VXLAN commands· 1

Basic VXLAN commands· 1

ac statistics enable· 1

arp suppression enable· 2

description· 4

display arp suppression vsi 5

display l2vpn interface· 7

display l2vpn mac-address· 9

display l2vpn service-instance· 10

display l2vpn vsi 13

display vxlan tunnel 15

encapsulation· 17

flooding disable· 20

l2vpn enable· 20

l2vpn rewrite inbound tag· 21

l2vpn statistics interval 23

mac-address static vsi 24

mtu· 25

reserved vxlan· 26

reset arp suppression vsi 27

reset l2vpn mac-address· 28

reset l2vpn statistics ac· 29

reset l2vpn statistics tunnel 30

reset l2vpn statistics vsi 32

selective-flooding mac-address· 33

service-class· 34

service-instance· 36

shutdown· 38

statistics enable (Ethernet service instance view) 38

statistics enable (VSI view) 40

tunnel 42

tunnel bfd enable· 42

tunnel statistics enable· 44

vsi 46

vxlan· 47

vxlan fast-forwarding enable· 47

vxlan invalid-udp-checksum discard· 48

vxlan ip-forwarding· 48

vxlan local-mac report 50

vxlan source udp-port acl 51

vxlan source udp-port five-tuple· 53

vxlan tunnel mac-learning disable· 55

vxlan udp-port 55

xconnect vsi 56

VXLAN IP gateway commands· 57

arp distributed-gateway dynamic-entry synchronize· 57

bandwidth· 57

default 58

description· 59

display interface vsi-interface· 59

distributed-gateway local 63

gateway subnet 63

gateway vsi-interface· 64

interface vsi-interface· 65

mac-address· 65

mtu· 66

reset counters interface vsi-interface· 66

shutdown· 67

vtep group member local 68

vtep group member remote· 68

vxlan tunnel arp-learning disable· 69

OVSDB commands· 70

ovsdb server bootstrap ca-certificate· 71

ovsdb server enable· 72

ovsdb server pki domain· 72

ovsdb server pssl 73

ovsdb server ptcp· 74

ovsdb server ssl 75

ovsdb server tcp· 75

vtep access port 76

vtep enable· 77

vxlan tunnel flooding-proxy· 77


VXLAN commands

Basic VXLAN commands

ac statistics enable

Use ac statistics enable to enable packet statistics for a Layer 3 interface that acts as an AC.

Use undo ac statistics enable to disable packet statistics for a Layer 3 interface that acts as an AC.

Syntax

ac statistics enable

undo ac statistics enable

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The packet statistics feature is disabled for a Layer 3 interface that acts as an AC.

Views

Layer 3 aggregate interface view

Layer 3 Ethernet interface view

Predefined user roles

network-admin

context-admin

Usage guidelines

For this command to take effect, you must map the Layer 3 interface to a VSI. If you modify the VSI mapping, packet statistics of the interface are cleared.

Examples

# Map GigabitEthernet 1/0/1 to VSI vsia and enable packet statistics on the interface.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] xconnect vsi vsia

[Sysname-GigabitEthernet1/0/1] ac statistics enable

Related commands

display l2vpn interface verbose

reset l2vpn statistics ac

arp suppression enable

Use arp suppression enable to enable ARP flood suppression.

Use undo arp suppression enable to disable ARP flood suppression.

Syntax

arp suppression enable

undo arp suppression enable

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

Yes

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

Yes

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

Yes

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

Yes

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

Yes

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

Yes

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

Yes

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

Yes

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

Yes

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

Yes

Default

ARP flood suppression is disabled.

Views

VSI view

Predefined user roles

network-admin

context-admin

Usage guidelines

ARP flood suppression reduces ARP request broadcasts by enabling the VTEP to reply to ARP requests on behalf of VMs.

This feature snoops ARP packets to populate the ARP flood suppression table with local and remote MAC addresses. If an ARP request has a matching entry, the VTEP replies to the request on behalf of the VM. If no match is found, the VTEP floods the request to both local and remote sites.

Examples

# Enable ARP flood suppression for VSI vsi1.

<Sysname> system-view

[Sysname] vsi vsi1

[Sysname-vsi-vsi1] arp suppression enable

Related commands

display arp suppression vsi

reset arp suppression vsi

description

Use description to configure a description for a VSI.

Use undo description to restore the default.

Syntax

description text

undo description

Default

A VSI does not have a description.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

text: Specifies a description, a case-sensitive string of 1 to 80 characters.

Examples

# Configure a description for VSI vpn1.

<Sysname> system-view

[Sysname] vsi vpn1

[Sysname-vsi-vpn1] description vsi for vpn1

Related commands

display l2vpn vsi

display arp suppression vsi

Use display arp suppression vsi to display ARP flood suppression entries.

Syntax

display arp suppression vsi [ name vsi-name ] [ slot slot-number ] [ count ]

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

Yes

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

Yes

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

Yes

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

Yes

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

Yes

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

Yes

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

Yes

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

Yes

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

Yes

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

Yes

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

name vsi-name: Specifies a VSI by its name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command displays entries for all VSIs.

slot slot-number: Specifies an IRF member device by its member ID. If you do not specify a member device, this command displays entries on the master device.

count: Displays the number of ARP flood suppression entries that match the command.

Examples

# Display ARP flood suppression entries.

<Sysname> display arp suppression vsi

IP address      MAC address    Vsi Name                        Link ID    Aging

1.1.1.2         000f-e201-0101 vsi1                            0x70000    14

1.1.1.3         000f-e201-0202 vsi1                            0x80000    18

1.1.1.4         000f-e201-0203 vsi2                            0x90000    10

# Display the number of ARP flood suppression entries.

<Sysname> display arp suppression vsi count

Total entries: 3

Table 1 Command output

Field

Description

Link ID

Link ID that uniquely identifies an AC or a VXLAN tunnel on a VSI.

Aging

Remaining lifetime (in minutes) of the ARP flood suppression entry. When the timer expires, the entry is deleted.

 

Related commands

arp suppression enable

reset arp suppression vsi

display l2vpn interface

Use display l2vpn interface to display L2VPN information for Layer 3 interfaces that are mapped to VSIs.

Syntax

display l2vpn interface [ vsi vsi-name | interface-type interface-number ] [ verbose ]

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

vsi vsi-name: Specifies a VSI name, a case-sensitive string of 1 to 31 characters.

interface-type interface-number: Specifies an interface by its type and number.

verbose: Displays detailed information about Layer 3 interfaces. If you do not specify this keyword, the command displays brief information about Layer 3 interfaces.

Usage guidelines

If you do not specify any parameters, this command displays brief L2VPN information for all Layer 3 interfaces that are mapped to VSIs.

Examples

# Display brief L2VPN information for all Layer 3 interfaces that are mapped to VSIs.

<Sysname> display l2vpn interface

Total number of interfaces: 2, 1 up, 1 down

 

Interface                Owner                           Link ID   State    Type

GE1/0/1                  vxlan3                          1         Up       VSI

GE1/0/2                  vxlan4                          2         Down     VSI

Table 2 Command output

Field

Description

Interface

Layer 3 interface name.

Owner

VSI name.

Link ID

The interface's link ID on the VSI.

State

Physical state of the interface:

·     Up—The interface is physically up.

·     Down—The interface is physically down.

Type

L2VPN type of the interface. This field displays VSI for the VXLAN feature.

 

# Display detailed L2VPN information for all Layer 3 interfaces that are mapped to VSIs.

<Sysname> display l2vpn interface verbose

Interface: GE1/0/1

    Owner         : vsi1

    Link ID       : 0

    State         : Up

    Type          : VSI

    Statistics    : Enabled

    Input Statistics:

      Octets   :994496

      Packets  :15539

    Output Statistics:

      Octets   :0

      Packets  :0

 

Interface: GE1/0/2

    Owner         : vsi2

    Link ID       : 0

    State         : Down

    Type          : VSI

    Statistics    : Enabled

    Input Statistics:

      Octets   :0

      Packets  :0

    Output Statistics:

      Octets   :0

      Packets  :0

Table 3 Command output

Field

Description

Interface

Layer 3 interface name.

Owner

VSI name.

Link ID

The interface's link ID on the VSI.

State

Physical state of the interface:

·     Up—The interface is physically up.

·     Down—The interface is physically down.

Type

L2VPN type of the interface. This field displays VSI for the VXLAN feature.

Statistics

Packet statistics state:

·     Enabled—The packet statistics feature is enabled for the interface.

·     Disabled—The packet statistics feature is disabled for the interface.

Input Statistics

Incoming traffic statistics:

·     Octets—Number of incoming bytes.

·     Packets—Number of incoming packets.

Output Statistics

Outgoing traffic statistics:

·     Octets—Number of outgoing bytes.

·     Packets—Number of outgoing packets.

 

display l2vpn mac-address

Use display l2vpn mac-address to display MAC address entries for VSIs.

Syntax

display l2vpn mac-address [ vsi vsi-name ] [ dynamic ] [ count ]

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

vsi vsi-name: Specifies a VSI name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command displays MAC address entries for all VSIs.

dynamic: Specifies dynamic MAC address entries learned in the data plane. If you do not specify this keyword, the command displays all MAC address entries, including:

·     Dynamic remote- and local-MAC entries.

·     Manually added static remote-MAC entries.

VXLAN does not support static local-MAC entries.

count: Displays the number of MAC address entries. If you do not specify this keyword, the command displays detailed information about MAC address entries.

Examples

# Display MAC address entries for all VSIs.

<Sysname> display l2vpn mac-address

MAC Address      State    VSI Name                        Link ID/Name  Aging

0000-0000-000b   Static   vpn1                            Tunnel10      NotAging

0000-0000-000c   Dynamic  vpn1                            Tunnel60      Aging

0000-0000-000d   Dynamic  vpn1                            Tunnel99      Aging

--- 3 mac address(es) found  ---

# Display the total number of MAC address entries in all VSIs.

<Sysname> display l2vpn mac-address count

3 mac address(es) found

Table 4 Command output

Field

Description

State

Entry state:

·     Dynamic—Local- or remote-MAC entry dynamically learned in the data plane.

·     Static—Static remote-MAC entry.

Link ID/Name

For a local MAC address, this field displays the AC's link ID on the VSI.

For a remote MAC address, this field displays the tunnel interface name.

Aging

Entry aging state:

·     Aging.

·     NotAging.

 

Related commands

reset l2vpn mac-address

display l2vpn service-instance

Use display l2vpn service-instance to display information about Ethernet service instances.

