- Table of Contents
-
- H3C Network Adapter Datasheet-6W103
- 00-Preface
- 01-About H3C Network Adapters
- 02-PCIe network adapter specifications
- 03-FLOM network adapter specifications
- 04-mLOM network adapter specifications
- 05-sLOM network adapter specifications
- 06-OCP network adapter specifications
- 07-Appendix A Safety standards&EMC standards&Acronyms
- 08-Appendix B FAQs
- Related Documents
-
Title | Size | Download |
---|---|---|
02-PCIe network adapter specifications | 1.48 MB |
PCIe network adapter specifications
The figures in this section are for illustration only.
PCIe network adapter list
Table 1 PCIe network adapters
Model |
Description |
CNA-10GE-2P-510F-B2 |
2-port 10Gb/s PCIe3.0 x8 SFP+ fiber interface 510F LP converged network adapter (Chelsio T5) |
NIC-10GE-2P-520F-B2 |
2-port 10Gb/s PCIe3.0 x8 SFP+ fiber interface 520F LP Ethernet adapter (Mellanox CX3) |
NIC-10GE-2P-530F-B2 |
2-port 10Gb/s PCIe2.0 x8 SFP+ fiber interface 530F LP Ethernet adapter (Qlogic B57810) |
CNA-10GE-2P-560F-B2 |
2-port 10Gb/s PCIe2.0 x8 SFP+ fiber interface 560F LP converged network adapter (Intel 82599) |
NIC-GE-4P-360T-B2 |
4-port 1Gb/s PCIe2.0 x4 copper interface 360T LP Ethernet adapter (Intel i350) |
CNA-560T-B2-10Gb-2P |
2-port 10Gb/s PCIe3.0 x4 copper interface 560T LP converged network adapter (Intel X550) |
NIC-620F-B2-25Gb-2P |
2-port 25Gb/s PCIe3.0 x8 SFP28 fiber interface 620F LP Ethernet adapter (Mellanox CX4-LX) |
NIC-ETH540F-LP-2P |
2-port 10Gb/s PCIe3.0 x8 SFP+ fiber interface ETH540F LP Ethernet adapter (Mellanox CX4-LX) |
NIC-ETH1040F-LP-2P |
2-port 100Gb/s PCIe4.0 x16 QSFP56 fiber interface ETH1040F LP Ethernet adapter (Mellanox CX6-DX) |
NIC-ETH1060F-LP-2P |
2-port 100Gb/s PCIe4.0 x16 QSFP28 fiber interface ETH1060F LP Ethernet adapter (Intel E810) |
NIC-ETH531F-LP-2P |
2-port 10Gb/s PCIe3.0 x8 SFP+ fiber interface ETH531F LP Ethernet adapter (Broadcom BCM57412) |
NIC-ETH630F-LP-2P |
2-port 25Gb/s PCIe3.0 x8 SFP28 fiber interface ETH630F LP Ethernet adapter (Broadcom BCM57414) |
NIC-ETH641F-LP-2P |
2-port 25Gb/s PCIe4.0 x8 SFP28 fiber interface ETH641F LP Ethernet adapter (Mellanox CX6-LX) |
NIC-ETH330T-LP-4P |
4-port 1Gb/s PCIe2.0 x4 copper interface ETH330T LP Ethernet adapter (Broadcom BCM5719) |
CNA-10GE-2P-510F-B2
Figure 1 CNA-10GE-2P-510F-B2
Ports and LEDs
Figure 2 CNA-10GE-2P-510F-B2 front panel
(1) SFP+ fiber port ACT LED |
(2) SFP+ fiber port LINK LED |
(3) 10-GE SFP+ fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 2 CNA-10GE-2P-510F-B2 technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Chelsio T5 |
Maximum power consumption |
25 W |
Bus type |
PCIe3.0 ×8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 10-GE SFP+ |
Data rate |
10 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ab, 802.3u, 802.3x, 802.3ad, 802.1q, 802.3az |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 3 CNA-10GE-2P-510F-B2 features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
√** |
iSCSI |
√ |
SRIOV |
√* |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√* |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
× |
RDMA over Converged Ethernet version 1 (RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
× |
Internet Wide Area RDMA Protocol (iWARP) |
√* |
NPAR |
× |
NCSI |
× |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
× |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Two asterisks (**) indicate that the feature is not available for H3C CAS or VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. |
NIC-10GE-2P-520F-B2
Figure 3 NIC-10GE-2P-520F-B2
Ports and LEDs
Figure 4 NIC-10GE-2P-520F-B2 front panel
(1) SFP+ fiber port ACT LED |
(2) SFP+ fiber port LINK LED |
(3) 10-GE SFP+ fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 4 NIC-10GE-2P-520F-B2 technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Mellanox ConnectX-3 Pro |
Maximum power consumption |
10 W |
Bus type |
PCIe3.0 ×8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 10-GE SFP+ |
Data rate |
