Contents

Configuring IP forwarding basic settings························································ 1

About FIB table······························································································································· 1

Saving the IP forwarding entries to a file··························································································· 2

Keeping the TTL or hop limit unchanged in packets passing through tunnel interfaces and VSI interfaces       2

Forwarding ARP packets to a remote device through a VXLAN tunnel················································ 2

Forwarding ND packets to a remote device through a VXLAN tunnel·················································· 3

Forwarding IP packets with TTL 1 and specific destination IP address················································ 3

Forwarding IPv6 packets with HopLimit 1 and specific destination IP address···································· 4

Enabling IPv4 FIB entry consistency check······················································································· 4

Display and maintenance commands for FIB table············································································ 4

Configuring load sharing··················································································· 6

About load sharing·························································································································· 6

Configuring load sharing mode········································································································ 6

Specifying the hash calculation mode for received packet fragments················································· 7

Enabling IPv4 bandwidth-based load sharing···················································································· 7

Enabling local-first load sharing······································································································· 8

Enabling symmetric load sharing······································································································ 8

Display and maintenance commands for load sharing······································································· 8

Loading sharing configuration examples··························································································· 9

Example: Configuring load sharing based on source and destination addresses·························· 9

 


Configuring IP forwarding basic settings

About FIB table

A device uses the FIB table to make packet forwarding decisions.

A device selects optimal routes from the routing table, and puts them into the FIB table. Each FIB entry specifies the next hop IP address and output interface for packets destined for a specific subnet or host.

For more information about the routing table, see Layer 3—IP Routing Configuration Guide.

Use the display fib command to display the FIB table. The following example displays the entire FIB table.

<Sysname> display fib

 

Destination count: 8 FIB entry count: 8

 

Flag:

  U:Usable   G:Gateway   H:Host   B:Blackhole   D:Dynamic   S:Static

  R:Relay     F:FRR

 

Destination/Mask   Nexthop         Flag     OutInterface/Token       Label

0.0.0.0/32         127.0.0.1       UH       InLoop0                  Null

127.0.0.0/8        127.0.0.1       U        InLoop0                  Null

127.0.0.0/32       127.0.0.1       UH       InLoop0                  Null

127.0.0.1/32       127.0.0.1       UH       InLoop0                  Null

127.255.255.255/32 127.0.0.1       UH       InLoop0                  Null

224.0.0.0/4        0.0.0.0         UB       NULL0                    Null

224.0.0.0/24       0.0.0.0         UB       NULL0                    Null

255.255.255.255/32 127.0.0.1       UH       InLoop0                  Null

A FIB entry includes the following items:

·     Destination—Destination IP address.

·     Mask—Network mask. The mask and the destination address identify the destination network. A logical AND operation between the destination address and the network mask yields the address of the destination network. For example, if the destination address is 192.168.1.40 and the mask 255.255.255.0, the address of the destination network is 192.168.1.0. A network mask includes a certain number of consecutive 1s. It can be expressed in dotted decimal format or by the number of the 1s.

·     Nexthop—IP address of the next hop.

·     Flag—Route flag.

·     OutInterface—Output interface.

·     Token—MPLS Label Switched Path index number.

·     Label—Inner label.

Saving the IP forwarding entries to a file

Restrictions and guidelines

The feature automatically creates the file if you specify a nonexistent file. If the file already exists, this feature overwrites the file content.

This feature triggers one-time saving of the IP forwarding entries.

To automatically save the IP forwarding entries periodically, configure a schedule for the device to automatically run the ip forwarding-table save command. For information about scheduling a task, see Fundamentals Configuration Guide.

Procedure

To save the IP forwarding entries to a file, execute the following command in any view:

ip forwarding-table save filename filename

Keeping the TTL or hop limit unchanged in packets passing through tunnel interfaces and VSI interfaces

About this task

On a private network using VXLANs or tunnels, the gateway decrements the value in the TTL or Hop Limit field by one in packets passing through VSI interfaces or tunnel interfaces by default. If you do not want the gateway to change the TTL or hop limit in these packets, configure this feature on the gateway.

Procedure

1.     Enter system view.

system-view

2.     Configure the device not to change the TTL or hop limit in the packets passing through tunnel interfaces and VSI interfaces.

forwarding tunnel-ttl-unvaried

By default, the TTL or hop limit is decremented by one when a packet passes through a tunnel interface or VSI interface.

