1 Product models and technical specifications
Product models
H3C S6520X-EI switch series includes the following models:
· S6520X-30QC-EI
· S6520X-54QC-EI
· S6520X-30HC-EI
· S6520X-54HC-EI
· S6520X-30HF-EI
· S6520X-54HF-EI
H3C S6520X-HI switch series includes the following models:
· S6520X-30QC-HI
· S6520X-54QC-HI
· S6520X-30HC-HI
· S6520X-54HC-HI
· S6520X-30HF-HI
· S6520X-54HF-HI
Technical specifications
Table1-1 Technical specifications (1)
Item |
S6520X-30QC-EI S6520X-30QC-HI |
S6520X-54QC-EI S6520X-54QC-HI |
S6520X-30HC-EI S6520X-30HC-HI |
S6520X-54HC-EI S6520X-54HC-HI |
Dimensions (H × W × D) |
43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in) |
43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in) |
43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in) |
43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 in) |
Weight |
≤ 7.0 kg (15.43 lb) |
≤ 7.2 kg (15.87 lb) |
≤ 7.4 kg (16.31 lb) |
≤ 7.6 kg (16.75 lb) |
Console port |
· 1 × micro USB console port · 1 × serial console port Only the micro USB console port is available when you connect both ports. |
|||
USB port |
1 |
1 |
1 |
1 |
Management Ethernet port |
1 |
1 |
1 |
1 |
QSFP+ port |
2 |
2 |
N/A |
N/A |
SFP+ port |
24 |
48 |
24 |
48 |
QSFP28 port |
N/A |
N/A |
2 |
2 |
Expansion slot |
2, on the rear panel |
2, on the rear panel |
2, on the rear panel |
2, on the rear panel |
Power supply slot |
2, on the rear panel |
2, on the rear panel |
2, on the rear panel |
2, on the rear panel |
Fan tray slot |
2, on the rear panel |
2, on the rear panel |
2, on the rear panel |
2, on the rear panel |
Input voltage |
· AC input for the PSR250-12A/PSR250-12A1 power supply: ¡ Rated voltage range: 100 to 240 VAC @ 50/60 Hz ¡ Max voltage range: 90 to 264 VAC @ 47 to 63 Hz · High-voltage DC input for the PSR250-12A/PSR250-12A1 power supply: ¡ Rated voltage range: 240 VDC ¡ Max voltage range: 180 to 320 VDC · PSR450-12D power supply: ¡ Rated voltage range: –48 to –60 VDC ¡ Max voltage range: –36 to –72 VDC |
|||
Minimum power consumption |
· 38 W with one PSR250-12A/PSR250-12A1 · 43 W with two PSR250-12A/PSR250-12A1 · 40 W with one PSR450-12D · 45 W with two PSR450-12D |
· 39 W with one PSR250-12A/PSR250-12A1 · 44 W with two PSR250-12A/PSR250-12A1 · 41 W with one PSR450-12D · 46 W with two PSR450-12D |
· 38 W with one PSR250-12A/PSR250-12A1 · 43 W with two PSR250-12A/PSR250-12A1 · 40 W with one PSR450-12D · 45 W with two PSR450-12D |
· 44 W with one PSR250-12A/PSR250-12A1 · 49 W with two PSR250-12A/PSR250-12A1 · 46 W with one PSR450-12D · 51 W with two PSR450-12D |
Maximum power consumption |
· 179 W with one PSR250-12A/PSR250-12A1 · 183 W with two PSR250-12A/PSR250-12A1 · 181 W with one PSR450-12D · 185 W with two PSR450-12D |
· 231 W with one PSR250-12A/PSR250-12A1 · 234 W with two PSR250-12A/PSR250-12A1 · 233 W with one PSR450-12D · 236 W with two PSR450-12D |
· 197 W with one PSR250-12A/PSR250-12A1 · 200 W with two PSR250-12A/PSR250-12A1 · 199 W with one PSR450-12D · 202 W with two PSR450-12D |
· 249 W with one PSR250-12A/PSR250-12A1 · 251 W with two PSR250-12A/PSR250-12A1 · 251 W with one PSR450-12D · 253 W with two PSR450-12D |
Melting current of power supply fuse |
· PSR250-12A/PSR250-12A1: ¡ AC input: 6.3 A/250 VAC ¡ High-voltage DC input: 6.3 A/250 VDC · PSR450-12D: 20 A/125 V |
|||
Operating temperature |
–5°C to +45°C (23°F to 113°F) |
|||
Humidity |
5% RH to 95% RH, noncondensing |
|||
Security compliance |
UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1 |
Table1-2 Technical specifications (2)
Item |
S6520X-30HF-EI |
S6520X-54HF-EI |
S6520X-30HF-HI |
S6520X-54HF-HI |
Dimensions (H × W × D) |
44 × 440 × 360 mm (1.73 × 17.32 × 14.17 in) |
44 × 440 × 360 mm (1.73 × 17.32 × 14.17 in) |
44 × 440 × 360 mm (1.73 × 17.32 × 14.17 in) |
44 × 440 × 360 mm (1.73 × 17.32 × 14.17 in) |
Weight |
≤ 5.5 kg (12.13 lb) |
≤ 6.0 kg (13.23 lb) |
≤ 6.0 kg (13.23 lb) |
≤ 6.5 kg (14.33 lb) |
Console port |
1 × serial console port |
|||
Management Ethernet port |
1 |
1 |
1 |
1 |
USB port |
1 |
1 |
1 |
1 |
SFP+ port |
24 |
48 |
24 |
48 |
QSFP28 port |
6 |
6 |
6 |
6 |
Fan tray slot |
3 |
3 |
3 |
3 |
Power supply slot |
2 |
2 |
2 |
2 |
Input voltage |
AC input for the PSR180-12A-F/PSR180-12A-B power supply: · Rated voltage range: 100 to 240 VAC @ 50/60 Hz · Max voltage range: 90 to 264 VAC @ 47 to 63 Hz |
|||
Minimum power consumption |
· 29 W with one PSR180-12A-F/PSR180-12A-B · 35 W with two PSR180-12A-F/PSR180-12A-B |
· 29 W with one PSR180-12A-F/PSR180-12A-B · 36 W with two PSR180-12A-F/PSR180-12A-B |
· 38 W with one PSR180-12A-F/PSR180-12A-B · 46 W with two PSR180-12A-F/PSR180-12A-B |
· 36 W with one PSR180-12A-F/PSR180-12A-B · 44 W with two PSR180-12A-F/PSR180-12A-B |
Maximum power consumption |
· 131 W with one PSR180-12A-F/PSR180-12A-B · 134 W with two PSR180-12A-F/PSR180-12A-B |
· 162 W with one PSR180-12A-F/PSR180-12A-B · 163 W with two PSR180-12A-F/PSR180-12A-B |
· 143 W with one PSR180-12A-F/PSR180-12A-B · 145 W with two PSR180-12A-F/PSR180-12A-B |
· 176 W with one PSR180-12A-F/PSR180-12A-B · 177 W with two PSR180-12A-F/PSR180-12A-B |
Melting current of power supply fuse |
6.3 A @ 250 VAC |
|||
Operating temperature |
–5°C to +45°C (23°F to 113°F) |
|||
Humidity |
5% RH to 95% RH, noncondensing |
|||
Safety specification compliance |
UL 62368-1/EN 62368-1/IEC 62368-1/UL 60950-1/EN 60950-1/IEC 60950-1/GB4943.1 |
2 Chassis views
S6520X-30QC-EI & S6520X-30QC-HI
Figure2-1 Front panel
(1) SFP+ port |
(2) SFP+ port LED |
(3) Management Ethernet port |
(4) Console port (CONSOLE) |
(5) Micro USB console port |
(6) Mode LED (MODE) |
(7) USB port |
(8) Mode button |
(9) System status LED (SYS) |
(10) Expansion card 2 status LED (SLOT2) |
(11) Expansion card 1 status LED (SLOT1) |
(12) Power supply 2 status LED (PWR2) |
(13) Power supply 1 status LED (PWR1) |
(14) QSFP+ port LED |
(15) QSFP+ port |
(16) Management Ethernet port LED (ACT/LINK) |
(1) Grounding screw |
(2) Fan tray 1 (FAN1) |
(3) Expansion card 1 (SLOT1) |
(4) Expansion card 2 (SLOT2) |
(5) Fan tray 2 (FAN2) |
(6) Power supply 1 (PWR1) |
(7) Power supply 2 (PWR2) |
The S6520X-30QC-EI and S6520X-30QC-HI switches come with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-2, two PSR250-12A1 power supplies are installed in the power supply slots.
