H3C S5130S-EI-G-V2系列交换机是新华三技术有限公司最新推出的自主可控以太网交换机产品,支持多种认证方式和加密技术,主机均固化万兆光口。
H3C S5130S-EI-G-V2系列以太网交换机目前包含如下型号:
S5130S-48UN6X-EI-G-V2:48个10/100/1G/2.5G BASE-T PoE++电口,6个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-24UN8X-EI-G-V2:24个10/100/1G/2.5G BASE-T PoE++电口,8个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-48S6X-EI-G-V2:48个100/1000Base-X SFP端口,6个1G/2.5G/10GBase-X SFP Plus端口,2个电源模块槽位。
S5130S-48T6X-EI-G-V2:48个10/100/1000BASE-T电口,6个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-48P6X-EI-G-V2:48个10/100/1000BASE-T PoE+电口,6个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-28S8T8X-EI-G-V2:28个1000BASE-X SFP端口(含8个GE Combo口),8个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-28T8X-EI-G-V2:28个10/100/1000BASE-T端口,8个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-28P8X-EI-G-V2:28个10/100/1000BASE-T PoE+电口,8个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-48U6X-EI-G-V2:48个10/100/1000BASE-T PoE++端口,6个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-28U4S8X-EI-G-V2:28个10/100/1000BASE-T PoE++端口(含4个SFP Combo口),8个1G/2.5G/10G BASE-X SFP Plus端口,2个电源模块槽位。
S5130S-24N8XC-EI-G-V2:24个10/100/1G/2.5G BASE-T电口,8个1G/2.5G/10G BASE-X SFP Plus端口,1个Slot插槽,2个电源模块槽位。
S5130S-24UN8XC-EI-G-V2:24个10/100/1G/2.5G BASE-T PoE++电口,8个1G/2.5G/10G BASE-X SFP Plus端口,1个Slot插槽,2个电源模块槽位。
S5130S-48N4XC-EI-G-V2:48个10/100/1G/2.5G BASE-T电口,4个1G/2.5G/10G BASE-X SFP Plus端口,1个Slot插槽,2个电源模块槽位。
S5130S-48UN4XC-EI-G-V2:48个10/100/1G/2.5G BASE-T PoE++电口,4个1G/2.5G/10G BASE-X SFP Plus端口,1个Slot插槽,2个电源模块槽位。
随着网络规模的增加,网络边缘需要使用大量的接入设备,这使对这些设备的管理工作非常繁琐。SmartMC的主要目的就是解决大量分散的网络设备的集中管理问题。旨在解决小企业以交换机为主的运维任务。SmartMC以设备内置及图形化操作的方式,实现对网络的统一运维及管理
SmartMC四大业务板块简化中小园区运维及管理:
智能管理:
主要包括设备角色选定、FTP服务器配置、全局配置及网管口配置等
智能运维:
主要包括组管理、设备或组升级备份、监控及设备故障替换等
可视化:
主要包括组网拓扑可视及管理、设备列表展示等
智能业务:
主要包括用户管理等:在创建了网络接入类用户并成功激活后,这些用户可以通过一键布防的端口来访问SmartMC网络内部。
H3C S5130S-EI-G-V2系列交换机可作为SmartMC的被管理设备,作为被管理设备连接到SmartMC网络,实现纵向虚拟化统一管理。
H3C S5130S-EI-G-V2系列交换机支持Telemetry技术,可通过GRPC协议将交换机的实时资源信息与告警信息上送至运维平台,运维平台针对实时数据进行分析,可实现网络质量回溯,故障排查,风险预警,架构优化等功能,精确保障用户体验。
H3C S5130S-EI-G-V2系列交换机实现基于硬件的IPv4/IPv6双栈平台,支持多种隧道技术,丰富的IPv4和IPv6三层路由协议、组播技术以及策略路由机制,为用户提供完善的IPv4/IPv6解决方案。
H3C S5130S-EI-G-V2系列交换机支持横向虚拟化技术,就是把多台物理设备互相连接起来,使其虚拟为一台逻辑设备,也就是说,用户可以将这多台设备看成一台单一设备进行管理和使用。虚拟化可以为用户带来以下好处:
简化管理 虚拟化架构形成之后,可以连接到任何一台设备的任何一个端口就能登录统一的逻辑设备,通过对单台设备的配置达到管理整个智能弹性系统以及系统内所有成员设备的效果,而不用物理连接到每台成员设备上分别对它们进行配置和管理。
