13-设备管理命令
本章节下载 (822.29 KB)
目 录
1.1.8 diagnostic counters reset
1.1.9 diagnostic counters save
1.1.10 diagnostic counters upload
1.1.11 diagnostic logfiles upload
1.1.12 diagnostic keyinfo save
1.1.13 diagnostic keyinfo upload
1.1.19 display cpu-usage configuration
1.1.20 display cpu-usage history
1.1.22 display device manuinfo
1.1.23 display device manuinfo chassis-only
1.1.24 display device manuinfo fan
1.1.25 display device manuinfo power
1.1.26 display device manuinfo power-tray
1.1.28 display diagnostic-file
1.1.29 display diagnostic-information
1.1.33 display kernel memory alloc-failure
1.1.34 display kernel memory fragment free
1.1.37 display memory-threshold
1.1.38 display memory-threshold dma
1.1.39 display non-stop-routing status
1.1.42 display resource-monitor
1.1.44 display scheduler logfile
1.1.45 display scheduler reboot
1.1.46 display scheduler schedule
1.1.47 display system stable state
1.1.48 display transceiver alarm
1.1.49 display transceiver brief
1.1.50 display transceiver diagnosis
1.1.51 display transceiver interface
1.1.52 display transceiver itu-channel
1.1.53 display transceiver manuinfo
1.1.54 display transceiver optics interface
1.1.56 display version-update-record
1.1.59 hardware-failure-detection
1.1.60 hardware-failure-protection aggregation
1.1.61 hardware-failure-protection auto-down
1.1.68 memory-threshold usage resend-interval
1.1.69 monitor cpu-usage enable
1.1.70 monitor cpu-usage interval
1.1.71 monitor cpu-usage statistics-interval core
1.1.72 monitor cpu-usage threshold
1.1.73 monitor cpu-usage threshold core
1.1.74 monitor disk-usage disk
1.1.75 monitor disk-usage interval
1.1.76 monitor kernel memory fragment interval
1.1.77 monitor kernel memory fragment ratio
1.1.78 monitor resend cpu-usage
1.1.79 monitor resend cpu-usage core-interval
1.1.80 monitor resend memory-threshold
1.1.81 monitor resend memory-threshold dma
1.1.84 password-recovery enable
1.1.87 power-supply policy enable
1.1.88 power-supply policy priority
1.1.89 power-supply policy redundant
1.1.92 reset scheduler logfile
1.1.93 reset version-update-record
1.1.94 resource-monitor minor resend enable
1.1.95 resource-monitor output
1.1.96 resource-monitor resource
1.1.97 restore factory-default
1.1.101 scheduler reboot delay
card-mode命令用来配置接口卡的工作模式。
【命令】
card-mode chassis chassis-number slot slot-number subslot subslot-number mode-name
【缺省情况】
接口卡的工作模式为100GE模式。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
slot slot-number:表示单板所在的槽位号。
chassis chassis-number slot slot-number:指定成员设备上指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
subslot subslot-number:子卡所在的子槽位号。
mode-name:指定接口卡的工作模式。工作模式如下所示:
· 50ge:配置接口卡的工作模式为50GE模式。配置后,该接口卡上的所有接口可作为50GE接口使用。
· hge:配置接口卡的工作模式为100GE模式。配置后,该接口卡上的所有接口可作为100GE接口使用。
【使用指导】
仅缺省MDC支持本命令。
模式切换后必须重启接口卡,新配置的模式才会生效。
CR-HIC-CLGQ04F的接口1和接口3可以配置为100GE模式,接口1~4可以配置为50GE模式。当接口1和接口3配置为100GE模式时,接口2和接口4禁止使用。
【举例】
# 将位于指定接口卡的工作模式配置为50GE模式。
<Sysname> system-view
[Sysname] card-mode chassis 1 slot 2 subslot 2 50ge
Please reboot or hot-swap the board or card (if supported) to make the configuration take effect.
clock datetime命令用来配置设备的系统时间。
【命令】
clock datetime time date
【缺省情况】
设备的系统时间为UTC时间2011年1月1日零点。
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
time:配置的时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将time参数配置为0表示零点。
date:配置的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。
【使用指导】
执行本命令会修改设备的系统时间,会影响和系统时间相关特性的执行(例如定时执行任务功能),以及和其他设备的协同操作(例如日志上报和统计),请谨慎执行。
仅缺省MDC支持本命令。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。
请先配置clock protocol none命令,再执行本命令。clock datetime命令中指定的时间会立即生效,作为当前的系统时间。后续,设备使用内部晶体震荡器产生的时钟信号计时。
修改夏令时或时区后,设备会自动重新计算当前的系统时间,计算后得到的系统时间可通过display clock命令查看。
【举例】
# 配置设备的系统时间为2012年1月1日8时8分8秒。
<Sysname> clock datetime 8:8:8 1/1/2012
# 配置设备的系统时间为2012年1月1日8时10分。
<Sysname> clock datetime 8:10 2012/1/1
【相关命令】
· clock protocol
· clock summer-time
· clock timezone
· display clock
clock protocol命令用来配置系统时间的获取方式。
undo clock protocol命令用来恢复缺省情况。
【命令】
clock protocol { none | { ntp | ptp } mdc mdc-id }
undo clock protocol
【缺省情况】
从缺省MDC通过NTP协议获取时间。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
none:表示通过命令行配置系统时间。
ptp:表示通过PTP(Precision Time Protocol,精确时间协议)协议获取时间。关于PTP的详细介绍和配置,请参见“网络管理和监控配置指导”中的“PTP”。
ntp:表示通过NTP(Network Time Protocol,网络时间协议)协议获取时间。关于NTP的详细介绍和配置,请参见“网络管理和监控配置指导”中的“NTP”。
mdc mdc-id:表示时钟的来源MDC编号取值范围为1~8。
【使用指导】
仅缺省MDC支持本命令。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。
系统时间的获取方式有:
· 配置clock protocol none命令后,通过clock datetime命令直接配置。clock datetime命令中指定的时间即为当前的系统时间。后续,设备使用内部晶体震荡器产生的时钟信号计时。
· 配置clock protocol { ntp | ptp }命令后,通过NTP/PTP协议从网络中获取时间。该方式下,设备会周期性的同步服务器的UTC(Coordinated Universal Time,国际协调时间)时间,并用同步得到的UTC时间和设备上配置的本地时区、夏令时参数运算,得出当前的系统时间。该方式获取的时间比命令行配置的时间更精准,推荐使用。
多次执行本命令,最后一次执行的命令生效。
修改夏令时或时区后,设备会自动重新计算当前的系统时间,计算后得到的系统时间可通过display clock命令查看。
所有MDC的系统时间相同。当设备从某个MDC获取时钟后,会同步给其它MDC。
【举例】
# 配置获取UTC时间的方式为通过命令行配置。
<Sysname> system-view
[Sysname] clock protocol none
clock summer-time命令用来配置夏令时。
undo clock summer-time命令用来恢复缺省情况。
【命令】
clock summer-time name start-time start-date end-time end-date add-time
undo clock summer-time
【缺省情况】
未配置夏令时。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
name:夏令时的名称,为1~32个字符的字符串,区分大小写。
start-time:开始时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。
start-date:开始日期,有两种输入方式:
· 直接一次性输入月和日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关。
· 分次输入月、日,各参数之间以<空格>键隔开。首先输入开始的月份,取值如下:January、February、March、April、May、June、July、August、September、October、November或December;然后输入开始的星期,用当月的第几个星期表示,取值如下:first、second、third、fourth、fifth或last;最后输入起始日,取值为Sunday、Monday、Tuesday、Wednesday、Thursday、Friday或Saturday。
end-time:结束时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。
end-date:结束日期,有两种输入方式:
· 直接一次性输入月日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关。
· 分次输入月、日,各参数之间以<空格>键隔开。首先输入开始的月份,取值如下:January、February、March、April、May、June、July、August、September、October、November或December;然后输入开始的星期,用当月的第几个星期表示,取值如下:first、second、third、fourth、fifth或last;最后输入起始日,取值为Sunday、Monday、Tuesday、Wednesday、Thursday、Friday或Saturday。
add-time:偏移时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。
【使用指导】
仅缺省MDC支持本命令。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。
配置该命令后,设备会自动重新计算当前的系统时间,计算后得到的系统时间可通过display clock命令查看。
请将所有网络设备的夏令时和当地夏令时保持一致。
【举例】
# 配置夏令时PDT,从每年的8月1日的06:00:00开始,到9月1日的06:00:00结束,比当前设备标准时间增加1小时。
<Sysname> system-view
[Sysname] clock summer-time PDT 6 08/01 6 09/01 1
【相关命令】
· clock datetime
· clock timezone
· display clock
clock timezone命令用来配置系统所在的时区。
undo clock timezone命令用来恢复缺省情况。
【命令】
clock timezone zone-name { add | minus } zone-offset
undo clock timezone
【缺省情况】
系统所在的时区为零时区,即设备采用格林威治标准时间。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
zone-name:时区名称,为1~32个字符的字符串,区分大小写。
add:在UTC时间的基础上增加指定时间。
minus:在UTC时间的基础上减少指定时间。
zone-offset:与UTC的时间差,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59,如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。
【使用指导】
仅缺省MDC支持本命令。
为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的。
配置该命令后,设备会自动重新计算当前的系统时间,计算后得到的系统时间可通过display clock命令查看。
请将所有网络设备的时区和当地地理时区保持一致。
【举例】
# 配置本地时区名称为Z5,比UTC标准时间增加5小时。
<Sysname> system-view
[Sysname] clock timezone Z5 add 5
【相关命令】
· clock datetime
· clock summer-time
· display clock
command命令用来为Job分配命令。
undo command命令用来取消为Job分配的命令。
【命令】
command id command
undo command id
【缺省情况】
没有为Job分配命令。
【视图】
Job视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
id:命令编号,取值范围为0~4294967295。该编号表示命令在Job中的执行顺序,编号小的命令优先执行。
command:为Job分配的命令。
【使用指导】
多次输入command命令可以为当前Job分配多条命令,不同命令用编号来唯一区别。如果新分配命令的编号和已分配的某命令的编号相同,则新分配的命令会覆盖已分配的命令。
通过command分配的命令行必须是设备上可成功执行的命令行,不包括telnet、ftp、ssh2和monitor process。由用户保证配置的正确性,否则,命令行不能自动被执行。
如果需要分配的命令(假设为A)是用户视图下的命令,则直接使用command命令分配即可,比如:command 1 display interface;如果需要分配的命令(假设为A)是非用户视图下的命令,则必须先分配进入A所在视图的命令(指定较小的id值),再分配A。比如:要使用Job定时执行shutdown命令,则需执行三次command命令,分别分配system-view、interface、shutdown命令,且各command命令的id值逐渐增大。
定时执行任务时,设备不会与用户交互信息。当需要用户交互确认时,系统将自动输入“Y”或“Yes”;当需要用户交互输入字符信息时,系统将自动输入缺省字符串,没有缺省字符串的将自动输入空字符串。
【举例】
# 为名称为backupconfig的Job分配命令,以便将配置文件startup.cfg备份到TFTP服务器192.168.100.11。
<Sysname> system-view
[Sysname] scheduler job backupconfig
[Sysname-job-backupconfig] command 2 tftp 192.168.100.11 put flash:/startup.cfg backup.cfg
# 为Job(假设名称为shutdownGE)分配命令,以便将接口GigabitEthernet1/2/0/1关闭。
<Sysname> system-view
[Sysname] scheduler job shutdownGE
[Sysname-job-shutdownGE] command 1 system-view
[Sysname-job-shutdownGE] command 2 interface gigabitethernet 1/2/0/1
[Sysname-job-shutdownGE] command 3 shutdown
【相关命令】
· scheduler job
copyright-info enable命令用来开启版权信息显示功能。
undo copyright-info enable命令用来关闭版权信息显示功能。
【命令】
copyright-info enable
undo copyright-info enable
【缺省情况】
版权信息显示功能处于开启状态。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【举例】
# 开启版权信息显示功能。
<Sysname> system-view
[Sysname] copyright-info enable
重新登录设备后,会显示如下信息:
******************************************************************************
* Copyright (c) 2004-2017 New H3C Technologies Co., Ltd. All rights reserved.*
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
******************************************************************************
diagnostic counters reset命令用来清除保存在本地的设备或单板的统计信息。
【命令】
diagnostic counters [ chassis chassis-number [ slot slot-number ] ] reset
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:清除集群系统中指定成员设备保存在本地存储介质中的统计信息。chassis-number表示成员设备编号,未指定该参数时表示集群系统中的所有成员设备。
slot slot-number:清除指定单板保存在本地存储介质的统计信息。slot-number表示单板槽位号。未指定该参数时表示设备上的所有单板。
【举例】
# 配置清除指定单板保存在本地的统计信息。
<Sysname>diagnostic counters chassis 1 slot 2 reset
Parallel execution of this command causes errors. Please make sure this command is not being executed by other users. Continue? [Y/N]:y
Processing, please wait...Elapsed 0:0:9
【相关命令】
· diagnostic counters save
diagnostic counters save命令用来收集设备或单板的统计信息,并以压缩包的形式保存到本地存储介质。
【命令】
diagnostic counters [ chassis chassis-number [ slot slot-number ] ] save filename
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:收集集群系统中指定成员设备的统计信息,并保存到本地存储介质。chassis-number表示成员设备编号,未指定该参数时表示集群系统中的所有成员设备。
slot slot-number:收集指定单板的统计信息并保存到本地存储介质。slot-number表示单板槽位号,未指定该参数时表示设备上的所有单板。
filename:为统计信息的压缩包文件命名。最多可以输入31个字符,区分大小写。
【举例】
# 配置收集指定单板的统计信息,将压缩包文件命名为abc并保存到本地。
<Sysname>diagnostic counters chassis 1 slot 2 save abc
Parallel execution of this command causes errors. Please make sure this command is not being executed by other users. Continue? [Y/N]:y
Processing, please wait...Elapsed 0:0:9
【相关命令】
· diagnostic counters reset
· diagnostic counters upload
diagnostic counters upload命令用来收集设备或单板的统计信息,并以压缩包的形式上传到服务器。
【命令】
diagnostic counters [ chassis chassis-number [ slot slot-number ] ] upload { tftp server-ip | ftp server-ip username } [ vpn-instance vpn-instance-name ] filename
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:收集集群系统中指定成员设备的统计信息,并上传到服务器。chassis-number表示成员设备编号,未指定该参数时表示集群系统中的所有成员设备。
slot slot-number:收集指定单板的统计信息并上传到服务器。slot-number表示单板槽位号,未指定该参数时表示设备上的所有单板。
tftp server-ip:表示采用TFTP方式上传。server-ip为TFTP服务器IP地址。
ftp server-ip username:表示采用FTP方式上传。server-ip为FTP服务器IP地址。username为登录服务器所用的用户名。
vpn-instance vpn-instance-name:VPN实例名称,为1~31个字符的字符串,区分大小写。
filename:为统计信息的压缩包文件命名。最多可以输入31个字符,区分大小写。
【举例】
# 配置收集指定单板的统计信息,将压缩包文件命名为abc并上传到服务器。
<Sysname>diagnostic counters chassis 1 slot 2 upload tftp 1.1.1.1 abc
Parallel execution of this command causes errors. Please make sure this command is not being executed by other users. Continue? [Y/N]:y
Processing, please wait...Elapsed 0:0:9
【相关命令】
· diagnostic counters save
· diagnostic counters reset
diagnostic logfiles upload命令用来收集日志信息,并以压缩包的形式上传到服务器。
【命令】
diagnostic logfiles upload { ftp server-ip username | tftp server-ip } [ vpn-instance vpn-instance-name ] filename
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
ftp server-ip username:表示采用FTP方式上传。server-ip为FTP服务器IP地址,username为登录服务器时的用户名。
tftp server-ip:表示采用TFTP方式上传。server-ip为TFTP服务器IP地址。
vpn-instance vpn-instance-name:VPN实例名称,为1~31个字符的字符串,区分大小写。
filename:为关键维护信息的压缩包文件命名。最多可以输入31个字符,区分大小写。
【举例】
# 收集日志信息并以FTP方式上传到服务器。FTP服务器IP地址为172.31.116.1,登录用户名为admin,压缩包文件命名为abc。
<Sysname> diagnostic logfiles upload ftp 172.31.116.1 admin abc
Parallel execution of this command causes errors. Please make sure this command is not being executed by other users. Continue? [Y/N]:y
FTP password:
Collecting logs...Please wait. Elapsed time: 0:0:16
% Total % Received % Xferd Average Speed Time Time Time Current
Dload Upload Total Spent Left Speed
100 7566k 100 0 100 7566k 0 10.4M --:--:-- --:--:-- --:--:-- 10.5M
表1-1 diagnostic logfiles upload命令显示信息描述表
字段 |
描述 |
% Total |
%为文件传输的进度百分比。Total为要传输的文件大小,单位为字节 |
% Received |
%为下载时已接收文件大小占文件总大小的百分比。Received为下载时已接收的文件大小,单位为字节 |
% Xferd |
%为上传时已发送文件大小与文件总大小的百分比,Xferd为上传时已发送的文件大小,单位为字节 |
Average Dload |
平均下载速度,单位为字节/秒 |
Speed Upload |
平均上传速度,单位为字节/秒 |
Time Total |
文件传输时已花费时间和剩余时间的总和,单位为秒 |
Time Spent |
文件传输时已花费时间,单位为秒 |
Time Left |
完成文件传输,还需要的时间,单位为秒 |
Current Speed |
文件传输时的当前速度,单位为字节/秒 |
diagnostic keyinfo save命令用来收集设备或单板的关键维护信息,并以压缩包的形式保存到本地存储介质。
【命令】
diagnostic keyinfo [ chassis chassis-number [ slot slot-number ] ] save filename
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:收集集群系统中指定成员设备的关键维护信息,并保存到本地存储介质。chassis-number表示成员设备编号,未指定该参数时表示集群系统中的所有成员设备。
slot slot-number:收集指定单板的关键维护信息并保存到本地存储介质。slot-number表示单板槽位号,未指定该参数时表示设备上的所有单板。
filename:为关键维护信息的压缩包文件命名。最多可以输入31个字符,区分大小写。
【举例】
# 配置收集指定单板的关键维护信息,将压缩包文件命名为abc并保存到本地。
<Sysname>diagnostic keyinfo chassis 1 slot 2 save abc
Parallel execution of this command causes errors. Please make sure this command is not being executed by other users. Continue? [Y/N]:y
Processing, please wait...Elapsed 0:0:9
【相关命令】
· diagnostic keyinfo upload
diagnostic keyinfo upload命令用来收集设备或单板的关键维护信息,并以压缩包的形式上传到服务器。
【命令】
diagnostic keyinfo [ chassis chassis-number [ slot slot-number ] ] upload { tftp server-ip | ftp server-ip username } [ vpn-instance vpn-instance-name ] filename
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:收集集群系统中指定成员设备的关键维护信息,并上传到服务器。chassis-number表示成员设备编号,未指定该参数时表示集群系统中的所有成员设备。
slot slot-number:收集指定单板的关键维护信息并上传到服务器。slot-number表示单板槽位号,未指定该参数时表示设备上的所有单板。
tftp server-ip:表示采用TFTP方式上传。server-ip为TFTP服务器IP地址。
ftp server-ip username:表示采用FTP方式上传。server-ip为FTP服务器IP地址,username为登录服务器时的用户名。
vpn-instance vpn-instance-name:VPN实例名称,为1~31个字符的字符串,区分大小写。
filename:为关键维护信息的压缩包文件命名。最多可以输入31个字符,区分大小写。
【举例】
# 配置收集指定单板的关键维护信息,将压缩包文件命名为abc并上传到服务器。
<Sysname>diagnostic keyinfo chassis 1 slot 2 upload tftp 1.1.1.1 abc
Parallel execution of this command causes errors. Please make sure this command is not being executed by other users. Continue? [Y/N]:y
Processing, please wait...Elapsed 0:0:9
【相关命令】
· diagnostic keyinfo save
display alarm active命令用来显示设备当前仍未恢复的告警信息。
【命令】
display alarm active [ verbose ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
verbose:显示告警项的详细信息。不指定该参数时,显示告警项的概要信息。
【使用指导】
仅缺省MDC支持本命令。
当设备的电源、CPU、风扇等运行异常时,使用display alarm命令可以查看到相应的告警信息。对于过去发生的、已经恢复的告警可以使用display alarm history命令查看;对于过去发生的、当前仍未恢复的告警可以使用display alarm active命令查看。
【举例】
# 显示设备当前仍未恢复的告警信息。
<Sysname> display alarm active
Seq Level Time Info
24 Warning 2020-01-11 12:40:00 CPU usage is in minor alarm state on chassis 1 slot 1.
23 Warning 2020-01-11 12:30:00 Memory minor threshold has been exceeded on chassis 1 slot 1.
22 Minor 2020-01-11 12:18:00 Board state changed to Fault on chassis 1 slot 1.
表1-2 display alarm active命令显示信息描述表
字段 |
描述 |
Seq |
告警序列号,告警发生时分配。 |
Level |
告警的级别,级别由高到低依次为Critical、Major、Minor、Warning |
Time |
告警产生的时间 |
Info |
告警的详细信息,涉及风扇、电源、设备温度等硬件故障,主要取值包括: · Board state changed to Fault on chassis xx slot xx:框xx槽位xx上的单板变成Fault状态(该单板可能正在启动,或者处于故障状态) · Chassis xx slot xx fan xx is absent:框xx槽位xx上的风扇xx未插入 · Chassis xx slot xx fan xx is failed:框xx槽位xx上的风扇xx处于异常状态 · Chassis xx slot xx power xx is absent:框xx槽位xx上的电源xx未插入 · Chassis xx slot xx power xx failed:框xx槽位xx上的电源xx处于异常状态 · Temperature is higher than the high-temperature alarming threshold on chassis xx slot xx sensor inflow xx:框xx槽位xx上的传感器xx的温度高于高温门限 · Memory minor threshold has been exceeded on chassis xx slot xx:框xx槽位xx的空闲内存高于minor门限 · CPU usage is in minor alarm state on chassis xx slot xx:框xx槽位xx的CPU使用率高于minor门限 · Interface-name: RX power is high!:接口Interface-name光功率过高 · Interface-name:The bit error ratio exceeds the upper threshold:接口Interface-name误码率超过了上限 · SSH user username (IP: IP-Address) connected to the server successfully:SSH用户的用户名(IP:IP地址)成功登录服务器 · Member port xx of aggregation group xx changed to the inactive state, because xx.:聚合xx内成员接口xx因为xx原因非选中 · The mpls ldp session status changes. (SessionState=$1, DiscontinuityTime=$2, StatsUnknownMesTypeErrors=$3, StatsUnknownTlvErrors=$4):LDP会话状态变化 ¡ $1:LDP会话状态,取值包括:nonexistent,initialized,openrec,opensent,operational ¡ $2:LDP会话处于Operational状态的持续时间 ¡ $3:LDP会话收到未知信息的次数 ¡ $4:LDP会话收到未知TLV的次数 |
# 显示设备当前仍未恢复的告警信息详细内容。
<Sysname> display alarm active verbose
Seq 13
Alarm name: IPC_PKT_LOSS
Alarm source: e0003-0/ffff/0
Level: Major
Start time: 2022-05-25 19:22:40
Info: Chassis 1 slot 8: Packet loss occurred on inter-board IPC channel. Sourc
e port = Chassis 1 Slot 2, Destination port = Chassis 1 Slot 8. Detailed informa
tion = BLOCKED.