10 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ab, 802.3u, 802.3x, 802.3ad, 802.1q, 802.3az |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 5 NIC-10GE-2P-520F-B2 features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
|
iSCSI |
√ |
SRIOV |
√** |
VMDq |
√** |
Multiple Rx Queues (RSS) |
√** |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√** |
Wake-on-LAN |
× |
RDMA over Converged Ethernet version 1 (RoCE v1) |
√* |
RDMA over Converged Ethernet version 2(RoCE v2) |
√* |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
× |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
× |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Two asterisks (**) indicate that the feature is not available for H3C CAS or VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · iSCSI is not available for H3C CAS. |
NIC-10GE-2P-530F-B2
Figure 5 NIC-10GE-2P-530F-B2
Ports and LEDs
Figure 6 NIC-10GE-2P-530F-B2 front panel
(1) SFP+ fiber port ACT LED |
(2) SFP+ fiber port LINK LED |
(3) 10GE SFP+ fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 6 NIC-10GE-2P-530F-B2 technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Qlogic BCM57810S |
Maximum power consumption |
10 W |
Bus type |
PCIe2.0 ×8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 1/10GE SFP/SFP+ |
Data rate |
1/10 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ab, 802.3u, 802.3x, 802.3ad, 802.1q, 802.3az |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 7 NIC-10GE-2P-530F-B2 features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√ |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
× |
RDMA over Converged Ethernet version 1 (RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
× |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
√ |
NCSI |
× |
NIC bonding |
√ |
DPDK |
× |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. |
CNA-10GE-2P-560F-B2
Figure 7 CNA-10GE-2P-560F-B2
Ports and LEDs
Figure 8 CNA-10GE-2P-560F-B2 front panel
(1) SFP+ fiber port ACT LED |
(2) SFP+ fiber port LINK LED |
(3) 10GE SFP+ fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 8 CNA-10GE-2P-560F-B2 technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Intel JL82599ES |
Maximum power consumption |
15 W |
Bus type |
PCIe2.0 ×8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 1/10GE SFP/SFP+ |
Data rate |
1/10 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ab, 802.3u, 802.3x, 802.3ad, 802.1q, 802.3az |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 9 CNA-10GE-2P-560F-B2 features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
√** |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√ |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
× |
RDMA over Converged Ethernet version 1(RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
× |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
× |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
× |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Two asterisks (**) indicate that the feature is not available for H3C CAS or VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. |
NIC-GE-4P-360T-B2
Figure 9 NIC-GE-4P-360T-B2
Ports and LEDs
Figure 10 NIC-GE-4P-360T-B2 front panel
(1) RJ-45 copper port LINK LED |
(2) RJ-45 copper port ACT LED |
(3) 10/100/1000Base-T autosensing Ethernet ports 1 through 4 (from left to right) |
|
NOTE: For information about the copper port LEDs, see Table 31. |
Technical specifications
Table 10 NIC-GE-4P-360T-B2 technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Intel NHI350AM4 |
Maximum power consumption |
5 W |
Bus type |
PCIe2.0 ×4 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
4 × RJ-45 |
Data rate |
10/100/1000 Mbit/s |
Transmission media |
STP cable |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ab, 802.3u, 802.3x, 802.3ad, 802.1q, 802.3az |
Features
Table 11 NIC-GE-4P-360T-B2 features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√* |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√* |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
× |
Wake-on-LAN |
× |