简化业务 虚拟化形成的逻辑设备中运行的各种控制协议也是作为单一设备统一运行的,例如路由协议会作为单一设备统一计算,而随着跨设备链路聚合技术的应用,可以替代原有的生成树协议,这样就可以省去了设备间大量协议报文的交互,简化了网络运行,缩短了网络动荡时的收敛时间。
弹性扩展 可以按照用户需求实现弹性扩展,保证用户投资。并且新增的设备加入或离开虚拟化架构时可以实现“热插拔”,不影响其他设备的正常运行。
高可靠 虚拟化的高可靠性体现在链路,设备和协议三个方面。成员设备之间物理端口支持聚合功能,虚拟化系统和上、下层设备之间的物理连接也支持聚合功能,这样通过多链路备份提高了链路的可靠性;虚拟化系统由多台成员设备组成,一旦Master设备故障,系统会迅速自动选举新的Master,以保证通过系统的业务不中断,从而实现了设备级的1:N备份;虚拟化系统会有实时的协议热备份功能负责将协议的配置信息备份到其他所有成员设备,从而实现1:N的协议可靠性。
高性能 对于高端交换机来说,性能和端口密度的提升会受到硬件结构的限制。而虚拟化系统的性能和端口密度是虚拟化内部所有设备性能和端口数量的总和。因此,虚拟化技术能够轻易的将设备的交换能力、用户端口的密度扩大数倍,从而大幅度提高了设备的性能。
H3C S5130S-EI-G-V2系列交换机支持EAD(终端准入控制)功能,配合后台系统可以将终端防病毒、补丁修复等终端安全措施与网络接入控制、访问权限控制等网络安全措施整合为一个联动的安全体系,通过对网络接入终端的检查、隔离、修复、管理和监控,使整个网络变被动防御为主动防御、变单点防御为全面防御、变分散管理为集中策略管理,提升了网络对病毒、蠕虫等新兴安全威胁的整体防御能力。
H3C S5130S-EI-G-V2系列交换机支持集中式MAC地址认证、802.1x认证、PORTAL认证,支持用户帐号、IP、MAC、VLAN、端口等用户标识元素的动态或静态绑定,同时实现用户策略(VLAN、QoS、ACL)的动态下发;支持配合H3C公司的iMC系统对在线用户进行实时的管理,及时的诊断和瓦解网络非法行为。
H3C S5130S-EI-G-V2系列交换机提供增强的ACL控制逻辑,支持超大容量的入端口和出端口ACL,并且支持基于VLAN的ACL下发,在简化用户配置过程的同时,避免了ACL资源的浪费。
MACsec(Media Access Control Security,MAC安全)定义了基于IEEE 802局域网络的数据安全通信的方法。MACsec可为用户提供安全的MAC层数据发送和接收服务,包括用户数据加密、数据帧完整性检查及数据源真实性校验。
MACsec通常与802.1X认证框架配合使用,工作在802.1X认证过程成功之后,通过识别出已认证设备发送的报文,并使用MKA(MACsec Key Agreement,MACsec密钥协商)协议协商生成的密钥对已认证的用户数据进行加密和完整性检查,避免端口处理未认证设备的报文或者未认证设备篡改的报文。
S5130S-EI-G-V2系列交换机具备设备级和链路级的多重可靠性保护。
S5130S-EI-G-V2系列交换机,支持可插拔电源模块冗余可靠性设计,此外整机还支持电源和风扇的故障检测及告警,可以根据温度的变化自动调节风扇的转速,这些设计使设备具备了更高的可靠性。
除了设备级可靠性以外,该产品还支持丰富的链路级可靠性技术,包括LACP/STP/RSTP/MSTP/Smart Link/RRPP快速环网保护机制等保护协议,支持智能弹性架构,支持1:N冗余备份,支持环形堆叠,支持跨设备的链路聚合,极大提高网络可靠性,当网络上承载多业务、大流量的时候也不影响网络的收敛时间,保证业务的正常开展。
S5130S-EI-G-V2系列交换机支持快速检测链路的通断,并支持端口下的环路检测功能,防止端口下因私接Hub等设备形成的环路而导致网络故障的现象。
S5130S-EI-G-V2系列采用专业的内置防雷技术,支持10KV防雷能力,即使在比较恶劣的工作环境中也能极大的降低雷击对设备的损坏率。
H3C S5130S-EI-G-V2系列交换机支持支持L2(Layer 2)~L4(Layer 4)包过滤功能,提供基于源MAC地址、目的MAC地址、源IP地址、目的IP地址、TCP/UDP端口号、协议类型、VLAN的流分类。提供灵活的对列调度算法,可以同时基于端口和队列进行设置。支持CAR(Committed Access Rate)功能。支持出、入两个方向的端口镜像,用于对指定端口上的报文进行监控,将端口上的数据包复制到监控端口,以进行网络检测和故障排除。同时H3C S5130S-EI-G-V2系列交换机还支持sFlow功能,对网络上的数据包进行采样,在千兆/万兆高速的网络上精确地监控网络流量,用于对网络流量进行统计分析和控制。
H3C S5130S-EI-G-V2系列交换机可支持PoE++(802.3bt)/PoE+(802.3at)/PoE(802.3af)功能,单端口最高可提供100W供电,能够为AP、摄像头等受电设备(PD)进行远程供电。此外H3C S5130S-EI-G-V2还将AI能力融入到PoE技术中,使得PoE交换机可以支持:
Fast PoE:PoE交换机上电后,可以实现秒级为受电设备供电,无需等待交换机启动完成
Perpetual PoE:交换机使用命令进行热重启时,保证受电设备的供电不会发生中断,维持受电设备的正常运行
