H3C G3G5 Servers Storage Controller User Guide-6W108

HomeSupportConfigure & DeployUser ManualsH3C G3G5 Servers Storage Controller User Guide-6W108
05-Configuring a P430 storage controller
Title Size Download
05-Configuring a P430 storage controller 5.55 MB

Configuring a RAID-P430-M1 or RAID-P430-M2 storage controller

 

NOTE:

The BIOS screens might vary by the BIOS version. The screenshots in this chapter are for illustration only.

 

About RAID-P430-M1 and RAID-P430-M2 storage controllers

The RAID-P430-M1 and RAID-P430-M2 storage controllers support 6-Gbps and 12-Gbps SAS/SATA data channels and caching, which greatly increases performance and data security. For more information about storage controller details and the supported cache, access http://www.h3c.com/en/home/qr/default.htm?id=66.

Features

Operating modes

The storage controller supports the following operating modes:

·     RAID: expose raw modeThis is the default mode. In this mode, the system can identify and assign drive letters to both raw drives and member drives of RAID arrays.

·     RAID: hide raw modeIn this mode, the system can identify and assign drive letters only to member drives of RAID arrays. Raw drives cannot be identified or used by the operating system.

·     HBA mode—In this mode, physical drives are exposed as raw drives and RAID functions are disabled.

·     Auto Volume mode—In this mode, physical drives with system partitions are exposed as raw drives. Physical drives without system partitions are configured as simple volumes.

·     Simple Volume mode—In this mode, only non-redundant RAID arrays with the simple volume level (each contains only one drive) can be created. RAID arrays with other RAID levels cannot be created.

 

 

NOTE:

Raw drives refer to drives that do not have RAID configuration.

 

Before you configure RAID in RAID: expose raw or RAID: hide raw mode or set the controller operating mode to auto volume or simple volume mode, you must initialize target drives.

Before you configure the controller to operate in RAID: expose raw mode without RAID configuration or in HBA mode, you must uninitialize target drives.

For the new mode to take effect, restart the server after an operating mode change.

The operating system might fail to start up after the operating mode of the storage controller is changed. To resolve the issue, you can re-install the operating system. If the issue persists, contact Technical Support.

RAID levels

The supported RAID levels vary by storage controller model. For more information about the supported RAID levels of each storage controller, contact Technical Support.

Table 1 shows the minimum number of drives required by each RAID level and the maximum number of failed drives supported by each RAID level. For more information about RAID levels, see "Appendix B  RAID arrays and fault tolerance."

Table 1 RAID levels and the numbers of drives for each RAID level

RAID level

Min. drives required

Max. failed drives

RAID 0

2

0

RAID 1

2

1

RAID 1E

3

1

RAID 5

3

1

RAID 6

4

2

RAID 10

4

n, where n is the number of RAID 1 arrays in the RAID 10 array.

RAID 50

6

n, where n is the number of RAID 5 arrays in the RAID 50 array.

RAID 60

8

2n, where n is the number of RAID 6 arrays in the RAID 60 array.

Simple Volume

1

0

 

Hot spare drives

You can configure hot spare drives to improve data security. A hot spare drive is a standby drive that does not store any data. When one or multiple drives in a redundant RAID fails, spare drives automatically replace the failed drives and rebuild the data of the failed drives.

The storage controller supports the following types of hot spare drives. For more information about hot spare drive types, see "Storage controller features."

·     Global spare drive.

·     Dedicated spare drive.

·     Pooled spare drive.

Restrictions and guidelines for configuring RAID

·     As a best practice, configure RAID with drives that do not contain RAID information.

·     To build a RAID successfully and ensure RAID performance, make sure all drives in the RAID are the same type (HDDs or SSDs) and have the same connector type (SAS or SATA).

·     For efficient use of storage, use drives that have the same capacity to build a RAID. If the drives have different capacities, the lowest capacity is used across all drives in the RAID.

·     If you use one physical drive to create multiple RAIDs, RAID performance might decrease in addition to increased maintenance complexities.

High speed read/write cache

For the RAID-P430-M1 and RAID-P430-M2 storage controllers, you can enable caching on the storage controller by using ARCCONF commands. For more information, see "xxx."

Configuring RAID arrays in UEFI mode

This section describes how to configure RAID arrays through a storage controller in UEFI mode. For more information about how to enter the BIOS and set the boot mode to UEFI, see the BIOS user guide for the server.

RAID array configuration tasks at a glance

To configure RAID arrays in UEFI mode, perform the following tasks:

·     Accessing the storage controller configuration screen

·     Switching the storage controller operating mode

·     Scanning drives

·     Initializing drives

·     Configuring RAID arrays

·     (Optional.) Configuring hot spare drives

·     (Optional.) Deleting RAID arrays

·     (Optional.) Uninitializing drives

·     (Optional.) Locating drives

·     (Optional.) Erasing drives

·     (Optional.) Restoring the default configuration for a storage controller

·     (Optional.) Upgrading the storage controller firmware online

·     (Optional.) Enabling RAID rebuilding

·     (Optional.) Migrating RAID levels

·     (Optional.) Expanding RAID capacity

Accessing the storage controller configuration screen

1.     During server POST, press Delete, Esc, or F2 as prompted to open the BIOS setup screen as shown in Figure 1.

For how to navigate screens and modify settings, see the operation instructions at the lower right corner.

Figure 1 BIOS setup screen

 

2.     On the screen as shown in Figure 2, select Advanced > PMC maxView Storage Manager, and press Enter.

Figure 2 Advanced screen

 

3.     On the screen as shown in Figure 3, select Scan For Controllers, and press Enter.

Figure 3 Selecting Scan For Controllers

 

4.     On the screen as shown in Figure 4, select Controller #0 PM8060-RAID, and press Enter.

Figure 4 Selecting Controller #0 PM8060-RAID

 

5.     The storage controller configuration screen as shown in Figure 5 opens. This screen contains tasks as described in Table 2.

Figure 5 Storage controller configuration screen

 

Table 2 Storage controller configuration tasks

Option

Description

Logical Device Configuration

Select Logical Device Configuration to perform the following tasks:

·     Manage RAID arrays.

·     Create RAID arrays.

·     Initialize drives.

·     Erase drives.

·     Configure global hot spare drives.

Controller Settings

Select Controller Settings to perform the following tasks:

·     Modify the storage controller operating mode.

·     View the storage controller configuration information.

·     Restore the default configuration for a storage controller.

Disk Utilities

Select Disk Utilities to perform the following tasks:

·     View physical drive information.

·     Locate physical drives.

·     Format drives.

Administration

Select Administration to update the storage controller firmware.

 

Switching the storage controller operating mode

1.     On the storage controller configuration screen as shown in Figure 6, select Controller Settings, and press Enter.

Figure 6 Storage controller configuration screen

2016-07-27_132918

 

2.     On the screen as shown in Figure 7, select Controller Configuration, and press Enter.

Figure 7 Controller Settings screen

 

3.     On the screen as shown in Figure 8, select Controller Mode, and press Enter.

Figure 8 Controller Configuration screen

 

4.     On the screen as shown in Figure 9, select a storage controller operating mode, and press Enter.

Table 3 describes the storage controller operating modes.

Figure 9 Selecting a storage controller operating mode

 

Table 3 Storage controller operating modes

Operating mode

Description

RAID: expose RAW

All RAID functions can be used. Raw physical drives are exposed to the system.

RAID: hide RAW

All RAID functions can be used. Raw physical drives are not exposed to the system.

HBA

RAID functions are disabled. Raw physical drives are exposed to the system. Before setting this mode, you must delete all RAID arrays and hot spare drives, and perform the Uninitializing drives operation for all drives.

Auto Volume

In this mode, raw physical drives with system partitions are exposed to the system, and physical drives without system partitions are configured as simple volumes. Before setting this mode, you must delete all RAID arrays and hot spare drives in the system.

Simple Volume

In this mode, only non-redundant RAID arrays with the simple volume level (each contains only one drive) can be created. RAID arrays with other RAID levels cannot be created. Before setting this mode, you must delete all RAID arrays and hot spare drives in the system.

 

Scanning drives

The storage controller might fail to timely recognize drives after the drives are hot swapped. To solve this problem, you can scan drives.

To scan drives:

1.     On the storage controller configuration screen as shown in Figure 10, select Logical Device Configuration, and press Enter.

Figure 10 Storage controller configuration screen

 

2.     On the screen as shown in Figure 11, select Rescan Drives, and press Enter to scan drives.

Figure 11 Logical Device Configuration screen

 

Initializing drives

Initializing a drive is to divide a small partition from the drive for saving the RAID information. A raw drive must be initialized before it can be used for creating a RAID array or configured as a hot spare drive.

To initialize drives:

1.     On the storage controller configuration screen as shown in Figure 12, select Logical Device Configuration, and press Enter.

Figure 12 Storage controller configuration screen

 

2.     On the screen as shown in Figure 13, select Initialize Drives, and press Enter.

Figure 13 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 14, select the drives to be initialized. ([Enabled] following a drive means that the drive has been selected.) Then, select SUBMIT and press Enter.

Figure 14 Selecting drives

 

4.     If the system prompts that the initiation will erase all array information from the selected drives and affect RAID arrays using these selected drives, perform one of the following tasks:

¡     To verify if the drives are correctly selected, press ESC to go back to the previous step.

¡     If you have selected correct drives, select SUBMIT and then press Enter.

Figure 15 Drive initiation risk warning screen

 

Configuring RAID arrays

1.     On the storage controller configuration screen as shown in Figure 16, select Logical Device Configuration, and press Enter.

Figure 16 Storage controller configuration screen

 

2.     On the screen as shown in Figure 17, select Create Array, and press Enter.

Figure 17 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 18, select the drives to be configured as a RAID array. ([Enabled] following a drive means that the drive has been selected.) Then, select PROCEED and press Enter.

A raw drive cannot be selected. To configure a RAID array for the drive, you must first initialize the drive. For more information about initializing drives, see "Initializing drives."

