• 产品与解决方案
  • 行业解决方案
  • 服务
  • 支持
  • 合作伙伴
  • 关于我们

H3C MSR系列路由器 接口模块手册(V5)(1.17)

03-附录B 适配关系

本章节下载: 03-附录B 适配关系  (186.53 KB)

03-附录B 适配关系


附录B  选配参考

在使用H3C MSR系列路由器时,请参考本章内容配置接口模块。其中“√”表示该型号路由器可支持此功能接口模块,“×”表示该型号路由器不支持此功能接口模块。

B.1  SIC/DSIC模块选配参考

说明

·         MSR 50(安装MPU-G2主控板时)、MSR800、MSR 900、MSR900-E和MSR 930路由器不支持安装SIC/DSIC接口模块。

·         PoE接口模块需要与PoE款型设备配合使用,才可以提供PoE供电功能,否则仅能作为二层转发接口模块使用。

 

表B-1 SIC/DSIC模块选配参考 Part1

类型

20-1X

20-20/ 20-21

20-40

30-10

30-11

30-11E/30-11F

30-16

30-20/30-40/ 30-60

50-40/ 50-60 + MPUF

SIC-4FSW

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-4FSWP

×

×

√

(Slot 2 and 4 support only)

×

×

×

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

DSIC-9FSW

√

×

√

(Slot 2 and 4 support only)

×

×

×

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

DSIC-9FSWP

√

√

√

(Slot 2 and 4 support only)

×

×

×

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-1FEF

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-1FEA

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-1GEC-V2

×

×

×

×

×

×

×

×

×

SIC-1GEC-H3

√

×

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-E1-F

√

√

√

√

√

√

(Slot 1 support only)

√

√

√

SIC-T1-F

√

√

√

√

√

√

(Slot 1 support only)

√

√

√

SIC-2E1-F

√

√

√

√

√

√

√

√

√

SIC-EPRI

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-1EPRI

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-TPRI

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-8AS

√

√

√

√

√

√

√

√

√

SIC-16AS

√

√

√

√

√

√

√

√

√

SIC-1SAE

√

√

√

√

√

(Slot 1 support only)

√

√

√

√

SIC-1AM

√

√

√

√

√

(Slot 1 support only)

√

√

√

√

SIC-2AM

×

×

√

×

×

×

√

√

√

SIC-1ADSL

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

SIC-1ADSL-I

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-1BS

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-2BS

×

×

√

×

×

×

√

(Slot 1 and 3 support only)

√

√

SIC-1BU

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-2BU

×

×

√

×

×

×

√

(Slot 1 and 3 support only)

√

√

SIC-1FXS

√

√

√

√

√

√

√

√

√

SIC-2FXS

√

√

√

√

√

√

√

√

√

SIC-1FXO

√

√

√

√

√

√

√

√

√

SIC-2FXO

√

√

√

√

√

√

√

√

√

SIC-2 FXS1FXO

√

√

√

√

√

√

√

√

√

DSIC-4FXS1FXO

√

√

√

√

×

√

√

√

√

SIC-1BSV

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-2BSV

√

√

√

√

√

(Slot 1 support only)

√

(Slot 1 support only)

√

√

√

SIC-1VE1

√

×

√

√

(Slot 1 support only)

×

×

√

√

√

SIC-1VT1

√

×

√

√

(Slot 1 support only)

×

×

√

√

√

SIC-3G-CDMA

√

√

√

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

√

√

SIC-3G-TD

√

√

√

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

√

√

SIC-3G-GSM

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-3G-HSPA

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-WLAN-b/g/n

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

SIC-EPON

√

√

√

(Slot 2 and 4 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

(Slot 2 support only)

√

√

(Slot 2 and 4 support only)

√

(Slot 2 and 4 support only)

 

表B-2 SIC/DSIC模块选配参考 Part2

类型

26-00-10

26-00-17

SIC-1FEF

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-1GEC-V2

√

(Slot 2 support only)

√

(Slot 2 support only)