H3C S5130S-EI-G-V2系列交换机可支持网络切片技术,支持在一个物理网络上切分出多个独立的虚拟网络,为不同业务按需分配资源并提供差异化的队列调度能力,满足各种业务的不同需求,又不需要影响已有的网络。在部署了网络切片功能的网络中,网络切片通道通过网络切片实例ID标识并关联网络切片实例。每个接口上可以创建多个网络切片通道,并为每个网络切片通道分配独立的调度队列,不同的网络切片通道的调度队列之间互不影响。
H3C S5130S-EI-G-V2系列交换机支持丰富的管理接口,例如Console口、带外网管口,ID指示灯,支持SNMPv1/v2/v3(Simple Network Management Protocol),iMC智能管理中心。支持CLI命令行,Web网管,TELNET,支持复位按钮和清配置按钮,使设备管理更方便,并且支持SSH2.0等加密方式,使得管理更加安全。
H3C S5130S-EI-G-V2系列交换机可以对网络流量进行分析以采取相应管理维护措施,使原本不可见的网络业务应用流量变得一目了然,可以为用户提供多种网流分析报表,帮助用户及时优化网络结构,调整资源部署。
H3C S5130S-EI-G-V2系列交换机支持2G内存,允许存储更多的地址表容量和访问控制列表,确保在不同应用负载和网络条件下都能稳定、高效地工作。
H3C S5130S-EI-G-V2系列交换机支持接入终端设备自动扫描识别,包括上线终端的MAC地址、厂商、类型、IP和操作系统等信息,支持接入终端可视化。内置网管软件,支持一键替换设备、批量下发配置、资源监控、支持纵向虚拟化统一管理。
型号 | 交换容量 | 包转发率 | 业务端口描述 | 外形尺寸(宽×深×高)(单位:mm) | 管理用以太网口 | USB口 | 串行CONSOLE口 |
S5130S-48UN6X-EI-G-V2 | 1.36Tbps/13.6Tbps | 327Mpps/770Mpps | 48个10/100/1G/2.5G BASE-T PoE++电口,6个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | 1 | 1 | 1个RJ45口,1个Type-C口 |
S5130S-24UN8X-EI-G-V2 | 1.36Tbps/13.6Tbps | 291Mpps/770Mpps | 24个10/100/1G/2.5G BASE-T PoE++电口,8个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | |||
S5130S-48S6X-EI-G-V2 | 1.36Tbps/13.6Tbps | 462Mpps/770Mpps | 48个100/1000Base-X SFP端口,6个1G/2.5G/10GBase-X SFP Plus端口 | 440×360×44 | |||
S5130S-48T6X-EI-G-V2 | 1.36Tbps/13.6Tbps | 327Mpps/770Mpps | 48个10/100/1000BASE-T电口,6个1G/2.5G/10G BASE-X SFP Plus端口 | 440×360×44 | |||
S5130S-48P6X-EI-G-V2 | 1.36Tbps/13.6Tbps | 327Mpps/770Mpps | 48个10/100/1000BASE-T PoE+电口,6个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | |||
S5130S-28S8T8X-EI-G-V2 | 1.36Tbps/13.6Tbps | 462Mpps/770Mpps | 28个1000BASE-X SFP端口(含8个GE Combo口),8个1G/2.5G/10G BASE-X SFP Plus端口 | 440×360×44 | |||
S5130S-28T8X-EI-G-V2 | 1.36Tbps/13.6Tbps | 291Mpps/770Mpps | 28个10/100/1000BASE-T端口,8个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | |||
S5130S-28P8X-EI-G-V2 | 1.36Tbps/13.6Tbps | 291Mpps/770Mpps | 28个10/100/1000BASE-T PoE+电口,8个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | |||
S5130S-48U6X-EI-G-V2 | 1.36Tbps/13.6Tbps | 327Mpps/770Mpps | 48个10/100/1000BASE-T PoE++端口,6个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | |||
S5130S-28U4S8X-EI-G-V2 | 1.36Tbps/13.6Tbps | 291Mpps/770Mpps | 28个10/100/1000BASE-T PoE++端口(含4个SFP Combo口),8个1G/2.5G/10G BASE-X SFP Plus端口 | 440×400×44 | |||
S5130S-24N8XC-EI-G-V2 | 1.36Tbps/13.6Tbps | 291Mpps/770Mpps | 24个10/100/1G/2.5G BASE-T电口,8个1G/2.5G/10G BASE-X SFP Plus端口,1个拓展插槽 | 440×360×44 | |||
