.2.75.19.4.1.1.4) |
read-write |
Integer32 |
Integer32(0..65535) |
Port number of the UDP server that receives BLE messages. |
As per the MIB. |
hh3cWlanBLEVendorPort(1.3.6.1.4.1.25506.2.75.19.4.1.1.5) |
read-write |
Integer32 |
Integer32(1..65535) |
UDP port number of the device that receives packets from the BLE server. |
As per the MIB. |
hh3cWlanBLEReportStatus(1.3.6.1.4.1.25506.2.75.19.4.1.1.8 |
read-write |
TruthValue |
true(1), false(2) |
Whether reporting BLE location packets is enabled. |
As per the MIB. |
hh3cWlanBLEReportInterval(1.3.6.1.4.1.25506.2.75.19.4.1.1.9) |
read-write |
Integer32 |
Integer32(1..86400) |
Interval for reporting BLE location packets. |
As per the MIB. |
hh3cWlanBLEAgingTime(1.3.6.1.4.1.25506.2.75.19.4.1.1.10) |
read-write |
Integer32 |
Integer32(60..3600) |
iBeacon device aging time. |
As per the MIB. |
hh3cWlanBLERealTimeReportStatus(1.3.6.1.4.1.25506.2.75.19.4.1.1.11) |
read-write |
TruthValue |
true(1), false(2) |
Whether reporting BLE location packets in real-time is enabled. |
As per the MIB. |
hh3cWlanBLERealTimePrefix(1.3.6.1.4.1.25506.2.75.19.4.1.1.12) |
read-write |
OCTET STRING |
OCTET STRING(0|8..18) |
Manufacturer prefix of BLE devices to be located. |
As per the MIB. |
hh3cWlanBLECommandPassword(1.3.6.1.4.1.25506.2.75.19.4.1.1.13) |
read-write |
OCTET STRING |
OCTET STRING(0|12) |
Command password of the BLE module. |
As per the MIB. |
hh3cWlanBLEConnectPassword(1.3.6.1.4.1.25506.2.75.19.4.1.1.14) |
read-write |
OCTET STRING |
OCTET STRING(0|4) |
Connection password of the BLE module. |
As per the MIB. |
hh3cWlanBLEModuleConfigTable
About this table
This table describes the configuration parameters of a BLE module.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table indexes are hh3cWlanBLEModuleAPSerialID and hh3cWlanBLEModuleID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanBLEModuleAPSerialID (1.3.6.1.4.1.25506.2.75.19.4.2.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanBLEModuleID (1.3.6.1.4.1.25506.2.75.19.4.2.1.2) |
not-accessible |
Integer32 |
Integer32(1..65535) |
BLE module ID. |
As per the MIB. |
hh3cWlanBLEAdvReportStatus (1.3.6.1.4.1.25506.2.75.19.4.2.1.3) |
read-write |
TruthValue |
true(1), false(2) |
Whether reporting broadcast packets is enabled for the BLE module. |
As per the MIB. |
hh3cWlanBLEAdvReportInterval (1.3.6.1.4.1.25506.2.75.19.4.2.1.4) |
read-write |
Integer32 |
Integer32(50..1000) |
Interval for reporting BLE broadcast packets. |
As per the MIB. |
hh3cWlanBLEAdvUUID (1.3.6.1.4.1.25506.2.75.19.4.2.1.5) |
read-write |
OCTET STRING |
OCTET STRING(0|32) |
UUID of BLE broadcast packets. |
As per the MIB. |
hh3cWlanBLEAdvMajorID (1.3.6.1.4.1.25506.2.75.19.4.2.1.6) |
read-write |
Integer32 |
Integer32(0..65535) |
Major ID of BLE broadcast packets. |
As per the MIB. |
hh3cWlanBLEAdvMinorID (1.3.6.1.4.1.25506.2.75.19.4.2.1.7) |
read-write |
Integer32 |
Integer32(0..65535) |
Minor ID of BLE broadcast packets. |
As per the MIB. |
hh3cWlanAEConfigTable
About this table
Use this table to obtain and modify AeroScout location settings.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanAEAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanAEAPSerialID (1.3.6.1.4.1.25506.2.75.19.5.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanAEStatus (1.3.6.1.4.1.25506.2.75.19.5.1.1.2) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of AeroScout location. |
As per the MIB. |
