H3C S6860 Switch Series Hardware Information and Specifications-6W100

HomeSupportSwitchesS6860 SeriesInstall & UpgradeInstallation GuidesH3C S6860 Switch Series Hardware Information and Specifications-6W100
01-Text
Title Size Download
01-Text 2.80 MB

1 Product models and technical specifications

Product models

H3C S6860 switch series includes the S6860-54HF, S6860-30HF, and S6860-54HT models.

Technical specifications

Table1-1 Technical specifications

Item

S6860-54HF

S6860-30HF

S6860-54HT

Product code

LS-6860-54HF

LS-6860-30HF

LS-6860-54HT

Dimensions (H × W × D)

44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in)

44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in)

44 × 440 × 460 mm (1.73 × 17.32 × 18.11 in)

Weight

≤ 10 kg (22.05 lb)

≤ 10 kg (22.05 lb)

≤ 10 kg (22.05 lb)

Console ports

·     1 × mini USB console port

·     1 × serial console port

·     1 × mini USB console port

·     1 × serial console port

·     1 × mini USB console port

·     1 × serial console port

Management Ethernet ports

·     1 × 10M/100M/1000MBASE-T copper port

·     1 × SFP port

·     1 × 10M/100M/1000MBASE-T copper port

·     1 × SFP port

·     1 × 10M/100M/1000MBASE-T copper port

·     1 × SFP port

USB ports

1

1

1

10GBASE-T Ethernet ports

N/A

N/A

48

NOTE:

Ports 29 to 36 can only operate at 10 Gbps. Ports 1 to 28 and ports 37 to 48 can operate at 10 Gbps or 1 Gbps.

SFP+ ports

48

NOTE:

Ports 29 to 36 can only operate at 10 Gbps. Ports 1 to 28 and ports 37 to 48 can operate at 10 Gbps or 1 Gbps.

24

N/A

QSFP+ ports

Up to 6

Up to 6

Up to 6

QSFP28 ports

Up to 2

Up to 2

Up to 2

Fan tray slots

4

4

5

Power supply slots

2

2

2

Input voltage

PSR250-12A/PSR250-12A1:

·     AC input

¡     Rated voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max voltage: 90 to 290 VAC @ 47 to 63 Hz

·     High-voltage DC input

¡     Rated voltage: 240 VDC

¡     Max voltage: 180 to 320 VDC

PSR450-12A/PSR450-12A1:

·     AC input

¡     Rated voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max voltage: 90 to 290 VAC @ 47 to 63 Hz

·     High-voltage DC input

¡     Rated voltage: 240 VDC

¡     Max voltage: 180 to 320 VDC

PSR450-12AHD:

·     AC input

¡     Rated voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max voltage: 90 to 290 VAC @ 47 to 63 Hz

·     High-voltage DC input

¡     Rated voltage: 240 to 380 VDC

¡     Max voltage: 180 to 400 VDC

PSR450-12D:

·     Rated voltage: –48 to –60 VDC

·     Max voltage: –36 to –72 VDC

PSR450-12A/PSR450-12A1:

·     AC input

¡     Rated voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max voltage: 90 to 290 VAC @ 47 to 63 Hz

·     High-voltage DC input

¡     Rated voltage: 240 VDC

¡     Max voltage: 180 to 320 VDC

PSR450-12AHD:

·     AC input

¡     Rated voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max voltage: 90 to 290 VAC @ 47 to 63 Hz

·     High-voltage DC input

¡     Rated voltage: 240 to 380 VDC

¡     Max voltage: 180 to 400 VDC

PSR450-12D:

·     Rated voltage: –48 to –60 VDC

·     Max voltage: –36 to –72 VDC

Minimum power consumption

(For the power consumption data collection standard, see Table1-2.)

PSR250-12A/PSR250-12A1:

·     Single AC input: 66 W

·     Dual AC inputs: 74 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 68 W

·     Dual AC inputs: 76 W

PSR450-12AHD:

·     Single DC input: 65 W

·     Dual DC inputs: 73 W

PSR450-12D:

·     Single DC input: 68 W

·     Dual DC inputs: 73 W

PSR250-12A/PSR250-12A1:

·     Single AC input: 66 W

·     Dual AC inputs: 74 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 67 W

·     Dual AC inputs: 76 W

PSR450-12AHD:

·     Single DC input: 65 W

·     Dual DC inputs: 73 W

PSR450-12D:

·     Single DC input: 68 W

·     Dual DC inputs: 74 W

PSR450-12A/PSR450-12A1

·     Single AC input: 101 W

·     Dual AC inputs: 108 W

PSR450-12AHD:

·     Single DC input: 95 W

·     Dual DC inputs: 105 W

PSR450-12D:

·     Single DC input: 97 W

·     Dual DC inputs: 104 W

Typical power consumption

(For the power consumption data collection standard, see Table1-2.)

