1 Preparing for installation· 1

Safety recommendations· 1

Safety symbols· 1

General safety recommendations· 1

Electrical safety· 2

Laser safety· 2

Handling safety· 2

Examining the installation site· 3

Weight support 3

Temperature and humidity· 3

Cleanliness· 3

Cooling system·· 4

ESD prevention· 5

EMI 5

Lightning protection· 5

Power supply· 6

Installation tools· 6

Accessories· 6

Pre-installation checklist 6

2 Installing the firewall 9

Installation flow· 9

Mounting the firewall on a workbench· 10

Installing the firewall in a standard 19-inch rack· 10

Rack-mounting the firewall by using front mounting brackets· 11

Rack-mounting the firewall by using front and rear mounting brackets· 12

Grounding the firewall 15

Grounding the firewall with a grounding strip· 16

Grounding the firewall with the grounding terminal on the rack· 16

Installing a power supply· 17

Installing an interface module· 18

Installing a drive· 19

Installing a drive for an F1000-AI-15 firewall 19

Installing a drive for other firewalls than the F1000-AI-15· 20

Connecting Ethernet cables· 20

Connecting a copper Ethernet port 20

Connecting a fiber port 21

Connecting power cords· 22

Connecting an AC power cord· 22

Connecting a DC power cord· 23

Verifying the installation· 24

3 Accessing the firewall 3-25

Starting the firewall 3-25

Pre-start checking· 3-25

Starting the firewall and observing the initial startup conditions· 3-25

Logging in to the firewall 3-26

Logging in from the Web interface· 3-26

Logging in from the console port 3-27

Logging in through Telnet 3-27

4 Hardware replacement 4-29

Replacing a power supply· 4-29

Replacing an interface module· 4-29

Replacing a drive· 4-30

Replacing a drive for an F1000-AI-15 firewall 4-30

Replacing a drive for the F1000-AI-05, F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65 and F1000-AI-75 firewalls  4-31

Replacing a transceiver module· 4-31

5 Hardware management and maintenance· 5-33

Displaying detailed information about the firewall 5-33

Displaying the software and hardware version information for the firewall 5-33

Displaying the electrical label information for the firewall 5-34

Displaying the CPU usage of the firewall 5-35

Displaying the memory usage of the firewall 5-35

Displaying the temperature information of the firewall 5-36

Displaying the operational statistics of the firewall 5-37

Displaying transceiver module information· 5-37

Rebooting the firewall 5-38

6 Troubleshooting· 6-40

Power supply failure· 6-40

Configuration terminal display issue· 6-40

Password loss· 6-40

Cooling system failure· 6-41

Software loading failure· 6-41

7 Appendix A  Chassis views and technical specifications· 6-42

Chassis views· 6-42

F1000-AI-05· 6-42

F1000-AI-15· 6-42

F1000-AI-25/F1000-AI-35/F1000-AI-55· 6-43

F1000-AI-65/F1000-AI-75· 6-44

Interface modules· 6-45

NSQM1GT4PFC· 6-46

NSQM1GP4FBA· 6-46

NS-NIM-TG6A· 6-46

Drives· 6-47

Network data encryption modules· 6-47

Power supplies· 6-48

AC power supplies· 6-48

DC power supplies· 6-48

Dimensions and weights· 6-49

Chassis· 6-49

Interface modules· 6-49

Network data encryption modules· 6-50

Drives· 6-50

Storage media· 6-50

Power consumption· 6-50

Chassis· 6-51

Interface modules· 6-51

Network data encryption modules· 6-51

Drives· 6-51

Power supply specifications· 6-51

Port specifications· 6-52

Console port 6-52

GE copper port 6-52

GE fiber port 6-53

10 GE fiber port 6-53

8 Appendix B  LEDs· 6-54

F1000-AI-05· 6-54

F1000-AI-15· 6-55

F1000-AI-25/F1000-AI-35/F1000-AI-55/F1000-AI-65/F1000-AI-75· 6-56

9 Appendix C  Cables· 6-57

Console cable· 6-57

Ethernet twisted pair cable· 6-58

Introduction· 6-58

Making an Ethernet twisted pair cable· 6-61

Optical fiber 6-61

 


1 Preparing for installation

This document is applicable to the following firewall models:

·     F1000-AI-05

·     F1000-AI-15

·     F1000-AI-25

·     F1000-AI-35

·     F1000-AI-55

·     F1000-AI-65

·     F1000-AI-75

Safety recommendations

To avoid any equipment damage or bodily injury, read the following safety recommendations before installation. Note that the recommendations do not cover every possible hazardous condition.

Safety symbols

When reading this document, note the following symbols:

WARNING WARNING means an alert that calls attention to important information that if not understood or followed can result in personal injury.

CAUTION CAUTION means an alert that calls attention to important information that if not understood or followed can result in data loss, data corruption, or damage to hardware or software.

General safety recommendations

·     Do not place the firewall on an unstable case or desk. The firewall might be severely damaged in case of a fall.

·     Make sure the ground is dry and flat and anti-slip measures are in place.

·     Keep the chassis and installation tools away from walk areas.

·     Keep the chassis clean and dust-free.

·     Do not place the firewall near water or in a damp environment. Prevent water or moisture from entering the firewall chassis.

·     Ensure good ventilation of the equipment room and keep the air inlet and outlet vents of the firewall free of obstruction.

·     Make sure the operating voltage is in the required range.

·     Use a screwdriver, rather than your fingers, to fasten screws.

·     Stack devices according to the sizes of and packing symbols on the packages.

Figure1-1 Packing symbols

Symbol

Description

Stored with a maximum stack of n units.

Transported and stored with the arrows up.

Transported and stored with care.

Transported and stored avoiding humidity, rains and wet floor.

 

Electrical safety

·     Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds.

·     Locate the emergency power-off switch in the room before installation. Shut the power off at once in case accident occurs.

·     Do not work alone when the firewall has power.

·     Always verify that the power has been disconnected.

Laser safety

WARNING

WARNING!

Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare into beams or view directly with optical instruments when the firewall is operating.

 

The firewall is a Class 1 laser device.

·     Before you disconnect the fiber connector, execute the shutdown command in interface view to disable the optical source.

·     Install dust caps to disconnected optical fiber connectors and ports on disconnected transceiver modules to avoid damage caused by built-up dust.

·     Insert a dust plug into empty fiber ports.

Handling safety

When you move the firewall, follow these guidelines:

·     Move and unpack the firewall carefully to avoid firewall damage.

·     Unpack the firewall at least half an hour and power on the firewall at least two hours after you move it from a place below 0°C (32°F) to the equipment room. This prevents condensation and even damage to the firewall.

·     Use a safety hand truck when you move multiple firewalls.

·     Before you move the firewall, remove all cables and mounting brackets.

·     For long-distance transportation, remove all the removable components, such as power supplies and interface modules, and package them separately, and install the filler panels supplied with the firewall. For short-distance transportation, make sure all the removable components are securely seated in the slots and the screws are fastened.

·     When you move or lift the firewall chassis, support the bottom of the chassis, rather than holding any removable component. Make sure the accessories of the firewall are not lost or damaged during firewall moving.

Examining the installation site

The firewall can only be used indoors. To make sure the firewall operates correctly and to prolong its service lifetime, the installation site must meet the following requirements.

Weight support

Make sure the floor can support the total weight of the rack, chassis, modules, and all other components. For more information, see "Dimensions and weights."

Temperature and humidity

Maintain appropriate temperature and humidity in the equipment room.

·     Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical property change of materials, and metal corrosion.

·     Lasting low relative humidity can cause washer contraction and ESD and bring problems including loose captive screws and circuit failure.

·     High temperature can accelerate the aging of insulation materials and significantly lower the reliability and lifespan of the firewall.

For the temperature and humidity requirements of the firewall, see Table1-1.

Table1-1 Temperature/humidity requirements

Temperature

Relative humidity

·     Operating:

¡     Without drives: 0°C to 45°C (32°F to 113°F)

¡     With drives: 5°C to 40°C (41°F to 104°F)

·     Storage: –40°C to +70°C (–40°F to +158°F)

·     Operating:

¡     Without drives: 5% to 95%, noncondensing

¡     With drives: 10% to 90%, noncondensing

·     Storage: 5% to 95%, noncondensing

 

Cleanliness

Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of metal components and contact points, especially when indoor relative humidity is low. In the worst case, electrostatic adsorption can cause communication failure.

Table1-2 Dust concentration limit in the equipment room

Substance

Concentration limit (particles/m3)

Dust particles

≤ 3 × 104 (No visible dust on desk in three days)

NOTE:

Dust particle diameter ≥ 5 µm

 

The equipment room must also meet strict limits on salts, acids, and sulfides to eliminate corrosion and premature aging of components, as shown in Table1-3.

Table1-3 Harmful gas limits in an equipment room

Gas

Max. (mg/m3)

SO2

0.2

H2S

0.006

NH3

0.05

Cl2

0.01

NO2

0.04

 

Cooling system

For adequate cooling of the firewall, follow these guidelines:

·     Plan the firewall installation position for the airflow direction of the firewall to match the ventilation designs at the installation site.

·     Reserve a minimum clearance of 80 mm (3.15 in) around the inlet and outlet air vents.

·     Make sure the installation site has a good cooling system.

·     When installing the firewall in a standard 19-inch rack, reserve a distance of 1U (44.45 mm, or 1.75 in) between the chassis and other devices.

The F1000-AI-05 firewall cools itself naturally.

The F1000-AI-15 firewall provides front side-intake and rear side-exhaust airflow for heat dissipation.

The F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, and F1000-AI-75 firewalls provide left side-intake and right side-exhaust airflow for heat dissipation.

 

Figure1-2 Airflow through the F1000-AI-15 firewall chassis

 

Figure1-3 Airflow through the F1000-AI-25/F1000-AI-35/F1000-AI-55/F1000-AI-65/F1000-AI-75 firewall chassis

 

ESD prevention

To prevent electrostatic discharge (ESD), follow these guidelines:

·     Make sure the firewall, the workbench, and the rack are reliably grounded.