hh3cWlanAEEngineAddr (1.3.6.1.4.1.25506.2.75.19.5.1.1.3) |
read-write |
IPAddress |
Standard MIB values. |
IPv4 address of the AeroScout location server. |
As per the MIB. |
hh3cWlanAEEnginePort (1.3.6.1.4.1.25506.2.75.19.5.1.1.4) |
read-write |
Integer32 |
Integer32(0..65535) |
Port number of the AeroScout location server. |
As per the MIB. |
hh3cWlanAEVendorPort (1.3.6.1.4.1.25506.2.75.19.5.1.1.5) |
read-write |
Integer32 |
Integer32(1..65535) |
Port to which the AP listens for messages from the AeroScout location server. |
As per the MIB. |
hh3cWlanAETimeStamp (1.3.6.1.4.1.25506.2.75.19.5.1.1.6) |
read-write |
INTEGER |
absolute(1), relative(2) |
Type of timestamps to be encapsulated in MU packets. |
As per the MIB. |
hh3cWlanAEVersion (1.3.6.1.4.1.25506.2.75.19.5.1.1.7) |
read-write |
INTEGER |
v2(2), v3(3) |
AE version. |
As per the MIB. |
hh3cWlanAETagMultiAddr (1.3.6.1.4.1.25506.2.75.19.5.1.1.8) |
read-write |
MacAddress |
OCTET STRING(6) |
Multicast MAC address for Tags. |
As per the MIB. |
hh3cWlanAEEngineDetection (1.3.6.1.4.1.25506.2.75.19.5.1.1.9) |
read-write |
INTEGER |
static(1), dynamic(2) |
AeroScout location mode. |
As per the MIB. |
hh3cWlanAEReportMode (1.3.6.1.4.1.25506.2.75.19.5.1.1.10) |
read-write |
INTEGER |
local(1), central(2) |
Report mode for AeroScout location packets. |
As per the MIB. |
hh3cWlanAERadioConfigTable
About this table
Use this table to obtain and modify radio settings for AeroScout location.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanAERadioAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanAERadioAPSerialID (1.3.6.1.4.1.25506.2.75.19.5.2.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanAEAPRadioID (1.3.6.1.4.1.25506.2.75.19.5.2.1.2) |
not-accessible |
Integer32 |
Integer32(1..65535) |
Radio ID. |
As per the MIB. |
hh3cWlanAERadioStatus (1.3.6.1.4.1.25506.2.75.19.5.2.1.3) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of the radio for AeroScout location. |
As per the MIB. |
hh3cWlanAEMUStatus (1.3.6.1.4.1.25506.2.75.19.5.2.1.4) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of reporting MU messages. |
As per the MIB. |
hh3cWlanAETagStatus (1.3.6.1.4.1.25506.2.75.19.5.2.1.5) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of reporting Tag messages. |
As per the MIB. |
hh3cWlanCommonConfigTable
About this table
Use this table to obtain and modify shared wireless location settings.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanCommonAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanCommonAPSerialID (1.3.6.1.4.1.25506.2.75.19.6.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanDilutionStatus (1.3.6.1.4.1.25506.2.75.19.6.1.1.2) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of packet dilution. |
As per the MIB. |
hh3cWlanDilutionFactor (1.3.6.1.4.1.25506.2.75.19.6.1.1.3) |
read-write |
Integer32 |
Integer32(0..10000) |
Packet dilution factor. |
As per the MIB. |
hh3cWlanDilutionTimeout (1.3.6.1.4.1.25506.2.75.19.6.1.1.4) |
read-write |
Integer32 |
Integer32(0..60) |
Dilution timeout timer, in seconds. |
As per the MIB. |
hh3cWlanIgnoreBeacon (1.3.6.1.4.1.25506.2.75.19.6.1.1.5) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of beacon frame filtering. |
As per the MIB. |
hh3cWlanRateLimitStatus (1.3.6.1.4.1.25506.2.75.19.6.1.1.6) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of location packet rate limiting for the AP. |
As per the MIB. |
hh3cWlanRateLimitCir (1.3.6.1.4.1.25506.2.75.19.6.1.1.7) |