Figure 18 Selecting drives

 

4.     On the screen as shown in Figure 19, select Array type to set a RAID level, select PROCEED, and press Enter.

Figure 19 Selecting a RAID level

 

5.     On the screen as shown in Figure 20, set the Array Label, Stripe Size, Array Size, Array Size Selection, Read Cache, Write Cache, and Create RAID via parameters, select SUBMIT, and press Enter to create the array.

Table 4 describes the configuration parameters.

Figure 20 Setting RAID parameters

 

Table 4 Configuration parameters

Parameter

Description

Array Label

RAID array name. The default is DefaultValue0.

Stripe Size

Strip size, which determines the data block size of a stripe on each drive.

Array Size Selection

RAID array capacity.

Read Cache

Read cache policy status. Options are Enabled and Disabled.

Write Cache

Write cache policy status:

·     Enable AlwaysAlways enables the write cache. Without a supercapacitor installed, this status might cause data loss if power supply fails.

·     Enable With Backup UnitDisables the write cache when the supercapacitor is absent or not ready.

·     DisabledDisables the write cache.

Create RAID via

Operation after the RAID array is created. Options are as follows:

·     Quick Init—Performs initialization only when the corresponding stripe is accessed after the RAID array is created.

·     Skip Init—Establishes the RAID relationship immediately after the RAID array is created without clearing the data.

·     Build/Verify—Verifies the data for the drives after the RAID array is created to make the drives comply with the RAID level.

·     Clear—Clears the data of drives after the RAID array is created, which takes a long time.

 

 

NOTE:

If Build/Verify is selected, the read/write performance of a drive is low when the data of the drive is being verified. Do not perform any other tasks until the drive status becomes Optimal.

 

6.     On the storage controller configuration screen, select Logical Device Configuration > Manage Arrays, and press Enter, as shown in Figure 21.

Figure 21 Logical Device Configuration screen

 

7.     On the screen as shown in Figure 22, the created RAID array is displayed. Select the RAID array, and press Enter.

Figure 22 Manage Arrays screen

 

8.     On the RAID management screen that opens, select Array Properties, and press Enter to view detailed information about the RAID array (including the RAID array name, RAID level, and member drives), as shown in Figure 23.

Figure 23 RAID array information screen

 

Configuring hot spare drives

After configuring a RAID array, you can configure hot spare drives for the RAID array to improve the data security. You can configure global or dedicated hot spare drives as needed.

Configuring global hot spare drives

1.     On the storage controller configuration screen as shown in Figure 24, select Logical Device Configuration, and press Enter.

Figure 24 Storage controller configuration screen

 

2.     On the screen as shown in Figure 25, select Global Hotspares, and press Enter.

Figure 25 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 26, select Add Spares, and press Enter.

Figure 26 Global Hotspares configuration screen

 

 

NOTE:

To delete a host spare drive, select Delete Spares on the screen as shown in Figure 26.

 

4.     On the screen as shown in Figure 27, select the drives to be configured as global hot spare drives. ([Enabled] following a drive means that the drive has been selected.) Then, select ADD, and press Enter to configure the global hot spare drives.

Figure 27 Selecting drives

 

 

NOTE:

To configure a raw drive as a hot spare drive, you must first initialize the drive. For how to initialize drives, see "Initializing drives."

 

Configuring dedicated hot spare drives

1.     On the storage controller configuration screen, select Logical Device Configuration > Manage Arrays, and press Enter.

2.     On the screen as shown in Figure 28, select the RAID array for which you want to configure dedicated hot spare drives, and press Enter.

Figure 28 Selecting a RAID array

 

3.     On the screen as shown in Figure 29, select Failover Assignments, and press Enter.

Figure 29 Selecting Failover Assignments

 

4.     On the screen as shown in Figure 30, select Add Spares, and press Enter.

Figure 30 Failover Assignments

 

5.     On the screen as shown in Figure 31, select the drives to be configured as dedicated hot spare drives. ([Enabled] following a drive means that the drive has been selected.) Then, select ADD, and press Enter to configure the dedicated hot spare drives.

Figure 31 Selecting drives

 

Deleting RAID arrays

1.     On the storage controller configuration screen as shown in Figure 32, select Logical Device Configuration, and press Enter.

Figure 32 Storage controller configuration screen

 

2.     On the screen as shown in Figure 33, select Manage Arrays, and press Enter.

Figure 33 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 34, select the RAID array to be deleted, and press Enter.

Figure 34 Selecting the RAID array to be deleted

 

4.     On the screen as shown in Figure 35, select Delete Array, and press Enter.

Figure 35 Selecting Delete Array

 

5.     On the screen as shown in Figure 36, select PROCEED or SUBMIT, and press Enter to delete the selected RAID array.

Figure 36 Deleting a RAID array

 

Uninitializing drives

Perform this task to clear data, Adaptec metadata, and reserved space on drives, and remove the system partitions. After a drive in Ready state is uninitialized, it returns to the raw state.

To uninitialize drives:

1.     On the storage controller configuration screen as shown in Figure 37, select Logical Device Configuration, and press Enter.

Figure 37 Storage controller configuration screen

 

2.     On the screen as shown in Figure 38, select Uninitialize Drives, and press Enter.

Figure 38 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 39, select the drives to be uninitialized. ([Enabled] following a drive means the drive has been selected.) Then, select SUBMIT, and press Enter to uninitialize the drives.

Figure 39 Selecting drives

 

Locating drives

1.     On the storage controller configuration screen as shown in Figure 40, select Disk Utilities, and press Enter.

Figure 40 Storage controller configuration screen

 

2.     On the screen as shown in Figure 41, select the drive to be operated, and press Enter.

Figure 41 Selecting a drive

 

3.     On the screen as shown in Figure 42, select an operation (Identify Drive in this example), and press Enter.

Table 5 describes the operation options.

Figure 42 Drive information display/operation screen

 

Table 5 Operation options

Option

Description

Verify Disk Media

Verify the media of the drive.

Identify Drive

Locate the drive. With this operation performed for a drive, the Fault/UID LED on the drive backplane turns steady blue.

Write Cache

Set the write cache for the drive.

 

4.     On the screen as shown in Figure 43, select PROCEED, and press Enter.

Then, the Fault/UID LED on the drive turns steady blue.

Figure 43 Locating the drive

 

Erasing drives

WARNING

WARNING!

·     To avoid data loss, do not enter the operating system and read or write the drives during the drive erasing process.

·     To avoid drive failure, do not perform any other operations during the drive erasing process.

 

To erase drives:

1.     On the storage controller configuration screen as shown in Figure 44, select Logical Device Configuration, and press Enter.

Figure 44 Storage controller configuration screen

 

2.     On the screen as shown in Figure 45, select Secure Erase Drives, and press Enter.

Figure 45 Selecting Secure Erase Drives

 

3.     On the screen as shown in Figure 46, select the drives to be erased. ([Enabled] following a drive means that the drive has been selected.) Then, select SUBMIT, and press Enter.

Figure 46 Selecting the drives to be erased

 

4.     On the screen as shown in Figure 47, select PROCEED or SUBMIT, and press Enter to erase the drives.

Figure 47 Erasing drives

 

Restoring the default configuration for a storage controller

1.     On the storage controller configuration screen as shown in Figure 48, select Controller Settings, and press Enter.

Figure 48 Storage controller configuration screen

 

2.     On the screen as shown in Figure 49, select Controller Configuration, and press Enter.

Figure 49 Controller Settings screen

 

3.     On the screen as shown in Figure 50, you can view the basic configuration of the storage controller. Select RESET, and press Enter.

 

IMPORTANT

IMPORTANT:

The backplane mode sets the LED lighting policy. After the storage controller configuration is restored to the default, the LED lighting policy becomes IBPI, which causes the LED to operate abnormally. You must set the LED lighting policy to SGPIO.

 

Figure 50 Controller Configuration screen

 

4.     On the screen as shown in Figure 51, select PROCEED or SUBMIT, and press Enter to restore the storage controller configuration to the default.

Figure 51 Restoring the storage controller configuration to the default

 

Upgrading the storage controller firmware online

1.     On the storage controller configuration screen as shown in Figure 52, select Administration, and press Enter.

Figure 52 Storage controller configuration screen

 

2.     On the screen as shown in Figure 53, select FW update from Media, and press Enter.

Figure 53 Administration screen

 

3.     On the screen as shown in Figure 54, select the device where the update file resides (fs1 in this example), and press Enter.

Figure 54 Selecting the device where the update file resides

 

4.     On the screen as shown in Figure 55, select the .ufi file and press Enter.

Figure 55 Selecting the update file

 

5.     On the screen as shown in Figure 56, select Update Flash, and press Enter to start the update process. Wait until the update process is complete.

Figure 56 Selecting Update Flash

 

6.     After the update is complete, press F4. On the dialog box that opens, select Yes to reboot the device and make the update take effect.

Enabling RAID rebuilding

If hot spare drives are not configured, you can perform this task to enable RAID rebuilding manually. If hot spare drives are configured, the system performs RAID rebuilding as required after a drive replacement, which is not affected by the status of the RAID rebuilding feature.

To enable RAID rebuilding:

1.     On the storage controller configuration screen as shown in Figure 57, select Controller Settings, and press Enter.

Figure 57 Storage controller configuration screen

 

2.     On the screen as shown in Figure 58, select Controller Configuration, and press Enter.

Figure 58 Controller Settings screen

 

3.     On the screen as shown in Figure 59, set Automatic Failover to Enabled.

Figure 59 Controller Configuration screen

 

4.     Select SUBMIT and then press Enter.

Migrating RAID levels

You can perform RAID level migration for the RAID-P430-M1 and RAID-P430-M2 storage controllers only by using ARCCONF commands. For more information, see "xxx."

Expanding RAID capacity

You can perform RAID capacity expansion for the RAID-P430-M1 and RAID-P430-M2 storage controllers only by using ARCCONF commands. For more information, see "xxx" and "xxx."