·     Take dust-proof measures for the equipment room. For more information, see "Cleanliness."

·     Maintain the humidity and temperature at an acceptable level. For more information, see "Temperature and humidity."

·     Put the removed interface modules away on an ESD workbench, with the PCB upward, or put them in ESD bags for future use.

·     Always wear ESD clothing, ESD gloves, and an ESD wrist strap.

EMI

All electromagnetic interference (EMI) sources, from outside or inside of the firewall and application system, adversely affect the firewall in the following ways:

·     A conduction pattern of capacitance coupling.

·     Inductance coupling.

·     Electromagnetic wave radiation.

·     Common impedance (including the grounding system) coupling.

To prevent EMI, use the following guidelines:

·     If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE) to filter interference from the power grid.

·     Keep the firewall far away from radio transmitting stations, radar stations, and high-frequency devices.

·     Use electromagnetic shielding, for example, shielded interface cables, when necessary.

·     To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning strikes, route interface cables only indoors. If part of the network cable of an Ethernet port must be routed outdoors, connect a lightning arrester to the cable before you plug the cable into the port.

Lightning protection

To protect the firewall from lightning better, follow these guidelines:

·     Make sure the grounding cable of the chassis is reliably grounded.

·     Make sure the grounding terminal of the AC power receptacle is reliably grounded.

·     Install a lightning arrester at the input end of the power supply to enhance the lightning protection capability of the power supply.

Power supply

Verify that the power system at the installation site meets the requirements of the power supplies, including the input method and rated input voltage. For more information, see "Appendix A Chassis views and technical specifications."

Installation tools

All installation tools are user supplied.

 

Flat-head screwdriver

Phillips screwdriver

Needle-nose pliers

Marker

Diagonal pliers

ESD wrist strap

Wire stripper

Crimping tool

 

Accessories

F1000-AI-05, F1000-AI-15 mounting bracket

F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, F1000-AI-75 mounting brackets (including M4 shoulder screws)

Cage nut

M4 screw

M6 screw

Rubber feet

Grounding cable

Console cable

 

 

Power cord

Power cord retainer

 

 

 

Pre-installation checklist

Table1-4 Checklist before installation

Item

Requirements

Result

Installation site

Ventilation

·     There is a minimum clearance of 80 mm (3.15 in) around the inlet and outlet air vents for heat dissipation of the firewall chassis.

·     A good ventilation system is available at the installation site.

·     When installing the firewall in a standard 19-inch rack, reserve a distance of 1U (44.45 mm, or 1.75 in) between the chassis and other devices.

 

Temperature

·     Operating:

¡     Without drives: 0°C to 45°C (32°F to 113°F)

¡     With drives: 5°C to 40°C (41°F to 104°F)

·     Storage: –40°C to +70°C (–40°F to +158°F)

 

Relative humidity

·     Operating:

¡     Without drives: 5% RH to 95% RH, noncondensing

¡     With drives: 10% RH to 90% RH, noncondensing

·     Storage: 5% RH to 95% RH, noncondensing

 

Cleanness

·     Dust concentration ≤ 3 × 104 particles/m3

·     No dust on desk within three days

 

ESD prevention

·     The equipment, workbench, and rack are reliably grounded.

·     The equipment room is dust-proof.

·     The humidity and temperature are at an acceptable level.

·     Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded when installing removable components.

·     Put the removed interface modules away on an ESD workbench, with the PCB upward, or put them in ESD bags for future use.

·     Touch only the edges, instead of electronic components when observing or moving a removed interface module.

 

EMI prevention

·     Take effective measures to protect the power system from the power grid system.

·     Separate the protection ground of the firewall from the grounding device or lightning protection grounding device as far as possible.

·     Keep the firewall far away from radio stations, radar and high-frequency devices working in high current.

·     Use electromagnetic shielding when necessary.

 

Lightning protection

·     The grounding cable of the chassis is reliably grounded.

·     The grounding terminal of the AC power receptacle is reliably grounded.

·     (Optional.) A power lightning arrester is installed.

 

Electricity safety

·     Equip a UPS.

·     Locate the power switch in the equipment room. In case of emergency during operation, switch off the power switch.

 

Rack-mounting requirements

·     Make sure the cabinet is equipped with a good ventilation system.

·     The rack is sturdy enough to support the weight of the firewall and installation accessories.

·     The size of the rack is appropriate for the firewall.

·     The front and rear of the rack are a minimum of 0.8 m (31.50 in) away from walls or other devices.

 

Safety precautions

·     The firewall is far away from any moist area and heat source.

·     The emergency power switch in the equipment room is located.

 

Tools and accessories

·     Installation accessories supplied with the firewall

·     User-supplied tools

 

Reference

·     Documents shipped with the firewall

·     Online documents

 

 


2 Installing the firewall

WARNING

WARNING!

Keep the tamper-proof seal on a mounting screw on the chassis cover intact, and if you want to open the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence.

 

The installation procedure is similar for the F1000-AI-05, F1000-AI-15, F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, and F1000-AI-75 firewalls.

The firewall appearance varies by model. The following figures are for illustration only.

Installation flow

Table2-1 Installation flow for the firewall

Step

Description

1.     Start

Before installation, make sure all requirements on the checklist are met and the firewall is powered off.

2.     Mounting the firewall on a workbench

Verify that the workbench is sturdy and reliably grounded. Ensure a minimum clearance of 80 mm (3.15 in) around the air inlet and outlet vents of the chassis.

3.     Installing the firewall in a standard 19-inch rack

To avoid bodily injury and device damage, use a minimum of two people to rack-mount the firewall.

4.     Grounding the firewall

Before installation, make sure the firewall and rack are grounded correctly and you wear an ESD wrist strap.

5.     Installing a power supply

Before you install a power supply, make sure the power supply is not connected to any power source and the grounding cable of the firewall is connected reliably.

6.     Installing an interface module

Install compatible interface modules on the firewall.

7.     Installing a drive

Install compatible drives on the firewall.

8.     Connecting Ethernet cables

The firewall provides various ports. Choose compatible transceiver modules and cables as required. To avoid bodily injury or device damage, read the restrictions and guidelines carefully before connection.

9.     Connecting power cords

Connect compatible power cords to the power supplies.

10.     Verifying the installation

Verify that the firewall is installed securely and reliably grounded, and that the power supplies are as required.

 

Mounting the firewall on a workbench

IMPORTANT

IMPORTANT:

·     Ensure good ventilation and a minimum clearance of 80 mm (3.15 in) around the chassis for heat dissipation.

·     Avoid placing heavy objects on the firewall.

·     To stack firewalls, make sure a minimum distance of 15 mm (0.59 in) is available between two adjacent firewalls.

 

If a standard 19-inch rack is not available, you can place the firewall on a workbench.

To mount the firewall on a workbench:

1.     Verify that the workbench is sturdy and reliably grounded.

2.     Place the firewall upside down on the workbench and clean the four round holes in the chassis bottom with a dry cloth.

3.     Attach the four rubber feet to the round holes in the chassis bottom.

4.     Place the firewall with upside up on the workbench.

Figure2-1 Mounting the firewall on a workbench

 

Installing the firewall in a standard 19-inch rack

WARNING

WARNING!

To avoid bodily injury and device damage, use a minimum of two persons to rack-mount the firewall.

 

CAUTION

CAUTION:

For adequate heat dissipation, ensure a minimum clearance of 80 mm (3.15 in) around the air inlet and outlet vents of the chassis and a distance of 1U (44.45 mm, or 1.75 in) between the chassis and other devices in the rack.

 

Rack-mounting the firewall by using front mounting brackets

The F1000-AI-05 and F1000-AI-15 firewalls support this installation method.

To install the firewall in a standard 19-inch rack by using front mounting brackets:

1.     Wear an ESD wrist strap and make sure the wrist strap makes good skin contact and is reliably grounded.

2.     Unpack the firewall and accessories.

3.     Mark the cage nut installation positions on the rack posts by using the mounting brackets.

4.     Install cage nuts.

Figure2-2 Installing cage nuts

 

5.     Attach the front mounting brackets to both sides of the firewall with M4 screws provided with the firewall.

Figure2-3 Attaching the front mounting brackets to the firewall

 

6.     Mount the firewall in the rack. Use M6 screws to secure the mounting brackets to the front rack posts.

Figure2-4 Mounting the firewall in the rack

 

Rack-mounting the firewall by using front and rear mounting brackets

The F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, and F1000-AI-75 firewalls support this installation method.

To install the firewall in a standard 19-inch rack:

1.     Wear an ESD wrist strap and make sure the wrist strap makes good skin contact and is reliably grounded.

2.     Unpack the firewall and accessories.

3.     Mark the cage nut installation positions on the rack posts by using the mounting brackets.

4.     Install cage nuts.

Figure2-5 Installing cage nuts

 

5.     Attach the front mounting brackets and shoulder screws to both sides of the firewall with M4 screws provided with the firewall.

Figure2-6 Attaching mounting brackets and shoulder screws to the firewall

 

6.     Attach the rear mounting brackets to the rear rack posts. The rear mounting brackets can be attached to the rear rack posts with the wide flange inside or outside the rack.

Table2-2 Installation methods for rear mounting brackets

Distance between the front and rear rack posts

Rear mounting bracket installation method

405 to 569 mm (15.94 to 22.40 in)

With the wide flange inside the rack.

247 to 411 mm (9.72 to 16.18 in)

With the wide flange outside the rack.

Caution:

To prevent the rear mounting brackets from obstructing the closing of the rack door, ensure a distance greater than 153 mm (6.02 in) between the rear rack posts and the interior side of the rack door.

 

Figure2-7 Attaching the rear mounting brackets to the rear rack posts (with the wide flange inside the rack)

 

Figure2-8 Attaching the rear mounting brackets to the rear rack posts (with the wide flange outside the rack)

 

7.     Mount the firewall in the rack. Use M6 screws to secure the mounting brackets to the front rack posts and make sure the shoulder screws rest firmly on the upper edge of the rear mounting brackets.