The S6520X-30QC-EI and S6520X-30QC-HI switches come with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-2, two LSWM1FANSCBE fan trays are installed in the fan tray slots.
The S6520X-30QC-EI and S6520X-30QC-HI switches come with a filler panel in each expansion slot. You can select expansion cards for the switch as required. In Figure2-2, two LSWM4SP8PM interface modules are installed in the expansion slots.
S6520X-54QC-EI & S6520X-54QC-HI
Figure2-3 Front panel
(1) SFP+ port |
(2) SFP+ port LED |
(3) Management Ethernet port |
(4) Console port (CONSOLE) |
(5) Micro USB console port |
(6) Mode LED (MODE) |
(7) USB port |
(8) Mode button |
(9) System status LED (SYS) |
(10) Expansion card 2 status LED (SLOT2) |
(11) Expansion card 1 status LED (SLOT1) |
(12) Power supply 2 status LED (PWR2) |
(13) Power supply 1 status LED (PWR1) |
(14) QSFP+ port LED |
(15) QSFP+ port |
(16) Management Ethernet port LED (ACT/LINK) |
(1) Grounding screw |
(2) Fan tray 1 (FAN1) |
(3) Expansion card 1 (SLOT1) |
(4) Expansion card 2 (SLOT2) |
(5) Fan tray 2 (FAN2) |
(6) Power supply 1 (PWR1) |
(7) Power supply 2 (PWR2) |
The S6520X-54QC-EI and S6520X-54QC-HI switches come with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-4, two PSR250-12A1 power supplies are installed in the power supply slots.
The S6520X-54QC-EI and S6520X-54QC-HI switches come with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-4, two LSWM1FANSCBE fan trays are installed in the fan tray slots.
The S6520X-54QC-EI and S6520X-54QC-HI switches come with a filler panel in each expansion slot. You can select expansion cards for the switch as required. In Figure2-4, two LSWM4SP8PM interface modules are installed in the expansion slots.
S6520X-30HC-EI & S6520X-30HC-HI
Figure2-5 Front panel
(1) SFP+ port |
(2) SFP+ port LED |
(3) Management Ethernet port |
(4) Console port (CONSOLE) |
(5) Micro USB console port |
(6) Mode LED (MODE) |
(7) USB port |
(8) Mode button |
(9) System status LED (SYS) |
(10) Expansion card 2 status LED (SLOT2) |
(11) Expansion card 1 status LED (SLOT1) |
(12) Power supply 2 status LED (PWR2) |
(13) Power supply 1 status LED (PWR1) |
(14) QSFP28 port LED |
(15) QSFP28 port |
(16) Management Ethernet port LED (ACT/LINK) |
(1) Grounding screw |
(2) Fan tray 1 (FAN1) |
(3) Expansion card 1 (SLOT1) |
(4) Expansion card 2 (SLOT2) |
(5) Fan tray 2 (FAN2) |
(6) Power supply 1 (PWR1) |
(7) Power supply 2 (PWR2) |
The S6520X-30HC-EI and S6520X-30HC-HI switches come with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-6, two PSR250-12A1 power supplies are installed in the power supply slots.
The S6520X-30HC-EI & S6520X-30HC-HI switches come with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-6, two LSWM1FANSCBE fan trays are installed in the fan tray slots.
The S6520X-30HC-EI & S6520X-30HC-HI switches come with a filler panel in each expansion slot. You can select expansion cards for the switch as required. In Figure2-6, two LSWM4SP8PM interface modules are installed in the expansion slots.
S6520X-54HC-EI & S6520X-54HC-HI
Figure2-7 Front panel
(1) SFP+ port |
(2) SFP+ port LED |
(3) Management Ethernet port |
(4) Console port (CONSOLE) |
(5) Micro USB console port |
(6) Mode LED (MODE) |
(7) USB port |
(8) Mode button |
(9) System status LED (SYS) |
(10) Expansion card 2 status LED (SLOT2) |
(11) Expansion card 1 status LED (SLOT1) |
(12) Power supply 2 status LED (PWR2) |
(13) Power supply 1 status LED (PWR1) |
(14) QSFP28 port LED |
(15) QSFP28 port |
(16) Management Ethernet port LED (ACT/LINK) |
(1) Grounding screw |
(2) Fan tray 1 (FAN1) |
(3) Expansion card 1 (SLOT1) |
(4) Expansion card 2 (SLOT2) |
(5) Fan tray 2 (FAN2) |
(6) Power supply 1 (PWR1) |
(7) Power supply 2 (PWR2) |
The S6520X-54HC-EI and S6520X-54HC-HI switches come with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-8, two PSR250-12A1 power supplies are installed in the power supply slots.
The S6520X-54HC-EI and S6520X-54HC-HI switches come with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-4, two LSWM1FANSCBE fan trays are installed in the fan tray slots.
The S6520X-54HC-EI and S6520X-54HC-HI switches come with a filler panel in each expansion slot. You can select expansion cards for the switch as required. In Figure2-4, two LSWM4SP8PM interface modules are installed in the expansion slots.