Forcing logical drives to come online

If the number of offline drives exceeds the tolerance range of the logical drive fault-tolerant method, the management tool interface will display the logical disk state as Failed. In this case, you can use the Force Online function to force the logical drives to come online.

 

CAUTION

CAUTION:

The Force Online operation sets all available drives to the Optimal state without considering data consistency among member drives of a logical drive. Even if the Force Online operation is successful, if one or more drives contain outdated data, all data on this logical device may be changed or lost.

 

To force logical drives to come online:

1.     On the storage controller screen, select Logical Device Configuration and then press Enter.

Figure 60 Storage controller screen

 

2.     Select Manage Arrays and then press Enter.

Figure 61 Logical Device Configuration screen

 

3.     Select a RAID array in Failed state, and then press Enter.

Figure 62 Manage Arrays screen

 

4.     Select Force Online and then press Enter.

Figure 63 Force Online

 

Configuring RAID arrays in legacy mode

This section describes how to configure RAID arrays through a storage controller in legacy mode. For more information about how to enter the BIOS and set the boot mode to legacy, see the BIOS user guide for the server.

RAID array configuration tasks at a glance

To configure RAID arrays in legacy mode, perform the following tasks:

·     Accessing the storage controller configuration screen

·     Switching the storage controller operating mode

·     Scanning drives

·     Initializing drives

·     Configuring RAID arrays

·     (Optional.) Configuring boot options

·     (Optional.) Deleting RAID arrays

·     (Optional.) Uninitializing drives

·     (Optional.) Erasing drives

·     (Optional.) Locating drives

·     (Optional.) Modifying storage controller settings

Accessing the PMC RAID management screen

1.     During server POST, press Ctrl+A when the screen as shown in Figure 64 opens.

Figure 64 Pressing Ctrl+A as prompted during server POST

 

2.     The screen as shown in Figure 65 opens, which displays the storage controller version and status information.

Figure 65 Loading screen

 

3.     The PMC RAID management screen as shown in Figure 66 opens.

Table 6 describes the configuration options. For how to navigate screens and modify settings, see the operation instructions at the bottom.

Figure 66 PMC RAID management screen

 

Table 6 Configuration tasks

Option

Description

Logical Device Configuration

Select Logical Device Configuration to perform the following tasks:

·     Manage RAID arrays.

·     Create RAID arrays.

·     Initialize or uninitialize drives.

·     Erase drives.

·     Configure boot options.

Controller Settings

Select Controller Settings to perform the following tasks:

·     Modify the storage controller operating mode.

·     Restore the default configuration for a storage controller.

Disk Utilities

Select Disk Utilities to perform the following tasks:

·     Format drives.

·     Locate physical drives.

 

Switching the storage controller operating mode

1.     On the PMC RAID management screen as shown in Figure 67, select Controller Settings, and press Enter.

Figure 67 PMC RAID management screen

 

2.     On the screen as shown in Figure 68, select Controller Configuration, and press Enter.

Figure 68 Controller Settings screen

 

3.     On the screen as shown in Figure 69, select Controller Mode, and press Enter.

Figure 69 Controller Configuration screen

 

4.     On the screen as shown in Figure 70, select a storage controller operating mode (Table 7 describes the storage controller operating modes), and press Enter.

Figure 70 Selecting a storage controller operating mode

 

Table 7 Storage controller operating modes

Operating mode

Description

RAID: expose RAW

All RAID functions can be used. Raw physical drives are exposed to the system.

RAID: hide RAW

All RAID functions can be used. Raw physical drives are not exposed to the system.

HBA

RAID functions are disabled. Raw physical drives are exposed to the system. Before setting this mode, you must delete all RAID arrays and hot spare drives, and perform the Uninitializing drives operation for all drives.

Auto Volume

In this mode, raw physical drives with system partitions are exposed to the system, and physical drives without system partitions are configured as simple volumes. Before setting this mode, you must delete all RAID arrays and hot spare drives in the system.

Simple Volume

In this mode, only non-redundant RAID arrays with the simple volume level (each contains only one drive) can be created. RAID arrays with other RAID levels cannot be created. Before setting this mode, you must delete all RAID arrays and hot spare drives in the system.

 

5.     Reboot the operating system to make the storage controller operating mode configuration take effect.

Scanning drives

The storage controller might fail to timely recognize drives after the drives are hot swapped. To solve this problem, you can scan drives.

To scan drives:

1.     On the PMC RAID management screen as shown in Figure 71, select Logical Device Configuration, and press Enter.

Figure 71 PMC RAID management screen

 

2.     On the screen as shown in Figure 72, select Rescan Drives, and press Enter.

Figure 72 Logical Device Configuration screen

 

Initializing drives

Initializing a drive is to divide a small partition in the drive for saving the RAID information. A raw drive must be initialized before it is used for creating a RAID array or configured as a hot spare drive.

To initialize drives:

1.     On the PMC RAID management screen as shown in Figure 73, select Logical Device Configuration, and press Enter.

Figure 73 PMC RAID management screen

 

2.     On the screen as shown in Figure 74, select Initialize Drives, and press Enter.

Figure 74 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 75, navigate to the drive that you want to initialize, and press Insert to select the drive. Repeat this step to select more drives. Then, press Enter.

Figure 75 Selecting and initializing drives

 

Configuring RAID arrays

1.     On the PMC RAID management screen as shown in Figure 76, select Logical Device Configuration, and press Enter.

Figure 76 PMC RAID management screen

 

2.     On the screen as shown in Figure 77, select Create Array, and press Enter.

Figure 77 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 78, navigate to the drive to be configured for a RAID array, and press Insert to select the drive. Repeat this step to select more drives. Then, press Enter.

Figure 78 Selecting drives

 

4.     On the screen as shown in Figure 79, set the Array Type, Array Label, Array Size, Stripe Size, Read Caching, Write Caching, and Create RAID via parameters, select Done, and press Enter.

Table 8 describes the parameters.

Figure 79 Setting RAID parameters

 

Table 8 Configuration parameters

Parameter

Description

Array Type

Select a RAID level, which determines the performance, fault tolerance capability, and capacity of the logical drive.

Array Label

RAID array name, which must be manually entered.

Array Size

RAID array capacity.

Stripe Size

Strip size, which determines the data block size of a stripe on each drive.

Read Caching

Read cache.

Write Caching

Write cache.

Create RAID via

Select a method for initializing the RAID array.

 

5.     After the RAID array is created, select Manage Arrays, and press Enter on the screen as shown in Figure 80.

Figure 80 Selecting Manage Arrays

 

6.     On the screen as shown in Figure 81, select the RAID array that you want to view, and press Enter to view the RAID array details (including the RAID array name, RAID level, and member drives).

Figure 81 Viewing RAID array information

 

Configuring boot options

This section describes how to configure boot options. You can configure a logical drive or physical drive as the first boot option.

Configuring a logical drive as the first boot option

Only a logical drive in Optimal state can be configured as the first boot option.

To configure a logical drive as the first boot option:

1.     On the PMC RAID management screen as shown in Figure 82, select Logical Device Configuration, and press Enter.

Figure 82 PMC RAID management screen

 

2.     On the screen as shown in Figure 83, select Manage Arrays, and press Enter.

Figure 83 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 84, select a RAID array, and press Ctrl+B to configure it as the first boot option.

Figure 84 Selecting the RAID array to be configured as the first boot option

 

Configuring a physical drive as the first boot option

Only a raw physical drive can be configured as the first boot option. To configure a physical drive in any other state as the first boot option, you must first perform the Uninitializing drives operation for the drive.

In legacy mode, after you configure the storage controller to operate in HBA mode, you must configure a raw drive as the first boot option. Otherwise, the operating system cannot be installed or started.

To configure a physical drive as the first boot option:

1.     On the PMC RAID management screen, select Logical Device Configuration, and press Enter.

2.     On the screen as shown in Figure 85, select Select Boot Device, and press Enter.

Figure 85 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 86, navigate to the drive to be used as the boot device, press Insert to select the drive, and press Enter.

Figure 86 Selecting a drive

 

Deleting RAID arrays

1.     On the PMC RAID management screen as shown in Figure 87, select Logical Device Configuration, and press Enter.

Figure 87 PMC RAID management screen

 

2.     On the screen as shown in Figure 88, select Manage Arrays, and press Enter.

Figure 88 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 89, select the RAID array to be deleted, and press Delete to delete it.

Figure 89 Deleting a RAID array

 

Uninitializing drives

IMPORTANT

IMPORTANT:

When the storage controller operating mode is HBA, you cannot uninitialize drives. To uninitialize these drives, you must first set the storage controller operating mode to RAID: hide RAW, RAID: expose RAW, Auto Volume, or Simple Volume.

 

Perform this task to clear data, Adaptec metadata, and reserved space on drives, and remove the system partitions. After a drive in Ready state is uninitialized, it returns to the raw state.

To uninitialize drives:

1.     On the PMC RAID management screen, select Logical Device Configuration, and press Enter.

2.     On the screen as shown in Figure 90, select Uninitialize Drives, and press Enter.

Figure 90 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 91, navigate to the drive that you want to uninitialize, and press Insert to select the drive. Repeat this step to select more drives. Then, press Enter to uninitialize the selected drives.

Figure 91 Selecting and uninitializing drives

 

Erasing drives

CAUTION

CAUTION:

·     To avoid data loss, do not enter the operating system and read or write the drives during the drive erasing process.

·     To avoid drive failure, do not perform any other operating during the drive erasing process.

 

To erase drives:

1.     On the PMC RAID management screen as shown in Figure 92, select Logical Device Configuration, and press Enter.

Figure 92 PMC RAID management screen

 

2.     On the screen as shown in Figure 93, select Secure Erase Drives, and press Enter.

Figure 93 Logical Device Configuration screen

 

3.     On the screen as shown in Figure 94, navigate to the drive that you want to erase, and press Insert to select the drive. Repeat this step to select more drives. Then, press Enter.

Figure 94 Erasing drives

 

Locating drives

1.     On the PMC RAID management screen as shown in Figure 95, select Disk Utilities, and press Enter.

Figure 95 PMC RAID management screen

 

2.     On the screen as shown in Figure 96, you can view the drive information. Select the drive to be operated, and press Enter.