Figure2-9 Mounting the firewall in the rack (with the wide flange of the rear mounting brackets inside the rack)

 

Figure2-10 Mounting the firewall in the rack (with the wide flange of the rear mounting brackets outside the rack)

 

Grounding the firewall

WARNING

WARNING!

·     Correctly connecting the firewall grounding cable is crucial to lightning protection and EMI protection.

·     Do not connect the firewall grounding cable to a fire main or lightning rod.

 

You can ground the firewall in one of the following ways, depending on the grounding conditions available at the installation site.

Grounding the firewall with a grounding strip

If a grounding strip is available at the installation site, connect the grounding cable through the grounding strip.

To connect the grounding cable:

1.     Remove the grounding screw from the firewall chassis.

2.     Attach the grounding screw to the ring terminal of the grounding cable.

3.     Use a Phillips screwdriver to fasten the grounding screw into the grounding hole on the firewall.

4.     Remove the hex nut from the grounding strip.

5.     Use a pair of needle-nose pliers to bend a hook at the other end of the grounding cable. Attach the hook to the grounding point, and secure the hook with a screw.

Figure2-11 Grounding the firewall with a grounding strip

 

Grounding the firewall with the grounding terminal on the rack

1.     Remove the grounding screw from the firewall chassis.

2.     Attach the grounding screw to the ring terminal of the grounding cable.

3.     Use a Phillips screwdriver to fasten the grounding screw into the grounding hole on the firewall.

4.     Remove the grounding screw from the grounding point on the rack.

5.     Use a pair of needle-nose pliers to bend a hook at the other end of the grounding cable. Attach the hook to the grounding post, and secure the hook with a screw.

Figure2-12 Grounding the firewall with the grounding terminal on the rack

 

Installing a power supply

CAUTION:

·     Before installing a power supply, make sure the power supply is powered off and the grounding cable is correctly connected.

·     Do not install AC and DC power supplies on the same firewall.

 

The F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, and F1000-AI-75 firewalls support removable power supplies.

To install a power supply:

1.     Face the rear panel of the firewall.

2.     Remove the filler panel (if any) from the target power supply slot.

The firewall comes with the PWR1 slot empty and the PWR0 slot installed with a filler panel.

Figure2-13 Removing the filler panel

3.     Orient the power supply with its handle at the left. Holding the handle of the module with one hand and supporting the module bottom with the other, slide the power supply slowly into the slot along the guide rails.

4.     Use a Phillips screwdriver to fasten the captive screws on the power supply to secure the power supply in place.

Figure2-14 Installing an AC power supply

 

Figure2-15 Installing a DC power supply

 

Installing an interface module

CAUTION

CAUTION:

·     Do not hot swap interface modules.

·     For smooth interface module installation in the two interface module slots, use slot 2 prior to slot 1 as a best practice. If you are to install an interface module in slot 2 after an interface module has been installed in slot 1, you must press down the ejector levers of the interface module before inserting it into slot 2.

·     No interface modules are provided with the firewall. Purchase them as needed. For interface module compatibility with the firewalls, see "Appendix A Chassis views and technical specifications."

 

The F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, and F1000-AI-75 firewalls support removable interface modules. The installation procedure is the same for all interface modules.

To install an interface module:

1.     Face the rear panel of the firewall.

2.     Use a Phillips screwdriver to remove the screws on the filler panel and then remove the filler panel.

Keep the filler panel for future use.

Figure2-16 Removing the filler panel

 

3.     Pull the ejector levers on the module outward and slide the module slowly into the slot along the guide rails.

4.     Press the ejector levers inward until they touch the panel tightly and the module seats into the slot securely.

5.     Use a Phillips screwdriver to fasten the captive screws on the module.

Figure2-17 Installing an interface module

 

Installing a drive

CAUTION

CAUTION:

·     Do not hot swap drives.

·     To avoid damage to drives, always hold a drive by its sides. Do not touch any components and do not squeeze, vibrate, or strike a drive.

·     Install a filler panel in empty drive slots to prevent dust and ESD damage.

 

IMPORTANT

IMPORTANT:

·     The device does not come with any drives. Purchase drives for the device as needed. For the drives to be identified by the system, purchase the drives from H3C.

·     Before using the drive, execute the fdisk and format commands from the CLI to partition and format the drive.

 

Installing a drive for an F1000-AI-15 firewall

1.     Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.

2.     Remove the filler panel from the drive slot.

3.     Push the drive into the slot slowly along the guide rails.

Figure2-18 Installing a drive for an F1000-AI-15 firewall

 

Installing a drive for other firewalls than the F1000-AI-15

1.     Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.

2.     Remove the filler panel from the drive slot.

3.     Press the button on the drive panel to release the locking lever.

4.     Hold the locking lever and push the drive into the slot slowly along the guide rails.

5.     Close the locking lever.

Figure2-19 Installing a drive

 

Connecting Ethernet cables

Connecting a copper Ethernet port

You can use either a straight-through or a cross-over network cable. For more information about Ethernet twisted pair cables, see "Ethernet twisted pair cable."

To connect a copper Ethernet port:

1.     Connect one end of the Ethernet cable to the copper Ethernet port of the firewall, and the other end to the Ethernet port of the peer device.

2.     Examine whether the LEDs of the Ethernet port are normal. For more information about LEDs, see "Appendix B LEDs."

After connecting the firewall to the network, you can use the ping or tracert command to examine network connectivity. For more information, see the related command reference.

Connecting a fiber port

WARNING

WARNING!

Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare into beams or view directly with optical instruments when the firewall is operating.

 

CAUTION

CAUTION:

·     Never bend or curve a fiber excessively. The bend radius of a fiber must be not less than 100 mm (3.94 in).

·     Keep the fiber end clean.

·     Make sure the fiber connector matches the transceiver module.

·     Before connecting a fiber, make sure the optical power at the receiving end does not exceed the transceiver module's upper threshold of the optical receive power. If the optical power at the receiving end exceeds the threshold, the transceiver module might be damaged.

·     Do not install a transceiver module connected with a fiber into a fiber port. To connect an optical fiber, first install the transceiver module in the fiber port and then connect the fiber.

·     Insert a dust plug into any open fiber port.

·     Make sure the Tx and Rx ports on a transceiver module are connected to the Rx and Tx ports on the peer end, respectively.

 

The firewall supports GE SFP transceiver modules and 10GE SFP+ transceiver modules. For the transceiver module specifications, see "Appendix A Chassis views and technical specifications."

No transceiver module is provided with the firewall. As a best practice, purchase transceiver modules from H3C as needed.

Figure2-20 GE SFP transceiver module

图-1副本

 

Figure2-21 10GE SFP+ transceiver module

 

To connect the firewall to the network through an optical fiber:

1.     Remove the dust plug from the fiber port.

2.     Remove the dust cap from the transceiver module and insert it into the fiber port.

3.     Remove the dust cap of the optical fiber connector, and use dust free paper and absolute alcohol clean the end face of the fiber connector.

4.     Identify the Rx and Tx ports on the transceiver module. Plug one end of the optical fiber into the transceiver module in the firewall, and plug the other end into the transceiver module in the peer device.

Make sure the Rx port and the Tx port are connected to the Tx port and the Rx port on the peer device, respectively.

Figure2-22 Installing and connecting an optical fiber

 

Connecting power cords

CAUTION

CAUTION:

Make sure the grounding cable of the firewall is correctly connected and the power source is powered off before connecting the power cord.

 

Connecting an AC power cord

Connecting an AC power cord for an F1000-AI-05 or F1000-AI-15 firewall

1.     Attach the hooks of the power cord retainer clip into the holes on the top of the AC-input power receptacle, and pull the power cord retainer clip upwards.

2.     Connect one end of the AC power cord to the AC-input power receptacle on the firewall.

3.     Pull the power cord retainer clip downwards and secure the connector to the power receptacle.

4.     Connect the other end of the power cord to an AC power source.

Figure2-23 Connecting an AC power cord for an F1000-AI-05 or F1000-AI-15 firewall

 

Connecting an AC power cord for an F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, or F1000-AI-75 firewall

1.     Attach the hooks of the power cord retainer clip into the holes next to the AC-input power receptacle, and pull the power cord retainer clip leftwards.

2.     Connect the connector of the AC power cord to the target AC power receptacle on the rear panel of the chassis. Then use a power cord retainer clip (see Figure2-24) or a releasable cable tie (see Figure2-25) to secure the power cord.

3.     Connect the other end of the power cord to an AC power source.

Figure2-24 Connecting an AC power cord (using a power cord retainer clip to secure the power cord)

 

Figure2-25 Connecting an AC power cord (using a releasable cable tie to secure the power cord)

 

Connecting a DC power cord

Only the F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65 and F1000-AI-75 firewalls support DC power cords.

To connect a DC power cord for an F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65, or F1000-AI-75 firewall:

1.     Correctly orient the DC power cord connector. Insert the connector into the power receptacle on the power supply.

2.     Fasten the captive screws on the power cord connector with a flat-head screwdriver to secure the power cord connector.

3.     Use a releasable cable tie to secure the power cord to the handle.

4.     Connect the other end of the power cord to a DC power source.

Figure2-26 Connecting and securing a DC power cord

 

Verifying the installation

Verify the following items to ensure correct installation:

·     There is enough space for heat dissipation around the firewall.

·     The firewall and its components are installed securely. The screws are fastened tightly.

·     The power source specifications are as required by the firewall.

·     The grounding cable and power cords are connected correctly.

 


3 Accessing the firewall

Starting the firewall

Pre-start checking

WARNING

WARNING!

Locate the emergency power-off switch in the room before powering on the firewall so you can quickly shut power off when an electrical accident occurs.

 

Before powering on the firewall, verify that the following conditions are met:

·     The power cord and grounding cable are connected correctly.

·     The power source specifications meet the firewall requirements.

·     The firewall is connected correctly to a configuration terminal (a PC for example). The configuration terminal has been started and the parameters have been set correctly. For more information, see "Logging in from the console port."

