Overview
Table 1 lists the universal line processing units available for the CR16000-F routers.
Table 1 Universal line processing units available for the CR16000-F routers
Model |
Description |
IM-MSUX (1 U) |
Universal line processing unit |
IM-MSUX (1.2 U) |
Universal line processing unit |
IM-MSEX-B |
Service processing unit |
IM-SP-B |
Universal expansion service processing module |
|
NOTE: For compatibility between the IM-MSUX universal line processing unit and switching fabric modules, see "Appendix B FRUs and compatibility matrixes" in H3C CR16000-F Routers Installation Guide. |
Key features
Carrier-grade NAT
Carrier-grade NAT (CGN) or large-scale NAT (LSN) allows a router installed with the universal line processing unit to share small pools of public addresses among many endpoints. The module also supports NAT44, NAT444, NAT64, Ds-Lite, ALG, BRAS collaboration, and IP source tracking.
Large number of concurrent sessions
Embedded with a powerful CPU for session management, the module supports over 10 million concurrent sessions with a session creation speed of over 100 thousand sessions per second, as well as session quantity limit on user basis.
Powerful forwarding performance
With advanced architecture and a powerful network processor, the module can perform high-speed data forwarding.
High availability
The module supports 1+1 and 1:1 redundancy for services to be transferred to the backup module if the primary module fails and transferred back to the primary module if the primary module recovers. Service transferring will be performed within 50 ms to ensure service continuity and avoid packet loss.
Specifications
The figures in this section are for illustration only.
IM-MSUX (1 U)
Front panel
Figure 2 IM-MSUX (1 U) front panel
(1) Status LED (see Table 2 for the LED description) |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) |
Power consumption |
158 W to 186 W |
Applicable system software versions |
7751 or later |
IM-MSUX (1.2 U)
Figure 3 IM-MSUX (1.2 U)
Front panel
Figure 4 IM-MSUX (1.2 U) front panel
(1) Status LED (see Table 2 for the LED description) |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
52.5 × 399 × 352 mm (2.07 × 15.71 × 13.86 in) |
Power consumption |
158 W to 186 W |
Applicable system software versions |
7751 or later |
IM-MSEX-B
The IM-MSEX-B service processing unit provides one subcard slot. You can use it without a subcard, or use it together with an IM-SP-B universal expansion service processing module for double CGN packet processing rate.
Figure 5 IM-MSEX-B
Front panel
Figure 6 IM-MSEX-B front panel
(1) Status LED (see Table 2 for the LED description) |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
52.5 × 399 × 355 mm (2.07 × 15.71 × 13.98 in) |
Power consumption |
248 W to 400 W |
Applicable system software versions |
8303 or later |
IM-SP-B
The IM-SP-B universal expansion service processing module must be installed on an IM-MSEX-B service processing unit for use. It occupies one subcard slot and does not provide ports.
Figure 7 IM-SP-B
Front panel
Figure 8 IM-SP-B front panel
(1) Status LED (see Table 2 for the LED description) |
Technical specifications
Item |
Specifications |
Dimensions (H × W × D) |
47.5 × 170 × 192 mm (1.87 × 6.69 × 7.56 in) |
Power consumption |
95 W to 130 W |
LEDs
Table 2 Status LED description
LED mark |
Status |
Description |
RUN (green) |
Steady on |
The module is faulty. |
Off |
The module is faulty or is not installed. |
|
Slow flashing (1 Hz) |
The module is operating correctly. |
|
Fast flashing |
The module is starting up. If the LED keeps fast flashing, module registration has failed. |
Environment requirements
Make sure the ambient environment meets the following requirements:
· Temperature and humidity requirements
Table 3 Temperature and humidity requirements
Item |
Specifications |
Operating temperature |
0°C to 45°C (32°F to 113°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Operating humidity |
10% RH to 95% RH, non-condensing |
Storage humidity |
5% RH to 95% RH, non-condensing |
· Dust protection requirements
Table 4 Dust concentration limits in the equipment room
Substance |
Particle diameter |
Concentration limit |
Dust particles |
≥ 0.5 µm |
≤ 1.8 × 107 particles/m3 |
· Corrosive gas protection requirements
Table 5 Corrosive gas concentration limits in the equipment room
Gas |
Average concentration (mg/m3) |
Maximum concentration (mg/m3) |
SO2 |
0.3 |
1.0 |
H2S |
0.1 |
0.5 |
Cl2 |
0.1 |
0.3 |
HCI |
0.1 |
0.5 |
HF |
0.01 |
0.03 |
NH3 |
1.0 |
3.0 |
O3 |
0.05 |
0.1 |
NOX |
0.5 |
1.0 |