S6520X-30HF-EI & S6520X-30HF-HI
Figure2-9 Front panel
(1) SFP+ port |
(2) SFP+ port LED |
(3) QSFP28 port |
(4) QSFP28 port LED |
(5) System status LED (SYS) |
(1) Management Ethernet port |
(2) Console port (CONSOLE) |
(3) USB port |
(4) Fan tray 1 (FAN1) |
(5) Fan tray 2 (FAN2) |
(6) Fan tray 3 (FAN3) |
(7) Power supply 1 (PWR1) |
(8) Power supply 2 (PWR2) |
(9) Reset button (RESET) |
(10) Management Ethernet port LED (ACT/LINK) |
(11) Grounding screw |
The S6520X-30HF-EI and S6520X-30HF-HI switches come with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-10, two PSR180-12A-B power supplies are installed in the power supply slots.
The S6520X-30HF-EI and S6520X-30HF-HI switches come with the three fan tray slots empty. You must install three fan trays of the same model for the switch. In Figure2-10, three LSPM1FANSB-SN fan trays are installed in the fan tray slots.
The S6520X-30HF-EI and S6520X-30HF-HI switches come with a reset button RESET. You can press the button to reboot the device.
S6520X-54HF-EI & S6520X-54HF-HI
Figure2-11 Front panel
(1) SFP+ port |
(2) SFP+ port LED |
(3) QSFP28 port |
(4) QSFP28 port LED |
(5) System status LED (SYS) |
(1) Management Ethernet port |
(2) Console port (CONSOLE) |
(3) USB port |
(4) Fan tray 1 (FAN1) |
(5) Fan tray 2 (FAN2) |
(6) Fan tray 3 (FAN3) |
(7) Power supply 1 (PWR1) |
(8) Power supply 2 (PWR2) |
(9) Reset button (RESET) |
(10) Management Ethernet port LED (ACT/LINK) |
(11) Grounding screw |
The S6520X-54HF-EI and S6520X-54HF-HI switches come with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-12, two PSR180-12A-B power supplies are installed in the power supply slots.
The S6520X-54HF-EI and S6520X-54HF-HI switches come with the three fan tray slots empty. You must install three fan trays of the same model for the switch. In Figure2-12, three LSPM1FANSB-SN fan trays are installed in the fan tray slots.
The S6520X-54HF-EI and S6520X-54HF-HI switches come with a reset button (RESET). You can press the button to reboot the device.
3 Removable components and compatibility matrixes
Table3-1 Compatibility matrix between switches and removable components
FRU model |
S6520X-30QC-EI S6520X-30QC-HI S6520X-54QC-EI S6520X-54QC-HI |
S6520X-30HC-EI S6520X-30HC-HI S6520X-54HC-EI S6520X-54HC-HI |
S6520X-30HF-EI S6520X-54HF-EI S6520X-30HF-HI S6520X-54HF-HI |
Removable power supplies |
|||
PSR250-12A |
Supported |
Supported |
Not supported |
PSR250-12A1 |
Supported |
Supported |
Not supported |
PSR450-12D |
Supported |
Supported |
Not supported |
PSR180-12A-F |
Not supported |
Not supported |
Supported |
PSR180-12A-B |
Not supported |
Not supported |
Supported |
Removable fan trays |
|||
LSWM1FANSCE |
Supported |
Supported |
Not supported |
LSWM1FANSCBE |
Supported |
Supported |
Not supported |
LSPM1FANSA-SN |
Not supported |
Not supported |
Supported |
LSPM1FANSB-SN |
Not supported |
Not supported |
Supported |
Expansion cards |
|||
LSWM2QP2P |
Supported |
Supported |
Not supported |
LSWM2SP8P |
Supported |
Supported |
Not supported |
LSWM4SP8PM |
Supported |
Supported |
Not supported |
LSWM2ZQP2P |
Not supported |
Supported |
Not supported |
LSWM2ZSP8P |
Not supported |
Supported |
Not supported |
LSPM6FWD |
Supported |
Supported |
Not supported |
LSPM6FWD8 |
Supported |
Supported |
Not supported |
LSWM2XMGT8P |
Supported |
Supported |
Not supported |
LSWM2MGT8P |
Supported |
Supported |
Not supported |
LSWM2ZSP2P |
Supported |
Supported |
Not supported |
LSWM2SP2PB |
Supported |
Supported |
Not supported |
LSWM2SP4PB |
Supported |
Supported |
Not supported |
Removable power supplies
The switch uses removable power supplies and supports the PSR250-12A, PSR250-12A1, PSR450-12D, PSR180-12A-F, and PSR180-12A-B power supplies.
You can install one power supply, or two power supplies in 1+1 redundancy for the switch.
Table3-2 Power supplies available for the switch
Power supply model |
AC or DC input |
Specifications |
Reference |
PSR250-12A PSR250-12A1 |
AC input |
· Rated input voltage range: 100 to 240 VAC @ 50/60 Hz · Max input voltage range: 90 to 264 VAC @ 47 to 63 Hz · Max output power: 250 W |
H3C PSR250-12A & PSR250-12A1 Power Modules User Manual |
High-voltage DC input |
· Rated input voltage range: 240 VDC · Max input voltage range: 180 to 320 VDC · Max output power: 250 W |
||
PSR450-12D |
DC input |
· Rated input voltage range: –48 to –60 VDC · Max input voltage range: –36 to –72 VDC · Max output power: 450 W |
H3C PSR450 Power Supply Series User Guide |
PSR180-12A-F |
AC input |
· Rated input voltage range: 100 to 240 VAC @ 56/60 Hz · Max input voltage range: 90 to 264 VAC @ 47 to 63 Hz · Max output power: 180 W · Melting current of power supply fuse: 6.3 A/250 V |
H3C PSR180-12A & PSR180-12D Power Supply Series User Manual |
PSR180-12A-B |
AC input |
· Rated input voltage range: 100 to 240 VAC @ 56/60 Hz · Max input voltage range: 90 to 264 VAC @ 47 to 63 Hz · Max output power: 180 W · Melting current of power supply fuse: 6.3 A/250 V |
H3C PSR180-12A & PSR180-12D Power Supply Series User Manual |
Removable fan trays
CAUTION: You can power on the switch only when the switch has all fan trays of the same model installed. |
The switch uses removable fan trays and supports the LSWM1FANSCE, LSWM1FANSCBE, LSPM1FANSA-SN, and LSPM1FANSB-SN fan trays.