·     The interface modules (if any) are installed correctly.

Starting the firewall and observing the initial startup conditions

1.     Turn on the circuit breakers to power on the firewall.

2.     Observe the initial startup conditions to verify that the firewall starts up correctly.

¡     The LEDs on the front panel indicate that the device is operating correctly. For more information about LEDs, see "Appendix B LEDs."

¡     The fan blades are rotating and air is exhausted from the air outlet vents.

¡     The configuration terminal displays the following information:

The output on the configuration terminal varies by device software version.

System is starting...

Press Ctrl+D to access BASIC-BOOTWARE MENU...

Press Ctrl+T to start heavy memory test

Booting Normal Extended BootWare

The Extended BootWare is self-decompressing......Done.

****************************************************************************

*                                                                          *

*                   H3C BootWare, Version 1.01                             *

*                                                                          *

****************************************************************************

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd.

 

Compiled Date       : Aug  2 2021

Memory Type         : DDR4 SDRAM

Memory Size           : 8152MB

Memory Speed          : 1037MHz

flash Size            : 3728MB

CPLD 1 Version        : 0.0

CPLD 2 Version        : 1.0

PCB 1 Version         : Ver.A

PCB 2 Version         : Ver.A

 

Press Ctrl+B to access EXTENDED-BOOTWARE MENU...

Loading the main image files...

Loading file flash:/main-CMW710-SYSTEM-A8860P02.bin...Done.

Loading file flash:/main-CMW710-SECESCAN-A8860P02.bin...Done.

Loading file flash:/main-CMW710-BOOT-A8860P02.bin...Done.

 

Image file flash:/main-CMW710-BOOT-A8860P02.bin is self-decompressing....

............................................................................

..................................Done.

System image is starting...

Cryptographic algorithms tests passed.

Line con0 is available.

 

 

Press ENTER to get started...

...

Press Enter to access user view of the firewall.

 

 

NOTE:

To access the EXTENDED-BOOTWARE menu, press Ctrl + B within four seconds at the prompt "Press Ctrl+B to access EXTENDED-BOOTWARE MENU." If you do not press Ctrl+B at the prompt, the system starts to read and decompress program files. To enter the EXTENDED-BOOT menu afterwards, you need to reboot the device.

 

Logging in to the firewall

IMPORTANT

IMPORTANT:

After accessing the device with the default account, immediately modify the password of the default account, or create a new administrator account and delete the default account as a best practice.

 

You can use the following methods to access and manage the firewall. For more information about logging in to the firewall, see the configuration guides and command references for the firewall.

·     Logging in from the Web interface

·     Logging in from the console port

·     Logging in through Telnet

Logging in from the Web interface

At the first login from the Web interface, you can use the default account or use an account created from the CLI. Table3-1 shows the default Web interface login information.

Table3-1 Default Web interface login information

Item

Default configurations

Username

admin

Password

admin

Management Ethernet port

·     F1000-AI-05/F1000-AI-25/F1000-AI-35/F1000-AI-55/F1000-AI-65/F1000-AI-75: 0/MGMT

·     F1000-AI-15:

¡     0/MGMT

¡     1/MGMT

IP address of the management Ethernet port

·     0/MGMT192.168.0.1/24

·     1/MGMT—192.168.1.1/24

 

To log in to the firewall from the Web interface by using the default account:

1.     Use an Ethernet cable to connect a PC to the management Ethernet port on the firewall.

2.     Configure an IP address in subnet 192.168.0.0/24 for the PC. Make sure the PC and the firewall are reachable to each other.

The PC must use a different IP address than the management Ethernet port.

3.     Start a browser, enter 192.168.0.1 in the address bar, and press Enter.

4.     Enter the default username admin and password admin and then click Login.

5.     Modify the login information.

At the first login from the Web interface, change the password as required in the pop-up window, and then click OK.

Keep the new password secure.

Logging in from the console port

By default, the firewall uses the scheme access authentication mode. The username and password are both admin.

To configure and manage the firewall from the console port, you must run a terminal emulator program, TeraTermPro or PuTTY, on your configuration terminal and configure the following settings for the terminal. For more information about the terminal emulator programs, see the user guides for these programs.

·     Bits per second—9600.

·     Data bits—8.

·     Stop bits—1.

·     Parity—None.

·     Flow control—None.

Logging in through Telnet

1.     Log in to the firewall through the console port, and enable the Telnet function in system view by using the telnet server enable command.

2.     Enter VTY user line view, and configure the authentication mode, user role, and common properties in VTY user line view.

By default, the authentication mode is scheme, and the username and password are admin.

3.     Connect a PC to the management Ethernet port M-GigabitEthernet1/0/0 on the firewall.

4.     Specify an IP address for the network port of the PC. The IP address must be in subnet 192.168.0.0/24 and cannot be 192.168.0.1.

5.     Run the Telnet client on the PC and enter the default login information. 


4 Hardware replacement

CAUTION

CAUTION:

Wear an ESD wrist strap or ESD gloves for hardware maintenance. They are not provided with the firewall. Prepare them yourself.

 

Replacing a power supply

CAUTION

CAUTION:

Before you replace a power supply, turn off the circuit breaker and then remove the power cord.

 

This section applies only to F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65 and F1000-AI-75 firewalls that support removable power supplies. The replacement procedure is the same for an AC power supply and a DC power supply. This section takes a DC power supply as an example.

To replace a power supply:

1.     Face the rear panel of the firewall.

2.     Use a Phillips screwdriver to loosen the captive screws of the power supply.

3.     Hold the power supply with one hand and pull the power supply part way out of the slot.

4.     Supporting the bottom of the power supply with the other hand, gently pull the power supply out of the slot along the slide rails.

Figure4-1 Removing a power supply

 

5.     Put the removed power supply on a workbench or into an antistatic bag.

6.     Install a new power supply. If you do not install a new power supply in the slot, install a filler panel. For the installation procedure, see "Installing a power supply."

Replacing an interface module

CAUTION

CAUTION:

·     Do not hot swap interface modules. Power off the firewall before you replace an interface module.

·     For smooth interface module installation in the two interface module slots, use slot 2 prior to slot 1 as a best practice. If you are to install an interface module in slot 2 after an interface module has been installed in slot 1, you must press down the ejector levers of the interface module before inserting it into slot 2.

 

The F1000-AI-05 and F1000-AI-15 do not support interface modules.

To replace an interface module:

1.     Power off the firewall.

2.     Use a Phillips screwdriver to loosen the captive screws of the interface module.

3.     Holding the ejector levers of the interface module with both hands, pull the ejector levers outward, and pull the interface module part way out of the slot along the slide rails. Supporting the bottom of the interface module with one hand, gently pull the interface module out of the slot with the other.

4.     Put the removed interface module (with the circuit board facing upward) on an antistatic workbench or into an antistatic bag.

5.     Install a new interface module. For the installation procedure, see "Installing an interface module."

If you are not to install a new interface module, install a filler panel in the slot to ensure good ventilation in the firewall.

Figure4-2 Removing an interface module

 

Replacing a drive

CAUTION

CAUTION:

·     To avoid storage medium damage, execute the umount command from the CLI to unmount all the file systems before removing a drive.

·     Do not hot swap drives.

 

Replacing a drive for an F1000-AI-15 firewall

1.     Log in to the Web interface. Click the Unmount button on the Storage settings page.

2.     Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.

3.     Pull the drive slowly out of the slot along the guide rails.

4.     Install a new drive. For the installation procedure, see "Installing a drive for an F1000-AI-15 firewall."

If you are not to install a new drive in the slot, install a filler panel in the slot to prevent dust and ensure good ventilation.

Figure4-3 Replacing a drive for an F1000-AI-15 firewall

 

Replacing a drive for the F1000-AI-05, F1000-AI-25, F1000-AI-35, F1000-AI-55, F1000-AI-65 and F1000-AI-75 firewalls

1.     Log in to the Web interface. Click the Unmount button on the Storage settings page.

2.     Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.

3.     Press the button on the drive panel to release the locking lever.

4.     Hold the locking lever and pull the drive out of the slot.

5.     Install a new drive. For the installation procedure, see "Installing a drive for other firewalls than the F1000-AI-15."

If you are not to install a new drive in the slot, install a filler panel in the slot to prevent dust and ensure good ventilation.

Figure4-4 Removing a drive

 

Replacing a transceiver module

WARNING

WARNING!

Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare into beams or view directly with optical instruments when the firewall is operating.

 

When you replace a transceiver module, make sure the two transceiver modules connected by the same optical fiber are the same type. Do not touch the golden plating of the transceiver module.

Figure4-5 Transceiver module golden plating

 

To replace a transceiver module:

1.     Use the shutdown command in interface view at the CLI to shut down the optical source before you remove the fiber connector.

2.     Remove the LC connectors with the optical fiber from the transceiver module, and install dust caps to the LC connectors.

3.     Pivot the clasp of the transceiver module down to the horizontal position, and gently pull the transceiver module out.

Figure4-6 Removing the transceiver module

 

4.     Install dust caps to the removed transceiver module, and put it into the package.

5.     Install a new transceiver module. If you do not install a new transceiver module in the slot, install a dust cap. For information about installing a transceiver module, see "Connecting a fiber port."  


5 Hardware management and maintenance

 

NOTE:

The output depends on your firewall model. For more information about the commands used in this chapter, see the configuration guides and command references for the firewall.

 

Displaying detailed information about the firewall

Use the display device verbose command to display detailed information, including the running status and hardware version, about the firewall and its interface modules.

<Sysname> display device verbose

 

Slot 1 SubSlot 0 info:

Status           :   Normal

Type             :   F1000-AI-65

PCB 1 Ver        :   VER.A

Software Ver     :   8860P02

CPU Ver          :   1.0

CPLD_A           :   128.0

CPLD_B           :   129.0

CFCard Num       :   0

Displaying the software and hardware version information for the firewall

Use the display version command to display software and hardware version information for the firewall.

<Sysname> display version

H3C Comware Software, Version 7.1.064, Alpha 8860P02

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd. All rights reserved.