表1-3 display alarm active verbose命令显示信息描述表
字段 |
描述 |
Seq |
告警序列号,告警发生时由系统自动分配 |
Alarm name |
告警的名称 |
Alarm source |
告警对象所在位置 |
Level |
告警的级别,级别由高到低依次为Critical、Major、Minor、Warning |
Start time |
告警发生时间 |
Info |
告警的详细信息 |
【相关命令】
· display alarm history
display alarm history命令用来显示已经恢复的告警信息。
【命令】
display alarm history [ verbose ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
verbose:显示告警项的详细信息。不指定该参数时,显示概要信息。
【使用指导】
仅缺省MDC支持本命令。
对于过去发生的、已经恢复的告警可以使用display alarm history命令查看;对于过去发生的、当前仍未恢复的告警可以使用display alarm active命令查看。
本命令最多可显示的信息条数为12。
【举例】
# 显示设备告警历史信息。
<Sysname> display alarm history
Seq Time Info
23 2020-01-11 12:40:00 CPU usage recovered to normal state on chassis 1 slot 1.
本命令显示信息描述表请参见表1-2。
# 显示设备告警历史信息详细内容。
<Sysname> display alarm history verbose
Seq 23
Alarm name: CPUUsageMinor
Alarm position: chassis 1 slot 1
Start time: 2020-01-11 12:30:00
Level: Warning
Info: CPU usage is in minor alarm state on chassis 1 slot 1
Recovery time: 2020-01-11 12:40:30
Info: CPU usage minor alarm removed on chassis 1 slot 1.
表1-4 display alarm history verbose命令显示信息描述表
字段 |
描述 |
Seq |
告警序列号,告警发生时由系统自动分配 |
Alarm name |
告警的名称 |
Alarm position |
告警对象所在位置 |
Start time |
告警发生时间 |
Level |
告警的级别,级别由高到低依次为Critical、Major、Minor、Warning |
Recovery time |
告警恢复时间 |
Info |
告警的详细信息 |
【相关命令】
display clock命令用来显示系统当前的时间、日期、本地时区以及夏令时配置。
【命令】
display clock
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【举例】
# 未配置本地时区时,显示系统当前日期和时间。
<Sysname> display clock
10:09:00 UTC Fri 03/16/2015
# 配置了本地时区Z5后,显示系统当前日期和时间。
<Sysname> display clock
15:10:00 Z5 Fri 03/16/2015
Time Zone : Z5 add 05:00:00
# 配置了本地时区Z5和夏令时PDT后,显示系统当前日期和时间。
<Sysname> display clock
15:11:00 Z5 Fri 03/16/2015
Time Zone : Z5 add 05:00:00
Summer Time : PDT 06:00:00 08/01 06:00:00 09/01 01:00:00
【相关命令】
· clock datetime
· clock timezone
· clock summer-time
display copyright命令用来显示设备的版权信息。
【命令】
display copyright
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【举例】
# 显示设备的版权信息。
<Sysname> display copyright
显示信息略……。
display cpu-usage命令用来显示CPU利用率的统计信息。
【命令】
display cpu-usage [ summary ] [ chassis chassis-number slot slot-number [ cpu cpu-number [ core { core-number | all } ] ] ]
display cpu-usage [ control-plane | data-plane ] [ summary ] [ chassis chassis-number slot slot-number [ cpu cpu-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
control-plane:显示控制平面CPU利用率的统计信息。
data-plane:显示数据平面CPU利用率的统计信息。
summary:以列表形式显示CPU利用率的统计信息。不指定该参数时,以区段形式显示CPU利用率的统计信息。
chassis chassis-number slot slot-number:显示指定成员设备指定单板的CPU利用率的统计信息。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示集群中的所有单板。
cpu cpu-number:显示指定CPU的利用率统计信息。cpu-number表示CPU的编号。
core { core-number | all }:显示CPU核利用率的统计信息。其中,all表示显示所有CPU核利用率的统计信息;core-number表示CPU核的编号,显示指定CPU核利用率的统计信息。
【使用指导】
登录MDC后执行该命令,会显示该MDC可使用的CPU的利用率统计信息。
当最近5秒、最近1分钟、最近5分钟的CPU利用率取值均显示为“--”时,可能原因为命令行从设备内部数据库获取数据失败,请稍候重试。
【举例】
# 以段的形式显示当前CPU利用率统计信息。
<Sysname> display cpu-usage
Chassis 1 Slot 8 CPU 0 CPU usage:
1% in last 5 seconds
1% in last 1 minute
1% in last 5 minutes
# 以表的形式显示当前CPU利用率统计信息。
<Sysname> display cpu-usage summary
Chassis Slot CPU Last 5 sec Last 1 min Last 5 min
1 8 0 0% 1% 1%
表1-5 display cpu-usage命令显示信息描述表
字段 |
描述 |
1% in last 5 seconds |
设备启动后,会以5秒为周期计算并记录一次该5秒内的CPU的平均利用率。该字段显示的是最近一个5秒统计周期内CPU的平均利用率 |
Last 5 sec |
设备启动后,会以5秒为周期计算并记录一次该5秒内的CPU的平均利用率。该字段显示的是最近一个5秒统计周期内CPU的平均利用率 |
1% in last 1 minute |
设备启动后,会以1分钟为周期计算并记录一次该1分钟内的CPU的平均利用率。该字段显示的是最近一个1分钟统计周期内CPU的平均利用率 |
Last 1 min |
设备启动后,会以1分钟为周期计算并记录一次该1分钟内的CPU的平均利用率。该字段显示的是最近一个1分钟统计周期内CPU的平均利用率 |
1% in last 5 minutes |
设备启动后,会以5分钟为周期计算并记录一次该5分钟内的CPU的平均利用率。该字段显示的是最近一个5分钟统计周期内CPU的平均利用率 |
Last 5 min |
设备启动后,会以5分钟为周期计算并记录一次该5分钟内的CPU的平均利用率。该字段显示的是最近一个5分钟统计周期内CPU的平均利用率 |
display cpu-usage configuration命令用来显示CPU利用率监控功能的相关配置。
【命令】
display cpu-usage configuration [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。不指定该参数时,显示的是全局主用主控板上的相应信息。
cpu cpu-number:表示CPU的编号。
【使用指导】
登录MDC后执行该命令,会显示该MDC可使用的CPU的对应信息。
【举例】
# 显示CPU利用率监控功能的相关配置。
<Sysname> display cpu-usage configuration
CPU usage monitor is enabled.
Current monitor interval is 60 seconds.
Current severe alarm threshold is 90%.
Current minor alarm threshold is 80%.
表1-6 display cpu-usage configuration命令显示信息描述表
字段 |
描述 |
CPU usage monitor is enabled. |
CPU利用率历史记录功能处于开启状态 |
Current monitor interval is 60 seconds. |
CPU利用率历史记录的采样周期为60秒 |
Current severe alarm threshold is 90%. |
CPU利用率的高级别告警门限为90% |
Current minor alarm threshold is 80%. |
CPU低级别告警门限为80% |
【相关命令】
· monitor cpu-usage enable
· monitor cpu-usage interval
· monitor cpu-usage threshold
display cpu-usage history命令用来以图表方式显示CPU利用率的历史信息。
【命令】
display cpu-usage history [ job job-id ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
job job-id:显示指定进程的CPU利用率的历史信息。job-id表示进程的编号,取值范围为1~2147483647。不指定该参数时,显示的是整个系统的相应信息(整个系统的CPU利用率等于所有进程CPU利用率之和)。可以使用display process命令可以查看当前运行的进程的编号和名称,display process命令的详细介绍请参见“网络管理与监控”中的“系统维护与调试”。
chassis chassis-number slot slot-number:显示指定成员设备上指定单板的CPU利用率的历史信息。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。当不指定job和该参数时,显示的是所有单板上所有进程的相应信息;当指定job参数,但不指定该参数时,显示的是全局主用主控板上指定进程的相应信息。
cpu cpu-number:显示指定CPU的利用率的历史信息。cpu-number表示CPU的编号。当不指定job和该参数时,表示所有CPU。当指定job参数,但不指定该参数时,表示默认CPU。
【使用指导】
开启CPU利用率历史记录功能后,系统每隔一定时间(可通过monitor cpu-usage interval命令配置)会对CPU的利用率进行采样,并把采样结果保存到历史记录区。通过display cpu-usage history命令可以查看到最近60个采样点的值。结果以坐标的形式进行显示,显示信息中:
· 纵坐标表示利用率,采用就近显示的原则。比如,利用率的间隔为5%,则实际统计值53%将被显示成55%,实际统计值52%将被显示成50%。
· 横坐标表示时间,时间越靠左表示距离当前时间越近。
· 用连续的#号表示该时刻的利用率,某个时间点上最高处的#号对应的纵坐标值即为该时刻CPU的利用率。
登录MDC后执行该命令,会显示该MDC可使用的CPU的对应信息。
【举例】
# 以图表方式显示CPU利用率的历史记录。
<Sysname> display cpu-usage history
100%|
95%|
90%|
85%|
80%|
75%|
70%|
65%|
60%|
55%|
50%|
45%|
40%|
35%|
30%|
25%|
20%|
15%| #
10%| ### #
5%| ########
------------------------------------------------------------
10 20 30 40 50 60 (minutes)
cpu-usage (Chassis 1 slot 1 CPU 0) last 60 minutes (SYSTEM)
以上显示信息表明系统(用“SYSTEM”表示,运行在Chassis 1 slot 1 CPU 0上)在最近60分钟内CPU的利用率情况:12分钟前大约为5%,13分钟前大约为10%,14分钟前大约为15%,15分钟前大约为10%,16、17分钟前大约为5%,18分钟前大约为10%,19分钟前大约为5%,其它时间均小于或等于2%。
【相关命令】
· monitor cpu-usage enable
· monitor cpu-usage interval
display device命令用来显示设备信息。
【命令】
display device [ flash | harddisk | usb ] [ chassis chassis-number [ slot slot-number [ subslot subslot-number ] ] | verbose ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
flash:显示Flash的信息。
harddisk:显示硬盘的信息。
usb:显示USB接口的信息。
chassis chassis-number:显示指定成员设备的详细信息。chassis-number表示设备在集群中的成员编号。不指定该参数时,表示所有成员设备。
slot slot-number:显示指定单板的信息。slot-number表示单板所在的槽位号。不指定该参数时,表示所有单板。
subslot subslot-number:显示指定子卡的信息。subslot-number表示子卡所在的子槽位号。不指定该参数时,不会显示子卡的信息。
verbose:显示设备的详细信息。不指定该参数时,显示设备的简要信息,且此时不会显示防火墙插卡的信息。
【使用指导】
不指定flash、harddisk和usb参数时,显示单板的信息。
【举例】
# 显示设备详细信息。
<Sysname> display device verbose
Slot No. Board type Status Primary SubSlots
---------------------------------------------------------------------
1/0 N/A Absent N/A N/A
1/1 N/A Absent N/A N/A
1/2 CR-19K-LPU-CC08 Normal N/A 0
1/3 CR-19K-LPU-4004 Normal N/A 4
1/4 N/A Absent N/A N/A
1/5 N/A Absent N/A N/A
1/6 N/A Absent N/A N/A
1/7 N/A Absent N/A N/A
1/8 CR-19K-MPU-08A Normal Master 0
1/9 CR-19K-MPU-08A Startup Standby 0
1/10 CR-19K-SFU-08C Normal N/A 0
1/11 N/A Absent N/A N/A
1/12 N/A Absent N/A N/A
1/13 N/A Absent N/A N/A
1/14 N/A Absent N/A N/A
1/15 N/A Absent N/A N/A
+: Next Master
*: Local Master
Slot 1/3: CR-19K-LPU-4004
Subslot 2 : CR-HIC-CC01
表1-7 display device verbose命令显示信息描述表
字段 |
描述 |
Slot No. |
成员设备的编号/成员设备上单板所在的槽位号 |
Board type |
单板的硬件类型 |
Status |
单板状态 · Absent:表示该槽位没有插入单板 · Startup:表示该板为启动状态 · Normal:表示该板处于正常工作状态 · Fault:表示该槽位单板出错,不能正常启动 · Disable:表示单板被手工下电(执行命令power-supply off) · Wait:表示单板等待上电中 |
Primary |
单板角色: · Standby表示该板是备用主控板 · Master表示该板是主用主控板 |
SubSlots |
单板支持子卡的最大个数 |
+: Next Master |
全局备用主控板下一个主控状态 |
*: Local Master |
本地主用主控板当前主控状态 |
Subslot 2 |
子卡槽位及状态 · 子卡型号(Disable):表示该子卡未上电 · 子卡型号(Fault):表示该子卡出错,不能正常启动 · 子卡型号:表示该子卡处于正常工作状态 · Unknown:表示该子卡无法识别 |
display device manuinfo命令用来显示设备的电子标签信息。
【命令】
display device manuinfo [ chassis chassis-number [ slot slot-number [ subslot subslot-number ] ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:显示指定成员设备的电子标签信息。chassis-number表示设备在集群中的成员编号。不输入该参数时,显示所有成员设备的相应信息。
slot slot-number:显示指定单板的电子标签信息。slot-number表示单板所在的槽位号。不输入该参数时,显示所有单板的相应信息。
subslot subslot-number:显示指定子卡的电子标签信息。subslot-number表示子卡所在的子槽位号。不指定该参数时,不会显示子卡的信息。
【使用指导】
电子标签信息也可以称为永久配置数据或档案信息等,在硬件的调测(调试、测试)过程中被写入到设备的存储器件中,包括硬件的名称、生产序列号、MAC地址、制造商等信息。
【举例】
# 显示设备的电子标签信息。
<Sysname> display device manuinfo chassis 1 slot 8
Chassis 1:
Slot 8 CPU 0:
DEVICE_NAME : LSXM1SUP08C0
DEVICE_SERIAL_NUMBER : 210231A5WFH172000079
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2017-03-04
VENDOR_NAME : H3C
表1-8 display device manuinfo命令信息显示描述表
字段 |
描述 |
DEVICE_NAME |
设备名称 |
DEVICE_SERIAL_NUMBER |
设备序列号 |
MAC_ADDRESS |
设备出厂MAC地址 |
MANUFACTURING_DATE |
设备调测日期 |
VENDOR_NAME |
制造商名称 |
display device manuinfo chassis-only命令用来显示背板的电子标签信息。
【命令】
display device manuinfo chassis chassis-number chassis-only
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
【使用指导】
本命令仅缺省MDC支持。
【举例】
# 显示机框背板的电子标签信息。
<Sysname> display device manuinfo chassis 1 chassis-only
Chassis 1:
Chassis self:
DEVICE_NAME : backplane
DEVICE_SERIAL_NUMBER : 210235A36L1234567890
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2015-01-20
VENDOR_NAME : H3C
display device manuinfo fan命令用来显示风扇的电子标签信息。
【命令】
display device manuinfo chassis chassis-number fan fan-id
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
fan-id:表示设备上风扇的ID编号。
【使用指导】
本命令仅缺省MDC支持。
【举例】
# 显示指定风扇的电子标签信息。
<Sysname> display device manuinfo chassis 1 fan 1
Chassis 1:
Fan 1:
DEVICE_NAME : LSXM108CFAN
DEVICE_SERIAL_NUMBER : 210231A5WGX173000005
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2017-03-12
VENDOR_NAME : H3C
display device manuinfo power命令用来显示电源的电子标签信息。
【命令】
display device manuinfo chassis chassis-number power power-id
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
power-id:表示设备上电源的ID编号。
【使用指导】
本命令仅缺省MDC支持。
【举例】
# 显示指定电源的电子标签信息。
<Sysname> display device manuinfo chassis 1 power 7
Chassis 1:
Power 7:
DEVICE_NAME : PSR2400-54A
DEVICE_SERIAL_NUMBER : 210231A2SNH156000011
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2015-06-07
VENDOR_NAME : H3C
display device manuinfo power-tray命令用来显示电源框的电子标签信息。
【命令】
display device manuinfo chassis chassis-number power-tray pt-id
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:显示集群中指定成员设备上电源框的电子标签信息。chassis-number表示设备在集群中的成员编号。
pt-id:表示电源框的编号。
【举例】
# 显示成员设备1上电源框1的电子标签信息。
<Sysname> display device manuinfo chassis 1 power-tray 1
Chassis 1:
PowerTray 1:
DEVICE_NAME : PowerTray
DEVICE_SERIAL_NUMBER : 210235A36L1234567890
MAC_ADDRESS : NONE
MANUFACTURING_DATE : 2017-01-20
VENDOR_NAME : H3C
display device uptime命令用来显示设备最近一次启动后的运行时长。
【命令】
display device uptime
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【举例】
# 显示设备最近一次启动后的运行时长。
<Sysname> display device uptime
Slot No. Board Type Status Primary UP time(DD:HH:MM)
1 LSQM2MPUC0 Normal Master 0000:01:43
表1-9 display device uptime命令显示信息描述表
字段 |
描述 |
Board Type |
单板的硬件类型 |
Status |
单板状态: · Normal:正常工作状态 · Startup:启动中 · Wait:功率不足,不能上电 · Absent:没有插入单板 · Fault:单板出错,不能正常启动 · Disable:该槽位单板被隔离下电 |
Primary |
单板的主备角色,取值为: · Master:全局主用主控板 · Standby:全局备用主控板 |
UP time(DD:HH:MM) |
设备最近一次启动后的运行时长,格式为时:分:秒 |
display diagnostic-file命令用来显示设备上各种类型诊断文件的内容。
【命令】
display diagnostic-file [ bootlog | diagfile | diagmon | flowmon | logfile | tracefile ]* [ filename filename | [ [ last modification [ interval ] ] [ list ] ] ] [ chassis chassis-number [ slot slot-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
bootlog:显示启动日志文件的内容。仅缺省MDC支持该参数。
diagfile:显示diagfile文件的内容。
diagmon:显示诊断监控日志文件的内容。仅缺省MDC支持该参数。
flowmon:显示流监控日志文件的内容。仅缺省MDC支持该参数。
logfile:显示logfile文件的内容。
tracefile:显示tracefile文件的内容。
filename filename:指定文件名称。filename为1~32个字符的字符串,不区分大小写。
last modification [ interval ]:指定时间段,显示最后修改时间落在该时间段内的诊断日志文件。last modification表示距当前时刻的小时数,取值范围为1~86400,单位为小时。interval表示时间段的长度,取值范围为1~720,单位为小时。不指定last modification参数时,默认显示最后修改时间位于48小时至今的诊断日志文件;指定last modification参数不指定interval参数时,显示最后修改时间位于距当前时刻的last modification小时至今的诊断日志文件(最多48小时)。
举例一:将last modification配置为24,则表示显示最后修改时间位于最近一天内的诊断日志文件。
举例二:将last modification配置为6,interval配置为2,则表示显示最后修改时间位于6个小时前到4个小时前这段时间内的诊断日志文件。
list:预览显示文件列表。仅列出显示文件列表,不显示文件内容。
chassis chasiss-number:显示指定框的诊断文件信息。chasiss-number为框号,未指定时表示所有框。
slot slot-number:显示指定主控槽位的诊断文件信息。slot-number为主控槽位号,未指定时表示框内所有主控。
【使用指导】
设备会将运行过程中出现的异常、故障现象记录在诊断文件中。使用本命令可以查看这些诊断文件的内容,帮助用户定位、诊断故障。
【举例】
# 显示设备所有logfile文件。
<Sysname> display diagnostic-file logfile
#####lcc1#slot20#flash:#####
#####2020-03-28 22:01:17 lcc1#slot20#flash:/logfile8.log#####
@364739%Jan 17 14:05:08:541 2020 CR19000-20_3 ARP/6/DUPIFIP: -Chassis=1-Slot=9;
Duplicate address 23.1.80.1 on interface HundredGigE1/9/1/1.80, sourced from 9ce8-95c4-3b31
%@364740%Jan 17 14:05:08:541 2020 CR19000-20_3 ARP/6/DUPIFIP: -Chassis=1-Slot=9;
Duplicate address 23.1.81.1 on interface HundredGigE1/9/1/1.81, sourced from 9ce8-95c4-3b31
%@364741%Jan 17 14:05:08:541 2020 CR19000-20_3 ARP/6/DUPIFIP: -Chassis=1-Slot=9;
Duplicate address 23.1.82.1 on interface HundredGigE1/9/1/1.82, sourced from 9ce8-95c4-3b31
%@364742%Jan 17 14:05:08:541 2020 CR19000-20_3 ARP/6/DUPIFIP: -Chassis=1-Slot=9;
Duplicate address 23.1.83.1 on interface HundredGigE1/9/1/1.83, sourced from 9ce8-95c4-3b31
display diagnostic-information命令用来收集诊断信息。
【命令】
display diagnostic-information [ hardware | infrastructure | l2 | l3 | service ] [ key-info ] [ filename ] [ background ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
background:在后台收集诊断信息。不指定该参数时,如果设备生成的诊断信息较多,则收集诊断信息会耗费较长时间,且在诊断信息收集期间,命令行输入界面会被占用,用户不能输入并执行其它命令行。指定该参数后,系统会在后台收集诊断信息,在此过程中,用户可在命令行输入界面输入并执行其它命令行。
hardware:收集硬件相关的诊断信息。
infrastructure:收集基础模块的诊断信息。
l2:收集二层特性相关诊断信息。
l3:收集三层特性相关诊断信息。
service:收集上层业务模块相关诊断信息。
key-info:收集关键诊断信息。当设备异常或者运行时间较长时,可能会产生较多诊断信息,此时,使用该关键字,即可以收集到关键的诊断信息,又可以缩短诊断信息的收集时间。不指定该参数时,收集当前全部诊断信息。
filename:表示将收集到的诊断信息保存到指定文件。filename表示文件的名称,后缀必须为“.tar.gz”。不指定该参数时,用户可根据提示信息选择将诊断信息保存到指定文件或者是直接显示诊断信息。
【使用指导】
在日常维护或系统出现故障时,为了便于问题定位,用户需要查看各个模块的诊断信息。因为各个功能模块都有其对应的运行信息,所以一般情况下,用户需要逐条运行相应的display命令。为便于一次性收集更多信息,用户可以在任意视图下执行display diagnostic-information命令,收集多个模块的诊断信息。
使用该命令,用户可以直接显示指定的诊断信息或者将诊断信息直接保存到指定文件,因为诊断信息较多,系统会自动将该文件压缩后保存,文件名后缀为“.tar.gz”。如果要在设备上查看该文件的内容,请执行以下操作:
(1) 使用tar extract命令将文件XXXX.tar.gz解包成文件XXXX.gz。
(2) 使用gunzip命令将文件XXXX.gz解包成文件XXXX。
(3) 使用more命令查看文件XXXX的内容。
如果收集诊断文件过程半途中止,可能导致gunzip命令无法正常解压,但诊断文件中仍包括已经生成的诊断信息,可以导出到PC上使用Linux系统下的gunzip -c命令解压查看。
未指定hardware、infrastructure、l2、l3和service参数时,将收集设备产生的所有诊断信息。
不指定filename参数执行display diagnostic-information命令,当系统提示用户输入文件名时直接回车,设备会自动将当前诊断信息保存到一个新文件,并使用设备名称和当前系统时间为该文件命名,以免和现有文件重名,导致现有文件被覆盖。如果设备名称中包含“/”、“\”、“:”、“*”、“?”、“<”、“>”、“|”、“"”等特殊字符,在给诊断文件命名时,这些特殊字符会被转换为下划线“_”。比如设备的名称为A/B,设备会使用形如flash:/diag_A_B_20160101-000438.tar.gz的字符串为新生成的诊断文件命名。
该命令不支持“|”、“>”和“>>”参数。
执行本命令收集诊断信息时,请不要配置设备,以免影响收集结果。
【举例】
# 收集系统当前各个功能模块运行的统计信息。
<Sysname> display diagnostic-information
Save or display diagnostic information (Y=save, N=display)? [Y/N]:n
===============================================
===============display clock===============
14:03:55 UTC Thu 01/05/2012
=================================================
===============display version===============
其他显示信息略……。
# 将收集到的诊断信息保存到缺省文件。
<Sysname> display diagnostic-information
Save or display diagnostic information (Y=save, N=display)? [Y/N]:y
Please input the file name(*.tar.gz)[flash:/diag_Sysname_20160101-024601.tar.gz]:
Diagnostic information is outputting to flash:/diag_Sysname_20160101-024601.tar.gz.