Syntax

display l2vpn service-instance [ interface interface-type interface-number [ service-instance instance-id ] ] [ verbose ]

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

interface interface-type interface-number: Specifies a Layer 2 Ethernet interface or Layer 2 aggregate interface by its interface type and number. If you do not specify an interface, this command displays Ethernet service instance information for all Layer 2 Ethernet interfaces and Layer 2 aggregate interfaces.

service-instance instance-id: Specifies an Ethernet service instance by its ID in the range of 1 to 4096. If you do not specify an Ethernet service instance, this command displays information about all Ethernet service instances on the specified Layer 2 Ethernet interface or Layer 2 aggregate interface.

verbose: Displays detailed information about Ethernet service instances. If you do not specify this keyword, the command displays brief information about Ethernet service instances.

Examples

# Display brief information about all Ethernet service instances.

<Sysname> display l2vpn service-instance

Total number of service-instances: 4, 4 up, 0 down

Total number of ACs: 2, 2 up, 0 down

 

Interface                SrvID Owner                           LinkID State Type

GE1/0/1                  3     vsi12                           1      Up    VSI

GE1/0/1                  4     vsi13                           1      Up    VSI

Table 5 Command output

Field

Description

Total number of ACs

Total number of attachment circuits (ACs) and the number of ACs in each state (up or down).

Interface

Name of a Layer 2 Ethernet interface or Layer 2 aggregate interface.

SrvID

Ethernet service instance ID.

Owner

VSI name. This field is empty if an Ethernet service instance is not mapped to any VSI.

LinkID

Ethernet service instance's link ID on the VSI.

State

Ethernet service instance state:

·     Up.

·     Down.

Type

L2VPN type of the Ethernet service instance:

·     VSI.

·     VPWS.

 

# Display detailed information about all Ethernet service instances on GigabitEthernet 1/0/1.

<Sysname> display l2vpn service-instance interface gigabitethernet 1/0/1 verbose

Interface: GE1/0/1

  Service Instance: 1

    Encapsulation : s-vid 16

    VSI Name      : vsi10

    Link ID       : 1

    State         : Up

    Statistics    : Enabled

    Input Statistics:

      Octets   :0

      Packets  :0

    Output Statistics:

      Octets   :0

      Packets  :0

Table 6 Command output

Field

Description

Interface

Name of a Layer 2 Ethernet interface or Layer 2 aggregate interface.

Service Instance

Ethernet service instance ID.

Encapsulation

Frame match criterion of the Ethernet service instance. If the Ethernet service instance does not contain a match criterion, the command does not display this field.

Link ID

Ethernet service instance's link ID on the VSI.

State

Ethernet service instance state:

·     Up.

·     Down.

Statistics

Packet statistics state:

·     Enabled—The packet statistics feature is enabled for the Ethernet service instance.

·     Disabled—The packet statistics feature is disabled for the Ethernet service instance.

Input Statistics

Incoming traffic statistics:

·     Octets—Number of incoming bytes.

·     Packets—Number of incoming packets.

Output Statistics

Outgoing traffic statistics:

·     Octets—Number of outgoing bytes.

·     Packets—Number of outgoing packets.

 

Related commands

service-instance

display l2vpn vsi

Use display l2vpn vsi to display information about VSIs.

Syntax

display l2vpn vsi [ name vsi-name ] [ verbose ]

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

name vsi-name: Specifies a VSI by its name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command displays information about all VSIs.

verbose: Displays detailed information about VSIs. If you do not specify this keyword, the command displays brief information about VSIs.

Examples

# Display brief information about all VSIs.

<Sysname> display l2vpn vsi

Total number of VSIs: 1, 1 up, 0 down, 0 admin down

 

VSI Name                        VSI Index       MTU    State

vpna                            0               1500   Up

Table 7 Command output

Field

Description

MTU

MTU on the VSI.

State

VSI state:

·     Up—The VSI is up.

·     Down—The VSI is down.

·     Admin down—The VSI has been manually shut down by using the shutdown command.

 

# Display detailed information about all VSIs.

<Sysname> display l2vpn vsi verbose

VSI Name: vpna

  VSI Index               : 0

  VSI State               : Up

  MTU                     : 1500

  Bandwidth               : -

  Broadcast Restrain      : -

  Multicast Restrain      : -

  Unknown Unicast Restrain: -

  MAC Learning            : Enabled

  MAC Table Limit         : -

  MAC Learning rate       : -

  Drop Unknown            : Disabled

  PW Redundancy           : Slave

  Flooding                : Enabled

  Service Class           : -

  Gateway Interface       : VSI-interface 100

  VXLAN ID                : 10

  Tunnel Statistics       : Disabled

  Tunnels:

    Tunnel Name          Link ID    State  Type      Flood Proxy  Split horizon

    Tunnel1              0x5000001  Up     Manual    Disabled     Enabled

    Tunnel2              0x5000002  Up     Manual    Disabled     Enabled

  ACs:

    AC                               Link ID    State

    GE1/0/1                          0          Up

Table 8 Command output

Field

Description

VSI Description

Description of the VSI. If the VSI does not have a description, the command does not display this field.

VSI State

VSI state:

·     Up—The VSI is up.

·     Down—The VSI is down.

·     Administratively down—The VSI has been manually shut down by using the shutdown command.

MTU

MTU on the VSI.

Bandwidth

Maximum bandwidth (in kbps) for known unicast traffic on the VSI. This field displays a hyphen (-) if it is not available in the current software version.

Broadcast Restrain

Broadcast restraint bandwidth (in kbps). This field displays a hyphen (-) if it is not available in the current software version.

Multicast Restrain

Multicast restraint bandwidth (in kbps). This field displays a hyphen (-) if it is not available in the current software version.

Unknown Unicast Restrain

Unknown unicast restraint bandwidth (in kbps). This field displays a hyphen (-) if it is not available in the current software version.

MAC Learning

State of the MAC learning feature.

MAC Table Limit

Maximum number of MAC address entries on the VSI. This field displays a hyphen (-) if it is not available in the current software version.

MAC Learning Rate

MAC address entry learning rate of the VSI.

Drop Unknown

Action on source MAC-unknown frames received after the maximum number of MAC entries is reached.

Service Class

Service class value of outgoing VXLAN packets.

Gateway Interface

VSI interface name.

Tunnel Statistics

Packet statistics state:

·     Enabled—The packet statistics feature is enabled for the VXLAN tunnels of the VSI.

·     Disabled—The packet statistics feature is disabled for the VXLAN tunnels of the VSI.

State

Tunnel state:

·     Up—The tunnel is operating correctly.

·     Blocked—The tunnel is a backup proxy tunnel. Its tunnel interface is up, but the tunnel is blocked because the primary proxy tunnel is operating correctly. ‌

·     Defect—The tunnel interface is up, but BFD cannot detect the remote VTEP. This state is not supported in the current software version.

·     Down—The tunnel interface is down.

Type

Tunnel assignment method. Manual indicates that the tunnel was manually assigned to the VXLAN.

Flood Proxy

Flood proxy state:

·     Enabled—Flood proxy is enabled. The VTEP sends broadcast, multicast, and unknown unicast traffic to a flood proxy server through the tunnel. The flood proxy server replicates and forwards flood traffic to remote VTEPs.

·     Disabled—Flood proxy is disabled.

Split horizon

State of split horizon:

·     Enabled—Split horizon is enabled on the VXLAN tunnel. The VXLAN tunnel does not forward the traffic that is received on other VXLAN tunnels.

·     Disabled—Split horizon is disabled on the VXLAN tunnel. The VXLAN tunnel forwards the traffic that is received on other VXLAN tunnels.

ACs

ACs that are bound to the VSI.

Link ID

AC's link ID on the VSI.

State

AC state:

·     Up.

·     Down.

 

display vxlan tunnel

Use display vxlan tunnel to display VXLAN tunnel information for VXLANs.

Syntax

display vxlan tunnel [ vxlan-id vxlan-id [ tunnel tunnel-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

vxlan-id: Specifies a VXLAN ID in the range of 0 to 16777215. If you do not specify a VXLAN, this command displays VXLAN tunnel information for all VXLANs.

tunnel tunnel-number: Specifies a VXLAN tunnel. The tunnel-number argument represents the tunnel interface number. The value range for the tunnel-number argument is 0 to 1023. If you do not specify a VXLAN tunnel, this command displays information about all VXLAN tunnels associated with the specified VXLAN.

 

Examples

# Display VXLAN tunnel information for all VXLANs.

<Sysname> display vxlan tunnel

Total number of VXLANs: 1

 

VXLAN ID: 10, VSI name: vpna, Total tunnels: 3 (3 up, 0 down, 0 defect, 0 blocked)

Tunnel name          Link ID    State  Type         Flood proxy  Split horizon

Tunnel1              0x5000001  Up     Manual       Disabled     Enabled

Tunnel2              0x5000002  Up     Manual       Disabled     Enabled

# Display VXLAN tunnel information for VXLAN 10.

<Sysname> display vxlan tunnel vxlan-id 10

VXLAN ID: 10, VSI name: vpna, Total tunnels: 3 (3 up, 0 down, 0 defect, 0 blocked)

Tunnel name          Link ID    State  Type         Flood proxy  Split horizon

Tunnel1              0x5000001  Up     Manual       Disabled     Enabled

Tunnel2              0x5000002  Up     Manual       Disabled     Enabled

# Display information about VXLAN tunnel 0 for VXLAN 10.

<Sysname> display vxlan tunnel vxlan-id 10 tunnel 0

Interface: Tunnel0

  Link ID    : 0x5000000

  State      : Up

  Type       : Auto

  Flood Proxy: Disabled

  Statistics : Enabled

    Input statistics:

      Octets : 994496

      Packets: 15539

    Output statistics:

      Octets : 0

      Packets: 0

Table 9 Command output

Field

Description

Link ID

Tunnel's link ID in the VXLAN.

State

Tunnel state:

·     Up—The tunnel is operating correctly.

·     Blocked—The tunnel is a backup proxy tunnel. Its tunnel interface is up, but the tunnel is blocked because the primary proxy tunnel is operating correctly. ‌

·     Defect—The tunnel interface is up, but BFD cannot detect the remote VTEP. This state is not supported in the current software version.

·     Down—The tunnel interface is down.

Type

Tunnel assignment method. Manual indicates that tunnel was manually assigned to the VXLAN.

Flood proxy

Flood proxy state:

·     Enabled—Flood proxy is enabled. The VTEP sends broadcast, multicast, and unknown unicast traffic to a flood proxy server through the tunnel. The flood proxy server replicates and forwards flood traffic to remote VTEPs.