read-write |
Integer32 |
Integer32(0|8..1300000) |
CIR of location packets for the AP, in Kbps. |
As per the MIB. |
hh3cWlanRateLimitCbs (1.3.6.1.4.1.25506.2.75.19.6.1.1.8) |
read-write |
Integer32 |
Integer32(0|500..130000000) |
CBS of location packets for the AP, in bytes. |
As per the MIB. |
hh3cWlanClientRateLimitStatus (1.3.6.1.4.1.25506.2.75.19.6.1.1.9) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of client location packet rate limiting. |
As per the MIB. |
hh3cWlanClientRateLimitCir (1.3.6.1.4.1.25506.2.75.19.6.1.1.10) |
read-write |
Integer32 |
Integer32(0..1300000) |
CIR of client location packets, in Kbps. |
As per the MIB. |
hh3cWlanClientRateLimitCbs (1.3.6.1.4.1.25506.2.75.19.6.1.1.11) |
read-write |
Integer32 |
Integer32(0|80..130000000) |
CBS of client location packets, in bytes. |
As per the MIB. |
hh3cWlanRssiStatus (1.3.6.1.4.1.25506.2.75.19.6.1.1.12) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of RSSI limiting. |
As per the MIB. |
hh3cWlanRssiThreshold (1.3.6.1.4.1.25506.2.75.19.6.1.1.13) |
read-write |
Integer32 |
Integer32(5..100) |
RSSI threshold for client packets. |
As per the MIB. |
hh3cWlanIgnoreApFrame (1.3.6.1.4.1.25506.2.75.19.6.1.1.14) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of packet filtering for the AP. |
As per the MIB. |
hh3cWlanCUPIDConfigTable
About this table
Use this table to obtain and modify CUPID location settings.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanCupidAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanCupidAPSerialID (1.3.6.1.4.1.25506.2.75.19.7.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanCupidStatus (1.3.6.1.4.1.25506.2.75.19.7.1.1.2) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of CUPID location. |
As per the MIB. |
hh3cWlanCupidEngineAddr (1.3.6.1.4.1.25506.2.75.19.7.1.1.3) |
read-write |
IpAddress |
Standard MIB values. |
IPv4 address of the CUPID location server. |
As per the MIB. |
hh3cWlanCupidEnginePort (1.3.6.1.4.1.25506.2.75.19.7.1.1.4) |
read-write |
Integer32 |
Integer32(0..65535) |
Port number of the CUPID location server. |
As per the MIB. |
hh3cWlanCupidVendorPort (1.3.6.1.4.1.25506.2.75.19.7.1.1.5) |
read-write |
Integer32 |
Integer32(1..65535) |
Port to which the AP listens for messages from the CUPID location server. |
As per the MIB. |
hh3cWlanCupidReportStatus (1.3.6.1.4.1.25506.2.75.19.7.1.1.6) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of client list reporting. |
As per the MIB. |
hh3cWlanCupidReportInterval (1.3.6.1.4.1.25506.2.75.19.7.1.1.7) |
read-write |
Integer32 |
Integer32(1..10) |
Interval for sending client list reports. |
As per the MIB. |
hh3cWlanCupidUnassSta (1.3.6.1.4.1.25506.2.75.19.7.1.1.8) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of unassociated client information reporting. |
As per the MIB. |
hh3cWlanCupidUnassMeasureSta (1.3.6.1.4.1.25506.2.75.19.7.1.1.9) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of unassociated client location. |
As per the MIB. |
hh3cWlanCupidReportMode (1.3.6.1.4.1.25506.2.75.19.7.1.1.10) |
read-write |
INTEGER |
local(1), central(2) |
Report mode for CUPID location packets. |
As per the MIB. |
hh3cWlanCUPIDReportFormat (1.3.6.1.4.1.25506.2.75.19.7.1.1.11) |
read-write |
INTEGER |
general(1), lightweight(2) |
Location packet format for CUPID location. |
As per the MIB. |
hh3cWlanFPConfigTable
About this table
Use this table to obtain and modify the RF fingerprinting settings.
