1 About the DD-2162-3L5 power supply

IMPORTANT

IMPORTANT:

·     The information in this document might differ from your product if it contains custom configuration options or features.

·     The figures in this document are for illustration only.

·     The model name of a hardware option in this document might differ slightly from its model name label. A model name label might add a prefix or suffix to the hardware-coded model name. For example, the DD-2162-3L5 power supply model represents power supply labels including UN-DD-2162-3L5, which has a different prefix.

 

Table1-1 DD-2162-3L5 power supply description

Item

Description

Product code

DD-2162-3L5

Detailed description

1600W 48V DC Power Supply (LT-R1-Platinum)(CTO&BTO)

Sales code

0231AHRV

Lowest-level code

0227A01S

 

Figure1-1 DD-2162-3L5 power supply

 

Figure1-2 Front panel

(1) Handle

(2) Power receptacle

(3) Latch

(4) Power supply LED

 

2 Key features

Protection

The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output limit, output short circuit, and overtemperature conditions.

Redundancy

Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing.

Hot swapping

You can install or remove a power supply when the device is operating.

Tool-free replacement

You can replace a power supply without using tools.

3 Technical specifications

Table3-1 Technical specifications

Item

Specifications

Rated input voltage range

–48 VDC to –60 VDC @ 1600 W

Rated input current

40 A Max @ –48 VDC to –60 VDC

Maximum rated heat output

6073 BTU/hr @ –48 VDC

Maximum rated output power

1600 W

Frequency

N/A

Efficiency at 50% load

80 Plus Platinum

Temperature

·     Operating: 0°C to 55°C (32°F to 131°F)

·     Storage: –40°C to +85°C (–40°F to +185°F)

Operating humidity

5% to 90%

Maximum altitude

5000 m (16404.20 ft)

Redundancy

Yes

Cold backup

Yes

 

4 LEDs

Table4-1 Power supply LED description

LED status

Description

Steady green

The power supply is operating correctly.

Flashing green (1 Hz)

Power is being input correctly but the system is not powered on.

Flashing green (0.33 Hz)

The power supply is in standby state and does not output power.

Flashing green (2 Hz)

The power supply is updating its firmware.

Steady amber

·     The power supply is faulty.

·     The power supply does not have power input, but the other power supply has correct power input.

Flashing amber (1 Hz)

An alarm has occurred on the power supply.

Off

No power supplies have power input, which can be caused by an incorrect power cord connection or power source shutdown.

 

5 Installing and removing the power supply

For information about installing and removing the power supply, see the user guide for the device.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网