Table3-3 LSWM1FANSCE and LSWM1FANSCBE fan tray specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 40 × 56 mm (1.57 × 1.57 × 2.20 in) |
Fan speed |
21000 R.P.M |
Max airflow |
26 CFM |
Input voltage |
12 V |
Maximum power consumption |
27.72 W |
Airflow direction |
· LSWM1FANSCE—From the power supply side to the port side · LSWM1FANSCBE—From the port side to the power supply side |
Reference |
H3C LSWM1FANSCE & LSWM1FANSCBE Fan Trays User Guide |
Table3-4 LSPM1FANSA-SN and LSPM1FANSB-SN fan tray specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 40.6 × 105 mm (1.57 × 1.60 × 4.13 in) |
Fan speed |
20000 R.P.M |
Max airflow |
20 CFM |
Input voltage |
12 V |
Maximum power consumption |
9.8 W |
Airflow direction |
· LSPM1FANSA-SN—From the power supply side to the port side · LSPM1FANSB-SN—From the port side to the power supply side |
Reference |
H3C LSPM1FANSA-SN & LSPM1FANSB-SN Fan Trays User Guide |
Expansion cards
Table3-5 Expansion card specifications
Item |
Specifications |
LSWM2QP2P |
|
Description |
2-port 40GE QSFP+ interface module |
Port type and quantity |
Two 40 Gbps QSFP+ fiber ports |
Available transceiver modules and cables |
QSFP+ transceiver modules and cables described in Table4-9, Table4-10, and Table4-11. |
Reference |
H3C LSWM2QP2P Interface Card User Manual |
LSWM2SP8P |
|
Description |
8-port 10GE SFP+ interface module |
Port type and quantity |
Eight 1/10 Gbps SFP+ fiber ports |
Available transceiver modules and cables |
See GE SFP transceiver modules and cables described in Table4-3 and 10-GE SFP+ transceiver modules and cables described in Table4-4 and Table4-5. |
Reference |
H3C LSWM2SP8PM & LSWM2SP8P Interface Cards User Manual |
LSWM4SP8PM |
|
Description |
8-port 10GE SFP+ interface module |
Port type and quantity |
Eight 1/10 Gbps SFP+ fiber ports |
Available transceiver modules and cables |
See GE SFP transceiver modules and cables described in Table4-3 and 10-GE SFP+ transceiver modules and cables described in Table4-4 and Table4-5. |
Reference |
H3C LSWM4SP8PM Interface Card User Manual |
LSWM2ZQP2P |
|
Description |
2-port 100GE QSFP28 interface module |
Port type and quantity |
Two 40/100 Gbps QSFP28 fiber ports |
Available transceiver modules and cables |
See QSFP+ transceiver modules and cables described in Table4-9, Table4-10, and Table4-11 and QSFP28 transceiver modules and cables described in Table4-13, Table4-14, and Table4-15. |
Reference |
H3C LSWM2ZQP2P Interface Card User Manual |
LSWM2ZSP8P |
|
Description |
8-port 25GE SFP28 interface module |
Port type and quantity |
Eight 25 Gbps SFP28 fiber ports |
Available transceiver modules and cables |
See SFP28 transceiver modules and cables described in Table4-7 and Table4-8. |
Reference |
H3C LSWM2ZSP8P Interface Card User Manual |
LSPM6FWD |
|
Description |
The card is a fourth-generation high performance firewall module. It provides features including firewall, VPN, content filtering, content identification, URL filtering, and NAT. By using this card on a switch, you can enhance the switch security capabilities without changing the network topology. |
Reference |
H3C LSPM6FWD Card Manual |
LSPM6FWD8 |
|
Description |
The card is a fourth-generation high performance firewall module. It provides features including firewall, VPN, content filtering, content identification, URL filtering, and NAT. By using this card on a switch, you can enhance the switch security capabilities without changing the network topology. |
Reference |
H3C LSPM6FWD8 Card Manual |
LSWM2XMGT8P |
|
Description |
8-port 1/2.5/5/10GBASE-T interface module |
Port type and quantity |
Eight 10G/5G/2.5G/1000BASE-T autosensing Ethernet ports |
Port specifications |
See Table4-16 for the port specifications. |
Reference |
H3C LSWM2MGT8P & LSWM2XMGT8P Interface Cards User Manual |
LSWM2MGT8P |
|
Description |
8-port 1/2.5/5GBASE-T interface module |
Port type and quantity |
Eight 5G/2.5G/1000BASE-T autosensing Ethernet ports |
Port specifications |
See Table4-17 for the port specifications. |
Reference |
H3C LSWM2MGT8P & LSWM2XMGT8P Interface Cards User Manual |
LSWM2ZSP2P |
|
Description |
2-port 25G SFP28 Ethernet optical interface module |
Port type and quantity |
Two 25G SFP28 fiber ports |
Available transceiver modules and cables |
See the 25G SFP28 transceiver modules and SFP28 cables described in Table4-7 and Table4-8. |
Reference |
H3C LSWM2ZSP2P Interface Card User Manual |
LSWM2SP2PB |
|
Description |
2-port 10G SFP+ Ethernet optical interface module |
Port type and quantity |
Two 1G/10G SFP+ fiber ports |
Available transceiver modules and cables |
· See the GE SFP transceiver modules and SFP cables described in Table4-3. · See the 10-GE SFP+ transceiver modules and SFP+ cables described in Table4-4, Table4-5, and Table4-6. |
Reference |
H3C LSWM2SP2PB & LSWM2SP4PB Interface Cards User Manual |
LSWM2SP4PB |
|
Description |
4-port 10G SFP+ Ethernet optical interface module |
Port type and quantity |
Four 1G/10G SFP+ fiber ports |
Available transceiver modules and cables |
· See the GE SFP transceiver modules and SFP cables described in Table4-3. · See the 10-GE SFP+ transceiver modules and SFP+ cables described in Table4-4, Table4-5, and Table4-6. |
Reference |
H3C LSWM2SP2PB & LSWM2SP4PB Interface Cards User Manual |
Connecting cables to the ports on interface modules
To connect cables to the ports on interface modules, follow these guidelines:
· Do not bundle cables in their first 20 m (65.62 ft).
· Separate power cords and twisted pair cables at and around the distribution frame.
· For ports adjacent to one another on the device, the peer ports on the distribution frame is preferably not adjacent, for example:
· If the device connects to one distribution frame, connect port 1 on the device to port 1 on the distribution frame and port 2 on the device to port 3 on the distribution frame.
· If the device connects to two distribution frames, connect port 1 on the device to port 1 on distribution frame 1 and port 2 on the device to port 1 on distribution frame 2.
· Keep the device and cables away from the interference source, such as a two-way radio and a high-power variable-frequency drive.
4 Ports and LEDs
Ports
Console port
Table4-1 Console port specifications
Item |
Serial console port |
Micro USB console port |
Connector type |
RJ-45 |
Micro USB Type B |
Compliant standard |
EIA/TIA-232 |
USB 2.0 |
Transmission baud rate |
9600 bps (default) to 115200 bps |
|
Services |
· Provides connection to an ASCII terminal. · Provides connection to the serial port of a local PC running terminal emulation program. |
Provides connection to the USB port of a local PC running terminal emulation program. |
Compatible devices |
All device models. |
· S6520X-30QC-EI · S6520X-54QC-EI · S6520X-30HC-EI · S6520X-54HC-EI · S6520X-30QC-HI · S6520X-54QC-HI · S6520X-30HC-HI · S6520X-54HC-HI |
You cannot use both console ports at the same time. Only the Micro USB console port works when you connect both ports. |
Management Ethernet port
You can connect the management Ethernet port to a PC or management station for loading and debugging software or remote management.
