- Table of Contents
- Related Documents
-
Title | Size | Download |
---|---|---|
04-HH3C-ENTITY-EXT-MIB | 1.03 MB |
Contents
hh3cEntityExtTemperatureThresholdNotification
hh3cEntityExtCpuUsageThresholdNotfication
hh3cEntityExtMemUsageThresholdNotification
hh3cEntityExtCriticalTemperatureThresholdNotification
hh3cEntityExtTemperatureNormal
hh3cEntityExternalAlarmRecover
hh3cEntityExtCpuUsageThresholdRecover
hh3cEntityExtMemUsageThresholdRecover
hh3cEntityExtMemAllocatedFailed
hh3cEntityExtFanDirectionNotPreferred
hh3cEntityExtMemUsageThresholdOverTrap
hh3cEntityExtMemUsageThresholdRecoverTrap
hh3cEntityExtSystemFatalAlarmOccur
hh3cEntityExtSystemFatalAlarmClear
hh3cEntityExtSystemWarningOccur
hh3cEntityExtSystemWarningClear
hh3cEntityExtBoardFatalAlarmOccur
hh3cEntityExtBoardFatalAlarmClear
hh3cEntityExtBoardWarningOccur
hh3cEntityExtBoardWarningClear
hh3cEntityExtPowerFatalAlarmOccur
hh3cEntityExtPowerFatalAlarmClear
hh3cEntityExtPowerWarningOccur
hh3cEntityExtPowerWarningClear
hh3cEntityExtFanFatalAlarmOccur
hh3cEntityExtFanFatalAlarmClear
hh3cEntityExtVoltageFatalAlarmOccur
hh3cEntityExtVoltageFatalAlarmClear
hh3cEntityExtVoltageAlarmOccur
hh3cEntityExtVoltageAlarmClear
hh3cEntityExtVoltageWarningOccur
hh3cEntityExtVoltageWarningClear
hh3cEntityExtTemperatureFatalAlarmOccur
hh3cEntityExtTemperatureFatalAlarmClear
hh3cEntityExtTemperatureAlarmOccur
hh3cEntityExtTemperatureAlarmClear
hh3cEntityExtTemperatureWarningOccur
hh3cEntityExtTemperatureWarningClear
hh3cEntityExtClockFatalAlarmOccur
hh3cEntityExtClockFatalAlarmClear
hh3cEntityExtClockWarningOccur
hh3cEntityExtClockWarningClear
hh3cEntityExtDiskFatalAlarmOccur
hh3cEntityExtDiskFatalAlarmClear
hh3cEntityExtOpticalFatalAlarmOccur
hh3cEntityExtOpticalFatalAlarmClear
hh3cEntityExtOpticalAlarmOccur
hh3cEntityExtOpticalAlarmClear
hh3cEntityExtOpticalWarningOccur
hh3cEntityExtOpticalWarningClear
hh3cEntityExtInternalLinkFatalAlarmOccur
hh3cEntityExtInternalLinkFatalAlarmClear
hh3cEntityExtInternalLinkAlarmOccur
hh3cEntityExtInternalLinkAlarmClear
hh3cEntityExtInternalLinkWarningOccur
hh3cEntityExtInternalLinkWarningClear
HH3C-ENTITY-EXT-MIB
About this MIB
Use this MIB to obtain entity extended information. Access this MIB to monitor specific entity data, which facilitates management and monitoring on the product through network management.
Products supporting this MIB must first support the ENTITY-MIB MIB.
The following tables show the relationship between the entity extended properties and device entities. Implementation varies by product.