RDMA over Converged Ethernet version 1(RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
× |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
× |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
× |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. |
CNA-560T-B2-10Gb-2P
Figure 11 CNA-560T-B2-10Gb-2P
Ports and LEDs
Figure 12 CNA-560T-B2-10Gb-2P front panel
(1) RJ-45 copper port LINK LED |
(2) RJ-45 copper port ACT LED |
(3) 1/10Gbit/s autosensing Ethernet ports (2 in total) |
|
NOTE: For information about the copper port LEDs, see Table 31. |
Technical specifications
Table 12 CNA-560T-B2-10Gb-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Intel ELX550AT2SLL2E |
Maximum power consumption |
12 W |
Bus type |
PCIe3.0 ×4 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × RJ-45 |
Data rate |
1/10 Gbit/s |
Transmission media |
STP cable |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3u, 802.3x, 802.1q, 802.3az, 802.3an, 802.3bz, 802.3ac, 802.1Qbb, 802.1Qaz, 802.1p |
Features
Table 13 CNA-560T-B2-10Gb-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√ |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
× |
RDMA over Converged Ethernet version 1(RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
× |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
× |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
× |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. |
NIC-620F-B2-25Gb-2P
Figure 13 NIC-620F-B2-25Gb-2P
Ports and LEDs
Figure 14 NIC-620F-B2-25Gb-2P ports and LEDs
(1) NCSI connector |
(2) SFP28 fiber port ACT LED |
(3) SFP28 fiber port LINK LED |
(4) 25-GE SFP28 fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 14 NIC-620F-B2-25Gb-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Mellanox ConnectX-4 Lx (MT27712A0-FDCF-AE) |
Maximum power consumption |
12 W |
Bus type |
PCIe3.0 ×8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 25GE SFP28 and 1 × NCSI |
Data rate |
1/10/25 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ad, 802.3az, 802.3ae, 802.3ap, 802.1Q, 802.1p, 802.1Qau, 802.1Qbb, 802.1Qbg, and IEEE802.3BYY2016 |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 15 NIC-620F-B2-25Gb-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1(RoCE v1) |
√ |
RDMA over Converged Ethernet version 2 (RoCE v2) |
√ |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH540F-LP-2P
Figure 15 NIC-ETH540F-LP-2P
Ports and LEDs
Figure 16 NIC-ETH540F-LP-2P ports and LEDs
(1) NCSI connector |
(2) SFP+ fiber port ACT LED |
(3) SFP+ fiber port LINK LED |
(4) 10-GE SFP+ fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 16 NIC-ETH540F-LP-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Mellanox ConnectX-4 Lx (MT27712A0-FDCF-XE) |
Maximum power consumption |
12 W |
Bus type |
PCIe3.0 ×8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 10-GE SFP and 1 × NCSI |
Data rate |
10 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ad, 802.3az, 802.3ae, 802.3ap, 802.1Q, 802.1p, 802.1Qau, 802.1Qbb, 802.1Qbg |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 17 NIC-ETH540F-LP-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1(RoCE v1) |
√ |
RDMA over Converged Ethernet version 2 (RoCE v2) |
√ |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH1040F-LP-2P
Figure 17 NIC-ETH1040F-LP-2P
Ports and LEDs
Figure 18 NIC-ETH1040F-LP-2P ports and LEDs
(1) QSFP56 fiber port ACT LED |
(2) QSFP56 fiber port LINK LED |
(3) QSFP56 fiber port LINK LED |
(4) QSFP56 fiber port ACT LED |
(5) 100-GE QSFP56 fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 33. |
Technical specifications
Table 18 NIC-ETH1040F-LP-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Mellanox ConnectX-6 Dx (MT28928A0-NCCF-CE) |
Maximum power consumption |
27.31 W |
Bus type |
PCIe4.0 x16 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 100-GE QSFP56 |
Data rate |
