- Table of Contents
- Related Documents
-
Title | Size | Download |
---|---|---|
01-Text | 2.80 MB |
1 Product models and technical specifications
2 FRUs and compatibility matrixes
1/10GBASE-T autosensing Ethernet port
1 Product models and technical specifications
Product models
H3C S6860 switch series includes the S6860-54HF, S6860-30HF, and S6860-54HT models.
Technical specifications
Table1-1 Technical specifications
Item |
S6860-54HF |
S6860-30HF |
S6860-54HT |
||
Product code |
LS-6860-54HF |
LS-6860-30HF |
LS-6860-54HT |
||
Dimensions (H × W × D) |
44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
44 × 440 × 460 mm (1.73 × 17.32 × 18.11 in) |
||
Weight |
≤ 10 kg (22.05 lb) |
≤ 10 kg (22.05 lb) |
≤ 10 kg (22.05 lb) |
||
Console ports |
· 1 × mini USB console port · 1 × serial console port |
· 1 × mini USB console port · 1 × serial console port |
· 1 × mini USB console port · 1 × serial console port |
||
Management Ethernet ports |
· 1 × 10M/100M/1000MBASE-T copper port · 1 × SFP port |
· 1 × 10M/100M/1000MBASE-T copper port · 1 × SFP port |
· 1 × 10M/100M/1000MBASE-T copper port · 1 × SFP port |
||
USB ports |
1 |
1 |
1 |
||
10GBASE-T Ethernet ports |
N/A |
N/A |
48 NOTE: Ports 29 to 36 can only operate at 10 Gbps. Ports 1 to 28 and ports 37 to 48 can operate at 10 Gbps or 1 Gbps. |
||
SFP+ ports |
48 NOTE: Ports 29 to 36 can only operate at 10 Gbps. Ports 1 to 28 and ports 37 to 48 can operate at 10 Gbps or 1 Gbps. |
24 |
N/A |
||
QSFP+ ports |
Up to 6 |
Up to 6 |
Up to 6 |
||
QSFP28 ports |
Up to 2 |
Up to 2 |
Up to 2 |
||
Fan tray slots |
4 |
4 |
5 |
||
Power supply slots |
2 |
2 |
2 |
||
Input voltage |
PSR250-12A/PSR250-12A1: · AC input ¡ Rated voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage: 90 to 290 VAC @ 47 to 63 Hz · High-voltage DC input ¡ Rated voltage: 240 VDC ¡ Max voltage: 180 to 320 VDC PSR450-12A/PSR450-12A1: · AC input ¡ Rated voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage: 90 to 290 VAC @ 47 to 63 Hz · High-voltage DC input ¡ Rated voltage: 240 VDC ¡ Max voltage: 180 to 320 VDC PSR450-12AHD: · AC input ¡ Rated voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage: 90 to 290 VAC @ 47 to 63 Hz · High-voltage DC input ¡ Rated voltage: 240 to 380 VDC ¡ Max voltage: 180 to 400 VDC PSR450-12D: · Rated voltage: –48 to –60 VDC · Max voltage: –36 to –72 VDC |
PSR450-12A/PSR450-12A1: · AC input ¡ Rated voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage: 90 to 290 VAC @ 47 to 63 Hz · High-voltage DC input ¡ Rated voltage: 240 VDC ¡ Max voltage: 180 to 320 VDC PSR450-12AHD: · AC input ¡ Rated voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage: 90 to 290 VAC @ 47 to 63 Hz · High-voltage DC input ¡ Rated voltage: 240 to 380 VDC ¡ Max voltage: 180 to 400 VDC PSR450-12D: · Rated voltage: –48 to –60 VDC · Max voltage: –36 to –72 VDC |
|||
Minimum power consumption (For the power consumption data collection standard, see Table1-2.) |
PSR250-12A/PSR250-12A1: · Single AC input: 66 W · Dual AC inputs: 74 W PSR450-12A/PSR450-12A1: · Single AC input: 68 W · Dual AC inputs: 76 W PSR450-12AHD: · Single DC input: 65 W · Dual DC inputs: 73 W PSR450-12D: · Single DC input: 68 W · Dual DC inputs: 73 W |
PSR250-12A/PSR250-12A1: · Single AC input: 66 W · Dual AC inputs: 74 W PSR450-12A/PSR450-12A1: · Single AC input: 67 W · Dual AC inputs: 76 W PSR450-12AHD: · Single DC input: 65 W · Dual DC inputs: 73 W PSR450-12D: · Single DC input: 68 W · Dual DC inputs: 74 W |