Please wait...
Save successfully.
请在“Please input the file name”提示信息处,直接回车。
# 将收集到的诊断信息保存到文件test.tar.gz。
<Sysname> display diagnostic-information test.tar.gz
Diagnostic information is outputting to flash:/test.tar.gz.
Please wait...
Save successfully.
# 后台收集诊断信息到缺省文件。
<Sysname> display diagnostic-information background
Please input the file name (*.tar.gz)[flash:/diag_Sysname_20201215-163501.tar.gz]:
Diagnostic information is outputting to flash:/diag_Sysname_20201215-163501.tar.gz in the background.
【相关命令】
· gunzip(基础配置命令参考/文件系统管理)
· more(基础配置命令参考/文件系统管理)
· tar extract(基础配置命令参考/文件系统管理)
display environment命令用来显示设备上温度传感器的温度信息。
【命令】
display environment [ chassis chassis-number [ slot slot-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:显示集群中指定成员设备上温度传感器的温度信息。chassis-number表示设备在集群中的成员编号。不指定该参数时,显示所有成员设备的对应信息。
slot slot-number:显示设备中指定单板上的温度传感器的温度信息。slot-number表示单板所在的槽位号。不指定该参数时,显示所有单板的对应信息。
【使用指导】
不指定chassis参数时,显示的是集群中所有温度传感器的温度信息;指定chassis但不指定slot参数时,显示的是指定成员设备上所有温度传感器的温度信息。
本命令仅缺省MDC支持。
【举例】
# 显示设备上所有温度传感器的温度信息。
<Sysname> display environment
System temperature information (degree centigrade):
------------------------------------------------------------------------------
Slot Sensor Temperature Status LowerLimit WarningLimit AlarmLimit ShutdownLimit
1/8 Inflow 1 25 Normal 0 50 60 127
1/8 Hotspot 1 31 Normal 0 85 92 127
1/8 Hotspot 2 31 Normal 0 88 102 127
1/8 Hotspot 3 32 Normal 0 80 90 127
表1-10 display environment命令显示信息描述表
字段 |
描述 |
System Temperature information (degree centigrade) |
系统温度信息,单位为摄氏度 |
Slot |
机框编号/槽位编号。当显示数字时表示指定slot上温度传感器的温度信息; |
sensor |
温度传感器 · hotspot:表示热点温度传感器 · inflow:表示入风口温度传感器 |
Temperature |
当前温度 |
LowerLimit |
低温告警门限。当显示为NA时,表示不支持该门限 |
WarningLimit |
一般级(Warning)高温告警门限。当显示为NA时,表示不支持该门限 |
AlarmLimit |
严重级(Alarm)高温告警门限。当显示为NA时,表示不支持该门限 |
ShutdownLimit |
关断级(Shutdown)高温告警门限,当温度传感器的温度大于该门限时,设备会自动关闭。当显示为NA时,表示不支持该门限 |
display fan命令用来显示风扇的工作状态。
【命令】
display fan [ chassis chassis-number [ fan-id ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:表示设备在集群中的成员编号。不指定chassis参数时,表示所有风扇。
fan-id:表示设备内置风扇的编号。不指定该参数时,表示指定位置的所有风扇。
【使用指导】
本命令仅缺省MDC支持。
【举例】
# 显示设备上所有风扇的工作状态。
<Sysname> display fan
Frame Frame-State Fan State Type Speed Mode
--------------------------------------------------------------------------------
---
1/1 Normal 1 Normal FAN-120B-2-A 4598(38%) Silence
1/1 Normal 2 Normal FAN-120B-2-A 4598(38%) Silence
1/2 Normal 1 Normal FAN-120B-2-A 4649(38%) Silence
1/2 Normal 2 Normal FAN-120B-2-A 4575(38%) Silence
1/3 Normal 1 Normal FAN-120B-2-A 4702(39%) Silence
1/3 Normal 2 Normal FAN-120B-2-A 4795(39%) Silence
1/4 Normal 1 Normal FAN-120B-2-A 4786(39%) Silence
1/4 Normal 2 Normal FAN-120B-2-A 4711(39%) Silence
1/5 Normal 1 Normal FAN-120B-2-A 4672(38%) Silence
1/5 Normal 2 Normal FAN-120B-2-A 4581(38%) Silence
1/6 Normal 1 Normal FAN-120B-2-A 8630(71%) Silence
1/6 Normal 2 Normal FAN-120B-2-A 8690(72%) Silence
表1-11 display fan命令显示信息描述表
字段 |
描述 |
Frame |
(CR19000-20暂不支持)机框编号/风扇框编号 |
Frame-State |
(CR19000-20暂不支持)机框状态: · Absent:机框不在位 · Fault:机框故障 · Normal:机框正常工作 |
Fan |
扇叶序号 |
State |
风扇状态: · Absent:风扇不在位 · Fault:风扇故障 · Normal:风扇正常工作 |
Type |
风扇框型号 |
Speed |
风扇转速和转速比例 |
Mode |
风扇模式: · Low-temperature:低温模式 · Silence:静音模式 · Command:命令模式 · Equip:装备模式 |
display health命令用来显示CPU和内存的使用情况。
【命令】
display health [ chassis chassis-number [ slot slot-number [ cpu cpu-number ] ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
chassis chassis-number [ slot slot-number [ cpu cpu-number ] ]:显示指定单板上CPU和内存的使用情况。chassis-number表示设备在集群中的成员编号,不指定该参数时,显示所有成员设备上CPU和内存的使用情况。slot-number表示单板所在的槽位号,指定chassis不指定slot参数时,显示指定成员设备上CPU和内存的使用情况。cpu-number表示CPU的槽位号,指定chassis和slot、不指定cpu参数时,显示指定单板上CPU和内存的使用情况。
【举例】
# 显示所有slot上CPU和内存的使用情况。
<Sysname> display health
Chassis Slot CPU Role CPU Usage(%) Memory Usage(%) Used/Total(MB)
1 8 0 MPU(Master) 0 23 3821/15960
表1-12 display health命令显示信息描述表
字段 |
描述 |
Role |
成员设备在集群中的角色,取值为: · MPU(Master)表示全局主用主控板 · MPU(Standby)表示全局备用主控板 · LPU表示接口板 |
CPU Usage(%) |
CPU利用率信息,表示系统在过去5秒内CPU利用率的平均值 |
Memory Usage(%) |
单板上当前的内存利用率 |
Used/Total(MB) |
单板上当前已使用的内存大小/单板上内存总大小,单位为MB |
display kernel memory alloc-failure命令用来显示内核内存申请失败信息。
【命令】
display kernel memory alloc-failure [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【举例】
# 显示内核内存申请失败信息。
<System> display kernel memory alloc-failure
kmalloc_tag failures: 55.
kcalloc_tag failures: 0.
kzalloc_tag failures: 0.
krealloc_tag failures: 0.
kmem_cache_alloc_tag failures: 0.
表1-13 display kernel memory alloc-failure 命令显示信息描述表
字段 |
描述 |
kmalloc_tag failures |
调用kmalloc_tag申请内存失败的次数 |
kcalloc_tag failures |
调用kcalloc_tag申请内存失败的次数 |
kzalloc_tag failures |
调用kzalloc_tag申请内存失败的次数 |
krealloc_tag failures |
调用krealloc_tag申请内存失败的次数 |
kmem_cache_alloc_tag failures |
调用kmem_cache_alloc_tag申请内存失败的次数 |
display kernel memory fragment free命令用来显示内核空间空闲内存的统计信息。
【命令】
display kernel memory fragment free [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【举例】
# 显示内核空间空闲内存的统计信息。
<Sysname> display kernel memory fragment free
Kernel memory free ratio: 0.13%
cfq_io_context memory free (in kbytes): 0
LFIB_NhlfeEntryCache26 memory free (in kbytes): 0
LFIB_NhlfeEntryCache74 memory free (in kbytes): 0
L2VFIB_TUNNELBMP_Cache memory free (in kbytes): 0
NAT_SESSION_EXT_INFO memory free (in kbytes): 0
ARP_VSISUP_Entry_cache memory free (in kbytes): 0
LFIB_NhlfeEntryCache1 memory free (in kbytes): 0
FVN_FwdCache19 memory free (in kbytes): 0
---- More ----
表1-14 display kernel memory fragment 命令显示信息描述表
字段 |
描述 |
Kernel memory free ratio |
内核空间空闲内存占内核空间总内存的比例 |
cfq_io_context memory free (in kbytes) |
Slab名为cfq_io_context的空闲内存大小,单位为千字节 |
display memory命令用来显示内存使用情况。
【命令】
display memory [ summary ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
summary:显示内存使用情况的简要信息。不指定该参数时,显示内存使用情况的详细信息。
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示所有主控板。
cpu cpu-number:表示CPU编号。
【使用指导】
登录MDC后执行该命令,会显示该MDC可使用的内存的使用情况。
当显示信息中某一行所有参数的取值均显示为“--”时,可能原因为命令行从设备内部数据库获取数据失败,请稍候重试。
【举例】
# 显示设备的内存使用情况的详细信息。
<Sysname> display memory
Memory statistics are measured in KB:
Chassis 1 Slot 8:
Total Used Free Shared Buffers Cached FreeRatio
Mem: 16343156 4249648 12093508 0 48 540000 76.1%
-/+ Buffers/Cache: 3709600 12633556
Swap: 0 0 0
# 显示设备的内存使用情况的简要信息。
<Sysname> display memory summary
Memory statistics are measured in KB:
Chassis Slot CPU Total Used Free Buffers Caches FreeRatio
1 8 0 16343156 4249488 12093668 48 540024 76.1%
表1-15 display memory命令显示信息描述表
字段 |
描述 |
Memory statistics are measured in KB: |
系统内存使用情况,以下统计信息均以KB为单位 |
Mem |
内存使用信息 |
Total |
系统可分配的物理内存的大小 设备总物理内存分为不可分配物理内存和可分配物理内存。其中,不可分配物理内存用于内核代码段存储、内核管理开销以及ISSU功能运行等;可分配物理内存用于支撑业务模块的运行、文件存储等操作。不可分配内存的大小由设备根据系统运行需要自动计算划分,可分配物理内存的大小等于设备总物理内存减去不可分配内存的大小 |
Used |
整个系统已用的物理内存大小 |
Free |
整个系统可用的物理内存大小 |
Shared |
多个进程共享的物理内存总额。取值为“--”时,表示不支持统计该参数的值 |
Buffers |
已使用的文件缓冲区的大小。取值为“--”时,表示不支持统计该参数的值 |
Cached |
高速缓冲寄存器已使用的内存大小。取值为“--”时,表示不支持统计该参数的值 |
Caches |
高速缓冲寄存器已使用的内存大小 |
FreeRatio |
整个系统物理内存的空闲率 |
-/+ buffers/cache |
-/+ Buffers/Cache:used = Mem:Used – Mem:Buffers – Mem:Cached,表示应用程序已用的物理内存大小 -/+ Buffers/Cache:free = Mem:Free + Mem:Buffers + Mem:Cached,表示应用程序可用的物理内存大小 |
Swap |
交换分区的使用信息 |
display memory dma命令用来显示DMA内存的使用情况。
【命令】
display memory dma [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【举例】
# 显示DMA内存使用相关信息。
<System> display memory dma
DMA memory statistics measured in KB on the device:
Total Used Free FreeRatio
16384 6140 10244 63%
表1-16 display memory dma 命令显示信息描述表
字段 |
描述 |
DMA memory statistics measured in KB |
系统使用DMA内存情况,单位为KB |
Total |
内存分片的总个数,为Free和Used之和 |
Used |
系统已使用的DMA内存大小 |
Free |
系统可使用的DMA内存大小 |
FreeRatio |
Free与Total的比率,可以反映系统DMA内存的空闲率 |
display memory-threshold命令用来显示内存告警门限相关信息。
【命令】
display memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示全局主用主控板。
cpu cpu-number:表示CPU编号。
【使用指导】
仅缺省MDC支持本命令。
当设备已经使用的物理内存大小超过内存某个告警门限阈值时,系统会认为发生了一次该类型内存异常,并记录第一次、最近一次发生异常的时间,以及这段时间内发生的该类异常的次数。如果想了解该类异常的详细情况,请查看日志信息,可按日志摘要关键字“MEM_EXCEED_THRESHOLD”或“MEM_BELOW_THRESHOLD”进行搜索。
【举例】
# 显示内存告警门限相关信息。
<Sysname> display memory-threshold
Memory usage threshold: 100%
Free-memory thresholds:
Minor: 256M
Severe: 128M
Critical: 64M
Normal: 304M
Early-warning: 320M
Secure: 368M
Current free-memory state: Normal (secure)
Free-memory event statistics:
[Back to secure state]
First notification: 0.0
Latest notification: 0.0
Total number of notifications sent: 0
[Entered early-warning state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Back to normal state]
First notification: 0.0
Latest notification: 0.0
Total number of notifications sent: 0
[Entered minor alarm state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Back to minor alarm state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Entered severe alarm state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Back to severe alarm state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
[Entered critical alarm state]
First notification at: 0.0
Latest notification at: 0.0
Total number of notifications sent: 0
表1-17 display memory-threshold命令显示信息描述表
字段 |
描述 |
Memory usage threshold |
内存利用率阈值 |
Free memory thresholds Minor Severe Critical Normal |
剩余内存门限阈值: · Minor:一级告警门限,单位为MB · Severe:二级告警门限,单位为MB · Critical:三级告警门限,单位为MB · Normal:恢复到正常状态的阈值,单位为MB · Early-warning:预警门限,单位为MB · Secure:恢复预警门限状态的阈值,单位为MB |
Current memory state |
系统当前内存使用状态: · Normal:正常状态 · Minor:一级告警门限状态 · Severe:二级告警门限状态 · Critical:三级告警门限状态 · Normal (early-warning):预告警状态 · Normal (secure):安全状态 |
Event statistics: |
门限事件统计信息,事件分为: · Back to secure state:恢复到预警前的状态 · Entered early-warning state:进入预告警门限状态 · Back to normal state:内存恢复到正常状态 · Entered minor low-memory state:进入一级低内存状态 · Back to minor low-memory state:恢复到一级低内存前的状态 · Entered severe low-memory state:进入二级低内存状态 · Back to severe low-memory state:恢复到二级低内存前的状态 · Entered critical low-memory state:进入三级低内存状态 |
First notification at |
事件第一次发生的时间,格式yyyy-mm-dd hh:mm:ss.msec |
Latest notification at |
事件最近一次发生的时间,格式yyyy-mm-dd hh:mm:ss.msec |
Total number of notifications send |
事件发生的总次数 |
display memory-threshold dma命令用来显示DMA内存告警相关信息。
【命令】
display memory-threshold dma [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【举例】
# 显示DMA内存告警相关信息。
<Sysname> display memory-threshold dma
Free DMA memory thresholds:
Critical: 2048KB
Normal: 4096KB
Current DMA memory state: Normal
Free memory event statistics:
[Back to normal state]
First notification: 0.0
Latest notification: 0.0
Total number of notifications sent: 0
[Entered to critcal state]
First notification: 0.0
Latest notification: 0.0
Total number of notifications sent: 0
表1-18 display memory-threshold dma 命令显示信息描述表
字段 |
描述 |
Free DMA memory thresholds: Critical: Normal: |
DMA内存告警阈值(单位为KB): · Critical:告警阈值 · Normal:告警恢复阈值 |
Current DMA memory state |
DMA内存的当前状态: · Critical:告警状态 · Normal:正常状态 |
Free memory event statistics: |
告警事件统计信息,事件分为: · Back to normal state:内存恢复到正常状态 · Entered to critcal state:进入告警状态 |
First notification |
告警事件第一次发生的时间,格式yyyy-mm-dd hh:mm:ss.msec |
Latest notification |
告警事件最近一次发生的时间,格式yyyy-mm-dd hh:mm:ss.msec |
Total number of notifications sent |
告警事件发生的总次数 |
display non-stop-routing status命令用来显示所有支持NSR(Nonstop Routing,不间断路由)功能模块的NSR状态信息。
【命令】
display non-stop-routing status
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【举例】
# 显示所有支持NSR功能模块的NSR状态信息。
<Sysname> display non-stop-routing status
NSR status: Not ready
Module name(instance name/process ID) Status
--------------------------------------------------------------
MSDP Not ready
OSPF(1) Ready
OSPF(2) Ready
BGP(default) Ready
BGP(aaa) Ready
PIM Not configured
表1-19 display non-stop-routing status命令显示信息描述表
字段 |
描述 |
NSR status |
系统的NSR状态: · Ready:系统的NSR处于稳定状态,即设备上所有使能NSR的模块的NSR状态均处于稳定状态 · Not ready:系统的NSR处于未稳定状态,即设备上有些模块的NSR状态处于未稳定状态 · Not configured:系统的NSR处于未使能状态,即设备上没有模块使能NSR · No standby:由于没有备用硬件,而导致设备无法实施NSR |
Module name(instance name/process ID) |
支持NSR功能的模块名称(实例名称/进程编号)。部分模块用instance name区分不同的实例,例如BGP (default);用process ID区分不同的进程,例如OSPF(1)。当模块无具体实例名称或进程时,仅显示模块名称,例如MSDP |
Status |
NSR的状态信息: · Ready:NSR处于稳定状态 · Not ready:NSR处于未稳定状态,此时不能进行进程倒换或者主备倒换 · Not configured:NSR处于未使能状态,此时不能进行进程倒换或者主备倒换 |
display power命令用来显示设备电源的信息。
【命令】
display power [ chassis chassis-number [ power-id | verbose ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:表示设备在集群中的成员编号。不指定该参数时,表示所有电源。
power-id:表示电源模块的编号。不指定该参数时,表示指定位置的所有电源。
verbose:显示电源的详细信息。不指定该参数时,显示电源的简要信息。
【使用指导】
本命令仅缺省MDC支持。
【举例】
# 显示设备电源的简要信息。
<Sysname> display power
Chassis InPower(W) OutPower(W)
----------------------------------------------
1 1565 1480.34
PowerID. State Type InVoltage(V) InPower(W) OutVoltage(V)
OutCurrent(A) OutPower(W)
--------------------------------------------------------------------------------
--------------------------------
1/1 Absent N/A -- -- --
-- --
1/2 Absent N/A -- -- --
-- --
1/3 Absent N/A -- -- --
-- --
1/4 Normal PSR2400-54A 238 804 53.85
14.25 767.36
1/5 Normal PSR2400-54A 238 761 53.81
13.25 712.98
1/6 Absent N/A -- -- --
-- --
1/7 Absent N/A -- -- --
-- --
1/8 Absent N/A -- -- --
表1-20 display power命令显示信息描述表
字段 |
描述 |
|
PowerID |
机框编号/电源模块编号 |
|
State |
电源模块的状态 · Absent:电源不在位 · Normal:电源正常工作 · Fault:电源故障 |
|
Type |
电源型号 |
|
InVoltage(V) |
电源输入电压,单位为伏,显示为“--”表示设备暂不支持统计该信息 |
|
InPower(W) |
电源输入功率,单位为瓦,显示为“--”表示设备暂不支持统计该信息 |
|
OutVoltage(V) |
电源输出电压,单位为伏,显示为“--”表示设备暂不支持统计该信息 |
|
OutCurrent(A) |
电源输出电流,单位为安,显示为“--”表示设备暂不支持统计该信息 |
|
OutPower(W) |
电源输出功率,单位为瓦,显示为“--”表示设备暂不支持统计该信息 |
|
# 显示电源的详细信息。
<Sysname> display power chassis 1 verbose
Chassis InPower(W) OutPower(W)
----------------------------------------------
1 1528 1439.18
System power information on chassis 1:
Power modules installed: 2
Power modules usable: 2
Module capacity: 2400(W)
Total DC output: 26.75(A)
PowerID. State Type InVoltage(V) InPower(W) OutVoltage(V)
OutCurrent(A) OutPower(W)
--------------------------------------------------------------------------------
--------------------------------
1/1 Absent N/A -- -- --
-- --
1/2 Absent N/A -- -- --
-- --
1/3 Absent N/A -- -- --
-- --
1/4 Normal PSR2400-54A 238 787 53.85
13.75 740.43
1/5 Normal PSR2400-54A 238 741 53.75
13.00 698.75
1/6 Absent N/A -- -- --
-- --
1/7 Absent N/A -- -- --
-- --
1/8 Absent N/A -- -- --
-- --
Board power information:
Slot Type Current(A) Power(W) Status
------------------------------------------------------------------
1/0 NA -- 0(0) Absent
1/1 NA -- 0(0) Absent
1/2 CR-19K-LPU-CC08 -- 878(0)* Normal
1/3 CR-19K-LPU-4004 -- 626(0)* Normal
1/4 NA -- 0(0) Absent
1/5 NA -- 0(0) Absent
1/6 NA -- 0(0) Absent
1/7 NA -- 0(0) Absent
1/8 CR-19K-MPU-08A -- 47(0)* Normal
1/9 CR-19K-MPU-08A -- 47(0)* Startup
1/10 CR-19K-SFU-08C -- 133(0)* Normal
1/11 NA -- 0(0) Absent
1/12 CR-19K-SFU-08C -- 133(0)* Normal
1/13 NA -- 0(0) Absent
1/14 NA -- 0(0) Absent
1/15 NA -- 0(0) Absent
