Title | Size | Download |
---|---|---|
02-Appendix A Chassis views and technical specifications | 1.32 MB |
Contents
1 Appendix A Chassis views and technical specifications
Network data encryption modules
Network data encryption modules
Network data encryption modules
1 Appendix A Chassis views and technical specifications
Chassis views
F1003-C/F1003-S
The F1003-C or F1003-S firewall provides the following ports on the front panel:
· Two 1000BASE-X Ethernet fiber ports.
· Five 10/100/1000BASE-T autosensing Ethernet copper ports (including one management Ethernet port).
· One USB port.
· One console port.
· One reset button.
· One Micro SD card slot.
Figure1-1 Front panel
(1) 10/100/1000BASE-T Ethernet copper ports |
(2) 1000BASE-X Ethernet fiber ports |
(3) Console port |
(4) Reset button (for device reboot only, and does not restore the factory default) |
(5) LEDs |
(6) Power adapter receptacle |
(7) Micro SD card slot |
(8) USB port (host mode, Type A connector) |
(9) Management Ethernet port (MGMT) |
Figure1-2 Rear panel
(1) Grounding screw |
F1003-M
The F1003-M firewall provides the following ports on the front panel:
· Two 1000BASE-X Ethernet fiber ports.
· Ten 10/100/1000BASE-T autosensing Ethernet copper ports (including one management Ethernet port).
· One USB port.
· One console port.
· One reset button.
· One Micro SD card slot.
Figure1-3 Front panel
(1) 10/100/1000BASE-T Ethernet copper ports |
(2) 1000BASE-X Ethernet fiber ports |
(3) Console port |
(4) Reset button (for device reboot only, and does not restore the factory default) |
(5) LEDs |
(6) Power adapter receptacle |
(7) Micro SD card slot |
(8) USB port (host mode, Type A connector) |
(9) Management Ethernet port (0/MGMT) |
Figure1-4 Rear panel
(1) Grounding screw |
F1005/F1010
The F1005 or F1010 firewall provides the following ports on the front panel:
· Eight 10/100/1000BASE-T autosensing Ethernet copper ports.
· Two bypass ports.
· Two combo interfaces.
· Two USB ports.
· One console port.
· One drive slot.
Figure1-5 Front panel
(1) Drive slot |
(2) Console port |
(3) USB ports (host mode, Type A connector) |
(4) Combo interfaces |
(5) Bypass ports |
(6) 10/100/1000BASE-T Ethernet copper ports |
(7) LEDs |
(8) Management Ethernet port (0/MGMT) |
(1) Grounding screw |
(2) Power receptacle |
F1020
The F1020 firewall provides the following ports on the front panel:
· Sixteen 10/100/1000BASE-T autosensing Ethernet copper ports.
· Eight 1000BASE-X Ethernet fiber ports.
· Two USB ports.
· One console port.
· One drive slot.
Figure1-7 Front panel
(1) Drive slot |
(2) LEDs |
(3) 10/100/1000BASE-T Ethernet copper ports |
(4) 1000BASE-X Ethernet fiber ports |
(5) Console port |
(6) USB ports (host mode, Type A connector) |
(7) Management Ethernet port (0/MGMT) |
Figure1-8 Rear panel
(1) Power receptacle |
(2) Interface module slot 1 |
(3) Interface module slot 2 (not supported) |
(4) Grounding screw |
F1030/F1050/F1060
The F1030, F1050, or F1060 firewall provides the following ports on the front panel:
· Sixteen 10/100/1000BASE-T autosensing Ethernet copper ports.
· Eight 1000BASE-X Ethernet fiber ports.
· Two USB ports.
· One console port.
· One drive slot.
Figure1-9 Front panel
(1) Drive slot |
(2) LEDs |
(3) 10/100/1000BASE-T Ethernet copper ports |
(4) 1000BASE-X Ethernet fiber ports |
(5) Console port |
(6) USB ports (host mode, Type A connector) |
(7) Management Ethernet port (0/MGMT) |
Figure1-10 Rear panel
(1) Power receptacle |
(2) Interface module slot 1 |
(3) Interface module slot 2 (not supported) |
(4) Grounding screw |
F1070/F1080
The F1070 or F1080 firewall provides the following ports on the front panel:
· Sixteen 10/100/1000BASE-T autosensing Ethernet copper ports.
· Eight 1000BASE-X Ethernet fiber ports.
· Two 10GBASE-R Ethernet fiber ports.
· Two USB ports.
· One console port.
· Two drive slots.
