HH3C-LswTRAP-MIB
About this MIB
This MIB contains information about notifications for state change of cards and resources on the device.
MIB file name
hh3c-splat-trap.mib
Notifications
hh3cpowerfailure
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.1 |
Failure of a power supply |
Error |
Major |
1.3.6.1.4.1.25506.8.35.12.1.2 (hh3cPowerNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.1
Failure of a power supply
Error
Major
1.3.6.1.4.1.25506.8.35.12.1.2(hh3cPowerNormal)
ON
Description
This notification is generated when a power supply fails or a new power supply is inserted into the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.2.1.1 (hh3cDevMPowerNum) |
Power supply ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.9.1.13 (hh3cDevMFirstTrapTime) |
Timestamp of the notification. |
N |
TimeTicks |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the power supply is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cPowerNormal
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.2 |
Recovery of a power supply from a fault |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.2
Recovery of a power supply from a fault
Recovery
N/A
N/A
ON
Description
This notification is generated when a power supply recovers from an abnormal state.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.2.1.1 (hh3cDevMPowerNum) |
Power supply ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.9.1.13 (hh3cDevMFirstTrapTime) |
Timestamp of the notification. |
N |
TimeTicks |
Standard MIB values. |
Recommended action
No action is required.
hh3cPowerRemoved
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.5 |
Removal of a power supply |
Error |
Minor |
1.3.6.1.4.1.25506.8.35.12.1.23 (hh3cPowerInserted) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.5
Removal of a power supply
Error
Minor
1.3.6.1.4.1.25506.8.35.12.1.23 (hh3cPowerInserted)
ON
Description
This notification is generated when a power supply is removed from the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.2.1.1 (hh3cDevMPowerNum) |
Power supply ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that a power supply is removed from the device.
- If the power supply is removed from the device, no action is required.
- If the power supply is not removed from the device, verify that the power supply is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cfanfailure
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.6 |
Failure of a fan tray |
Error |
Major |
1.3.6.1.4.1.25506.8.35.12.1.7 (hh3cFanNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.6
Failure of a fan tray
Error
Major
1.3.6.1.4.1.25506.8.35.12.1.7(hh3cFanNormal)
ON
Description
This notification is generated when a fan tray fails.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.1.1.1 (hh3cDevMFanNum) |
Fan tray ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.12.2.28 (hh3cDevTrapFanFailureErrcode) |
Reason for the fan tray failure. |
N |
INTEGER |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the fan tray is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cFanNormal
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.7 |
Recovery of a fan tray from a fault. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.7
Recovery of a fan tray from a fault.
Recovery
N/A
N/A
ON
Description
This notification is generated when a fan tray recovers from a fault.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.1.1.1 (hh3cDevMFanNum) |
Fan tray ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cBoardRemoved
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.8 |
Removal of a card |
Error |
Minor |
1.3.6.1.4.1.25506.8.35.12.1.9 (hh3cBoardInserted) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.8
Removal of a card
Error
Minor
1.3.6.1.4.1.25506.8.35.12.1.9(hh3cBoardInserted)
ON
Description
This notification is generated when a card is removed from the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the card is removed from the device.
- If the card is removed from the device, no action is required.
- If the card is not removed from the device, verify that the card is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cBoardInserted
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.9 |
Insertion of a card |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.9
Insertion of a card
Recovery
N/A
N/A
ON
Description
This notification is generated when a card is inserted into the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cBoardFailure
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.10 |
Failure or startup of a card |
Error |
Major |
1.3.6.1.4.1.25506.8.35.12.1.11 (hh3cBoardNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.10
Failure or startup of a card
Error
Major
1.3.6.1.4.1.25506.8.35.12.1.11(hh3cBoardNormal)
ON
Description
This notification is generated when a card is starting up or a fault occurs on the card.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the card is installed correctly.
2.If the issue persists after 24 hours, contact H3C Support.
hh3cBoardNormal
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.11 |
Initialization completion of a card |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.11
Initialization completion of a card
Recovery
N/A
N/A
ON
Description
This notification is generated when a card completes initialization.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cSubcardRemove
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.12 |
Removal of a subcard |
Error |
Minor |
1.3.6.1.4.1.25506.8.35.12.1.13 (hh3cSubcardInsert) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.12
Removal of a subcard
Error
Minor
1.3.6.1.4.1.25506.8.35.12.1.13(hh3cSubcardInsert)
ON
Description
This notification is generated when a subcard is removed from the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.4.1.1 (hh3cLswSubslotIndex) |
Subslot ID |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the subcard is removed from the device.