Entity
hh3cEntityExtAdminStatus (R/W)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
Yes
stack
No
other
No
unknown
No
Entity
hh3cEntityExtOperStatus (R)
chassis
No
backplane
No
container
No
power Supply
Yes
fan
Yes
sensor
No
module
Yes
port
Yes
stack
No
other
No
unknown
No
Entity
hh3cEntityExtStandbyStatus (R)
chassis
No
backplane
No
container
No
powerSupply
No
fan
Yes
sensor
No
module
Yes
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtAlarmLight (R)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtCpuUsage (R)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes(Only support the Module Level1)
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtCpuUsageThreshold (R/W)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes(Only support the Module Level1)
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtMemUsage (R)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes(Only support the Module Level1)
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtMemUsageThreshold(R/W)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes(Only support the Module Level1)
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtMemSize (R)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes(Only support the Module Level1)
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtUpTime (R)
chassis
Yes
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtTemperature (R)
chassis
No
backplane
No
container
No
powerSupply
Yes
fan
Yes
sensor
Yes
module
Yes
port
No
stack
No
other
Yes
unknown
No
Entity
hh3cEntityExtTemperatureThreshold(R/W)
chassis
No
backplane
No
container
No
powerSupply
Yes
fan
Yes
sensor
Yes
module
Yes
port
No
stack
No
other
Yes
unknown
No
Entity
hh3cEntityExtVoltage(R)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtVoltageLowThreshold(R/W)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtVoltageHighThreshold(R/W)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtCriticalTemperatureThreshold(R/W)
chassis
No
backplane
No
container
No
powerSupply
No
fan
No
sensor
Yes
module
No
port
No
stack
No
other
No
unknown
No
Entity
hh3cEntityExtMacAddress (R)
chassis
Yes
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
No
port
No
stack
Yes
other
No
unknown
No
Entity
hh3cEntityExtErrorStatus (R)
chassis
No
backplane
Yes
container
Yes
powerSupply
Yes
fan
Yes
sensor
Yes
module
No
port
Yes
stack
No
other
Yes
unknown
Yes
Entity
hh3cEntityExtManuSerialNum (R)
chassis
Yes
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes
port
No
cpu
No
Entity
hh3cEntityExtManuBuildInfo (R)
chassis
Yes
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes
port
No
cpu
No
Entity
hh3cEntityExtMacAddressCount (R)
chassis
Yes
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes
port
Yes
cpu
No
Entity
hh3cEntityExtManuBOM (R)
chassis
Yes
backplane
No
container
No
powerSupply
No
fan
No
sensor
No
module
Yes
port
No
cpu
No
Entity
(R/W: Read/Write)
POWERSUPPLY
FAN
CHASSIS
CONTAINER
MODULE
PORT
CPU
hh3cEntityExtAdminStatus (R/W)
Yes
hh3cEntityExtOperStatus (R)
Yes
Yes
Yes
Yes
hh3cEntityExtStandbyStatus (R)
Yes
Yes
hh3cEntityExtAlarmLight (R)
hh3cEntityExtCpuUsage (R)
Yes
hh3cEntityExtCpuUsageThreshold (R/W)
Yes
hh3cEntityExtMemUsage (R)
Yes
hh3cEntityExtMemUsageThreshold(R/W)
Yes
hh3cEntityExtMemSize (R)
Yes
hh3cEntityExtUpTime (R)
Yes
hh3cEntityExtTemperature (R)
hh3cEntityExtTemperatureThreshold (R/W)
hh3cEntityExtVoltage (R)
hh3cEntityExtVoltageLowThreshold (R/W)
hh3cEntityExtVoltageHighThreshold (R/W)
hh3cEntityExtCriticalTemperatureThreshold
hh3cEntityExtMacAddress
Yes
hh3cEntityExtErrorStatus
NOTE:
Yes indicates that the extended property is supported.
If the read operation returns no such name/instance, the object is not supported in the current entity instance.
MIB file name
hh3c-entity-ext.mib
Notifications
hh3cEntityExtTemperatureThresholdNotification
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.1 |
Temperature of the entity higher than the threshold. |
Error |
Major |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.1
Temperature of the entity higher than the threshold.
Error
Major
N/A
ON
Description
This notification is generated when the temperature of the entity exceeds the upper limit.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature) |
Temperature of the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.13 (hh3cEntityExtTemperatureThreshold) |
Temperature threshold for the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
To resolve the issue:
1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.
2.Identify the reason why the temperature exceeded the upper limit.
3.Verify that the temperature has dropped back to the normal.
4.If the issue persists, contact H3C Support.
hh3cEntityExtCpuUsageThresholdNotfication
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.4 |
CPU usage of the entity higher than the threshold. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.25 (hh3cEntityExtCpuUsageThresholdRecover) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.4
CPU usage of the entity higher than the threshold.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.25(hh3cEntityExtCpuUsageThresholdRecover)
ON
Description
This notification is generated when the CPU usage of the entity exceeds the threshold. The notification is sent every 60 seconds till the alarm is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.6 (hh3cEntityExtCpuUsage) |
CPU usage of the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.7 (hh3cEntityExtCpuUsageThreshold) |
CPU usage threshold for the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
1.3.6.1.4.1.25506.2.6.1.1.1.1.31 (hh3cEntityExtCpuUsageRecoverThreshold) |
CPU usage recovery threshold for the entity. |
N |
Integer32 |
0..100 |
Recommended action
To resolve the issue:
1.If the alarm is automatically cleared, no action is required.
