RMON-MIB
About this MIB
Use this MIB to monitor data traffic on a network segment or the entire network.
MIB file name
rfc2819-rmon.mib
Root object
iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).rmon(16)
Tabular objects
etherStatsTable
About this table
Use this table to obtain statistics about Ethernet interfaces.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
You must specify etherStatsDataSource and etherStatsStatus in pairs when creating a row of instances. |
Not supported |
Supported |
Supported |
Columns
The table index is etherStatsIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
etherStatsIndex (1.3.6.1.2.1.16.1.1.1.1) |
read-only |
Integer32 |
Integer32 (1..65535) |
Index of an etherStats entry. |
As per the MIB. |
etherStatsDataSource (1.3.6.1.2.1.16.1.1.1.2) |
read-create |
OBJECT IDENTIFIER |
Standard MIB values. |
Interface on which statistics are gathered. |
As per the MIB. |
etherStatsDropEvents (1.3.6.1.2.1.16.1.1.1.3) |
read-only |
Counter32 |
Standard MIB values. |
Total number of events in which packets were dropped. |
Implementation varies by product.. |
etherStatsOctets (1.3.6.1.2.1.16.1.1.1.4) |
read-only |
Counter32 |
Standard MIB values. |
Total number of octets received on the interface. |
Implementation varies by product. |
etherStatsPkts (1.3.6.1.2.1.16.1.1.1.5) |
read-only |
Counter32 |
Standard MIB values. |
Total number of packets received on the interface. |
Implementation varies by product. |
etherStatsBroadcastPkts (1.3.6.1.2.1.16.1.1.1.6) |
read-only |
Counter32 |
Standard MIB values. |
Total number of broadcast packets received on the interface. |
Implementation varies by product. |
etherStatsMulticastPkts (1.3.6.1.2.1.16.1.1.1.7) |
read-only |
Counter32 |
Standard MIB values. |
Total number of multicast packets received on the interface. |
Implementation varies by product. |
etherStatsCRCAlignErrors (1.3.6.1.2.1.16.1.1.1.8) |
read-only |
Counter32 |
Standard MIB values. |
Total number of packets with CRC errors received on the interface. |
Implementation varies by product. |
etherStatsUndersizePkts (1.3.6.1.2.1.16.1.1.1.9) |
read-only |
Counter32 |
Standard MIB values. |
Total number of undersize packets received on the interface. |
Implementation varies by product. |
etherStatsOversizePkts (1.3.6.1.2.1.16.1.1.1.10) |
read-only |
Counter32 |
Standard MIB values. |
Total number of oversize packets received on the interface. |
Implementation varies by product. |
etherStatsFragments (1.3.6.1.2.1.16.1.1.1.11) |
read-only |
Counter32 |
Standard MIB values. |
Total number of undersize packets with FCS errors received on the interface. |
Implementation varies by product. |
etherStatsJabbers (1.3.6.1.2.1.16.1.1.1.12) |
read-only |
Counter32 |
Standard MIB values. |
Total number of oversize packets with FCS errors received on the interface. |
Implementation varies by product. |
etherStatsCollisions (1.3.6.1.2.1.16.1.1.1.13) |
read-only |
Counter32 |
Standard MIB values. |
Total number of colliding packets received on the interface. |
Implementation varies by product. |
etherStatsPkts64Octets (1.3.6.1.2.1.16.1.1.1.14) |
read-only |
Counter32 |
Standard MIB values. |
Total number of packets with a length smaller than or equal to 64 octets received on the interface. |
Implementation varies by product. |
etherStatsPkts65to127Octets (1.3.6.1.2.1.16.1.1.1.15) |
read-only |
Counter32 |
Standard MIB values. |
Total number of 65- to 127-octet packets received on the interface. |
Implementation varies by product. |
etherStatsPkts128to255Octets (1.3.6.1.2.1.16.1.1.1.16) |
read-only |
Counter32 |
Standard MIB values. |
Total number of 128- to 255-octet packets received on the interface |
Implementation varies by product. |
etherStatsPkts256to511Octets (1.3.6.1.2.1.16.1.1.1.17) |
read-only |
Counter32 |
Standard MIB values. |
Total number of 256- to 511-octet packets received on the interface. |
Implementation varies by product. |
etherStatsPkts512to1023Octets (1.3.6.1.2.1.16.1.1.1.18) |
read-only |
Counter32 |
Standard MIB values. |