H3C SecPath F1000-AI-65 uptime is 0 weeks, 0 days, 5 hours, 21 minutes

Last reboot reason: User reboot

Boot image: flash:/main-CMW710-BOOT-A8860P02.bin

Boot image version: 7.1.064, Alpha 8860P02

  Compiled Jul 14 2021 15:00:00

System image: flash:/main-CMW710-SYSTEM-A8860P02.bin

System image version: 7.1.064, Alpha 8860P02

  Compiled Jul 14 2021 15:00:00

Feature image(s) list:

  flash:/main-CMW710-SECESCAN-A8860P02.bin, version: 7.1.064

    Compiled Jul 14 2021 15:00:00

SLOT 1

CPU type:           Multi-core CPU

DDR4 SDRAM Memory:   8192M bytes

FLASH:              3728M bytes

CPLD_A           Version:128.0

CPLD_B           Version:129.0

Release          Version:SecPath F1000-AI-65-8860P02

Basic  BootWare  Version:1.01

Extend BootWare  Version:1.01

BuckleBoard Version:Ver.A

BaseBoard Version:Ver.A

BackBoard Version:Ver.A

HDD BackBoard Version:Ver.A

[SUBCARD 0] NSQ1F1G2MSPUOTXA(Hardware)Ver.A, (Driver)1.0, (Cpld)128.0

Boot Type: Cold

Displaying the electrical label information for the firewall

Use the display device manuinfo command to display the electrical label information for the firewall.

<Sysname> display device manuinfo

Slot 1 CPU 0:

 DEVICE_NAME          : F1000-AI-65

 DEVICE_SERIAL_NUMBER : 210235A2H79196Q0000B

 MAC_ADDRESS          : 0868-8DBC-3B73

 MANUFACTURING_DATE   : NONE

 VENDOR_NAME          : NONE

Fan 0:

The operation is not supported on the specified fan.

Fan 1:

The operation is not supported on the specified fan.

Fan 2:

The operation is not supported on the specified fan.

Fan 3:

The operation is not supported on the specified fan.

Power 0:

 DEVICE_NAME          : PSR150-A1

 DEVICE_SERIAL_NUMBER : 210231A1U0H16B005100

 MAC_ADDRESS          : NONE

 MANUFACTURING_DATE   : NONE

 VENDOR_NAME          : H3C

Table5-1 Output description

Field

Description

DEVICE_NAME

Firewall name.

DEVICE_SERIAL_NUMBER

Firewall serial number.

MAC_ADDRESS

MAC address of the firewall.

MANUFACTURING_DATE

Manufacturing date of the firewall.

VENDOR_NAME

Vendor name.

 

Displaying the CPU usage of the firewall

Use the display cpu-usage command to display the CPU usage of the firewall.

<Sysname> display cpu-usage

Slot 1 CPU 0 CPU usage:

       3% in last 5 seconds

       3% in last 1 minute

       3% in last 5 minutes

Table5-2 Output description

Field

Description

Slot 1 CPU 0 CPU usage

CPU 0 usage information for the interface module in slot 1.

3% in last 5 seconds

Average CPU usage in the last 5 seconds. (After the firewall boots, the firewall calculates and records the average CPU usage at the interval of 5 seconds.)

3% in last 1 minute

Average CPU usage in the last minute. (After the firewall boots, the firewall calculates and records the average CPU usage at the interval of 1 minute.)

3% in last 5 minutes

Average CPU usage in the last 5 minutes. (After the firewall boots, the firewall calculates and records the average CPU usage at the interval of 5 minutes.)

 

Displaying the memory usage of the firewall

Use the display memory command to display the memory information of the firewall.

<Sysname> display memory

Memory statistics are measured in KB:

Slot 1:

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       8212672   4655360   3557312         0     17152    549952       43.9%

-/+ Buffers/Cache:   4088256   4124416

Swap:           0         0         0

 

Table5-3 Output description

Field

Description

Slot

Slot number of the interface module

Mem

Memory usage information.

Total

Total size of the physical memory space that can be allocated.

The memory space is virtually divided into two parts. Part 1 is used for kernel codes, kernel management, and ISSU functions. Part 2 can be allocated and used for such tasks as running service modules and storing files. The size of part 2 equals the total size minus the size of part 1.

Used

Used physical memory.

Free

Free physical memory.

Shared

Physical memory shared by processes.

Buffers

Physical memory used for buffers.

Cached

Physical memory used for caches.

FreeRatio

Free memory ratio.

-/+ Buffers/Cache

-/+ Buffers/Cache:used = Mem:Used – Mem:Buffers – Mem:Cached, which indicates the physical memory used by applications.

-/+ Buffers/Cache:free = Mem:Free + Mem:Buffers + Mem:Cached, which indicates the physical memory available for applications.

Swap

Swap memory.

 

Displaying the temperature information of the firewall

Use the display environment command to display the temperature information of the firewall.

<Sysname> display environment

System Temperature information (degree centigrade):

--------------------------------------------------------------------------------

---------

 Slot     Sensor   Temperature LowerLimit Warning-UpperLimit  Alarm-UpperLimit Shutdown-UpperLimit

1      inflow  1      31          0              47                52

     60

1      outflow 1      39          0              68                80

     88

1      hotspot 1      47          0              63                68

     75

1      hotspot 2      54          0              84                97

     102

Table5-4 Output description

Field

Description

Sensor

Temperature sensor:

·     inflow—Air inlet vent temperature sensor.

·     outflow—Air outlet vent temperature sensor.

·     hotspot—Hotspot temperature sensor.

Temperature

Current temperature.

LowerLimit

Low temperature alarm threshold.

Warning-UpperLimit

Warning-level high temperature alarm threshold.

Alarm-UpperLimit

Alarm-level high temperature alarm threshold.

Shutdown-Upperlimit

Shutdown-level high temperature alarm threshold. The firewall automatically powers off when the temperature exceeds this threshold.

 

Displaying the operational statistics of the firewall

When you perform routine maintenance or the system fails, you might need to view the operational information of each functional module for locating failures. Typically you need to run display commands one by one. To collect more information one time, you can execute the display diagnostic-information command in any view to display or save the operational statistics of multiple functional modules of the firewall.

·     Save the operational statistics of each functional module of the firewall:

<Sysname> display diagnostic-information

Save or display diagnostic information (Y=save, N=display)? [Y/N]:y

Please input the file name(*.tar.gz)[sda0:/diag_H3C_20210807-155002.tar.gz]:

Diagnostic information is outputting to sda0:/diag_H3C_20210807-155002.tar.gz.

Please wait...

Save successfully.

To view the diag.gz file:

a.     In user view, execute the tar extract archive-file diag.tar.gz command and then the gunzip diag.gz command to decompress the file.

b.     Execute the more diag command.

c.     Press Pg Up and Pg Down.

·     Display the operational statistics for each functional module of the firewall:

<Sysname> display diagnostic-information

<Sysname>display diagnostic-information

Save or display diagnostic information (Y=save, N=display)? [Y/N]:n

===============================================

  ===============display clock===============

15:54:53 UTC Fri 08/07/2021

=================================================

  ===============display version===============

H3C Comware Software, Version 7.1.064, Alpha 8860P02

Copyright (c) 2004-2021 New H3C Technologies Co., Ltd. All rights reserved.

H3C SecPath F1000-AI-65 uptime is 1 week, 2 days, 2 hours, 9 minutes

...

Displaying transceiver module information

Identifying transceiver modules

To identify transceiver modules, you can use the following command to view the key parameters of the transceiver modules, including transceiver module type, connector type, central wavelength of the laser sent, transmission distance, and vendor name or name of the vendor who customizes the transceiver modules.

To display transceiver module information:

 

Task

Command

Remarks

Display key parameters of the transceiver module in a specific interface.

display transceiver interface [ interface-type interface-number ]

Available for all transceiver modules.

 

Troubleshooting transceiver modules

The system outputs alarm information for you to locate and troubleshoot faults of transceiver modules.

To display the alarming information or fault detection parameters of a transceiver module:

 

Task

Command

Remarks

Display the current alarm information of the transceiver module in a specific interface.

display transceiver alarm interface [ interface-type interface-number ]

Available for all transceiver modules.

 

Rebooting the firewall

CAUTION

CAUTION:

·     If the main system software image file does not exist, do not use the reboot command to reboot the firewall. Specify the main system software image file first, and then reboot the firewall.

·     The precision of the rebooting timer is 1 minute. 1 minute before the rebooting time, the firewall prompts "REBOOT IN ONE MINUTE" and reboots in one minute.

·     If you are performing file operations when the firewall is to be rebooted, the system does not execute the reboot command for security.

 

To reboot a firewall, use one of the following methods:

·     Use the reboot command to reboot the firewall immediately.

·     Enable the scheduled reboot function at the CLI. You can set a time at which the firewall can automatically reboot, or set a delay so that the firewall can automatically reboot within the delay.

·     Power on the firewall after powering it off, which is also called hard reboot or cold start. H3C does not recommend that you use this method because it might cause data loss and hardware damages.

To reboot the firewall immediately:

 

Task

Command

Remarks

Reboot the firewall immediately.

reboot

Available in user view.

 

To enable the scheduled reboot function:

 

Task

Command

Remarks

Enable the scheduled reboot function.

·     Enable the scheduled reboot function and specify a specific reboot time and date:
scheduler reboot at

·     Enable the scheduled reboot function and specify a reboot waiting time:
scheduler reboot delay

Use either approach.

The scheduled reboot function is disabled by default.

Available in user view.

 

 


6 Troubleshooting

Power supply failure

Symptom

The firewall cannot be powered on, and the power LED (PWR0/PWR1) on the front panel is off.

Solution

To solve the issue:

1.     Power off the firewall.

2.     Verify that the power supply is as required by the firewall.

3.     Verify that the power cords of the firewall are firmly connected.

4.     Verify that the power cords are not damaged.

5.     If the issue persists, contact your local sales agent.

Configuration terminal display issue

Symptom

The configuration terminal displays nothing or garbled text when the firewall is powered on.