Forwarding ARP packets to a remote device through a VXLAN tunnel

About this task

In ARP flooding suppression, if a device receives an ARP packet that uses the device's MAC as the destination MAC but another device's IP as the destination IP, the device discards the packet. You can perform this task for the device to forward such packets to a specific VXLAN tunnel.

Make sure the specified tunnel interface is a manual created VXLAN over IPv4 tunnel.

Procedure

1.     Enter system view.

system-view

2.     Enable forwarding ARP packets with a specific destination address to the specified VXLAN tunnel.

forwarding arp-packet destination [ vpn-instance vpn-instance-name ] ip-address interface tunnel number

By default, the device delivers ARP packets to the CPU.

Forwarding ND packets to a remote device through a VXLAN tunnel

About this task

In ND flooding suppression, if a device receives an ND packet that uses the device's MAC as the destination MAC but another device's IP as the destination IP, the device discards the packet. You can perform this task for the device to forward such packets to a specific VXLAN tunnel.

Make sure the specified tunnel interface is a manual created VXLAN over IPv4 tunnel.

Procedure

1.     Enter system view.

system-view

2.     Enable forwarding ND packets with a specific destination address to the specified VXLAN tunnel.

forwarding nd-packet destination [ vpn-instance vpn-instance-name ] ipv6-address interface tunnel number

By default, the device delivers ND packets to the CPU.

Forwarding IP packets with TTL 1 and specific destination IP address

About this task

This feature is typically configured on a device that acts as the gateway in the following scenario:

·     The device directly connects to an internal server.

·     The internal devices wish to receive IP packets destined to a specific IP address, but they do not care about the TTL value in the packets.

Upon receiving an IP packet destined to the specified destination IP address, the device forwards the packet with TTL of 1 instead of sending it to the CPU.

Procedure

1.     Enter system view.

system-view

2.     Enable forwarding IP packet with TTL of 1 if the packets are destined to the specified IP address.

forwarding ttl-exceeded-packet destination [ vpn-instance vpn-instance-name ] ip-address

By default, the device delivers IP packets to the CPU.

Forwarding IPv6 packets with HopLimit 1 and specific destination IP address

About this task

This feature is typically configured on a device that acts as the gateway in the following scenario:

·     The device directly connects to an internal server.

·     The internal devices wish to receive IPv6 packets destined to a specific IPv6 address, but they do not care about the HopLimit value in the packets.

Upon receiving an IPv6 packet destined to the specified destination IPv6 address, the device forwards the packet with HopLimit of 1 instead of sending it to the CPU.

Procedure

1.     Enter system view.

system-view

2.     Enable forwarding IPv6 packet with HopLimit of 1 if the packets are destined to the specified IP address.

forwarding hop-limit-exceeded destination [ vpn-instance vpn-instance-name ] ipv6-address

By default, the device delivers IPv6 packets to the CPU.

Enabling IPv4 FIB entry consistency check

About this task

Packet drops or incorrect forwarding might occur when the IPv4 FIB entries in hardware are inconsitent with FIB entries configured in software. To prevent these issues, enable IPv4 FIB entry consistency check.

This feature compares all IPv4 FIB entries in software with the IPv4 FIB entries in hardware regularly. If the device detects an inconsistency, the device performs the following tasks:

·     Generates a log.

·     Updates the IPv4 FIB entry in hardware with the IPv4 FIB entry in software.

Procedure

1.     Enter system view.

system-view

2.     Enable IPv4 FIB entry consistency check.

fib consistency-check enable

By default, IPv4 FIB entry consistency check is disabled.

Display and maintenance commands for FIB table

Execute display commands in any view.

 

Task

Command

Display FIB entries.

display fib [ vpn-instance vpn-instance-name ]  [ ip-address [ mask | mask-length ] ]

 


Configuring load sharing

About load sharing

If a routing protocol finds multiple equal-cost best routes to the same destination, the device forwards packets over the equal-cost routes to implement load sharing.

Configuring load sharing mode

About this task

In the per-flow load sharing mode, the device forwards flows over equal-cost routes. Packets of one flow travel along the same routes. You can configure the device to identify a flow based on the following criteria: source IP address, destination IP address, source port number, destination port number, IP protocol number, and ingress port.