表1-21 display power verbose命令显示信息描述表
|
字段 |
描述 |
|
System power information |
设备上电源系统的相关信息 |
|
|
|
Power modules installed |
设备中已安装的电源模块数量 |
|
|
Power modules usable |
设备中可用的电源模块数量 |
|
Module capacity |
每个电源的功率,单位为瓦 |
|
|
Total DC output |
设备中所有电源模块输出电流值的和,单位为安 |
|
|
PowerID |
设备上的电源模块编号 |
|
|
State |
电源模块的状态 · Absent:电源不在位 · Normal:电源正常工作 · Fault:电源故障 |
|
|
Type |
电源型号 |
|
|
InVoltage(V) |
电源输入电压,单位为伏,显示为“--”表示设备暂不支持统计该信息 |
|
|
InPower(W) |
电源输入功率,单位为瓦,显示为“--”表示设备暂不支持统计该信息 |
|
|
OutVoltage(V) |
电源输出电压,单位为伏,显示为“--”表示设备暂不支持统计该信息 |
|
|
OutCurrent(A) |
电源输出电流,单位为安,显示为“--”表示设备暂不支持统计该信息 |
|
|
OutPower(W) |
电源输出功率,单位为瓦,显示为“--”表示设备暂不支持统计该信息 |
|
|
Board power information: |
各单板对当前电源模块的使用情况 |
|
|
Slot |
单板所在的slot编号 |
|
|
Type |
单板的类型 |
|
|
Current(A) |
单板当前的输入电流,单位为安,显示为“--”表示设备暂不支持统计该信息 |
|
|
Power(W) |
单板的额定功率,单位为瓦,显示为“--”表示设备暂不支持统计该信息 |
|
|
Status |
单板状态 · Absent:表示该槽位没有插入单板 · Startup:表示该板为启动状态 · Normal:表示该板处于正常工作状态 · Fault:表示该槽位单板出错,不能正常启动 · Disable:表示单板被手工下电(执行命令power-supply off) · Wait:表示单板等待上电中 |
|
|
display power-supply命令用来显示电源管理功能的相关信息。
【命令】
display power-supply [ chassis chassis-number ] [ verbose ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:显示指定成员设备上电源管理功能的相关信息。chassis-number表示设备在集群中的成员编号。不指定该参数时,表示所有成员设备。
verbose:显示电源管理功能的详细信息。不指定该参数时,显示电源管理功能的简要信息。
【使用指导】
仅缺省MDC支持本命令。
【举例】
# 显示电源管理功能的相关信息。
<Sysname> display power-supply
Chassis Policy Redundant Num Board Num(Power On) Module Capacity(W)
Power Available(W) Power Used(W)
-------------------------------------------------------------------------------------------------------------------
0 Enabled 0 2 2400
2476 2324
表1-22 display power-supply命令输出信息描述表
字段 |
描述 |
Chassis |
框号 |
Policy |
电源策略的状态,取值为: · Enabled:开启 · Disabled:关闭 |
Redundant Num |
冗余电源个数 |
Board Num(Power On) |
已上电的单板个数 |
Module Capacity(W) |
单个电源的容量,单位为瓦 |
Power Available(W) |
当前可用功率,单位为瓦 |
Power Used(W) |
当前已用功率,单位为瓦 |
# 显示电源管理功能的详细信息。
<Sysname> display power-supply verbose
Chassis Policy Redundant Num Board Num(Power On) Module Capacity(W)
Power Available(W) Power Used(W)
--------------------------------------------------------------------------------
-----------------------------------
1 Enabled 0 4 2400
1442 3358
Board power supply information:
Slot Type Priority Watts(W) ActualWatts(W)
Status
--------------------------------------------------------------------------------
------
1/0 NA 0(0) 0(0) NA
Absent
1/1 CR-LPU-4004 5(5) 626(0)* NA
Normal
1/2 CR-19K-LPU-CC08 5(5) 878(0)* NA
Normal
1/3 NA 0(0) 0(0) NA
Absent
1/4 NA 0(0) 0(0) NA
Absent
1/5 NA 0(0) 0(0) NA
Absent
1/6 NA 0(0) 0(0) NA
Absent
1/7 NA 0(0) 0(0) NA
Absent
1/8 CR-19K-MPU-08A NA(NA) 0(47)* NA
Normal
1/9 CR-19K-MPU-08A NA(NA) 0(47)* NA
Startup
1/10 NA 0(0) 0(0) NA
Absent
1/11 NA 0(0) 0(0) NA
Absent
1/12 CR-19K-SFU-08C -1(-1) 133(0)* NA
Normal
1/13 NA 0(0) 0(0) NA
Absent
1/14 CR-19K-SFU-08C -1(-1) 133(0)* NA
Normal
1/15 NA 0(0) 0(0) NA
Absent
表1-23 display power-supply verbose命令输出信息描述表
字段 |
描述 |
Chassis |
框号 |
Policy |
电源策略的状态,取值为: · Enabled:开启 · Disabled:关闭 |
Redundant Num |
冗余电源个数 |
Board Num(Power On) |
已上电的单板个数 |
Module Capacity(W) |
单个电源的容量,单位为瓦 |
Power Available(W) |
当前可用功率,单位为瓦 |
Power Used(W) |
当前已用功率,单位为瓦 |
Board power supply information |
单板供电信息 |
Slot |
成员设备的编号/成员设备上单板所在的槽位号 |
Type |
单板的硬件类型 |
Priority |
当前上电优先级(配置的优先级) 若配置的优先级值为-1,则当前上电优先级的值为默认值;主控板的优先级值为NA |
Watts(W) |
单板分配的最大功率(为单板预留的功率) |
ActualWatts(W) |
单板实际使用的功率 |
Status |
单板状态 · Absent:表示该槽位没有插入单板 · Startup:表示该板为启动状态 · Normal:表示该板处于正常工作状态 · Fault:表示该槽位单板出错,不能正常启动 · Disable:表示单板被手工下电(执行命令power-supply off) · Wait:表示单板等待上电中 |
display resource-monitor命令用来显示资源监控功能的相关信息。
【命令】
display resource-monitor [ resource resource-name ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
resource resource-name:需要监测的资源的名称。参数的取值请参见表1-41。
slot slot-number:显示指定单板的资源监控功能的相关信息。slot-number表示单板所在的槽位号。不指定该参数时,则表示所有单板。
chassis chassis-number slot slot-number:显示指定单板的资资源监控功能的相关信息。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,则表示集群中的所有单板。
cpu cpu-number:显示指定CPU的资源监控功能的相关信息。cpu-number表示需要检测的资源所在CPU的编号。
【使用指导】
仅缺省MDC支持本命令。
【举例】
# 显示ARP资源监控的相关信息。
<Sysname> display resource-monitor resource arp
Minor alarms resending: Enabled
Chassis 1 Slot 1:
Resource Minor Severe Free/Total
(%) (%) (absolute)
arp 50 20 90095/90098
表1-24 display resource-monitor命令显示信息描述表
字段 |
描述 |
Minor alarms resending |
周期发送低级别资源告警通知功能的开启状态: · Enabled:表示该功能已开启 · Disabled:表示该功能未开启 |
Resource |
监控资源的名称 |
Minor (%) |
低级别告警门限,单位为百分比 |
Severe (%) |
高级别门限,单位为百分比 |
Free/Total (absolute) |
剩余资源的数量/该资源的总数,用绝对值形式表示 |
【相关命令】
· resource-monitor minor resend enable
· resource-monitor resource
display scheduler job命令用来显示Job的配置信息。
【命令】
display scheduler job [ job-name ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
job-name:Job的名称,为1~47个字符的字符串,区分大小写。不指定该参数时,则显示所有Job的配置信息。
【举例】
# 查看所有Job的配置信息。
<Sysname> display scheduler job
Job name: saveconfig
copy startup.cfg backup.cfg
Job name: backupconfig
Job name: 123
以上显示信息表明,设备当前配置了3个Job,分别显示了Job的名称,以及为Job分配的命令(如果没有为Job分配命令,则只显示Job的名称),不同Job间用空行分隔。
display scheduler logfile命令用来显示Job的执行日志信息。
【命令】
display scheduler logfile
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【举例】
# 显示Schedule日志文件的相关信息。
<Sysname> display scheduler logfile
Logfile Size: 1902 Bytes.
Job name : shutdown
Schedule name : shutdown
Execution time : Tue Dec 27 10:44:42 2011
Completion time : Tue Dec 27 10:44:47 2011
--------------------------------- Job output -----------------------------------
<Sysname>system-view
System View: return to User View with Ctrl+Z.
[Sysname]interface rang gigabitethernet 1/2/0/1 to gigabitethernet 1/2/0/3
[Sysname-if-range]shutdown
表1-25 display scheduler logfile命令显示信息描述表
字段 |
描述 |
Logfile Size |
Schedule日志文件的大小,单位为字节 |
Job name |
Job的名称 |
Schedule name |
Schedule的名称 |
Execution time |
开始执行Job的时间 |
Completion time |
Job执行结束的时间(没有调度的或者没有分配命令的Job,均不会显示该信息) |
Job output |
Job中的命令执行时的输出信息 |
【相关命令】
· reset scheduler logfile
display scheduler reboot命令用来显示定时重启功能的相关配置。
【命令】
display scheduler reboot
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【举例】
# 显示定时重启功能的相关配置。
<Sysname> display scheduler reboot
System will reboot at 16:32:00 05/23/2011 (in 1 hours and 39 minutes).
【相关命令】
· scheduler reboot at
· scheduler reboot delay
display scheduler schedule命令用来显示Schedule的相关信息。
【命令】
display scheduler schedule [ schedule-name ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
schedule-name:Schedule的名称,为1~47个字符的字符串,区分大小写。如果不指定该参数,则显示所有Schedule的信息。
【举例】
# 显示所有Schedule的信息。
<Sysname> display scheduler schedule
Schedule name : shutdown
Schedule type : Run once after 0 hours 2 minutes
Start time : Tue Dec 27 10:44:42 2011
Last execution time : Tue Dec 27 10:44:42 2011
Last completion time : Tue Dec 27 10:44:47 2011
Execution counts : 1
-----------------------------------------------------------------------
Job name Last execution status
shutdown Successful
表1-26 display scheduler schedule命令显示信息描述表
字段 |
描述 |
Schedule name |
Schedule的名称 |
Schedule type |
Schedule的执行时间配置。如果没有为Schedule配置执行时间,则不会显示该信息 |
Start time |
Schedule第一次开始执行的时间。如果没有为Schedule配置执行时间,则不会显示该信息 |
Last execution time |
Schedule上一开始执行的时间 · 如果没有为Schedule配置执行时间,则不会显示该信息 · 如果还没有执行,则显示Yet to be executed |
Last completion time |
Schedule上一次执行完成的时间。如果没有为Schedule配置执行时间,则不会显示该信息 |
Execution counts |
Schedule已经执行的次数。如果Schedule还没有执行,则不会显示该信息 |
Job name |
Schedule下关联的Job的名称 |
Last execution status |
Job上一次被执行的状态(Job下分配的命令是否执行以及执行结果,请通过display scheduler logfile命令查看) · Successful:表示执行成功 · Failed:表示执行失败 · Waiting:表示正在等待被执行 · In process:表示正在执行 · -NA-:表示还没有到执行时间 |
display system stable state命令用来显示系统的稳定状态。
【命令】
display system stable state [ mdc { mdc-id | all } ] [ summary ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
mdc { mdc-id | all }:显示指定或所有MDC的系统稳定状态。mdc-id表示MDC的编号。
summary:显示系统稳定状态的汇总信息,包括CPU的运行状态、主备状态、NSR和集群的稳定状态。不指定该参数时,显示CPU的运行状态、主备状态,以及CPU运行状态的详细信息。
【使用指导】
不指定mdc参数时,显示系统的稳定状态。
在进行ISSU升级或主备倒换前,请先执行该命令,检查设备是否处于稳定状态。如果System State未处于Stable状态,不能进行ISSU升级;如果Redundancy State未处于Stable状态,不能进行主备倒换。
设备/MDC启动需要一定的时间,才能达到Stable状态。如果设备/MDC长时间未能进入Stable状态,可通过该命令的显示信息找出未稳定的设备/MDC,根据其具体状态,采取进一步措施。
系统处于不稳定状态时,需要结合相关命令查看设备的具体情况。例如:
· 通过display device命令查看设备是否处于故障状态。
· 通过display ha service-group命令查看HA服务组的状态,以找出未批备完成的模块。
· 通过Probe视图下的display system internal process state命令查看服务启动状态。
操作时,建议多次执行命令,以确认稳定状态的连续性。
【举例】
# 显示系统的稳定状态的汇总信息。
<Sysname> display system stable state summary
System state : Stable
Redundancy state : No redundancy
NSR state : No standby
# 显示系统的稳定状态。
<Sysname> display system stable state
System state : Not ready
Redundancy state : Not ready
Chassis Slot CPU Role State
1 8 0 Active Stable
* 1 1 0 Other Board inserted
* 1 2 0 Other Kernel initiating
* 1 3 0 Other Board inserted
* 1 9 0 Standby Board inserted
* 1 10 0 Other Board inserted
表1-27 display system stable state命令显示信息描述表
字段 |
描述 |
System state |
系统状态: · Stable:稳定运行 · Not ready:未稳定,此时不能进行ISSU升级 |
Redundancy state |
主备状态: · Stable:主备状态稳定,可以倒换 · No redundance:系统无冗余,不能倒换 · Not ready:未稳定,不可以倒换 |
Role |
单板在系统中的身份: · Active:主用主控板 · Standby:备用主控板,提供冗余备份 · Other:业务板 |
State |
单板状态: · Stable:单板稳定运行 · Board inserted:单板插入 · Kernel initiating:单板内核初始化 · Service starting:单板上的服务正在启动 · Service stopping:单板上的服务正在关闭 · HA Batch backup:HA批量备份中 · Interface data batch backup:接口管理批量备份未完成 · MDC starting:MDC正在启动 · MDC stopping:MDC正在关闭 |
* |
当前对象处于未稳定状态 |
【相关命令】
· display device
· display ha service-group(可靠性命令参考/进程分布优化)
· display mdc(虚拟化技术命令参考/MDC)
display transceiver alarm命令用来显示可插拔接口模块的当前故障告警信息。
【命令】
display transceiver alarm interface [ interface-type interface-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
interface [ interface-type interface-number ]:显示接口上插入的可插拔接口模块的当前故障告警信息。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
【使用指导】
目前,使用的可插拔接口模块可能出现的故障告警信息见“display transceiver alarm命令输出信息描述表”。如果没有故障,则显示为None。
表1-28 SFP/SFP+的display transceiver alarm命令输出信息描述表
字段 |
描述 |
RX signal loss |
接收信号丢失 |
RX power high alarm |
接收光功率高告警 |
RX power high warning |
接收光功率高预警 |
RX power low alarm |
接收光功率低告警 |
RX power low warning |
接收光功率低预警 |
TX fault |
发送错误 |
TX bias high alarm |
偏置电流高告警 |
TX bias high warning |
偏置电流高预警 |
TX bias low alarm |
偏置电流低告警 |
TX power high warning |
发送光功率高预警 |
TX power high alarm |
发送光功率高告警 |
TX power high warning |
发送光功率高预警 |
TX power low alarm |
发送光功率低告警 |
TX power low warning |
发送光功率低预警 |
Temp high alarm |
温度高告警 |
Temp high warning |
温度高预警 |
Temp low alarm |
温度低告警 |
Temp low warning |
温度低预警 |
Voltage high alarm |
电压高告警 |
Voltage high warning |
电压高预警 |
Voltage low alarm |
电压低告警 |
Voltage low warning |
电压低预警 |
Transceiver info I/O error |
模块信息读写错误 |
Transceiver info checksum error |
模块信息校验和错误 |
Transceiver type and port configuration mismatch |
模块类型和端口配置不匹配 |
Transceiver type not supported by port hardware |
端口不支持该模块类型 |
Received an ITU channel number request |
收到ITU通道编号申请。仅CFP2-200G-DCO-Tunable光模块支持显示该信息 |
RX CDR loss of lock |
接收侧CDR失锁,表示信号不好 |
TX CDR loss of lock |
发送侧CDR失锁,表示信号不好 |
表1-29 QSFP+/QSFP28的display transceiver alarm命令输出信息描述表
字段 |
描述 |
Temp high alarm |
温度高告警 |
Temp high warning |
温度高预警 |
Temp low alarm |
温度低告警 |
Temp low warning |
温度低预警 |
Voltage high alarm |
电压高告警 |
Voltage high warning |
电压高预警 |
Voltage low alarm |
电压低告警 |
Voltage low warning |
电压低预警 |
RX loss of signal(channel x) |
通道x接收到的信号丢失 |
TX fault(channel x) |
通道x发送报文时出错 |
TX loss of signal(channel x) |
通道x发送的信号丢失 |
RX power high(channel x) |
通道x接收到的光的功率太高 |
RX power low(channel x) |
通道x接收到的光的功率太低 |
TX power high alarm(channel x) |
通道x发送光功率高告警 |
TX power high warning(channel x) |
通道x发送光功率高预警 |
TX power low alarm(channel x) |
通道x发送光功率低告警 |
TX power low warning(channel x) |
通道x发送光功率低预警 |
TX bias high(channel x) |
通道x的偏置电流高 |
TX bias low(channel x) |
通道x的偏置电流低 |
Transceiver info I/O error |
模块读写错误 |
Transceiver info checksum error |
模块信息校验和错误 |
Transceiver type and port configuration mismatched |
模块类型和端口配置不匹配 |
Transceiver type not supported |
端口不支持该类型的模块 |
表1-30 XFP的display transceiver alarm命令输出信息描述表
字段 |
描述 |
RX signal loss |
接收信号丢失 |
RX not ready |
接收状态未就绪 |
RX CDR loss of lock |
RX CDR时钟失锁 |
RX power high alarm |
接收光功率高告警 |
RX power high warning |
接收光功率高预警 |
RX power low alarm |
接收光功率低告警 |
RX power low warning |
接收光功率低预警 |
TX not ready |
发送状态未就绪 |
TX fault |
发送错误 |
TX CDR loss of lock |
TX CDR时钟失锁 |
TX bias high alarm |
偏置电流高告警 |
TX bias high warning |
偏置电流高预警 |
TX bias low alarm |
偏置电流低告警 |
TX bias low warning |
偏置电流低预警 |
TX power high alarm |
发送光功率高告警 |
TX power high warning |
发送光功率高预警 |
TX power low alarm |
发送光功率低告警 |
TX power low warning |
发送光功率低预警 |
Module not ready |
模块状态未就绪 |
APD supply fault |
APD(Avalanche Photo Diode,雪崩光电二极管)错误 |
TEC fault |
TEC(Thermoelectric Cooler,热点冷却器)错误 |
Wavelength unlocked |
光信号波长失锁 |
Temp high alarm |
温度高告警 |
Temp high warning |
温度高预警 |
Temp low alarm |
温度低告警 |
Temp low warning |
温度低预警 |
Voltage high alarm(3.3V) |
电压高告警(3.3V) |
Voltage high warning(3.3V) |
电压高预警(3.3V) |
Voltage low alarm(3.3V) |
电压低告警(3.3V) |
Voltage low warning(3.3V) |
电压低预警(3.3V) |
Voltage high alarm(5.5V) |
电压高告警(5.5V) |
Voltage high warning(5.5V) |
电压高预警(5.5V) |
Voltage low alarm(5.5V) |
电压低告警(5.5V) |
Voltage low warning(5.5V) |
电压低预警(5.5V) |
Voltage high alarm(1.8V) |
电压高告警(1.8V) |
Voltage high warning(1.8V) |
电压高预警(1.8V) |
Voltage low alarm(1.8V) |
电压低告警(1.8V) |
Voltage low warning(1.8V) |
电压低预警(1.8V) |
Voltage high alarm(5.2V) |
电压高告警(5.2V) |
Voltage high warning(5.2V) |
电压高预警(5.2V) |
Voltage low alarm(5.2V) |
电压低告警(5.2V) |
Voltage low warning(5.2V) |
电压低预警(5.2V) |
Transceiver info I/O error |
模块信息读写错误 |
Transceiver info checksum error |
模块信息校验错误 |
Transceiver type and port configuration mismatch |
模块类型和端口配置不匹配 |
Transceiver type not supported by port hardware |
端口不支持该模块类型 |
【举例】
# 显示接口GigabitEthernet1/2/0/1上插入的可插拔接口模块的当前故障告警信息。
<Sysname> display transceiver alarm interface gigabitethernet 1/2/0/1
GigabitEthernet1/2/0/1 transceiver current alarm information:
RX signal loss
RX power low
表1-31 display transceiver alarm显示信息描述表
字段 |
描述 |
transceiver current alarm information |
接口光模块当前故障告警信息 |
RX signal loss |
接收信号丢失 |
RX power low |
接收光功率低告警 |
display transceiver brief命令用来一键式显示设备所有可插拔接口模块的类型和收发功率等信息。
【命令】
display transceiver brief
【视图】
任意视图
【缺省用户角色】
network-admin
mdc-admin
【举例】
# 显示设备所有可插拔接口模块的类型和收发功率。
<Sysname> display transceiver brief
Interface TransceiverType WaveL(nm) Mode Rx(dBm) Tx(dBm) Status
Current/Range Current/Range
GE1/2/0/1 10G-10km-QSFPDD 1310 SM -15.0/[-18.5,-3.0] -15.0/[-18.5,-3.0] Normal
GE1/2/0/2 10G-10km-QSFPDD 1310 SM -15.0/[-18.5,-3.0] -29.0/[-18.5,-3.0] Beyond threshold
GE1/2/0/3 10G-10km-QSFPDD 1310 SM NA/[-18.5,-3.0] NA/[-18.5,-3.0] Unknown
GE1/2/0/3 10G-10km-QSFPDD -- -- -- -- --
GE1/2/0/3 -- -- -- -- -- --
GE1/2/0/4 100G-10km-QSFPDD 1310 SM -15.0/[-18.5,-3.0] -29.0/[-18.5,-3.0] Normal
-15.0/[-18.5,-3.0] -29.0/[-18.5,-3.0] Normal