2.If the alarm cannot be automatically cleared, contact H3C Support.
hh3cEntityExtMemUsageThresholdNotification
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.5 |
Memory usage of the entity higher than the threshold. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.26 (hh3cEntityExtMemUsageThresholdRecover) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.5
Memory usage of the entity higher than the threshold.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.26(hh3cEntityExtMemUsageThresholdRecover)
ON
Description
This notification is generated when the total memory size is less than 4 GB and the memory usage of the entity exceeds hh3cEntityExtMemUsageThreshold (memory usage threshold). The notification is sent every 60 seconds till the alarm is cleared.
If the total memory size is equal to or greater than 4 GB, an hh3cEntityExtMemUsageThresholdOverTrap notification is generated when the memory usage exceeds hh3cEntityExtMemUsageThreshold.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage) |
Memory usage of the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold) |
Memory usage threshold for the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.10 (hh3cEntityExtMemSize) |
Memory size of the entity. |
N |
Unsigned32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
To resolve the issue:
1.If the alarm is automatically cleared, no action is required.
2.If the alarm cannot be automatically cleared, contact H3C Support.
hh3cEntityExtCriticalTemperatureThresholdNotification
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.8 |
Temperature of the entity higher than the critical high-temperature threshold. |
Error |
Critical |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.8
Temperature of the entity higher than the critical high-temperature threshold.
Error
Critical
N/A
ON
Description
This notification is generated when the temperature of the entity exceeded the critical high-temperature threshold. The notification is sent every 80 seconds till the alarm is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature) |
Temperature of the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.17 (hh3cEntityExtCriticalTemperatureThreshold) |
Critical high-temperature threshold for the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
To resolve the issue:
1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.
2.Identify the reason why the temperature exceeded the critical high-temperature threshold.
3.Verify that the temperature has dropped back to the normal.
4.If the issue persists, contact H3C Support.
hh3cEntityInsert
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.12 |
Entity installation. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.12
Entity installation.
Recovery
Warning
N/A
ON
Description
This notification is generated when the entity is installed to the device.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.2.1.47.1.1.1.1.2 (entPhysicalDescr) |
Description of the entity. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.3 (hh3cEntityExtOperStatus) |
Operation status of the entity. |
N |
Hh3cOperState |
notSupported(1), disabled(2), enabled(3), dangerous(4) |
Recommended action
No action is required.
hh3cEntityRemove
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.13 |
Entity removal. |
Error |
Minor |
1.3.6.1.4.1.25506.2.6.2.0.12 (hh3cEntityInsert) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.13
Entity removal.
Error
Minor
1.3.6.1.4.1.25506.2.6.2.0.12(hh3cEntityInsert)
ON
Description
This notification is generated when the entity is removed from the device.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.2.1.47.1.1.1.1.2 (entPhysicalDescr) |
Description of the entity. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.3 (hh3cEntityExtOperStatus) |
Operation status of the entity. |
N |
Hh3cOperState |
notSupported(1), disabled(2), enabled(3), dangerous(4) |
Recommended action
To resolve the issue:
1.If the entity was removed from the device, no action is required.
2.If the entity was not removed, verify that the entity is installed correctly.
3.If the issue persists, contact H3C Support.
hh3cEntityExtFaultAlarmOn
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.16 |
Error occurrence on the entity. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.16 (hh3cEntityExtFaultAlarmOff) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.16
Error occurrence on the entity.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.16(hh3cEntityExtFaultAlarmOff)
ON
Description
This notification is generated when an error occurs on the entity.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus) |
Alarm status for the entity. |
N |
INTEGER |
notSupported(1), normal(2), postFailure(3), entityAbsent(4), poeError(11), stackError(21), stackPortBlocked(22), stackPortFailed(23), sfpRecvError(31), sfpSendError(32), sfpBothError(33, fanError(41), psuError(51), rpsError(61), moduleFaulty(71), sensorError(81), hardwareFaulty(91) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
To resolve the issue:
1.Verify that the entity is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cEntityExtFaultAlarmOff
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.17 |
Error clearance. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.17
Error clearance.
Recovery
Warning
N/A
ON
Description
This notification is generated when the entity recovers from the faulty state.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.19 (hh3cEntityExtErrorStatus) |
Alarm status for the entity. |
N |
INTEGER |
notSupported(1), normal(2), postFailure(3), entityAbsent(4), poeError(11), stackError(21), stackPortBlocked(22), stackPortFailed(23), sfpRecvError(31), sfpSendError(32), sfpBothError(33, fanError(41), psuError(51), rpsError(61), moduleFaulty(71), sensorError(81), hardwareFaulty(91) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
No action is required.
hh3cEntityExtTemperatureLower
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.20 |
Temperature of the entity lower than the low-temperature threshold. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.22 (hh3cEntityExtTemperatureNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.20
Temperature of the entity lower than the low-temperature threshold.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.22(hh3cEntityExtTemperatureNormal)
ON
Description
This notification is generated when the temperature of the entity decreases below the low-temperature threshold.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature) |
Temperature of the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.21 (hh3cEntityExtLowerTemperatureThreshold) |
Low-temperature threshold for the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
Recommended action
To resolve the issue:
1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.