Figure1-11 Front panel
(1) Drive slots |
(2) LEDs |
(3) 10/100/1000BASE-T Ethernet copper ports |
(4) 1000BASE-X Ethernet fiber ports |
(5) 10GBASE-R Ethernet fiber ports |
(6) Console port |
(7) USB ports (host mode, Type A connector) |
(8) Management Ethernet port (0/MGMT) |
Figure1-12 Rear panel
(1) Power module slot 0 |
(2) Power module slot 1 |
(3) Interface module slot 1 |
(4) Interface module slot 2 |
(5) Grounding screw |
F1090
The F1090 firewall provides the following ports on the front panel:
· Fourteen 10/100/1000BASE-T autosensing Ethernet copper ports.
· Eight 1000BASE-X Ethernet fiber ports.
· Eight 10GBASE-R Ethernet fiber ports.
· Two USB ports.
· One console port.
· One micro USB port.
· Two drive slots.
· Two management Ethernet ports.
Figure1-13 Front panel
(1) Drive slots |
(2) Management Ethernet port (1/MGMT) |
(3) 10/100/1000BASE-T Ethernet copper ports |
(4) 10GBASE-R Ethernet fiber ports |
(5) 1000BASE-X Ethernet fiber ports |
(6) LEDs |
(7) Reset button (for device reboot only, and does not restore the factory default) |
(8) Micro USB console port |
(9) USB port (host mode, Type A connector) |
(10) Console port |
(11) Management Ethernet port (0/MGMT) |
Figure1-14 Rear panel
(1) Power module slot 1 |
(2) Power module slot 2 |
(3) Interface module slot 2 |
(4) Interface module slot 4 |
(5) Grounding screw |
(6) Interface module slot 3 |
(7) Interface module slot 1 |
Interface modules
Table1-1 displays the slots available for interface module installation.
Table1-1 Interface module and device slot compatibility
Firewall model |
Slot number |
Slot specification |
Available interface modules |
F1003-C/F1003-S/F1003-M/F1005/F1010 |
N/A |
N/A |
Not supported |
F1020 |
Slot 1 |
Low speed |
· NSQM1GT4PFC · NSQM1GP4FBA |
F1030/F1040/F1050/F1060/F1070/F1080 |
Slots 1 and 2 |
Low speed |
· NSQM1GT4PFC · NSQM1GP4FBA |
F1090 |
Slots 1 to 3 |
High speed |
NS-NIM-TG6A |
Slots 2 to 4 |
Low speed |
· NSQM1GT4PFC · NSQM1GP4FBA |
NSQM1GT4PFC
The NSQM1GT4PFC interface module provides four 10/100/1000BASE-T Ethernet copper ports.
· When the firewall is operating correctly, the four ports operate as common data ports.
· When the firewall is powered off, the four ports are divided into two bypass port pairs with ports 0 and 1 in one pair and ports 2 and 3 in another pair. The two ports in a pair can act as the uplink and downlink interfaces for a Layer 2 link and form a bypass link. This enables traffic to be transmitted through the firewall even if the firewall is powered off and ensures service continuity.
Figure1-15 Front panel of the NSQM1GT4PFC interface module
(1) 10/100/1000BASE-T Ethernet copper ports |
(2) Captive screw |
(3) Ejector lever |
NSQM1GP4FBA
The NSQM1GP4FBA interface module provides four 1000BASE-X Ethernet fiber ports.
Figure1-16 Front panel of the NSQM1GP4FBA interface module
(1) 1000BASE-X Ethernet fiber ports |
(2) Captive screw |
(3) Ejector lever |
NS-NIM-TG6A
The NS-NIM-TG6A interface module provides six 10GBASE-R Ethernet fiber ports.
Figure1-17 Front panel of the NS-NIM-TG6A interface module
(1) 10GBASE-R Ethernet fiber ports |
(2) Captive screw |
(3) Ejector lever |
Network data encryption modules
The appearance of network data encryption modules varies by models. For more information, see H3C SecPath Firewall Network Data Encryption Module Guide.
Table1-2 describes the hardware and software compatibility with the network data encryption modules.