Solution

To solve the issue:

1.     Verify that the power supply system is operating correctly.

2.     Verify that the console cable is correctly connected.

3.     Verify that the console cable is connected to the serial port configured on the configuration terminal.

4.     Verify that the configuration terminal parameters are configured as follows:

¡     Baud rate—9600.

¡     Data bits—8.

¡     Parity—None.

¡     Stop bits—1.

¡     Flow control—None.

¡     Terminal emulation—VT100.

5.     Verify that the console cable is in good condition.

6.     If the issue persists, contact your local sales agent.

Password loss

To deal with loss of the password used for accessing the firewall through the console port, see the release notes for the firewall.

Cooling system failure

Symptom

The temperature of the firewall is higher than the normal operating temperature (45°C or 113°F).

Solution

To solve the issue:

1.     Verify that the fans are operating correctly.

2.     Verify that the operating environment of the firewall has good ventilation.

3.     If the following alarm information is generated, the temperature of the firewall has reached the warning-level high temperature alarm threshold.

%Aug 28 20:02:59:085 2021 H3C DEV/4/TEMPERATURE_WARNING: -Context=1; Temperature is greater than the high-temperature warning threshold on slot 1 sensor outflow 1. Current temperature is 58 degrees centigrade.

Use the display environment command to examine whether the temperature of the firewall keeps rising. If the temperature has reached the alarming-level high temperature alarm threshold, power off the firewall, and contact your local sales agent. If the temperature has reached the shutdown-level high temperature alarm threshold, the device will shut down automatically.

Information about the firewall temperature in the display environment command output varies by firewall model.

4.     If the issue persists, contact your local sales agent.

Software loading failure

Symptom

Software loading fails and the system runs the software of the previous version.

Solution

To solve the issue:

1.     Verify that the physical ports are correctly connected.

2.     Verify that no parameter is configured incorrectly during the loading process. You can examine the software loading process displayed on the HyperTerminal for configuration errors. The following errors can lead to software loading failure.

¡     When XMODEM is used to load software, a baud rate other than 9600 bps is selected, but the baud rate for the HyperTerminal is not reset.

¡     When TFTP is used to load software, an incorrect IP address, software name, or TFTP serve path is configured.

¡     When FTP is used to load software, an incorrect IP address, software name, username, or password is entered.

3.     If the issue persists, contact your local sales agent.

7 Appendix A  Chassis views and technical specifications

Chassis views

F1000-AI-05

The F1000-AI-05 firewall provides the following ports on the front panel:

·     Eight 10/100/1000BASE-T autosensing Ethernet copper ports.

·     Two combo interfaces.

·     Two bypass ports.

·     One USB port.

·     One console port.

·     One drive slot.

Figure7-1 Front panel

(1) Drive slot

(2) Console port

(3) USB port (host mode, type A)

(4) 10/100/1000BASE-T copper port (combo interface)

(5) Bypass ports

(6) 10/100/1000BASE-T copper ports

(7) LEDs

(8) 1000BASE-X fiber ports (combo interfaces)

(9) Management Ethernet port (0/MGMT, combo interface)

 

Figure7-2 Rear panel

(1) Grounding screw

(2) Power receptacle

 

F1000-AI-15

The F1000-AI-15 firewall provides the following ports on the front panel:

·     Eighteen 10/100/1000BASE-T autosensing Ethernet copper ports.

·     Two 10GBASE-R fiber ports.

·     Two management Ethernet ports.

·     Four bypass ports.

·     Eight combo interfaces.

·     One console port.

·     Two USB ports.

·     One reset button.

·     Two drive slots.

Figure7-3 Front panel

(1) Drive slot

(2) Management Ethernet port (1/MGMT)

(3) Bypass ports

(4) 10/100/1000BASE-T copper ports (combo interfaces)

(5) 1000BASE-X fiber ports (combo interfaces)

(6) LEDs

(7) Console port

(8) USB port (host mode, type A)

(9) Reset button

(10) 10GBASE-R fiber port

(11) 10/100/1000BASE-T copper ports

(12) Management Ethernet port (0/MGMT)

 

Figure7-4 Rear panel

(1) Power receptacle 1

(2) Power receptacle 2

(3) Grounding screw

 

F1000-AI-25/F1000-AI-35/F1000-AI-55

The F1000-AI-25/F1000-AI-35/F1000-AI-55 firewall provides the following ports on the front panel:

·     Sixteen 10/100/1000BASE-T autosensing Ethernet copper ports.

·     Four combo interfaces.

·     Six 1000BASE-X fiber ports.

·     Two 10GBASE-R fiber ports.

·     Two USB ports.

·     One console port.

·     One drive slot.

·     One management Ethernet port.

Figure7-5 Front panel

(1) Drive slot

(2) LEDs

(3) Console port

(4) 10/100/1000BASE-T copper ports

(5) 10/100/1000BASE-T copper ports (combo interfaces)

(6) 1000BASE-X fiber ports (combo interfaces)

(7) 1000BASE-X fiber ports

(8) 10GBASE-R fiber port

(9) Management Ethernet port (MGMT)

(10) USB port (host mode, Type A)

(11) Reset button

 

Figure7-6 Rear panel

(1) Power supply slots

(2) Interface module slots

(3) Grounding screw

 

F1000-AI-65/F1000-AI-75

The F1000-AI-65/F1000-AI-75 firewall provides the following ports on the front panel:

·     Sixteen 10/100/1000BASE-T autosensing Ethernet copper ports.

·     Four combo interfaces.

·     Four 1000BASE-X fiber ports.

·     Six 10GBASE-R fiber ports.

·     Two USB ports.

·     One console port.

·     Two drive slots.

·     One management Ethernet port.

Figure7-7 Front panel

(1) Drive slot

(2) LEDs

(3) Console port

(4) 10/100/1000BASE-T copper ports

(5) 10/100/1000BASE-T copper ports (combo interfaces)

(6) 1000BASE-X fiber ports (combo interfaces)

(7) 1000BASE-X fiber ports

(8) 10GBASE-R fiber ports

(9) Management Ethernet port (MGMT)

(10) USB port (host mode, Type A)

(11) Reset button

 

Figure7-8 Rear panel

(1) Power supply slots

(2) Interface module slots

(3) Grounding screw

 

Interface modules

CAUTION

CAUTION:

Do not hot swap interface modules.

 

Table7-1 displays the compatible slots for the interface modules.

Table7-1 Interface module and device slot compatibility

Firewall model

Slot number

Slot speed

Compatible interface module

F1000-AI-05/F1000-AI-15

N/A

Not supported

Not supported

F1000-AI-25/F1000-AI-35/F1000-AI-55

Slots 1 and 2

Low speed

·     NSQM1GT4PFC

·     NSQM1GP4FBA

F1000-AI-65/F1000-AI-75

Slot 1

High speed

NS-NIM-TG6A

Slot 2

Low speed

·     NSQM1GT4PFC

·     NSQM1GP4FBA

 

NSQM1GT4PFC

The NSQM1GT4PFC interface module provides four 10/100/1000BASE-T Ethernet copper ports.

·     When the firewall is operating correctly, the four ports operate as common data ports.

·     When the firewall is powered off, the four ports are divided into two bypass port pairs with ports 0 and 1 in one pair and ports 2 and 3 in another pair. The two ports in a pair can act as the uplink and downlink interfaces for a Layer 2 link and form a bypass link. This enables traffic to be transmitted through the firewall even if the firewall is powered off and ensures service continuity.

Figure7-9 Front panel of the NSQM1GT4PFC interface module

(1) 10/100/1000BASE-T copper ports

(2) Captive screw

(3) Ejector lever

 

NSQM1GP4FBA

The NSQM1GP4FBA interface module provides four 1000BASE-X fiber ports.

Figure7-10 Front panel of the NSQM1GP4FBA interface module

(1) 1000BASE-X fiber ports

(2) Captive screw

(3) Ejector lever

 

NS-NIM-TG6A

The NS-NIM-TG6A interface module provides six 10GBASE-R fiber ports.

Figure7-11 Front panel of the NS-NIM-TG6A interface module

(1) 10GBASE-R fiber ports

(2) Captive screw

(3) Ejector lever

 

Drives

CAUTION

CAUTION:

Do not hot swap drives.

 

Table7-2 displays drive compatibility with the firewalls.

Table7-2 Drive compatibility with the firewalls

Drive model

F1000-AI-15

F1000-AI-05/F1000-AI-25/F1000-AI-35/F1000-AI-55/F1000-AI-65/F1000-AI-75

NS-SSD-480G-SATA-M.2

Supported

Not supported

NS-SSD-480G-SATA-SFF

Not supported

Supported

NS-HDD-500G-SATA-SFF

Not supported

Supported

NS-HDD-1T-SATA-SFF

Not supported

Supported

 

Network data encryption modules

CAUTION

CAUTION:

Do not hot swap network data encryption modules.

 

The appearance of network data encryption modules varies by models. For more information, see H3C SecPath Firewall Network Data Encryption Module Guide.

Table7-3 describes the network data encryption module compatibility with the firewalls and software.

Table7-3 Network data encryption module compatibility with the firewalls and software

Network data encryption module

Applicable firewalls

Applicable slots

Applicable software version

NSQM1F1KGMC

F1000-AI-25

F1000-AI-35

F1000-AI-55

F1000-AI-65

F1000-AI-75

Slots 1 and 2

R8860P1210 and later

 

Power supplies

The firewall provides two power supply slots PWR0 and PWR1 and supports both AC and DC removable power supplies. No power supplies are provided with the firewall. Prepare power supplies for the firewall yourself as required.

The firewall supports 1+1 power supply redundancy. To install two power supplies for the firewall, make sure they are the same model.

AC power supplies

The device supports the PSR150-A1 AC power supply with a product code of PSR150-A1-B that provides a maximum output power of 150 W.

Figure7-12 PSR150-A1 AC power supply

(1) Handle

(2) AC-input power receptacle

 

DC power supplies

The device supports the PSR150-D1 DC power supply with a product code of PSR150-D1-B that provides a maximum output power of 150 W.