Figure 96 Disk Utilities screen

 

3.     On the screen as shown in Figure 97, select Identify Drive and press Enter. The Fault/UID LED on the drive turns steady blue.

Figure 97 Operating the drive

 

Modifying storage controller settings

Perform this task to view the storage controller configuration information, restore the default configuration for the storage controller, and modify the storage controller settings.

To modify storage controller settings:

1.     On the PMC RAID management screen as shown in Figure 98, select Controller Settings, and press Enter.

Figure 98 PMC RAID management screen

 

2.     On the screen as shown in Figure 99, select Controller Configuration, and press Enter.

Figure 99 Controller Settings screen

 

3.     On the screen as shown in Figure 100, you can view or modify the basic configuration information for the storage controller. Press F6 to restore the default configuration for the storage controller.

You can set the storage controller operating mode, backplane mode, whether to display physical drives during POST, and RAID rebuilding status.

 

 

NOTE:

Backplane Mode is used to set the LED lighting policy. After restoring the default configuration of the storage controller, the LED lighting policy changes to IBPI, which may cause the LED status display to not comply with the specification. You must set the LED lighting policy to SGPIO.

 

Figure 100 Controller Configuration screen

 

Forcing logical drives to come online

If the number of offline drives exceeds the tolerance range of the logical drive fault-tolerant method, the management tool interface will display the logical disk state as Failed. In this case, you can use the Force Online function to force the logical drives to come online.

 

CAUTION

CAUTION:

The Force Online operation sets all available drives to the Optimal state without considering data consistency among member drives of a logical drive. Even if the Force Online operation is successful, if one or more drives contain outdated data, all data on this logical device may be changed or lost.

 

To force logical drives to come online:

1.     On the storage controller screen, select Logical Device Configuration and then press Enter.

Figure 101 Storage controller screen

 

2.     Select Manage Arrays and then press Enter.

Figure 102 Logical Device Configuration screen

 

3.     Select a RAID array in Failed state, press Enter, and then press Ctrl+F.

Figure 103 Manage Arrays screen

 

Downloading and installing ARCCONF

This section introduces the download and installation steps of the OS command line tool. You can use the OS command line tool to manage storage controllers during normal server operation without restarting the server.

Downloading ARCCONF

1.     Access https://www.h3c.com/cn/BizPortal/DownLoadAccessory/DownLoadAccessoryFilt.aspx.

2.     Download the installation package and release notes for the corresponding storage controller firmware as instructed.

3.     Decompress the installation package to obtain the ARCCONF tool package for different operating systems.

Installing ARCCONF

See the release notes to install ARCCONF for the corresponding operating system.

Commonly-used commands in ARCCONF

This section describes the usage and examples of commonly used commands in ARCCONF. You can use ARCCONF commands to manage storage controllers during normal server operation without restarting the server.

Upgrading the storage controller firmware

Perform this task to upgrade the storage controller firmware.

Syntax

arcconf romupdate controller_id fwfile

Parameters

controller_id: Specifies the ID of the storage controller.

fwfile: Specifies the name of the firmware file.

Examples

# Upgrade the storage controller firmware.

[root@localhost 007]# arcconf romupdate 1 REDWOODZ_2G01.ufi

Controllers found: 1

 

 

Are you sure you want to continue?

Press y, then ENTER to continue or press ENTER to abort: y

 

Updating controller 1 firmware...

Succeeded

You must restart the system for firmware updates to take effect.

 

 

Command completed successfully.

Viewing basic information about a storage controller

Perform this task to view basic information about a storage controller.

Syntax

arcconf list controller_id

Parameters

controller_id: Specifies the ID of the storage controller.

Examples

# View attributes of storage controller 1.

[root@localhost ~]# arcconf list 1

Controllers found: 1

----------------------------------------------------------------------

Controller information

----------------------------------------------------------------------

   Controller ID             : Status, Slot, Mode, Name, SerialNumber, WWN

----------------------------------------------------------------------

   Controller 1:             : Optimal, Slot Unknown, RAID (Expose RAW), PM8060-RAID , FADC8000, 5600B036FADC8000

 

 

----------------------------------------------------------------------

Logical device information

----------------------------------------------------------------------

   Logical ID                : Status (RAID, Interface, Size MB) Name

----------------------------------------------------------------------

   No logical devices configured

 

----------------------------------------------------------------------

maxCache 3.0 information

----------------------------------------------------------------------

   maxCache Logical ID       : Status (RAID, Interface, Size MB) Name

----------------------------------------------------------------------

No maxCache 3.0 found

 

----------------------------------------------------------------------

Physical Device information

----------------------------------------------------------------------

   Physical ID               : State (Interface, BlockSize, SizeMB, Vendor, Model, Type) WWN, [Location]

----------------------------------------------------------------------

   Physical 0,33             : Raw (Pass Through) (SATA, 512 Bytes, 5723166MB, ATA, ST6000NM0115-1YZ11 , Hard Drive) 5000C50ctor 0, Connector 1)]

   Physical 0,34             : Raw (Pass Through) (SATA, 512 Bytes, 7630885MB, ATA, ST8000NM000A-2KE10 , Hard Drive) 5000C50ctor 0, Connector 1)]

   Physical 0,35             : Raw (Pass Through) (SATA, 512 Bytes, 15259648MB, ATA, ST16000NM000G-2KH13, Hard Drive) 5000C5ector 0, Connector 1)]

   Physical 0,36             : Raw (Pass Through) (SATA, 512 Bytes, 15259648MB, ATA, ST16000NM000G-2KH13, Hard Drive) 5000C5ector 0, Connector 1)]

   Physical 0,37             : Raw (Pass Through) (SATA, 512 Bytes, 15259648MB, ATA, ST16000NM000G-2KH13, Hard Drive) 5000C5ector 0, Connector 1)]

   Physical 2,0              : Ready (SES2, Not Applicable, Not Applicable, LSI, Cub, Enclosure Services Device) 500605B0000

   Physical 2,1              : Ready (SES2, Not Applicable, Not Applicable, LSI, Cub, Enclosure Services Device) 500605B0000

 

 

Command completed successfully.

Viewing physical drive, array, LD, and storage controller information

Perform this task to view basic information about a storage controller.

Syntax

Table 9 View storage controller information

Command

Function

arcconf getconfig controller_id AD

View storage controller information.

arcconf getconfig controller_id LD

View information about all the LD for a storage controller.

arcconf getconfig controller_id LD LD_id

View information about the specified LD.

arcconf getconfig controller_id PD

View information about all physical drives for a storage controller.

arcconf getconfig controller_id PD channel_id device_id

View information about the specified physical drive.

arcconf getconfig controller_id AR

View information about all arrays for a storage controller.

arcconf getconfig controller_id AR AR_id

View information about the specified array.

 

Parameters

controller_id: Specifies the ID of the storage controller.

LD_id: Specifies the ID of a logical drive.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

AR_id: Specifies the ID of an array.

Examples

# View information about all arrays.

[root@localhost ~]# ./arcconf getconfig 1 ar

Controllers found: 1

----------------------------------------------------------------------

Array Information

----------------------------------------------------------------------

Array Number 0

   Name                                     : A

   Status                                   : Ok

   Interface                                : SATA SSD

   Total Size                               : 305152 MB

   Unused Size                              : 204800 MB

   Block Size                               : 512 Bytes

   Array Utilization                        : 32.77% Used, 67.23% Unused

   Type                                     : Data

   Transformation Status                    : Not Applicable

   Spare Rebuild Mode                       : Dedicated

   SSD I/O Bypass                           : Disabled

   --------------------------------------------------------

   Array Logical Device Information

   --------------------------------------------------------

   Logical 0                                : Optimal (1, Data, 49999 MB) LogicalDrv 0

   --------------------------------------------------------

   Array Physical Device Information

   --------------------------------------------------------

   Device 0                                 : Present (915715MB, SATA, SSD, Channel:0, Device:0)         18031A983BCA

   Device 1                                 : Present (152627MB, SATA, SSD, Channel:0, Device:1) CVPR1461036N160DGN

 

   --------------------------------------------------------

   Array Hotspare Information

   --------------------------------------------------------

   Device 3                                 : Dedicated Hot-Spare (457862MB, SATA, SSD, Channel:0, Device:3)             2029E247 +

 

 

 

Command completed successfully.

[root@localhost ~]#

# View basic information about all LDs.

[root@localhost home]# arcconf getconfig 1 ld

Controllers found: 1

----------------------------------------------------------------------

Logical device information

----------------------------------------------------------------------

Logical Device number 0

   Logical Device name                        : LogicalDrv 0

   Disk Name                                  : /dev/sdg

   Block Size of member drives                : 512 Bytes

   Array                                      : 0

   RAID level                                 : 1

   Status of Logical Device                   : Optimal

   Size                                       : 457830 MB

   Stripe-unit size                           : 256 KB

   Full Stripe Size                           : 256 KB

   Interface Type                             : SATA SSD

   Device Type                                : Data

   Boot Type                                  : None

   Heads                                      : 255

   Sectors Per Track                          : 32

   Cylinders                                  : 65535

   Caching                                    : Enabled

   Mount Points                               : Not Mounted

   LD Acceleration Method                     : Controller Cache

   Volume Unique Identifier                   : 600508B1001C3F40059B7A4BF459DD3C

   --------------------------------------------------------

   Array Physical Device Information

   --------------------------------------------------------

   Device 8                                   : Present (457862MB, SATA, SSD, Connector:CN0, Enclosure:1, Slot:0) BTYF8316086G480BGN

   Device 9                                   : Present (457862MB, SATA, SSD, Connector:CN0, Enclosure:1, Slot:1) BTYF95230EMQ480BGN

 

 

 

 

Command completed successfully.