·     Disabled—Flood proxy is disabled.

Split horizon

State of split horizon:

·     Enabled—Split horizon is enabled on the VXLAN tunnel. The VXLAN tunnel does not forward the traffic that is received on other VXLAN tunnels.

·     Disabled—Split horizon is disabled on the VXLAN tunnel. The VXLAN tunnel forwards the traffic that is received on other VXLAN tunnels.

Statistics

Packet statistics state:

·     Enabled—The packet statistics feature is enabled for the VXLAN tunnel.

·     Disabled—The packet statistics feature is disabled for the VXLAN tunnel.

Input statistics

Incoming traffic statistics:

·     Octets—Number of incoming bytes.

·     Packets—Number of incoming packets.

Output statistics

Outgoing traffic statistics:

·     Octets—Number of outgoing bytes.

·     Packets—Number of outgoing packets.

Related commands

tunnel

vxlan

encapsulation

Use encapsulation to configure a frame match criterion for an Ethernet service instance.

Use undo encapsulation to restore the default.

Syntax

encapsulation s-vid vlan-id-list [ only-tagged ]

encapsulation s-vid vlan-id c-vid { vlan-id-list | all }

encapsulation c-vid vlan-id-list

encapsulation { default | tagged | untagged }

undo encapsulation

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

An Ethernet service instance does not contain a frame match criterion.

Views

Ethernet service instance view

Predefined user roles

network-admin

context-admin

Parameters

s-vid: Matches frames that are tagged with the specified outer 802.1Q VLAN IDs.

c-vid: Matches frames that are tagged with the specified inner 802.1Q VLAN IDs.

vlan-id: Specifies an 802.1Q VLAN ID in the range of 1 to 4094.

vlan-id-list: Specifies a space-separated list of up to eight VLAN items. Each item specifies a VLAN ID or a range of VLAN IDs in the format of vlan-id1 to vlan-id2. The value range for VLAN IDs is 1 to 4094.

only-tagged: Matches tagged frames. If the outer 802.1Q VLAN is not the PVID, the matching result does not differ, whether or not you specify the only-tagged keyword. If the outer 802.1Q VLAN is the PVID, the matching result depends on whether or not the only-tagged keyword is specified.

·     To match only PVID-tagged frames, specify the only-tagged keyword.

·     To match both untagged frames and PVID-tagged frames, do not specify the only-tagged keyword.

all: Specifies all 802.1Q VLAN IDs.

default: Matches frames that do not match any other Ethernet service instance on the interface. On an interface, you can configure this criterion only in one Ethernet service instance. The Ethernet service instance matches any frames if it is the only instance on the interface.

tagged: Matches any frames that have an 802.1Q VLAN tag.

untagged: Matches any frames that do not have an 802.1Q VLAN tag.

Usage guidelines

An Ethernet service instance can contain only one match criterion. To change the match criterion, first execute the undo encapsulation command to remove the original criterion. When you remove the match criterion in an Ethernet service instance, the mapping between the service instance and the VSI is removed automatically.

Examples

# Configure Ethernet service instance 1 on GigabitEthernet 1/0/1 to match frames that have an outer 802.1Q VLAN ID of 111.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] service-instance 1

[Sysname-GigabitEthernet1/0/1-srv1] encapsulation s-vid 111

Related commands

display l2vpn service-instance

flooding disable

Use flooding disable to disable flooding for a VSI.

Use undo flooding disable to enable flooding for a VSI.

Syntax

flooding disable

undo flooding disable

Default

Flooding is enabled for a VSI.

Views

VSI view

Predefined user roles

network-admin

context-admin

Usage guidelines

By default, the device floods unknown unicast frames received from the local site to the following interfaces in the frame's VXLAN:

·     All site-facing interfaces except for the incoming interface.

·     All VXLAN tunnel interfaces.

To confine unknown unicast traffic to the site-facing interfaces, use this command to disable flooding for the VSI bound to the VXLAN. The VSI will not flood unknown unicast frames to VXLAN tunnel interfaces.

Examples

# Disable flooding for VSI vsi1.

<Sysname> system-view

[Sysname] vsi vsi1

[Sysname-vsi-vsi1] flooding disable

l2vpn enable

Use l2vpn enable to enable L2VPN.

Use undo l2vpn enable to disable L2VPN.

Syntax

l2vpn enable

undo l2vpn enable

Default

L2VPN is disabled.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

You must enable L2VPN before you can configure L2VPN settings.

Examples

# Enable L2VPN.

<Sysname> system-view

[Sysname] l2vpn enable

l2vpn rewrite inbound tag

Use l2vpn rewrite inbound tag to configure the VLAN tag processing rule for incoming traffic.

Use undo l2vpn rewrite inbound to restore the default.

Syntax

l2vpn rewrite inbound tag { nest { c-vid vlan-id | s-vid vlan-id [ c-vid vlan-id ] } | remark 1-to-2 s-vid vlan-id c-vid vlan-id } [ symmetric ]

undo l2vpn rewrite inbound

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

VLAN tags of incoming traffic are not processed.

Views

Layer 3 aggregate interface view

Layer 3 Ethernet interface view

Predefined user roles

network-admin

context-admin

Parameters

nest: Adds VLAN tags.

c-vid: Specifies an inner VLAN tag.

s-vid: Specifies an outer VLAN tag.

vlan-id: Specifies a VLAN ID in the range of 1 to 4094.

remark: Maps VLAN tags.

1-to-2: Performs one-to-two mapping to replace the VLAN tag of single tagged packets with the specified outer and inner VLAN tags.

symmetric: Applies the reverse VLAN tag processing rule to outgoing traffic. If you do not specify this keyword, VLAN tags of outgoing traffic are not processed.

Usage guidelines

To modify the VLAN tag processing rule for incoming traffic, first execute the undo l2vpn rewrite inbound command to remove the existing rule, and then execute the l2vpn rewrite inbound command.

When you use this command, follow these restrictions:

·     The l2vpn rewrite inbound tag nest s-vid vlan-id c-vid vlan-id command takes effect only on untagged packets.

·     The l2vpn rewrite inbound tag remark 1-to-2 command takes effect only on single tagged packets.

Examples

# Configure Layer 3 Ethernet interface GigabitEthernet 1/0/1 to add outer VLAN tag 100 to incoming frames and remove outer VLAN tag 100 from outgoing frames.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] l2vpn rewrite inbound tag nest s-vid 100 symmetric

l2vpn statistics interval

Use l2vpn statistics interval to set the VXLAN statistics collection interval.

Use undo l2vpn statistics interval to restore the default.

Syntax

l2vpn statistics interval interval

undo l2vpn statistics interval

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The VXLAN statistics collection interval is 15 minutes.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

interval: Specifies an interval value in the range of 30 to 65535 seconds.

Examples

# Set the VXLAN statistics collection interval to 30 seconds.

<Sysname> system-view

[Sysname] l2vpn statistics interval 30

mac-address static vsi

Use mac-address static vsi to add a static remote-MAC address entry for a VXLAN VSI.

Use undo mac-address static vsi to remove static remote-MAC address entries for a VXLAN VSI.

Syntax

mac-address static mac-address interface tunnel tunnel-number vsi vsi-name

undo mac-address static [ mac-address ] [ interface tunnel tunnel-number ] vsi vsi-name

Default

VXLAN VSIs do not have static remote-MAC address entries.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

mac-address: Specifies a MAC address in H-H-H format. Do not specify a multicast MAC address or an all-zeros MAC address. You can omit the consecutive zeros at the beginning of each segment. For example, you can enter f-e2-1 for 000f-00e2-0001.

interface tunnel tunnel-number: Specifies a VXLAN tunnel interface by its tunnel interface number. The value range for the tunnel-number argument is 0 to 1023.

 

vsi vsi-name: Specifies a VSI name, a case-sensitive string of 1 to 31 characters.

Usage guidelines

A remote MAC address is the MAC address of a VM in a remote site. Remote MAC entries can be manually added or dynamically learned.

When you add a remote MAC address entry, make sure the specified VSI's VXLAN has been assigned the specified VXLAN tunnel.

The undo mac-address static vsi vsi-name command removes all static MAC address entries for a VSI.

Examples

# Add MAC address 000f-e201-0101 to VSI vsi1. Specify Tunnel-interface 1 as the outgoing interface.

<Sysname> system-view

[Sysname] mac-address static 000f-e201-0101 interface tunnel 1 vsi vsi1

Related commands

vxlan tunnel mac-learning disable

mtu

Use mtu to set the MTU for a VSI.

Use undo mtu to restore the default.

Syntax

mtu size

undo mtu

Default

The default MTU of a VSI is 1500 bytes.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

size: Specifies an MTU value. The value range for this argument is 300 to 65535.

Usage guidelines

The MTU set by using this command limits the maximum length of the packets that a VSI receives from ACs and forwards through VXLAN tunnels. The MTU does not limit the maximum length of other packets in the VXLAN VSI.

Fragmentation is disabled for a VSI that uses the default MTU. If you set a MTU for a VSI, the packets longer than the MTU are fragmented.

Examples

# Set the MTU to 1400 bytes for VSI vxlan1.

<Sysname> system-view

[Sysname] vsi vxlan1

[Sysname-vsi-vxlan1] mtu 1400

Related commands

display l2vpn vsi

reserved vxlan

Use reserved vxlan to specify a reserved VXLAN.

Use undo reserved vxlan to restore the default.

Syntax

reserved vxlan vxlan-id

undo reserved vxlan

Default

No VXLAN has been reserved.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

vxlan-id: Specifies a VXLAN ID in the range of 0 to 16777215.

Usage guidelines

You can specify only one reserved VXLAN on the VTEP. The reserved VXLAN cannot be the VXLAN created on any VSI.

Examples

# Specify VXLAN 10000 as the reserved VXLAN.

<Sysname> system-view

[Sysname] reserved vxlan 10000

reset arp suppression vsi

Use reset arp suppression vsi to clear ARP flood suppression entries on VSIs.

Syntax

reset arp suppression vsi [ name vsi-name ]

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

Yes

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

Yes

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

Yes

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

Yes

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

Yes

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

Yes

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

Yes

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

Yes

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

Yes

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

Yes

Views

User view

Predefined user roles

network-admin

context-admin

Parameters

name vsi-name: Specifies a VSI by its name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command clears ARP flood suppression entries on all VSIs.