2.Identify the reason why the temperature dropped below the lower limit.
3.Verify that the temperature has increased to the normal.
4.If the issue persists, contact H3C Support.
hh3cEntityExtTemperatureTooUp
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.21 |
Temperature of the entity higher than the shutdown temperature threshold. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.2.0.22 (hh3cEntityExtTemperatureNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.21
Temperature of the entity higher than the shutdown temperature threshold.
Error
Critical
1.3.6.1.4.1.25506.2.6.2.0.22(hh3cEntityExtTemperatureNormal)
ON
Description
This notification is generated when the temperature of the entity exceeds the shutdown temperature threshold. The notification is sent every 80 seconds till the alarm is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature) |
Temperature of the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.22 (hh3cEntityExtShutdownTemperatureThreshold) |
Shutdown temperature threshold for the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
Recommended action
To resolve the issue:
1.Verify that the temperature of the environment is normal. Execute the display environment command to obtain temperature information, including the current temperature and the temperature thresholds.
2.Identify the reason why the temperature exceeded the shutdown temperature threshold.
3.Verify that the temperature has dropped back to the normal.
4.If the issue persists, contact H3C Support.
hh3cEntityExtTemperatureNormal
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.22 |
Temperature of the entity back to normal. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.22
Temperature of the entity back to normal.
Recovery
Warning
N/A
ON
Description
This notification is generated when the temperature of the entity recovers from the abnormal status.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature) |
Temperature of the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.21 (hh3cEntityExtLowerTemperatureThreshold) |
Low-temperature threshold for the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.13 (hh3cEntityExtTemperatureThreshold) |
Temperature threshold for the entity. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
Recommended action
No action is required.
hh3cEntityExternalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.23 |
Error on a peripheral of the entity. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.24 (hh3cEntityExternalAlarmRecover) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.23
Error on a peripheral of the entity.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.24(hh3cEntityExternalAlarmRecover)
ON
Description
This notification is generated when an error occurs on the peripheral of the entity.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the entity is installed correctly.
2.If the issue persists, contact H3C Support.
hh3cEntityExternalAlarmRecover
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.24 |
A peripheral of the entity back to normal. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.24
A peripheral of the entity back to normal.
Recovery
Warning
N/A
ON
Description
This notification is generated when the peripheral of the entity recovers from the faulty state.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtCpuUsageThresholdRecover
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.25 |
Recovery of the CPU usage from an alarm threshold. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.25
Recovery of the CPU usage from an alarm threshold.
Recovery
Warning
N/A
ON
Description
This notification is generated when the CPU usage of the entity recovers from the abnormal state.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.6 (hh3cEntityExtCpuUsage) |
CPU usage of the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.7 (hh3cEntityExtCpuUsageThreshold) |
CPU usage threshold for the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
1.3.6.1.4.1.25506.2.6.1.1.1.1.31 (hh3cEntityExtCpuUsageRecoverThreshold) |
CPU usage recovery threshold for the entity. |
N |
Integer32 |
0..100 |
Recommended action
No action is required.
hh3cEntityExtMemUsageThresholdRecover
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.26 |
Recovery of the memory usage from an alarm threshold. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.26
Recovery of the memory usage from an alarm threshold.
Recovery
Warning
N/A
ON
Description
This notification is generated when the memory usage of the entity recovers from the abnormal state.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage) |
Memory usage of the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold) |
Memory usage threshold for the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.10 (hh3cEntityExtMemSize) |
Memory size of the entity. |
N |
Unsigned32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
No action is required.
hh3cEntityExtMemAllocatedFailed
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.27 |
Memory allocation request failure. |
Informational |
Major |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.27
Memory allocation request failure.
Informational
Major
N/A
ON
Description
This notification is generated when memory allocation for the entity failed.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.2.1.1 (hh3cEntityExtTrapDescription) |
Description of the notification. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue, contact H3C Support.
hh3cEntityExtECCParityAlarm
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.28 |
ECC parity check error. |
Informational |
Major |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.28
ECC parity check error.
Informational
Major
N/A
ON
Description
This notification is generated when an ECC parity check error occurs on the entity.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.2.1.1 (hh3cEntityExtTrapDescription) |
Description of the entity. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue, contact H3C Support.
hh3cEntityExtFanDirectionNotPreferred
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.31 |
The airflow direction of a fan tray is different from the preferred airflow direction. |
Error |
Major |
1.3.6.1.4.1.25506.8.35.12.1.7 (hh3cFanNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.31
The airflow direction of a fan tray is different from the preferred airflow direction.