S5130S-24UN8XC-EI-G-V2 | 1.36Tbps/13.6Tbps | 291Mpps/770Mpps | 24个10/100/1G/2.5G BASE-T PoE++电口,8个1G/2.5G/10G BASE-X SFP Plus端口,1个拓展插槽 | 440×400×44 | |||
S5130S-48N4XC-EI-G-V2 | 1.36Tbps/13.6Tbps | 327Mpps/770Mpps | 48个10/100/1G/2.5G BASE-T电口,4个1G/2.5G/10G BASE-X SFP Plus端口,1个拓展插槽 | 440×360×44 | |||
S5130S-48UN4XC-EI-G-V2 | 1.36Tbps/13.6Tbps | 327Mpps/770Mpps | 48个10/100/1G/2.5G BASE-T PoE++电口,4个1G/2.5G/10G BASE-X SFP Plus端口,1个拓展插槽 | 440×400×44 |
型号 | 功耗(静态) | 功耗(满负荷时) | 重量 | 工作环境温度 | 工作环境相对湿度(非凝露) |
S5130S-48UN6X-EI-G-V2 | 单AC:51W 双AC:59W 单DC:44W 双DC:51W | PSR600W:670W(POE:500W) PSR920W:1058W(POE:820W) PSR1300:1387W(POE:1200W) PSR1600(90VAC~176VAC):1058W(POE:820W) PSR1600(176VAC~290VAC /180VDC~320VDC):1739W(POE:1500W) PSR600W+600W:1330W(POE:1070W) PSR920W+920W:2027W(POE:1650W) PSR1300W+1300W:2678W(POE:2370W) PSR1600W+1600W(90VAC~176VAC):2015W(POE:1650W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):3222W(POE:2900W) | ≤6.7kg | -5℃~50℃ | 5~95%RH |
S5130S-24UN8X-EI-G-V2 | 单AC:37W 双AC:47W 单DC:33W 双DC:38W | PSR600W:642W(POE:530W) PSR920W:1032W(POE:850W) PSR1300:1413W(POE:1230W) PSR1600(90VAC~176VAC):1035W(POE:850W) PSR1600(176VAC~290VAC /180VDC~320VDC):1705W(POE:1530W) PSR600W+600W:1306W(POE:1100W) PSR920W+920W:1994W(POE:1680W) PSR1300W+1300W:2621W(POE:2400W) PSR1600W+1600W(90VAC~176VAC):1979W(POE:1680W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):2568W(POE:2400W) | ≤6.5kg | ||
S5130S-48S6X-EI-G-V2 | 单AC:29W 双AC:30W 单DC:33W 双DC:38W | 单AC:76W 双AC:77W 单DC:82W 双DC:88W | ≤5.9 | ||
S5130S-48T6X-EI-G-V2 | 单AC:38W 双AC:39W 单DC:43W 双DC:45W | 单AC:78W 双AC:77W 单DC:80W 双DC:85W | ≤5.9kg | ||
S5130S-48P6X-EI-G-V2 | 单AC:53W 双AC:61W 单DC:48W 双DC:52W | PSR600W:660W(POE:510W) PSR920W:1048W(POE:830W) PSR1300:1382W(POE:1210W) PSR1600(90VAC~176VAC):1038W(POE:830W) PSR1600(176VAC~290VAC /180VDC~320VDC):1699W(POE:1510W) PSR600W+600W:1306W(POE:1080W) PSR920W+920W:2001W(POE:1660W) PSR1300W+1300W:1980W(POE:1680W) PSR1600W+1600W(90VAC~176VAC):1961W(POE:1680W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):1950W(POE:1680W) | ≤6.7kg | ||
S5130S-28S8T8X-EI-G-V2 | 单AC:28W 双AC:39W 单DC:32W 双DC:36W | 单AC:69W 双AC:72W 单DC:75W 双DC:81W | ≤6.6 | ||
S5130S-28T8X-EI-G-V2 | 单AC:33W 双AC:36W 单DC:40W 双DC:42W | 单AC:67W 双AC:69W 单DC:71W 双DC:73W | ≤6kg | ||