In a complex network, when the traffic is not laod balanced proportionally, you can use the algorithm keyword to specify an algorithm to improve the sharing.

Restrictions and guidelines

If you use the ip load-sharing mode and link-aggregation global load-sharing mode commands multiple times, the most recent configuration takes effect. To ensure correct packet forwarding, make sure you configure the same load-sharing mode in the ip load-sharing mode and link-aggregation global load-sharing mode commands.

Procedure

1.     Enter system view.

system-view

2.     Configure load sharing.

In standalone mode:

ip load-sharing mode { per-flow [ algorithm algorithm-number  | [ dest-ip | dest-port | ingress-port | ip-pro | src-ip | src-port ] * | tunnel { all | inner | outer } ] | per-packet } { global | slot slot-number }

In IRF mode:

ip load-sharing mode { per-flow [ algorithm algorithm-number | [ dest-ip | dest-port | ingress-port | ip-pro | src-ip | src-port ] * | tunnel { all | inner | outer } ] | per-packet } { chassis chassis-number slot slot-number | global }

By default, the device performs per-flow load sharing based on the following criteria: source IP address, destination IP address, source port number, destination port number, IP protocol number, and ingress port.

3.     Display the load sharing path selected for a flow.

display ip load-sharing path ingress-port interface-type interface-number packet-format { ipv4oe dest-ip ip-address [ src-ip ip-address ] | ipv6oe dest-ipv6 ipv6-address [ src-ipv6 ipv6-address ] } [ dest-port port-id | ip-pro protocol-id | src-port port-id | vpn-instance vpn-instance-name ] *

The option settings in this command must match both the options displayed in the display ip load-sharing mode command and the field values in load shared packets. If the option settings do not meet the requirement, the path displayed by this command might be different from the real path for load sharing.

Specifying the hash calculation mode for received packet fragments

About this task

After receiving the first fragment and other fragments of a packet, the device uses the hash algorithm to calculate the forwarding paths for these fragments. By default, the calculated forwarding paths might be different, causing abnormal fragment reassembly.

To resolve this issue, perform this task to make sure that the device forwards the first fragment and other fragments of a packet along the same path.

Restrictions and guidelines

This command is mutually exclusive with the ip load-sharing mode or link-aggregation global load-sharing mode command.

Before using this command, make sure you have understood the potential impact:

·     TCP attack resistance will not take effect.

·     The number of applications supported by ACL will reduce.

·     All packet fragments can match ACL 3000.

Procedure

1.     Enter system view.

system-view

2.     Specify the hash calculation mode for packet fragments received on the device.

hardware-resource hash { normal | frag-enhance}

By default, the device might forward the first fragment and other fragments of a packet along different paths after hash calculation.

Enabling IPv4 bandwidth-based load sharing

About this task

This feature load shares flow traffic among multiple output interfaces based on their load percentages. The device calculates the load percentage for each output interface in terms of the interface expected bandwidth.

Devices that run load sharing protocols, such as Locator/ID Separation Protocol (LISP), implement load sharing based on the ratios defined by these protocols.

Restrictions and guidelines

This feature is mutually exclusive with enhanced ECMP mode, which is configured by using the ecmp mode enhanced command.

After you configure this feature, make sure the expected bandwidth of the interface does not  exceed the physical bandwidth of the interface.

Procedure

1.     Enter system view.

system-view

2.     Enable IPv4 bandwidth-based load sharing.

bandwidth-based-sharing

By default, the IPv4 bandwidth-based load sharing is disabled.

3.     (Optional.) Configure the expected bandwidth of the interface.

a.     Enter interface view.

interface interface-type interface-number

b.     Configure the expected bandwidth of the interface.

bandwidth bandwidth

By default, the expected bandwidth is the physical bandwidth of the interface.

Enabling local-first load sharing

About this task

Local-first load sharing distributes traffic preferentially across the output interfaces on the receiving IRF member device if output interfaces for multiple equal-cost routes are on different members. This feature enhances packets forwarding efficiency.

Procedure

1.     Enter system view.

system-view

2.     Enable local-first load sharing.

ip load-sharing local-first enable

By default, local-first load sharing is enabled.

Enabling symmetric load sharing

About this task

Symmetric load sharing ensures that bidirectional traffic specific to a source and destination address pair flow along the same path.