PSR250-12A/PSR250-12A1:

·     Single AC input: 99 W

·     Dual AC inputs: 96 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 90 W

·     Dual AC inputs: 99 W

PSR250-12A/PSR250-12A1:

·     Single AC input: 87 W

·     Dual AC inputs: 86 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 78 W

·     Dual AC inputs: 77 W

PSR450-12A/PSR450-12A1

·     Single AC input: 206 W

·     Dual AC inputs: 212 W

PSR450-12D:

·     Single DC input: 205 W

·     Dual DC inputs: 211 W

Maximum power consumption

(For the power consumption data collection standard, see Table1-2.)

PSR250-12A/PSR250-12A1:

·     Single AC input: 171 W

·     Dual AC inputs: 178 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 169 W

·     Dual AC inputs: 178 W

PSR450-12AHD:

·     Single DC input: 166 W

·     Dual DC inputs: 173 W

PSR450-12D:

·     Single DC input: 169 W

·     Dual DC inputs: 176 W

PSR250-12A/PSR250-12A1:

·     Single AC input: 130 W

·     Dual AC inputs: 134 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 130 W

·     Dual AC inputs: 138 W

PSR450-12AHD:

·     Single DC input: 131 W

·     Dual DC inputs: 139 W

PSR450-12D:

·     Single DC input: 133 W

·     Dual DC inputs: 140 W

PSR450-12A/PSR450-12A1:

·     Single AC input: 255 W

·     Dual AC inputs: 258 W

PSR450-12AHD:

·     Single DC input: 254 W

·     Dual DC inputs: 261 W

PSR450-12D:

·     Single DC input: 259 W

·     Dual DC inputs: 264 W

Chassis leakage current compliance

UL60950-1/EN60950-1/IEC60950-1/GB4943

Melting current of power supply fuse

PSR250-12A/PSR250-12A1:

6.3 A @ 250 VAC
6.3 A @ 250 VDC

PSR450-12A/PSR450-12A1:

10 A @ 250 VAC
10 A @ 310 VDC

PSR450-12D: 20 A @ 125 V

PSR450-12AHD: 10 A @ 420 V

PSR450-12A/PSR450-12A1:

10 A @ 250 VAC
10 A @ 310 VDC

PSR450-12D: 20 A @ 125 V

PSR450-12AHD: 10 A @ 420 V

Sound pressure level at 27°C (80.6°F)

52.5 dB(A)

52.7 dB(A)

52.4 dB(A)

Operating temperature

0°C to 45°C (32°F to 113°F)

Operating humidity

10% RH to 90% RH, noncondensing

Fire resistance compliance

UL60950-1/EN60950-1/IEC60950-1/GB4943

 

Table1-2 Power consumption data collection standard

Item

Static power consumption

Typical power consumption

Maximum power consumption

Configuration

·     Two power supplies

·     No transceiver modules/cables installed in ports

·     Two power supplies

·     Fully configured with copper cables

·     Two power supplies

·     Fully configured with transceiver modules

Load

N/A

50% load

100% load

 

Chassis views

S6860-54HF

Figure1-1 Front panel

(1) SFP+ port LED

(2) SFP+ port

(3) QSFP+ port LED

(4) QSFP28 port LED

(5) QSFP28 port

(6) QSFP+ port

 

Figure1-2 Rear panel

(1) System status LED (SYS)

(2) LINK/ACT LED for the copper management Ethernet port

(3) LINK/ACT LED for the fiber management Ethernet port

(4) Fan tray 1

(5) Fan tray 2

(6) Fan tray 3

(7) Fan tray 4

(8) Power supply 1

(9) Power supply 2

(10) Fiber management Ethernet port

(11) Copper management Ethernet port

(12) Console port

(13) Mini USB console port

(14) USB port

 

An S6860-54HF switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. In Figure1-2, two PSR250-12A power supplies are installed in the power supply slots.

An S6860-54HF switch comes with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure1-2, four LSPM1FANSA fan trays are installed in the fan tray slots.

Figure1-3 Left side panel

(1) Primary grounding point

(2) Auxiliary grounding point

 

S6860-54HT

Figure1-4 Front panel

(1) 1/10GBASE-T autosensing Ethernet port

(2) 1/10GBASE-T autosensing Ethernet port LED

(3) QSFP+ port

(4) QSFP28 port

(5) QSFP28 port LED

(6) QSFP+ port LED

 

Figure1-5 Rear panel

(1) Fiber management Ethernet port

(2) Copper management Ethernet port

(3) Console port

(4) Mini USB console port

(5) Fan tray 1

(6) Fan tray 2

(7) Fan tray 3

(8) Fan tray 4

(9) Fan tray 5

(10) Power supply 1

(11) Power supply 2

(12) USB port

(13) System status LED (SYS)

(14) LINK/ACT LED for the copper management Ethernet port

(15) LINK/ACT LED for the fiber management Ethernet port

 

An S6860-54HT switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. In Figure1-5, two PSR450-12A1 power supplies are installed in the power supply slots.