S5130S-28P8X-EI-G-V2 | 单AC:49W 双AC:55W 单DC:44W 双DC:48W | PSR600W:632W(POE:520W) PSR920W:1038W(POE:840W) PSR1300:1140W(POE:980W) PSR1600(90VAC~176VAC):1015W(POE:840W) PSR1600(176VAC~290VAC /180VDC~320VDC):1122W(POE:980W) PSR600W+600W:1138W(POE:980W) PSR920W+920W:1140W(POE:980W) PSR1300W+1300W:1121W(POE:980W) PSR1600W+1600W(90VAC~176VAC):1149W(POE:980W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):1106W(POE:980W) | ≤6.5kg | ||
S5130S-48U6X-EI-G-V2 | 单AC:46W 双AC:54W 单DC:42W 双DC:49W | PSR600W:652W(POE:510W) PSR920W:1040W(POE:830W) PSR1300:1388W(POE:1210W) PSR1600(90VAC~176VAC):1040W(POE:830W) PSR1600(176VAC~290VAC /180VDC~320VDC):1721W(POE:1510W) PSR600W+600W:1314W(POE:1080W) PSR920W+920W:2009W(POE:1660W) PSR1300W+1300W:2660W(POE:2380W) PSR1600W+1600W(90VAC~176VAC):1997W(POE:1660W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):3204W(POE:2910W) | ≤7kg | ||
S5130S-28U4S8X-EI-G-V2 | 单AC:37W 双AC:47W 单DC:32W 双DC:37W | PSR600W:622W(POE:510W) PSR920W:1012W(POE:830W) PSR1300:1383W(POE:1210W) PSR1600(90VAC~176VAC):1015W(POE:830W) PSR1600(176VAC~290VAC /180VDC~320VDC):1685W(POE:1510W) PSR600W+600W:1286W(POE:1080W) PSR920W+920W:1974W(POE:1660W) PSR1300W+1300W:2601W(POE:2380W) PSR1600W+1600W(90VAC~176VAC):1959W(POE:1660W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):3002W(POE:2800W) | ≤6.5kg | ||
S5130S-24N8XC-EI-G-V2 | 单AC:27W 双AC:27W 单DC:34W 双DC:39W | 单AC:70W 双AC:70W 单DC:71W 双DC:74W | ≤6.3kg | -5℃~45℃ | |
S5130S-24UN8XC-EI-G-V2 | 单AC:41W 双AC:50W 单DC:42W 双DC:51W | PSR600W:609W(POE:490W) PSR920W:980W(POE:810W) PSR1300:1351.3W(POE:1190W) PSR1600(90VAC~176VAC):918W(POE:810W) PSR1600(176VAC~290VAC /180VDC~320VDC):1635.1W(POE:1490W) PSR600W+600W:1217.2W(POE:1060W) PSR920W+920W:1954.9W(POE:1640) PSR1300W+1300W:2656.1W(POE:2360W) PSR1600W+1600W(90VAC~176VAC):1861W(POE:1640W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):2723.6W(POE:2500W) | ≤7.3kg | ||
S5130S-48N4XC-EI-G-V2 | 单AC:32W 双AC:33W 单DC:35W 双DC:43W | 单AC:84W 双AC:83W 单DC:80W 双DC:86W | ≤6.4kg | ||
S5130S-48UN4XC-EI-G-V2 | 单AC:52W 双AC:58W 单DC:50W 双DC:57W | PSR600W:624W(POE:470W) PSR920W:978W(POE:790W) PSR1300:1375W(POE:1170W) PSR1600(90VAC~176VAC):977W(POE:790W) PSR1600(176VAC~290VAC /180VDC~320VDC):1677W(POE:1470W) PSR600W+600W:1261W(POE:1040W) PSR920W+920W:1998W(POE:1620W) PSR1300W+1300W:2694W(POE:2340W) PSR1600W+1600W(90VAC~176VAC):2018W(POE:1620W) PSR1600W+1600W(176VAC~290VAC /180VDC~320VDC):3134W(POE:2870W) | ≤7.5kg |
*上行万兆端口中,任意2个端口可切换为12GE专用堆叠口
业务特性
SDN/Openflow | 支持OpenFlow 1.3标准 |
支持多控制器(EQUAL模式、主备模式) | |