Table4-2 Management Ethernet port specifications
Item |
Specification |
Connector type |
RJ-45 |
Port transmission rate |
· 10/100 Mbps, half/full duplex, MDI/MDI-X autosensing · 1000 Mbps, full duplex, MDI/MDI-X autosensing |
Transmission medium and max transmission distance |
100 m (328.08 ft) over category-5 twisted pair cable |
Functions and services |
Switch software and Boot ROM upgrade, network management |
Compatible devices |
All device models |
USB port
The switch has one OHC-compliant USB2.0 port that can upload and download data at a rate up to 480 Mbps. You can use this USB port to access the file system on the flash of the switch, for example, to upload or download application and configuration files.
|
NOTE: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee the correct operation of USB devices from all vendors on the switch. If a USB device fails to operate on the switch, replace it with one from another vendor. |
SFP+ port
The switch provides fixed SFP+ ports on the front panel. The LSWM2SP2PB, LSWM2SP4PB, LSWM4SP8PM, and LSWM2SP8P interface modules also provide SFP+ ports. To connect peer SFP+ ports over a long distance, use SFP/SFP+ transceiver modules and fibers. To connect peer SFP+ ports over a short distance, use SFP/SFP+ cables. You can install GE SFP transceiver modules and cables in Table4-3, 10-GE SFP+ transceiver modules in Table4-4, and 10-GE SFP+ cables in Table4-5 in the SFP+ ports.
Table4-3 GE SFP transceiver modules and cables available for the SFP+ ports
GE SFP transceiver module and cable |
Central wavelength (nm) |
Connector |
Cable/Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
GE SFP transceiver modules |
|||||
SFP-GE-T |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
SFP-GE-T-D |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
SFP-GE-SX-MM850-A |
850 |
LC |
Multi-mode, 50/125 |
500 |
550 m (1804.46 ft) |
400 |
500 m (1640.42 ft) |
||||
Multi-mode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
160 |
220 m (721.78 ft) |
||||
SFP-GE-SX-MM850-D |
850 |
LC |
Multi-mode, 50/125 |
500 |
550 m (1804.46 ft) |
400 |
500 m (1640.42 ft) |
||||
Multi-mode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
160 |
220 m (721.78 ft) |
||||
SFP-GE-SX-MM850-S |
850 |
LC |
Multi-mode, 50/125 |
500 |
550 m (1804.46 ft) |
400 |
500 m (1640.42 ft) |
||||
Multi-mode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
160 |
220 m (721.78 ft) |
||||
SFP-GE-LX-SM1310-A |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
Multi-mode, 50/125 |
500 or 400 |
550 m (1804.46 ft) |
|||
Multi-mode, 62.5/125 |
500 |
550 m (1804.46 ft) |
|||
SFP-GE-LX-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LX-SM1310-S |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LH20-SM1310-I |
1310 |
LC |
Single-mode, 9/125 |
N/A |
20 km (12.43 miles) |
SFP-GE-LH40-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1310-I |
1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH80-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-GE-LH80-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-GE-LH100-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
100 km (62.14 miles) |
SFP-GE-LX-SM1310-BIDI |
TX: 1310 RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LX-SM1490-BIDI |
TX: 1490 RX: 1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-GE-LH40-SM1310-BIDI |
TX: 1310 RX: 1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH40-SM1550-BIDI |
TX: 1550 RX: 1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-GE-LH70-SM1490-BIDI |
TX: 1490 RX: 1550 |
LC |
Single-mode, 9/125 |
N/A |
70 km (43.50 miles) |
SFP-GE-LH70-SM1550-BIDI |
TX: 1550 RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
70 km (43.50 miles) |
GE SFP cable |
|||||
SFP-STACK-Kit |
N/A |
N/A |
N/A |
N/A |
1.5 m (4.92 ft) |
IMPORTANT: The SFP-GE-LX-SM1310-BIDI and SFP-GE-LX-SM1490-BIDI transceiver modules, the SFP-GE-LH40-SM1310-BIDI and SFP-GE-LH40-SM1550-BIDI transceiver modules, and the SFP-GE-LH70-SM1490-BIDI and SFP-GE-LH70-SM1550-BIDI transceiver modules must be used in pairs. For example, if one end uses the SFP-GE-LX-SM1310-BIDI transceiver module, the other end must use the SFP-GE-LX-SM1490-BIDI transceiver module. |
Table4-4 10-GE SFP+ transceiver modules available for the SFP+ ports
10-GE SFP+ module |
Central wavelength (nm) |
Connector |
Fiber diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
SFP-XG-SX-MM850-A |
850 |
LC |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multi-mode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-SX-MM850-D |
850 |
LC |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multi-mode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-SX-MM850-E |
850 |
LC |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multi-mode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-SX-MM850-S |
850 |
LC |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
500 |
82 m (269.03 ft) |
||||
400 |
66 m (216.54 ft) |
||||
Multi-mode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
160 |
26 m (85.30 ft) |
||||
SFP-XG-LX-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1310-E |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LX-SM1310-S |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-XG-LH40-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH40-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH80-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-XG-LH80-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-XG-LX-SM1270-BIDI |
TX: 1270 RX: 1330 |
LC |
Single-mode, 9/125 |
N/A |
10 m (32.81 ft) |
SFP-XG-LX-SM1330-BIDI |
TX: 1330 RX: 1270 |
LC |
Single-mode, 9/125 |
N/A |
10 m (32.81 ft) |
SFP-XG-LH40-SM1270-BIDI |
TX: 1270 RX: 1330 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH40-SM1330-BIDI |
TX: 1330 RX: 1270 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
SFP-XG-LH80-SM1490-BIDI |
TX: 1490 RX: 1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
SFP-XG-LH80-SM1550-BIDI |
TX: 1550 RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
IMPORTANT: · The SFP-XG-LX-SM1270-BIDI and SFP-XG-LX-SM1330-BIDI transceiver modules must be used in pairs. For example, if one end uses an SFP-XG-LX-SM1270-BIDI transceiver module, the other end must use an SFP-XG-LX-SM1330-BIDI transceiver module. · The SFP-XG-LH40-SM1270-BIDI and SFP-XG-LH40-SM1330-BIDI transceiver modules must be used in pairs. For example, if one end uses an SFP-XG-LH40-SM1270-BIDI transceiver module, the other end must use an SFP-XG-LH40-SM1330-BIDI transceiver module. · The SFP-XG-LH80-SM1490-BIDI and SFP-XG-LH80-SM1550-BIDI transceiver modules must be used in pairs. For example, if one end uses an SFP-XG-LH80-SM1490-BIDI transceiver module, the other end must use an SFP-XG-LH80-SM1550-BIDI transceiver module. |
Table4-5 SFP+ copper cables available for the SFP+ ports
SFP+ copper cable |
Cable length |
LSWM1STK |
0.65 m (2.13 ft) |
LSWM2STK |
1.2 m (3.94 ft) |
LSWM3STK |
3 m (9.84 ft) |
LSTM1STK |
5 m (16.40 ft) |
Table4-6 SFP+ fiber cables available for the SFP+ ports
SFP+ fiber cable |
Cable length |
SFP-XG-D-AOC-7M |
7 m (22.97 ft) |
SFP-XG-D-AOC-10M |
10 m (32.81 ft) |
SFP-XG-D-AOC-20M |
20 m (65.62 ft) |
Figure4-1 SFP+ cable
(1) SFP+ module |
(2) Pull latch |
IMPORTANT: · Ports 1 to 8 on the S6520X-54HC-EI and S6520X-54HC-HI switches do not support GE SFP transceiver modules or cables. · The SFP+ ports on the S6520X-54QC-EI and S6520X-54QC-HI switches do not support the LSTM1STK cable. |
|
NOTE: · As a best practice, use H3C transceiver modules and network cables for the switch. · The H3C transceiver modules and network cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact H3C Support or marketing staff. · For the specifications of H3C transceiver modules and network cables, see H3C Transceiver Modules User Guide. |
SFP28 port
The LSWM2ZSP8P and LSWM2ZSP2P interface modules provides SFP28 ports. To connect peer SFP28 ports over a long distance, use SFP28 transceiver modules and fibers. To connect peer SFP28 ports over a short distance, use SFP28 cables. You can install SFP28 transceiver modules in Table4-7 and SFP28 cables in Table4-8 in the SFP28 ports.