PSR450-12A/PSR450-12A1 · Single AC input: 101 W · Dual AC inputs: 108 W PSR450-12AHD: · Single DC input: 95 W · Dual DC inputs: 105 W PSR450-12D: · Single DC input: 97 W · Dual DC inputs: 104 W |
||
Typical power consumption (For the power consumption data collection standard, see Table1-2.) |
PSR250-12A/PSR250-12A1: · Single AC input: 99 W · Dual AC inputs: 96 W PSR450-12A/PSR450-12A1: · Single AC input: 90 W · Dual AC inputs: 99 W |
PSR250-12A/PSR250-12A1: · Single AC input: 87 W · Dual AC inputs: 86 W PSR450-12A/PSR450-12A1: · Single AC input: 78 W · Dual AC inputs: 77 W |
PSR450-12A/PSR450-12A1 · Single AC input: 206 W · Dual AC inputs: 212 W PSR450-12D: · Single DC input: 205 W · Dual DC inputs: 211 W |
||
Maximum power consumption (For the power consumption data collection standard, see Table1-2.) |
PSR250-12A/PSR250-12A1: · Single AC input: 171 W · Dual AC inputs: 178 W PSR450-12A/PSR450-12A1: · Single AC input: 169 W · Dual AC inputs: 178 W PSR450-12AHD: · Single DC input: 166 W · Dual DC inputs: 173 W PSR450-12D: · Single DC input: 169 W · Dual DC inputs: 176 W |
PSR250-12A/PSR250-12A1: · Single AC input: 130 W · Dual AC inputs: 134 W PSR450-12A/PSR450-12A1: · Single AC input: 130 W · Dual AC inputs: 138 W PSR450-12AHD: · Single DC input: 131 W · Dual DC inputs: 139 W PSR450-12D: · Single DC input: 133 W · Dual DC inputs: 140 W |
PSR450-12A/PSR450-12A1: · Single AC input: 255 W · Dual AC inputs: 258 W PSR450-12AHD: · Single DC input: 254 W · Dual DC inputs: 261 W PSR450-12D: · Single DC input: 259 W · Dual DC inputs: 264 W |
||
Chassis leakage current compliance |
UL60950-1/EN60950-1/IEC60950-1/GB4943 |
||||
Melting current of power supply fuse |
PSR250-12A/PSR250-12A1: 6.3 A @ 250 VAC PSR450-12A/PSR450-12A1: 10 A @ 250 VAC PSR450-12D: 20 A @ 125 V PSR450-12AHD: 10 A @ 420 V |
PSR450-12A/PSR450-12A1: 10 A @ 250 VAC PSR450-12D: 20 A @ 125 V PSR450-12AHD: 10 A @ 420 V |
|||
Sound pressure level at 27°C (80.6°F) |
52.5 dB(A) |
52.7 dB(A) |
52.4 dB(A) |
||
Operating temperature |
0°C to 45°C (32°F to 113°F) |
||||
Operating humidity |
10% RH to 90% RH, noncondensing |
||||
Fire resistance compliance |
UL60950-1/EN60950-1/IEC60950-1/GB4943 |
||||
Table1-2 Power consumption data collection standard
Item |
Static power consumption |
Typical power consumption |
Maximum power consumption |
Configuration |
· Two power supplies · No transceiver modules/cables installed in ports |
· Two power supplies · Fully configured with copper cables |
· Two power supplies · Fully configured with transceiver modules |
Load |
N/A |
50% load |
100% load |
Chassis views
S6860-54HF
Figure1-1 Front panel
(1) SFP+ port LED |
(2) SFP+ port |
(3) QSFP+ port LED |
(4) QSFP28 port LED |
(5) QSFP28 port |
(6) QSFP+ port |
(1) System status LED (SYS) |
(2) LINK/ACT LED for the copper management Ethernet port |
(3) LINK/ACT LED for the fiber management Ethernet port |
(4) Fan tray 1 |
(5) Fan tray 2 |
(6) Fan tray 3 |
(7) Fan tray 4 |
(8) Power supply 1 |
(9) Power supply 2 |
(10) Fiber management Ethernet port |
(11) Copper management Ethernet port |
(12) Console port |
(13) Mini USB console port |
(14) USB port |
An S6860-54HF switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. In Figure1-2, two PSR250-12A power supplies are installed in the power supply slots.