Procedure

1.     Enter system view.

system-view

2.     Enable symmetric load sharing.

ip load-sharing symmetric enable

By default, symmetric load sharing is disabled.

Display and maintenance commands for load sharing

Execute display commands in any view.

 

Task

Command

Display the load sharing mode in use.

In standalone mode:

display ip load-sharing mode slot slot-number

In IRF mode:

display ip load-sharing mode chassis chassis-number slot slot-number

Display the load sharing path selected for a flow.

display ip load-sharing path ingress-port interface-type interface-number packet-format { ipv4oe dest-ip ip-address [ src-ip ip-address ] | ipv6oe dest-ipv6 ipv6-address [ src-ipv6 ipv6-address ] } [ dest-port port-id | ip-pro protocol-id | src-port port-id | vpn-instance vpn-instance-name ] *

Loading sharing configuration examples

Example: Configuring load sharing based on source and destination addresses

Network configuration

As shown in Figure 1, Switch A has two equal-cost routes to Switch B. Configure load sharing on Switch A to forward packets through Switch B to the destination IP address 1.2.3.4/24.

Figure 1 Network diagram

Procedure

 

IMPORTANT

IMPORTANT:

By default, interfaces on the device are disabled (in ADM or Administratively Down state). To have an interface operate, you must use the undo shutdown command to enable that interface.

 

 

# On Switch A, assign FortyGigE 1/0/1 to VLAN 10, and FortyGigE 1/0/2 to VLAN 20.

<SwitchA> system-view

[SwitchA] vlan 10

[SwitchA-vlan10] port fortygige 1/0/1

[SwitchA-vlan10] quit

[SwitchA] vlan 20

[SwitchA-vlan20] port fortygige 1/0/2

[SwitchA-vlan20] quit

# On Switch A, configure IP addresses for VLAN-interface 10 and VLAN-interface 20.

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] ip address 10.1.1.1 24

[SwitchA-Vlan-interface10] quit

[SwitchA] interface vlan-interface 20

[SwitchA-Vlan-interface20] ip address 20.1.1.1 24

[SwitchA-Vlan-interface20] quit

# On Switch B, assign FortyGigE 1/0/1 to VLAN 10, and FortyGigE 1/0/2 to VLAN 20.

<SwitchB> system-view

[SwitchB] vlan 10

[SwitchB-vlan10] port fortygige 1/0/1

[SwitchB-vlan10] quit

[SwitchB] vlan 20

[SwitchB-vlan20] port fortygige 1/0/2

[SwitchB-vlan20] quit

# On Switch B, configure IP addresses for VLAN-interface 10 and VLAN-interface 20.

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] ip address 10.1.1.2 24

[SwitchB-Vlan-interface10] quit

[SwitchB] interface vlan-interface 20

[SwitchB-Vlan-interface20] ip address 20.1.1.2 24

[SwitchB-Vlan-interface20] quit

# On Switch A, configure two static routes to the destination IP address.

<SwitchA> system-view

[SwitchA] ip route-static 1.2.3.4 24 10.1.1.2

[SwitchA] ip route-static 1.2.3.4 24 20.1.1.2

[SwitchA] quit

# On Switch A, display FIB entries matching the destination IP address 1.2.3.4.

<SwitchA> display fib 1.2.3.4

Destination count: 1 FIB entry count: 2

Flag:

  U:Usable   G:Gateway   H:Host   B:Blackhole   D:Dynamic   S:Static

  R:Relay     F:FRR

Destination/Mask   Nexthop         Flag     OutInterface/Token       Label

1.2.3.0/24         10.1.1.2        USGR     Vlan10                   Null

1.2.3.0/24         20.1.1.2        USGR     Vlan20                   Null

# On Switch A, configure per-flow load sharing based on the source IP address and destination IP address.

<SwitchA> system-view

[SwitchA] ip load-sharing mode per-flow dest-ip src-ip global

Verifying the configuration

# Verify that Switch A implements load sharing.

<SwitchA> display counters outbound interface FortyGigE

Interface         Total (pkts)   Broadcast (pkts)   Multicast (pkts)  Err (pkts)

FGE1/0/1                 1045                  0                  0           0

FGE1/0/2                 1044                  0                  0           0

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网