Table4-7 SFP28 transceiver modules available for the SFP28 ports
SFP28 transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
SFP-25G-LR-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
SFP-25G-SR-MM850 |
850 |
LC |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
Table4-8 SFP28 cables available for the SFP28 ports
SFP28 cable |
Max transmission distance |
SFP-25G-D-CAB-1M |
1 m (3.28 ft) |
SFP-25G-D-CAB-3M |
3 m (9.84 ft) |
SFP-25G-D-CAB-5M |
5 m (16.40 ft) |
SFP-25G-D-AOC-3M |
3 m (9.84 ft) |
SFP-25G-D-AOC-5M |
5 m (16.40 ft) |
SFP-25G-D-AOC-7M |
7 m (22.97 ft) |
SFP-25G-D-AOC-10M |
10 m (32.81 ft) |
SFP-25G-D-AOC-20M |
20 m (65.62 ft) |
Figure4-2 SFP28 cable
(1) SFP28 module |
(2) Pull latch |
|
NOTE: · As a best practice, use H3C transceiver modules and network cables for the switch. · The H3C transceiver modules and network cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact H3C Support or marketing staff. · For the specifications of H3C transceiver modules and network cables, see H3C Transceiver Modules User Guide. |
QSFP+ port
The S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30QC-HI, and S6520X-54QC-HI switches and the LSWM2QP2P interface module provide QSFP+ ports. You can install QSFP+ transceiver modules in Table4-9, QSFP+ cables in Table4-10, and QSFP+ to SFP+ cables in Table4-11 in the QSFP+ ports.
Table4-9 QSFP+ transceiver modules available for the QSFP+ ports
QSFP+ transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
QSFP-40G-SR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-CSR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
4700 |
400 m (1312.33 ft) |
||||
QSFP-40G-LR4-PSM1310 |
1310 |
MPO |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-40G-LR4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-40G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-40G-BIDI-SR-MM850 |
Two lanes: · 850. · 900. |
LC |
Multi-mode, 50/125 |
2000 |
100 m (328.08 ft) |
4700 |
150 m (492.12 ft) |
||||
QSFP-40G-BIDI-WDM850 |
Four lanes: · 850 · 880 · 910 · 940 |
LC |
Multi-mode, 50/125 |
2000 |
240 m (787.40 ft) |
4700 |
350 m (1148.29 ft) |
||||
QSFP-40G-ER4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
Table4-10 QSFP+ cables available for the QSFP+ ports
QSFP+ cable |
Max transmission distance |
LSWM1QSTK0 |
1 m (3.28 ft) |
LSWM1QSTK1 |
3 m (9.84 ft) |
LSWM1QSTK2 |
5 m (16.40 ft) |
Table4-11 QSFP+ to SFP+ cables available for the QSFP+ ports
QSFP+ to SFP+ cable |
Max transmission distance |
LSWM1QSTK3 |
1 m (3.28 ft) |
LSWM1QSTK4 |
3 m (9.84 ft) |
LSWM1QSTK5 |
5 m (16.40 ft) |
Table4-12 QSFP+ fiber cables available for the QSFP+ ports
QSFP+ to SFP+ cable |
Max transmission distance |
QSFP-40G-D-AOC-3M |
3 m (9.84 ft) |
QSFP-40G-D-AOC-7M |
7 m (22.97 ft) |
QSFP-40G-D-AOC-10M |
10 m (32.81 ft) |
QSFP-40G-D-AOC-20M |
20 m (65.62 ft) |
Figure4-3 40G QSFP+ cable
(1) QSFP+ module |
(2) Pull latch |
Figure4-4 40G QSFP+ to SFP+ cable
(1) QSFP+ module |
(2) QSFP+ module side pull latch |
(3) SFP+ module side pull latch |
(4) SFP+ module |
IMPORTANT: · You can install a QSFP-40G-LR4-PSM1310 transceiver module on an S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30QC-HI, or S6520X-54QC-HI switch, or on a QSFP+ port on an LSWM2QP2P interface module. You cannot use a QSFP-40G-LR4-PSM1310 transceiver module to connect a QSFP+ port to four SFP+ ports. · You can use a QSFP-40G-SR4-MM850 or QSFP-40G-CSR4-MM850 transceiver module to connect a QSFP+ port to four SFP+ ports. The QSFP+ transceiver module and SFP+ transceiver modules to be connected must be the same in specifications, including central wavelength and fiber type. · Only the S6520X-30HF-EI, S6520X-54HF-EI, S6520X-30HF-HI, and S6520X-54HF-HI switches support the QSFP-40G-ER4-WDM1300 transceiver modules. |
|
NOTE: · As a best practice, use H3C transceiver modules and network cables for the switch. · The H3C transceiver modules and network cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact H3C Support or marketing staff. · For the specifications of H3C transceiver modules and network cables, see H3C Transceiver Modules User Guide. |
QSFP28 port
The S6520X-30HC-EI, S6520X-54HC-EI, S6520X-30HC-HI, S6520X-54HC-HI, S6520X-30HF-EI, S6520X-54HF-EI, S6520X-30HF-HI, and S6520X-54HF-HI switches and the LSWM2ZQP2P interface module provide QSFP28 ports. You can install QSFP+ modules and cables in Table4-9, Table4-10, and Table4-11, and QSFP28 modules and cables in Table4-13 and Table4-14 in the QSFP28 ports as needed.