Examples

# Clear ARP flood suppression entries on all VSIs.

<Sysname> reset arp suppression vsi

This command will delete all entries. Continue? [Y/N]:y

Related commands

arp suppression enable

display arp suppression vsi

reset l2vpn mac-address

Use reset l2vpn mac-address to clear dynamic MAC address entries on VSIs.

Syntax

reset l2vpn mac-address [ vsi vsi-name ]

Views

User view

Predefined user roles

network-admin

context-admin

Parameters

vsi vsi-name: Specifies a VSI by its name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command clears all dynamic MAC address entries on all VSIs.

Usage guidelines

Use this command when the number of dynamic MAC address entries reaches the limit or the device learns incorrect MAC addresses.

Examples

# Clear the dynamic MAC address entries on VSI vpn1.

<Sysname> reset l2vpn mac-address vsi vpn1

Related commands

display l2vpn mac-address vsi

reset l2vpn statistics ac

Use reset l2vpn statistics ac to clear packet statistics on ACs.

Syntax

reset l2vpn statistics ac [ interface interface-type interface-number [ service-instance instance-id ] ]

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Views

User view

Predefined user roles

network-admin

context-admin

Parameters

interface interface-type interface-number: Specifies an interface by its type and number.

service-instance instance-id: Specifies an Ethernet service instance ID in the range of 1 to 4096. You must specify this option if the interface interface-type interface-number option specifies a Layer 2 interface. You cannot specify this option if the interface interface-type interface-number option specifies a Layer 3 interface.

Usage guidelines

If you do not specify any parameters, this command clears packet statistics on all ACs.

Examples

# Clear packet statistics for Layer 3 interface GigabitEthernet 1/0/1.

<Sysname> reset l2vpn statistics ac interface gigabitethernet 1/0/1

Related commands

ac statistics enable

display l2vpn interface

display l2vpn service-instance verbose

statistics enable (Ethernet service instance view)

reset l2vpn statistics tunnel

Use reset l2vpn statistics tunnel to clear packet statistics on VXLAN tunnel interfaces.

Syntax

reset l2vpn statistics tunnel [ vsi vsi-name ]

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Views

User view

Predefined user roles

network-admin

context-admin

Parameters

vsi vsi-name: Specifies a VSI by its name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command clears packet statistics on VXLAN tunnel interfaces of all VSIs.

Examples

# Clear packet statistics on VXLAN tunnel interfaces of all VSIs.

<Sysname> reset l2vpn statistics tunnel

Related commands

tunnel statistics enable

reset l2vpn statistics vsi

Use reset l2vpn statistics vsi to clear packet statistics on VSIs.

Syntax

reset l2vpn statistics vsi [ name vsi-name ]

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Views

User view

Predefined user roles

network-admin

context-admin

Parameters

name vsi-name: Specifies a VSI by its name, a case-sensitive string of 1 to 31 characters. If you do not specify a VSI, this command clears packet statistics on all VSIs.

Examples

# Clear packet statistics on all VSIs.

<Sysname> reset l2vpn statistics vsi

Related commands

statistics enable (VSI view)

selective-flooding mac-address

Use selective-flooding mac-address to enable selective flood for a MAC address.

Use undo selective-flooding mac-address to disable selective flood for a MAC address.

Syntax

selective-flooding mac-address mac-address

undo selective-flooding mac-address mac-address

Default

Selective flood is disabled for all MAC addresses.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

mac-address: Specifies a MAC address. The MAC address cannot be all Fs.

Usage guidelines

This command excludes a remote MAC address from the flood suppression done by using the flooding disable command. The VTEP will flood the frames destined for the specified MAC address to remote sites when unknown-unicast floods are confined to the local site.

Examples

# Enable selective flood for 000f-e201-0101 on VSI vsi1.

<Sysname> system-view

[Sysname] vsi vsi1

[Sysname-vsi-vsi1] selective-flooding mac-address 000f-e201-0101

Related commands

flooding disable

service-class

Use service-class to set a service class value for outgoing VXLAN packets.

Use undo service-class to restore the default.

Syntax

service-class service-class-value

undo service-class

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

 

Default

No service class value is set for outgoing VXLAN packets.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

service-class-value: Specifies a service class value. The value range for this argument is 0 to 15.

Usage guidelines

Class Based Tunnel Selection (CBTS) compares the service class value of VXLAN packets with the service class values of MPLS TE tunnels. CBTS uses the following rules to select a tunnel to forward the traffic:

·     If the packets match only one MPLS TE tunnel, CBTS uses this tunnel.

·     If the packets match multiple MPLS TE tunnels, CBTS randomly selects one tunnel from them.

·     If the packets do not match any MPLS TE tunnel, CBTS selects the MPLS TE tunnel that meets the following requirements:

¡     Its service class value is smaller than the service class value of the traffic.

¡     Its service class value is the nearest to the service class value of the traffic.

If multiple qualified tunnels exist, CBTS randomly selects one of them to forward the packets. If an MPLS TE tunnel is not configured with a service class value, this tunnel has the smallest service class value.

The service class value is used only when MPLS TE tunnels are used to forward the VXLAN packets. This value is meaningless if any other tunnel is used to forward the VXLAN packets.

To set the service class value for an MPLS TE tunnel, use the mpls te service-class command. For more information about this command, see MPLS TE commands in MPLS Command Reference.

If you execute the service-class command multiple times for a VSI, the most recent configuration takes effect.

Examples

# Set the service class value to 2 for outgoing VXLAN packets.

<Sysname> system-view

[Sysname] vsi vpna

[Sysname-vsi-vpna] service-class 2

Related commands

display l2vpn vsi

service-instance

Use service-instance to create an Ethernet service instance and enter its view, or enter the view of an existing Ethernet service instance.

Use undo service-instance to delete an Ethernet service instance.

Syntax

service-instance instance-id

undo service-instance instance-id

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

No Ethernet service instances exist.

Views

Layer 2 aggregate interface view

Layer 2 Ethernet interface view

Predefined user roles

network-admin

context-admin

Parameters

instance-id: Specifies an Ethernet service instance ID in the range of 1 to 4096.

Examples

# On Layer 2 Ethernet interface GigabitEthernet 1/0/1, create Ethernet service instance 1 and enter Ethernet service instance view.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] service-instance 1

[Sysname-GigabitEthernet1/0/1-srv1]

Related commands

display l2vpn service-instance

shutdown

Use shutdown to shut down a VSI.

Use undo shutdown to bring up a VSI.

Syntax

shutdown

undo shutdown

Default

VSIs are not manually shut down.

Views

VSI view

Predefined user roles

network-admin

context-admin

Usage guidelines

Use this command to temporarily disable a VSI to provide Layer 2 switching services. The shutdown action does not change settings on the VSI. You can continue to configure the VSI. After you bring up the VSI again, the VSI provides services based on the latest settings.

Examples

# Shut down VSI vpn1.

<Sysname> system-view

[Sysname] vsi vpn1

[Sysname-vsi-vpn1] shutdown

Related commands

display l2vpn vsi

statistics enable (Ethernet service instance view)

Use statistics enable to enable packet statistics for an Ethernet service instance.

Use undo statistics enable to disable packet statistics for an Ethernet service instance.

Syntax

statistics enable

undo statistics enable

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The packet statistics feature is disabled for an Ethernet service instance.

Views

Ethernet service instance view

Predefined user roles

network-admin

context-admin

Usage guidelines

For this command to take effect, you must configure a frame match criterion for the Ethernet service instance and map it to a VSI. If you modify the frame match criterion or VSI mapping, packet statistics of the instance is cleared.

Examples

# Enable packet statistics for Ethernet service instance 200 on GigabitEthernet 1/0/1.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] service-instance 200

[Sysname-GigabitEthernet1/0/1-srv200] statistics enable

Related command

display l2vpn service-instance verbose

reset l2vpn statistics ac

statistics enable (VSI view)

Use statistics enable to enable packet statistics for a VSI.

Use undo statistics enable to disable packet statistics for a VSI.

Syntax

statistics enable

undo statistics enable

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The packet statistics feature is disabled for a VSI.

Views

VSI view

Predefined user roles

network-admin

context-admin

Examples

# Enable packet statistics for VSI vsi1.

<Sysname> system-view

[Sysname] vsi vsi1

[Sysname-vsi-vsi1] statistics enable

Related commands

display l2vpn vsi verbose

reset l2vpn statistics vsi

tunnel

Use tunnel to assign a VXLAN tunnel to a VXLAN.

Use undo tunnel to remove a VXLAN tunnel from a VXLAN.

Syntax

tunnel tunnel-number

undo tunnel tunnel-number

Default

A VXLAN does not contain VXLAN tunnels.

Views

VXLAN view

Predefined user roles

network-admin

context-admin

Parameters

tunnel-number: Specifies a tunnel interface number. The value range for this argument is 0 to 1023. The tunnel must be a VXLAN tunnel.

 

 

remote-vni vxlan-id: Specifies a remote VXLAN ID. The value range for the vxlan-id argument varies by device model. You can specify this option only for a VXLAN-DCI tunnel.

Usage guidelines

This command assigns a VXLAN tunnel to a VXLAN to provide Layer 2 connectivity for the VXLAN between two sites. In unicast mode, the system floods unknown unicast, multicast, and broadcast traffic to each tunnel in the VXLAN.

You can assign multiple VXLAN tunnels to a VXLAN, and configure a VXLAN tunnel to trunk multiple VXLANs.

Examples

# Assign VXLAN tunnels 1 and 2 to VXLAN 10000.

<Sysname> system-view

[Sysname] vsi vpna

[Sysname-vsi-vpna] vxlan 10000

[Sysname-vsi-vpna-vxlan-10000] tunnel 1

[Sysname-vsi-vpna-vxlan-10000] tunnel 2

Related commands

display vxlan tunnel

tunnel bfd enable

Use tunnel bfd enable to enable BFD on a VXLAN tunnel interface.

Use undo tunnel bfd enable to disable BFD on a VXLAN tunnel interface.

Syntax

tunnel bfd enable destination-mac mac-address

undo tunnel bfd enable

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

BFD is disabled on a VXLAN tunnel interface.

Views

VXLAN tunnel interface view

Predefined user roles

network-admin

context-admin

Parameters

destination-mac mac-address: Specifies a destination MAC address in H-H-H format for BFD control packets. The MAC address can be a remote VTEP address or a multicast address. You can omit the consecutive zeros at the beginning of each segment. For example, you can enter f-e2-1 for 000f-00e2-0001.