Error
Major
1.3.6.1.4.1.25506.8.35.12.1.7(hh3cFanNormal)
ON
Description
This notification is generated when the airflow direction of a fan tray is different from the preferred airflow direction. The possible reasons include the following:
The preferred airflow direction configuration is incorrect.
An incorrect fan tray is inserted.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Select a fan tray according to the ventilation system in the equipment room. A fan tray can operate effectively only when it uses the same airflow direction as the ventilation system in the equipment room.
2.If the fan tray uses the same airflow direction as the ventilation system in the equipment room, verify that the configured preferred airflow direction is the same as the airflow direction of the fan tray.
hh3cEntityExtMemUsageThresholdOverTrap
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.35 |
Continuous notifications of memory usage exceeding the threshold. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.36 (hh3cEntityExtMemUsageThresholdRecoverTrap) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.35
Continuous notifications of memory usage exceeding the threshold.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.36(hh3cEntityExtMemUsageThresholdRecoverTrap)
ON
Description
This notification is generated when the total memory size of the entity is equal to or greater than 4 GB and the memory usage of the entity exceeds hh3cEntityExtMemUsageThreshold (memory usage threshold). The notification is sent every 60 seconds till the alarm is cleared.
If the total memory size is less than 4 GB, an hh3cEntityExtMemUsageThresholdNotification notification is generated when the memory usage exceeds hh3cEntityExtMemUsageThreshold.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage) |
Memory usage of the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold) |
Memory usage threshold for the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.32 (hh3cEntityExtMemSizeRev) |
Memory size of the entity. |
N |
Counter64 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
To resolve the issue:
1.If the alarm is automatically cleared, no action is required.
2.If the alarm cannot be automatically cleared, contact H3C Support.
hh3cEntityExtMemUsageThresholdRecoverTrap
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.36 |
Recovery of the memory usage from an alarm threshold. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.36
Recovery of the memory usage from an alarm threshold.
Recovery
Warning
N/A
ON
Description
This notification is generated when the memory usage of the entity recovers from the abnormal state.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.8 (hh3cEntityExtMemUsage) |
Memory usage of the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.9 (hh3cEntityExtMemUsageThreshold) |
Memory usage threshold for the entity. |
N |
Integer32 |
0..100 |
1.3.6.1.4.1.25506.2.6.1.1.1.1.32 (hh3cEntityExtMemSizeRev) |
Memory size of the entity. |
N |
Counter64 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.1.1.1.2 (hh3cEntityExtAdminStatus) |
Administrative status of the entity. |
N |
Hh3cAdminState |
notSupported(1), locked(2), shuttingDown(3), unlocked(4)} |
1.3.6.1.4.1.25506.2.6.1.1.1.1.5 (hh3cEntityExtAlarmLight) |
Alarm status of the entity. |
N |
Hh3cAlarmStatus |
BITS {, notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7), } |
Recommended action
No action is required.
hh3cEntityExtVoltageNormal
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.37 |
Recovery of the voltage from an alarm threshold. |
Recovery |
Warning |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.37
Recovery of the voltage from an alarm threshold.
Recovery
Warning
N/A
ON
Description
This notification is generated when the voltage of the entity recovers from the abnormal state.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage) |
Voltage of the entity. |
N |
Integer32 |
Standard MIB values. |
Recommended action
No action is required.
hh3cEntityExtVoltageLower
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.38 |
Voltage of the entity lower than the low-voltage threshold. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.38
Voltage of the entity lower than the low-voltage threshold.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.37(hh3cEntityExtVoltageNormal)
ON
Description
This notification is generated when the voltage of the entity drops below the low-voltage threshold.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage) |
Voltage of the entity. |
N |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the power system of the device is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtVoltageTooLow
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.39 |
Voltage of the threshold lower than critical low-voltage threshold. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.39
Voltage of the threshold lower than critical low-voltage threshold.
Error
Critical
1.3.6.1.4.1.25506.2.6.2.0.37(hh3cEntityExtVoltageNormal)
ON
Description
This notification is generated when the voltage of the entity drops below the critical low-voltage threshold. The notification is sent every 80 seconds till the alarm is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage) |
Voltage of the entity. |
N |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the power system of the device is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtVoltageHigher
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.40 |
Voltage of the entity higher than the high-voltage threshold. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.40
Voltage of the entity higher than the high-voltage threshold.