# View basic information about all PDs.

[root@localhost home]# arcconf getconfig 1 pd

Controllers found: 1

----------------------------------------------------------------------

Physical Device information

----------------------------------------------------------------------

      Device #0

         Device is a Hard drive

         State                                : Raw (Pass Through)

         Block Size                           : 512 Bytes

         Supported                            : Yes

         Programmed Max Speed                 : SAS 12.0 Gb/s

         Transfer Speed                       : SAS 12.0 Gb/s

         Reported Channel,Device(T:L)         : 0,0(0:0)

         Reported Location                    : Enclosure 0, Slot 0(Connector 0)

         Reported ESD(T:L)                    : 2,0(0:0)

         Vendor                               : SEAGATE

         Model                                : ST300MP0006

         Firmware                             : N002

         Serial number                        : WAE02RZM0000E74049PF

         World-wide name                      : 5000C5009F4A36B0

         Reserved Size                        : 0 KB

         Total Size                           : 286102 MB

         Write Cache                          : Disabled (write-through)

         FRU                                  : None

         S.M.A.R.T.                           : No

         S.M.A.R.T. warnings                  : 0

         Power State                          : Full rpm

         Supported Power States               : Full rpm,Powered off

         SSD                                  : No

         Temperature                          : 37 C/ 98 F

      ----------------------------------------------------------------

      Device Phy Information                 

      ----------------------------------------------------------------

         Phy #0

            PHY Identifier                    : 0

            SAS Address                       : 5000C5009F4A36B1

            Attached PHY Identifier           : 3

            Attached SAS Address              : 588DF9E365D39000

         Phy #1

            PHY Identifier                    : 1

            SAS Address                       : 5000C5009F4A36B2

      ----------------------------------------------------------------

      Runtime Error Counters                 

      ----------------------------------------------------------------

         Hardware Error Count                 : 0

         Medium Error Count                   : 0

         Parity Error Count                   : 0

         Link Failure Count                   : 0

         Aborted Command Count                : 0

         SMART Warning Count                  : 0

 

      Device #1

         Device is a Hard drive

         State                                : Raw (Pass Through)

         Block Size                           : 512 Bytes

         Supported                            : Yes

         Programmed Max Speed                 : SAS 12.0 Gb/s

         Transfer Speed                       : SAS 12.0 Gb/s

         Reported Channel,Device(T:L)         : 0,1(1:0)

         Reported Location                    : Enclosure 0, Slot 1(Connector 0)

         Reported ESD(T:L)                    : 2,0(0:0)

         Vendor                               : HGST

         Model                                : HUC101890CS4200

         Firmware                             : AD02

         Serial number                        : 04GAEYHA

         World-wide name                      : 5000CCA02E130057

         Reserved Size                        : 0 KB

         Total Size                           : 858483 MB

         Write Cache                          : Disabled (write-through)

         FRU                                  : None

         S.M.A.R.T.                           : No

         S.M.A.R.T. warnings                  : 0

         Power State                          : Full rpm

         Supported Power States               : Full rpm,Powered off

         SSD                                  : No

         Temperature                          : 39 C/ 102 F

      ----------------------------------------------------------------

      Device Phy Information                 

      ----------------------------------------------------------------

         Phy #0

            PHY Identifier                    : 0

            SAS Address                       : 5000CCA02E130055

            Attached PHY Identifier           : 2

            Attached SAS Address              : 588DF9E365D39000

         Phy #1

            PHY Identifier                    : 1

            SAS Address                       : 5000CCA02E130056

      ----------------------------------------------------------------

      Runtime Error Counters                 

      ----------------------------------------------------------------

         Hardware Error Count                 : 0

         Medium Error Count                   : 0

         Parity Error Count                   : 0

         Link Failure Count                   : 0

         Aborted Command Count                : 0

         SMART Warning Count                  : 0

 

      Device #2

         Device is a Hard drive

         State                                : Raw (Pass Through)

         Block Size                           : 512 Bytes

         Supported                            : Yes

         Programmed Max Speed                 : SAS 12.0 Gb/s

         Transfer Speed                       : SAS 12.0 Gb/s

         Reported Channel,Device(T:L)         : 0,2(2:0)

         Reported Location                    : Enclosure 0, Slot 2(Connector 0)

         Reported ESD(T:L)                    : 2,0(0:0)

         Vendor                               : SEAGATE

         Model                                : ST600MM0208

         Firmware                             : N001

         Serial number                        : W0M0C0470000K743K271

         World-wide name                      : 5000C5009FC2A428

         Reserved Size                        : 0 KB

         Total Size                           : 572325 MB

         Write Cache                          : Enabled (write-back)

         FRU                                  : None

         S.M.A.R.T.                           : No

         S.M.A.R.T. warnings                  : 0

         Power State                          : Full rpm

         Supported Power States               : Full rpm,Powered off

         SSD                                  : No

         Temperature                          : 34 C/ 93 F

      ----------------------------------------------------------------

      Device Phy Information                 

      ----------------------------------------------------------------

         Phy #0

            PHY Identifier                    : 0

            SAS Address                       : 5000C5009FC2A429

            Attached PHY Identifier           : 0

            Attached SAS Address              : 588DF9E365D39000

         Phy #1

            PHY Identifier                    : 1

            SAS Address                       : 5000C5009FC2A42A

      ----------------------------------------------------------------

      Runtime Error Counters                 

      ----------------------------------------------------------------

         Hardware Error Count                 : 0

         Medium Error Count                   : 0

         Parity Error Count                   : 0

         Link Failure Count                   : 0

         Aborted Command Count                : 0

         SMART Warning Count                  : 0

 

      Device #3

         Device is a Hard drive

         State                                : Raw (Pass Through)

         Block Size                           : 512 Bytes

         Supported                            : Yes

         Programmed Max Speed                 : SAS 12.0 Gb/s

         Transfer Speed                       : SAS 12.0 Gb/s

         Reported Channel,Device(T:L)         : 0,3(3:0)

         Reported Location                    : Enclosure 0, Slot 3(Connector 0)

         Reported ESD(T:L)                    : 2,0(0:0)

         Vendor                               : SEAGATE

         Model                                : ST300MP0006

         Firmware                             : N002

         Serial number                        : WAE00HDS0000E7289DJX

         World-wide name                      : 5000C5009E900F20

         Reserved Size                        : 0 KB

         Total Size                           : 286102 MB

         Write Cache                          : Disabled (write-through)

         FRU                                  : None

         S.M.A.R.T.                           : No

         S.M.A.R.T. warnings                  : 0

         Power State                          : Full rpm

         Supported Power States               : Full rpm,Powered off

         SSD                                  : No

         Temperature                          : 36 C/ 96 F

      ----------------------------------------------------------------

      Device Phy Information                 

      ----------------------------------------------------------------

         Phy #0

            PHY Identifier                    : 0

            SAS Address                       : 5000C5009E900F21

            Attached PHY Identifier           : 1

            Attached SAS Address              : 588DF9E365D39000

         Phy #1

            PHY Identifier                    : 1

            SAS Address                       : 5000C5009E900F22

      ----------------------------------------------------------------

      Runtime Error Counters                 

      ----------------------------------------------------------------

         Hardware Error Count                 : 0

         Medium Error Count                   : 0

         Parity Error Count                   : 0

         Link Failure Count                   : 0

         Aborted Command Count                : 0

         SMART Warning Count                  : 0

 

      Device #4

         Device is a Hard drive

         State                                : Raw (Pass Through)

         Block Size                           : 512 Bytes

         Supported                            : Yes

         Programmed Max Speed                 : SAS 12.0 Gb/s

         Transfer Speed                       : SAS 12.0 Gb/s

         Reported Channel,Device(T:L)         : 0,4(4:0)

         Reported Location                    : Enclosure 0, Slot 4(Connector 1)

         Reported ESD(T:L)                    : 2,0(0:0)

         Vendor                               : HGST

         Model                                : HUC101812CS4200

         Firmware                             : AD02

         Serial number                        : 06HXELAZ

         World-wide name                      : 5000CCA02D6C13AB

         Reserved Size                        : 0 KB

         Total Size                           : 1144641 MB

         Write Cache                          : Disabled (write-through)

         FRU                                  : None

         S.M.A.R.T.                           : No

         S.M.A.R.T. warnings                  : 0

         Power State                          : Full rpm

         Supported Power States               : Full rpm,Powered off

         SSD                                  : No

         Temperature                          : 37 C/ 98 F

      ----------------------------------------------------------------

      Device Phy Information                 

      ----------------------------------------------------------------

         Phy #0

            PHY Identifier                    : 0

            SAS Address                       : 5000CCA02D6C13A9

            Attached PHY Identifier           : 5

            Attached SAS Address              : 588DF9E365D39000

         Phy #1

            PHY Identifier                    : 1

            SAS Address                       : 5000CCA02D6C13AA

      ----------------------------------------------------------------

      Runtime Error Counters                 

      ----------------------------------------------------------------

         Hardware Error Count                 : 0

         Medium Error Count                   : 0

         Parity Error Count                   : 0

         Link Failure Count                   : 0

         Aborted Command Count                : 0

         SMART Warning Count                  : 0

 

      Device #5

         Device is an Enclosure Services Device

         Reported Channel,Device(T:L)         : 2,0(0:0)

         Enclosure ID                         : 0

         Type                                 : SES2

         Vendor                               : ADAPTEC

         Model                                : Virtual SGPIO

         Firmware                             :    1

         Status of Enclosure Services Device

            Speaker status                    : Not Available

 

 

Command completed successfully.              : Not Available

# View basic information about all ADs.

[root@localhost home]# arcconf getconfig 1 ad

Controllers found: 1

----------------------------------------------------------------------

Controller information

----------------------------------------------------------------------

   Controller Status                          : Optimal

   Controller Mode                            : RAID (Expose RAW)

   Channel description                        : SAS/SATA

   Controller Model                           : PM8060-RAID

   Controller Serial Number                   : 65D39000

   Controller World Wide Name                 : 588DF9E365D39000

   Controller Alarm                           : Enabled

   Temperature                                : 37 C/ 98 F (Normal)

