Configuring the OAP module

H3C Open Application Architecture provides an open interface for third-party vendors to develop and integrate value-added applications into H3C products. These applications can apply to one of the following forms:

·     A standalone network device.

·     A card that can be installed in a network device (Open Application Platform module, or OAP module).

OAP modules have their own operating systems. You can log in to the operating system of an OAP module to install features. For example, you can install security features and voice features on the OAP module operating system to provide security and voice services for users.

OAP modules exchange data, status information, and control information with hosting devices through internal interfaces.

Table 1 Module type

OAP module

Module type

Number of internal interfaces

LSU1FWCEA0

Firewall card

Four 10G Ethernet interfaces

LSU3FWCEA0

Four 10G Ethernet interfaces

LSQ1FWBSC0

Two 10G Ethernet interfaces. Only the first one is available.

LSQ2FWBSC0

Two 10G Ethernet interfaces. Only the first one is available.

LSUM1FWCEAB0

Four 10G Ethernet interfaces

LSU1IPSBEA0

IPS card

Four 10G Ethernet interfaces

LSQ1IPSSC0

One 10G Ethernet interface

LSQ1SSLSC0

SSL VPN card

One 10G Ethernet interface

LSQ1ACGASC0

ACG card

One 10G Ethernet interface

LSQ1NSMSC0

NetStream card

Two 10G Ethernet interfaces. Only the first one is available.

LSU1NSCEA0

Four 10G Ethernet interfaces

LSU3WCMD0

High performance access controller module

Two 10G Ethernet interfaces

LSU1WCME0

Four 10G Ethernet interfaces

LSQ1WCMD0

Two 10G Ethernet interfaces

LSU1ADECEA0

Application delivery engine module

Four 10G Ethernet interfaces

LSQ1LBSC0

LB card

Two 10G Ethernet interfaces

 

 

IMPORTANT

IMPORTANT:

An LSQ OAP module can only be installed on an S7506E-X.

 

IMPORTANT

IMPORTANT:

·     For the traffic received from the interface module to be redirected to the OAP module correctly, do not install any of the following interface modules on an S7502E that has an LSQ OAP module installed:

¡     LSQM1TGS12EC0.

¡     LSQM2GP44TSSC0.

¡     LSQM2GP24TSSC0.

¡     LSQM2GT24PTSSC0.

¡     LSQM2GT24TSSC0.

¡     LSQM2GT48SC0.

¡     LSQM4GV48SC0.

¡     SA interface modules.

·     An LSU1WCME0 cannot be installed on an S7502E.

 

Internal interfaces for OAP modules

An OAP module integrates a front card and a rear card. The front card provides value-added security services, such as firewall, intrusion prevention, and application control. The rear card is responsible for data exchange between the front card and the switch. The rear card communicates with the front card through the internal interface, as shown in the following figure.

Figure 1 Diagram for the internal interface

 

IMPORTANT

IMPORTANT:

·     On an LSQ OAP module, an internal interface cannot be set to operate in Layer 3 mode. For more information about Ethernet interface operating modes, see Interface Configuration Guide.

·     BFD is not available on internal interfaces of an LSQ OAP module. For more information about BFD, see High Availability Configuration Guide.

 

Logging in to an OAP module

Logging in through the console port on the OAP module

1.     Connect one end of the console cable to the serial port of the configuration terminal (for example, a PC).

2.     Connect the other end of the console cable to the console port of the OAP module.

3.     Start the PC and run a terminal emulation program, such as HyperTerminal.

4.     Select the COM connection mode and set the terminal parameters as follows:

¡     Bits per second9600.

¡     Data bits8.

¡     Parity check mode—None.

¡     Stop bits1.

¡     Flow control—None.

5.     Follow the OAP module user guide to log in to the operating system of the OAP module through the terminal emulation program.

Logging in through the management Ethernet port on the OAP module by using SSH

1.     Connect the management Ethernet port of the OAP module to the network by using a network cable.

2.     Log in to the OAP module through the console port and enable the SSH server function on the OAP module.

3.     Assign an IP address to the management Ethernet port of the OAP module. Make sure the management Ethernet port and the SSH client (an H3C device or a PC with SSH client software) can reach each other.

4.     From the SSH client, establish an SSH connection to the IP address of the management Ethernet port on the OAP module.

After the SSH connection is successfully established, you are logged in to the operating system of the OAP module.

Logging in through the internal Ethernet interface on the OAP module by using SSH

When installed in the expansion slot of a device, an OAP module exchanges information with the device through two internal interfaces: one console port and one fast Ethernet interface. The fast Ethernet interface is used for this login method.

To log in to the operating system of an OAP module through the internal Ethernet interface:

1.     Connect the SSH client (for example, a PC) to the Ethernet port of the device by using a network cable.

2.     Log in to the OAP module through the console port and enable the SSH server function on the OAP module.

3.     Assign an IP address to the internal Ethernet interface on the OAP module. Make sure the PC and the fast Ethernet interface on the OAP module can reach each other.

4.     From the SSH client, establish an SSH connection to the IP address of the fast Ethernet interface.

After the SSH connection is successfully established, you are logged in to the operating system of the OAP module.

Redirecting to the OAP module from the CLI of the device

From the CLI of the device, you can redirect to the CLI of the OAP module. To return to the CLI of the device, press Ctrl+K.

Perform the following task in user view:

 

Task

Command

Remarks

Redirect to the CLI of the OAP module from the device.

·     In standalone mode:
oap connect slot slot-number

·     In IRF mode:
oap connect chassis chassis-number slot slot-number

The oap connect command is available only on the default MDC.

The oap connect command is not available on the following OAP modules:

·     LSQ OAP modules.

·     LSU1IPSBEA0.

 

Resetting OAP modules

CAUTION

CAUTION:

Resetting an OAP module might cause a service outage.

 

IMPORTANT

IMPORTANT:

To avoid service data loss, close the operating system of an OAP module before resetting the module.

 

You can reset an OAP module to restore it to normal operation in the following situations:

·     The OAP module fails.

·     The OAP module is not operating correctly. For example, the OAP module does not respond to your operation.

Pressing the reset button of the OAP module has the same effect. The device can still identify and control the OAP module after the module starts up again.

Perform the following task in user view:

 

Task

Command

Remarks

Reset the OAP module.

·     In standalone mode:
oap reboot slot slot-number [ system system-name ]

·     In IRF mode:
oap reboot chassis chassis-number slot slot-number

The oap reboot command is not available on the following OAP modules:

·     LSQ OAP modules.

·     LSU1IPSBEA0.

·     LSU1WCME0.

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网