An S6860-54HF switch comes with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure1-2, four LSPM1FANSA fan trays are installed in the fan tray slots.
(1) Primary grounding point |
(2) Auxiliary grounding point |
S6860-54HT
Figure1-4 Front panel
(1) 1/10GBASE-T autosensing Ethernet port |
(2) 1/10GBASE-T autosensing Ethernet port LED |
(3) QSFP+ port |
(4) QSFP28 port |
(5) QSFP28 port LED |
(6) QSFP+ port LED |
(1) Fiber management Ethernet port |
(2) Copper management Ethernet port |
(3) Console port |
(4) Mini USB console port |
(5) Fan tray 1 |
(6) Fan tray 2 |
(7) Fan tray 3 |
(8) Fan tray 4 |
(9) Fan tray 5 |
(10) Power supply 1 |
(11) Power supply 2 |
(12) USB port |
(13) System status LED (SYS) |
(14) LINK/ACT LED for the copper management Ethernet port |
(15) LINK/ACT LED for the fiber management Ethernet port |
An S6860-54HT switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. In Figure1-5, two PSR450-12A1 power supplies are installed in the power supply slots.
An S6860-54HT switch comes with the five fan tray slots empty. You must install five fan trays of the same model for the switch. In Figure1-5, five LSPM1FANSB fan trays are installed in the fan tray slots.
Figure1-6 Left side panel
(1) Primary grounding point |
(2) Auxiliary grounding point |
S6860-30HF
Figure1-7 Front panel
(1) SFP+ port LED |
(2) SFP+ port |
(3) QSFP+ port LED |
(4) QSFP28 port LED |
(5) QSFP28 port |
(6) QSFP+ port |
Figure1-8 Rear panel
(1) System status LED (SYS) |
(2) LINK/ACT LED for the copper management Ethernet port |
(3) LINK/ACT LED for the fiber management Ethernet port |
(4) Fan tray 1 |
(5) Fan tray 2 |
(6) Fan tray 3 |
(7) Fan tray 4 |
(8) Power supply 1 |
(9) Power supply 2 |
(10) Fiber management Ethernet port |
(11) Copper management Ethernet port |
(12) Console port |
(13) Mini USB console port |
(14) USB port |
An S6860-30HF switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. In Figure1-2, two PSR250-12A power supplies are installed in the power supply slots.
An S6860-30HF switch comes with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure1-2, four LSPM1FANSA fan trays are installed in the fan tray slots.
Figure1-9 Left side panel
(1) Primary grounding point |
(2) Auxiliary grounding point |
2 FRUs and compatibility matrixes
CAUTION: · Select fan trays and power supplies with airflow directions that meet the ventilation requirements at the installation site. As a best practice, make sure the power supplies and fan trays have the same airflow direction. · Do not install fan trays of different models on the same switch. · Do not install power supplies of different models on the same switch. |
Table2-1 Compatibility matrix between the FRUs and S6860 switches
FRUs |
Part No. in BOM |
S6860-54HF |
S6860-30HF |
S6860-54HT |
Power supplies |
||||
PSR250-12A |
0231A6M0 |
Yes |
Yes |
No |
PSR250-12A1 |
0231A8FP |
Yes |
Yes |
No |
PSR450-12A |
0231A6N9 |
Yes |
Yes |
Yes |
PSR450-12A1 |
0231A6NC |
Yes |
Yes |
Yes |
PSR450-12AHD |
0231A6NA |
Yes |
Yes |
Yes |
PSR450-12D |
0231A6NB |
Yes |
Yes |
Yes |
Fan trays |
|
|||
LSPM1FANSA |
0231A2VT |
Yes |
Yes |
Yes |
LSPM1FANSB |
0231A2VU |
Yes |
Yes |
Yes |
Power supplies
CAUTION: When the switch has power supplies in redundancy, you can replace a power supply without powering off the switch. Make sure the power supply to be replaced is powered off before you replace it. |
IMPORTANT: As a best practice, use power supplies of the same model in 1+1 redundancy for power supply. |
Table2-2 Power supply specifications
Power supply |
Specifications |
Remarks |
PSR250-12A (air intake on power supply panel) PSR250-12A1 (air exhaust on power supply panel) |
· AC input: ¡ Rated input voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max input voltage: 90 to 290 VAC @ 47 to 63 Hz ¡ Max output power: 250 W · DC input: ¡ Rated input voltage: 240 VDC ¡ Max input voltage: 180 to 320 VDC ¡ Max output power: 250 W |