   Installed memory                           : 2048 MB

   Host bus type                              : PCIe

   Host bus speed                             : 8000 MHz

   Host bus link width                        : 8 bit(s)/link(s)

   Global task priority                       : High

   Performance Mode                           : Default/Dynamic

   PCI Device ID                              : 653

   Stayawake period                           : Disabled

   Spinup limit internal drives               : 0

   Spinup limit external drives               : 0

   Defunct disk drive count                   : 0

   NCQ status                                 : Enabled

   Statistics data collection mode            : Disabled

   Monitor Log Severity Level                 : Informational

   Global Max SAS Phy Link Rate               : 12 Gbps

   Verify Write Setting                       : Not Applicable

   Save Custom Defaults Setting               : Unknown

   Smart Poll                                 : Enabled

   Error Tunable Profile                      : Normal

   Metadead Supported                         : Supported

   Metadead                                   : False

   --------------------------------------------------------

   Cache Properties

   --------------------------------------------------------

   Global Physical Device Write Cache Policy  : Enabled

   --------------------------------------------------------

   RAID Properties

   --------------------------------------------------------

   Logical devices/Failed/Degraded            : 0/0/0

   Copyback                                   : Enabled

   Automatic Failover                         : Enabled

   Background consistency check               : Disabled

   Background consistency check period        : 0

   --------------------------------------------------------

   Controller BIOS Setting Information

   --------------------------------------------------------

   Runtime BIOS                               : Enabled

   Array BBS Support                          : Disabled

   Physical Drives Displayed during POST      : Enabled

   Backplane Mode                             : SGPIO

   BIOS Halt on Missing Drive Count           : 255

   --------------------------------------------------------

   Controller Version Information

   --------------------------------------------------------

   BIOS                                       : 7.17-0 (33512)

   Firmware                                   : 7.17-0 (33512)

   Driver                                     : 1.2-1 (50877)

   Boot Flash                                 : 7.17-0 (33512)

   CPLD (Load version/ Flash version)         : 8/ 8

   SEEPROM (Load version/ Flash version)      : 1/ 1

   FCT Custom Init String Version             : 0x3

 

   --------------------------------------------------------

   Controller Cache Backup Unit Information

   --------------------------------------------------------

 

    Overall Backup Unit Status                : Ready

 

         Backup Unit Type                     : AFM-700/700LP

         Non-Volatile Storage Status          : Ready

         Supercap Status                      : Ready

 

         -------------------------------------

         Supercap Information                

         -------------------------------------

         Current Temperature                  : 25 deg C

         Threshold Temperature                : 55 deg C

         Life-time Temperature Recorded      

         (Min/Max)                            : -59 deg C/ 55 deg C

 

         Voltage(Present/Max)                 : 5370 mV/ 5302 mV

         Life-time Max Voltage Recorded       : 5412 mV

 

         Current Drawn(Present/Max)           : 0 mA/ 560 mA

         Health                               : 100 percent

         Charge Level                         : 100 percent

         Serial Number                        : 0123456789AB

 

         Learn Status                         : Active, Scheduled

 

         Present Capacitance                  : 300 farads

   --------------------------------------------------------

   Connector information

                    

   --------------------------------------------------------

   Connector #0                              

      Connector Name                          : CN0

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 0

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 3

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 1

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 2

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #2                                 

         Channel ID                           : 0

         Device ID                            : 2

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 0

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 3

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 1

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

 

   Connector #1                              

      Connector Name                          : CN1

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 4

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 5

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

            Attached PHY Identifier           : 0

            Attached SAS Address              : 5000CCA02D6C13A9

            Negotiated Logical Link Rate      : PHY enabled - 12 Gbps

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 5

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 6

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #2                                

         Channel ID                           : 0

         Device ID                            : 6

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 4

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 7

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 7

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

 

   Connector #2                              

      Connector Name                          : CN2

 

      ----------------------------------------

   Lane Information                           

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 8

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 10

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #0       

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 9

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 11

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #1       

 

      Lane #2                                

         Channel ID                           : 0

         Device ID                            : 10

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 9

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #2       

 

      Lane #3                                 

         Channel ID                           : 0

         Device ID                            : 11

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 8

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #3       

 

 

   Connector #3                              

      Connector Name                          : CN3

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 12

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 13

         -------------------------------------

         Lane SAS Phy Information             

         -------------------------------------

            No SAS Phy information available for lane #0       

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 13

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 12

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #1       

 

      Lane #2                                

         Channel ID                           : 0

         Device ID                            : 14

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 14

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #2       

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 15

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 15

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #3       

 

Command completed successfully.

Setting the drive UID LED

Perform this task to turn on or turn off the UID LEDs for physical drives, logical drives, or all the drives.

Syntax

Table 10 UID management-related commands

Command

Function

arcconf identify controller_id device channel_id device_id time time

Turn on the UID LED for the specified drive for a specific length of time.

arcconf identify controller_id device channel_id device_id

Turn on the UID LED for the specified drive. You can press any key to turn off the LED.

arcconf identify controller_id all time time

Turn on the UID LEDs for all physical drives for a specific length of time.

arcconf identify controller_id all stop

Turn off the UID LEDs for all physical drives.

arcconf identify controller_id logicaldrive LD_id time time

Turn on the UID LED for the specified LD for a specific length of time.

arcconf identify controller_id logicaldrive LD_id

Turn on the UID LED for the specified LD. You can press any key to turn off the LED.

arcconf identify controller_id array array_id

time time

Turn on the UID LED for the specified array for a specific length of time.

arcconf identify controller_id array array_id

Turn on the UID LED for the specified array. You can press any key to turn off the LED.

 

Parameters

controller_id: Specifies the ID of the storage controller.

LD_id: Specifies the ID of a logical drive.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

time: Specifies the time during which the LED is on, in seconds.

array_id: Specifies the ID of an array.

Examples

# Turn on the UID LED for the drive with device ID 8.

[root@localhost home]# arcconf identify 1 device 0 8

Controllers found: 1

Only devices managed by an enclosure processor may be identified

The specified device(s) is/are blinking.

Press any key to stop the blinking.

# Turn on the UID LEDs for all drives for 60 seconds.

[root@localhost home]# arcconf identify 1 all time 60

Controllers found: 1

Only devices managed by an enclosure processor may be identified

 

Command completed successfully.

# Turn off the UID LEDs for all drives.

[root@localhost home]# arcconf identify 1 all stop

Controllers found: 1

 

Command completed successfully.

# Turn on the UID LED for logical drive 0.

[root@localhost home]# arcconf identify 1 logicaldrive 0

Controllers found: 1

Only devices managed by an enclosure processor may be identified

The specified device(s) is/are blinking.

Press any key to stop the blinking.

Setting the operating mode of a storage controller

Perform this task to set the operating mode of a storage controller.

Syntax

arcconf setcontrollermode controller_id mode

Parameters

controller_id: Specifies the ID of the storage controller.

mode: Specifies the operating mode of a storage controller. Options include:

·     0: RAID, EXPOSE RAW

·     1: AUTO VOLUME MODE

·     2: HBA MODE

·     3: RAID, HIDE RAW

·     4: SIMPLE VOLUME MODE

Examples

# Set the storage controller mode to RAID:HIDE EXPOSE RAW.

[root@localhost home]# arcconf setcontrollermode 1 0

Controllers found: 1

Command completed successfully.

# View the storage controller mode.

[root@localhost home]# arcconf getconfig 1 ad

Controllers found: 1

----------------------------------------------------------------------

Controller information

----------------------------------------------------------------------

   Controller Status                          : Optimal

   Controller Mode                            : RAID (Expose RAW)

   Channel description                        : SAS/SATA

   Controller Model                           : PM8060-RAID

   Controller Serial Number                   : 65D39000

   Controller World Wide Name                 : 588DF9E365D39000

   Controller Alarm                           : Enabled

   Temperature                                : 37 C/ 98 F (Normal)

   Installed memory                           : 2048 MB

   Host bus type                              : PCIe

   Host bus speed                             : 8000 MHz

   Host bus link width                        : 8 bit(s)/link(s)

   Global task priority                       : High

   Performance Mode                           : Default/Dynamic

   PCI Device ID                              : 653

   Stayawake period                           : Disabled

   Spinup limit internal drives               : 0

   Spinup limit external drives               : 0

   Defunct disk drive count                   : 0

   NCQ status                                 : Enabled

   Statistics data collection mode            : Disabled

   Monitor Log Severity Level                 : Informational

   Global Max SAS Phy Link Rate               : 12 Gbps

   Verify Write Setting                       : Not Applicable

   Save Custom Defaults Setting               : Unknown

   Smart Poll                                 : Enabled

   Error Tunable Profile                      : Normal

   Metadead Supported                         : Supported

   Metadead                                   : False

   --------------------------------------------------------

   Cache Properties

   --------------------------------------------------------

   Global Physical Device Write Cache Policy  : Enabled

   --------------------------------------------------------

   RAID Properties

   --------------------------------------------------------

   Logical devices/Failed/Degraded            : 0/0/0

   Copyback                                   : Enabled

   Automatic Failover                         : Enabled

   Background consistency check               : Disabled

   Background consistency check period        : 0

   --------------------------------------------------------

   Controller BIOS Setting Information

   --------------------------------------------------------

   Runtime BIOS                               : Enabled

   Array BBS Support                          : Disabled

   Physical Drives Displayed during POST      : Enabled

   Backplane Mode                             : SGPIO

   BIOS Halt on Missing Drive Count           : 255

   --------------------------------------------------------

   Controller Version Information

   --------------------------------------------------------

   BIOS                                       : 7.17-0 (33512)

   Firmware                                   : 7.17-0 (33512)

   Driver                                     : 1.2-1 (50877)

   Boot Flash                                 : 7.17-0 (33512)

   CPLD (Load version/ Flash version)         : 8/ 8

   SEEPROM (Load version/ Flash version)      : 1/ 1

   FCT Custom Init String Version             : 0x3

 

   --------------------------------------------------------

   Controller Cache Backup Unit Information

   --------------------------------------------------------

 