Usage guidelines

Enable BFD on both ends of a VXLAN tunnel for quick link connectivity detection. The VTEPs periodically send BFD single-hop control packets to each other through the VXLAN tunnel. A VTEP sets the tunnel state to Defect if it has not received control packets from the remote end for 5 seconds. In this situation, the tunnel interface state is still Up. The tunnel state will change from Defect to Up if the VTEP can receive BFD control packets again.

Examples

# Enable BFD on VXLAN tunnel interface Tunnel 9, and specify 1-1-1 as the destination MAC address for BFD control packets.

<Sysname> system-view

[Sysname] interface tunnel 9 mode vxlan

[Sysname-Tunnel9] tunnel bfd enable destination-mac 1-1-1

tunnel statistics enable

Use tunnel statistics enable to enable packet statistics for all VXLAN tunnels associated with a VSI.

Use undo tunnel statistics enable to disable packet statistics for all VXLAN tunnels associated with a VSI.

Syntax

tunnel statistics enable

undo tunnel statistics enable

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The packet statistics feature is disabled for the VXLAN tunnels associated with a VSI.

Views

VSI view

Predefined user roles

network-admin

context-admin

Usage guidelines

This command enables packet statistics only for VXLAN tunnels. It does not take effect on VXLAN-DCI tunnels.

Examples

# Enable packet statistics for all VXLAN tunnels associated with VSI vpna.

<Sysname> system-view

[Sysname] vsi vpna

[Sysname-vsi-vpna] tunnel statistics enable

Related commands

display vxlan tunnel

vsi

Use vsi to create a VSI and enter its view, or enter the view of an existing VSI.

Use undo vsi to delete a VSI.

Syntax

vsi vsi-name

undo vsi vsi-name

Default

No VSIs exist.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

vsi-name: Specifies a VSI name, a case-sensitive string of 1 to 31 characters.

Usage guidelines

A VSI acts as a virtual switch to provide Layer 2 switching services for a VXLAN on a VTEP. A VSI has all functions of a physical Ethernet switch, including source MAC address learning, MAC address aging, and flooding.

A VSI can provide services only for one VXLAN.

Examples

# Create VSI vxlan10 and enter VSI view.

<Sysname> system-view

[Sysname] vsi vxlan10

[Sysname-vsi-vxlan10]

Related commands

display l2vpn vsi

vxlan

Use vxlan to create a VXLAN and enter its view, or enter the view of an existing VXLAN.

Use undo vxlan to restore the default.

Syntax

vxlan vxlan-id

undo vxlan

Default

No VXLANs exist.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

vxlan-id: Specifies a VXLAN ID in the range of 0 to 16777215.

Usage guidelines

You can create only one VXLAN for a VSI. The VXLAN ID for each VSI must be unique.

Examples

# Create VXLAN 10000 for VSI vpna and enter VXLAN view.

<Sysname> system-view

[Sysname] vsi vpna

[Sysname-vsi-vpna] vxlan 10000

[Sysname-vsi-vpna-vxlan-10000]

Related commands

vsi

vxlan fast-forwarding enable

Use vxlan fast-forwarding enable to enable VXLAN fast forwarding.

Use undo vxlan fast-forwarding enable to disable VXLAN fast forwarding.

Syntax

vxlan fast-forwarding enable

undo vxlan fast-forwarding enable

Default

VXLAN fast forwarding is disabled.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

VXLAN fast forwarding enables the device to bypass QoS and security services when the device forwards data traffic over VXLAN tunnels based on the software. As a best practice, enable this feature to improve forwarding speed only when QoS and security services are not configured on the following interfaces:

·     VSI interfaces.

·     Traffic outgoing interfaces for VXLAN tunnels.

When VXLAN fast forwarding is enabled, a VXLAN tunnel cannot use ECMP routes to load share traffic. Instead, it selects one route from the ECMP routes to forward VXLAN packets.

Examples

# Enable VXLAN fast forwarding.

<Sysname> system

[Sysname] vxlan fast-forwarding enable

vxlan invalid-udp-checksum discard

Use vxlan invalid-udp-checksum discard to enable the device to drop the VXLAN packets that fail UDP checksum check.

Use undo vxlan invalid-udp-checksum discard to restore the default.

Syntax

vxlan invalid-udp-checksum discard

undo vxlan invalid-udp-checksum discard

Default

The device does not check the UDP checksum of VXLAN packets.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

This command enables the device to check the UDP checksum of VXLAN packets.

The device always sets the UDP checksum of VXLAN packets to 0. For compatibility with third-party devices, a VXLAN packet can pass the check if its UDP checksum is 0 or correct. If its UDP checksum is incorrect, the VXLAN packet fails the check and is dropped.

Examples

# Enable the device to drop the VXLAN packets that fail UDP checksum check.

<Sysname> system-view

[Sysname] vxlan invalid-udp-checksum discard

vxlan ip-forwarding

Use vxlan ip-forwarding to enable Layer 3 forwarding for all VXLANs.

Use undo vxlan ip-forwarding to enable Layer 2 forwarding for all VXLANs.

Syntax

vxlan ip-forwarding

undo vxlan ip-forwarding

The following compatibility matrixes show the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

Layer 3 forwarding is enabled for all VXLANs.

Views.

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

If the device is a VTEP, enable Layer 2 forwarding for VXLANs. If the device is a VXLAN IP gateway, enable Layer 3 forwarding for VXLANs.

In Layer 3 forwarding mode, the VTEP uses the ARP table (IPv4 network) or ND table (IPv6 network) to forward traffic for VXLANs. In Layer 2 forwarding mode, the VTEP uses the MAC address table to forward traffic for VXLANs.

You must delete all VSIs, VSI interfaces, and VXLAN tunnel interfaces before you can change the forwarding mode.

Examples

# Enable Layer 3 forwarding for all VXLANs.

<Sysname>system-view

[Sysname] vxlan ip-forwarding

vxlan local-mac report

Use vxlan local-mac report to enable local-MAC logging.

Use undo vxlan local-mac report to disable local-MAC logging.

Syntax

vxlan local-mac report

undo vxlan local-mac report

Default

Local-MAC logging is disabled.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

When the local-MAC logging feature is enabled, the VXLAN module immediately sends a log message with its local MAC addresses to the information center. When a local MAC address is added or removed, a log message is also sent to the information center to notify the local-MAC change.

With the information center, you can set log message filtering and output rules, including output destinations. For more information about configuring the information center, see Network Management and Monitoring Configuration Guide.

Examples

# Enable local-MAC logging.

<Sysname> system-view

[Sysname] vxlan local-mac report

vxlan source udp-port acl

Use vxlan source udp-port acl to configure an ACL match criterion and specify the source UDP port number in the VXLAN encapsulation for matching frames.

Use undo vxlan source udp-port to restore the default.

Syntax

vxlan source udp-port port-number acl acl-number

undo vxlan source udp-port

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The source UDP port number in the VXLAN encapsulation is generated based on the source and destination MAC addresses of the inner Ethernet frame.

Views

VXLAN tunnel interface view

Predefined user roles

network-admin

context-admin

Parameters

port-number: Specifies a UDP port number in the range of 1024 to 65535. As a best practice, specify a port number in the range of 1024 to 49151.

acl-number: Specifies an ACL by its number in the range of 3000 to 3999. The ACL must be an advanced ACL.

Usage guidelines

This command takes effect only on IPv4-based VXLAN. Only manually created VXLAN tunnel interfaces support this command.

This command enables a VXLAN tunnel interface to filter frames by using an ACL and encapsulate a specific source UDP port number for matching frames. This allows IPsec to identify the VXLAN packets to encrypt by the source UDP port number in the VXLAN encapsulation.

If the ACL specified by using this command does not exist or does not contain an IP address-related rule, frames are encapsulated based on the default setting.

This command has a higher priority than the vxlan source udp-port five-tuple command.

If you execute this command multiple times, the most recent configuration takes effect.

Examples

# Configure VXLAN tunnel interface Tunnel 1 to encapsulate source UDP port number 50001 for the frames that match ACL 3001.

<Sysname> system-view

[Sysname] interface tunnel 1 mode vxlan

[Sysname-Tunnel1] vxlan source udp-port 50001 acl 3001

Related commands

acl (ACL and QoS Command Reference)

vxlan source udp-port five-tuple

vxlan source udp-port five-tuple

Use vxlan source udp-port five-tuple to configure a VXLAN tunnel interface to generate the source UDP port number in the VXLAN encapsulation based on the IP five-tuple of the inner Ethernet frame.

Use undo vxlan source udp-port five-tuple to restore the default.

Syntax

vxlan source udp-port five-tuple

undo vxlan source udp-port five-tuple

The following compatibility matrix shows the support of hardware platforms for this command:

 

F1000 series

Models

Command compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

Yes

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160

Yes

F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI, F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG

Yes

F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

Command compatibility

F100-X-G5 series

F100-E-G5

Yes

F100-A-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3

Yes

F100-C-G3, F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2

Yes

F100-C-G2, F100-M-G2, F100-S-G2

No

F100-WiNet series

F100-A81-WiNet, F100-A80-WiNet, F100-A91-WiNet

Yes

F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1

No

F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

Yes

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-E-EI

Yes

F100-C-EI, F100-C-HI, F100-C-XI, F100-S-HI, F100-S-XI

No

Default

The source UDP port number in the VXLAN encapsulation is generated based on the source and destination MAC addresses of the inner Ethernet frame.

Views

VXLAN tunnel interface view

Predefined user roles

network-admin

context-admin

Usage guidelines

This command takes effect only on IPv4-based VXLAN. Only manually created VXLAN tunnel interfaces support this command.

This command has a lower priority than the vxlan source udp-port acl command. If you use both commands on a VXLAN tunnel interface, the vxlan source udp-port five-tuple command takes effect only on the frames that fail to match the ACL specified by using the vxlan source udp-port acl command.

Examples

# Configure VXLAN tunnel interface Tunnel 1 to generate the source UDP port number in the VXLAN encapsulation based on the IP five-tuple of the inner Ethernet frame.

<Sysname> system-view

[Sysname] interface tunnel 1 mode vxlan

[Sysname-Tunnel1] vxlan source udp-port five-tuple

Related commands

vxlan source udp-port acl

vxlan tunnel mac-learning disable

Use vxlan tunnel mac-learning disable to disable remote-MAC address learning.

Use undo vxlan tunnel mac-learning disable to enable remote-MAC address learning.

Syntax

vxlan tunnel mac-learning disable

undo vxlan tunnel mac-learning disable

Default

Remote-MAC address learning is enabled.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

When network attacks occur, use this command to prevent the device from learning incorrect remote MAC addresses in the data plane.