Support for operations
Create:Not supported
Edit/Modify:Supported
Delete:Not supported
Read:Supported
Columns
The table index is hh3cWlanFPAPSerialID.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
hh3cWlanFPAPSerialID (1.3.6.1.4.1.25506.2.75.19.8.1.1.1) |
not-accessible |
OCTET STRING |
OCTET STRING(0..127) |
AP serial number. |
As per the MIB. |
hh3cWlanFPStatus (1.3.6.1.4.1.25506.2.75.19.8.1.1.2) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of RF fingerprinting. |
As per the MIB. |
hh3cWlanFPEngineAddr (1.3.6.1.4.1.25506.2.75.19.8.1.1.3) |
read-write |
IpAddress |
Standard MIB values. |
IPv4 address of the RF fingerprinting server. |
As per the MIB. |
hh3cWlanFPEnginePort (1.3.6.1.4.1.25506.2.75.19.8.1.1.4) |
read-write |
Integer32 |
Integer32(0..65535) |
Port number of the RF fingerprinting server. |
As per the MIB. |
hh3cWlanFPVendorPort (1.3.6.1.4.1.25506.2.75.19.8.1.1.5) |
read-write |
Integer32 |
Integer32 (1..65535) |
Port to which the AP listens for messages from the RF fingerprinting server. |
As per the MIB. |
hh3cWlanFPRawFrameReport (1.3.6.1.4.1.25506.2.75.19.8.1.1.6) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of raw frame reporting. |
As per the MIB. |
hh3cWlanFPMUReport (1.3.6.1.4.1.25506.2.75.19.8.1.1.7) |
read-write |
TruthValue |
enable(1), disable(2) |
Enabling status of MU information reporting. |
As per the MIB. |
hh3cWlanFPReportMode (1.3.6.1.4.1.25506.2.75.19.8.1.1.8) |
read-write |
INTEGER |
local(1), central(2) |
Report mode for RF fingerprinting packets. |
As per the MIB. |
hh3cWlanFPReportFormat (1.3.6.1.4.1.25506.2.75.19.8.1.1.9) |
read-write |
INTEGER |
general(1), lightweight(2), cupidhybrid(3) |
Location packet format for RF fingerprinting. |
As per the MIB. |
hh3cWlanFPTagMultiAddr (1.3.6.1.4.1.25506.2.75.19.8.1.1.10) |
read-write |
MacAddress |
OCTET STRING (6) |
Multicast MAC address for Tags. |
As per the MIB. |
Notifications
hh3cWlanModuleInsertTrap
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.75.19.3.0.1 |
An IoT module is inserted. |
Informational |
Warning |
N/A (N/A) |
OFF |
Notification triggers
This notification is generated when an IoT module comes online.
System impact
No negative impact on services.
Status control
ON
CLI: Use the snmp-agent trap enable wlan location-aware command.