SIC-1GEC-H3

×

×

SIC-1FEA

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-4FSW

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-4FSWP

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

DSIC-9FSW

×

×

DSIC-9FSWP

×

×

SIC-E1-F

√

√

SIC-2E1-F

√

√

SIC-T1-F

√

√

SIC-EPRI

√

√

SIC-1EPRI

√

√

SIC-1SAE

√

√

SIC-2SAE

√

√

SIC-4SAE

√

√

SIC-8AS

√

√

SIC-16AS

√

√

SIC-1AM

√

√

SIC-1ADSL

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-1ADSL-I

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-1BS

√

√

SIC-2BS

×

×

SIC-1FXS

√

√

SIC-2FXS

√

√

SIC-1FXO

√

√

SIC-2FXO

√

√

SIC-2FXS1FXO

√

√

DSIC-4FXS1FXO

×

×

SIC-1BSV

√

√

SIC-2BSV

√

√

SIC-1VE1

×

×

SIC-1VT1

×

×

SIC-3G-TD

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-3G-HSPA

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-3G-CDMA

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-4G-LTE-M

√

(Slot 2 and 3 support only)

√

(Slot 2 and 4 support only)

SIC-CNDE

√

(Slot 2 and 3 support only)

 (整机最大支持数为1)

√

(Slot 2 and 4 support only)

 (整机最大支持数为1)

 

B.2  MIM/XMIM/DMIM模块选配参考

说明

·         仅MSR 30路由器支持安装MIM/XMIM/DMIM接口模块。

·         PoE接口模块需要与PoE款型设备配合使用,才可以提供PoE供电功能,否则仅能作为二层转发接口模块使用。

 

表B-3 MIM/XMIM模块选配参考

类型

30-10/30-11

30-11E/30-11F/30-16

30-20

30-40/ 30-60

MIM-16FSW

√

√

√

√

MIM-16FSWP

√

√

√

√

XMIM-16FSW

√

×

×

×

XMIM-24FSW

√

×

×

×

DMIM-24FSW

×

×

×

√

DMIM-24FSWP

×

×

×

√

DMIM-48FSW

×

×

×

√

MIM-1FE

√

√

√

√

MIM-2FE

√

√

√

√

MIM-4FE

√

√

√

√

MIM-1GBE

√

√

√

√

MIM-2GBE

√

√

√

√

MIM-1GEF

√

√

√

√

MIM-2GEF

√

√

√

√

MIM-1ATM-OC3

√

√

√

√

MIM-1AE3

√

√

√

√

MIM-1AT3

√

√

√

√

MIM-IMA-4E1(75)

√

√

√

√

MIM-IMA-8E1(75)

√

√

√

√

MIM-IMA-4T1

√

√

√

√

MIM-IMA-8T1

√

√

√

√

MIM-1POS

√

√

√

√

MIM-1CPOS

√

√

√

√

MIM-1E1

√

√

√

√

MIM-2E1

√

√

√

√

MIM-4E1

√

√

√

√

MIM-1E1-F

√

√

√

√

MIM-2E1-F

√

√

√

√

MIM-4E1-F

√

√

√

√

MIM-8E1(75)

√

√

√

√

MIM-8E1(75)-F

√

√

√

√

MIM-1T1

√

√

√

√

MIM-2T1

√

√

√

√

MIM-4T1

√

√

√

√

MIM-1T1-F

√

√

√

√

MIM-2T1-F

√

√

√

√

MIM-4T1-F

√

√

√

√

MIM-8T1

√

√

√

√

MIM-8T1-F

√

√

√

√

MIM-1CE3

√

√

√

√

MIM-1CT3

√

√

√

√

MIM-1SHL-4W

√

√

√

√

MIM-1G.SHDSL

√

√

√

√

MIM-4BSE

√

√

√

√

MIM-2SAE

√

√

√

√

MIM-4SAE

√

√

√

√

MIM-8SAE

√

√

√

√

MIM-8ASE

√

√

√

√

MIM-16ASE

√

√

√

√

MIM-6FCM

√

√

√

√

MIM-2FXS

√

√

√

√

MIM-2FXO

√

√

√

√

MIM-4FXS

√

√

√

√

MIM-4FXO

√

√

√

√

MIM-8FXS8FXO

√

√

√

√

MIM-16FXS

√

√

√

√

MIM-2E&M

√

√

√

√

MIM-4E&M

√

√

√

√

MIM-2BSV

√

√

√

√

MIM-4BSV

√

√

√

√

MIM-1VE1

√

√

√

√

MIM-1VT1

√

√

√

√

MIM-2VE1

√

√

√

√

MIM-2VT1

√

√

√

√

MIM-HNDE

√

√

√

√

 