Table1-2 Hardware and software compatibility with the network data encryption modules
Network data encryption module |
Applicable firewalls |
Applicable slots |
Applicable software version |
NSQM1F1KGM0 |
F1003-C, F1003-S, F1003-M, F1005, F1010 |
N/A |
N/A |
F1020, F1030, F1050, F1060, F1070, F1080 |
Slot 1 |
R9333 and later |
|
F1090 |
Slots 1 and 3 |
R8601P24 and later |
|
NSQM1F1KGMB |
F1003-C, F1003-S, F1003-M, F1005, F1010 |
N/A |
N/A |
F1020 |
Slot 1 |
R9345 and later |
|
F1030, F1050, F1060, F1070, F1080 |
Slots 1 and 2 |
R9345 and later |
|
F1090 |
Slots 1 to 4 |
R8601P24 and later |
|
NSQM1F1KGMC |
F1003-C, F1003-S, F1003-M, F1005, F1010 |
N/A |
N/A |
F1020 |
Slot 1 |
R9345P14 and later |
|
F1030, F1050, F1060, F1070, F1080 |
Slots 1 and 2 |
R9345P14 and later |
|
F1090 |
Subslots 1 to 4 |
R8601P24 and later |
Drives
Table1-3 describes the compatibility between drives and F10X0 firewalls.
Table1-3 Drive compatibility with F10X0 firewalls
Drive |
F1003-C/F1003-S/F1003-M |
F1005/F1010 |
F1020/F1030/F1050/F1060 |
F1070/F1080 |
F1090 |
NS-SSD-480G-SATA-SFF |
No |
Yes |
Yes |
Yes |
Yes |
NS-HDD-500G-SATA-SFF |
No |
No |
Yes |
No |
Yes |
NS-HDD-1T-SATA-SFF |
No |
No |
Yes |
No |
Yes |
Power modules
The F1070/F1080/F1090 firewall came with power module slot PWR0 installed with a filler panel and power module slot PWR1 empty. It supports both AC and DC power modules. No power modules are provided with the firewall. Prepare power modules for the firewall yourself as required.
The F1070/F1080/F1090 firewall supports hot swapping of power modules and 1+1 power module redundancy. To install two power modules for the firewall, make sure they are the same model.
Table1-4 Power modules available for the firewall
Firewall model |
Available power modules |
F1003-C/F1003-S/F1003-M |
One built-in power module |
F1005/F1010 |
One built-in power module |
F1020/F1030/F1050/F1060 |
Two built-in power modules |
F1070/F1080 |
Two power module slots, supporting the following power modules: · PSR150-A1 · PSR150-D1 |
F1090 |
Two power module slots, supporting the following power modules: · PSR250-12A1 · PSR450-12AHD · PSR450-12D |
AC power modules
PSR150-A1
The PSR150-A1 power module with a product code of PSR150-A1-B provides a maximum output power of 150 W.
Figure1-18 PSR150-A1 power module
(1) Handle |
(2) Power receptacle |
PSR250-12A1
The PSR250-12A1 power module with a product code of PSR250-12A1 provides a maximum output power of 250 W.
Figure1-19 PSR250-12A1 power module
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power receptacle |
DC power modules
PSR150-D1
The PSR150-D1 power module with a product code of PSR150-D1-B provides a maximum output power of 150 W.
Figure1-20 PSR150-D1 power module
(1) Handle |
(2) Power receptacle |
PSR450-12D
The PSR450-12D power module with a product code of PSR450-12D provides a maximum output power of 450 W.
Figure1-21 PSR450-12D power module
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power receptacle |
High-voltage DC power modules
PSR450-12AHD
The PSR450-12AHD power module with a product code of PSR450-12AHD provides a maximum output power of 450 W.
Figure1-22 PSR450-12AHD power module
(1) Latch |
(2) Status LED |
(3) Handle |
(4) Power receptacle |
Dimensions and weights
The weight of the firewall includes the chassis and its removable components.