支持多表流水线 | |
支持Group table | |
支持Meter | |
端口聚合 | 支持端口聚合 |
支持静态聚合 | |
支持动态聚合 | |
端口特性 | 支持IEEE802.3x 流量控制(全双工)及半双工背压流控 |
支持基于端口速率百分比的风暴抑制 | |
支持基于PPS的风暴抑制 | |
支持基于bps的风暴抑制 | |
Jumbo Frame | 支持最大帧长为13312 |
MAC地址表 | 32K |
支持静态、动态、黑洞MAC地址 | |
支持源MAC地址过滤 | |
支持设置端口MAC地址学习最大个数 | |
VLAN | 支持基于端口的VLAN |
支持QinQ,灵活QinQ | |
支持VLAN Mapping | |
支持802.1Q VLAN | |
支持4K VLAN | |
支持Guest VLAN | |
支持STP、RSTP、MSTP、PVST | |
支持MVRP | |
支持Voice VLAN | |
支持策略VLAN | |
支持基于IP子网的VLAN | |
支持基于协议的VLAN | |
支持基于MAC的VLAN | |
二层环网协议 | 支持STP/RSTP/MSTP/PVST |
支持STP Root Protection | |
支持BPDU Protection | |
支持SmartLink | |
支持RRPP | |
支持ERPS以太环保护协议(G.8032) | |
DHCP | DHCP/DHCPv6 Client |
DHCP/DHCPv6 Snooping | |
DHCP/DHCPv6 Relay | |
DHCP/DHCPv6 Server | |
DHCP/DHCPv6 Snooping option82,DHCP/DHCPv6 Relay option82 | |
IP路由 | 支持静态路由 |
支持RIPv1/v2,RIPng | |
支持OSPFv1/v2,OSPFv3 | |
支持BGP4,BGP4+ for IPv6 | |
支持IS-IS,IS-IS v6 | |
支持等价路由,策略路由 | |
支持VRRP/VRRPv3/VRRPv6 | |
IPv6 | 支持ND(Neighbor Discovery) |
支持PMTU | |
支持IPv6-Ping,IPv6-Tracert,IPv6-Telnet,IPv6-TFTP | |
组播 | 支持IGMP Snooping v1/v2/v3,MLD Snooping v1/v2 |
支持组播VLAN | |
DNS | 支持静态域名解析 |
支持动态域名解析客户端 | |
支持IPv4和IPv6地址 | |
镜像 | 支持流镜像 |
支持N:M端口镜像 | |
支持本地和远程端口镜像(RSPAN) | |
支持802.3ah | |
支持ACL\QoS | 支持L2(Layer 2)~L4(Layer 4)包过滤功能,提供基于源MAC地址、目的MAC地址、源IP(IPv4/IPv6)地址、目的IP(IPv4/IPv6)地址、TCP/UDP端口号、VLAN的流分类 |
支持时间段(Time Range)ACL | |
支持入方向和出方向的双向ACL策略 | |
支持基于VLAN下发ACL | |
支持对端口接收报文的速率和发送报文的速率进行限制,最小粒度为8Kbps | |
支持报文重定向 | |
支持报文的802.1p和DSCP优先级重新标记 | |
支持CAR(Committed Access Rate)功能 | |
每个端口支持8个输出队列,CPU口支持48个队列 | |
支持灵活的队列调度算法,可以同时基于端口和队列进行设置,支持SP(Strict Priority)、WFQ、WRR多种模式。 | |
支持WRED | |
设备虚拟化 | 支持IRF2智能弹性架构 支持分布式设备管理,分布式链路聚合,分布式弹性路由 支持通过标准以太网接口等方式进行堆叠 支持本地堆叠和远程堆叠 支持9台设备堆叠 |
安全特性 | 支持用户分级管理和口令保护 |
支持AAA认证 | |
支持802.1X认证/集中式MAC地址认证 | |
支持RADIUS认证 | |
支持HWTACACS | |
支持SSH 2.0 | |
支持端口隔离 | |
支持端口安全 | |
支持PORTAL认证 | |
支持EAD | |
可支持DHCP Snooping,防止欺骗的DHCP服务器 | |
支持动态ARP检测,ARP限速,防止中间人攻击和ARP拒绝服务 | |
支持BPDU guard, Root guard | |
支持IP/Port/MAC的绑定功能 | |
支持OSPF、RIPv2报文的明文及MD5密文认证 | |
支持MFF | |
支持IP Source Guard | |
支持SAVI | |
支持DDOS防攻击, ARP防攻击, DAI防攻击, 防ICMP攻击 | |
支持CPU保护 | |
支持基础网络保护策略,支持CPU防攻击 | |
支持HTTPs | |
支持PKI(Public Key Infrastructure,公钥基础设施) | |
管理与维护 | 支持XModem/FTP/TFTP加载升级 |
支持命令行接口(CLI),Telnet,Console口进行配置 | |
支持SNMPv1/v2/v3 | |
支持RMON (Remote Monitoring)告警、事件、历史记录 | |
支持iMC智能管理中心 | |
支持Telemetry可视化 | |