Table4-13 QSFP28 transceiver modules available for the QSFP28 ports
Model |
Central wavelength (nm) |
Connector |
Cable/Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
QSFP-100G-SR4-MM850 |
840 to 860 |
MPO |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
4700 |
100 m (328.08 ft) |
||||
QSFP-100G-ER4L-WDM1300 |
Four lanes: · 1295 · 1300 · 1304 · 1309 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
QSFP-100G-LR4-WDM1300-A |
Four lanes: · 1295 · 1300 · 1304 · 1309 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-100G-LR4-WDM1300 |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
QSFP-100G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
2 km (1.24 miles) |
QSFP-100G-PSM4-SM1310 |
1310 |
MPO |
Single-mode, 9/125 |
N/A |
0.5 km (0.31 miles) |
Table4-14 QSFP28 cables available for the QSFP28 ports
Model |
Max transmission distance |
QSFP-100G-D-CAB-1M |
1 m (3.28 ft) |
QSFP-100G-D-CAB-3M |
3 m (9.84 ft) |
QSFP-100G-D-CAB-5M |
5 m (16.40 ft) |
QSFP-100G-D-AOC-7M |
7 m (22.97 ft) |
QSFP-100G-D-AOC-10M |
10 m (32.81 ft) |
QSFP-100G-D-AOC-20M |
20 m (65.62 ft) |
Table4-15 QSFP28 to SFP28 cables available for the QSFP28 ports
QSFP28 fiber cable |
Max transmission distance |
QSFP-100G-4SFP-25G-CAB-1M |
1 m (3.28 ft) |
QSFP-100G-4SFP-25G-CAB-3M |
3 m (9.84 ft) |
QSFP-100G-4SFP-25G-CAB-5M |
5 m (16.40 ft) |
Figure4-5 100G QSFP28 cable
(1) QSFP28 module |
(2) Pull latch |
Figure4-6 100G QSFP28 to 4 × 25G SFP28 cable
(1) QSFP28 module |
(2) QSFP28 module side pull latch |
(3) SFP28 module |
(4) SFP28 module side pull latch |
IMPORTANT: · A QSFP-100G-SR4-MM850 transceiver module supports one-to-four splitting. You can use it to connect a 100G QSFP28 port to four 25G SFP28 ports. The QSFP28 transceiver module and SFP28 transceiver modules to be connected must be the same in specifications, including central wavelength and fiber type. · QSFP28 ports do not support QSFP+ to SFP+ cables and cannot be split to 10GE ports by using QSFP+ transceiver modules. · The S6520X-30HF-EI, S6520X-54HF-EI, S6520X-30HF-HI, and S6520X-54HF-HI switches do not support the QSFP-100G-D-CAB-5M transceiver modules. |
|
NOTE: · As a best practice, use H3C transceiver modules and network cables for the switch. · The H3C transceiver modules and network cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact H3C Support or marketing staff. · For the specifications of H3C transceiver modules and network cables, see H3C Transceiver Modules User Guide. |
10G/5G/2.5G/1000BASE-T autosensing Ethernet ports
The LSWM2XMGT8P interface module provides 10G/5G/2.5G/1000BASE-T autosensing Ethernet ports. Table4-16 describes the 10G/5G/2.5G/1000BASE-T autosensing Ethernet port specifications.
Table4-16 10G/5G/2.5G/1000BASE-T autosensing Ethernet port specifications
Item |
Specification |
Connector type |
RJ-45 |
Rate, duplex mode, and auto-MDI/MDI-X |
1/2.5/5/10 Gbps, full-duplex, auto MDI/MDI-X |
Transmission medium and max transmission distance |
· 10G mode ¡ Category 6 or above shielded twisted pair cable: 100 m (328.08 ft) ¡ Category 5e twisted pair cable or Category 6 unshielded twisted pair cable: 55 m (180.45 ft) · 5G mode: 100 m (328.08 ft) over a Category 5e or above twisted pair cable · 2.5G mode: 200 m (656.17 ft) over a Category 5e or above twisted pair cable · 1G mode: 140 m (459.32 ft) over a Category 5e or above twisted pair cable |
Standard |
IEEE 802.3ab, IEEE 802.3an, 802.3bz |
5G/2.5G/1000BASE-T autosensing Ethernet ports
The LSWM2MGT8P interface module provides 5G/2.5G/1000BASE-T autosensing Ethernet ports. Table4-16 describes the 5G/2.5G/1000BASE-T autosensing Ethernet port specifications.
Table4-17 5G/2.5G/1000BASE-T autosensing Ethernet port specifications
Item |
Specification |
Connector type |
RJ-45 |
Rate, duplex mode, and auto-MDI/MDI-X |
1/2.5/5 Gbps, full-duplex, auto MDI/MDI-X |
Transmission medium and max transmission distance |
· 5G mode: 100 m (328.08 ft) over a Category 5e or above twisted pair cable · 2.5G mode: 200 m (656.17 ft) over a Category 5e or above twisted pair cable · 1G mode: 140 m (459.32 ft) over a Category 5e or above twisted pair cable |
Standard |
IEEE 802.3ab, IEEE 802.3an, 802.3bz |
LEDs
System status LED
The system status LED shows the operating state of the switch.
Table4-18 System status LED description
LED mark |
Status |
Description |
SYS |
Steady green |
The switch is operating correctly. |
Flashing green (1 Hz) |
The switch is performing power-on self test (POST). |
|
Steady red |
The switch has failed the POST or is faulty. |
|
Off |
The switch is powered off. |
Power supply status LED
The switch provides two power supply slots on the rear panel. The S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30HC-EI, S6520X-54HC-EI, S6520X-30QC-HI, S6520X-54QC-HI, S6520X-30HC-HI, and S6520X-54HC-HI switches each provide two power status LEDs PWR1 and PWR2 on the front panel. The power status LEDs show the operating status of power supply 1 (PWR1) and power supply 2 (PWR2), respectively.
Table4-19 Power supply status LED description
LED mark |
Status |
Description |
PWR1/PWR2 |
Steady green |
A power supply is installed in the power supply slot, and the power supply is outputting power correctly. |
Steady yellow |
A power supply is installed in the power supply slot, but the power supply has failed or no power is input to the power supply. |
|
Off |
No power supply is installed in the power supply slot. |
MODE LED
To show more information about the switch through the port LEDs, the S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30HC-EI, S6520X-54HC-EI, S6520X-30QC-HI, S6520X-54QC-HI, S6520X-30HC-HI, and S6520X-54HC-HI switches each provide a MODE LED (MODE) to indicate the type of information that the port status LEDs are showing.
You can use the mode button to change the indication of the MODE LED.