100 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3x, 802.3bs, 802.3cd, 802.3bj, 802.3bm, 802.3by, 802.3ba, 802.3ae, 802.3az, 802.3ap, 802.3ad, 802.1AX, 802.1Q, 802.1P, 802.1Qaz, 802.1Qbb, 802.1Qbg |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 19 NIC-ETH1040F-LP-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues(RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine(TOE) |
√* |
Wake-on-LAN |
× |
RoCE v1 (RDMA over Converged Ethernet version 1) |
√ |
RoCE v2 (RDMA over Converged Ethernet version 2) |
√ |
iWARP (Internet Wide Area RDMA Protocol) |
× |
NPAR |
× |
NCSI |
× |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH1060F-LP-2P
Figure 19 NIC-ETH1060F-LP-2P
Ports and LEDs
Figure 20 NIC-ETH1060F-LP-2P ports and LEDs
(1) 100-GE QSFP28 fiber ports (2 in total) |
(2) QSFP28 fiber port LINK/ACT LED |
|
NOTE: For information about the fiber port LEDs, see Table 32. |
Technical specifications
Table 20 NIC-ETH1060F-LP-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
E810-CAM2 |
Maximum power consumption |
25 W |
Bus type |
PCIe4.0 x16 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 100GE QSFP28 and 1 × NCSI |
Data rate |
100 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex in active/standby mode |
Standards |
802.3, 802.3bd, 802.3ae, 802.3an, 802.3ap, 802.3az, 802.3ba, 802.3z |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 21 NIC-ETH1060F-LP-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√ |
Multiple Rx Queues (RSS) |
√* |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1(RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
√ |
Internet Wide Area RDMA Protocol (iWARP) |
√ |
NPAR |
× |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH531F-LP-2P
Figure 21 NIC-ETH531F-LP-2P
Ports and LEDs
Figure 22 NIC-ETH531F-LP-2P ports and LEDs
(1) Network adapter NCSI connector |
(2) SFP+ fiber port ACT LED |
(3) SFP+ fiber port LINK LED |
(4) 10-GE SFP+ fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 22 NIC-ETH531F-LP-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
BCM57412 |
Maximum power consumption |
10 W |
Bus type |
PCIe3.0 x8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 10GE SFP+ and 1 × NCSI |
Data rate |
10 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex in active/standby mode |
Standards |
802.3, 802.3x, 802.3ad, 802.3az, 802.3u, 802.1q, 802.1Qbb, 802.1Qaz, 802.1Qau |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 23 NIC-ETH531F-LP-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1(RoCE v1) |
√ |
RDMA over Converged Ethernet version 2 (RoCE v2) |
√ |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
√ |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH630F-LP-2P
Figure 23 NIC-ETH630F-LP-2P
Ports and LEDs
Figure 24 NIC-ETH630F-LP-2P ports and LEDs
(1) Network adapter NCSI connector |
(2) SFP28 fiber port ACT LED |
(3) SFP28 fiber port LINK LED |
(4) 25-GE SFP28 fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 24 NIC-ETH630F-LP-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
BCM57414 |
Maximum power consumption |
13 W |
Bus type |
PCIe3.0 x8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 25GE SFP28 and 1 × NCSI |
Data rate |
25 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3x, 802.3ad, 802.3az, 802.3u, 802.1q, 802.1Qbb, 802.1Qaz, 802.1Qau |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 25 NIC-ETH630F-LP-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1 (RoCE v1) |
√ |
RDMA over Converged Ethernet version 2 (RoCE v2) |
√ |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
√ |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH641F-LP-2P
Figure 25 NIC-ETH641F-LP-2P
Ports and LEDs
Figure 26 NIC-ETH641F-LP-2P ports and LEDs
(1) Network adapter NCSI connector |
(2) SFP28 fiber port ACT LED |
(3) SFP28 fiber port LINK LED |
(4) 25-GE SFP28 fiber ports (2 in total) |
|
NOTE: For information about the fiber port LEDs, see Table 30. |
Technical specifications
Table 26 NIC-ETH641F-LP-2P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
Mellanox ConnectX-6 Lx (MT28942A0-NCCF-AE) |
Maximum power consumption |
13 W |
Bus type |
PCIe4.0 x8 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
2 × 25GE SFP28 and 1 × NCSI |