-15.0/[-18.5,-3.0] -29.0/[-18.5,-3.0] Normal
表1-32 display transceiver brief命令显示信息描述表
字段 |
说明 |
Interface |
接口简称 |
Type |
可插拔接口模块的类型,由速率、传输距离、类型拼接,"--"表示数据获取失败或者不支持 |
WaveL |
接口的波长,"--"表示数据获取失败或者不支持 |
Mode |
可插拔接口模块的模式,取值为: · SM:表示单模(Single Mode) · --:表示数据获取失败或者不支持 |
Rx(dBm) Current/Range |
当前输入功率/输入功率的正常范围,"--"表示数据获取失败或者不支持,"N/A"表示获取功率值无效 |
Tx(dBm) Current/Range |
当前输出功率/输出功率的正常范围,"--"表示数据获取失败或者不支持,"N/A"表示获取功率值无效 |
Status |
当前功率的状态。取值为: · Normal:表示功率处于正常范围 · Beyond threshold:表示功率超出正常范围 · Unknown:表示未知状态 · --:表示数据获取失败或者不支持 |
display transceiver diagnosis命令用来显示可插拔光模块的数字诊断参数的当前测量值。
【命令】
display transceiver diagnosis interface [ interface-type interface-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
interface [ interface-type interface-number ]:显示接口上插入的可插拔光模块的数字诊断参数的当前测量值。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
【举例】
# 显示接口GigabitEthernet1/2/0/1上插入的可插拔光模块的数字诊断参数的当前测量值。
<Sysname> display transceiver diagnosis interface gigabitethernet 1/2/0/1
GigabitEthernet1/2/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
36 3.31 6.13 -35.64 -5.19
Alarm thresholds:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
High 50 3.55 1.44 -10.00 5.00
Low 30 3.01 1.01 -30.00 0.00
Warning thresholds:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
High 45 3.25 1.25 -15.00 4.00
Low 25 2.85 0.85 -25.00 1.00
# 显示接口HundredGigE1/2/0/1上插入的可插拔光模块的数字诊断参数的当前测量值。
<Sysname> display transceiver diagnosis interface hundredgige 1/2/0/1
HundredGigE1/2/0/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
36 3.31 6.13 -35.64 -5.19
Alarm thresholds:
Temp(℃) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
High 50 3.55 1.44 -10.00 5.00
Low 30 3.01 1.01 -30.00 0.00
Optical statistics over PM interval:
Parameter Current Average Min Max
TX Power(dBm) 0 0 -1 1
RX Power(dBm) 0 0 -1 1
Chromatic Dispersion(ps/nm) 3 3 1 5
Differential Group Delay(ps) 1 1 0 2
Q(dB) 0.5 0.3 0.2 0.4
Carrier Frequency(MHz) 200 300 50 500
SNR(dB) 12 15 10 16
SNR of X Polarization(dB) 13.7 N/A N/A N/A
SNR of Y Polarization (dB) 14.5 N/A N/A N/A
BER 6.00E-07 5.00E-07 3.00E-07 1.00E-08
OSNR(dB) 12 15 10 16
OSNR of X Polarization(dB) 13.7 N/A N/A N/A
OSNR of Y Polarization (dB) 14.5 N/A N/A N/A
表1-33 display transceiver diagnosis显示信息描述表
字段 |
描述 |
transceiver diagnostic information |
接口插入的光模块的数字诊断信息 |
Current diagnostic parameters |
当前的诊断参数 |
Wave.er(nm) |
波长偏移,单位为nm,精确到0.001nm。仅CFP2-200G-DCO-Tunable光模块支持显示该字段 |
Freq.er(GHz) |
频率偏移,单位为GHZ,精确到0.1GHZ。仅CFP2-200G-DCO-Tunable光模块支持显示该字段 |
Temp.(°C) |
数字诊断参数——温度,单位为°C,精确到1°C |
Voltage(V) |
数字诊断参数——电压,单位为V,精确到0.01V |
Total RX power(dBm) |
数字诊断参数——总接收光功率,单位为dBm,精确到0.01dBm |
Total TX power(dBm) |
数字诊断参数——总发送光功率,单位为dBm,精确到0.01dBm |
Bias(mA) |
数字诊断参数——偏置电流,单位为mA,精确到0.01mA |
RX power(dBm) |
数字诊断参数——接收光功率,单位为dBm,精确到0.01dBm |
TX power(dBm) |
数字诊断参数——发送光功率,单位为dBm,精确到0.01dBm |
Alarm thresholds |
告警门限 |
High |
高告警门限或高预警门限 |
Low |
低告警门限或高预警门限 |
Warning threshold |
预警门限 |
Total average launch power(dBm) |
针对多通道光模块的各通道发射总功率,单位为mBM,精确到0.01dBm |
表1-34 display transceiver diagnosis显示信息中光学参数统计信息描述表(本表中的显示信息仅CFP2-200G-DCO-Tunable光模块支持)
字段 |
描述 |
Optical statistics over PM interval |
当前性能监控间隔时间内的光学参数统计信息 |
Parameter Current Average Min Max |
参数名称、参数的当前值、平均值、最小值、最大值 |
TX power(dBm) |
数字诊断参数——发送光功率,单位为dBm,精确到0.01dBm |
RX power(dBm) |
数字诊断参数——接收光功率,单位为dBm,精确到0.01dBm |
Chromatic dispersion(ps/nm) |
数字诊断参数——色散,单位为ps/nm,精确到1ps/nm |
Differential group delay(ps) |
数字诊断参数——差分群时延,单位为ps,精确到1ps |
Q(dB) |
数字诊断参数——Q因子,单位为dB,精确到0.1dB |
Carrier frequency(MHz) |
数字诊断参数——载波频率偏移,单位为MHz,精确到1MHz |
SNR(dB) |
数字诊断参数——电信噪比,单位为dB,精确到0.1dB |
SNR of X polarization(dB) |
数字诊断参数——X偏振态电信噪比,单位为dB,精确到0.1dB |
SNR of Y polarization (dB) |
数字诊断参数——Y偏振态电信噪比,单位为dB,精确到0.1dB |
BER |
数字诊断参数——误码率,科学技术法表示,尾数精确到小数点后2位 |
OSNR(dB) |
数字诊断参数——光信噪比,单位为dB,精确到0.1dB |
OSNR of X polarization(dB) |
数字诊断参数——X偏振态光信噪比,单位为dB,精确到0.1dB |
OSNR of Y polarization (dB) |
数字诊断参数——Y偏振态光信噪比,单位为dB,精确到0.1dB |
display transceiver interface命令用来显示可插拔接口模块的主要特征参数。
【命令】
display transceiver interface [ interface-type interface-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
interface-type interface-number:显示接口上插入的可插拔接口模块的主要特征参数。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
【举例】
# 显示接口GigabitEthernet1/2/0/1上插入的可插拔接口模块的主要特征参数。
<Sysname> display transceiver interface gigabitethernet 1/2/0/1
GigabitEthernet1/2/0/1 transceiver information:
Transceiver Type : 1000_BASE_SX_SFP
Connector Type : LC
Wavelength(nm) : 850
Transfer Distance(m) : 550(50um),275(62.5um)
Digital Diagnostic Monitoring : YES
Vendor Name : H3C
表1-35 display transceiver interface命令显示信息描述表
字段 |
描述 |
transceiver information |
可插拔接口模块信息 |
Transceiver Type |
可插拔接口模块的物理型号 |
Connector Type |
可插拔接口模块的连接器类型,其中: · 光纤连接器包括SC(SC Connector,NTT公司推出的拔插锁紧式光纤连接器)、LC(LC Connector,Lucent公司推出的1.25mm/RJ45锁紧式光纤连接器)两种类型 · 其他连接器包括RJ-45、CX4等类型 |
Wavelength(nm) |
· 光模块:显示发送激光中心波长,单位nm;对于支持多条不同波长光路的模块(例如10GBASE-LX4模块),各个波长值之间用逗号分隔 · 电模块:显示为“N/A” |
Transfer Distance(xx) |
传输距离,xx为传输距离的单位,对于单模模块xx为km,对于其他模块xx为m。当模块支持多种传输介质时,各个传输距离值之间用逗号分隔。距离值后面括号里包含对应的“传输介质”。下面是各个介质的名称: · 9um:表示9/125um单模光纤 · 50um:表示50/125um OM2多模光纤 · 62.5um:表示62.5/125um OM1多模光纤 · CX4:表示CX4电缆 · OM3:表示50um OM3多模光纤 · OM4:表示50um OM4多模光纤 · OM5:表示50um OM5多模光纤 · STACK:表示堆叠线 · TP:表示双绞线 |
Digital Diagnostic Monitoring |
对数字诊断功能的支持情况,其中: · YES:表示支持数字诊断 · NO:表示不支持数字诊断 |
Vendor Name |
模块生产或定制厂商名称 |
display transceiver itu-channel命令用来显示光模块的ITU通道信息。
【命令】
display transceiver itu-channel interface [ interface-type interface-number [ supported-channel ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
interface:显示接口上插入的光模块当前使用的ITU通道的信息。
interface-type interface-number:显示指定光模块当前使用的ITU通道的信息。interface-type interface-number表示接口类型和接口编号。不指定该参数时,表示所有接口上光模块当前使用的ITU通道的信息。
supported-channel:仅显示接口支持配置的ITU通道的信息。不指定该参数时,仅显示光模块当前使用的ITU通道的信息。
【使用指导】
本命令仅CFP2-200G-DCO-Tunable光模块支持。
仅CR-HIC-CC01子卡的100G接口支持CFP2-200G-DCO-Tunable光模块。
【举例】
# 显示HundredGigE1/2/0/1上插入的光模块当前使用的ITU通道的信息。
<Sysname> display transceiver itu-channel interface hundredgige 1/2/0/1
Interface Channel WaveLength(nm) Frequency(THz)
HGE1/2/0/1 1 1566.72 191.35
# 显示HundredGigE1/2/0/1上插入的光模块支持配置的ITU通道的信息。
<Sysname> display transceiver itu-channel interface hundredgige 1/2/0/1 supported-channel
ITU channel settings supported on HundredGigE1/2/0/1 :
Channel WaveLength(nm) Frequency(THz)
1 1566.72 191.35
2 1566.31 191.40
3 1565.90 191.45
4 1565.50 191.50
5 1565.09 191.55
6 1564.68 191.60
7 1564.27 191.65
8 1563.86 191.70
其它显示信息略……。
表1-36 display transceiver itu-channel interface命令显示信息描述表
字段 |
描述 |
Interface |
光模块所在接口的简称 |
Channel |
ITU通道编号 |
WaveLength(nm) |
通道编号对应的波长,单位为nm,精确到0.01nm。取值为“-”时,表示对应接口显示ITU通道信息失败,失败原因有: · 该接口上未插入光模块 · 该接口上光模块不支持配置ITU通道编号 · 光模块获取ITU通道信息失败 · 设备不支持光模块上当前存储的ITU通道编号 |
Frequency(THz) |
通道编号对应的频率,单位为THZ,精确到0.01THZ。取值为“-”时,表示对应接口显示ITU通道信息失败,失败原因有: · 该接口上未插入光模块 · 该接口上光模块不支持配置ITU通道编号 · 光模块获取ITU通道信息失败 · 设备不支持光模块上当前存储的ITU通道编号 |
【相关命令】
· itu-channel
display transceiver manuinfo命令用于显示可插拔接口模块的电子标签信息。
【命令】
display transceiver manuinfo interface [ interface-type interface-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
interface [ interface-type interface-number ]:显示接口上插入的可插拔接口模块的部分电子标签信息。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。
【举例】
# 显示接口GigabitEthernet1/2/0/1上插入的可插拔接口模块的电子标签信息。
<Sysname> display transceiver manuinfo interface gigabitethernet 1/2/0/1
GigabitEthernet1/2/0/1 transceiver manufacture information:
Manu. Serial Number : 213410A0000054000251
Manufacturing Date : 2012-09-01
Vendor Name : H3C
表1-37 display transceiver manuinfo命令显示信息描述表
字段 |
描述 |
Manu. Serial Number |
在生产过程中生成的序列号 |
Manufacturing Date |
写入电子标签的日期 |
Vendor Name |
厂商名称 |
display transceiver optics interface命令用来显示可插拔光模块的主要光学参数。
【命令】
display transceiver optics interface [ interface-type interface-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【参数】
interface-type interface-number:显示接口上插入的光模块的主要光学参数。interface-type interface-number表示接口类型和接口编号。不指定该参数时,表示所有支持配置光学参数的接口。
【使用指导】
本命令仅CFP2-200G-DCO-Tunable光模块支持。
仅CR-HIC-CC01子卡的100G接口支持CFP2-200G-DCO-Tunable光模块。
【举例】
# 显示接口HundredGigE1/2/0/1上插入的可插拔接口模块的主要特征参数。
<Sysname> display transceiver optics interface hundredgige 1/2/0/1
HundredGigE1/2/0/1 transceiver optics information:
Modulation mode : Non-diff 15% SD-FEC DP-8QAM Denali Compatible
Grid spacing : 50GHz
Frequency : 194.10THz
Configured transmission power : -5.0dBm
表1-38 display transceiver optics interface命令显示信息描述表
字段 |
描述 |
transceiver optics information |
光模块的主要光学参数 |
Modulation Mode |
调制模式 |
Grid Spacing |
频率间隙 |
Frequency |
工作频率 |
Configued transmission power |
配置的输出光功率 |
【相关命令】
· optics modulation-mode
· optics tx-power
display version命令用来显示系统版本信息。
【命令】
display version
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
mdc-admin
mdc-operator
【举例】
# 查看系统版本信息。
<Sysname> display version
……显示信息略……
display version-update-record命令用来显示启动软件包版本更新操作的记录。
【命令】
display version-update-record
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【使用指导】
仅缺省MDC支持本命令。
设备启动时会记录当前使用的启动软件包版本信息,如果在运行过程中进行启动软件包版本更新操作,系统会记录该次更新的简要信息,包括升级时间和版本,以便管理员了解相关信息。设备重启这些记录也不会被删除。
【举例】
# 显示设备启动软件包版本更新操作的记录。
<Sysname> display version-update-record
Record 1 (updated on Apr 18 2014 at 06:23:54):
*Name : boot-test.bin
Version : 7.1.053 Alpha 7153
Compile time: Mar 25 2014 15:52:43
*Name : system-test.bin
Version : 7.1.053 Alpha 7153
Compile time: Mar 25 2014 15:52:43
表1-39 display version-update-record命令显示信息描述表
字段 |
描述 |
Record n (updated on Apr 18 2014 at 06:23:54) |
最近的第n次更新的时间,Record 1为最新的一次更新 |
*Name |
软件包的名称。带*符号,表示软件包的版本和升级前的版本有变化;不带*符号,表示版本没有变化 |
Version |
软件包的版本号 |
Compile time |
版本编译时间 |
【相关命令】
· reset version-update-record
display voltage命令用来显示设备上电压传感器的电压信息。
【命令】
display voltage [ chassis chassis-number [ slot slot-number ] ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
chassis chassis-number:显示集群中指定成员设备上电压传感器的电压信息。chassis-number表示设备在集群中的成员编号。
slot slot-number:显示设备中指定单板上的电压传感器的电压信息。slot-number表示单板所在的槽位号。
【使用指导】
仅缺省MDC支持本命令。
不指定chassis参数时,显示的是集群中所有电压传感器的电压信息;指定chassis但不指定slot参数时,显示的是指定成员设备上所有电压传感器的电压信息。
如果电压低于低压告警门限或者高于高压告警门限,系统会生成日志信息和告警信息提示用户。
【举例】
# 显示设备上所有电压传感器的电压信息。
<Sysname> display voltage
System voltage information (volt):
------------------------------------------------------------------------------
Slot Sensor Voltage Status Required LowLimit HighLimit Description
1/8 1 3.320 Normal 3.300 2.967 3.626 3.30
1/8 2 5.079 Normal 5.000 4.498 5.497 5.00
1/8 3 1.860 Normal 1.800 1.618 1.978 1.80
1/8 4 1.514 Normal 1.500 1.348 1.649 1.50
1/8 5 12.022 Normal 12.000 10.797 13.195 12.00
1/8 6 0.932 Normal 0.900 0.810 0.990 0.90
1/8 7 1.203 Normal 1.200 1.080 1.320 1.20
1/8 8 1.009 Normal 1.000 0.900 1.100 1.00
1/8 9 1.026 Normal 1.000 0.900 1.100 1.00
1/8 10 1.280 Normal 1.250 1.125 1.375 1.25
表1-40 display voltage命令显示信息描述表
字段 |
描述 |
System voltage information (volt) |
系统电压信息 |
Slot |
机框编号/槽位编号。当显示数字时表示指定slot上电压传感器的电压信息 |
Sensor |
电压传感器的编号 |
Voltage |
电压传感器的当前电压值 |
Status |
电压传感器的状态 |
Required |
电压传感器的额定电压 |
LowLimit |
电压传感器的低压告警门限 |
HighLimit |
电压传感器的高压告警门限 |
Description |
电压传感器的描述信息,由设备自动生成,用额定电压值表示。如果多个电压传感器的额定电压值相同时,会在额定电压前面添加字符串以示区别 |
fan auto-control-mode命令用来配置风扇的工作模式。
undo fan auto-control-mode命令用来恢复缺省情况。
【命令】
fan auto-control-mode chassis chassis-number { low-temperature | silence }
undo fan auto-control-mode chassis chassis-number
【缺省情况】
风扇工作在静音模式。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
low-temperature:配置风扇工作在低温模式。该模式下风扇转速较高,以便优先保证单板在较低的温度下工作。
silence:配置设备工作在静音模式。该模式下风扇转速较低、噪音较小,但是单板温度比低温模式略高。在对噪音比较敏感的场合推荐使用此模式。
【举例】
# 配置风扇工作在静音模式。
<Sysname> system-view
[Sysname] fan auto-control-mode silence
hardware-failure-detection命令用来配置当系统检测到硬件故障时自动采取的修复操作。
undo hardware-failure-detection命令用来恢复缺省情况。
【命令】
hardware-failure-detection { board | chip | forwarding } { isolate | off | reset | warning }
undo hardware-failure-detection { board | chip | forwarding }
【缺省情况】
当系统检测到器件(chip)、单板(board)和转发(forwarding)的硬件故障时,修复操作均为warning。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
board:对单板故障进行在线检测,包括控制通道检测和单板状态快速检测。
chip:对器件故障进行在线检测,包括单板上各种器件(比如芯片、电容、电阻等)的检测。
forwarding:对转发层面的故障进行在线检测,包括业务自动检测和其他转发相关的检测。
isolate:检测到故障时,设备会自动关闭端口、隔离单板、禁止单板加载或给单板下电,从而尽量减小故障的影响。
off:检测到故障时,设备不进行任何操作。
reset:检测到故障时,设备会自动重启器件/单板以尝试修复故障。
warning:检测到故障时,设备发送Trap信息,不会修复故障。
【使用指导】
仅缺省MDC支持本命令。
设备启动后,系统会持续自动检测器件、单板和转发的硬件故障。
【举例】
# 配置系统检测到器件故障时自动告警。
<Sysname> system-view
[Sysname] hardware-failure-detection chip warning
hardware-failure-protection aggregation命令用来开启针对聚合组的硬件故障保护功能。
undo hardware-failure-protection aggregation命令用来关闭针对聚合组的硬件故障保护功能。
【命令】
hardware-failure-protection aggregation
undo hardware-failure-protection aggregation
【缺省情况】
针对聚合组的硬件故障保护功能处于关闭状态。
【视图】
系统视图
【缺省用户角色】
network-admin
【使用指导】
仅缺省MDC支持本命令。
只有配置hardware-failure-detection forwarding isolate命令后,该命令才生效。
配置该命令后,当系统检测到硬件故障时,会按顺序遵循如下原则处理:
· 如果聚合组成员端口配置undo hardware-failure-protection auto-down命令,而且该端口不是聚合组中最后一个UP状态的端口,则该端口会被自动关闭;
· 如果聚合组成员端口配置undo hardware-failure-protection auto-down命令,而该端口是聚合组中最后一个UP状态的端口,则该端口不会被关闭;
· 如果聚合组成员端口配置了hardware-failure-protection auto-down命令,则不管该端口是不是聚合组中最后一个UP状态的端口,该端口都会被关闭。
出现以下任意一种情况时,hardware-failure-protection aggregation命令会对聚合组中的该成员端口失效:
· 端口下配置了以太网接口环回测试功能,即loopback { external | internal }命令;
· 端口下配置了以太网接口的强制开启功能,即port up-mode命令;
· 该端口配置为集群物理端口。
【举例】
# 开启针对聚合组的硬件故障保护功能。
<Sysname> system-view
[Sysname] hardware-failure-protection aggregation
【相关命令】
· hardware-failure-detection
· hardware-failure-protection auto-down
hardware-failure-protection auto-down命令用来开启针对端口的硬件故障保护功能。
undo hardware-failure-protection auto-down命令用来关闭针对端口的硬件故障保护功能。
【命令】
hardware-failure-protection auto-down
undo hardware-failure-protection auto-down
【缺省情况】
针对端口的硬件故障保护功能处于开启状态。
【视图】
以太网接口视图
【缺省用户角色】
network-admin
mdc-admin
【使用指导】
在端口上配置该命令前,请确保该端口存在备份的链路,以免造成业务中断。
在端口上配置hardware-failure-protection auto-down命令后,当系统检测到硬件故障时,会自动关闭该端口。此时使用display interface命令可看到该端口状态为Protect DOWN。端口硬件故障解除后,请在接口下执行undo shutdown命令来恢复端口状态。
配置了hardware-failure-detection forwarding isolate后,本命令才会生效。
出现以下任意一种情况时,hardware-failure-protection auto-down命令会对该端口失效:
· 端口下配置了以太网接口环回测试功能,即loopback { external | internal }命令;
· 端口下配置了以太网接口的强制开启功能,即port up-mode命令;
· 该端口配置为集群物理端口。
【举例】
# 对端口配置硬件故障保护。
<Sysname> system-view
[Sysname] interface gigabitethernet 1/2/0/1
[Sysname-GigabitEthernet1/2/0/1] hardware-failure-protection auto-down
header命令用来配置欢迎信息。
undo header命令用来取消配置的欢迎信息。
【命令】
header { legal | login | motd | shell } text
undo header { legal | login | motd | shell }
【缺省情况】
未配置欢迎信息。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
legal:配置登录终端界面前的授权信息,在输入认证用户名和密码前输出。
login:配置登录验证时的欢迎信息。
motd:配置登录终端界面前的欢迎信息。
shell:配置用户登录进入用户视图时的欢迎信息。
text:欢迎信息的内容。内容的输入支持单行和多行两种方式,具体输入规则请参见“基础配置指导”中的“设备管理”。
【举例】
# 配置legal欢迎信息。
<Sysname> system-view
[Sysname] header legal
Please input banner content, and quit with the character '%'.