支持硬件BFD,最小3ms检测间隔 | |
支持NETCONF网络管理协议 | |
支持WEB网管 | |
支持公有云管理 | |
支持U盘开局 | |
支持Python脚本管理运维 | |
支持系统日志,分级告警,调试信息输出 | |
支持NTP | |
支持SFLOW | |
支持电源的告警功能,风扇、温度告警 | |
支持Ping、Tracert | |
支持VCT(Virtual Cable Test)电缆检测功能 | |
支持LLDP | |
支持Loopback-detection 端口环回检测 | |
支持802.1ag | |
支持NQA | |
支持ID指示灯,可以通过mode灯或端口指示灯闪烁定位设备位置 | |
绿色节能 | 支持EEE(802.3az) |
端口定时down功能(Schedule job) | |
输入电压 | AC:额定电压范围:100V~240V AC,50/60Hz |
DC:输入额定电压范围 -36V~-72V DC |
H3C S5130S-EI-G-V2系列以太网交换机选配:
设备名称 | 描述 |
S5130S-48UN6X-EI-G-V2以太网交换机 | 主机支持双可插拔电源,电源需要另外配置 |
S5130S-24UN8X-EI-G-V2以太网交换机 | |
S5130S-48S6X-EI-G-V2以太网交换机 | |
S5130S-48T6X-EI-G-V2以太网交换机 | |
S5130S-48P6X-EI-G-V2以太网交换机 | |
S5130S-28S8T8X-EI-G-V2以太网交换机 | |
S5130S-28T8X-EI-G-V2以太网交换机 | |
S5130S-28P8X-EI-G-V2以太网交换机 | |
S5130S-48U6X-EI-G-V2以太网交换机 | |
S5130S-28U4S8X-EI-G-V2以太网交换机 | |
S5130S-24N8XC-EI-G-V2以太网交换机 | |
S5130S-24UN8XC-EI-G-V2以太网交换机 | |
S5130S-48N4XC-EI-G-V2以太网交换机 | |
S5130S-48UN4XC-EI-G-V2以太网交换机 |
H3C S5130S-EI-G-V2系列以太网交换机电源模块选购:
项目描述 | 数量范围 |
600W PoE电源模块 | 0-2 |
920W PoE电源模块 | 0-2 |
1600W PoE电源模块 | 0-2 |
1300W PoE直流电源模块 | 0-2 |
180W可插拔直流电源模块 | 0-2 |
70W可插拔交流电源模块 | 0-2 |
H3C S5130S-EI-G-V2系列以太网交换机支持的SFP千兆光模块:
光模块/线缆名称 | 中心波长 | 接口连接器类型 | 接口线缆规格 | 最大传输距离 | |
SFP-GE-T | - | RJ-45 | 双绞线 | 100m | |
SFP-GE-T-D | - | RJ-45 | 双绞线 | 100m | |
SFP-GE-SX-MM850-A | 850nm | LC | 50/125µm多模光纤 | 550m | |
500m | |||||
62.5/125µm多模光纤 | 275m | ||||
220m | |||||
SFP-GE-SX-MM850-D | 850nm | LC | 50/125µm多模光纤 | 550m | |
500m | |||||
62.5/125µm多模光纤 | 275m | ||||
220m | |||||
SFP-GE-LX-SM1310-A | 1310nm | LC | 9/125µm单模光纤 | 10km | |
50/125µm多模光纤 | 550m | ||||
62.5/125µm多模光纤 | 550m | ||||
SFP-GE-LX-SM1310-D | 1310nm | LC | 9/125µm单模光纤 | 10km | |
50/125µm多模光纤 | 550m | ||||
62.5/125µm多模光纤 | 550m | ||||
SFP-GE-LH40-SM1310 | 1310nm | LC | 9/125µm单模光纤 | 40km | |
SFP-GE-LH40-SM1310-D | 1310nm | LC | 9/125µm单模光纤 | 40km | |
SFP-GE-LH40-SM1550 | 1550nm | LC | 9/125µm单模光纤 | 40km | |
SFP-GE-LH80-SM1550 | 1550nm | LC | 9/125µm单模光纤 | 80km | |
SFP-GE-LH80-SM1550-D | 1550nm | LC | 9/125µm单模光纤 | 80km | |
SFP-GE-LH100-SM1550 | 1550nm | LC | 9/125µm单模光纤 | 100km | |
SFP-GE-LX10-SM1310 | 1310nm | LC | 9/125µm单模光纤 | 10km | |
SFP-GE-LH40-SM1310-I | 1310nm | LC | 9/125µm单模光纤 | 40km | |
SFP-GE-LH20-SM1310-I | 1310nm | LC | 9/125µm单模光纤 | 20km | |
SFP-GE-LX-SM1310-BIDI | 需要注意的是:这两个型号的模块需成对使用 | TX:1310 nm RX:1490 nm | LC | 9/125µm单模光纤 | 10km |