OFF
CLI: Use the undo snmp-agent trap enable wlan location-aware command.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.75.19.3.1.1 (hh3cWlanTrapAPMacAddress) |
MAC address of the AP. |
N/A |
MacAddress |
OCTET STRING (6) |
1.3.6.1.4.1.25506.2.75.19.3.1.2 (hh3cWlanTrapModuleID) |
ID of the inserted module. |
N/A |
Integer32 |
Integer32(1..255) |
1.3.6.1.4.1.25506.2.75.19.3.1.4 (hh3cWlanTrapModulePhyType) |
Physical type of the IoT module. |
N/A |
INTEGER |
None(0), h3c(1), iot(2) |
1.3.6.1.4.1.25506.2.75.19.3.1.5 (hh3cWlanTrapModuleModel) |
IoT module model. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
1.3.6.1.4.1.25506.2.75.19.3.1.6 (hh3cWlanTrapModuleHwVersion) |
Hardware version number of the IoT module. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
1.3.6.1.4.1.25506.2.75.19.3.1.7 (hh3cWlanTrapModuleSwVersion) |
Software version number of the IoT module. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
1.3.6.1.4.1.25506.2.75.19.3.1.8 (hh3cWlanTrapModuleSequenceId) |
Hardware serial number of the IoT module. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
Recommended action
No action is required.
hh3cWlanModuleRomveTrap
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.75.19.3.0.2 |
An IoT module is moved. |
Informational |
Warning |
N/A (N/A) |
OFF |
Notification triggers
This notification is generated when an IoT module is removed.
System impact
No negative impact on services.
Status control
ON
CLI: Use the snmp-agent trap enable wlan location-aware command.
OFF
CLI: Use the undo snmp-agent trap enable wlan location-aware command.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.75.19.3.1.1 (hh3cWlanTrapAPMacAddress) |
MAC address of the AP. |
N/A |
MacAddress |
OCTET STRING (6) |
1.3.6.1.4.1.25506.2.75.19.3.1.2 (hh3cWlanTrapModuleID) |
ID of the inserted module. |
N/A |
Integer32 |
Integer32(1..255) |
1.3.6.1.4.1.25506.2.75.19.3.1.4 (hh3cWlanTrapModulePhyType) |
Physical type of the IoT module. |
N/A |
INTEGER |
None(0), h3c(1), iot(2) |
1.3.6.1.4.1.25506.2.75.19.3.1.5 (hh3cWlanTrapModuleModel) |
IoT module model. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
1.3.6.1.4.1.25506.2.75.19.3.1.6 (hh3cWlanTrapModuleHwVersion) |
Hardware version number of the IoT module. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
1.3.6.1.4.1.25506.2.75.19.3.1.7 (hh3cWlanTrapModuleSwVersion) |
Software version number of the IoT module. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
1.3.6.1.4.1.25506.2.75.19.3.1.8 (hh3cWlanTrapModuleSequenceId) |
Hardware serial number of the IoT module. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
Recommended action
No action is required.
hh3cWlanModuleMissMatch
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.75.19.3.0.3 |
The physical type of an IoT module does not match the configured type. |
Informational |
Warning |
N/A (N/A) |
OFF |
Notification triggers
This notification is generated when the physical type and configured type of an IoT module are inconsistent.
System impact
The IoT module cannot operate correctly.
Status control
ON
CLI: Use the snmp-agent trap enable wlan location-aware command.
OFF
CLI: Use the undo snmp-agent trap enable wlan location-aware command.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.75.19.3.1.1 (hh3cWlanTrapAPMacAddress) |
MAC address of the AP. |
N/A |
MacAddress |
OCTET STRING (6) |
1.3.6.1.4.1.25506.2.75.19.3.1.2 (hh3cWlanTrapModuleID) |
ID of the inserted module. |
N/A |
Integer32 |
Integer32(1..255) |
1.3.6.1.4.1.25506.2.75.19.3.1.3 (hh3cWlanTrapModuleCfgType) |
Configured type of the IoT module. |
N/A |
INTEGER |
none(0), h3c(1), iot(2) |
1.3.6.1.4.1.25506.2.75.19.3.1.4 (hh3cWlanTrapModulePhyType) |
Physical type of the IoT module. |
N/A |
INTEGER |
None(0), h3c(1), iot(2) |
1.3.6.1.4.1.25506.2.75.19.3.1.5 (hh3cWlanTrapModuleModel) |
IoT module model. |
N/A |
OCTET STRING |
OCTET STRING (0..32) |
Recommended action
Verify that the configured type of the IoT module matches its physical type.