Welcome to use the legal banner%
itu-channel命令用来配置光模块的ITU通道编号。
undo itu-channel命令用来恢复缺省情况。
【命令】
itu-channel channel-number
undo itu-channel
【缺省情况】
光模块的ITU通道编号为1。
【视图】
以太网接口视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
channel-number:表示光模块的ITU通道编号。
【使用指导】
本命令仅CFP2-200G-DCO-Tunable光模块支持。
仅CR-HIC-CC01子卡的100G接口支持CFP2-200G-DCO-Tunable光模块。
【举例】
# 将HundredGigE1/2/0/1上插入的光模块的ITU通道编号配置为2。
<Sysname> system-view
[Sysname] interface hundredgige 1/2/0/1
[Sysname-HundredGigE1/2/0/1] itu-channel 2
Changing the channel number causes the service to be down for a while. Continue? [Y/N]:Y
【相关命令】
· display transceiver itu-channel
job命令用来为Schedule分配Job。
undo job命令用来将Job从Schedule中删除。
【命令】
job job-name
undo job job-name
【缺省情况】
未为Schedule分配Job。
【视图】
Schedule视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
job-name:Job的名称,为1~47个字符的字符串,区分大小写。
【使用指导】
多次执行该命令,可以为Schedule分配多个Job。多个Job在Schedule指定的时间同时执行,没有先后顺序。
分配的Job必须是设备上已经创建的Job,否则不能分配。Job可以通过scheduler job命令来创建。
【举例】
# 为Schedule分配一个名称为save-job的Job。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] job save-job
【相关命令】
· scheduler job
· scheduler schedule
memory-threshold命令用来配置空闲内存告警的门限值。
undo memory-threshold命令用来恢复缺省情况。
【命令】
memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] [ ratio ] minor minor-value severe severe-value critical critical-value normal normal-value [ early-warning early-warning-value secure secure-value ]
undo memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
一级告警门限为1912M,二级告警门限为1274M,三级告警门限为637M,系统内存恢复正常状态时的内存大小为2549M,预告警门限为3187M,预告警恢复门限为3824M。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
ratio:表示以百分比形式配置门限。不指定该参数时,表示配置的是门限的大小,单位为MB。
minor minor-value:一级告警门限,单位为兆字节(MB),输入该参数的值时可通过输入?,来获取该参数的取值范围;minor-value应小于等于normal-value;为0则表示关闭该级门限告警功能。
severe severe-value:二级告警门限,单位为兆字节(MB),输入该参数的值时可通过输入?,来获取该参数的取值范围;severe-value必须小于等于minor-value;为0则表示关闭该级门限告警功能。
critical critical-value:三级告警门限,单位为兆字节(MB),输入该参数的值时可通过输入?,来获取该参数的取值范围;critical-value必须小于等于severe-value;为0则表示关闭该级门限告警功能。
normal normal-value:系统内存恢复正常状态时的内存大小,单位为兆字节(MB),输入该参数的值时可通过输入?,来获取该参数的取值范围;normal-value必须小于等于实际内存大小。
early-warning early-warning-value:预告警门限。输入该参数的值时可通过输入?,来获取该参数的取值范围。取值为0时,表示关闭该级别的告警功能。缺省预告警门限为3187M。
secure secure-value:预告警恢复门限。输入该参数的值时可通过输入?,来获取该参数的取值范围。缺省预告警恢复门限为3824M。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU编号。
【使用指导】
仅缺省MDC支持本命令。
系统实时监控剩余空闲内存大小,当条件达到时,就产生相应的告警/告警解除通知,以便通知关联的业务模块/进程采取相应的措施,以便最大限度的利用内存,又能保证设备的正常运行。
设备监控的是系统内存中剩余空闲内存的大小,使用display memory命令可以查看系统内存的使用情况。
关于告警门限的详细介绍请参见“基础配置指导”中的“设备管理”。
【举例】
# 配置一级、二级、三级告警门限分别为64MB、48MB、32MB,当剩余空闲内存大于96MB时,恢复到正常状态。
<Sysname> system-view
[Sysname] memory-threshold minor 64 severe 48 critical 32 normal 96
【相关命令】
· display memory-threshold
memory-threshold dma命令用来配置DMA(Direct Memory Access,直接内存存取)内存告警阈值。
undo memory-threshold dma命令用来恢复缺省情况。
【命令】
memory-threshold dma [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] [ ratio ] critical critical-value normal normal-value
undo memory-threshold dma [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
DMA内存告警阈值为2048KB,告警恢复阈值为4096KB。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
ratio:以百分比配置阈值。
critical critical-value:告警阈值。当指定ratio参数时,critical-value为百分比,取值范围为0~100;当不指定ratio参数时,critical-value单位为KB,取值范围为0~3932160。
normal normal-value:告警恢复阈值。当指定ratio参数时,normal-value为百分比;当不指定ratio参数时,normal-value单位为KB。取值范围为critical-value的配置值~3932160。
【使用指导】
部分业务的运行需要使用DMA内存,如果DMA内存不足,会导致业务模块功能异常。系统周期监控DMA空闲内存大小:当DMA空闲内存小于或等于告警阈值,产生告警事件,表示DMA内存可能不足;当DMA空闲内存大于告警恢复阈值,产生告警解除事件,表示DMA内存充足。
【举例】
# 配置设备的DMA内存告警阈值为32KB,告警恢复阈值为96KB。
<Sysname> system-view
[Sysname] memory-threshold dma critical 32 normal 96
memory-threshold usage命令用来配置内存利用率阈值。
undo memory-threshold usage命令用来恢复缺省情况。
【命令】
memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] usage memory-threshold
undo memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] usage
【缺省情况】
内存利用率阈值为100%。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示全局主用主控板。
cpu cpu-number:表示CPU的编号。
memory-threshold:内存利用率阈值百分比,取值范围为0~100。
【使用指导】
仅缺省MDC支持本命令。
系统每隔1分钟会对内存利用率进行采样,并将采样值和用户配置的内存利用率阈值比较。当采样值大时,则认为内存利用率过高,设备会发送Trap报文。
【举例】
# 配置内存利用率阈值为80%。
<Sysname> system-view
[Sysname] memory-threshold usage 80
【相关命令】
· display memory-threshold
memory-threshold usage resend-interval命令用来配置内存利用率告警的重发间隔。
undo memory-threshold usage resend-interval命令用来恢复缺省情况。
【命令】
memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] usage resend-interval interval-value
undo memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] usage resend-interval
【缺省情况】
内存利用率告警的重发间隔为300秒,即持续300秒超过内存利用率门限则发送一次告警。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
slot slot-number:表示单板所在的槽位号,不指定该参数时,表示主用主控板。
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示全局主用主控板。
cpu cpu-number:表示CPU的编号。
interval-value:表示内存利用率告警发送间隔,取值范围为1~3600,单位为分钟。
【使用指导】
设备定期对内存使用率进行采样,并将采样值与告警门限进行比较。当采样值从小于或等于变成大于某级别告警门限时,进入告警状态并生成告警(日志和Trap)来提醒管理员。如果内存利用率告警的重发间隔到达,内存利用率仍处于告警状态,则再次输出告警。
【举例】
# 配置内存利用率告警的重发间隔为1小时。
<Sysname> system-view
[Sysname] memory-threshold usage resend-interval 60
monitor cpu-usage enable命令用来开启CPU利用率历史记录功能。
undo monitor cpu-usage enable命令用来关闭CPU利用率历史记录功能。
【命令】
monitor cpu-usage enable [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor cpu-usage enable [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
CPU利用率历史记录功能处于开启状态。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示全局主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
开启CPU利用率历史记录功能后,系统会每隔一定时间(可通过monitor cpu-usage interval命令配置)对CPU的利用率进行采样,并把采样结果保存到历史记录区。这些记录可通过display cpu-usage history命令查看,以便用户监控设备近期的运行情况。
【举例】
# 打开CPU利用率历史记录功能。
<Sysname> system-view
[Sysname] monitor cpu-usage enable
【相关命令】
· display cpu-usage configuration
· display cpu-usage history
· monitor cpu-usage interval
monitor cpu-usage interval命令用来配置CPU利用率历史记录的采样周期。
undo monitor cpu-usage interval命令用来恢复缺省情况。
【命令】
monitor cpu-usage interval interval [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor cpu-usage interval [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
CPU利用率历史记录采样周期为1分钟。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
interval:CPU利用率历史记录采用周期,取值为5Sec、1Min或者5Min,不区分大小写。输入该参数时,请完整输入,否则,系统会提示参数错误。
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示全局主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
开启CPU利用率历史记录功能后,系统会每隔一定时间(可通过monitor cpu-usage interval命令配置)对CPU的利用率进行采样,并把采样结果保存到历史记录区。这些记录可通过display cpu-usage history命令查看,以便用户监控设备近期的运行情况。
【举例】
# 配置CPU利用率历史记录的采样周期为5秒。
<Sysname> system-view
[Sysname] monitor cpu-usage interval 5Sec
【相关命令】
· display cpu-usage configuration
· display cpu-usage history
· monitor cpu-usage enable
monitor cpu-usage statistics-interval core命令用来配置CPU核利用率的统计周期。
undo monitor cpu-usage statistics-interval core命令用来恢复缺省情况。
【命令】
monitor cpu-usage statistics-interval interval chassis chassis-number slot slot-number cpu cpu-number core core-id-list
undo monitor cpu-usage statistics-interval chassis chassis-number slot slot-number cpu cpu-number core core-id-list
【缺省情况】
CPU核利用率的统计周期为60秒。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
interval:CPU核利用率信息的统计周期,取值范围为10~3600,单位为秒。配置的统计周期建议是采样周期的整数倍,采样周期是5秒,不是整数倍时,实际生效统计周期为最接近配置值、但小于配置值的、采样周期整数倍。例如,采样周期是5秒,配置统计周期为12秒,则实际生效的统计周期是10秒。
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
cpu cpu-number:表示CPU的编号。
core-id-list:表示CPU核的编号列表。表示方式为core-id-list = { core-id1 [ to core-id2 ] }&<1-10>,core-id2的值要大于或等于core-id1的值,&<1-10>表示前面的参数最多可以重复输入10次。
【使用指导】
系统按5秒周期对CPU核的利用率进行采样,然后对统计周期内的采样值进行计算,并将计算值和用户配置的CPU核利用率的门限比较。当计算值大于门限值时,则认为CPU核利用率过高,设备会发送告警信息并记录日志。
【举例】
# 配置chassis 1 slot 1 cpu 0 core 0利用率的统计周期为60秒。
<Sysname> system-view
[Sysname] monitor cpu-usage statistics-interval 60 chassis 1 slot 1 cpu 0 core 0
【相关命令】
· monitor cpu-usage threshold core
· monitor resend cpu-usage core-interval
monitor cpu-usage threshold命令用来配置CPU利用率告警门限。
undo monitor cpu-usage threshold命令用来恢复缺省情况。
【命令】
monitor cpu-usage threshold cpu-threshold [ minor-threshold minor-threshold recovery-threshold recovery-threshold ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor cpu-usage threshold [ minor-threshold recovery-threshold ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
CPU利用率阈值为99%。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
cpu-threshold:CPU利用率高级别告警门限,取值范围为2~100,单位为百分比。
minor-threshold minor-threshold:CPU利用率低级别告警门限,取值范围为1~“severe-threshold的配置值减1”,单位为百分比。不指定该参数时,该参数的取值为severe-threshold*0.8。
recovery-threshold recovery-threshold:CPU利用率恢复门限,取值范围为0~“minor-threshold的配置值减1”,单位为百分比。不指定该参数时,该参数的取值为severe-threshold*0.7。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
CPU利用率高级别告警门限如果设置过低,可能导致设备提前进入门限状态,不再进行正常业务处理。
系统每隔1分钟会对CPU的利用率进行采样,并将采样值和用户配置的CPU利用率告警门限比较。当采样值大时,则认为CPU利用率过高,设备会发送Trap报文。
当采样值回落,小于等于CPU利用率恢复门限时,则认为CPU利用率已经恢复到正常范围。
【举例】
# 配置CPU利用率高级别告警门限为80%。
<Sysname> system-view
[Sysname] monitor cpu-usage threshold 80
【相关命令】
· display cpu-usage configuration
monitor cpu-usage threshold core命令用来配置CPU核利用率告警门限。
undo monitor cpu-usage threshold core命令用来恢复缺省情况。
【命令】
monitor cpu-usage threshold severe-threshold [ minor-threshold minor-threshold recovery-threshold recovery-threshold ] chassis chassis-number slot slot-number cpu cpu-number core core-id-list
undo monitor cpu-usage threshold [ minor-threshold recovery-threshold ] chassis chassis-number slot slot-number cpu cpu-number core core-id-list
【缺省情况】
没有配置CPU核利用率告警门限
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
severe-threshold:CPU核利用率高级别告警门限,取值范围为2~100,单位为百分比。
minor-threshold minor-threshold:CPU核利用率低级别告警门限,取值范围为1~“severe-threshold的配置值减1”,单位为百分比。不指定该参数时,该参数的取值为severe-threshold*0.8。
recovery-threshold recovery-threshold:CPU核利用率恢复门限,取值范围为0~“minor-threshold的配置值减1”,单位为百分比。不指定该参数时,该参数的取值为severe-threshold*0.7。
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
cpu cpu-number:表示CPU的编号。
core core-id-list:表示CPU核的编号列表。表示方式为core-id-list = { core-id1 [ to core-id2 ] }&<1-10>,core-id2的值要大于或等于core-id1的值,&<1-10>表示前面的参数最多可以重复输入10次。
【使用指导】
系统按5秒周期对CPU核的利用率进行采样,然后对统计周期内的采样值进行计算,并将计算值和用户配置的CPU核利用率的门限比较。当计算值大于门限值时,则认为CPU核利用率过高,设备会发送告警信息并记录日志。
【举例】
# 配置chassis 1 slot 1 cpu 0 core 0的利用率高级别告警门限为90%。
<Sysname> system-view
[Sysname] monitor cpu-usage threshold 90 chassis 1 slot 1 cpu 0 core 0
【相关命令】
· display cpu-usage configuration
· monitor cpu-usage statistics-interval core
monitor disk-usage disk命令用来配置磁盘利用率告警门限。
undo monitor disk-usage disk命令用来恢复缺省情况。
【命令】
monitor disk-usage [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] disk disk-name threshold threshold-value
undo monitor disk-usage [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] disk disk-name threshold
【缺省情况】
磁盘利用率告警门限为90%。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:显示指定CPU的信息。cpu-number表示CPU的编号。只有指定的slot支持多CPU时,才能配置该参数。
disk disk-name:表示磁盘的名称。输入该参数时,请完整输入,需要区分大小写,否则,系统会提示参数错误。
threshold threshold-value:表示磁盘利用率告警门限,为百分比数值,取值范围为1~100。
【使用指导】
配置本命令后,系统会按照指定周期(可通过monitor disk-usage interval命令配置)对磁盘利用率进行采样,并将采样值和用户配置的告警门限比较。当采样值大时,则认为磁盘利用率过高,系统会将磁盘利用率过高事件通知给NETCONF模块。通过NETCONF功能,可以将这个信息反馈给用户。关于NETCONF的详细介绍请参见“网络管理和监控配置指导”中的“NETCONF”。
【举例】
# 配置磁盘利用率告警门限为80%。
<Sysname> system-view
[Sysname] monitor disk-usage disk flash threshold 80
【相关命令】
· monitor disk-usage interval
monitor disk-usage interval命令用来配置磁盘利用率的采样周期。
undo monitor disk-usage interval命令用来恢复缺省情况。
【命令】
monitor disk-usage interval interval
undo monitor disk-usage interval
【缺省情况】
磁盘利用率的采样周期为300秒。
【视图】
系统试图
【缺省用户角色】
network-admin
mdc-admin
【参数】
interval:磁盘利用率的采样周期,取值范围为5~1800,且必须为5的倍数,单位为秒。
【使用指导】
配置本命令后,系统会按照指定周期对磁盘利用率进行采样。
【举例】
# 配置磁盘利用率的采样周期为120秒。
<Sysname> system-view
[Sysname] monitor disk-usage interval 120
【相关命令】
· monitor disk-usage disk
monitor kernel memory fragment interval命令用来配置内核空间的内存分片信息收集周期。
undo monitor kernel memory fragment interval命令用来恢复缺省情况。
【命令】
monitor kernel memory fragment interval interval-value [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor kernel memory fragment interval [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
内核空间的内存分片信息收集周期为5分钟。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
interval-value:内核空间的内存分片信息收集周期,取值范围1~65535,单位为分钟。
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
配置本命令后,设备会按周期收集内核空间的内存分片信息,该信息可以通过命令display kernel memory fragment free、display kernel memory fragment used查看,用于判断内核空间的内存分片的空置率是否正常。
【举例】
# 配置内核空间的内存分片信息收集周期为5分钟。
<Sysname> system-view
[Sysname] monitor kernel memory fragment interval 5
monitor kernel memory fragment ratio命令用来配置内核空间的内存分片空闲率告警阈值。
undo monitor kernel memory fragment ratio命令用来恢复缺省情况。
【命令】
monitor kernel memory fragment ratio ratio-value [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor kernel memory fragment ratio [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
内核空间的内存分片空闲率告警阈值为20%。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
ratio-value:配置内核空间的内存分片空闲率告警阈值,取值范围为1~100。
slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
内核线程运行时,会向系统申请内存,这块内存作为一个整体被申请和释放,就算部分内存块在线程运行过程中,已经被使用过且不再需要使用,也不能提前释放给系统使用,这种空闲但当前不能被使用的内存块也称为内存碎片。使用本命令可以监控内核空间内存碎片占内核空间总内存的比例。当内存碎片的比例大于或等于告警阈值时,表示内核内存的利用率较低,生成告警日志;当内存碎片的比例降低,小于告警阈值时,表示内核内存恢复到正式使用状态,生成告警恢复日志。
【举例】
# 配置内核空间的内存空闲率告警阈值为80。
<Sysname> system-view
[Sysname] monitor kernel memory fragment ratio 80
monitor resend cpu-usage命令用来配置发送CPU告警事件的间隔。
undo monitor resend cpu-usage命令用来取消CPU告警事件发送间隔的配置。
【命令】
monitor resend cpu-usage { minor-interval minor-interval | severe-interval severe-interval } * [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor resend cpu-usage [ minor-interval | severe-interval ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
持续300秒超过低级别告警门限则上报一次CPU低级别告警事件,持续60秒超过高级别告警门限则上报一次CPU高级别告警事件。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
minor-interval minor-interval:CPU低级别告警事件周期发送的间隔,取值范围为10~3600,且只能是5的倍数,单位为秒。
severe-interval severe-interval:CPU高级别告警事件周期发送的间隔,取值范围为10~3600,且只能是5的倍数,单位为秒。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
设备定期对CPU使用率进行采样,并将采样值与告警门限进行比较。当采样值从小于或等于变成大于某级别告警门限时,CPU将进入该级别告警状态并生成相应的告警事件。
CPU处于低级别告警状态时,会周期发送CPU低级别告警事件,直到CPU进入高级别告警状态或者低级别告警状态解除。CPU处于高级别告警状态时,会周期发送CPU高级别告警事件,直到高级别告警状态解除。使用本命令可以修改CPU告警事件的发送周期。
执行undo monitor resend cpu-usage命令不指定minor-interval和severe-interval参数时,表示将这两个参数恢复到缺省情况。当指定某一个参数时,仅将该参数恢复到缺省值。
【举例】
# 配置chassis 1 slot 8 CPU 0低级别告警事件的发送周期为60秒。
<Sysname> system-view
[Sysname] monitor resend cpu-usage minor-interval 60 chassis 1 slot 8 cpu 0
monitor resend cpu-usage core-interval命令用来配置发送CPU核告警事件的间隔。
undo monitor resend cpu-usage core-interval命令用来取消CPU核告警事件发送间隔的配置。
【命令】
monitor resend cpu-usage core-interval { minor-interval minor-interval | severe-interval severe-interval } * [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor resend cpu-usage core-interval [ minor-interval | severe-interval ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
持续300秒超过低级别告警门限则上报一次CPU核低级别告警事件,持续60秒超过高级别告警门限则上报一次CPU核高级别告警事件。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
minor-interval minor-interval:CPU核低级别告警事件周期发送的间隔,取值范围为10~3600,且只能是5的倍数,单位为秒。
severe-interval severe-interval:CPU核高级别告警事件周期发送的间隔,取值范围为10~3600,且只能是5的倍数,单位为秒。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