An S6860-54HT switch comes with the five fan tray slots empty. You must install five fan trays of the same model for the switch. In Figure1-5, five LSPM1FANSB fan trays are installed in the fan tray slots.

Figure1-6 Left side panel

(1) Primary grounding point

(2) Auxiliary grounding point

 

S6860-30HF

Figure1-7 Front panel

(1) SFP+ port LED

(2) SFP+ port

(3) QSFP+ port LED

(4) QSFP28 port LED

(5) QSFP28 port

(6) QSFP+ port

 

Figure1-8 Rear panel

(1) System status LED (SYS)

(2) LINK/ACT LED for the copper management Ethernet port

(3) LINK/ACT LED for the fiber management Ethernet port

(4) Fan tray 1

(5) Fan tray 2

(6) Fan tray 3

(7) Fan tray 4

(8) Power supply 1

(9) Power supply 2

(10) Fiber management Ethernet port

(11) Copper management Ethernet port

(12) Console port

(13) Mini USB console port

(14) USB port

 

An S6860-30HF switch comes with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. In Figure1-2, two PSR250-12A power supplies are installed in the power supply slots.

An S6860-30HF switch comes with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure1-2, four LSPM1FANSA fan trays are installed in the fan tray slots.

Figure1-9 Left side panel

(1) Primary grounding point

(2) Auxiliary grounding point

 


2 FRUs and compatibility matrixes

CAUTION

CAUTION:

·     Select fan trays and power supplies with airflow directions that meet the ventilation requirements at the installation site. As a best practice, make sure the power supplies and fan trays have the same airflow direction.

·     Do not install fan trays of different models on the same switch.

·     Do not install power supplies of different models on the same switch.

 

Table2-1 Compatibility matrix between the FRUs and S6860 switches

FRUs

Part No. in BOM

S6860-54HF

S6860-30HF

S6860-54HT

Power supplies

PSR250-12A

0231A6M0

Yes

Yes

No

PSR250-12A1

0231A8FP

Yes

Yes

No

PSR450-12A

0231A6N9

Yes

Yes

Yes

PSR450-12A1

0231A6NC

Yes

Yes

Yes

PSR450-12AHD

0231A6NA

Yes

Yes

Yes

PSR450-12D

0231A6NB

Yes

Yes

Yes

Fan trays

 

LSPM1FANSA

0231A2VT

Yes

Yes

Yes

LSPM1FANSB

0231A2VU

Yes

Yes

Yes

 

Power supplies

CAUTION

CAUTION:

When the switch has power supplies in redundancy, you can replace a power supply without powering off the switch. Make sure the power supply to be replaced is powered off before you replace it.

 

IMPORTANT

IMPORTANT:

As a best practice, use power supplies of the same model in 1+1 redundancy for power supply.

 

Table2-2 Power supply specifications

Power supply

Specifications

Remarks

PSR250-12A (air intake on power supply panel)

PSR250-12A1 (air exhaust on power supply panel)

·     AC input:

¡     Rated input voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max input voltage: 90 to 290 VAC @ 47 to 63 Hz

¡     Max output power: 250 W

·     DC input:

¡     Rated input voltage: 240 VDC

¡     Max input voltage: 180 to 320 VDC

¡     Max output power: 250 W

For more information about the power supplies, see H3C PSR250-12A & PSR250-12A1 Power Modules User Manual.

PSR450-12A (air intake on power supply panel)

PSR450-12A1 (air exhaust on power supply panel)

·     AC input:

¡     Rated input voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max input voltage: 90 to 290 VAC @ 47 to 63 Hz

¡     Max output power: 450 W

·     DC input:

¡     Rated input voltage: 240 VDC

¡     Max input voltage: 180 to 320 VDC

¡     Max output power: 450 W

For more information about the power supplies, see H3C PSR450 Power Module Series User Manual.