Chassis
Table1-5 Chassis dimensions and weights
Dimensions (H × W × D), excluding rubber feet and mounting brackets |
Weight |
|
F1003-C/F1003-S |
44 × 266 × 161 mm (1.73 × 10.47 × 6.34 in) |
1 kg (2.20 lb) |
F1003-M |
44 × 330 × 230 mm (1.73 × 12.99 × 9.06 in) |
1.5 kg (3.31 lb) |
F1005/F1010 |
44 × 440 × 230 mm (1.73 × 17.32 × 9.06 in) |
3 kg (6.61 lb) |
F1020 |
44.2 × 440 × 435 mm (1.74 × 17.32 × 17.13 in) |
6.75 kg (14.88 lb) |
F1030/F1050/F1060 |
44.2 × 440 × 435 mm (1.74 × 17.32 × 17.13 in) |
7.3 kg (16.09 lb) |
F1070/F1080 |
44.2 × 440 × 435 mm (1.74 × 17.32 × 17.13 in) |
8.5 kg (18.74 lb) |
F1090 |
44 × 440 × 435 mm (1.73 × 17.32 × 17.13 in) |
10 kg (22.05 lb) |
Interface modules
Table1-6 Interface module dimensions and weights
Interface module model |
Dimensions (H × W × D) |
Weight |
NSQM1GT4PFC |
19 × 150 × 172.9 mm (0.75 × 5.91 × 6.81 in) |
0.45 kg (0.99 lb) |
NSQM1GP4FBA |
19 × 150 × 172.9 mm (0.75 × 5.91 × 6.81 in) |
0.42 kg (0.93 lb) |
NS-NIM-TG6A |
19 × 150 × 172.9 mm (0.75 × 5.91 × 6.81 in) |
0.4 kg (0.88 lb) |
Network data encryption modules
Table1-7 Network data encryption module dimensions and weights
Network data encryption module model |
Dimensions (H × W × D) |
Weight |
NSQM1F1KGM0 |
40.1 × 150 × 172.9 mm (1.58 × 5.91 × 6.81 in) |
0.64 kg (1.41 lb) |
NSQM1F1KGMB |
19.8 × 150 × 172.9 mm (0.78 × 5.91 × 6.81 in) |
0.36 kg (0.79 lb) |
NSQM1F1KGMC |
19.8 × 150 × 172.9 mm (0.78 × 5.91 × 6.81 in) |
0.38 kg (0.84 lb) |
Drives
Table1-8 Drive dimensions and weights
Drive model |
Dimensions (H × W × D) |
Weight |
NS-SSD-480G-SATA-SFF |
19 × 75.7 × 118.4 mm (0.75 × 2.98 × 4.66 in) |
0.069 kg (0.15 lb) |
NS-HDD-500G-SATA-SFF |
19 × 75.7 × 118.4 mm (0.75 × 2.98 × 4.66 in) |
0.12 kg (0.26 lb) |
NS-HDD-1T-SATA-SFF |
19 × 75.7 × 118.4 mm (0.75 × 2.98 × 4.66 in) |
0.14 kg (0.31 lb) |
Storage media
Table1-9 Storage media specifications
Firewall model |
Memory |
F1003-C |
1GB DDR4 |
F1003-S/F1003-M |
2GB DDR4 |
F1005/F1010 |
2GB DDR3 |
F1020 |
2GB DDR3 |
F1030/F1050 |
4GB DDR3 |
F1060/F1070 |
8GB DDR3 |
F1080 |
16GB DDR3 |
F1090 |
16GB DDR4 |
Table1-10 Memory specifications of drives
Drive model |
Memory |
NS-SSD-480G-SATA-SFF |
480 GB |
NS-HDD-500G-SATA-SFF |
500 GB |
NS-HDD-1T-SATA-SFF |
1 TB |
Power consumption
The system power consumption includes the power consumptions of the chassis and the removable components.
Chassis
Table1-11 Chassis power consumption
Firewall model |
Power consumption |
F1003-C |
10.5 W |
F1003-S |
10.5 W |
F1003-M |
12 W |
F1005/F1010 |
32 W |
F1020/F1030/F1050/F1060 |
79 W |
F1070/F1080 |
116 W |
F1090 |
180 W |
Interface modules
Table1-12 Interface module power consumption
Interface module model |
Power consumption |
NSQM1GT4PFC |
11.5 W |
NSQM1GP4FBA |
10.4 W |
NS-NIM-TG6A |
11 W |
Network data encryption modules
Table1-13 Network data encryption module power consumption
Network data encryption module model |
Power consumption |
NSQM1F1KGM0 |
4.14 W |
NSQM1F1KGMB |
3.7 W |
NSQM1F1KGMC |
5.7 W |
Drives
Table1-14 Drive power consumption
Drive model |
Power consumption |
NS-SSD-480G-SATA-SFF |
3 W |
NS-HDD-500G-SATA-SFF |
4.9 W |
NS-HDD-1T-SATA-SFF |
5 W |
Power module specifications
Table1-15 Power specifications for the F1003-C/F1003-S/F1003-M firewall
Item |
Specification |
Rated input voltage |
12 VDC |
Maximum input current |
· F1003-C/F1003-S: 1.5 A · F1003-M: 2 A |
Maximum power |
24 W |
Table1-16 AC power module specifications
Model |
Rated input voltage range |
Maximum input current |
Maximum power |
PSR150-A1 |
100 VAC to 240 VAC @ 50 Hz or 60 Hz |
2 A |
150 W |
PSR250-12A1 |
100 VAC to 240 VAC @ 50 Hz or 60 Hz |
5 A |
250 W |
Table1-17 DC power module specifications
Model |
Rated input voltage range |