Data rate |
25 Gbit/s |
Transmission media |
Optical fiber |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3x, 802.3ae, 802.3by, 802.3ad, 802.1AX, 802.3az, 802.3ap, 802.1Q, 802.1P, 802.1Qaz, 802.1Qbb, 802.1Qbg |
Available transceiver modules |
See "About H3C Network Adapters." |
Features
Table 27 NIC-ETH641F-LP-2P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
√ |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1(RoCE v1) |
√ |
RDMA over Converged Ethernet version 2 (RoCE v2) |
√ |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
√*** |
IPv6 |
√ |
LLDP |
√ |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
NIC-ETH330T-LP-4P
Figure 27 NIC-ETH330T-LP-4P
Ports and LEDs
Figure 28 NIC-ETH330T-LP-4P ports and LEDs
(1) RJ-45 copper port LINK LED |
(2) RJ-45 copper port ACT LED |
(3) 10/100/1000Base-T autosensing Ethernet ports (4 in total) |
|
NOTE: For information about the copper port LEDs, see Table 31. |
Technical specifications
Table 28 UN-NIC-ETH330T-LP-4P technical specifications
Item |
Specifications |
Basic properties |
|
Chip model |
BCM5719A1KFBG |
Maximum power consumption |
8 W |
Bus type |
PCIe2.0 x4 |
Form factor |
LP By default, the network adapter comes with a full-height bracket installed. You can install a half-height bracket instead. |
Network properties |
|
Connectors |
4 × RJ-45 |
Data rate |
10/100/1000 Mbit/s |
Transmission media |
Twisted pair cables |
Duplex mode |
Full duplex |
Standards |
802.3, 802.3ab, 802.3u, 802.3x, 802.3ap, 802.1q, 802.3az |
Features
Table 29 NIC-ETH330T-LP-4P features
Feature |
Supported or not |
Jumbo Frames |
√ |
Load Balancing |
√ |
802.1Q VLANs |
√ |
Auto-Negotiation |
√ |
FCoE |
× |
iSCSI |
√ |
SRIOV |
× |
VMDq |
√* |
Multiple Rx Queues (RSS) |
√ |
TCP/IP Stateless Offloading |
√* |
TCP/IP Offload Engine (TOE) |
√* |
Wake-on-LAN |
√ |
RDMA over Converged Ethernet version 1(RoCE v1) |
× |
RDMA over Converged Ethernet version 2 (RoCE v2) |
× |
Internet Wide Area RDMA Protocol (iWARP) |
× |
NPAR |
× |
NCSI |
√ |
NIC bonding |
√ |
DPDK |
× |
IPv6 |
√ |
LLDP |
× |
LLDP Pass-through |
√ |
Remote boot |
|
PXE Boot |
√ |
FCoE Boot |
× |
iSCSI Boot |
× |
|
NOTE: · One asterisk (*) indicates that the feature is not available for VMware ESXi. · Three asterisks (***) indicate that the feature is available only for Linux and BSD. · Only one port on the network adapter supports NCSI at a time. |
LEDs
Table 30 SFP+/SFP28 port status LED description
Status |
Description |
|
LINK (amber) |
ACT (green) |
|
Steady on |
Flashing |
The port is sending or receiving data. |
Steady on |
Off |
A link is present, but the port is not sending or receiving data. |
Off |
Off |
No link is present. |
Table 31 RJ-45 port status LED description
Status |
Description |
|
LINK (green) |
ACT (green) |
|
Steady on |
Flashing |
The port is sending or receiving data. |
Steady on |
Off |
A link is present, but the port is not sending or receiving data. |
Off |
Off |
No link is present. |
Table 32 QSFP28 port status LED description for NIC-ETH1060F-LP-2P
Status |
Description |
Steady green |
A 100-GE link is present, but no data is being sent or received |
Flashing green |
A 100-GE link is present, and the port is sending or receiving data. |
Off |
No link is present. |
Table 33 QSFP56 port status LED description for NIC-ETH1040F-LP-2P
Status |
LINK LED status and description |
ACT LED status and description |
Error |
Flashing yellow (4 Hz): Indicates that an error occurs on the link. The following are possible causes for the error: · I²C access to the network port fails. · An overcurrent condition occurs on the network port. |
Steady green |
The link is connected and is receiving or transmitting data |
· Steady green: The port operates at a rate of 100G. · Steady yellow: The port operates at a rate less than 100G. |
Flashing green |
The link is connected but is not receiving or transmitting data |
· Steady green: The port operates at a rate of 100G. · Steady yellow: The port operates at a rate less than 100G. |
Steady green |