PSR450-12AHD (air exhaust on power supply panel)

·     AC input

¡     Rated voltage: 100 to 240 VAC @ 50/60 Hz

¡     Max voltage: 90 to 290 VAC @ 47 to 63 Hz

¡     Max output power: 450 W

·     High-voltage DC input

¡     Rated voltage: 240 to 380 VDC

¡     Max voltage: 180 to 400 VDC

¡     Max output power: 450 W

PSR450-12D (air exhaust on power supply panel)

·     Rated input voltage: –48 to –60 VDC

·     Max input voltage: –36 to –72 VDC

·     Max output power: 450 W

 

Fan trays

Table2-3 Fan tray specifications

Item

Specifications

LSPM1FANSA

Fans

One 40 × 40 × 28 mm (1.57 × 1.57 × 1.10 in) fan

Fan speed

20000 R.P.M

Max airflow

20 CFM (0.57 m3/min)

Airflow direction

Air intake on fan tray panel

Input voltage

12 V

Maximum power consumption

9.8 W

Documentation reference

H3C LSPM1FANSA & LSPM1FANSB Fan Trays User Guide

LSPM1FANSB

Fans

One 40 × 40 × 28 mm (1.57 × 1.57 × 1.10 in) fan

Fan speed

20000 R.P.M

Max airflow

20 CFM (0.57 m3/min)

Airflow direction

Air exhaust on fan tray panel

Input voltage

12 V

Maximum power consumption

9.8 W

Documentation reference

H3C LSPM1FANSA & LSPM1FANSB Fan Trays User Guide

 


3 Ports and LEDs

Ports

Console port

The switch has two console ports: serial console port and Mini USB console port.

Table3-1 Console port specifications

Item

Console port

Mini USB console port

Connector type

RJ-45

USB mini-Type B

Compliant standard

EIA/TIA-232

USB 2.0

Transmission baud rate

9600 bps (default) to 115200 bps

Services

·     Provides connection to an ASCII terminal.

·     Provides connection to the serial port of a local or remote (through a pair of modems) PC running terminal emulation program.

·     Provides connection to an ASCII terminal.

·     Provides connection to the USB port of a local PC running terminal emulation program.

 

Management Ethernet port

The switch provides a copper and a fiber management Ethernet port.

You can connect this port to a PC or management station for loading and debugging software or remote management.

Table3-2 Copper management Ethernet port specifications

Item

Specification

Connector type

RJ-45

Connector quantity

1

Port transmission rate

10/100/1000 Mbps, half/full duplex

Transmission medium and max transmission distance

100 m (328.08 ft) over category-5 twisted pair cable

Functions and services

Switch software and Boot ROM upgrade, network management

 

Table3-3 Fiber management Ethernet port specifications

Item

Specification

Connector type

LC

Connector quantity

1

Port transmission rate

100/1000 Mbps, full duplex

Transmission medium and max transmission distance

See Table3-4 and Table3-5.

Functions and services

Software upgrade and network management

 

Table3-4 FE SFP transceiver modules

FE SFP transceiver module

Central wavelength (nm)

Connector

Fiber type and diameter (µm)

Max transmission distance

SFP-FE-SX-MM1310-A

1310

LC

Multi-mode, 50/125

2 km (1.24 miles)

Multi-mode, 62.5/125

SFP-FE-LX-SM1310-A

1310

LC

Single-mode, 9/125

15 km (9.32 miles)

SFP-FE-LH40-SM1310

1310

LC

Single-mode, 9/125

40 km (24.86 miles)

 

USB port

The switch has one OHC-compliant USB2.0 port that can upload and download data at a rate up to 480 Mbps. You can use this USB port to access the file system on the Flash of the switch, for example, to upload or download application and configuration files.

 

 

NOTE:

USB devices from different manufacturers vary in compatibilities and drivers. H3C does not guarantee the correct operation of all USB devices on the switch. If a USB device fails to operate on the switch, replace it with one from another manufacturer.

SFP+ port

The S6860-54HF and S6860-30HF switches provide SFP+ ports. The SFP+ ports support Gigabit SFP transceiver modules described in Table3-5, 10-Gigabit SFP+ transceiver modules described in Table3-6, SFP+ copper cables described in Table3-7, and SFP+ fiber cables described in Table3-8.

Ports 29 to 36 on the front panel of the S6860-54HF switch do not support Gigabit SFP copper transceiver modules or Gigabit SFP fiber transceiver modules.