Maximum input current |
Maximum power |
PSR150-D1 |
–48 VDC to –60 VDC |
6 A |
150 W |
PSR450-12D |
–48 VDC to –60 VDC |
15 A |
450 W |
Table1-18 High-voltage DC power module specifications
Model |
Rated input voltage range |
Maximum input current |
Maximum power |
|
PSR450-12AHD |
AC input |
100 VAC to 240 VAC @ 50 Hz or 60 Hz |
7 A |
450 W |
High-voltage DC input |
240 VDC to 380 VDC |
3.5 A |
450 W |
Port specifications
Console port
Table1-19 Console port specifications
Item |
Specification |
Connector |
RJ-45 |
Standard compliant |
RS-232 |
Baud rate |
9600 bps (default) to 115200 bps |
Cable type |
Common asynchronous serial port cable |
Transmission distance |
≤ 15 m (49.21 ft) |
Services |
· Connection to an ASCII terminal · Connection to the serial port of a local PC running the terminal emulation program · CLI |
Micro USB console port
Table1-20 Micro USB console port specifications
Item |
Specification |
Connector |
Micro USB |
Standard compliant |
Micro USB |
Baud rate |
9600 bps (default) to 115200 bps |
Cable type |
USB console cable |
Transmission distance |
≤ 10 m (32.81 ft) |
Services |
· Connection to an ASCII terminal · Connection to the serial port of a local PC running the terminal emulation program · CLI |
GE copper port
Table1-21 GE copper port specifications
Item |
Specification |
Connector |
RJ-45 |
Standard compliance |
802.3, 802.3u, and 802.3ab |
Interface type |
MDI/MDI-X autosensing |
Cable type |
Category 5 or above twisted pair cable |
Transmission distance |
100 m (328.08 ft) |
Interface speed and duplex mode |
10 Mbps, half/full-duplex 100 Mbps, half/full-duplex 1000 Mbps, full-duplex |
|
NOTE: The media dependent interface (MDI) standard is typically used on the Ethernet port of network adapters. The media dependent interface crossover (MDI-X) standard is typically used on hubs or LAN switches. |
GE fiber port
Table1-22 GE fiber port specifications
Item |
Specification |
Connector type |
LC |
Transceiver module type |
SFP |
Standard compliance |
1000BASE-X |
Interface speed |
1000 Mbps |
Duplex mode |
Full duplex |
Table1-23 1000BASE-X SFP transceiver module specifications
Transceiver module |
Central wavelength (nm) |
Connector |
Cable specifications (µm) |
Max transmission distance |
SFP-GE-SX-MM850-A |
850 |
LC |
50/125, multi-mode optical fiber (MMF) |
0.55 km (1804.46 ft) |
SFP-GE-LX-SM1310-A |
1310 |
LC |
9/125, single-mode optical fiber (SMF) |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310 |
1310 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 |
1550 |
LC |
9/125, SMF |
80 km (49.71 miles) |
SFP-GE-LH100-SM1550 |
1550 |
LC |
9/125, SMF |
100 km (62.14 miles) |
10GE fiber port
The F1070/F1080 firewall provides two 10GBASE-R Ethernet fiber ports and the F1090 provides eight 10GBASE-R Ethernet fiber ports.
Table1-24 10GE fiber port specifications
Item |
Specification |
Connector type |
LC |
Transceiver module type |
SFP+ |
Standard compliance |
10GBASE-R |
Interface speed |
LAN PHY: 10.3125 Gbps/1000 Mbps |
Table1-25 10 Gbps SFP+ transceiver module specifications
Transceiver module |
Central wavelength (nm) |
Connector |
Cable specifications (µm) |
Max transmission distance |
SFP-XG-SX-MM850-A |
850 |
LC |
50/125, MMF |
300 m (984.25 ft) |
82 m (269.03 ft) |
||||
66 m (216.54 ft) |
||||
62.5/125, MMF |
33 m (108.27 ft) |
|||
26 m (85.30 ft) |
||||
SFP-XG-LX220-MM1310 |
1310 |
LC |
62.5/125, MMF |
220 m (721.78 ft) |
50/125, MMF |
220 m (721.78 ft) |
|||
100 m (328.08 ft) |
||||
SFP-XG-LX-SM1310 |
1310 |
LC |
9/125, SMF |
10 km (6.21 miles) |
SFP-XG-LH40-SM1550 |
1550 |
LC |
9/125, SMF |
40 km (24.86 miles) |
|
NOTE: The 10GE fiber ports on the F1090 support only SFP-XG-LH40-SM1550 transceiver modules. |