    Overall Backup Unit Status                : Ready

 

         Backup Unit Type                     : AFM-700/700LP

         Non-Volatile Storage Status          : Ready

         Supercap Status                      : Ready

 

         -------------------------------------

         Supercap Information                

         -------------------------------------

         Current Temperature                  : 25 deg C

         Threshold Temperature                : 55 deg C

         Life-time Temperature Recorded      

         (Min/Max)                            : -59 deg C/ 55 deg C

 

         Voltage(Present/Max)                 : 5370 mV/ 5302 mV

         Life-time Max Voltage Recorded       : 5412 mV

 

         Current Drawn(Present/Max)           : 0 mA/ 560 mA

         Health                               : 100 percent

         Charge Level                         : 100 percent

         Serial Number                        : 0123456789AB

 

         Learn Status                         : Active, Scheduled

 

         Present Capacitance                  : 300 farads

   --------------------------------------------------------

   Connector information

                     

   --------------------------------------------------------

   Connector #0                              

      Connector Name                          : CN0

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 0

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 3

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 1

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 2

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #2                                 

         Channel ID                           : 0

         Device ID                            : 2

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 0

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 3

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 1

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

 

   Connector #1                              

      Connector Name                          : CN1

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 4

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 5

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

            Attached PHY Identifier           : 0

            Attached SAS Address              : 5000CCA02D6C13A9

            Negotiated Logical Link Rate      : PHY enabled - 12 Gbps

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 5

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 6

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #2                                

         Channel ID                           : 0

         Device ID                            : 6

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 4

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 7

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 7

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            SAS Address                       : 588DF9E365D39000

 

 

   Connector #2                              

      Connector Name                          : CN2

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 8

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 10

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #0       

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 9

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 11

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #1       

 

      Lane #2                                

         Channel ID                           : 0

         Device ID                            : 10

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 9

         -------------------------------------

         Lane SAS Phy Information             

         -------------------------------------

            No SAS Phy information available for lane #2       

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 11

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 8

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #3       

 

 

   Connector #3                              

      Connector Name                          : CN3

 

      ----------------------------------------

   Lane Information                          

      ----------------------------------------

      Lane #0                                

         Channel ID                           : 0

         Device ID                            : 12

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 13

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #0       

 

      Lane #1                                

         Channel ID                           : 0

         Device ID                            : 13

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 12

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #1       

 

      Lane #2                                

         Channel ID                           : 0

         Device ID                            : 14

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 14

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #2       

 

      Lane #3                                

         Channel ID                           : 0

         Device ID                            : 15

         SAS Address                          : 588DF9E365D39000

         PHY Identifier                       : 15

         -------------------------------------

         Lane SAS Phy Information            

         -------------------------------------

            No SAS Phy information available for lane #3       

 

 

 

 

Command completed successfully.

Creating and deleting RAID arrays

Perform this task to create and delete RAID arrays.

Syntax

arcconf create controller_id logicaldrive option size level channel_id device_id channel_id device_id……

arcconf delete controller_id logicaldrive ld_id noprompt

Parameters

controller_id: Specifies the ID of the storage controller.

option: Specifies the LD attributes. Attributes include:

·     Stripesize: Strip size of the LD.

·     Legs: NPG of the LD. This attribute is available only for RAID 50 and RAID 60.

·     Name: Name of the LD.

·     Method: Initialization method of the LD. Options include build and default.

size: Capacity of the LD. The unit is MB. Enter only the number here. For example, if you set the value to 1024, it indicates that the driver capacity is 1024 MB. If you set the value to MAX, it indicates that all the capacity of the physical drive is used to create the logical drive.

level: Level of the LD.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

Examples

# Create RAID 50.

[root@localhost home]# arcconf create 1 logicaldrive stripesize 512 legs 2 name VR1 method default max 50 0 8 0 9 0 10 0 11 0 12 0 13

Controllers found: 1

 

Do you want to add a logical device to the configuration?

Press y, then ENTER to continue or press ENTER to abort: y

 

Creating logical device: VR1

 

Command completed successfully.

# Delete the logical drive with ID 0.

[root@localhost home]# arcconf delete 1 logicaldrive 0 noprompt

Controllers found: 1

 

WARNING: Deleting this logical device will automatically delete array 0 because it is the only logical device present on that array.

All data in logical device 0 will be lost.

Deleting: logical device 0 ("LogicalDrv 0")

 

Command completed successfully.

Scaling up a logical drive

Perform this task to scale up a logical drive when physical drives have capacity not used by logical drives.

Syntax

arcconf modify controller_id from LD_id to LD_size LD_level channel_id device_id channel_id device_id

Parameters

controller_id: Specifies the ID of the storage controller.

LD_id: Specifies the ID of a logical drive.

LD_size: Specifies the new LD capacity, in MB.

LD_level: Specifies the RAID level.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

Usage guidelines

·     To ensure a successful scale-up, make sure you have obtained the correct RAID level, channel ID, and device ID of member drives.

·     Make sure the added capacity does not exceed the remaining capacity of the array in which the logical drive resides.

Examples

# Scale up the LD capacity to 204800 MB.

[root@localhost ~]# arcconf modify 1 from 0 to  204800 1 0 0 0 1
Controllers found: 1
Reconfiguration of a logical device is a long process.  Are you sure you want to continue?
Press y, then ENTER to continue or press ENTER to abort: y
 
Reconfiguring logical device: LogicalDrv 0
 
Command completed successfully.

Adding new drives to a RAID array

Perform this task to add new drives to an existing RAID array.

Syntax

arcconf modify controller_id array array_id expand channel_id device_id channel_id device_id......

Parameters

controller_id: Specifies the ID of the storage controller.

array_id: Specifies the ID of an array.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

Description

After adding a drive, see "Scaling up a logical drive" to scale up logical drives.

Examples

# Add new drives to the array.

[root@localhost ~]# arcconf modify 1 array 0 expand 0 10
Controllers found: 1
This will modify the array 0.
 
Are you sure you want to continue?
Press y, then ENTER to continue or press ENTER to abort: y
 
Modifying array: 0
 
Command completed successfully.

Migrating the RAID level

Perform this task to migrate the RAID level.

Syntax

arcconf modify controller_id from LD_id to LD_size LD_level channel_id device_id channel_id device_id......

Parameters

controller_id: Specifies the ID of the storage controller.

LD_id: Specifies the ID of a logical drive.

LD_size: Specifies the capacity of the LD before migration.

LD_level: Specifies the LD level after migration.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

Usage guidelines

·     If the number of drives required for the target level of migration is more than the original level, you must first add drives to the LD and then perform migration.

·     To migrate RAID 1 to RAID 5, you cannot add drives directly to RAID 1. First migrate RAID 1 to RAID 0, add drives, and then migrate RAID 0 to RAID 5.

Examples

# Migrate RAID 0 to RAID 5.

[root@localhost ~]# arcconf modify 1 from 0 to 305190 5 0 0 0 1 0 6 0 7
Controllers found: 1
Reconfiguration of a logical device is a long process.  Are you sure you want to continue?
Press y, then ENTER to continue or press ENTER to abort: y
 
Reconfiguring logical device: LogicalDrv 0
 
Command completed successfully.

# View the migration process.

[root@localhost ~]# arcconf getconfig 1 ld
Controllers found: 1
----------------------------------------------------------------------
Logical device information
----------------------------------------------------------------------
Logical Device number 0
   Logical Device name                      : LogicalDrv 0
   Disk Name                                : /dev/sda
   Block Size of member drives              : 512 Bytes
   Array                                    : 0
   RAID level                               : 5
   Status of Logical Device                 : Optimal(Background Parity Initialization : 51 %)
   Parity Initialization Status             : In Progress
   Size                                     : 305190 MB
   Stripe-unit size                         : 256 KB
   Full Stripe Size                         : 768 KB
   Interface Type                           : SATA SSD
   Device Type                              : Data
   Boot Type                                : None
   Heads                                    : 255
   Sectors Per Track                        : 32
   Cylinders                                : 65535
   Caching                                  : Enabled
   Mount Points                             : Not Applicable
   LD Acceleration Method                   : Controller Cache
   Volume Unique Identifier                 : 600508B1001C7B7C4BBF3ACB01F885BC
   --------------------------------------------------------
   Array Physical Device Information
   --------------------------------------------------------
   Device 0                                 : Present (152627MB, SATA, SSD, Channel:0, Device:0) CVPR1461036N160DGN
   Device 1                                 : Present (1526185MB, SATA, SSD, Channel:0, Device:1) PHDV624000FL1P6EGN
   Device 6                                 : Present (457862MB, SATA, SSD, Channel:0, Device:6)         17501B83246B
   Device 7                                 : Present (915715MB, SATA, SSD, Channel:0, Device:7)         18031A983BCA
 
 
 
 
Command completed successfully.

Setting the drive initialization or uninitialization state

Perform this task to set the drive initialization or uninitialization state.

Syntax

arcconf task start controller_id device channel_id device_id type

Parameters

controller_id: Specifies the ID of the storage controller.

channel_id: Specifies the channel ID of the drive. To obtain the channel ID, use the arcconf getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output represent the channel and ID.

device_id: Specifies the drive ID. To obtain the drive ID, use the arcconf getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output represent the channel and ID.

type: Specifies the task type. Options include initialize and uninitialize.

Usage guidelines

If you specify all as the channel_id device_id, the command initializes or uninitializes all drives managed by the storage controller.

Examples

# Set the drive with device ID 9 for storage controller 1 to initialized state.

[root@localhost ~]# arcconf task start 1 device 0 9 initialize

Controllers found: 1

Initializing Channel 0, Device 9 will erase its metadata, the section

where all the logical device definition data is stored

 

Are you sure you want to continue?

Press y, then ENTER to continue or press ENTER to abort: y

 

Initializing Channel 0, Device 9.

 

Command completed successfully.

Viewing the rebuild function state of hot spare drives

Perform this task to view the rebuild function state of hot spare drives.

