H3C CR16000-F Routers Universal Line Processing Unit Datasheet-5W103

HomeSupportRoutersCR16000-F SeriesProduct LiteratureCard DatasheetsH3C CR16000-F Routers Universal Line Processing Unit Datasheet-5W103
Download Book

H3C CR16000-F Router Series

Universal Line Processing Unit Datasheet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2018 to 2022 New H3C Technologies Co., Ltd. All rights reserved.

No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd.

Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document are the property of their respective owners.

The information in this document is subject to change without notice.



Overview

Table 1 lists the universal line processing units available for the CR16000-F routers.

Table 1 Universal line processing units available for the CR16000-F routers

Model

Description

IM-MSUX (1 U)

Universal line processing unit

IM-MSUX (1.2 U)

Universal line processing unit

IM-MSEX-B

Service processing unit

IM-SP-B

Universal expansion service processing module

 

 

NOTE:

For compatibility between the IM-MSUX universal line processing unit and switching fabric modules, see "Appendix B FRUs and compatibility matrixes" in H3C CR16000-F Routers Installation Guide.

 

Key features

Carrier-grade NAT

Carrier-grade NAT (CGN) or large-scale NAT (LSN) allows a router installed with the universal line processing unit to share small pools of public addresses among many endpoints. The module also supports NAT44, NAT444, NAT64, Ds-Lite, ALG, BRAS collaboration, and IP source tracking.

Large number of concurrent sessions

Embedded with a powerful CPU for session management, the module supports over 10 million concurrent sessions with a session creation speed of over 100 thousand sessions per second, as well as session quantity limit on user basis.

Powerful forwarding performance

With advanced architecture and a powerful network processor, the module can perform high-speed data forwarding.

High availability

The module supports 1+1 and 1:1 redundancy for services to be transferred to the backup module if the primary module fails and transferred back to the primary module if the primary module recovers. Service transferring will be performed within 50 ms to ensure service continuity and avoid packet loss.

Specifications

The figures in this section are for illustration only.

IM-MSUX (1 U)

Figure 1 IM-MSUX (1 U)

 

Front panel

Figure 2 IM-MSUX (1 U) front panel

(1) Status LED (see Table 2 for the LED description)

 

Technical specifications

Item

Specifications

Dimensions (H × W × D)

40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in)

Power consumption

158 W to 186 W

Applicable system software versions

7751 or later

 

IM-MSUX (1.2 U)

Figure 3 IM-MSUX (1.2 U)

IM-MSUX_FL_1805

 

Front panel

Figure 4 IM-MSUX (1.2 U) front panel

(1) Status LED (see Table 2 for the LED description)

 

Technical specifications

Item

Specifications

Dimensions (H × W × D)

52.5 × 399 × 352 mm (2.07 × 15.71 × 13.86 in)

Power consumption

158 W to 186 W

Applicable system software versions

7751 or later

 

IM-MSEX-B

The IM-MSEX-B service processing unit provides one subcard slot. You can use it without a subcard, or use it together with an IM-SP-B universal expansion service processing module for double CGN packet processing rate.

Figure 5 IM-MSEX-B

 

Front panel

Figure 6 IM-MSEX-B front panel

(1) Status LED (see Table 2 for the LED description)

 

Technical specifications

Item

Specifications

Dimensions (H × W × D)

52.5 × 399 × 355 mm (2.07 × 15.71 × 13.98 in)

Power consumption

248 W to 400 W

Applicable system software versions

8303 or later

 

IM-SP-B

The IM-SP-B universal expansion service processing module must be installed on an IM-MSEX-B service processing unit for use. It occupies one subcard slot and does not provide ports.

Figure 7 IM-SP-B

 

Front panel

Figure 8 IM-SP-B front panel

(1) Status LED (see Table 2 for the LED description)

 

Technical specifications

Item

Specifications

Dimensions (H × W × D)

47.5 × 170 × 192 mm (1.87 × 6.69 × 7.56 in)

Power consumption

95 W to 130 W

 

LEDs

Table 2 Status LED description

LED mark

Status

Description

RUN (green)

Steady on

The module is faulty.

Off

The module is faulty or is not installed.

Slow flashing (1 Hz)

The module is operating correctly.

Fast flashing

The module is starting up. If the LED keeps fast flashing, module registration has failed.

 

Environment requirements

Make sure the ambient environment meets the following requirements:

·     Temperature and humidity requirements

Table 3 Temperature and humidity requirements

Item

Specifications

Operating temperature

0°C to 45°C (32°F to 113°F)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Operating humidity

10% RH to 95% RH, non-condensing

Storage humidity

5% RH to 95% RH, non-condensing

 

·     Dust protection requirements

Table 4 Dust concentration limits in the equipment room

Substance

Particle diameter

Concentration limit

Dust particles

≥ 0.5 µm

≤ 1.8 × 107 particles/m3

 

·     Corrosive gas protection requirements

Table 5 Corrosive gas concentration limits in the equipment room

Gas

Average concentration (mg/m3)

Maximum concentration (mg/m3)

SO2

0.3

1.0

H2S

0.1

0.5

Cl2

0.1

0.3

HCI

0.1

0.5

HF

0.01

0.03

NH3

1.0

3.0

O3

0.05

0.1

NOX

0.5

1.0

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网