Table4-20 Description for the mode LED
LED mark |
Status |
Description |
MODE |
Steady green |
The port status LEDs indicate port rates. |
Flashing yellow |
The port status LEDs indicates the IRF member ID of the switch. For example, if the LEDs for ports 1 to 5 are steady green and the other LEDs are off, the IRF member ID of the switch is 5. |
IMPORTANT: · In versions earlier than Release 6326 (not inclusive) or Release 65xx versions earlier than Release 6525 (not inclusive), the MODE LED changes in color and indication after you press the mode button and keeps that state until you press the mode button again. · In other versions, after you press the mode button, the MODE LED changes in color and indication and keeps that state for only 60 seconds and then turns steady green automatically. |
Management Ethernet port LED
Table4-21 Management Ethernet port LED description
Management Ethernet port LED (ACT/LINK) status |
Description |
Steady green |
A link is present on the port. |
Flashing yellow |
The port is sending or receiving data. |
Off |
No link is present on the port. |
SFP+ port LED
Table4-22 describes the SFP+ port LEDs on the S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30HC-EI, S6520X-54HC-EI, S6520X-30QC-HI, S6520X-54QC-HI, S6520X-30HC-HI, and S6520X-54HC-HI switches.
Table4-22 SFP+ port LED description
MODE LED status |
SFP+ port LED status |
Description |
Steady green (rate mode) |
Steady green |
A link is present on the port and the port is operating at 10 Gbps. |
Flashing green |
The port is sending or receiving data at 10 Gbps. |
|
Steady yellow |
A link is present on the port and the port is operating at 1 Gbps. |
|
Flashing yellow |
The port is sending or receiving data at 1 Gbps. |
|
Off |
· No link is present on the port. · The mode LED operates in IRF mode. |
|
Flashing yellow (IRF mode) |
Steady green |
The port status LEDs on the switch work in conjunction to indicate the IRF member ID of the switch. For example, if the LEDs for ports 1 to 5 are steady green and the other port LEDs are off, the IRF member ID of the switch is 5. |
Table4-23 describes the SFP+ port LEDs on the S6520X-30HF-EI, S6520X-54HF-EI, S6520X-30HF-HI, and S6520X-54HF-HI switches.
Table4-23 SFP+ port LED description
SFP+ port LED status |
Description |
Steady green |
A link is present on the port and the port is operating at 10 Gbps. |
Flashing green |
The port is sending or receiving data at 10 Gbps. |
Steady yellow |
A link is present on the port and the port is operating at 1 Gbps. |
Flashing yellow |
The port is sending or receiving data at 1 Gbps. |
Off |
No transceiver module or cable has been installed or no link is present on the port. |
QSFP+ port LED
The S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30QC-HI, and S6520X-54QC-HI switches each provide two QSFP+ ports. A LED is provided for each QSFP+ port to indicate its operating status.
Table4-24 QSFP+ port LED description
LED status |
Description |
Steady green |
A link is present on the port and the port is operating at 40 Gbps. |
Flashing green |
The port is sending or receiving data at 40 Gbps. |
Steady yellow |
A link is present on the port and the port is operating at 10 Gbps. |
Flashing yellow |
The port is sending or receiving data at 10 Gbps. |
Off |
· No transceiver module or cable has been installed or no link is present on the port. · The mode LED operates in IRF mode. |
QSFP28 port LED
The S6520X-30HC-EI, S6520X-54HC-EI, S6520X-30HC-HI, S6520X-54HC-HI, S6520X-30HF-EI, S6520X-54HF-EI, S6520X-30HF-HI, and S6520X-54HF-HI switches each provide QSFP28 ports. A LED is provided for each QSFP28 port to indicate its operating status.
Table4-25 QSFP28 port LED description
LED status |
Description |
Steady green |
A link is present on the port and the port is operating at 100 Gbps. |
Flashing green |
The port is sending or receiving data at 100 Gbps. |
Steady yellow |
A link is present on the port and the port is operating at 40 Gbps. |
Flashing yellow |
The port is sending or receiving data at 40 Gbps. |
Off |
· No transceiver module or cable has been installed in the port or no link is present on the port. · The mode LED is in IRF mode. (Only supported on the S6520X-30QC-EI, S6520X-54QC-EI, S6520X-30HC-EI, S6520X-54HC-EI, S6520X-30QC-HI, S6520X-54QC-HI, S6520X-30HC-HI, and S6520X-54HC-HI switches.) |
Expansion card status LED
The expansion card status LEDs SLOT1 and SLOT2 on the front panel indicate the operating state of the expansion cards in slot 1 and slot 2, respectively.
Table4-26 Expansion card status LED description
LED mark |
Status |
Description |
SLOT1/SLOT2 |
Steady green |
The expansion card is present and is operating correctly. |
Flashing yellow |
The switch does not support the card, or the card has failed. |
|
Off |
The expansion slot is empty. |
Port status LED on an expansion card
An expansion card provides a port status LED for each port. For more information about the LEDs, see the manual for the expansion card.
Input/output status LED on a power supply
The PSR250-12A and PSR250-12A1 power supplies each have a LED on the front panel to indicate the power input and output status. For more information about the LED, see the manual for the power supply.
Fan tray status LED on a fan tray
The LSWM1FANSCE, LSWM1FANSCBE, LSPM1FANSA-SN, and LSPM1FANSB-SN fan trays each have a LED to indicate the fan tray operating status.
Table4-27 LSWM1FANSCE and LSWM1FANSCBE fan tray status LED description
Status |
Description |
Steady yellow |
The fan tray is operating correctly. |
Flashing yellow |
The fan tray is faulty. |
Off |
The fan tray fails to be installed correctly or the switch is powered off. |
Table4-28 LSPM1FANSA-SN and LSPM1FANSB-SN fan tray status LED description
Status |
Description |
On |
The fan tray is faulty. |
Off |
The fan tray is operating correctly or the switch is powered off. |
5 Appendix D Cooling system
To dissipate heat timely and enhance system stability, the switch uses a high-performance cooling system. Consider the site ventilation design when you plan the installation site for the switch.
The switch uses removable fan trays. They provide airflow from the port side to the power supply side or from power supply side to the port side by using different types of fan trays. You must install all fan trays of the same model for the switch. Table5-1 describes fan trays available for the switch.
Table5-1 Fan trays available for the switches
Device model |
Fan tray |
Airflow direction |
S6520X-30QC-EI S6520X-54QC-EI S6520X-30HC-EI S6520X-54HC-EI S6520X-30QC-HI S6520X-54QC-HI S6520X-30HC-HI S6520X-54HC-HI |
LSWM1FANSCE |
From the power supply side to the port side and chassis sides |
LSWM1FANSCBE |
From the port side and chassis sides to the power supply side |
|
S6520X-30HF-EI S6520X-54HF-EI S6520X-30HF-HI S6520X-54HF-HI |
LSPM1FANSA-SN |
From the power supply side to the port side |
LSPM1FANSB-SN |
From the port side to the power supply side |
Figure5-1 Airflow direction (S6520X-54QC-EI)
Figure5-2 Airflow direction (LSPM1FANSA-SN on S6520X-30HF-EI)
Figure5-3 Airflow direction (LSPM1FANSB-SN on S6520X-30HF-EI)