Syntax

arcconf getconfig controller_id AL |grep -i failover

Parameters

controller_id: Specifies the ID of the storage controller.

Examples

# View the rebuild function state of hot spare drives of storage controller 1.

[root@localhost ~]# arcconf  getconfig 1 AL |grep -i failover

  Automatic Failover                         : Enabled

Enabling or disabling the rebuild function of hot spare drives

Perform this task to enable or disable the rebuild function of hot spare drives.

Syntax

arcconf failover controller_id status

Parameters

controller_id: Specifies the ID of the storage controller.

status: Specifies the action. Options include on and off.

Examples

# Disable the rebuild function of hot spare drives for storage controller 1.

[root@localhost ~]# arcconf failover 1 off

Controllers found: 1

 

Command completed successfully.

Configuring hot spare drives

Perform this task to configure global hot spare drives, dedicated hot spare drives, and pooled hot spare drives.

Syntax

arcconf setstate controller_id device channel_id device_id hsp

arcconf setstate controller_id device channel_id device_id hsp logicaldrive ld_id

Parameters

controller_id: Specifies the ID of the storage controller.

channel_id: Specifies the channel ID of the drive. To obtain the channel ID, use the arcconf getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output represent the channel and ID.

device_id: Specifies the drive ID. To obtain the drive ID, use the arcconf getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output represent the channel and ID.

ld_id: Specifies the ID of the logical drive. To obtain the ID, use the arcconf getconfig controller_id pd command. The Logical Device number field in the output represents the logical drive ID.

Examples

# Specify the drive with device ID 33 as a global hot spare drive.

[root@localhost ~]# arcconf setstate 1 device 0 33 hsp

Controllers found: 1

This global hot spare will only protect logicals whose member block size is 512 Bytes.

 

Command completed successfully.

# Specify the drive with device ID 34 as the dedicated hot spare drive of the logical drive with ID 0.

[root@localhost ~]# arcconf setstate 1 device 0 34 hsp logicaldrive 0

Controllers found: 1

 

Command completed successfully.

# Specify the drive with device ID 36 as a pooled hot spare drive of logical drives with ID 0 and 1.

[root@localhost ~]# arcconf setstate 1 device 0 36 hsp logicaldrive 0 1

Controllers found: 1

 

Command completed successfully.

Deleting a hot spare drive

Perform this task to delete a hot spare drive.

Syntax

arcconf setstate controller_id device channel_id device_id rdy

Parameters

controller_id: Specifies the ID of the storage controller.

channel_id: Specifies the channel ID of the drive. To obtain the channel ID, use the arcconf getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output represent the channel and ID.

device_id: Specifies the drive ID. To obtain the drive ID, use the arcconf getconfig controller_id pd command. The Reported Channel and Device (T:L) fields in the output represent the channel and ID.

Examples

# Delete the hot spare drive with ID 47.

[root@localhost ~]# arcconf setstate 1 device 0 47 rdy

Controllers found: 1

 

Command completed successfully.

Collecting logs

Perform this task to collect storage controller logs.

Syntax

arcconf savesupportarchive path

Parameters

path: Specifies the path for storing the log file.

Examples

# Collect storage controller logs and save the log in the home directory.

[root@localhost ~]# arcconf savesupportarchive /home

Controllers found: 1

 

Collecting uart logs may take few seconds...

The logs are saved in relevant folders in /home/Support

 

Command completed successfully.

Enabling or disabling LD cache

Perform this task to enable or disable the LD cache feature.

Syntax

Command

Function

arcconf setcache controller_id logicaldrive LD_id con

Enable cache for the specified LD.

arcconf setcache controller_id logicaldrive LD_id coff

Disable cache for the specified LD.

arcconf setcache controller_id logicaldrive LD_id ron

Enable read-cache for the specified LD.

arcconf setcache controller_id logicaldrive LD_id roff

Disable read-cache for the specified LD.

arcconf setcache controller_id logicaldrive LD_id wt

Set the cache write policy to write through for the specified LD. This operation disables write-cache for the controller.

arcconf setcache controller_id logicaldrive LD_id wb

Set the cache write policy to write back for the specified LD. This operation enables the system to enable RAID group write cache even if no supercapacitor is present. This might cause data loss in the event of unexpected power-off.

arcconf setcache controller_id logicaldrive LD_id wbb

Set the cache write policy to write back with battery/ZMM for the specified LD. This operation enables the system to automatically disable RAID group write cache when no supercapacitor is present or the supercapacitor is not ready. This configuration is recommended.

 

Parameters

controller_id: Specifies the ID of the storage controller.

LD_id: Specifies the ID of a logical drive.

Examples

# Enable cache for LD 0.

[root@localhost Firmware]# arcconf setcache 1 logicaldrive 0 con

Controllers found: 1

 

Command completed successfully.

# Disable cache for LD 0.

[root@localhost ~]# arcconf setcache 1 logicaldrive 0 coff

Controllers found: 1
 
Command completed successfully.

# Enable read-cache for LD 0.

[root@localhost Firmware]# ./arcconf setcache 1 logicaldrive 0 ron

Controllers found: 1

 

Command completed successfully.

# Disable read-cache for LD 0.

[root@localhost Firmware]# ./arcconf setcache 1 logicaldrive 0 roff

Controllers found: 1

 

Command completed successfully.

# Set the cache write policy for LD 0 to write through.

[root@localhost Firmware]# arcconf setcache 1 logicaldrive 0 wt

Controllers found: 1

 

Command completed successfully.

# Set the cache write policy for LD 0 to write back.

[root@localhost Firmware]# arcconf setcache 1 logicaldrive 0 wb

Controllers found: 1

WARNING: Power failure without battery/ZMM support will lead to data loss.

Do you wish to continue?

Press y, then ENTER to continue or press ENTER to abort: y

 

Command completed successfully.

# Set the cache write policy for LD 0 to write back with battery/ZMM.

[root@localhost Firmware]# ./arcconf setcache 1 logicaldrive 0 wbb

Controllers found: 1

 

Command completed successfully.

# View the read and write cache settings of LD 0.

[root@localhost Firmware]# ./arcconf getconfig 1 ld 0

Controllers found: 1

----------------------------------------------------------------------

Logical device information

----------------------------------------------------------------------

Logical Device number 0

   Logical Device name                        : DefaultValue00

   Block Size of member drives                : 512 Bytes

   RAID level                                 : 1

   Unique Identifier                          : 8E1725B7

   Status of Logical Device                   : Optimal

   Additional details                         : Quick initialized

   Size                                       : 102390 MB

   Parity space                               : 102400 MB

   Interface Type                             : Serial Attached SCSI

   Device Type                                : HDD

   Read-cache setting                         : Enabled

   Read-cache status                          : On

   Write-cache setting                        : On when protected by battery/ZMM

   Write-cache status                         : On

   Partitioned                                : No

   Protected by Hot-Spare                     : No

   Bootable                                   : Yes

   Failed stripes                             : No

   Power settings                             : Disabled

   --------------------------------------------------------

   Logical Device segment information

   --------------------------------------------------------

   Segment 0                                  : Present (17166336MB, SAS, HDD, Enclosure:0, Slot:9) ZR50AQ6W0000C1095DHV

   Segment 1                                  : Present (17166336MB, SAS, HDD, Enclosure:0, Slot:10) ZR50AQG70000C101J4WN

 

 

 

Command completed successfully.

Erasing data on a data disk

Perform this task to start or stop erasing data on a data disk.

Syntax

arcconf task start controller_id device channel_id device_id secureerase

arcconf task stop controller_id device channel_id device_id

Parameters

controller_id: Specifies the ID of the storage controller.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

Examples

# Start to erase data on the physical drive with device ID 15.

[root@localhost Firmware]# arcconf task start 1 device 0 15 secureerase

Controllers found: 1

Secure erase of a Hard drive is a long process.

Warning: Rebooting the machine would stop the Secure erase task.

 

Are you sure you want to continue?

Press y, then ENTER to continue or press ENTER to abort: y

 

Secure Erasing Channel 0, Device 15.

 

Command completed successfully.

# Stop erasing data on the physical drive with device ID 15.

[root@localhost Firmware]# arcconf task stop 1 device 0 15

Controllers found: 1

 

Command completed successfully.

Forcing a physical drive to go offline

Perform this task to force a physical to go offline.

Syntax

arcconf setstate controller_id device channel_id device_id DDD

Parameters

controller_id: Specifies the ID of the storage controller.

channel_id: Specifies the channel ID of a drive.

device_id: Specifies the device ID of a drive.

Examples

# Force the physical drive with device ID 14 to go offline.

[root@localhost ~]# arcconf setstate 1 device 0 14 DDD

Controllers found: 1

Changing state from Ready to Failed may delete any data partitions present on the drive.

 

Are you sure you want to continue?

Press y, then ENTER to continue or press ENTER to abort: y

 

 

Command completed successfully.

Configuring consistency check

Perform this task to enable and configure consistency check.

Syntax

arcconf consistencycheck controller_id mode

arcconf consistencycheck controller_id parallelcount parallelcount_number

Parameters

controller_id: Specifies the ID of the storage controller.

mode: Specifies the action. Options include:

·     on: Enable consistency check.

·     off: Disable consistency check.

parallelcount_number: Specifies the number of consistency check concurrencies at the backstage. Setting this value to 1 disables concurrent consistent check.

Examples

# Enable consistency check and set the number of concurrencies to 4.

[root@localhost ~]# arcconf consistencycheck 1 on
Controllers found: 1
 
Command completed successfully.

[root@localhost ~]# arcconf consistencycheck 1 parallelcount 4
Controllers found: 1
 
Command completed successfully.

Troubleshooting

For detailed information about collecting storage controller fault information, diagnosing and locating faults, and troubleshooting servers, see H3C Servers Troubleshooting Guide.

Compatibility

For information about storage controller and server compatibility, access http://www.h3c.com/en/home/qr/default.htm?id=66.

Downloading and installing drivers

Access the H3C official website to download the storage controller drivers. For more information about installing drivers, see the release notes for the driver program.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网