Error
Major
1.3.6.1.4.1.25506.2.6.2.0.37(hh3cEntityExtVoltageNormal)
ON
Description
This notification is generated when the voltage of the entity increases above the high-voltage threshold.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage) |
Voltage of the entity. |
N |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the power system of the device is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtVoltageTooHigh
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.2.0.41 |
Voltage of the entity higher than the critical high-voltage threshold. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.2.0.37 (hh3cEntityExtVoltageNormal) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.2.0.41
Voltage of the entity higher than the critical high-voltage threshold.
Error
Critical
1.3.6.1.4.1.25506.2.6.2.0.37(hh3cEntityExtVoltageNormal)
ON
Description
This notification is generated when the voltage of the entity increases over the critical high-voltage threshold. The notification is sent every 80 seconds till the alarm is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.1.5.1.1.1 (hh3cEntityExtCurrentVoltage) |
Voltage of the entity. |
N |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1.Verify that the power system of the device is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtSystemFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.1 |
System critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.2 (hh3cEntityExtSystemFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.1
System critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.2(hh3cEntityExtSystemFatalAlarmClear)
ON
Description
This notification is generated when a critical error occurs in the system.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the system status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtSystemFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.2 |
System critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.2
System critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a system critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtSystemAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.3 |
System major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.4 (hh3cEntityExtSystemAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.3
System major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.4(hh3cEntityExtSystemAlarmClear)
ON
Description
This notification is generated when a major error occurs in the system.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the system status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtSystemAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.4 |
System major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.4
System major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a system major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtSystemWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.5 |
System warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.6 (hh3cEntityExtSystemWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.5
System warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.6(hh3cEntityExtSystemWarningClear)
ON
Description
This notification is generated when a warning error occurs in the system.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the system status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtSystemWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.6 |
System warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.6
System warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a system warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtBoardFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.7 |
Card critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.8 (hh3cEntityExtBoardFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.7
Card critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.8(hh3cEntityExtBoardFatalAlarmClear)
ON
Description
This notification is generated when a critical error occurs on a card.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the card status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtBoardFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.8 |
Card critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.8
Card critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a card critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtBoardAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.9 |
Card major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.10 (hh3cEntityExtBoardAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.9
Card major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.10(hh3cEntityExtBoardAlarmClear)
ON
Description
This notification is generated when a major error occurs on a card.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the card status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtBoardAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.10 |
Card major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.10
Card major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a card major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtBoardWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.11 |
Card warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.12 (hh3cEntityExtBoardWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.11
Card warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.12(hh3cEntityExtBoardWarningClear)
ON
Description
This notification is generated when a warning error occurs on a card.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the card status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtBoardWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.2 |
Card warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.2
Card warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a card warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtPowerFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.13 |
Power critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.14 (hh3cEntityExtPowerFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.13
Power critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.14(hh3cEntityExtPowerFatalAlarmClear)
ON
Description
This notification is generated when a power critical error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the power status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtPowerFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.14 |
Power critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.14
Power critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a power critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtPowerAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.15 |
Power major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.15 (hh3cEntityExtPowerAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.15
Power major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.15(hh3cEntityExtPowerAlarmClear)
ON
Description
This notification is generated when a power major error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the power status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtPowerAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.16 |
Power major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.16
Power major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a power major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtPowerWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.17 |
Power warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.18 (hh3cEntityExtPowerWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.17
Power warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.18(hh3cEntityExtPowerWarningClear)
ON
Description
This notification is generated when a power warning error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the power status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtPowerWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.18 |
Power warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.18
Power warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a power warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtFanFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.19 |
Fan critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.20 (hh3cEntityExtFanFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.19
Fan critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.20(hh3cEntityExtFanFatalAlarmClear)
ON
Description
This notification is generated when a critical error occurs on a fan.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the fan status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtFanFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.20 |
Fan critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.20
Fan critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a fan critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtFanAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.21 |
Fan major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.22 (hh3cEntityExtFanAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.21
Fan major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.22(hh3cEntityExtFanAlarmClear)
ON
Description
This notification is generated when a major error occurs on a fan.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the fan status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtFanAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.22 |
Fan major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.22
Fan major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a fan major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtFanWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.23 |
Fan warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.24 (hh3cEntityExtFanWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.23
Fan warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.24(hh3cEntityExtFanWarningClear)
ON
Description
This notification is generated when a warning error occurs on a fan.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the fan status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtFanWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.24 |
Fan warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.24
Fan warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a fan warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtVoltageFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.25 |
Voltage critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.26 (hh3cEntityExtVoltageFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.25
Voltage critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.26(hh3cEntityExtVoltageFatalAlarmClear)
ON
Description
This notification is generated when a voltage critical error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
To resolve the issue:
1.Verify that the voltage information is correct.