设备定期对CPU核使用率进行统计,并将统计值与告警门限进行比较。当统计值从小于或等于变成大于告警门限时,CPU核将进入该告警状态并生成告警事件。
CPU核处于告警状态时,会周期发送CPU核告警事件,直到CPU核告警状态解除。使用本命令可以修改CPU核告警事件的发送周期。
【举例】
# 配置设备上所有CPU核发送告警事件的间隔:低级别告警为100秒、高级别告警为60秒。
<Sysname> system-view
[Sysname] monitor resend cpu-usage core-interval minor-interval 100 severe-interval 60
monitor resend memory-threshold命令用来配置发送内存告警事件的间隔。
undo monitor resend memory-threshold命令用来取消内存告警事件发送间隔的配置。
【命令】
monitor resend memory-threshold { critical-interval critical-interval | early-warning-interval early-warning-interval | minor-interval minor-interval | severe-interval severe-interval } * [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor resend memory-threshold [ critical-interval | early-warning-interval | minor-interval | severe-interval ] * [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
持续1小时超过预告警门限则上报一次预告警事件,持续12小时超过一级告警门限则上报一次一级告警事件,持续3小时超过二级告警门限则上报一次二级告警事件,持续1小时超过三级告警门限则上报一次三级告警事件。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
critical-interval critical-interval:内存三级告警事件周期发送的间隔,取值范围1~48,单位为小时。
early-warning-interval early-warning-interval:内存预告警事件周期发送的间隔,取值范围1~48,单位为小时。
minor-interval minor-interval:内存一级告警事件周期发送的间隔,取值范围1~48,单位为小时。
severe-interval severe-interval:内存二级告警事件周期发送的间隔,取值范围1~48,单位为小时。
slot slot-number:表示单板所在的槽位号,不指定该参数时,表示主用主控板。
chassis chassis-number slot slot-number:表示指定成员设备上的指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。不指定该参数时,表示全局主用主控板。
cpu cpu-number:表示CPU的编号。
【使用指导】
设备定期对内存剩余值进行采样,并将采样值与告警门限进行比较。当采样值从大于变成小于或等于某级别告警门限时,内存将进入该级别告警状态并生成相应的告警事件。
内存支持多个级别的告警,这些告警的严重程度从高到低依次为:内存三级告警、内存二级告警、内存一级告警、内存预告警。
内存处于低级别告警状态时,会周期发送内存低级别告警事件,直到设备进入更高级别告警状态或者低级别告警状态解除。内存处于高级别告警状态时,会周期发送内存高级别告警事件,直到高级别告警状态解除。使用本命令可以修改内存告警事件的发送周期。
【举例】
# 配置slot 1 CPU 0内存一级告警事件的发送周期为12小时。
<Sysname> system-view
[Sysname] monitor resend memory-threshold minor-interval 12 slot 1 cpu 0
monitor resend memory-threshold dma命令用来配置发送DMA内存告警事件的间隔。
undo monitor resend memory-threshold dma命令用来恢复缺省情况。
【命令】
monitor resend memory-threshold dma critical-interval critical-interval [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
undo monitor resend memory-threshold dma critical-interval [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
【缺省情况】
DMA内存告警事件周期发送的间隔为300秒。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
critical-interval:DMA内存告警事件周期发送的间隔,取值范围为10~3600,且只能是5的倍数,单位为秒。
chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。
cpu cpu-number:表示CPU编号。
【使用指导】
设备定期对DMA内存使用率进行统计,并将统计值与告警门限进行比较。当统计值从小于或等于变成大于告警门限时,DMA内存将进入该告警状态并生成告警事件。
【举例】
# 配置发送DMA内存告警事件的间隔为100秒。
<Sysname> system-view
[Sysname] monitor resend memory-threshold dma critical-interval 100
optics modulation-mode命令用来配置光模块的调制模式。
undo optics modulation-mode命令用来恢复缺省情况。
【命令】
optics modulation-mode mode
undo optics modulation-mode
【缺省情况】
光模块的调制模式为1。
【视图】
100GE以太网接口视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
mode:表示光模块的调制模式。取值如下:
· 0:该模式下采用的参数为Diff、QPSK、15% SD-FEC Everest Compatible。
· 1:该模式下采用的参数为Non-diff、QPSK、15% SD-FEC Denali Compatible。
· 2:该模式下采用的参数为Non-diff、8QAM、15% SD-FEC Denali Compatible。
· 3:该模式下采用的参数为Non-diff、16QAM、15% SD-FEC Denali Compatible。
【使用指导】
本命令仅CFP2-200G-DCO-Tunable光模块支持。
仅CR-HIC-CC01子卡的100G接口支持CFP2-200G-DCO-Tunable光模块。
配置本命令后,光模块和对端立即重新协商参数,期间,会导致业务短时间中断,请提前做好链路备份工作。
【举例】
# 将HundredGigE1/2/0/1上插入的光模块的调制模式配置为0。
<Sysname> system-view
[Sysname] interface hundredgige 1/2/0/1
[Sysname-HundredGigE1/2/0/1] optics modulation-mode 0
This operation causes the service to be down for a while. Continue? [Y/N]:y
【相关命令】
· display transceiver optics interface
optics tx-power命令用来配置光模块的输出光功率。
undo optics txpower命令用来恢复缺省情况。
【命令】
optics tx-power tx-power
undo optics tx-power
【缺省情况】
光模块的输出光功率为0dBm。
【视图】
100GE以太网接口视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
tx-power:表示光模块的输出光功率,取值范围为浮点数-15.0~1.0dBm,精确到小数点后一位数,单位为dBm。
【使用指导】
本命令仅CFP2-200G-DCO-Tunable光模块支持。
仅CR-HIC-CC01子卡的100G接口支持CFP2-200G-DCO-Tunable光模块。
配置本命令后,光模块和对端立即重新协商参数,期间,会导致业务短时间中断,请提前做好链路备份工作。
【举例】
# 将HundredGigE1/2/0/1上插入的光模块的输出光功率为-14.3dBm。
<Sysname> system-view
[Sysname] interface hundredgige 1/2/0/1
[Sysname-HundredGigE1/2/0/1] optics tx-power -14.3
This operation causes the service to be down for a while. Continue? [Y/N]:Y
【相关命令】
· display transceiver optics interface
password-recovery enable命令用来开启密码恢复功能。
undo password-recovery enable命令用来关闭密码恢复功能。
【命令】
password-recovery enable
undo password-recovery enable
【缺省情况】
密码恢复功能处于开启状态。
【视图】
系统视图
【缺省用户角色】
network-admin
【使用指导】
仅缺省MDC支持本命令。
配置密码恢复功能后,当用户忘记Console口认证密码或者登录认证失败,导致无法使用命令行操作设备时,可通过BootWare菜单清除该认证密码,再继续使用设备;关闭密码恢复功能后,设备将处于一个安全性更高的状态,即当出现上述情况时,若想继续使用Console口对设备进行命令行操作,只能通过BootWare菜单选择将设备恢复为出厂配置之后方可继续操作,这样可以有效地防止非法用户获取启动配置文件。
清除认证密码的操作必须在主用主控板的启动过程中进入BootWare菜单进行。
BootWare菜单中支持配置的选项与密码恢复功能的配置有关,详见设备的版本说明书。
【举例】
# 关闭密码恢复功能。
<Sysname> system-view
[Sysname] undo password-recovery enable
power-supply off命令用来强制给单板断电。
【命令】
power-supply off chassis chassis-number slot slot-number [ subslot subslot-number ]
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number slot slot-number:chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
subslot subslot-number:表示子卡所在的子槽位号。不指定该参数时,表示所有子卡。
【使用指导】
强制给单板下电后,单板将无法收发报文,请谨慎使用。
仅缺省MDC支持本命令。
如果设备电量不足,且某些接口板处于空闲状态或者连接的为非关键网络节点时,可以手工停止给这些接口板供电,以便节约电能保证给重要接口板供电。
请先开启电源管理功能,再配置本命令。否则,本命令配置失败。
【举例】
# 强制给指定slot的单板断电。
<Sysname> power-supply off chassis 1 slot 8
【相关命令】
· power-supply policy enable
power-supply on命令用来手工给单板供电。
【命令】
power-supply on chassis chassis-number slot slot-number [ subslot subslot-number ]
【视图】
用户视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number slot slot-number:chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
subslot subslot-number:表示子卡所在的子槽位号。不指定该参数时,表示所有子卡。
【使用指导】
仅缺省MDC支持本命令。
请先开启电源管理功能,再配置本命令。否则,本命令配置失败。
【举例】
# 手工给指定slot的单板供电。
<Sysname> power-supply on chassis 1 slot 8
【相关命令】
· power-supply policy enable
power-supply policy enable命令用来开启电源管理功能。
undo power-supply policy enable命令用来关闭电源管理功能。
【命令】
power-supply policy chassis chassis-number enable
undo power-supply policy chassis chassis-number enable
【缺省情况】
电源管理功能处于关闭状态。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
【使用指导】
仅缺省MDC支持本命令。
【举例】
# 启用电源管理功能。
<Sysname> system-view
[Sysname] power-supply policy chassis 1 enable
power-supply policy priority命令用来配置单板的供电优先级。
undo power-supply policy priority命令用来恢复缺省情况。
【命令】
power-supply policy chassis chassis-number slot slot-number priority priority
undo power-supply policy chassis chassis-number slot slot-number priority
【缺省情况】
单板的供电优先级为5。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
priority:单板的供电优先级,取值范围为0~9。本参数值越小表示单板的供电优先级越高。
chassis chassis-number slot slot-number:chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
【使用指导】
仅缺省MDC支持本命令。
请根据实际组网应用,将正在处理或将要处理重要业务的单板的优先级值减小,以便在系统供电不足或者电力恢复时,优先保证对该单板的供电。
开启电源管理功能后,本命令才会生效。
【举例】
# 配置指定slot的单板的供电优先级为10。
<Sysname> system-view
[Sysname] power-supply policy chassis 1 slot 2 priority 10
【相关命令】
· power-supply policy enable
power-supply policy redundant命令用来配置冗余电源模块数。
undo power-supply policy redundant命令用来恢复缺省情况。
【命令】
power-supply policy chassis chassis-number redundant module-count
undo power-supply policy chassis chassis-number redundant
【缺省情况】
冗余电源模块数为0。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
module-count:表示冗余电源模块数目,不同型号的设备支持的取值范围不同,用户可以通过帮助信息来获取设备支持的取值范围,但是该范围的上限是系统支持的最大冗余模块数,根据设备安插的接口板的数量和耗电量不同,用户实际能够配置的值会小于等于系统支持的最大冗余模块数。
【使用指导】
仅缺省MDC支持本命令。
只有在开启电源管理功能后,冗余电源配置才会生效。
【举例】
# 配置电源冗余模块数为1。
<Sysname> system-view
[Sysname] power-supply policy chassis 1 redundant 1
【相关命令】
· power-supply policy enable
reboot命令用来重启设备。
【命令】
reboot [ chassis chassis-number [ slot slot-number [ subslot subslot-number ] ] ] [ force ]
【视图】
用户视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
chassis chassis-number:表示设备在集群中的成员编号。不指定该参数时,会重启整个集群。
slot slot-number:表示单板所在的槽位号。不指定该参数时,会重启成员设备。
subslot subslot-number:子卡所在的子槽位号。不指定该参数时,会重启slot。
force:强制重启:
· 不指定该参数时,重启设备,系统会做一些保护性检查(如启动文件是否存在,是否正在写磁盘等),若检查不通过则退出处理,不会重启设备;
· 指定该参数时,系统将不进行任何检查,直接执行重启操作。
【使用指导】
· 重新启动可能会导致业务中断,请谨慎使用该命令。
· 使用force参数时,系统在重启时不会做任何保护性措施。重启后,可能导致文件系统损坏,请谨慎使用该参数。建议在系统故障或无法正常重启时,才使用该参数。
如果主用启动文件损坏或者不存在,则不能通过reboot命令重启设备。此时,可以通过指定新的主用启动文件再重启。
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。
重启全局主用主控板时,如果全局备用主控板不存在,会重启整个集群;如果全局备用主控板存在并稳定运行,会引起主备倒换。当系统中有单板处于非稳定状态时,请不要使用reboot命令来触发主备倒换,以免影响集群和单板的运行。可使用display system stable state命令来显示集群的稳定状态。
【举例】
# 重启设备,并保存配置文件。
<Sysname> reboot
Start to check configuration with next startup configuration file, please wait.........DONE!
Current configuration will be lost after the reboot, save current configuration? [Y/N]:y
Please input the file name(*.cfg)[flash:/startup.cfg]
(To leave the existing filename unchanged, press the enter key):
flash:/startup.cfg exists, overwrite? [Y/N]:y
Validating file. Please wait...
Configuration is saved to mainboard device successfully.
This command will reboot the device. Continue? [Y/N]:y
Now rebooting, please wait...
# 强制重启设备。
<Sysname> reboot force
A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y
Now rebooting, please wait...
【相关命令】
· display system stable state
reset alarm active命令用来清除设备当前仍未恢复的告警信息。
【命令】
reset alarm active { all | sequence-number sequence-number }
【缺省情况】
未清除设备当前仍未恢复的告警信息。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
all:清除设备当前仍未恢复的所有告警信息。
sequence-number sequence-number:清除指定序列号的未恢复的告警信息。sequence-number表示告警信息的序列号,取值范围为1~4294967295。
【使用指导】
当系统中存在无法恢复的告警记录信息时,用户可使用该命令自主清除其告警记录信息。清除后,在显示告警信息时,系统不会再对用户展现这些告警信息。
【举例】
# 清除序列号为1的未恢复告警信息。
<Sysname> system-view
[Sysname] reset alarm active sequence-number 1
【相关命令】
· display alarm active
· display alarm history
reset scheduler logfile命令用来清除Schedule日志文件的相关信息。
【命令】
reset scheduler logfile
【视图】
用户视图
【缺省用户角色】
network-admin
【使用指导】
仅在缺省MDC下支持本命令。
【举例】
# 清除Schedule日志文件的相关信息。
<Sysname> reset scheduler logfile
【相关命令】
· display scheduler logfile
reset version-update-record命令用来清除启动软件包版本更新操作的记录。
【命令】
reset version-update-record
【视图】
系统视图
【缺省用户角色】
network-admin
【使用指导】
仅在缺省MDC下支持本命令。
【举例】
# 清除设备启动软件包版本更新操作的记录。
<Sysname> system-view
[Sysname] reset version-update-record
This command will delete all records of version update. Continue? [Y/N]:y
【相关命令】
· display version-update-record
resource-monitor minor resend enable命令用来开启周期发送低级别资源告警通知功能。
undo resource-monitor minor resend enable命令用来关闭周期发送低级别资源告警通知功能。
【命令】
resource-monitor minor resend enable
undo resource-monitor minor resend enable
【缺省情况】
周期发送低级别资源告警通知功能处于开启状态。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【使用指导】
如果剩余的资源小于或等于低级别告警门限且大于高级别告警门限,则资源进入低级别告警状态,并生成低级别告警通知。
当资源一直处于低级别告警状态时:
· 开启周期发送低级别资源告警通知功能后,第一次达到低级别告警状态时,会生成低级别告警通知,后续还会周期生成低级别告警通知。当剩余资源达到更高级别告警门限时,将会生成更高级别的告警通知,暂时抑制低级别的告警通知。直到高级别的告警状态解除,再周期输出低级别的告警通知。
· 关闭周期发送低级别资源告警通知功能后,只有第一次达到低级别告警状态时,才生成低级别告警通知,不会连续生成低级别告警通知。
高级别告警通知重发功能一直处于开启状态,不能通过命令行配置。
高级别告警通知的重发周期是24小时,低级别告警通知的重发周期是7x24小时,不能配置。
【举例】
# 开启周期发送低级别资源告警通知功能。
<sysname> system-view
[Sysname] resource-monitor minor resend enable
【相关命令】
· display resource-monitor
· resource-monitor output
· resource-monitor resource
resource-monitor output命令用来配置资源告警通知的输出方向。
undo resource-monitor output命令用来关闭资源告警通知的输出方向。
【命令】
resource-monitor output { netconf-event | snmp-notification | syslog } *
undo resource-monitor output [ netconf-event | snmp-notification | syslog ]*
【缺省情况】
资源告警通知会同时向NETCONF、SNMP和 信息中心三个方向输出。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
netconf-event:将资源告警通知输出到NETCONF模块。
syslog:将资源告警通知输出到信息中心模块。
snmp-notification:将资源告警通知输出到SNMP模块。
【使用指导】
设备会实时监控一些重要资源的是使用情况,当达到指定门限时,设备会生成对应的资源告警通知,这些通知可以输出到以下三个方向:
· NETCONF模块。通过配置NETCONF模块的参数,可以将资源告警通知以NETCONF事件的形式发送给用户。关于NETCONF的详细介绍请参见“网络管理和监控配置指导”中的“NETCONF”。
· 信息中心模块。通过配置信息中心模块的参数,可以将资源告警通知以系统日志的形式发送给用户。关于信息中心的详细介绍请参见“网络管理和监控配置指导”中的“信息中心”。
· SNMP模块。通过配置SNMP模块的参数,可以将资源告警通知以Trap或者Inform消息的形式发送给用户。关于SNMP的详细介绍请参见“网络管理和监控配置指导”中的“SNMP”。
执行undo resource-monitor output命令,并且不指定可选参数时,表示资源告警通知不会向NETCONF、SNMP和信息中心三个方向输出。
【举例】
# 将资源告警通知输出到信息中心模块。
<sysname> system-view
[Sysname] resource-monitor output syslog
【相关命令】
· resource-monitor minor resend enable
· resource-monitor resource
resource-monitor resource命令用来配置生成资源告警通知的门限。
undo resource-monitor resource命令用来取消资源告警通知的门限配置。
【命令】
resource-monitor resource resource-name chassis chassis-number slot slot-number cpu cpu-number by-percent minor-threshold minor-threshold severe-threshold severe-threshold
undo resource-monitor resource resource-name chassis chassis-number slot slot-number cpu cpu-number
【缺省情况】
不同类型资源的缺省情况不同,请使用display resource-monitor命令查看。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
resource-name:需要监测的资源的名称,不区分大小写,需要完整输入参数的值。参数的取值请参见表1-41。
取值 |
含义 |
ac |
VXLAN服务实例资源 |
agg_group |
聚合组资源 |
arp |
ARP表项资源 |
arp_encap |
出方向封装表资源 |
ecmp_fec_1 |
一级ECMP FEC资源 |
ecmp_fec_2 |
级联的ECMP FEC资源 |
ecmpgroup |
等价路由组资源 |
g_rsvd_vlan |
全局保留VLAN资源 |
global_ecmp |
全局等价路由组资源 |
global_fec |
全局转发等价类资源 |
host |
主机路由资源 |
ipmc |
三层组播复制表资源 |
ipv4l2mc |
IPv4二层组播资源 |
ipv4l3mc |
IPv4三层组播资源 |
ipv6_127 |
掩码长度为65~127位的IPv6路由表项资源 |
ipv6_128 |
掩码长度为128位的IPv6路由表项资源 |
ipv6_64 |
掩码长度为0~64位的IPv6路由表项资源 |
ipv6l2mc |
IPv6二层组播资源 |
ipv6l3mc |
IPv6三层组播资源 |
l2mc |
VLAN内组播复制表资源 |
lem |
精确匹配路由表项资源 |
local_ecmp |
本地等价路由组资源 |
local_fec |
本地转发等价类资源 |
lpm |
最长匹配路由表项资源 |
mac |
MAC地址表项资源 |
mc |
二层和三层组播资源 |
mqcin |
入方向MQC资源 |
mqcout |
出方向MQC资源 |
nd |
ND表项资源 |
nexthoppool1 |
Underlay下一跳资源池资源 |
nexthoppool2 |
Overlay下一跳资源池资源 |
pbr |
PBR资源 |
pfilterin |
入方向包过滤资源 |
pfilterout |
出方向包过滤资源 |
route |
路由表项资源 |
rport |
三层以太网接口资源 |
rsvd_vlan |
本地保留VLAN资源 |
subrport |
三层以太网子接口资源 |
vlan |
VLAN资源 |
vlaninterface |
VLAN接口资源 |
vrf |
VPN实例资源 |
vsi |
VSI(Virtual Switch Instance,虚拟交换实例)资源 |
vsiintf |
VSI接口资源 |
slot slot-number:表示监测指定单板上的资源。slot-number表示单板所在的槽位号。
chassis chassis-number slot slot-number:表示监测指定单板上的资源。chassis-number表示设备在集群中的成员编号,slot-number表示单板所在的槽位号。
cpu cpu-number:表示监测指定CPU上的资源。cpu-number表示在CPU的编号。
by-percent:以百分比的方式配置告警门限。
minor-threshold minor-threshold:低级别告警门限。输入该参数的值时可通过输入?,来获取该参数的取值范围。
severe-threshold severe-threshold:高级别门限。输入该参数的值时可通过输入?,来获取该参数的取值范围。
【使用指导】
仅缺省MDC支持本命令。
配置本命令后,设备会监测资源的剩余情况,周期采样监测对象的值,并和配置的告警门限进行比较。当达到条件时,设备会生成告警通知。
【举例】
# 配置Chassis 1 slot 1上ARP资源的低级别门限为30%,高级别门限为10%。
<Sysname> system-view
[Sysname] resource-monitor resource arp Chassis 1 slot 1 cpu 0 by-percent minor-threshold 30 severe-threshold 10
【相关命令】
· display resource-monitor
· resource-monitor minor resend enable
· resource-monitor output
restore factory-default命令用来将设备恢复到出厂状态。
【命令】
restore factory-default
【视图】
用户视图
【缺省用户角色】
network-admin
【使用指导】
使用本命令会将设备恢复到出厂状态,请谨慎使用。
仅缺省MDC支持本命令。
当设备使用场景更改,或者设备出现故障时,可以使用本命令来将设备恢复到出厂状态。
执行该命令后,需手工重启设备才能使该命令生效。
【举例】
# 将设备恢复到出厂状态。
<Sysname> restore factory-default
This command will restore the system to the factory default configuration and clear the operation data. Continue [Y/N]:y
Restoring the factory default configuration. This process might take a few minutes. Please wait..........................................................................................................Done.