Table3-5 Gigabit SFP transceiver modules available for the SFP+ ports

Gigabit SFP transceiver module

Central wavelength (nm)

Connector

Cable/Fiber type and diameter (µm)

Modal bandwidth (MHz × km)

Max transmission distance

Gigabit SFP copper transceiver module

SFP-GE-T

N/A

RJ-45

Twisted pair cable

N/A

100 m (328.08 ft)

SFP-GE-T-D

N/A

RJ-45

Twisted pair cable

N/A

100 m (328.08 ft)

Gigabit SFP fiber transceiver module

SFP-GE-SX-MM850-A

SFP-GE-SX-MM850-D

850

LC

Multi-mode, 50/125

500

550 m (1804.46 ft)

400

500 m (1640.42 ft)

Multi-mode, 62.5/125

200

275 m (902.23 ft)

160

200 m (656.17 ft)

SFP-GE-LX-SM1310-A

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

Multi-mode, 50/125

500 or 400

550 m (1804.46 ft)

Multi-mode, 62.5/125

500

550 m (1804.46 ft)

SFP-GE-LX-SM1310-D

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-GE-LH40-SM1310

SFP-GE-LH40-SM1310-D

1310

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH40-SM1550

1550

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

SFP-GE-LH80-SM1550

SFP-GE-LH80-SM1550-D

1550

LC

Single-mode, 9/125

N/A

80 km (49.71 miles)

SFP-GE-LH100-SM1550

1550

LC

Single-mode, 9/125

N/A

100 km (62.14 miles)

 

IMPORTANT

IMPORTANT:

·     Installed with an SFP-GE-T or SFP-GE-T-D transceiver module, an SFP+ port can operate only at 1 Gbps.

·     If the switch connects to the peer device through an SFP-GE-T or SFP-GE-T-D transceiver module, packet loss occurs when the switch restarts, because the peer interface comes up before the local interface can come up, As a best practice, configure dynamic link aggregation to avoid such an issue if the switch is connected to the peer device through an aggregate link.

 

Table3-6 10-Gigabit SFP+ transceiver modules available for the SFP+ ports

10-Gigabit SFP+ transceiver module

Central wavelength (nm)

Connector

Fiber type and diameter (µm)

Modal bandwidth (MHz × km)

Max transmission distance

SFP-XG-SX-MM850-A

850

LC

Multi-mode, 50/125

2000

300 m (984.25 ft)

500

82 m (269.03 ft)

400

66 m (216.54 ft)

Multi-mode, 62.5/125

200

33 m (108.27 ft)

160

26 m (85.30 ft)

SFP-XG-LX-SM1310

1310

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-XG-LX-SM1330-BIDI

TX: 1330

RX: 1270

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

SFP-XG-LX-SM1270-BIDI

TX: 1270

RX: 1330

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

 

CAUTION

CAUTION:

·     Use BIDI transceiver modules in matched pair. For example, if one end uses an SFP-XG-LX-SM1270-BIDI transceiver module, the other end must use an SFP-XG-LX-SM1330-BIDI transceiver module.

·     The SFP-XG-LX-SM1270-BIDI and SFP-XG-LX-SM1330-BIDI transceiver modules are supported only in R2612P06 and later.

 

Table3-7 SFP+ copper cables available for the SFP+ ports

SFP+ copper cable

Max transmission distance

LSWM1STK

0.65 m (2.13 ft)

LSWM2STK

1.2 m (3.94 ft)

LSWM3STK

3 m (9.84 ft)

LSTM1STK

5 m (16.40 ft)

 

Table3-8 SFP+ fiber cables available for the SFP+ ports

SFP+ fiber cable

Max transmission distance

Data rate

SFP-XG-D-AOC-7M

7 m (22.97 ft)

10.31 Gbps

SFP-XG-D-AOC-10M

10 m (32.81 ft)

SFP-XG-D-AOC-20M

20 m (65.62 ft)

 

Figure3-1 SFP+ copper cable

(1) Connector

(2) Pull latch

 

Figure3-2 SFP+ fiber cable

SFP+ AOC2副本.png

 

 

NOTE:

·     As a best practice, use H3C SFP transceiver modules, SFP+ transceiver modules, or SFP+ cables for the SFP+ ports on the switch. The H3C SFP transceiver modules, SFP+ transceiver modules, and SFP+ cables are subject to change over time. For the most up-to-date list of SFP transceiver modules, SFP+ transceiver modules, and SFP+ cables, contact H3C Support or marketing staff.

·     For more information about H3C SFP transceiver modules, SFP+ transceiver modules, and SFP+ cables, see H3C Transceiver Modules User Guide.

 

QSFP+ port

The switch provides fixed QSFP+ ports. You can install QSFP+ transceiver modules in Table3-9, QSFP+ cables in Table3-10, and QSFP+ to SFP+ cables in Table3-11 in the QSFP+ ports as needed.