2.If the issue persists, contact H3C Support.
hh3cEntityExtVoltageFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.26 |
Voltage critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.26
Voltage critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a voltage critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type, |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
No action is required.
hh3cEntityExtVoltageAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.27 |
Voltage major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.28 (hh3cEntityExtVoltageAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.27
Voltage major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.28(hh3cEntityExtVoltageAlarmClear)
ON
Description
This notification is generated when a voltage major error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
To resolve the issue:
1.Verify that the voltage information is correct.
2.If the issue persists, contact H3C Support.
hh3cEntityExtVoltageAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.2 |
Voltage major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.2
Voltage major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a voltage major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
No action is required.
hh3cEntityExtVoltageWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.29 |
Voltage warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.30 (hh3cEntityExtVoltageWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.29
Voltage warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.30(hh3cEntityExtVoltageWarningClear)
ON
Description
This notification is generated when a voltage warning error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
To resolve the issue:
1.Verify that the voltage information is correct.
2.If the issue persists, contact H3C Support.
hh3cEntityExtVoltageWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.30 |
Voltage warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.30
Voltage warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a voltage warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
No action is required.
hh3cEntityExtTemperatureFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.31 |
Temperature critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.32 (hh3cEntityExtTemperatureFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.31
Temperature critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.32(hh3cEntityExtTemperatureFatalAlarmClear)
ON
Description
This notification is generated when a temperature critical error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
To resolve the issue:
1.Verify that the temperature information is correct.
2.If the issue persists, contact H3C Support.
hh3cEntityExtTemperatureFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.32 |
Temperature critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.32
Temperature critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a temperature critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
No action is required.
hh3cEntityExtTemperatureAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.33 |
Temperature major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.34 (hh3cEntityExtTemperatureAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.33
Temperature major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.34(hh3cEntityExtTemperatureAlarmClear)
ON
Description
This notification is generated when a temperature major error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
To resolve the issue:
1.Verify that the temperature information is correct.
2.If the issue persists, contact H3C Support.
hh3cEntityExtTemperatureAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.34 |
Temperature major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.34
Temperature major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a temperature major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
No action is required.
hh3cEntityExtTemperatureWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.35 |
Temperature warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.36 (hh3cEntityExtTemperatureWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.35
Temperature warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.36(hh3cEntityExtTemperatureWarningClear)
ON
Description
This notification is generated when a temperature warning error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
To resolve the issue:
1.Verify that the temperature information is correct.
2.If the issue persists, contact H3C Support.
hh3cEntityExtTemperatureWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.36 |
Temperature warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.36
Temperature warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a temperature warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 4 (hh3cEntityExtThresholdType) |
Threshold type. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 5 (hh3cEntityExtThresholdVal) |
Value of the threshold. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
1.3.6.1.4.1.25506.2.6.4.1. 6 (hh3cEntityExtCurrentVal) |
Current value. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..63)) |
Recommended action
No action is required.
hh3cEntityExtClockFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.37 |
Clock critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.38 (hh3cEntityExtClockFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.37
Clock critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.38(hh3cEntityExtClockFatalAlarmClear)
ON
Description
This notification is generated when a clock critical error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the clock status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtClockFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.38 |
Clock critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.38
Clock critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a clock critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtClockAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.39 |
Clock major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.40 (hh3cEntityExtClockAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.39
Clock major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.40(hh3cEntityExtClockAlarmClear)
ON
Description
This notification is generated when a clock major error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the clock status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtClockAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.40 |
Clock major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.40
Clock major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a clock major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtClockWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.41 |
Clock warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.42 (hh3cEntityExtClockWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.41
Clock warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.42(hh3cEntityExtClockWarningClear)
ON
Description
This notification is generated when a clock warning error occurs.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the clock status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtClockWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.42 |
Clock warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.42
Clock warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a clock warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtDiskFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.43 |
Disk critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.44 (hh3cEntityExtDiskFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.43
Disk critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.44(hh3cEntityExtDiskFatalAlarmClear)
ON
Description
This notification is generated when a critical error occurs on a disk.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the disk status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtDiskFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.44 |
Disk critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.44
Disk critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a disk critical error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtDiskAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.45 |
Disk major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.46 (hh3cEntityExtDiskAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.45
Disk major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.46(hh3cEntityExtDiskAlarmClear)
ON
Description
This notification is generated when a major error occurs on a disk.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the disk status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtDiskAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.46 |
Disk major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.46
Disk major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a disk major error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtDiskWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.48 |
Disk warning recovery. |
Recovery warning |
_ |
_ (_) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.48
Disk warning recovery.