Examples

# Disable remote-MAC address learning.

<Sysname> system-view

[Sysname] vxlan tunnel mac-learning disable

vxlan udp-port

Use vxlan udp-port to set the destination UDP port number for VXLAN packets.

Use undo vxlan udp-port to restore the default.

Syntax

vxlan udp-port port-number

undo vxlan udp-port

Default

The destination UDP port number is 4789 for VXLAN packets.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

port-number: Specifies a UDP port number in the range of 1 to 65535. As a best practice, specify a port number in the range of 1024 to 65535 to avoid conflict with well-known ports.

Usage guidelines

You must configure the same destination UDP port number on all VTEPs in a VXLAN.

Examples

# Set the destination UDP port number to 6666 for VXLAN packets.

<Sysname> system-view

[Sysname] vxlan udp-port 6666

xconnect vsi

Use xconnect vsi to map an AC to a VSI.

Use undo xconnect vsi to restore the default.

Syntax

xconnect vsi vsi-name [ track track-entry-number&<1-3> ]

undo xconnect vsi

Default

An AC is not mapped to any VSI.

Views

Interface view

Predefined user roles

network-admin

context-admin

Parameters

vsi-name: Specifies the VSI name, a case-sensitive string of 1 to 31 characters.

track track-entry-number&<1-3>: Specifies a space-separated list of up to three track entry numbers in the range of 1 to 1024. The AC is up only if a minimum of one associated track entry is in positive state.

Usage guidelines

For traffic that matches a Layer 3 interface, the system uses the VSI's MAC address table to make a forwarding decision.

Examples

# Map GigabitEthernet 1/0/1 to VSI vpn1.

<Sysname> system-view

[Sysname] vsi vpn1

[Sysname-vsi-vpn1] quit

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] xconnect vsi vpn1

Related commands

display l2vpn interface

vsi

VXLAN IP gateway commands

arp distributed-gateway dynamic-entry synchronize

Use arp distributed-gateway dynamic-entry synchronize to enable dynamic ARP entry synchronization for distributed VXLAN IP gateways.

Use undo arp distributed-gateway dynamic-entry synchronize to disable dynamic ARP entry synchronization for distributed VXLAN IP gateways.

Syntax

arp distributed-gateway dynamic-entry synchronize

undo arp distributed-gateway dynamic-entry synchronize

Default

Dynamic ARP entry synchronization is disabled for distributed VXLAN IP gateways.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

When local proxy ARP is enabled on distributed VXLAN IP gateways, each gateway learns ARP information independently. A gateway does not forward ARP packets destined for its local VSI interfaces to other gateways. For distributed VXLAN IP gateways to have the same ARP entries, you must enable dynamic ARP entry synchronization.

A controller can also synchronize ARP entries among distributed VXLAN IP gateways. When you use a controller, do not enable dynamic ARP entry synchronization.

Examples

# Enable dynamic ARP entry synchronization for distributed VXLAN IP gateways.

<Sysname> system-view

[Sysname] arp distributed-gateway dynamic-entry synchronize

Related commands

distributed-gateway local

local-proxy-arp enable (Layer 3—IP Services Command Reference)

bandwidth

Use bandwidth to set the expected bandwidth for a VSI interface.

Use undo bandwidth to restore the default.

Syntax

bandwidth bandwidth-value

undo bandwidth

Default

The expected bandwidth (in kbps) equals the interface baudrate divided by 1000.

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Parameters

bandwidth-value: Specifies the expected bandwidth, in the range of 1 to 400000000 kbps.

Usage guidelines

The expected bandwidth is an informational parameter used only by higher-layer protocols for calculation. You cannot adjust the actual bandwidth of an interface by using this command.

Examples

# Set the expected bandwidth to 10000 kbps for VSI-interface 100.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] bandwidth 10000

default

Use default to restore the default settings for a VSI interface.

Syntax

default

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Usage guidelines

CAUTION

CAUTION:

The default command might interrupt ongoing network services. Make sure you are fully aware of the impact of this command when you use it on a live network.

 

This command might fail to restore the default settings for some commands for reasons such as command dependencies and system restrictions.

To resolve this problem:

1.     Use the display this command in interface view to identify these commands.

2.     Use their undo forms or follow the command reference to restore their default settings.

3.     If the restoration attempt still fails, follow the error message instructions to resolve the problem.

Examples

# Restore the default settings for VSI-interface 100.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] default

This command will restore the default settings. Continue? [Y/N]:y

description

Use description to configure the description of a VSI interface.

Use undo description to restore the default.

Syntax

description text

undo description

Default

The description of a VSI interface is interface-name plus Interface (for example, Vsi-interface100 Interface).

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Parameters

text: Specifies a description, a case-sensitive string of 1 to 255 characters.

Examples

# Configure the description as gateway for VXLAN 10 for VSI-interface 100.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] description gateway for VXLAN 10

display interface vsi-interface

Use display interface vsi-interface to display information about VSI interfaces.

Syntax

display interface [ vsi-interface [ vsi-interface-id ] ] [ brief [ description | down ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

context-admin

context-operator

Parameters

vsi-interface [ vsi-interface-id ]: Specifies a VSI interface by its number. Make sure the specified VSI interface has been created on the device. If you do not specify the vsi-interface [ vsi-interface-id ] option, this command displays information about all interfaces. If you specify only the vsi-interface keyword, this command displays information about all VSI interfaces. If you specify a VSI interface, this command displays information about the specified interface.

brief: Display brief interface information. If you do not specify this keyword, the command displays detailed interface information.

description: Displays complete interface descriptions. If you do not specify this keyword, the command displays only the first 27 characters of interface descriptions.

down: Displays interfaces that are physically down as well as the down reason. If you do not specify this keyword, the command does not filter output by physical interface state.

Examples

# Display information about VSI-interface 100.

<Sysname> display interface vsi-interface 100

Vsi-interface100

Current state: UP

Line protocol state: UP

Description: Vsi-interface100 Interface

Bandwidth: 1000000 kbps

Maximum transmission unit: 1500

Internet address: 10.1.1.1/24 (primary)

IP packet frame type: Ethernet II, hardware address: 0011-2200-0102

IPv6 packet frame type: Ethernet II, hardware address: 0011-2200-0102

Physical: Unknown, baudrate: 1000000 kbps

Last clearing of counters: Never

Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Last 300 seconds output rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Input: 0 packets, 0 bytes, 0 drops

Output: 0 packets, 0 bytes, 0 drops

Table 10 Command output

Field

Description

Current state

Physical link state of the interface:

·     Administratively DOWN—The interface has been shut down by using the shutdown command.

·     DOWN—The interface is administratively up, but its physical state is down.

·     UP—The interface is both administratively and physically up.

Line protocol state

Data link layer state of the interface:

·     UP—The data link layer protocol is up.

·     UP(spoofing)—The data link layer protocol is up, but the link is an on-demand link or does not exist.

·     DOWN—The data link layer protocol is down.

Description

Description of the interface.

Bandwidth

Expected bandwidth of the interface.

Maximum transmission unit

MTU of the interface.

Internet protocol processing: Disabled

The interface is not assigned an IP address and cannot process IP packets.

Internet address: ip-address/mask-length (Type)

IP address of the interface and type of the address in parentheses.

Possible IP address types include:

·     Primary—Manually configured primary IP address.

·     Sub—Manually configured secondary IP address. If the interface has both primary and secondary IP addresses, the primary IP address is displayed. If the interface has only secondary IP addresses, the lowest secondary IP address is displayed.

·     DHCP-allocated—DHCP allocated IP address. For more information, see DHCP client configuration in Layer 3IP Services Configuration Guide.

·     BOOTP-allocatedBOOTP allocated IP address. For more information, see BOOTP client configuration in Layer 3IP Services Configuration Guide.

·     PPP-negotiated—IP address assigned by a PPP server during PPP negotiation. For more information, see PPP configuration in PPP and PPPoE Configuration Guide.

·     Unnumbered—IP address borrowed from another interface.

·     MAD—IP address assigned to an IRF member device for MAD on the interface. For more information, see IRF configuration in Virtual Technologies Configuration Guide.

IP packet frame type

IPv4 packet framing format.

hardware address

MAC address.

IPv6 packet frame type

IPv6 packet framing format.

Physical

Physical type of the interface, which is fixed at Unknown.

baudrate

Interface baudrate in kbps.

Last clearing of counters

Last time when the reset counters interface vsi-interface command was used to clear interface statistics.

This field displays Never if the reset counters interface vsi-interface command has never been used on the interface since the device startup.

Last 300 seconds input rate

Average input rate for the last 300 seconds.

Last 300 seconds output rate

Average output rate for the last 300 seconds.

Input: 0 packets, 0 bytes, 0 drops

Incoming traffic statistics on the interface:

·     Number of incoming packets.

·     Number of incoming bytes.

·     Number of dropped incoming packets.

Output: 0 packets, 0 bytes, 0 drops

Outgoing traffic statistics on the interface:

·     Number of outgoing packets.

·     Number of outgoing bytes.

·     Number of dropped outgoing packets.

 

# Display brief information about all VSI interfaces.

<Sysname> display interface vsi-interface brief

Brief information on interfaces in route mode:

Link: ADM - administratively down; Stby - standby

Protocol: (s) - spoofing

Interface            Link Protocol Primary IP      Description

Vsi100               DOWN DOWN     --

# Display brief information and complete description for VSI-interface 100.

<Sysname> display interface vsi-interface 100 brief description

Brief information on interfaces in route mode:

Link: ADM - administratively down; Stby - standby

Protocol: (s) - spoofing

Interface            Link Protocol Primary IP      Description

Vsi100               UP    UP      1.1.1.1         VSI-interface100

# Displays interfaces that are physically down and the down reason.

<Sysname> display interface brief down

Brief information on interfaces in route mode:

Link: ADM - administratively down; Stby - standby

Interface            Link   Cause

Vsi100               DOWN   Administratively

Vsi200               DOWN   Administratively

Table 11 Command output

Field

Description

Interface

Abbreviated interface name.

Link

Physical link state of the interface:

·     UP—The interface is physically up.

·     DOWN—The interface is physically down.

·     ADM—The interface has been shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command.

·     Stby—The interface is a backup interface in standby state. To see the primary interface, use the display interface-backup state command.

Protocol

Data link layer protocol state of the interface:

·     UP—The data link layer protocol of the interface is up.

·     UP (s)—The data link layer protocol of the interface is up, but the link is an on-demand link or does not exist. The (s) attribute represents the spoofing flag.