SFP-GE-LX-SM1490-BIDI | TX:1490 nm RX:1310 nm | ||||
SFP-GE-LX-SM1310-BIDI-I | 需要注意的是:这两个型号的模块需成对使用 | TX:1310 nm RX:1490 nm | LC | 9/125µm单模光纤 | 10km |
SFP-GE-LX-SM1490-BIDI-I | TX:1490 nm RX:1310 nm | ||||
SFP-GE-LH40-SM1310-BIDI | 需要注意的是:这两个型号的模块需成对使用 | TX:1310 nm RX:1550 nm | LC | 9/125µm单模光纤 | 40km |
SFP-GE-LH40-SM1550-BIDI | TX:1550 nm RX:1310 nm | ||||
SFP-GE-LH70-SM1490-BIDI | 需要注意的是:这两个型号的模块需成对使用 | TX:1490 nm RX:1550 nm | LC | 9/125µm单模光纤 | 70km |
SFP-GE-LH70-SM1550-BIDI | TX:1550 nm RX:1490 nm | ||||
SFP-STACK-Kit | - | - | SFP线缆 | 1.5m | |
H3C S5130S-EI-G-V2系列以太网交换机支持的2.5G SFP光模块:
光模块名称 | 中心波长 | 接口连接器类型 | 接口线缆规格 | 最大传输距离 |
SFP-2.5G-LX10-SM1310-DR-I | 1310nm | LC | 9/125µm单模光纤 | 10km |
H3C S130S-EI-G-V2系列以太网交换机支持的SFP+万兆光模块:
光模块/线缆名称 | 中心波长 | 接口连接器类型 | 接口线缆规格 | 最大传输距离 | |
SFP-XG-SX-MM850-A | 850nm | LC | 50/125µm多模光纤 | 300m | |
82m | |||||
66m | |||||
62.5/125µm多模光纤 | 33m | ||||
26m | |||||
SFP-XG-SX-MM850-D | 850nm | LC | 50/125µm多模光纤 | 300m | |
82m | |||||
66m | |||||
62.5/125µm多模光纤 | 33m | ||||
26m | |||||
SFP-XG-SX-MM850-E | 850nm | LC | 50/125µm多模光纤 | 300m | |
82m | |||||
66m | |||||
62.5/125µm多模光纤 | 33m | ||||
26m | |||||
SFP-XG-LX-SM1310 | 1310nm | LC | 9/125µm单模光纤 | 10km | |
SFP-XG-LX-SM1310-D | 1310nm | LC | 9/125µm单模光纤 | 10km | |
SFP-XG-LX-SM1310-E | 1310nm | LC | 9/125µm单模光纤 | 10km | |
SFP-XG-LH40-SM1550 | 1550nm | LC | 9/125µm单模光纤 | 40km | |
SFP-XG-LH40-SM1550-D | 1550nm | LC | 9/125µm单模光纤 | 40km | |
SFP-XG-LH80-SM1550 | 1550nm | LC | 9/125µm单模光纤 | 80km | |
SFP-XG-LH80-SM1550-D | 1550nm | LC | 9/125µm单模光纤 | 80km | |
SFP-XG-CPRI-IR-SM1310 | 1310nm | LC | 9/125µm单模光纤 | 1.4km | |
SFP-XG-CPRI-LR-SM1310 | 1310nm | LC | 9/125µm单模光纤 | 10km | |
SFP-XG-LX-SM1270-BIDI | 需要注意的是:这两个型号的模块需成对使用 | TX:1270nm RX:1330nm | LC | 9/125µm单模光纤 | 10km |
SFP-XG-LX-SM1330-BIDI | TX:1330nm RX:1270nm | ||||
SFP-XG-LH40-SM1270-BIDI | 需要注意的是:这两个型号的模块需成对使用 | TX:1270nm RX:1330nm | LC | 9/125µm单模光纤 | 40km |
SFP-XG-LH40-SM1330-BIDI | TX:1330nm RX:1270nm | LC | 9/125µm单模光纤 | 40km | |
SFP-XG-LH80-SM1490-BIDI | 需要注意的是:这两个型号的模块需成对使用 | TX:1490 nm RX:1550 nm | LC | 9/125µm单模光纤 | 80km |
SFP-XG-LH80-SM1550-BIDI | TX:1550 nm RX:1490 nm | LC | 9/125µm单模光纤 | 80km | |
LSWM1STK | - | - | SFP+电缆 | 0.65m | |
LSWM2STK | 1.2m | ||||
LSWM3STK | 3m | ||||
LSTM1STK | 5m | ||||
SFP-XG-D-AOC-7M | - | - | SFP+光缆 | 7m | |
SFP-XG-D-AOC-10M | 10m | ||||
SFP-XG-D-AOC-20M | 20m | ||||