02-FRU Compatibility Matrixes | 85.42 KB |
2 FRU compatibility matrixes
For more information about transceiver modules and cables available for modules, see H3C CR19000 Core Routers Modules and Transceivers Compatibility Matrixes.
MPUs
The router uses MPUs for system configuration and monitoring, including route calculation, forwarding table maintenance, and device monitoring. They can also provide high-precision clock and time synchronization.
The CR-19K-MPU-16A and CR-19K-MPU-16B MPUs are available for the router.
Do not install the CR-19K-MPU-16A and CR-19K-MPU-16B MPUs on the same router.
Fabric modules
Fabric modules switch data between interface modules.
Table2-1 describes the fabric modules available for the router.
Table2-1 Fabric modules available for the router
Fabric module model |
Quantity for each chassis |
CR-19K-SFU-16C |
2 to 6 |
Fabric module filler panels
The router comes with empty fabric module slots. For good ventilation, purchase and install filler panels in the empty fabric module slots.
Table2-2 Fabric module filler panels
Fabric module filler panel model |
Quantity for each chassis |
LSXM1BFP16A |
0 to 4 |
Interface modules
The interface modules offer line-rate forwarding. They provide different types of Ethernet fiber ports. Each port is a Layer 3 interface and supports varieties of features, including IP routing, forwarding, MPLS, security, QoS, multicasting, traffic statistics, and IPv6.
The router supports interface modules of different models.
Table2-3 describes the interface modules compatibility with fabric modules.
Table2-3 Interface modules compatibility with fabric modules
Interface module model |
CR-19K-SFU-16C |
CR-19K-LPU-CQ18 |
N + 1 (N≥ 5) |
CR-19K-LPU-CQ12 |
N + 1 (N≥ 4) |
CR-19K-LPU-CQ12B |
N + 1 (N≥ 4) |
CR-19K-LPU-CQ06B |
N + 1 (N≥ 4) |
CR-19K-LPU-CC08 |
N + 1 (N≥ 4) |
CR-19K-LPU-CC04 |
N + 1 (N≥ 4) |
CR-19K-LPU-CC04B |
N + 1 (N≥ 4) |
CR-19K-LPU-XP72 |
N + 1 (N≥ 4) |
CR-19K-LPU-XP48 |
N + 1 (N≥ 4) |
CR-19K-LPU-XP40 |
N + 1 (N≥ 4) |
CR-19K-LPU-XP20CC02 |
N + 1 (N≥ 4) |
CR-19K-LPU-8004 |
N + 1 (N≥ 4) |
CR-19K-LPU-4004 |
N + 1 (N≥ 4) |
CR-19K-LPU-2002 |
N + 1 (N≥ 2) |
CR-19K-LPU-2002B |
N + 1 (N≥ 2) |
CR-19K-LPU-SP |
N + 1 (N≥ 1) |
Interface subcards
Install interface subcards on interface modules. Table2-4 describes the interface subcard compatibility with interface modules.
Table2-4 Interface subcard compatibility with interface modules
Interface subcard model |
CR-19K-LPU-8004 |
CR-19K-LPU-4004 |
CR-19K-LPU-2002B |
CR-19K-LPU-2002 |
CR-HIC-CLGQ04F |
√ |
× |
× |
× |
CR-HIC-CQ02 |
√ |
× |
× |
× |
CR-HIC-CQ01 |
√ |
√ |
√ |
√ |
CR-HIC-CC01 |
× |
√ |
√ |
√ |
CR-HIC-QQ03 |
× |
√ |
√ |
√ |
CR-HIC-XP12B |
√ |
√ |
√ |
√ |
CR-HIC-XP12 |
√ |
√ |
√ |
√ |
CR-HIC-XP10 |
√ |
√ |
√ |
√ |
CR-HIC-GP12 |
× |
√ |
√ |
√ |
CR-HIC-PU02 |
× |
√ |
√ |
√ |
CR-HIC-PS04 |
× |
√ |
√ |
√ |
CR-HIC-PHP08 |
× |
√ |
√ |
√ |
CR-HIC-CLP04 |
× |
√ |
√ |
√ |
CR-HIC-ET16 |
× |
√ |
√ |
√ |
|
NOTE: · The mark √ indicates that the interface subcard is compatible with the interface module. · The mark × indicates that the interface subcard is incompatible with the interface module. |
Power supplies
The router supports both AC and DC power supplies.
The PSR2400-54D, PSR2400-54A, and PSR3000-54A power supplies are available for the router.
Do not install power supplies of different models on the same router.
Fan trays
Fan trays on a CR19000-16 router draw ambient air into the chassis through the air vents in the MPU and interface module panels, pull the air through the fabric module panels, and exhaust the air carrying heat through the air vents in the fan tray panel.
Table2-5 Fan tray specifications
Fan tray model |
Remarks |
FAN-120B-6-A |
· For the router to operate correctly, you must install two fan trays in redundancy. · Use high-speed fan tray LSXM116XFANH when the router uses CR-19K-LPU-CQ18 or CR-19K-LPU-CQ12B interface modules. |