·     DOWN—The data link layer protocol of the interface is down.

Primary IP

Primary IP address of the interface. This field displays two hyphens (--) if the interface does not have an IP address.

Description

Description of the interface.

Cause

Cause for the physical link state of an interface to be DOWN:

·     Administratively—The interface has been manually shut down by using the shutdown command. To restore the physical state of the interface, use the undo shutdown command.

·     Not connected—The interface is not mapped to any VSI, or the mapped VSI does not have any AC or VXLAN tunnel.

 

Related commands

reset counters interface vsi-interface

distributed-gateway local

Use distributed-gateway local to specify a VSI interface as a distributed gateway to provide services for the local site.

Use undo distributed-gateway local to restore the default.

Syntax

distributed-gateway local

undo distributed-gateway local

Default

A VSI interface is not a distributed gateway.

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Usage guidelines

If a VXLAN uses distributed gateway services, you must assign the same IP address to the VXLAN's VSI interfaces on different VTEPs. To avoid IP address conflicts, you must specify the VSI interface on each VTEP as a distributed gateway.

Examples

# Specify VSI-interface 100 as a distributed gateway.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] distributed-gateway local

gateway subnet

Use gateway subnet to assign a subnet to a VSI.

Use undo gateway subnet to remove a subnet from a VSI.

Syntax

gateway subnet { ipv4-address wildcard-mask | ipv6-address prefix-length }

undo gateway subnet { ipv4-address wildcard-mask | ipv6-address prefix-length }

Default

No subnet is assigned to a VSI.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

ipv4-address: Specifies an IPv4 subnet address in dotted-decimal notation.

wildcard-mask: Specifies a wildcard mask in dotted decimal notation. In contrast to a network mask, the 0 bits in a wildcard mask represent "do care" bits, and the 1 bits represent "don't care" bits. If the "do care" bits in a packet's IP address are identical to the "do care" bits in the specified subnet address, the packet is assigned to the VSI. All "don't care" bits are ignored. The 0s and 1s in a wildcard mask can be noncontiguous. For example, 0.255.0.255 is a valid wildcard mask.

ipv6-address prefix-length: Specifies an IPv6 subnet address and the address prefix length in the range of 1 to 128.

Usage guidelines

You must configure this command on VSIs that share a gateway interface. This command enables the VSI interface to identify the VSI of a packet.

You can assign a maximum of eight IPv4 and IPv6 subnets to a VSI.

You must specify a gateway interface for a VSI before you can assign subnets to the VSI. If you remove the gateway interface from the VSI, the VSI's subnet settings are automatically deleted.

For VSIs that share a gateway interface, the subnets must be unique.

Examples

# Assign subnet 100.0.10.0/24 to VSI vxlan.

<Sysname> system-view

[Sysname] vsi vxlan

[Sysname-vsi-vxlan] gateway subnet 100.0.10.0 0.0.0.255

gateway vsi-interface

Use gateway vsi-interface to specify a gateway interface for a VSI.

Use undo gateway vsi-interface to restore the default.

Syntax

gateway vsi-interface vsi-interface-id

undo gateway vsi-interface

Default

No gateway interface is specified for a VSI.

Views

VSI view

Predefined user roles

network-admin

context-admin

Parameters

vsi-interface-id: Specifies a VSI interface by its number. The value range for this argument is 0 to 8191.

Usage guidelines

A VSI can have only one gateway interface. Multiple VSIs can share a gateway interface.

Examples

# Specify VSI-interface 100 as the gateway interface for VSI vpna.

<Sysname> system-view

[Sysname] vsi vpna

[Sysname-vsi-vpna] gateway vsi-interface 100

Related commands

interface vsi-interface

interface vsi-interface

Use interface vsi-interface to create a VSI interface and enter its view, or enter the view of an existing VSI interface.

Use undo interface vsi-interface to delete a VSI interface.

Syntax

interface vsi-interface vsi-interface-id

undo interface vsi-interface vsi-interface-id

Default

No VSI interfaces exist.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

vsi-interface-id: Specifies a VSI interface number. The value range for this argument is 0 to 8191.

Examples

# Create VSI-interface 100 and enter VSI interface view.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100]

Related commands

gateway vsi-interface

mac-address

Use mac-address to assign a MAC address to a VSI interface.

Use undo mac-address to restore the default.

Syntax

mac-address mac-address

undo mac-address

Default

A VSI interface does not have a MAC address.

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Parameters

mac-address: Specifies a MAC address in H-H-H format.

Examples

# Assign MAC address 0001-0001-0001 to VSI-interface 100.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] mac-address 1-1-1

mtu

Use mtu to set the MTU for a VSI interface.

Use undo mtu to restore the default.

Syntax

mtu size

undo mtu

Default

The MTU is 1500 bytes.

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Parameters

size: Specifies an MTU value in the range of 46 to 1500 bytes.

Examples

# Set the MTU to 1430 bytes for VSI-interface 100.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] mtu 1430

reset counters interface vsi-interface

Use reset counters interface vsi-interface to clear packet statistics on VSI interfaces.

Syntax

reset counters interface [ vsi-interface [ vsi-interface-id ] ]

Views

User view

Predefined user roles

network-admin

context-admin

Parameters

vsi-interface [ vsi-interface-id ]: Specifies a VSI interface by its number. Make sure the specified VSI interface has been created on the device. If you do not specify the vsi-interface [ vsi-interface-id ] option, this command clears packet statistics on all interfaces. If you specify only the vsi-interface keyword, this command clears packet statistics on all VSI interfaces. If you specify a VSI interface, this command clears packet statistics on the specified interface.

Usage guidelines

Use this command to clear history statistics before you collect traffic statistics for a time period.

Examples

# Clear packet statistics on VSI-interface 100.

<Sysname> reset counters interface vsi-interface 100

Related commands

display interface vsi-interface

shutdown

Use shutdown to shut down a VSI interface.

Use undo shutdown to bring up a VSI interface.

Syntax

shutdown

undo shutdown

Default

A VSI interface is not manually shut down.

Views

VSI interface view

Predefined user roles

network-admin

context-admin

Usage guidelines

CAUTION

CAUTION:

If you shut down a VSI interface, the VXLAN network using this VSI interface as the gateway will be unable to communicate with other networks at Layer 3. Make sure you are fully aware of the impact of this command when you use it on a live network.

 

Examples

# Shut down VSI-interface 100.

<Sysname> system-view

[Sysname] interface vsi-interface 100

[Sysname-Vsi-interface100] shutdown

vtep group member local

Use vtep group member local to assign the local VTEP to a VTEP group.

Use undo vtep group member local to remove the local VTEP from a VTEP group.

Syntax

vtep group group-ip member local member-ip

undo vtep group group-ip member local

Default

A VTEP is not assigned to any VTEP group.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

group-ip: Specifies a VTEP group by its group IP address. The IP address must already exist on the local VTEP.

member-ip: Specifies the member VTEP IP address for the local VTEP. The IP address must already exist on the local VTEP.

Usage guidelines

Member VTEPs in a VTEP group cannot use the group IP address or share an IP address.

Examples

# Assign the local VTEP to VTEP group 1.1.1.1, and specify 2.2.2.2 as the member VTEP IP address of the local VTEP.

<Sysname> system-view

[Sysname] vtep group 1.1.1.1 member local 2.2.2.2

Related commands

vtep group member remote

vtep group member remote

Use vtep group member remote to specify a VTEP group and its member VTEPs.

Use undo vtep group member remote to remove a VTEP group and its member VTEPs.

Syntax

vtep group group-ip member remote member-ip&<1-8>

undo vtep group group-ip member remote

Default

No VTEP group is specified.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

group-ip: Specifies a VTEP group by its group IP address.

member-ip&<1-8>: Specifies a space-separated list of up to eight member VTEP IP addresses.

Examples

# Specify VTEP group 1.1.1.1 and its member VTEPs at 2.2.2.2, 3.3.3.3, and 4.4.4.4.

<Sysname> system-view

[Sysname] vtep group 1.1.1.1 member remote 2.2.2.2 3.3.3.3 4.4.4.4

Related commands

vtep group member local

vxlan tunnel arp-learning disable

Use vxlan tunnel arp-learning disable to disable remote ARP learning for VXLANs.

Use undo vxlan tunnel arp-learning disable to enable remote ARP learning for VXLANs.

Syntax

vxlan tunnel arp-learning disable

undo vxlan tunnel arp-learning disable

Default

Remote ARP learning is enabled for VXLANs.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

By default, the device learns ARP information of remote VMs from packets received on VXLAN tunnel interfaces. To save resources on VTEPs in an SDN transport network, you can temporarily disable remote ARP learning when the controller and VTEPs are synchronizing entries. After the entry synchronization is completed, use the undo vxlan tunnel arp-learning disable command to enable remote ARP learning.

As a best practice, disable remote ARP learning for VXLANs only when the controller and VTEPs are synchronizing entries.

Examples

# Disable remote ARP learning for VXLANs.

<Sysname> system

[Sysname] vxlan tunnel arp-learning disable

OVSDB commands

The following compatibility matrixes show the support of hardware platforms for OVSDB commands:

 

F1000 series

Models

OVSDB compatibility

F1000-X-G5 series

F1000-A-G5, F1000-C-G5, F1000-C-G5-LI, F1000-E-G5, F1000-H-G5, F1000-S-G5

Yes

F1000-X-G3 series

F1000-A-G3, F1000-C-G3, F1000-E-G3, F1000-S-G3

Yes

F1000-X-G2 series

F1000-A-G2, F1000-C-G2, F1000-E-G2, F1000-S-G2

No

F1000-9X0-AI series

F1000-9390-AI, F1000-9385-AI, F1000-9380-AI, F1000-9370-AI, F1000-9360-AI, F1000-9350-AI, F1000-9330-AI, F1000-9320-AI

Yes

F1000-990-AI, F1000-980-AI, F1000-970-AI, F1000-960-AI, F1000-950-AI, F1000-930-AI, F1000-920-AI, F1000-910-AI, F1000-905-AI

No

F1000-C83X0 series

F1000-C8395, F1000-C8390, F1000-C8385, F1000-C8380, F1000-C8370, F1000-C8360, F1000-C8350, F1000-C8330

Yes

F1000-C81X0 series

F1000-C8180, F1000-C8170, F1000-C8160, F1000-C8150, F1000-C8130, F1000-C8120, F1000-C8110

No

F1000-7X0-HI series

F1000-770-HI, F1000-750-HI, F1000-740-HI, F1000-730-HI

Yes

F1000-720-HI, F1000-710-HI

No

F1000-C-X series

F1000-C-EI, F1000-C-HI

No

F1000-C-XI, F1000-E-XI

Yes

F1000-V series

F1000-E-VG, F1000-S-VG

No

SecBlade IV

LSPM6FWD8, LSQM2FWDSC8

No

 

F100 series

Models

OVSDB compatibility

F100-X-G5 series

F100-A-G5, F100-E-G5, F100-C-G5, F100-M-G5, F100-S-G5

No

F100-X-G3 series

F100-A-G3, F100-E-G3, F100-C-G3F100-M-G3, F100-S-G3

No

F100-X-G2 series

F100-A-G2, F100-E-G2, F100-C-G2, F100-M-G2, F100-S-G2

No

F100- WiNet series

F100-A80-WiNet, F100-C80-WiNet, F100-C60-WiNet, F100-C50-WiNet, F100-S80-WiNet

No

F100-A81-WiNet, F100-A91-WiNet

Yes

F100-C-A series

F100-C-A6, F100-C-A5, F100-C-A3, F100-C-A2, F100-C-A1, F100-C-A6-WL, F100-C-A5-W, F100-C-A3-W

No

F100-X-XI series

F100-A-EI, F100-A-HI, F100-A-SI, F100-C-EI, F100-C-HI, F100-C-XI, F100-E-EI, F100-S-HI, F100-S-XI

No

 

ovsdb server bootstrap ca-certificate

Use ovsdb server bootstrap ca-certificate to specify a CA certificate file for establishing OVSDB SSL connections.