- If the subcard is removed from the device, no action is required.
- If the subcard is not removed from the device, verify that the subcard is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cSubcardInsert
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.13 |
Insertion of a subcard |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.13
Insertion of a subcard
Recovery
N/A
N/A
ON
Description
This notification is generated when a subcard is inserted into the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.4.1.1 (hh3cLswSubslotIndex) |
Subslot ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cPowerInserted
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.23 |
Insertion of a power supply |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.23
Insertion of a power supply
Recovery
N/A
N/A
ON
Description
This notification is generated when a power supply is inserted into the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.2.1.1 (hh3cDevMPowerNum) |
Power supply ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cCpuRemoved
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.25 |
Removal of a non-default CPU |
Error |
Minor |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.25
Removal of a non-default CPU
Error
Minor
N/A
ON
Description
This notification is generated when a non-default CPU subcard is removed from the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.10.1.1 (hh3cLswCpuIndex) |
CPU ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the non-default CPU is removed from the device.
- If the non-default CPU is removed from the device, no action is required.
- If the non-default CPU is not removed from the device, verify that the non-default CPU is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cCpuFailure
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.26 |
Failure or startup of a non-default CPU |
Error |
Major |
1.3.6.1.4.1.25506.8.35.12.1.27 (hh3cCpuNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.26
Failure or startup of a non-default CPU
Error
Major
1.3.6.1.4.1.25506.8.35.12.1.27(hh3cCpuNormal)
ON
Description
This notification is generated when a non-default CPU is starting up or a fault occurs on it.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.10.1.1 (hh3cLswCpuIndex) |
CPU ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the non-default CPU is installed correctly.
2.If the issue persists after 24 hours, contact H3C Support.
hh3cCpuNormal
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.27 |
Initialization completion of a non-default CPU |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.27
Initialization completion of a non-default CPU
Recovery
N/A
N/A
ON
Description
This notification is generated when a non-default CPU completes initialization.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Member ID of the device. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.10.1.1 (hh3cLswCpuIndex) |
CPU ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cPowerIncompatible
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.28 |
Incompatibility of a power supply with the device |
Error |
Major |
1.3.6.1.4.1.25506.8.35.12.1.2 (hh3cPowerNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.28
Incompatibility of a power supply with the device
Error
Major
1.3.6.1.4.1.25506.8.35.12.1.2(hh3cPowerNormal)
ON
Description
This notification is generated when a power supply is not compatible with the device.
【System impact】
Status control
The notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.9.1.2.1.1 (hh3cDevMPowerNum) |
Power supply ID. |
Y |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the power supply is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cLoadFinished
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.20 |
A card finished loading of the image file. |
Informational |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.20
A card finished loading of the image file.
Informational
N/A
N/A
ON
Description
This notification is generated when a card finishes loading of the image file.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Chassis ID. |
Y |
Integer |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer |
Standard MIB values. |
Recommended action
No action is required.
hh3cBootImageUpdated
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.24 |
Startup software images updated. |
Informational |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.24
Startup software images updated.
Informational
N/A
N/A
ON
Description
This notification is generated when the startup software images are updated.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Chassis ID. |
Y |
Integer |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer |
Standard MIB values. |
Recommended action
No action is required.
hh3cRequestLoading
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.8.35.12.1.18 |
Image loading request received. |
Informational |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.8.35.12.1.18
Image loading request received.
Informational
N/A
N/A
ON
Description
This notification is generated when the loading service end receives an image loading request.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.8.35.18.4.2.1.1 (hh3cLswFrameIndex) |
Chassis ID. |
Y |
Integer |
Standard MIB values. |
1.3.6.1.4.1.25506.8.35.18.4.3.1.1 (hh3cLswSlotIndex) |
Slot ID. |
Y |
Integer |
Standard MIB values. |
Recommended action
No action is required.
1.