Figure7-13 PSR150-D1 DC power supply

(1) Handle

(2) DC-input power receptacle

 

Dimensions and weights

The weight of the firewall includes the chassis and its removable components.

Chassis

Table7-4 Chassis dimensions and weights

Firewall model

Dimensions (H × W × D), excluding rubber feet and mounting brackets

Net weight (chassis only)

F1000-AI-05

44 × 440 × 230 mm (1.73 × 17.32 × 9.06 in)

3 kg (6.61 lb)

F1000-AI-15

43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in)

3.7 kg (8.16 lb)

F1000-AI-25/F1000-AI-35/F1000-AI-55

44.2 × 440 × 435 mm (1.74 × 17.32 × 17.13 in)

5.4 kg (11.90 lb)

F1000-AI-65/F1000-AI-75

44.2 × 440 × 435 mm (1.74 × 17.32 × 17.13 in)

5.6 kg (12.35 lb)

 

Interface modules

Table7-5 Interface module dimensions and weights

Interface module model

Dimensions (H × W × D)

Weight

NSQM1GT4PFC

19 × 150 × 172.9 mm (0.75 × 5.91 × 6.81 in)

0.45 kg (0.99 lb)

NSQM1GP4FBA

19 × 150 × 172.9 mm (0.75 × 5.91 × 6.81 in)

0.42 kg (0.93 lb)

NS-NIM-TG6A

19 × 150 × 172.9 mm (0.75 × 5.91 × 6.81 in)

0.40 kg (0.88 lb)

 

Network data encryption modules

Table7-6 Network data encryption module dimensions and weight

Network data encryption module model

Dimensions (H × W × D)

Weight

NSQM1F1KGMC

19.8 × 150 × 172.9 mm (0.78 × 5.91 × 6.81 in)

0.38 kg (0.84 lb)

 

Drives

Table7-7 Drive dimensions and weights

Drive model

Dimensions (H × W × D)

Weight

NS-SSD-480G-SATA-M.2

12.1 × 27.1 × 99.4 mm (0.48 × 1.07 × 3.91 in)

0.05 kg (0.11 lb)

NS-SSD-480G-SATA-SFF

19 × 75.7 × 118.4 mm (0.75 × 2.98 × 4.66 in)

0.07 kg (0.15 lb)

NS-HDD-500G-SATA-SFF

19 × 75.7 × 118.4 mm (0.75 × 2.98 × 4.66 in)

0.12 kg (0.26 lb)

NS-HDD-1T-SATA-SFF

19 × 75.7 × 118.4 mm (0.75 × 2.98 × 4.66 in)

0.14 kg (0.31 lb)

 

Storage media

Table7-8 Storage media specifications

Firewall model

Memory

F1000-AI-05/F1000-AI-15/F1000-AI-25/F1000-AI-35

4GB DDR4

F1000-AI-55/F1000-AI-65/F1000-AI-75

8GB DDR4

 

Table7-9 Memory specifications of drives

Drive model

Memory

NS-SSD-480G-SATA-M.2

480 GB

NS-SSD-480G-SATA-SFF

480 GB

NS-HDD-500G-SATA-SFF

500 GB

NS-HDD-1T-SATA-SFF

1 TB

 

Power consumption

The system power consumption includes the power consumptions of the chassis and the removable components.

Chassis

Table7-10 Chassis power consumption

Firewall model

Minimum power consumption

Maximum power consumption

F1000-AI-05

18 W

32 W

F1000-AI-15

18 W

48 W

F1000-AI-25/F1000-AI-35/F1000-AI-55

23 W

46 W

F1000-AI-65/F1000-AI-75

46 W

90 W

 

Interface modules

Table7-11 Interface module power consumption

Interface module model

Power consumption

NSQM1GT4PFC

11.5 W

NSQM1GP4FBA

10.4 W

NS-NIM-TG6A

11 W

 

Network data encryption modules

Table7-12 Network data encryption module power consumption

Network data encryption module model

Power consumption

NSQM1F1KGMC

5.7 W

 

Drives

Table7-13 Drive power consumption

Drive model

Power consumption

NS-SSD-480G-SATA-M.2

4.5 W

NS-SSD-480G-SATA-SFF

3 W

NS-HDD-500G-SATA-SFF

4.9 W

NS-HDD-1T-SATA-SFF

5 W

 

Power supply specifications

Table7-14 AC power supply specifications

Item

Specifications

Model

PSR150-A1

Rated input voltage range

100 VAC to 240 VAC @ 50 Hz or 60 Hz

Maximum input current

2 A

Maximum power

150 W

 

Table7-15 DC power supply specifications

Item

Specifications

Model

PSR150-D1

Rated input voltage range

–48 VDC to –60 VDC

Maximum input current

6 A

Maximum power

150 W

 

Port specifications

Console port

Table7-16 Console port specifications

Item

Specification

Connector

RJ-45

Standard compliant

RS-232

Baud rate

9600 bps (default) to 115200 bps

Cable type

Common asynchronous serial port cable

Transmission distance

≤ 15 m (49.21 ft)

Services

·     Connection to an ASCII terminal

·     Connection to the serial port of a local PC running the terminal emulation program

·     CLI

 

GE copper port

Table7-17 GE copper port specifications

Item

Specification

Connector

RJ-45

Standard compliance

802.3, 802.3u, and 802.3ab

Interface type

MDI/MDI-X autosensing

Cable type

Category 5 or higher twisted pair cable

Transmission distance

100 m (328.08 ft)

Interface speed and duplex mode

10 Mbps, half/full-duplex

100 Mbps, half/full-duplex

1000 Mbps, full-duplex

 

 

NOTE:

The interfaces on a network interface card are typically media dependent interface (MDI) interfaces. The interfaces on a hub or LAN switch are typically media dependent interface crossover (MDI-X) interfaces.

 

GE fiber port

Table7-18 GE fiber port specifications

Item

Specification

Connector type

LC

Transceiver module type

SFP

Standard compliance

1000BASE-X

Interface speed

1000 Mbps

Duplex mode

Full duplex

 

Table7-19 1000BASE-X SFP transceiver module specifications

Transceiver module

Central wavelength (nm)

Connector type

Cable specifications (µm)

Max transmission distance

SFP-GE-SX-MM850-A

850

LC

50/125, multi-mode optical fiber (MMF)

0.55 km (1804.46 ft)

SFP-GE-LX-SM1310-A

1310

LC

9/125, single-mode optical fiber (SMF)

10 km (6.21 miles)

SFP-GE-LH40-SM1310

1310

LC

9/125, SMF

40 km (24.86 miles)

SFP-GE-LH40-SM1550

1550

LC

9/125, SMF

40 km (24.86 miles)

SFP-GE-LH80-SM1550

1550

LC

9/125, SMF

80 km (49.71 miles)

SFP-GE-LH100-SM1550

1550

LC

9/125, SMF

100 km (62.14 miles)

 

10 GE fiber port

Table7-20 10 GE fiber port specifications

Item

Specification

Connector type

LC

Transceiver module type

SFP+

Standard compliance

10GBASE-R

Interface speed

LAN PHY: 10.3125 Gbps

 

Table7-21 10 Gbps SFP+ transceiver module specifications

Transceiver module

Central wavelength (nm)

Connector type

Cable specifications (µm)

Max transmission distance

SFP-XG-SX-MM850-A

850

LC

50/125, MMF

300 m (984.25 ft)

82 m (269.03 ft)

66 m (216.54 ft)

62.5/125, MMF

33 m (108.27 ft)

26 m (85.30 ft)

SFP-XG-LX220-MM1310

1310

LC

62.5/125, MMF

220 m (721.78 ft)

50/125, MMF

220 m (721.78 ft)

100 m (328.08 ft)

SFP-XG-LX-SM1310

1310

LC

9/125, SMF

10 km (6.21 miles)

SFP-XG-LH40-SM1550

1550

LC

9/125, SMF

40 km (24.86 miles)

 

8 Appendix B  LEDs

F1000-AI-05

Table8-1 LED description

LED

Mark

Status

Description

4G module LED

LTE

Off

The 4G module is faulty or in airplane mode.

Flashing green (1 Hz)

The 4G module is searching for a network.

Flashing green (0.3 Hz)

The 4G module has connected to a network and the system is operating correctly.

Flashing green (2.5 Hz)

The 4G module is transmitting data.

Drive status LED

HDD

Fast flashing green

Data is being read from or written to the drive.

Steady green

The drive is present and operating correctly.

10/100/1000BASE-T copper port LED

10/100/1000BASE-T

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is receiving and sending data at 10 Mbps or 100 Mbps.

10/100/1000BASE-T copper port LED (combo interfaces)

10/100/1000BASE-T

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is receiving and sending data at 10 Mbps or 100 Mbps.

1000BASE-X fiber port LED (combo interfaces)

1000BASE-X

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

System status LED

SYS

Off

The firewall is not powered on or has failed.

Flashing green at 0.5 Hz

The firewall is operating correctly.

Flashing green at 4 Hz

The firewall is loading software.

Power supply status LED

PWR

Off

No power supply is present or the power supply has failed.

Steady green

The power supply is operating correctly.

 

F1000-AI-15

Table8-2 LED description

LED

Mark

Status

Description

10/100/1000BASE-T copper port LED

10/100/1000BASE-T

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is receiving and sending data at 10 Mbps or 100 Mbps.

10/100/1000BASE-T copper port LED (combo interfaces)

10/100/1000BASE-T

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is receiving and sending data at 10 Mbps or 100 Mbps.

1000BASE-X fiber port LED (combo interfaces)

1000BASE-X

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

10GE fiber port LED

10GBASE-R

Off

No link is present.

Steady green

A 10 Gbps link is present.

Flashing green

The port is receiving and sending data at 10 Gbps.

System status LED

SYS

Off

The firewall is not powered on or has failed.

Flashing green at 0.5 Hz

The firewall is operating correctly.