For more information about the power supplies, see H3C PSR250-12A & PSR250-12A1 Power Modules User Manual. |
PSR450-12A (air intake on power supply panel) PSR450-12A1 (air exhaust on power supply panel) |
· AC input: ¡ Rated input voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max input voltage: 90 to 290 VAC @ 47 to 63 Hz ¡ Max output power: 450 W · DC input: ¡ Rated input voltage: 240 VDC ¡ Max input voltage: 180 to 320 VDC ¡ Max output power: 450 W |
For more information about the power supplies, see H3C PSR450 Power Module Series User Manual. |
PSR450-12AHD (air exhaust on power supply panel) |
· AC input ¡ Rated voltage: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage: 90 to 290 VAC @ 47 to 63 Hz ¡ Max output power: 450 W · High-voltage DC input ¡ Rated voltage: 240 to 380 VDC ¡ Max voltage: 180 to 400 VDC ¡ Max output power: 450 W |
|
PSR450-12D (air exhaust on power supply panel) |
· Rated input voltage: –48 to –60 VDC · Max input voltage: –36 to –72 VDC · Max output power: 450 W |
Fan trays
Table2-3 Fan tray specifications
Item |
Specifications |
LSPM1FANSA |
|
Fans |
One 40 × 40 × 28 mm (1.57 × 1.57 × 1.10 in) fan |
Fan speed |
20000 R.P.M |
Max airflow |
20 CFM (0.57 m3/min) |
Airflow direction |
Air intake on fan tray panel |
Input voltage |
12 V |
Maximum power consumption |
9.8 W |
Documentation reference |
H3C LSPM1FANSA & LSPM1FANSB Fan Trays User Guide |
LSPM1FANSB |
|
Fans |
One 40 × 40 × 28 mm (1.57 × 1.57 × 1.10 in) fan |
Fan speed |
20000 R.P.M |
Max airflow |
20 CFM (0.57 m3/min) |
Airflow direction |
Air exhaust on fan tray panel |
Input voltage |
12 V |
Maximum power consumption |
9.8 W |
Documentation reference |
H3C LSPM1FANSA & LSPM1FANSB Fan Trays User Guide |
3 Ports and LEDs
Ports
Console port
The switch has two console ports: serial console port and Mini USB console port.
Table3-1 Console port specifications
Item |
Console port |
Mini USB console port |
Connector type |
RJ-45 |
USB mini-Type B |
Compliant standard |
EIA/TIA-232 |
USB 2.0 |
Transmission baud rate |
9600 bps (default) to 115200 bps |
|
Services |
· Provides connection to an ASCII terminal. · Provides connection to the serial port of a local or remote (through a pair of modems) PC running terminal emulation program. |
· Provides connection to an ASCII terminal. · Provides connection to the USB port of a local PC running terminal emulation program. |
Management Ethernet port
The switch provides a copper and a fiber management Ethernet port.
You can connect this port to a PC or management station for loading and debugging software or remote management.
Table3-2 Copper management Ethernet port specifications
Item |
Specification |
Connector type |
RJ-45 |
Connector quantity |
1 |
Port transmission rate |
10/100/1000 Mbps, half/full duplex |
Transmission medium and max transmission distance |
100 m (328.08 ft) over category-5 twisted pair cable |
Functions and services |
Switch software and Boot ROM upgrade, network management |
Table3-3 Fiber management Ethernet port specifications
Item |
Specification |
Connector type |
LC |
Connector quantity |
1 |
Port transmission rate |
100/1000 Mbps, full duplex |
Transmission medium and max transmission distance |
|
Functions and services |
Software upgrade and network management |
Table3-4 FE SFP transceiver modules
FE SFP transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Max transmission distance |
SFP-FE-SX-MM1310-A |
1310 |
LC |
Multi-mode, 50/125 |
2 km (1.24 miles) |
Multi-mode, 62.5/125 |
||||
SFP-FE-LX-SM1310-A |
1310 |
LC |
Single-mode, 9/125 |
15 km (9.32 miles) |
SFP-FE-LH40-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
40 km (24.86 miles) |
USB port
The switch has one OHC-compliant USB2.0 port that can upload and download data at a rate up to 480 Mbps. You can use this USB port to access the file system on the Flash of the switch, for example, to upload or download application and configuration files.