Table3-9 QSFP+ transceiver modules available for the QSFP+ ports

QSFP+ transceiver module

Central wavelength (nm)

Connector

Fiber type and diameter (µm)

Modal bandwidth (MHz × km)

Max transmission distance

QSFP-40G-SR4-MM850

850

MPO

Multi-mode, 50/125

2000

100 m (328.08 ft)

4700

150 m (492.12 ft)

QSFP-40G-CSR4-MM850

850

MPO

Multi-mode, 50/125

2000

300 m (984.25 ft)

4700

400 m (1312.33 ft)

QSFP-40G-BIDI-SR-MM850

850

LC

Multi-mode, 50/125

2000

100 m (328.08 ft)

4700

150 m (492.12 ft)

QSFP-40G-BIDI-WDM850

Four lanes:

·     850

·     880

·     910

·     940

LC

Multi-mode, 50/125

2000

240 m (787.40 ft)

4700

350 m (1148.29 ft)

QSFP-40G-LR4-WDM1300

Four lanes:

·     1271

·     1291

·     1311

·     1331

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

QSFP-40G-LR4L-WDM1300

Four lanes:

·     1271

·     1291

·     1311

·     1331

LC

Single-mode, 9/125

N/A

2 km (1.24 miles)

QSFP-40G-LR4-PSM1310

1310

MPO

Single-mode, 9/125

N/A

10 km (6.21 miles)

 

IMPORTANT

IMPORTANT:

QSFP-40G-BIDI-WDM850 transceiver modules are supported only in R2612P06 and later.

 

Table3-10 QSFP+ cables available for the QSFP+ ports

QSFP+ cable

Max transmission distance

LSWM1QSTK0

1 m (3.28 ft)

LSWM1QSTK1

3 m (9.84 ft)

LSWM1QSTK2

5 m (16.40 ft)

 

Table3-11 QSFP+ to SFP+ cables available for the QSFP+ ports

QSFP+ to SFP+ cable

Max transmission distance

LSWM1QSTK3

1 m (3.28 ft)

LSWM1QSTK4

3 m (9.84 ft)

LSWM1QSTK5

5 m (16.40 ft)

 

Table3-12 QSFP+ fiber cables available for the QSFP+ ports

QSFP+ fiber cable

Max transmission distance

Data rate

QSFP-40G-D-AOC-3M

3 m (9.84 ft)

40 Gbps

QSFP-40G-D-AOC-7M

7 m (22.97 ft)

QSFP-40G-D-AOC-10M

10 m (32.81 ft)

QSFP-40G-D-AOC-20M

20 m (65.62 ft)

 

Figure3-3 QSFP+ cable

(1) Connector

(2) Pull latch

 

Figure3-4 QSFP+ to SFP+ cable

(1) QSFP+ module

(2) QSFP+ side pull latch

(3) SFP+ side pull latch

(4) SFP+ module

 

Figure3-5 QSFP+ fiber cable

QSFP+ AOC.png

 

IMPORTANT

IMPORTANT:

You can use a QSFP-40G-SR4-MM850 or QSFP-40G-CSR4-MM850 transceiver module to connect a QSFP+ port to four SFP+ ports. The QSFP+ transceiver module and SFP+ transceiver modules to be connected must be the same in specifications, including central wavelength and fiber type.

 

 

NOTE:

·     As a best practice, use H3C QSFP+ transceiver modules, QSFP+ cables, or QSFP+ to 4 × SFP+ cables for the QSFP+ ports on the switch. The H3C QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to 4 × SFP+ cables available for the interface cards are subject to change over time. For the most recent list of QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to 4 × SFP+ cables available for the interface cards, contact H3C Support or marketing staff.

·     For more information about H3C QSFP+ transceiver modules, QSFP+ cables, and QSFP+ to 4 × SFP+ cables, see H3C Transceiver Modules User Guide.

 

QSFP28 port

The switch provides QSFP28 ports. The QSFP28 ports are 40GE ports by default. To change the ports to 100GE ports, execute the related command from the CLI. For more information, see Ethernet interface commands in H3C S6860 Switch Series Command References.

When a QSFP28 port operates as a 40GE port, the QSFP+ modules in Table3-9, QSFP+ cables in Table3-10, QSFP+ to SFP+ cables in Table3-11, and QSFP+ fiber cables in Table3-12 are available for the QSFP28 port.

A QSFP28 port does not support one-to-four splitting when it operates as a 100GE port. When a QSFP28 port operates as a 100GE port, the QSFP28 modules in Table3-13, QSFP28 copper cables in Table3-14, QSFP+ modules in Table3-9, QSFP+ cables in Table3-10, and QSFP+ fiber cables in Table3-12 are available for the QSFP28 port.