Recovery warning
_
_
ON
Description
This notification is generated when a warning recovery occurs on a disk.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtDiskWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.48 |
Disk warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.48
Disk warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a disk warning error is cleared.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtOpticalFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.49 |
Transceiver module critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.50 (hh3cEntityExtOpticalFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.49
Transceiver module critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.50(hh3cEntityExtOpticalFatalAlarmClear)
ON
Description
This notification is generated when a critical error occurs on a transceiver module.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the transceiver module status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtOpticalFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.50 |
Transceiver module critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.50
Transceiver module critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a critical error is cleared from a transceiver module.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtOpticalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.51 |
Transceiver module major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.52 (hh3cEntityExtOpticalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.51
Transceiver module major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.52(hh3cEntityExtOpticalAlarmClear)
ON
Description
This notification is generated when a major error occurs on a transceiver module.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the transceiver module status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtOpticalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.52 |
Transceiver module major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.52
Transceiver module major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a major error is cleared from a transceiver module.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtOpticalWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.53 |
Transceiver module warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.54 (hh3cEntityExtOpticalWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.53
Transceiver module warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.54(hh3cEntityExtOpticalWarningClear)
ON
Description
This notification is generated when a warning error occurs on a transceiver module.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the transceiver module status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtOpticalWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.54 |
Transceiver module warning error. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.54
Transceiver module warning error.
Recovery
N/A
N/A
ON
Description
This notification is generated when a warning error is cleared from a transceiver module.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtInternalLinkFatalAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.55 |
Internal link critical error. |
Error |
Critical |
1.3.6.1.4.1.25506.2.6.4.0.56 (hh3cEntityExtInternalLinkFatalAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.55
Internal link critical error.
Error
Critical
1.3.6.1.4.1.25506.2.6.4.0.56(hh3cEntityExtInternalLinkFatalAlarmClear)
ON
Description
This notification is generated when a critical error occurs on an internal link.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the internal link status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtInternalLinkFatalAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.56 |
Internal link critical error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.56
Internal link critical error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a critical error is cleared from an internal link.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtInternalLinkAlarmOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.57 |
Internal link major error. |
Error |
Major |
1.3.6.1.4.1.25506.2.6.4.0.58 (hh3cEntityExtInternalLinkAlarmClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.57
Internal link major error.
Error
Major
1.3.6.1.4.1.25506.2.6.4.0.58(hh3cEntityExtInternalLinkAlarmClear)
ON
Description
This notification is generated when a major error occurs on an internal link.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the internal link status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtInternalLinkAlarmClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.58 |
Internal link major error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.58
Internal link major error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a major error is cleared from an internal link.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.
hh3cEntityExtInternalLinkWarningOccur
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.59 |
Internal link warning error. |
Error |
Warning |
1.3.6.1.4.1.25506.2.6.4.0.60 (hh3cEntityExtInternalLinkWarningClear) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.59
Internal link warning error.
Error
Warning
1.3.6.1.4.1.25506.2.6.4.0.60(hh3cEntityExtInternalLinkWarningClear)
ON
Description
This notification is generated when a warning error occurs on an internal link.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
To resolve the issue:
1.Verify that the internal link status is normal.
2.If the issue persists, contact H3C Support.
hh3cEntityExtInternalLinkWarningClear
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.4.1.25506.2.6.4.0.60 |
Internal link warning error cleared. |
Recovery |
N/A |
N/A (N/A) |
ON |
Notification triggers
Notification Triggers
System impact
OID
Event
Type
Severity
Recovery notification
Default status
1.3.6.1.4.1.25506.2.6.4.0.60
Internal link warning error cleared.
Recovery
N/A
N/A
ON
Description
This notification is generated when a warning error is cleared from an internal link.
【System impact】
Status control
This notification cannot be disabled.
Object
OID (object name) |
Description |
Index |
Type |
Value range |
1.3.6.1.4.1.25506.2.6.1.1.1.1.1 (hh3cEntityExtPhysicalIndex) |
Entity index. |
Y |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.47.1.1.1.1.7 (entPhysicalName) |
Entity name. |
N |
SnmpAdminString |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 1 (hh3cEntityExtRelativeResource) |
Entity location information. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
1.3.6.1.4.1.25506.2.6.4.1. 2 (hh3cEntityExtErrorCode) |
Error code. |
N |
Integer32 |
Standard MIB values. |
1.3.6.1.4.1.25506.2.6.4.1. 3 (hh3cEntityExtReason) |
Reason for the error. |
N |
OCTECT STRING |
OCTET STRING (SIZE (0..255)) |
Recommended action
No action is required.