|
NOTE: USB devices from different manufacturers vary in compatibilities and drivers. H3C does not guarantee the correct operation of all USB devices on the switch. If a USB device fails to operate on the switch, replace it with one from another manufacturer. |
SFP+ port
The S6860-54HF and S6860-30HF switches provide SFP+ ports. The SFP+ ports support Gigabit SFP transceiver modules described in Table3-5, 10-Gigabit SFP+ transceiver modules described in Table3-6, SFP+ copper cables described in Table3-7, and SFP+ fiber cables described in Table3-8.
Ports 29 to 36 on the front panel of the S6860-54HF switch do not support Gigabit SFP copper transceiver modules or Gigabit SFP fiber transceiver modules.
Table3-5 Gigabit SFP transceiver modules available for the SFP+ ports
Gigabit SFP transceiver module |
Central wavelength (nm) |
Connector |
Cable/Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
Gigabit SFP copper transceiver module |
|||||
SFP-GE-T |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
SFP-GE-T-D |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
Gigabit SFP fiber transceiver module |
|||||
SFP-GE-SX-MM850-A SFP-GE-SX-MM850-D |
850 |
LC |
Multi-mode, 50/125 |
500 |
550 m (1804.46 ft) |
400 |
500 m (1640.42 ft) |
||||
Multi-mode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
160 |
200 m (656.17 ft) |
||||
SFP-GE-LX-SM1310-A |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
Multi-mode, 50/125 |
500 or 400 |
550 m (1804.46 ft) |
|||
Multi-mode, 62.5/125 |
500 |
550 m (1804.46 ft) |
|||
SFP-GE-LX-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310 SFP-GE-LH40-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 SFP-GE-LH80-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-GE-LH100-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
100 km (62.14 miles) |
IMPORTANT: · Installed with an SFP-GE-T or SFP-GE-T-D transceiver module, an SFP+ port can operate only at 1 Gbps. · If the switch connects to the peer device through an SFP-GE-T or SFP-GE-T-D transceiver module, packet loss occurs when the switch restarts, because the peer interface comes up before the local interface can come up, As a best practice, configure dynamic link aggregation to avoid such an issue if the switch is connected to the peer device through an aggregate link. |
Table3-6 10-Gigabit SFP+ transceiver modules available for the SFP+ ports
10-Gigabit SFP+ transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
SFP-XG-SX-MM850-A |
850 |
LC |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multi-mode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-LX-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1330-BIDI |
TX: 1330 RX: 1270 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1270-BIDI |
TX: 1270 RX: 1330 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
CAUTION: · Use BIDI transceiver modules in matched pair. For example, if one end uses an SFP-XG-LX-SM1270-BIDI transceiver module, the other end must use an SFP-XG-LX-SM1330-BIDI transceiver module. · The SFP-XG-LX-SM1270-BIDI and SFP-XG-LX-SM1330-BIDI transceiver modules are supported only in R2612P06 and later. |
Table3-7 SFP+ copper cables available for the SFP+ ports
SFP+ copper cable |
Max transmission distance |
LSWM1STK |
0.65 m (2.13 ft) |
LSWM2STK |
1.2 m (3.94 ft) |
LSWM3STK |
3 m (9.84 ft) |
LSTM1STK |
5 m (16.40 ft) |
Table3-8 SFP+ fiber cables available for the SFP+ ports
SFP+ fiber cable |
Max transmission distance |
Data rate |
SFP-XG-D-AOC-7M |
7 m (22.97 ft) |
10.31 Gbps |
SFP-XG-D-AOC-10M |
10 m (32.81 ft) |
|
SFP-XG-D-AOC-20M |
20 m (65.62 ft) |
Figure3-1 SFP+ copper cable
(1) Connector |
(2) Pull latch |
Figure3-2 SFP+ fiber cable
|
NOTE: · As a best practice, use H3C SFP transceiver modules, SFP+ transceiver modules, or SFP+ cables for the SFP+ ports on the switch. The H3C SFP transceiver modules, SFP+ transceiver modules, and SFP+ cables are subject to change over time. For the most up-to-date list of SFP transceiver modules, SFP+ transceiver modules, and SFP+ cables, contact H3C Support or marketing staff. · For more information about H3C SFP transceiver modules, SFP+ transceiver modules, and SFP+ cables, see H3C Transceiver Modules User Guide. |
QSFP+ port
The switch provides fixed QSFP+ ports. You can install QSFP+ transceiver modules in Table3-9, QSFP+ cables in Table3-10, and QSFP+ to SFP+ cables in Table3-11 in the QSFP+ ports as needed.
