H3C Servers HDM2 User Guide-1.XX-6W106

HomeSupportConfigure & DeployUser ManualsH3C Servers HDM2 User Guide-1.XX-6W106
02-Appendix A Sensor Name and Description
Title Size Download
02-Appendix A Sensor Name and Description 52.75 KB

Appendix A

Table 1 Sensor name and description

Sensor type

Sensor name

Sensor description

Temperature

Inlet_Temp

Air inlet temperature (only one available)

Outlet_Temp

Air outlet temperature (only one available)

CPUx_Temp

CPUx core temperature

CPUx_DTS

Remaining temperature before CPU throttling

CPUx_DIMM_Temp

Max. temperature of common DIMMs for CPUx (x represents the CPU number starting from 1, such as 1 and 2)

Front_HD_Max

Max. temperature of front drives

Mid_HD_Max

Max. temperature of middle drives

Rear_HD_Max

Max. temperature of rear drives

Front_NVMe_Max

Max. temperature of front NVMe drives

Mid_NVMe_Max

Max. temperature of middle NVMe drives

Rear_NVMe_Max

Max. temperature of rear NVMe drives

M.2_Max

Max. temperature of M.2 drives

M.2_Zone

M.2 zone temperature

PCH_Temp

PCH temperature

PSUx_Temp

Power supply x air inlet temperature

CPUx_VR_Temp

Max. CPU VR value

PCIex_Temp

PCIe x temperature

OCPx_Temp

OCP card temperature

Busbarx_Zone

BusBar temperature

DSFP_Max

Max. transceiver module temperature

Voltage

CPUx_VCORE

CPUx core voltage

PSUx_VIN

Power supply N input voltage

PSUx_VOUT

Power supply N output voltage

SYS_12V

System 12V voltage (system HSC output voltage)

SYS_5V

System 5V voltage

SYS_3V3_Standby

System 3.3V voltage

SYS_3V_BAT

Voltage of the RTC battery on the system board

CPUx_DDR_VDDQ1

Memory voltage sensor (VDDQ1)

CPUx_DDR_VDDQ2

Memory voltage sensor (VDDQ2)

Current

PSUN_IIN

Power supply N input current

PSUN_IOUT

Power supply N output current

Power

Total_Power

Total chassis power

FAN_Power

Total fan power

CPU_Power

Total CPU power

MEM_Power

Total memory power

DISK_Power

Total drive power

GPU_Power

Total GPU power

PSUx_PIN

Power supply x input power

PSUx_POUT

Power supply x output power

Rotation speed

FANx_Speed

or FANx_F_Speed

or FANx_R_Speed

Rotation speed of fan module x in RPM

or rotation speed of the front fan in fan module x in RPM

or rotation speed of the rear fan in fan module x in RPM

Status

CPUx_Status

CPU x status (x: 0 to n)

CPUx_Chy_Dz

Memory status, including status in the BIOS and MCA error parsing status The sensor is displayed in the following modes:

·     Mode 1:

¡     x represents the CPU number, starting from 1, such as 1 and 2.

¡     y represents the DIMM channel number (channel ID), starting from 1, such as 1 to 8.

¡     z represents the DIMM ID in each channel, starting from 0, such as 0 and 1.

·     Mode 2: x represents the CPU number, A#, B#, C#...

A pound sign (#) represents the DIMM ID in each channel, starting from 0, such as 0 and 1.

A=Channel1

B=Channel2

Watchdog2

System watchdog overflow and action

Sys_Restart

System startup/startup reason

SysShutdown

System shutdown reason

Boards

Exceptional host power outage

Sys_FW_Progress

System firmware (BIOS) and POST status

ACPI_State

ACPI power status

PSUx_Status

System power supply x status (x: 0 to n)

PSU_Mismatch

Overall power status

PSU_Redundant

System power redundancy status

FANx_Status

or FANx_F_Speed

or FANx_R_Speed

Fan x status

Status of front/rear fan in fan module x (x: 0 to n)

A centrifugal fan module includes front and rear fans.

The status sensors for upper and down fans are named in different formats, such as FANx_U_Status and FANx_D_Status, or FANx_U_F_Status,

FANx_U_R_Status, FANx_D_F_Status, and FANx_D_R_Status

Front: Disk_Fx_Status

Rear: Disk_Rx_Status

Middle: Disk_Mx_Status

Drive status (x: 0 to n)

Front:

M2_SSD_Fx_Status

M2_NVMe_Fx_Sts

Rear:

M2_SSD_Rx_Status

M2_NVMe_Rx_Sts

Drive status (x: 0 to 2)

LAN_Leash_Lost

Link status of network adapter ports

PCIe_Status

Overall PCIe alarm status

PCIex_PM_LNK

PCIe link status of port M in standard PCIe slot x

Px_PCIe_Status

PCIe status of the module in standard PCIe slot x

This status indicates the fault status of the PCIe bus and slot with x representing the PCIe slot number, in the range of 0 to n. The status information is obtained by PCIe faults from the BIOS or is interpreted from the MCA register

BMC_Boot_Up

BMC startup

UID_Button

Long press on the UID button on the panel for BMC reset

SEL_Status

SEL status

PCIe_Riserx_PG

Riser card PG status

F_BPx_Status

Status of front drive backplane x (x: 0 to n, depending on product marks)

M_BPx_Status

Status of middle drive backplane x (x: 0 to n, depending on product marks)

R_BPx_Status

Status of rear drive backplane x (x: 0 to n, depending on product marks)

AreaIntrusion

Chassis status

Liquid_Cooler

Liquid-cooled leak sensor

BMC_Boot_Up

BMC startup

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网