Table3-13 QSFP28 transceiver modules available for the QSFP28 ports

Model

Central wavelength (nm)

Connector

Cable/Fiber type and diameter (µm)

Modal bandwidth (MHz × km)

Max transmission distance

QSFP-100G-SR4-MM850

QSFP-100G-SR4-MM850-A

850

MPO (PC polished, 12-fiber)

Multi-mode, 50/125

2000

70 m (229.66 ft)

4700

100 m (328.08 ft)

QSFP-100G-eSR4-MM850

850

MPO (PC polished, 12-fiber)

Multi-mode, 50/125

4700

300 m (984.25 ft)

QSFP-100G-BIDI-MM850 (end of sale)

Two lanes:

·     855

·     908

LC

Multi-mode, 50/125

2000

70 m (229.66 ft)

4700

100 m (328.08 ft)

QSFP-100G-PSM4-SM1310

1310

MPO (APC polished, 12-fiber)

Single-mode, 9/125

N/A

0.5 km (0.31 miles)

QSFP-100G-LR4-WDM1300

QSFP-100G-LR4-WDM1300-A

Four lanes:

·     1295.56

·     1300.05

·     1304.58

·     1309.14

LC

Single-mode, 9/125

N/A

10 km (6.21 miles)

QSFP-100G-LR4L-WDM1300

Four lanes:

·     1271

·     1291

·     1311

·     1331

LC

Single-mode, 9/125

N/A

2 km (1.24 miles)

QSFP-100G-CWDM4-SM1300-A

Four lanes:

·     1271

·     1291

·     1311

·     1331

LC

Single-mode, 9/125

N/A

2 km (1.24 miles)

QSFP-100G-ER4L-WDM1300

Four lanes:

·     1295.56

·     1300.05

·     1304.58

·     1309.14

LC

Single-mode, 9/125

N/A

40 km (24.86 miles)

QSFP-100G-SWDM4-MM850

Four lanes:

·     850

·     880

·     910

·     940

LC

Multi-mode, 50/125

2000

75 m (246.06 ft)

4700

100 m (328.08 ft)

 

IMPORTANT

IMPORTANT:

·     QSFP-100G-SWDM4-MM850 transceiver modules are supported only in R2612P01 and later.

·     The QSFP-100G-BIDI-MM850 and QSFP-100G-eSR4-MM850 transceiver modules are supported only in R2612P05 and later.

·     QSFP-100G-ER4L-WDM1300 transceiver modules are supported only in R2702 and later.

 

Table3-14 QSFP28 copper cables available for the QSFP28 ports

Model

Max transmission distance

QSFP-100G-D-CAB-1M

1 m (3.28 ft)

QSFP-100G-D-CAB-3M

3 m (9.84 ft)

QSFP-100G-D-CAB-5M

5 m (16.40 ft)

 

Table3-15 QSFP28 fiber cables available for the QSFP28 ports

QSFP28 fiber cable

Max transmission distance

Data rate

QSFP-100G-D-AOC-7M

7 m (22.97 ft)

100 Gbps

QSFP-100G-D-AOC-10M

10 m (32.81 ft)

QSFP-100G-D-AOC-20M

20 m (65.62 ft)

 

Figure3-6 QSFP28 copper cable

JG326A_HP X241 40G QSFP QSFP 1m Direct Attach Copper Cable.png

 

Figure3-7 QSFP28 fiber cable

QSFP28光缆.PNG

 

 

NOTE:

As a best practice, use H3C QSFP28 transceiver modules, QSFP28 cables, QSFP+ transceiver modules, or QSFP+ cables (except for the QSFP+ to 4 × SFP+ cables) for the QSFP28 ports on the switch. The H3C QSFP28 transceiver modules or QSFP28 cables are subject to change over time. For the most up-to-date list of QSFP28 transceiver modules or QSFP28 cables, contact H3C Support or marketing staff.

 

1/10GBASE-T autosensing Ethernet port

The S6860-54HT switch provides 1/10GBASE-T autosensing Ethernet ports.

Ports 29 to 36 on the front panel of the S6860-54HT switch cannot operate at 1000 Mbps. You can set the speed of the ports to 10000 Mbps or configure the ports to negotiate a speed with their peers. The negotiated speed can only be 10000 Mbps.

Table3-16 1/10GBASE-T autosensing Ethernet port specifications

Item

Specification

Connector type

RJ-45

Port transmission rate

1/10 Gbps, full duplex, MDI/MDI-X autosensing

Transmission medium and max transmission distance

·     55 m (180.45 ft) over category-6 unshielded twisted pair cable

·     100 m (328.08 ft) over category-6 shielded twisted pair cable

·     100 m (328.08 ft) over category-6A or above twisted pair cable

Compatible standards

·     IEEE 802.3ab

·     IEEE 802.3an

 

To avoid interference between cables, layer cables as follows:

·     Use category-6A or above cables and connectors.

·     Do not bundle cables in their first 20 m (65.62 ft).

·     Separate power cords and twisted pair cables at and around the distribution frame.