Please reboot the system to place the factory default configuration into effect.
【相关命令】
· reboot
scheduler job命令用来创建Job,并进入Job视图。如果指定的Job已存在,则直接进入Job视图。
undo scheduler job命令用来删除已创建的Job。
【命令】
scheduler job job-name
undo scheduler job job-name
【缺省情况】
不存在Job。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
job-name:Job的名称,为1~47个字符的字符串,区分大小写。
【使用指导】
一个Job可以被多个Schedule引用。Job视图下用户可以通过command命令为Job分配命令。
【举例】
# 创建名称为backupconfig的Job并进入Job视图。
<Sysname> system-view
[Sysname] scheduler job backupconfig
[Sysname-job-backupconfig]
【相关命令】
· command
· scheduler schedule
scheduler logfile size命令用来配置Schedule日志文件的大小。
【命令】
scheduler logfile size value
【缺省情况】
Schedule日志文件的大小为16KB。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
value:Schedule日志文件的大小,取值范围为16~1024,单位是KB。
【使用指导】
Schedule日志文件用来记录Job下命令行的执行结果。如果该文件的大小超过了用户配置值,则系统会把老的记录删除,用来记录新的记录。如果要记录的日志信息超长,超过了日志文件的大小,则该日志超出的部分不会记录。
【举例】
# 配置Schedule日志文件的大小为32KB。
<Sysname> system-view
[Sysname] scheduler logfile size 32
【相关命令】
· display scheduler logfile
scheduler reboot at命令用来配置设备重启的具体时间和日期。
undo scheduler reboot命令用来取消定时重启配置。
【命令】
scheduler reboot at time [ date ]
undo scheduler reboot
【缺省情况】
未配置设备重启的具体时间和日期。
【视图】
用户视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
time:设备重启的时间,格式为HH:MM。HH代表小时,取值范围为0~23,MM代表分钟,取值范围为0~59。
date:设备重启的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。
· YYYY的取值范围为2000~2035;
· MM的取值范围为1~12;
· DD的取值范围与具体月份有关。
【使用指导】
本命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用。
如果没有指定date参数,并且:
· 配置的时间点在当前时间之后,则设备将在当天的该时间点重启;
· 配置的时间点在当前时间之前,则设备将在第二天的该时间点重启。
多次配置scheduler reboot at、scheduler reboot delay命令,最后一次执行的命令生效。
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。
【举例】
# 假设系统的当前时间为2011年6月6日11:43,配置设备在当天中午12:00重启。
<Sysname> scheduler reboot at 12:00
Reboot system at 12:00:00 06/06/2011 (in 0 hours and 16 minutes). Confirm? [Y/N]:
【相关命令】
· scheduler reboot delay
scheduler reboot delay命令用来配置重启设备的延迟时间。
undo scheduler reboot命令用来取消定时重启配置。
【命令】
scheduler reboot delay time
undo scheduler reboot
【缺省情况】
未配置重启设备的延迟时间。
【视图】
用户视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
time:设备重启的等待时延,格式为HH:MM(小时:分钟)或MM(分钟)。
· 使用HH:MM格式时,MM的取值范围为0~59,HH:MM的最大长度为6个字符。
· 使用MM格式时,最大长度为6个字符。
【使用指导】
本命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用。
多次配置scheduler reboot at、scheduler reboot delay命令,最后一次执行的命令生效。
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。
【举例】
# 假设系统的当前时间为2011年6月6日11:48,配置设备在88分钟后重启。
<Sysname> scheduler reboot delay 88
Reboot system at 13:16 06/06/2011(in 1 hours and 28 minutes). Confirm? [Y/N]:
scheduler schedule命令用来创建Schedule,并进入相应的Schedule视图。如果指定的Schedule已存在,则直接进入Schedule视图。
undo scheduler schedule命令用来删除指定Schedule。
【命令】
scheduler schedule schedule-name
undo scheduler schedule schedule-name
【缺省情况】
不存在Schedule。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
schedule-name:Schedule的名称,为1~47个字符的字符串,区分大小写。
【使用指导】
使用scheduler schedule命令可以配置定时执行任务,让设备在指定时间执行指定命令。
配置步骤如下:
(1) 使用scheduler job命令创建Job。
(2) 在Job视图下,使用command命令配置需要执行的命令。
(3) 使用scheduler schedule命令创建Schedule。
(4) 在Schedule视图下,使用job命令为Schedule分配Job。一个Schedule下可以分配多个Job,但必须是已创建的Job,否则分配失败。
(5) 在Schedule视图下,使用user-role命令为Schedule配置用户角色。一个Schedule下最多可以分配64个角色。
(6) 在Schedule视图下,使用time at、time once或者time repeating命令来配置任务执行的时间。一个Schedule下只能配置一个执行时间。
【举例】
# 创建名为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
【相关命令】
· job
· time at
· time once
shutdown-interval命令用来配置端口状态检测定时器的时长。
undo shutdown-interval命令用来恢复缺省情况。
【命令】
shutdown-interval interval
undo shutdown-interval
【缺省情况】
端口状态检测定时器的时长为30秒。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
interval:端口状态检测定时器的时长,取值范围为0~300,单位为秒。取值为0时,表示系统不自动检测端口状态,需要用户执行undo shutdown命令手动恢复端口状态。
【使用指导】
某些协议模块在特定情况下会自动关闭某个端口。在协议自动关闭端口的同时,系统会启动一个检测端口状态的定时器。如果直到定时器超时(即经过time秒之后),该端口仍处于关闭状态,系统自动将端口恢复到真实的物理状态。
如果用户在端口定时检测过程中将检测时间间隔修改为T1,修改时刻距协议关闭端口时间间隔为T。
· 若T<T1,则被关闭的端口会再经过T1-T时间后被恢复。
· 若T>=T1,则被关闭的端口会立即恢复。
例如当前time配置为30,当端口被协议模块关闭2秒(T=2)后,修改time为10(T1=10),则该接口会再经过8秒后被恢复;如果当前time为30,端口被协议模块关闭10秒后,修改time为2,则该端口会立即恢复。
【举例】
# 配置端口状态检测定时器的时长为100秒。
<Sysname> system-view
[Sysname] shutdown-interval 100
sysname命令用来配置设备的名称。
undo sysname用来恢复缺省情况。
【命令】
sysname sysname
undo sysname
【缺省情况】
设备的名称为H3C。
【视图】
系统视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
sysname:设备名称,为1~64个字符的字符串。
【使用指导】
设备的名称对应于命令行接口的提示符,如设备的名称为Sysname,则用户视图的提示符为<Sysname>。
【举例】
# 配置设备的名称为R2000。
<Sysname> system-view
[Sysname] sysname R2000
system switchover命令用来手工触发主备倒换。
【命令】
system switchover [ chassis chassis-number ]
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
【使用指导】
仅缺省MDC支持本命令。
手工触发主备倒换时,原主用主控板会自动重启,所以,在执行本命令前,建议先保存当前配置。
执行本命令时:
· 如果指定的成员设备上只有一块主控板,不允许执行本命令。
· 如果命令行中指定的是主设备,且主设备上有两块主控板,则会触发集群系统内全局主用主控板和全局备用主控板之间的主备倒换。集群会选举一块全局备用主控板作为新的全局主用主控板,管理整个集群,原全局主用主控板会自动重启后重新加入集群。
· 如果命令行中指定的是备设备,且备设备上有两块主控板,则会触发该备设备内的本地主用主控板和本地备用主控板之间的主备倒换。本地备用主控板变成本地主用主控板,管理本设备,原本地主用主控板重启后自动加入集群。
【举例】
# 手工触发主用主控板和备用主控板的主备倒换。
<Sysname> system-view
[Sysname] system switchover
This command will trigger the election of a new active slot and reboot the original active slot. Continue? [Y/N]:y
Rebooting the original active slot. Please wait...
# 在非实时生效模式下,手工触发主用主控板和备用主控板的主备倒换。
<Sysname> system-view exclusive
Info: The current configuration is locked.
~[Sysname] system switchover
This operation will clear uncommitted changes. Continue? [Y/N]:y
This command will trigger the election of a new active slot and reboot the original active slot. Continue? [Y/N]:y
Rebooting the original active slot. Please wait...
temperature-limit命令用于配置设备的温度告警门限。
undo temperature-limit命令用来恢复缺省情况。
【命令】
temperature-limit chassis chassis-number slot slot-number { hotspot | inflow } sensor-number lowlimit warninglimit [ alarmlimit ]
undo temperature-limit chassis chassis-number slot slot-number { hotspot | inflow } sensor-number
【缺省情况】
不同温度传感器的温度门限可能不同,请先使用undo temperature-limit命令恢复缺省情况后,再通过display environment命令查看设备的缺省温度告警门限。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
chassis chassis-number:表示设备在集群中的成员编号。
slot slot-number:配置指定单板上温度传感器的温度门限。slot-number表示单板所在的槽位号。
hotspot:配置热点传感器的温度门限。热点传感器一般置于发热量较大的芯片附近,监测芯片温度。
inflow:配置入风传感器的温度门限。入风传感器一般置于入风口附近,监测环境温度。
sensor-number:温度传感器的编号,输入该参数的值时可通过输入?,来获取该参数的取值范围。
lowlimit:低温告警门限,单位为摄氏度。不同温度传感器的低温告警门限取值范围不同,输入该参数的值时可通过输入?,来获取该参数的取值范围。
warninglimit:一般级高温告警门限,单位为摄氏度,必须大于低温告警门限。输入该参数的值时可通过输入?,来获取该参数的取值范围。
alarmlimit:严重级高温告警门限,单位为摄氏度,必须大于一般级高温告警门限。输入该参数的值时可通过输入?,来获取该参数的取值范围。
【使用指导】
如果温度低于低温告警门限、高于一般级或严重级高温门限,系统均会生成相应的日志信息和告警信息提示用户,并通过设备面板上的指示灯来告警,以便用户及时进行处理。
本命令仅缺省MDC支持。
【举例】
# 配置指定chassis上热点1号温度传感器,低温门限为-10摄氏度,一般级高温门限为50摄氏度,严重级高温门限为60摄氏度。
<Sysname> system-view
[Sysname] temperature-limit chassis 1 slot 1 hotspot 1 -10 50 60
【相关命令】
· display environment
time at命令用来配置在指定时刻执行Schedule。
undo time命令用来为Schedule取消执行时间配置。
【命令】
time at time date
undo time
【缺省情况】
未为Schedule配置执行时间。
【视图】
Schedule视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
time:Schedule的执行时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。
date:Schedule执行的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。
· YYYY的取值范围为2000~2035;
· MM的取值范围为1~12;
· DD的取值范围与具体月份有关。
【使用指导】
配置的时间点必须晚于系统当前时间点,否则配置失败。
一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time at、time once或time repeating命令时,最后一次执行的命令生效。
【举例】
# 配置2011年5月11日1点1分执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time at 1:1 2011/05/11
【相关命令】
· scheduler schedule
time once命令用来为Schedule配置执行时间。
undo time命令用来为Schedule取消执行时间配置。
【命令】
time once at time [ month-date month-day | week-day week-day&<1-7> ]
time once delay time
undo time
【缺省情况】
未为Schedule配置执行时间。
【视图】
Schedule视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
at time:Schedule的执行时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。
month-date month-day:Schedule在一个月中的哪天被执行。month-day表示日期,取值范围为1~31。如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号。
week-day week-day&<1-7>:Schedule在一周中的哪(些)天被执行。week-day&<1-7>表示一周中任一天或几天的组合,week-day取值为:Mon、Tue、Wed、Thu、Fri、Sat、Sun,&<1-7>表示前面的参数最多可以输入7次。配置多天时,字符串之间用空格分开。
delay time:指定Schedule延迟执行的时间。格式为HH:MM(小时:分钟)或MM(分钟)。
· 使用HH:MM格式时,MM的取值范围为0~59,HH:MM最大长度为6个字符。
· 使用MM格式时,最大长度为6个字符。
【使用指导】
配置该命令后,Schedule在该设定时间点到达时执行,若当天/本月/本周该时间点已过去,则顺延到第二天/下月/下周。执行后下次再到达该时间点时Schedule不再执行。
一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time at、time once或time repeating命令时,最后一次执行的命令生效。
【举例】
# 当天的15点执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once at 15:00
# 最近到达的15号的15点执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once at 15:00 month-date 15
# 最近一个周一和周五的12点整执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once at 12:00 week-day mon fri
# 延迟10分钟执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time once delay 10
【相关命令】
· scheduler schedule
time repeating命令用来配置重复执行Schedule的时间。
undo time命令用来为Schedule取消执行时间配置。
【命令】
time repeating [ at time [ date ] ] interval interval
time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]
undo time
【缺省情况】
未配置重复执行Schedule的时间。
【视图】
Schedule视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
at time:表示重复执行的时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。不指定该参数时,表示从现在开始。
date:指定Schedule重复执行的开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。不指定该参数时,表示将来第一次到达time的时间点的日期。
· YYYY的取值范围为2000~2035;
· MM的取值范围为1~12;
· DD的取值范围与具体月份有关。
interval interval:指定重复执行的时间间隔。格式为HH:MM(小时:分钟)或MM(分钟)。
· 使用HH:MM格式时,MM的取值范围为0~59,最大长度为6个字符。
· 使用MM格式时,取值的最小值为1,最大长度为6个字符。
month-date [ month-day | last ]:表示每月中的某一天。其中,month-day表示日期,取值范围为1~31。如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号。last表示每月的最后一天。
week-day week-day&<1-7>:表示每周中的某(些)天。week-day&<1-7>表示一周中任一天或几天的组合,week-day取值为:Mon、Tue、Wed、Thu、Fri、Sat、Sun,&<1-7>表示前面的参数最多可以输入7次。配置多天时,字符串之间用空格分开。
【使用指导】
time repeating [ at time [ date ] ] interval interval表示从指定时间开始,周期性执行Schedule。
time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]表示每月/每周的某(些)天重复执行Schedule。
一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time at、time once或time repeating命令时,最后一次执行的命令生效。
【举例】
# 配置从早上八点开始,每隔1小时执行一次名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 interval 60
# 配置从现在开始每天的12:00执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 12:00
# 配置从现在开始每个月5号的上午8点执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 month-date 5
# 配置从现在开始每个月的最后一天8点执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 month-date last
# 配置从现在开始每个周五和周六的上午8点执行名称为saveconfig的Schedule。
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time repeating at 8:00 week-day fri sat
【相关命令】
· scheduler schedule
usb disable命令用来关闭USB接口。
undo usb disable命令用来开启USB接口。
【命令】
usb disable
undo usb disable
【缺省情况】
设备上所有的USB接口处于开启状态。
【视图】
系统视图
【缺省用户角色】
network-admin
【使用指导】
仅缺省MDC支持本命令。
用户可通过USB口进行文件的上传和下载。缺省状态下USB口处于开启状态,用户可根据需要关闭USB口。
在执行usb disable命令前,请先使用umount命令卸载所有USB分区,否则命令执行失败。有关umount命令的详细介绍,请参见“基础配置命令参考”中的“文件系统管理”。
【举例】
# 关闭USB接口,请先umount所有USB分区。
<Sysname> umount usba0:
<Sysname> system-view
[Sysname] usb disable
# 打开USB接口。
<Sysname> system-view
[Sysname] undo usb disable
user-role命令用来配置执行Schedule时使用的用户角色。
undo user-role命令用来将已经配置的用户角色从Schedule中删除。
【命令】
user-role role-name
undo user-role role-name
【缺省情况】
执行Schedule时使用的用户角色,为创建该Schedule的用户的用户角色。
【视图】
Schedule视图
【缺省用户角色】
network-admin
mdc-admin
【参数】
role-name:用户角色的名称,为1~63个字符的字符串,区分大小写。可以是系统预定义的角色名称,包括network-admin、network-operator、mdc-admin、mdc-operator、level-0~level-15,也可以是自定义的用户角色名称。
【使用指导】
设备支持的每条命令执行时都需要相应的用户角色。只有本命令中配置的用户角色具有权限,Schedule中的command命令中指定的命令行才能执行。关于用户角色的详细描述请参见“基础配置指导”中的“RBAC”。
同一Schedule最多可配置64个用户角色,超过该上限后,新配置会执行失败。
安全日志管理员角色与其它用户角色互斥:配置安全日志管理员角色后,系统会自动删除已配置的其它用户角色;配置其它用户角色后,系统会自动删除已配置的安全日志管理员角色。
【举例】
# 配置执行定时任务test时使用的用户角色为rolename。
<sysname> system-view
[Sysname] scheduler schedule test
[Sysname-schedule-test] user-role rolename
# 配置执行定时任务test时使用的用户角色为security-audit。
<sysname> system-view
[Sysname] scheduler schedule test
[Sysname-schedule-test]user-role security-audit
This operation will delete all other user roles for the schedule. Are you sure? [Y/N]:y
# 将执行定时任务test时使用的用户角色从security-audit修改为network-admin。
<sysname> system-view
[Sysname] scheduler schedule test
[Sysname-schedule-test]user-role network-admin
This operation will delete security auditor user role for the schedule. Are you sure? [Y/N]:y
【相关命令】
· command
· scheduler schedule
不同款型规格的资料略有差异, 详细信息请向具体销售和400咨询。H3C保留在没有任何通知或提示的情况下对资料内容进行修改的权利!