Total number of 512- to 1023-octet packets received on the interface |
Implementation varies by product. |
etherStatsPkts1024to1518Octets (1.3.6.1.2.1.16.1.1.1.19) |
read-only |
Counter32 |
Standard MIB values. |
Total number of 1024- to 1518-octet packets received on the interface |
Supported. HMIM-24GSW HMIM-1GBE HMIM-2GBE HMIM-2GEE HMIM-4GEE HMIM-8GEE HMIM-2GEF HMIM-4GEF HMIM-8GEF (1024 to MRU) |
etherStatsOwner (1.3.6.1.2.1.16.1.1.1.20) |
read-create |
OwnerString |
OCTET STRING (0..127) |
Owner of the etherStats entry. |
Not-displayable characters or question marks are not allowed. The default value is a zero-length string. |
etherStatsStatus (1.3.6.1.2.1.16.1.1.1.21) |
read-create |
EntryStatus |
valid(1), |
Status of the etherStats entry. |
As per the MIB. |
historyControlTable
About this table
Use this table to configure history control entries.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
You must specify historyControlDataSource and historyControlStatus in pairs when creating an instance. |
Not supported |
Supported |
Supported |
Columns
The table index is historyControlIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
historyControlIndex (1.3.6.1.2.1.16.2.1.1.1) |
read-only |
Integer32 |
Integer32 (1..65535) |
Index of a historyControl entry. |
As per the MIB. |
historyControlDataSource (1.3.6.1.2.1.16.2.1.1.2) |
read-create |
OBJECT IDENTIFIER |
Standard MIB values. |
Interface on which historical data was collected. |
As per the MIB. |
historyControlBucketsRequested (1.3.6.1.2.1.16.2.1.1.3) |
read-create |
Integer32 |
Integer32 (1..65535) |
Requested number of samples to be retained for the entry. |
A maximum of 50 samples are supported. You can set a value larger than 50 for this object, but only 50 samples are supported. |
historyControlBucketsGranted (1.3.6.1.2.1.16.2.1.1.4) |
read-only |
Integer32 |
Integer32 (1..65535) |
Granted number of samples to be retained for the entry. |
As per the MIB. |
historyControlInterval (1.3.6.1.2.1.16.2.1.1.5) |
read-create |
Integer32 |
Integer32 (1..3600) |
Sampling interval in seconds. |
Value range: 5 to 3600 Default: 1800 |
historyControlOwner (1.3.6.1.2.1.16.2.1.1.6) |
read-create |
OwnerString |
OCTET STRING (0..127) |
Owner of this entry. |
Not-displayable characters or question marks are not allowed. The default value is a zero-length string. |
historyControlStatus (1.3.6.1.2.1.16.2.1.1.7) |
read-create |
EntryStatus |
valid(1), |
Statistics about this entry. |
As per the MIB. |
etherHistoryTable
About this table
Use this table to obtain information about RMON history control entries and history samples of Ethernet statistics for Ethernet interfaces.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
Not supported |
Not supported |
Not supported |
Supported |
Columns
The table indexes are etherHistoryIndex and etherHistorySampleIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
etherHistoryIndex (1.3.6.1.2.1.16.2.2.1.1) |
read-only |
Integer32 |
Integer32 (1..65535) |
Index of an etherHistory entry. |
As per the MIB. |
etherHistorySampleIndex (1.3.6.1.2.1.16.2.2.1.2) |
read-only |
Integer32 |
Integer32 (1..2147483647) |
Index of a sample. |
As per the MIB. |
etherHistoryIntervalStart (1.3.6.1.2.1.16.2.2.1.3) |
read-only |
TimeTicks |
Standard MIB values. |
Sampling start time. |
As per the MIB. |
etherHistoryDropEvents (1.3.6.1.2.1.16.2.2.1.4) |
read-only |
Counter32 |
Standard MIB values. |
Total number of events in which packets were dropped during this sampling interval. |
Implementation varies by product. |
etherHistoryOctets (1.3.6.1.2.1.16.2.2.1.5) |
read-only |
Counter32 |
Standard MIB values. |
Total number of octets received on the interface during this sampling interval. |
Implementation varies by product. |
etherHistoryPkts (1.3.6.1.2.1.16.2.2.1.6) |
read-only |
Counter32 |
Standard MIB values. |
Total number of packets received during this sampling interval. |
Implementation varies by product. |
etherHistoryBroadcastPkts (1.3.6.1.2.1.16.2.2.1.7) |
read-only |
Counter32 |
Standard MIB values. |