·     For ports adjacent to one another on the device, the peer ports on the distribution frame are preferably not adjacent, for example:

¡     If the device connects to one distribution frame, connect port 1 on the device to port 1 on the distribution frame, port 2 on the device to port 3 on the distribution frame, and port 3 on the device to port 5 on the distribution frame.

¡     If the device connects to two distribution frames, connect port 1 on the device to port 1 on distribution frame 1, port 2 on the device to port 1 on distribution frame 2, and port 3 on the device to port 2 on distribution frame 1.

LEDs

System status LED

The system status LED shows the operating status of the switch.

Table3-17 System status LED description

LED mark

Status

Description

SYS

Steady green

The switch is operating correctly.

Flashing green

The switch is performing power-on self test (POST).

Steady red

The system has failed POST, or a fault has occurred.

Flashing red

Some ports have failed POST.

Off

The switch is powered off or has failed to start up.

 

SFP+ port LED

Each SFP+ port has a status LED to show its operating status and activities.

Table3-18 SFP+ port LED description

LED status

Description

Steady green

A transceiver module or cable has been correctly installed. The port has a link and is operating at 10 Gbps.

Flashing green

The port is sending or receiving data at 10 Gbps.

Steady yellow

A transceiver module or cable has been correctly installed. The port has a link and is operating at 1 Gbps.

Flashing yellow (3 Hz)

The port is sending or receiving data at 1 Gbps.

Off

No transceiver module or cable has been installed or no link is present on the port.

 

QSFP+ port LED

Each QSFP+ port has a status LED to show its operating status and activities.

Table3-19 QSFP+ port LED description

LED status

Description

Steady green

A transceiver module or cable has been correctly installed. The port has a link and is operating at 40 Gbps.

Flashing green

The port is sending or receiving data at 40 Gbps.

Steady yellow

A transceiver module or cable has been correctly installed. The port has a link and is operating at 10 Gbps.

Flashing yellow (3 Hz)

The port is sending or receiving data at 10 Gbps.

Off

No transceiver module or cable has been installed or no link is present on the port.

 

QSFP28 port LED

Each QSFP28 port has a status LED to show its operating status and activities.

Table3-20 QSFP28 port LED description

LED status

Description

Steady green

A transceiver module or cable has been correctly installed. The port has a link and is operating at 100 Gbps.

Flashing green

The port is sending or receiving data at 100 Gbps.

Steady yellow

A transceiver module or cable has been correctly installed. The port has a link and is operating at 10/40 Gbps.

Flashing yellow (3 Hz)

The port is sending or receiving data at 10/40 Gbps.

Off

No transceiver module or cable has been installed or no link is present on the port.

 

Management Ethernet port LEDs

The switch provides a LINK/ACT LED for each management Ethernet port. For LED description for the copper management Ethernet port, see Table3-21. For LED description for the fiber management Ethernet port, see Table3-22.

Table3-21 Copper management Ethernet port LED description

LED mark

Status

Description

LINK/ACT

Steady green

The port is operating at 10/100/1000 Mbps and a link is present.

Flashing green

The port is receiving or sending data.

Off

No link is present.

 

Table3-22 Fiber management Ethernet port LED description

LED mark

Status

Description

LINK/ACT

Off

No link is present.

Steady green

The port is operating at 100/1000 Mbps and a link is present.

Flashing green

The port is receiving or sending data.

 

1/10GBASE-T autosensing Ethernet port LEDs

Table3-23 1/10GBASE-T autosensing Ethernet port LED description

Status

Description

Steady green

The port has a link and is operating at 10 Gbps.

Flashing green

The port is sending or receiving data at 10 Gbps.

Steady yellow

The port has a link and is operating at 1 Gbps.

Flashing yellow

The port is sending or receiving data at 1 Gbps.

Off

No link is present on the port.

 

Fan tray alarm LEDs

The LSPM1FANSA and LSPM1FANSB fan trays provide an Alarm LED.

Table3-24 Fan tray alarm LED description

Status

Description

On

The fan tray is faulty.

Off

The fan tray is operating correctly.

 


4 Cooling system

CAUTION

CAUTION:

To guarantee heat dissipation, you must install fan trays of the same model for the switch.

 

To dissipate heat timely and ensure system stability, the switch uses the front-rear air aisle cooling system. Consider the site ventilation design when you plan the installation site for the switch.

Table4-1 Cooling system for the switch

Available fan trays

Airflow direction

LSPM1FANSA

From the power supply side to the port side

LSPM1FANSB

From the port side to the power supply side

 

Figure4-1 Airflow from the power supply side to the port side through the S6860-54HF chassis (with LSPM1FANSA fan trays)

 

Figure4-2 Airflow from the port side to the power supply side through the S6860-54HF chassis (with LSPM1FANSB fan trays)

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网