Table3-9 QSFP+ transceiver modules available for the QSFP+ ports
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
|
QSFP-40G-SR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-CSR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
4700 |
400 m (1312.33 ft) |
||||
QSFP-40G-BIDI-SR-MM850 |
850 |
LC |
Multi-mode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-BIDI-WDM850 |
Four lanes: · 850 · 880 · 910 · 940 |
LC |
Multi-mode, 50/125 |
2000 |
240 m (787.40 ft) |
4700 |
350 m (1148.29 ft) |
||||
QSFP-40G-LR4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-40G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-40G-LR4-PSM1310 |
1310 |
MPO |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
IMPORTANT: QSFP-40G-BIDI-WDM850 transceiver modules are supported only in R2612P06 and later. |
Table3-10 QSFP+ cables available for the QSFP+ ports
QSFP+ cable |
Max transmission distance |
LSWM1QSTK0 |
1 m (3.28 ft) |
LSWM1QSTK1 |
3 m (9.84 ft) |
LSWM1QSTK2 |
5 m (16.40 ft) |
Table3-11 QSFP+ to SFP+ cables available for the QSFP+ ports
QSFP+ to SFP+ cable |
Max transmission distance |
LSWM1QSTK3 |
1 m (3.28 ft) |
LSWM1QSTK4 |
3 m (9.84 ft) |
LSWM1QSTK5 |
5 m (16.40 ft) |
Table3-12 QSFP+ fiber cables available for the QSFP+ ports
QSFP+ fiber cable |
Max transmission distance |
Data rate |
QSFP-40G-D-AOC-3M |
3 m (9.84 ft) |
40 Gbps |
QSFP-40G-D-AOC-7M |
7 m (22.97 ft) |
|
QSFP-40G-D-AOC-10M |
10 m (32.81 ft) |
|
QSFP-40G-D-AOC-20M |
20 m (65.62 ft) |
Figure3-3 QSFP+ cable
(1) Connector |
(2) Pull latch |
Figure3-4 QSFP+ to SFP+ cable
(1) QSFP+ module |
(2) QSFP+ side pull latch |
(3) SFP+ side pull latch |
(4) SFP+ module |
Figure3-5 QSFP+ fiber cable
IMPORTANT: You can use a QSFP-40G-SR4-MM850 or QSFP-40G-CSR4-MM850 transceiver module to connect a QSFP+ port to four SFP+ ports. The QSFP+ transceiver module and SFP+ transceiver modules to be connected must be the same in specifications, including central wavelength and fiber type. |
|
NOTE: · As a best practice, use H3C QSFP+ transceiver modules, QSFP+ cables, or QSFP+ to 4 × SFP+ cables for the QSFP+ ports on the switch. The H3C QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to 4 × SFP+ cables available for the interface cards are subject to change over time. For the most recent list of QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to 4 × SFP+ cables available for the interface cards, contact H3C Support or marketing staff. · For more information about H3C QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to 4 × SFP+ cables, see H3C Transceiver Modules User Guide. |
QSFP28 port
The switch provides QSFP28 ports. The QSFP28 ports are 40GE ports by default. To change the ports to 100GE ports, execute the related command from the CLI. For more information, see Ethernet interface commands in H3C S6860 Switch Series Command References.
When a QSFP28 port operates as a 40GE port, the QSFP+ modules in Table3-9, QSFP+ cables in Table3-10, QSFP+ to SFP+ cables in Table3-11, and QSFP+ fiber cables in Table3-12 are available for the QSFP28 port.
A QSFP28 port does not support one-to-four splitting when it operates as a 100GE port. When a QSFP28 port operates as a 100GE port, the QSFP28 modules in Table3-13, QSFP28 copper cables in Table3-14, QSFP+ modules in Table3-9, QSFP+ cables in Table3-10, and QSFP+ fiber cables in Table3-12 are available for the QSFP28 port.
