03-Device Management

HomeSupportRoutersCR16000-F SeriesReference GuidesMIB CompanionH3C CR16000-F Routers MIB Reference-R8530Pxx-6W10003-Device Management
02-HH3C-COMMON-SYSTEM-MIB
Title Size Download
02-HH3C-COMMON-SYSTEM-MIB 121.71 KB

HH3C-COMMON-SYSTEM-MIB

About this MIB

Use this MIB to perform basic operations on the device. For example, access this MIB to reboot the device, obtain basic system information such as reboot mode and system operating mode, and send poweroff alarms. This MIB also contains notifications about device operation changes.

MIB file name

hh3c-common-system.mib

Root object

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cSystem(6)

Scalar objects

hh3cReboot (1.3.6.1.4.1.25506.6.7)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cReboot (1.3.6.1.4.1.25506.6.7)

read-write

INTEGER

normal(0), reboot(1)

Reboots the device.

As per the MIB.

 

hh3cSysBootType (1.3.6.1.4.1.25506.6.10)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSysBootType (1.3.6.1.4.1.25506.6.10)

read-only

INTEGER

coldStart(1), warmStart(2)

Boot mode of the system.

Implementation varies by the product.

 

hh3cSystemWorkingModeDefault (1.3.6.1.4.1.25506.6.14.2)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSystemWorkingModeDefault (1.3.6.1.4.1.25506.6.14.2)

read-only

Integer32

Integer32 (1..2147483647)

Default system operating mode.

Implementation varies by product.

 

hh3cSystemWorkingModeCurrent (1.3.6.1.4.1.25506.6.14.3)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSystemWorkingModeCurrent (1.3.6.1.4.1.25506.6.14.3)

read-only

Integer32

Integer32 (1..2147483647)

Current system operating mode.

Implementation varies by product.

 

hh3cSystemWorkingModeNext (1.3.6.1.4.1.25506.6.14.4)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSystemWorkingModeNext (1.3.6.1.4.1.25506.6.14.4)

read-write

Integer32

Integer32 (1..2147483647)

The system operating mode for the next startup.

Implementation varies by product.

For the modified operating mode to take effect, reboot the device, The new operating mode will take effect on the entire device.

 

hh3cSysBannerMOTD (1.3.6.1.4.1.25506.6.11.11)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSysBannerMOTD (1.3.6.1.4.1.25506.6.11.11)

read-write

OCTETSTRING

OCTET STRING (0..2000)

Banner message.

As per the MIB.

 

hh3cSystemCurrentEnergySavingMode(1.3.6.1.4.1.25506.6.16)

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSystemCurrentEnergySavingMode(1.3.6.1.4.1.25506.6.16)

read-write

OCTETSTRING

OCTET STRING (0..16)

Current energy saving mode in the system. Null indicates that no energy saving mode is specified.

As per the MIB.

 

Tabular objects

hh3cSystemDiagInfoTable

About this table

This table creates diagnosis files for the system.

Support for operations

CreateSupported

Edit/ModifyNot supported

DeleteSupported

ReadSupported

Columns

The table index is hh3cSystemDiagInfoIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSystemDiagInfoIndex (1.3.6.1.4.1.25506.6.13.1.1)

not-accessible

Integer32

Integer32 (1..2147483647)

Entry index.

As per the MIB.

hh3cSystemDiagInfoFilename (1.3.6.1.4.1.25506.6.13.1.2)

read-create

DisplayString

OCTET STRING (0..255)

Diagnosis file name.

As per the MIB.

The system uses the default file name if you do not specify a file name during row creation.

hh3cSystemDiagInfoRowStatus (1.3.6.1.4.1.25506.6.13.1.3)

read-create

RowStatus

active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)

Row status.

As per the MIB.

hh3cSystemDiagInfoOperEndTime(1.3.6.1.4.1.25506.6.13.1.4)

read-only

TimeStamp

Standard MIB values.

Time when the operation was completed.

As per the MIB.

hh3cSystemDiagInfoOperState (1.3.6.1.4.1.25506.6.13.1.5)

read-only

INTEGER

opInProgress(1),opSuccess(2),opFailure(3)

Operation status.

As per the MIB.

hh3cSystemDiagInfoOperFailReason (1.3.6.1.4.1.25506.6.13.1.6)

read-only

DisplayString

OCTET STRING (0..255)

Failure reason.

As per the MIB.

 

hh3cSystemWorkingModeTable

About this table

This table contains information about the system operating modes supported on the device.

Support for operations

CreateNot supported

Edit/ModifyNot supported

DeleteNot supported

ReadSupported

Columns

The table index is hh3cSystemWorkingModeIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cSystemWorkingModeIndex (1.3.6.1.4.1.25506.6.14.1.1.1)

not-accessible

Integer32

Integer32 (1..2147483647)

Index of a system operating mode.

Implementation varies by product.

hh3cSystemWorkingModeName (1.3.6.1.4.1.25506.6.14.1.1.2)

read-only

DisplayString

OCTET STRING (1..32)

Name of the system operating mode.

Implementation varies by product.

hh3cSystemWorkingModeDescr (1.3.6.1.4.1.25506.6.14.1.1.3)

read-only

DisplayString

OCTET STRING (1..128)

Description of the system operating mode.

Implementation varies by product.

 

Notifications

hh3cRebootSendTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.6.8.3

The device is to reboot

Informational

Major

N/A (N/A)

ON

 

Notification triggers

This notification is generated two seconds before the reboot command is used to reboot the device.

System impact

The system will stop providing services and restart.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

()

 

Recommended action

No action is required.

hh3cSysColdStartTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.6.8.4

A cold boot was performed

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a cold boot is performed on the device.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.6.11.10 (hh3cSysFirstTrapTime)

Time when the alarm occurred.

N/A

TimeTicks

Standard MIB values.

 

Recommended action

No action is required.

hh3cSysWarmStartTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.6.8.5

A warm boot was performed

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is generated when a warm boot is performed on the device.

System impact

No negative impact on the system.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.6.11.10 (hh3cSysFirstTrapTime)

Time when the alarm occurred.

N/A

TimeTicks

Standard MIB values.

 

Recommended action

No action is required.

hh3cSysDyingGaspTrap

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.6.8.7

Poweroff alarm

Informational

Critical

N/A (N/A)

ON

 

Notification triggers

This notification is generated when the device is powered off.

System impact

The system will be powered off and stop providing services.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

()

 

Recommended action

Verify that the power cord is connected correctly.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网