- Table of Contents
-
- H3C WX3840X Access Controllers Installation Guide-5W101
- 00-Preface
- 01-Preparing for installation
- 02-Installing the device
- 03-Log in to the device
- 04-Troubleshooting
- 05-Hardware management and maintenance
- 06-Appendix A Chassis views and technical specifications
- 07-Appendix B LEDs
- 08-Appendix C Optional transceiver modules
- Related Documents
-
Title | Size | Download |
---|---|---|
08-Appendix C Optional transceiver modules | 82.84 KB |
7 Optional transceiver modules
Views
You must use an SFP transceiver module and optical fiber with an LC connector to connect the fiber port on the AC.
Figure7-1 SFP transceiver module
Figure7-2 Optical fibers with LC connectors
(1) LC connector |
(2) Optical fiber |
Specifications
A transceiver module that has "MM" in its name supports multi-mode optical fibers. A transceiver module that has "SM" in its name supports single-mode optical fibers.
The H3C transceiver modules are subject to change over time. For the most recent list of H3C transceiver modules, contact Technical Support or marketing staff.
Table7-1 SFP-GE-SX-MM850-A transceiver module specifications
Item |
SFP-GE-SX-MM850-A |
Central wavelength |
850 nm |
Max transmission distance |
550 m (1804.46 ft) |
Data rate |
1250 Mb/s |
Connector type |
Duplex LC connector |
Fiber mode |
MMF |
Fiber diameter |
50 μm |
Output power |
–9.5 to 0 dBm |
Receiver sensitivity |
≤ –17 dBm |
Light saturation |
≤ –3 dBm |
Table7-2 SFP-GE-LX-SM1310-A specifications
Item |
SFP-GE-LX-SM1310-A |
Central wavelength |
1310 nm |
Max transmission distance |
10 km (6.21 miles) |
Data rate |
1250 Mb/s |
Connector type |
Duplex LC connector |
Fiber mode |
SMF |
Fiber diameter |
9 μm |
Output power |
–9.5 to –3 dBm |
Receiver sensitivity |
≤ –20 dBm |
Light saturation |