Table3-13 QSFP28 transceiver modules available for the QSFP28 ports
Model |
Central wavelength (nm) |
Connector |
Cable/Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
QSFP-100G-SR4-MM850 QSFP-100G-SR4-MM850-A |
850 |
MPO (PC polished, 12-fiber) |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
||||
QSFP-100G-eSR4-MM850 |
850 |
MPO (PC polished, 12-fiber) |
Multi-mode, 50/125 |
4700 |
300 m (984.25 ft) |
QSFP-100G-BIDI-MM850 (end of sale) |
Two lanes: · 855 · 908 |
LC |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
||||
QSFP-100G-PSM4-SM1310 |
1310 |
MPO (APC polished, 12-fiber) |
Single-mode, 9/125 |
N/A |
0.5 km (0.31 miles) |
QSFP-100G-LR4-WDM1300 QSFP-100G-LR4-WDM1300-A |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-100G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-100G-CWDM4-SM1300-A |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-100G-ER4L-WDM1300 |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
QSFP-100G-SWDM4-MM850 |
Four lanes: · 850 · 880 · 910 · 940 |
LC |
Multi-mode, 50/125 |
2000 |
75 m (246.06 ft) |
4700 |
100 m (328.08 ft) |
IMPORTANT: · QSFP-100G-SWDM4-MM850 transceiver modules are supported only in R2612P01 and later. · The QSFP-100G-BIDI-MM850 and QSFP-100G-eSR4-MM850 transceiver modules are supported only in R2612P05 and later. · QSFP-100G-ER4L-WDM1300 transceiver modules are supported only in R2702 and later. |
Table3-14 QSFP28 copper cables available for the QSFP28 ports
Model |
Max transmission distance |
QSFP-100G-D-CAB-1M |
1 m (3.28 ft) |
QSFP-100G-D-CAB-3M |
3 m (9.84 ft) |
QSFP-100G-D-CAB-5M |
5 m (16.40 ft) |
Table3-15 QSFP28 fiber cables available for the QSFP28 ports
QSFP28 fiber cable |
Max transmission distance |
Data rate |
QSFP-100G-D-AOC-7M |
7 m (22.97 ft) |
100 Gbps |
QSFP-100G-D-AOC-10M |
10 m (32.81 ft) |
|
QSFP-100G-D-AOC-20M |
20 m (65.62 ft) |
Figure3-6 QSFP28 copper cable
Figure3-7 QSFP28 fiber cable
|
NOTE: As a best practice, use H3C QSFP28 transceiver modules, QSFP28 cables, QSFP+ transceiver modules, or QSFP+ cables (except for the QSFP+ to 4 × SFP+ cables) for the QSFP28 ports on the switch. The H3C QSFP28 transceiver modules or QSFP28 cables are subject to change over time. For the most up-to-date list of QSFP28 transceiver modules or QSFP28 cables, contact H3C Support or marketing staff. |
1/10GBASE-T autosensing Ethernet port
The S6860-54HT switch provides 1/10GBASE-T autosensing Ethernet ports.
Ports 29 to 36 on the front panel of the S6860-54HT switch cannot operate at 1000 Mbps. You can set the speed of the ports to 10000 Mbps or configure the ports to negotiate a speed with their peers. The negotiated speed can only be 10000 Mbps.
Table3-16 1/10GBASE-T autosensing Ethernet port specifications
Item |
Specification |
Connector type |
RJ-45 |
Port transmission rate |
1/10 Gbps, full duplex, MDI/MDI-X autosensing |
Transmission medium and max transmission distance |
· 55 m (180.45 ft) over category-6 unshielded twisted pair cable · 100 m (328.08 ft) over category-6 shielded twisted pair cable · 100 m (328.08 ft) over category-6A or above twisted pair cable |
Compatible standards |
· IEEE 802.3ab · IEEE 802.3an |
To avoid interference between cables, layer cables as follows:
· Use category-6A or above cables and connectors.
· Do not bundle cables in their first 20 m (65.62 ft).
· Separate power cords and twisted pair cables at and around the distribution frame.
· For ports adjacent to one another on the device, the peer ports on the distribution frame are preferably not adjacent, for example:
¡ If the device connects to one distribution frame, connect port 1 on the device to port 1 on the distribution frame, port 2 on the device to port 3 on the distribution frame, and port 3 on the device to port 5 on the distribution frame.
