01-Fundamentals

HomeSupportRoutersH3C SR8800-X Router SeriesDiagnose & MaintainAlarms ReferencesH3C SR8800-X Routers Alarm Reference-R838x-6W10001-Fundamentals
01-HH3C-CONFIG-MAN-MIB
Title Size Download
01-HH3C-CONFIG-MAN-MIB 82.51 KB

HH3C-CONFIG-MAN-MIB

About this MIB

Use this MIB to manage the device configuration. For example, access this MIB to save, back up, or restore the configuration. This MIB also contains notifications about configuration changes.

The following figure shows the relationship among the device memory, local storage medium, and remote server in configuration backup and restoration:

 

MIB file name

hh3c-config-man.mib

Notifications

hh3cCfgManEventlog

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.4.2.1

Configuration change event.

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated as follows:

The save command is used.

A next-startup configuration file is specified.

An operation that affects the next-startup configuration file is performed, for example, copy, rename, and delete.

SNMP detects a data change.

System impact

Change of the system running configuration or next-startup configuration file.

Status control

ON

CLI: Use the snmp-agent trap enable configuration command.

OFF

CLI: Use the undo snmp-agent trap enable configuration command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.4.1.1.7.1.3 (hh3cCfgLogSrcCmd)

Configuration source.

hh3cCfgLogIndex

INTEGER

cmdLine(1), snmp(2)

1.3.6.1.4.1.25506.2.4.1.1.7.1.4 (hh3cCfgLogSrcData)

Source data.

hh3cCfgLogIndex

INTEGER

runningData(2), startupData(4)

1.3.6.1.4.1.25506.2.4.1.1.7.1.5 (hh3cCfgLogDesData)

Destination data.

hh3cCfgLogIndex

INTEGER

runningData(2), startupData(4)

 

Recommended action

Check the system running configuration. If necessary, save the running configuration.

hh3cCfgBackupToServerSuccess

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.4.4.0.1

A configuration file was backed up to a server successfully.

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a configuration file is backed up to a server successfully by using the archive configuration command.

System impact

No impact on services.

Status control

ON

CLI: Use the snmp-agent trap enable configuration command.

OFF

CLI: Use the undo snmp-agent trap enable configuration command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.4.5.1 (hh3cCfgBackupToServerIPType)

Server IP address type.

N/A

InetAddressType

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.2 (hh3cCfgBackupToServerIP)

Server IP address.

N/A

InetAddress

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.3 (hh3cCfgBackupToServerVPNName)

Name of the VPN instance to which the server IP address belongs.

N/A

DisplayString

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.4 (hh3cCfgBackupToServerTransType)

File transfer method.

N/A

INTEGER

As per the MIB.

 

Recommended action

No action is required.

hh3cCfgBackupToServerFailed

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.4.4.0.2

Failed to back up a configuration file to a server.

Informational

Minor

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the system fails to back up a configuration file to a server after the archive configuration command is executed. The failure might be caused by configuration error or link failure.

System impact

Configuration file backup failure.

Status control

ON

CLI: Use the snmp-agent trap enable configuration command.

OFF

CLI: Use the undo snmp-agent trap enable configuration command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.4.5.1 (hh3cCfgBackupToServerIPType)

Server IP address type.

N/A

InetAddressType

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.2 (hh3cCfgBackupToServerIP)

Server IP address.

N/A

InetAddress

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.3 (hh3cCfgBackupToServerVPNName)

Name of the VPN instance to which the server IP address belongs.

N/A

DisplayString

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.4 (hh3cCfgBackupToServerTransType)

File transfer method.

N/A

INTEGER

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.5 (hh3cCfgBackupToServerFailReason)

Backup failure reason.

N/A

DisplayString

As per the MIB.

1.3.6.1.4.1.25506.2.4.5.6 (hh3cCfgBackupToServerErrorCode)

Backup failure error code.

N/A

INTEGER

As per the MIB.

 

Recommended action

1.Use the ping command to verify connectivity between the client and server.

2.Use the device as the client to access the server.

hh3cCfgRestoreSuccess

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.4.4.0.3

The main startup configuration file was restored successfully.

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the main startup configuration file is restored successfully.

System impact

System running configuration change, depending on the configuration that has been restored.

Status control

ON

CLI: Use the snmp-agent trap enable configuration command.

OFF

CLI: Use the undo snmp-agent trap enable configuration command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.4.5.7 (hh3cCfgRestoreType)

Configuration restoration type.

N/A

INTEGER

binary(1), text(2)

 

Recommended action

No action is required.

hh3cCfgSaveFailNotify

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.4.4.0.4

A configuration save operation failed.

Informational

Minor

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a configuration save operation fails.

System impact

The configuration file fails to be saved.

Status control

ON

CLI: Use the snmp-agent trap enable configuration command.

OFF

CLI: Use the undo snmp-agent trap enable configuration command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.4.5.8 (hh3cCfgSaveFailNotifyErrorNumber)

Error code for a configuration save failure.

N/A

Integer32

Integer32 (0..2147483647)

1.3.6.1.4.1.25506.2.4.5.9 (hh3cCfgSaveFailNotifyDateTime)

Time when the configuration save failure occurred.

N/A

DateAndTime

OCTET STRING (8)

1.3.6.1.4.1.25506.2.4.5.10 (hh3cCfgSaveFailNotifySrcChassis)

Number of the chassis where the configuration save failure occurred.

N/A

Integer32

Integer32 (0..2147483647)

1.3.6.1.4.1.25506.2.4.5.11 (hh3cCfgSaveFailNotifySrcSlot)

Number of the slot where the configuration save failure occurred.

N/A

Integer32

Integer32 (0..2147483647)

1.3.6.1.4.1.25506.2.4.5.12 (hh3cCfgSaveFailNotifySrcCpu)

Number of the CPU where the configuration save failure occurred.

N/A

Integer32

Integer32 (0..2147483647)

 

Recommended action

Identify whether a disk damage exists on the active and standby MPUs or the active and standby MPUs have insufficient space.

hh3cCfgFileChange

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.4.4.0.5

A startup configuration file was modified.

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a startup configuration file is modified.

System impact

No impact on services.

Status control

ON

CLI: Use the snmp-agent trap enable configuration command.

OFF

CLI: Use the undo snmp-agent trap enable configuration command.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.4.5.13 (hh3cCfgFileChangeUI)

Source that triggered configuration changes.

N/A

Integer32

Integer32 (0..2147483647)

1.3.6.1.4.1.25506.2.4.5.14 (hh3cCfgFileChangeAction)

Actions that triggered the configuration changes.

N/A

Integer32

Integer32 (0..2147483647)

1.3.6.1.4.1.25506.2.4.5.15 (hh3cCfgFileChangeOperater)

Name of the operator that triggered the configuration changes.

N/A

DisplayString

OCTET STRING (0..255)

1.3.6.1.4.1.25506.2.4.5.16 (hh3cCfgFileChangeOperateTime)

Time when the configuration changes were triggered.

N/A

DateAndTime

OCTET STRING (8)

1.3.6.1.4.1.25506.2.4.5.17 (hh3cCfgFileChangeFileType)

File type that triggered configuration changes:

1 represents the main configuration file.

2 represents the backup configuration file.

N/A

INTEGER

main(1), backup(2)

 

Recommended action

No action is required.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us