B.3  FIC/DFIC模块选配参考

说明

·         仅MSR 50路由器支持安装FIC/DFIC接口模块。

·         PoE接口模块需要与PoE款型设备配合使用,才可以提供PoE供电功能,否则仅能作为二层转发接口模块使用。

 

表B-4 FIC/DFIC模块选配参考

类型

50-40/ 50-60 MPUF

50-40/ 50-60 MPU-G2

FIC-16FSW

√

√

FIC-16FSWP

√

×

DFIC-24FSW

√

√

DFIC-24FSWP

√

×

FIC-1FE

√

√

FIC-2FE

√

√

FIC-4FE

√

√

FIC-1GBE

√

√

FIC-2GBE

√

√

FIC-1GEF

√

√

FIC-2GEF

√

√

FIC-IMA-4E1(75)

√

√

FIC-IMA-8E1(75)

√

√

FIC-1AE3

√

√

FIC-1AT3

√

√

FIC-IMA-4T1

√

√

FIC-IMA-8T1

√

√

FIC-1ATM-OC3MM

√

√

FIC-1POS

√

√

FIC-1CPOS

√

√

FIC-1E1

√

√

FIC-2E1

√

√

FIC-4E1

√

√

FIC-1E1-F

√

√

FIC-2E1-F

√

√

FIC-4E1-F

√

√

FIC-8E1(75)

√

√

FIC-8E1-F(75)

√

√

FIC-1T1

√

√

FIC-2T1

√

√

FIC-4T1

√

√

FIC-8T1

√

√

FIC-1T1-F

√

√

FIC-2T1-F

√

√

FIC-4T1-F

√

√

FIC-8T1-F

√

√

FIC-1CE3

√

√

FIC-1CT3

√

√

FIC-1SHL-4W

√

√

FIC-1G.SHDSL

√

√

FIC-4BSE

√

√

FIC-2SAE

√

√

FIC-4SAE

√

√

FIC-8SAE

√

√

FIC-8ASE

√

√

FIC-16ASE

√

√

FIC-6FCM

√

√

FIC-1E1POS

√

√

FIC-2FXS

√

√

FIC-2FXO

√

√

FIC-4FXS

√

√

FIC-4FXO

√

√

FIC-24FXS

√

√

DFIC-24FXO24FXS

√

√

FIC-2E&M

√

√

FIC-4E&M

√

√

FIC-2BSV

√

√

FIC-4BSV

√

√

FIC-1VE1

√

√

FIC-1VT1

√

√

FIC-2VE1

√

√

FIC-2VT1

√

√

FIC-HNDE

√

√

 

B.4  ESM/VPM/VCPM模块选配参考

表B-5 ESM/VPM/VCPM模块选配参考

类型

900

20-10/20-11/20-13

20-12

20-20/ 20-21

20-40

30-10

30-11E/30-11F

30-16

30-20/30-40/ 30-60

50-40/ 50-60 +  MPUF +  MSCA

50-40/ 50-60 + MPU-G2 + MSCB

ESM-ANDE

×

×

×

√

√

√

√

√

√

√

√

ESM-SNDE

×

×

×

√

√

√

√

√

√

√

√

VCPM

×

×

×

×

√

×

×

√

√

√

√

VPM32

×

×

√

×

√

√

×

√

√

√

×

VPM24

×

×

√

×

√

√

×

√

√

√

×

VPM16

×

×

√

×

√

√

×

√

√

√

×

VPM8

×

×

√

×

√

√

×

√

√

√

×

 

不同款型规格的资料略有差异, 详细信息请向具体销售和400咨询。H3C保留在没有任何通知或提示的情况下对资料内容进行修改的权利!

新华三官网