¡ If the device connects to two distribution frames, connect port 1 on the device to port 1 on distribution frame 1, port 2 on the device to port 1 on distribution frame 2, and port 3 on the device to port 2 on distribution frame 1.
LEDs
System status LED
The system status LED shows the operating status of the switch.
Table3-17 System status LED description
LED mark |
Status |
Description |
SYS |
Steady green |
The switch is operating correctly. |
Flashing green |
The switch is performing power-on self test (POST). |
|
Steady red |
The system has failed POST, or a fault has occurred. |
|
Flashing red |
Some ports have failed POST. |
|
Off |
The switch is powered off or has failed to start up. |
SFP+ port LED
Each SFP+ port has a status LED to show its operating status and activities.
Table3-18 SFP+ port LED description
LED status |
Description |
Steady green |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 10 Gbps. |
Flashing green |
The port is sending or receiving data at 10 Gbps. |
Steady yellow |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 1 Gbps. |
Flashing yellow (3 Hz) |
The port is sending or receiving data at 1 Gbps. |
Off |
No transceiver module or cable has been installed or no link is present on the port. |
QSFP+ port LED
Each QSFP+ port has a status LED to show its operating status and activities.
Table3-19 QSFP+ port LED description
LED status |
Description |
Steady green |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 40 Gbps. |
Flashing green |
The port is sending or receiving data at 40 Gbps. |
Steady yellow |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 10 Gbps. |
Flashing yellow (3 Hz) |
The port is sending or receiving data at 10 Gbps. |
Off |
No transceiver module or cable has been installed or no link is present on the port. |
QSFP28 port LED
Each QSFP28 port has a status LED to show its operating status and activities.
Table3-20 QSFP28 port LED description
LED status |
Description |
Steady green |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 100 Gbps. |
Flashing green |
The port is sending or receiving data at 100 Gbps. |
Steady yellow |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 10/40 Gbps. |
Flashing yellow (3 Hz) |
The port is sending or receiving data at 10/40 Gbps. |
Off |
No transceiver module or cable has been installed or no link is present on the port. |
Management Ethernet port LEDs
The switch provides a LINK/ACT LED for each management Ethernet port. For LED description for the copper management Ethernet port, see Table3-21. For LED description for the fiber management Ethernet port, see Table3-22.
Table3-21 Copper management Ethernet port LED description
LED mark |
Status |
Description |
LINK/ACT |
Steady green |
The port is operating at 10/100/1000 Mbps and a link is present. |
Flashing green |
The port is receiving or sending data. |
|
Off |
No link is present. |
Table3-22 Fiber management Ethernet port LED description
LED mark |
Status |
Description |
LINK/ACT |
Off |
No link is present. |
Steady green |
The port is operating at 100/1000 Mbps and a link is present. |
|
Flashing green |
The port is receiving or sending data. |
1/10GBASE-T autosensing Ethernet port LEDs
Table3-23 1/10GBASE-T autosensing Ethernet port LED description
Status |
Description |
Steady green |
The port has a link and is operating at 10 Gbps. |
Flashing green |
The port is sending or receiving data at 10 Gbps. |
Steady yellow |
The port has a link and is operating at 1 Gbps. |
Flashing yellow |
The port is sending or receiving data at 1 Gbps. |
Off |
No link is present on the port. |
Fan tray alarm LEDs
The LSPM1FANSA and LSPM1FANSB fan trays provide an Alarm LED.
Table3-24 Fan tray alarm LED description
Status |
Description |
On |
The fan tray is faulty. |
Off |
The fan tray is operating correctly. |
4 Cooling system
CAUTION: To guarantee heat dissipation, you must install fan trays of the same model for the switch. |
To dissipate heat timely and ensure system stability, the switch uses the front-rear air aisle cooling system. Consider the site ventilation design when you plan the installation site for the switch.
Table4-1 Cooling system for the switch
Available fan trays |
Airflow direction |
LSPM1FANSA |
From the power supply side to the port side |
LSPM1FANSB |
From the port side to the power supply side |
Figure4-1 Airflow from the power supply side to the port side through the S6860-54HF chassis (with LSPM1FANSA fan trays)
Figure4-2 Airflow from the port side to the power supply side through the S6860-54HF chassis (with LSPM1FANSB fan trays)