Use undo ovsdb server bootstrap ca-certificate to restore the default.

Syntax

ovsdb server bootstrap ca-certificate ca-filename

undo ovsdb server bootstrap ca-certificate

Default

SSL uses the CA certificate file in the PKI domain.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

ca-filename: Specifies the CA certificate file name, a case-insensitive string. The file name cannot contain the slot string, and the file must be stored on the active MPU.

Usage guidelines

For the specified certificate to take effect, you must execute the ovsdb server enable command to enable the OVSDB server. You must disable and then re-enable the OVSDB server if it has been enabled.

If the specified CA certificate file does not exist, the device obtains a self-signed certificate from the controller. The obtained file uses the name specified for the ca-filename argument.

Examples

# Specify CA certificate file ca-new for establishing OVSDB SSL connections.

<Sysname> system-view

[Sysname] ovsdb server bootstrap ca-certificate ca-new

Related commands

ovsdb server enable

ovsdb server pki domain

ovsdb server pssl

ovsdb server ssl

ovsdb server enable

Use ovsdb server enable to enable the OVSDB server.

Use undo ovsdb server enable to disable the OVSDB server.

Syntax

ovsdb server enable

undo ovsdb server enable

Default

The OVSDB server is disabled.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

To obtain configuration data from controllers, you must enable the OVSDB server.

Before you enable the OVSDB server, you must establish an OVSDB SSL or TCP connection with a minimum of one controller.

Examples

# Enable the OVSDB server.

<Sysname> system-view

[Sysname] ovsdb server enable

ovsdb server pki domain

Use ovsdb server pki domain to specify a PKI domain for establishing OVSDB SSL connections.

Use undo ovsdb bootstrap server pki domain to restore the default.

Syntax

ovsdb server pki domain domain-name

undo ovsdb server pki domain

Default

No PKI domain is specified for establishing OVSDB SSL connections.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

domain-name: Specifies a PKI domain name, a case-sensitive string of 1 to 31 characters. The PKI domain must already exist and contain a complete certificate and key.

Usage guidelines

To communicate with controllers through SSL, you must specify a PKI domain.

For the specified PKI domain to take effect, you must execute the ovsdb server enable command to enable the OVSDB server. You must disable and then re-enable the OVSDB server if it has been enabled.

For more information about PKI domains, see PKI in Security Configuration Guide.

Examples

# Specify PKI domain ovsdb_test for establishing OVSDB SSL connections.

<Sysname> system-view

[Sysname] ovsdb server pki domain ovsdb_test

Related commands

ovsdb server bootstrap ca-certificate

ovsdb server enable

ovsdb server pssl

ovsdb server ssl

ovsdb server pssl

Use ovsdb server pssl to enable the device to listen for OVSDB SSL connection requests.

Use undo ovsdb server pssl to restore the default.

Syntax

ovsdb server pssl [ port port-number ]

undo ovsdb server pssl

Default

The device does not listen for OVSDB SSL connection requests.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

port port-number: Specifies a port to listen for OVSDB SSL connection requests. The value range for the port-number argument is 1 to 65535. If you do not specify a port, the device uses the port number 6640.

Usage guidelines

Before you use this command, you must specify a PKI domain for SSL.

You can specify only one port to listen for OVSDB SSL connection requests. If you execute this command multiple times, the most recent configuration takes effect.

For the specified port setting to take effect, you must execute the ovsdb server enable command to enable the OVSDB server. You must disable and then re-enable the OVSDB server if it has been enabled.

Examples

# Enable the device to listen for OVSDB SSL connection requests on port 6640.

<Sysname> system-view

[Sysname] ovsdb server pssl

Related commands

ovsdb server bootstrap ca-certificate

ovsdb server enable

ovsdb server pki domain

ovsdb server ssl

ovsdb server ptcp

Use ovsdb server ptcp to enable the device to listen for OVSDB TCP connection requests.

Use undo ovsdb server ptcp to restore the default.

Syntax

ovsdb server ptcp [ port port-number ]

undo ovsdb server ptcp

Default

The device does not listen for OVSDB TCP connection requests.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

port-number: Specifies a port to listen for OVSDB TCP connection requests. The value range for the port-number argument is 1 to 65535. If you do not specify a port, the device uses the port number 6640.

Usage guidelines

You can specify only one port to listen for OVSDB TCP connection requests. If you execute this command multiple times, the most recent configuration takes effect.

For the specified port setting to take effect, you must execute the ovsdb server enable command to enable the OVSDB server. You must disable and then re-enable the OVSDB server if it has been enabled.

Examples

# Enable the device to listen for OVSDB TCP connection requests on port 6640.

<Sysname> system-view

[Sysname] ovsdb server ptcp

Related commands

ovsdb server enable

ovsdb server tcp

ovsdb server ssl

Use ovsdb server ssl to set up an active OVSDB SSL connection to a controller.

Use undo ovsdb server ssl to remove an OVSDB SSL connection from a controller.

Syntax

ovsdb server ssl ip ip-address port port-number

undo ovsdb server ssl ip ip-address port port-number

Default

The device does not have active OVSDB SSL connections to a controller.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

ip ip-address: Specifies the destination IP address for the SSL connection.

port port-number: Specifies the destination port for the SSL connection. The value range for the port-number argument is 1 to 65535.

Usage guidelines

Before you use this command, you must specify a PKI domain for SSL.

The device can have a maximum of eight active SSL connections.

To establish the connection, you must execute the ovsdb server enable command. You must disable and then re-enable the OVSDB server if it has been enabled.

Examples

# Set up an active SSL connection to port 6632 at 192.168.12.2.

<Sysname> system-view

[Sysname] ovsdb server ssl ip 192.168.12.2 port 6632

Related commands

ovsdb server bootstrap ca-certificate

ovsdb server enable

ovsdb server pki domain

ovsdb server pssl

ovsdb server tcp

Use ovsdb server tcp to set up an active OVSDB TCP connection to a controller.

Use undo ovsdb server tcp to remove an OVSDB TCP connection.

Syntax

ovsdb server tcp ip ip-address port port-number

undo ovsdb server tcp ip ip-address port port-number

Default

The device does not have active OVSDB TCP connections.

Views

System view

Predefined user roles

network-admin

context-admin

Parameters

ip ip-address: Specifies the destination IP address for the TCP connection.

port port-number: Specifies the destination port for the TCP connection. The value range for the port-number argument is 1 to 65535.

Usage guidelines

The device can have a maximum of eight active OVSDB TCP connections.

To establish the connection, you must execute the ovsdb server enable command. You must disable and then re-enable the OVSDB server if it has been enabled.

Examples

# Set up an active OVSDB TCP connection to port 6632 at 192.168.12.2.

<Sysname> system-view

[Sysname] ovsdb server tcp ip 192.168.12.2 port 6632

Related commands

ovsdb server enable

ovsdb server ptcp

vtep access port

Use vtep access port to specify a site-facing interface as a VTEP access port.

Use undo vtep access port to restore the default.

Syntax

vtep access port

undo vtep access port

Default

An interface is not a VTEP access port.

Views

Layer 2 aggregate interface view

Layer 2 Ethernet interface view

Layer 3 interface view

Predefined user roles

network-admin

context-admin

Usage guidelines

For controllers to manage a site-facing interface, you must specify the interface as a VTEP access port.

Examples

# Specify GigabitEthernet 1/0/1 as a VTEP access port.

<Sysname> system-view

[Sysname] interface gigabitethernet 1/0/1

[Sysname-GigabitEthernet1/0/1] vtep access port

vtep enable

Use vtep enable to enable the OVSDB VTEP service.

Use undo vtep enable to disable the OVSDB VTEP service.

Syntax

vtep enable

undo vtep enable

Default

The OVSDB VTEP service is disabled.

Views

System view

Predefined user roles

network-admin

context-admin

Examples

# Enable the OVSDB VTEP service.

<Sysname> system-view

[Sysname] vtep enable

vxlan tunnel flooding-proxy

Use vxlan tunnel flooding-proxy to enable flood proxy on multicast VXLAN tunnels.

Use undo vxlan tunnel flooding-proxy to disable flood proxy on multicast VXLAN tunnels.

Syntax

vxlan tunnel flooding-proxy

undo vxlan tunnel flooding-proxy

Default

Flood proxy is disabled on multicast VXLAN tunnels.

Views

System view

Predefined user roles

network-admin

context-admin

Usage guidelines

If you use a flood proxy server, you must enable flood proxy globally on multicast tunnels. Then the multicast tunnels are converted into flood proxy tunnels. The VTEP sends broadcast, multicast, and unknown unicast traffic for a VXLAN to the flood proxy server through the tunnels. The flood proxy server then replicates and forwards flood traffic to remote VTEPs.

The vxlan tunnel flooding-proxy command and its undo form affect only VXLAN tunnels that are issued after the vxlan tunnel flooding-proxy command.

Examples

# Enable flood proxy on all multicast VXLAN tunnels.

<Sysname> system

[Sysname] vxlan tunnel flooding-proxy

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网