Flashing green at 4 Hz

The firewall is loading software.

Power supply status LED

PWR

Off

No power supply is present or the power supply has failed.

Steady green

The power supply is operating correctly.

 

F1000-AI-25/F1000-AI-35/F1000-AI-55/F1000-AI-65/F1000-AI-75

Table8-3 LED description

LED

Mark

Status

Description

System status LED

SYS

Off

The firewall is not powered on or has failed.

Flashing green at 0.5 Hz

The firewall is operating correctly.

Flashing green at 4 Hz

The firewall is loading software.

Power supply status LED

PWR0, PWR1

Off

No power supply is present or the power supply has failed.

Steady green

The power supply is operating correctly.

10/100/1000BASE-T copper port LED

10/100/1000BASE-T

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is receiving and sending data at 10 Mbps or 100 Mbps.

1000BASE-X fiber port LED

1000BASE-X

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

10GE fiber port LED

10GBASE-R

Off

No link is present.

Steady green

A 10 Gbps link is present.

Flashing green

The port is receiving and sending data at 10 Gbps.

1000BASE-X fiber port LED (combo interfaces)

1000BASE-X

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

10/100/1000BASE-T copper port LED (combo interfaces)

10/100/1000BASE-T

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is receiving and sending data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is receiving and sending data at 10 Mbps or 100 Mbps.

Interface module status LED

Slot1, Slot2

Off

No interface module is present or the interface module has failed.

Steady green

The interface module is operating correctly.

 

9 Appendix C  Cables

Console cable

A console cable is an 8-core shielded cable with a crimped RJ-45 connector at one end and a DB-9 female connector at the other end. The RJ-45 connector is for connecting to the console port of the firewall, and the DB-9 female connector is for connecting to the serial port on the configuration terminal.

Figure9-1 Console cable

 

Table9-1 Console cable pinouts

RJ-45

Signal

Direction

DB-9

1

RTS

7

2

DTR

4

3

TXD

3

4

CD

1

5

GND

-

5

6

RXD

2

7

DSR

6

8

CTS

8

 

Ethernet twisted pair cable

Introduction

An Ethernet twisted pair cable consists of four pairs of insulated copper wires twisted together. Every wire uses a different color, and has a diameter of about 1 mm (0.04 in). A pair of twisted copper cables can cancel the electromagnetic radiation of each other, and reduce interference of external sources. An Ethernet twisted pair cable mainly transmits analog signals and is advantageous in transmitting data over shorter distances. It is the commonly used transmission media of the Ethernet. The maximum transmission distance of the Ethernet twisted pair cable is 100 m (328.08 ft). To extend the transmission distance, you can connect two twisted pair cable segments with a repeater. At most four repeaters can be added, which means five segments can be joined together to provide a transmission distance of 500 m (1640.42 ft).

Ethernet twisted pair cables can be classified into category 3, category 4, category 5, category 5e, category 6, and category 7 cables based on performance. In LANs, category 5, category 5e, and category 6 are commonly used.

Table9-2 Description for commonly used Ethernet twisted pair cables

Type

Description

Category 5

Suitable for data transmission at a maximum speed of 100 Mbps

Category 5e

Suitable for data transmission at a maximum speed of 1000 Mbps

Category 6

Suitable for data transmission at a speed higher than 1 Gbps

 

Based on whether a metal shielding is used, Ethernet twisted pair cables can be classified into shielded twisted pair (STP) and unshielded twisted pair (UTP). An STP cable provides a metallic braid between the twisted pairs and the outer jacket. This metallic braid helps reduce radiation, prevent information from being listened, and eliminate external electromagnetic interference (EMI) of external sources. STPs have strict application requirements and are expensive although they provide better EMI prevention performance than UTPs, so in most LANs, UTPs are commonly used.

An Ethernet twisted pair cable connects network devices through the RJ-45 connectors at the two ends. Figure9-2 shows the pinouts of an RJ-45 connector.

Figure9-2 RJ-45 connector pinout

 

 

NOTE:

The RJ-45 Ethernet ports of the firewall use category 5 or higher Ethernet twisted pair cables for connection.

 

EIA/TIA cabling specifications define two standards, 568A and 568B, for cable pinouts.

·     Standard 568A—pin 1: white/green stripe, pin 2: green solid, pin 3: white/orange stripe, pin 4: blue solid, pin 5: white/blue stripe, pin 6: orange solid, pin 7: white/brown stripe, pin 8: brown solid.

·     Standard 568B—pin 1: white/orange stripe, pin 2: orange solid, pin 3: white/green stripe, pin 4: blue solid, pin 5: white/blue stripe, pin 6: green solid, pin 7: white/brown stripe, pin 8: brown solid.

Ethernet twisted pair cables can be classified into straight-through and crossover cables based on their pinouts.

·     Straight-throughThe pinouts at both ends are T568B compliant, as shown in Figure9-3.

·     CrossoverThe pinouts are T568B compliant at one end and T568A compliant at the other end, as shown in Figure9-4.

Figure9-3 Straight-through cable

 

Figure9-4 Crossover cable

 

Select an Ethernet twisted pair cable according to the RJ-45 Ethernet port type on your device. An RJ-45 Ethernet port can be MDI (for routers and PCs) or MDIX (for switches). Table9-3 and Table9-4 show their pinouts.

Table9-3 RJ-45 MDI port pinouts

Pin

10BASE-T/100BASE-TX

1000BASE-T

Signal

Function

Signal

Function

1

Tx+

Sends data

BIDA+

Bi-directional data cable A+

2

Tx-

Sends data

BIDA-

Bi-directional data cable A-

3

Rx+

Receives data

BIDB+

Bi-directional data cable B+

4

Reserved

N/A

BIDC+

Bi-directional data cable C+

5

Reserved

N/A

BIDC-

Bi-directional data cable C-

6

Rx-

Receives data

BIDB-

Bi-directional data cable B-

7

Reserved

N/A

BIDD+

Bi-directional data cable D+

8

Reserved

N/A

BIDD-

Bi-directional data cable D-

 

Table9-4 RJ-45 MDIX port pinouts

Pin

10BASE-T/100BASE-TX

1000BASE-T

Signal

Function

Signal

Function

1

Rx+

Receives data

BIDB+

Bi-directional data cable B+

2

Rx-

Receives data

BIDB-

Bi-directional data cable B-

3

Tx+

Sends data

BIDA+

Bi-directional data cable A+

4

Reserved

N/A

BIDD+

Bi-directional data cable D+

5

Reserved

N/A

BIDD-

Bi-directional data cable D-

6

Tx-

Sends data

BIDA-

Bi-directional data cable A-

7

Reserved

N/A

BIDC+

Bi-directional data cable C+

8

Reserved

N/A

BIDC-

Bi-directional data cable C-

 

To ensure normal communication, the pins for sending data on one port must correspond to the pins for receiving data on the peer port. When both of the ports on the two devices are MDI or MDIX, use a crossover Ethernet cable; when one port is MDI and the other is MDIX, use a straight-through Ethernet cable. To summarize, straight-through and crossover cables connect the following devices:

·     Straight-through cables connect devices of different types—for example, router to PC and router to switch.

·     Crossover cables connect devices of the same type—for example, switch to switch, router to router, and PC to PC.

If an RJ-45 Ethernet port is enabled with MDI/MDIX autosensing, it can automatically negotiate pin roles.

 

 

NOTE:

The RJ-45 Ethernet ports on the firewall support MDI/MDIX autosensing.

 

Making an Ethernet twisted pair cable

1.     Cut the cable to a required length with the crimping tool.

2.     Strip off an appropriate length of the cable sheath. The length is typically that of the RJ-45 connector.

3.     Untwist the pairs so that they can lay flat, and arrange the colored wires based on the wiring specifications.

4.     Cut the top of the wires even with one another. Insert the wires into the RJ-45 connector and make sure the wires extend to the front of the RJ-45 connector and make good contact with the metal contacts in the RJ-45 connector and in the correct order.

5.     Crimp the RJ-45 connector with the crimping tool until you hear a click.

6.     Use a cable tester to verify the connectivity of the cable.

Optical fiber

Optical fibers feature low loss and long transmission distance.

Optical fibers can be classified into single mode fibers and multi-mode fibers. A single mode fiber (with yellow jacket) carries only a single ray of light; a multi-mode fiber (with orange jacket) carries multiple modes of lights.

Table9-5 Characteristics of single mode and multi-mode optical fibers

Item

Single mode fiber

Multi-mode fiber

Core

Small core (10 micrometers or less)

Larger core than single mode fiber (50 micrometers, 62.5 micrometers or greater)

Dispersion

Less dispersion

Allows greater dispersion and therefore, signal loss exists.

Light source and transmission distance

Uses lasers as the light source often within campus backbones for distance of several thousand meters

Uses LEDs as the light source often within LANs or distances of a couple hundred meters within a campus network

 

Table9-6 Allowed maximum tensile force and crush load

Period of force

Tensile load (N)

Crush load (N/mm)

Short period

150

500

Long term

80

100

 

Fiber connectors are indispensable passive components in an optical fiber communication system. They allow the removable connection between optical channels, which makes the optical system debugging and maintenance more convenient. There are multiple types of fiber connectors. Figure9-5 shows an LC connector.

Figure9-5 Appearance of an LC connector

 

Follow these guidelines when you connect an optical fiber:

·     Before connecting an optical fiber, make sure the connector and cable type match the interface module.

·     The fiber Ethernet port of the firewall supports only the LC connector.

·     Fiber connectors are fitted with dust caps. Keep the dust caps secure when the fiber connectors are in use. Install dust caps when the fiber connectors are not in use to avoid damage to their end face. Replace the dust cap if it is loose or polluted.

·     Before connecting an optical fiber, use dust free paper and absolute alcohol to clean the end face of the two fiber connectors. You can brush the end faces only in one direction.

·     Never bend or curve a fiber when connecting it.

·     If the fiber has to pass through a metallic board hole, when passing through a metallic board hole or bending along the acute side of mechanical parts, the fiber must wear jackets or cushions.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网