Total number of broadcast packets received during this sampling interval. |
Implementation varies by product. |
etherHistoryMulticastPkts (1.3.6.1.2.1.16.2.2.1.8) |
read-only |
Counter32 |
Standard MIB values. |
Total number of multicast packets received during this sampling interval. |
Implementation varies by product. |
etherHistoryCRCAlignErrors (1.3.6.1.2.1.16.2.2.1.9) |
read-only |
Counter32 |
Standard MIB values. |
Total number of packets with CRC alignment errors received during the sampling interval. |
Implementation varies by product. |
etherHistoryUndersizePkts (1.3.6.1.2.1.16.2.2.1.10) |
read-only |
Counter32 |
Standard MIB values. |
Total number of undersize packets received during the sampling interval. |
Implementation varies by product. |
etherHistoryOversizePkts (1.3.6.1.2.1.16.2.2.1.11) |
read-only |
Counter32 |
Standard MIB values. |
Total number of oversize packets received during the sampling interval. |
Implementation varies by product. |
etherHistoryFragments (1.3.6.1.2.1.16.2.2.1.12) |
read-only |
Counter32 |
Standard MIB values. |
Total number of undersize packets with FCS errors received during the sampling interval. |
Implementation varies by product. |
etherHistoryJabbers (1.3.6.1.2.1.16.2.2.1.13) |
read-only |
Counter32 |
Standard MIB values. |
Total number of oversize packets with FCS errors received during the sampling interval. |
Implementation varies by product. |
etherHistoryCollisions (1.3.6.1.2.1.16.2.2.1.14) |
read-only |
Counter32 |
Standard MIB values. |
Total number of colliding packets received during the sampling interval. |
Implementation varies by product. |
etherHistoryUtilization (1.3.6.1.2.1.16.2.2.1.15) |
read-only |
Integer32 |
Integer32 (0..10000) |
Bandwidth utilization during the sampling period. |
Implementation varies by product. |
alarmTable
About this table
Use this table to configure alarm entries.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
You must specify alarmVariable and alarmStatus in pairs when creating a row of instances. If the buildruns of the instances exceed the maximum specification, the creation fails. |
Not supported |
Supported |
Supported |
Columns
The table index is alarmIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
alarmIndex (1.3.6.1.2.1.16.3.1.1.1) |
read-only |
Integer32 |
Integer32 (1..65535) |
Index of an RMON alarm entry. |
As per the MIB. |
alarmInterval (1.3.6.1.2.1.16.3.1.1.2) |
read-create |
Integer32 |
Standard MIB values. |
Sampling interval in seconds. |
Value range: 5 to 3600. Default value: 1800. |
alarmVariable (1.3.6.1.2.1.16.3.1.1.3) |
read-create |
OBJECT IDENTIFIER |
Standard MIB values. |
OID of the variable to be sampled. |
As per the MIB. |
alarmSampleType (1.3.6.1.2.1.16.3.1.1.4) |
read-create |
INTEGER |
absoluteValue(1), |
Sampling type. |
Default value: absoluteValue(1). |
alarmValue (1.3.6.1.2.1.16.3.1.1.5) |
read-only |
Integer32 |
Standard MIB values. |
Value of the sampled variable. |
If the object value exceeds the maximum positive value, the negation of the object value is returned when read. |
alarmStartupAlarm (1.3.6.1.2.1.16.3.1.1.6) |
read-create |
INTEGER |
risingAlarm(1), |
Alarms that can be generated at the first sampling. |
Default value: risingOrFallingAlarm(3). |
alarmRisingThreshold (1.3.6.1.2.1.16.3.1.1.7) |
read-create |
Integer32 |
Standard MIB values. |
Rising threshold. |
Default value: 1. |
alarmFallingThreshold (1.3.6.1.2.1.16.3.1.1.8) |
read-create |
Integer32 |
Standard MIB values. |
Falling threshold. |
Default value: 0. |
alarmRisingEventIndex (1.3.6.1.2.1.16.3.1.1.9) |
read-create |
Integer32 |
Integer32 (0..65535) |
Index of the event that is triggered when the rising threshold is crossed. |
Default value: 0. |
alarmFallingEventIndex (1.3.6.1.2.1.16.3.1.1.10) |
read-create |
Integer32 |
Integer32 (0..65535) |
Index of the event that is triggered when the falling threshold is crossed. |
Default value: 0. |
alarmOwner (1.3.6.1.2.1.16.3.1.1.11) |
read-create |
OwnerString |
OCTET STRING (0..127) |
Owner of the alarm entry. |
Not-displayable characters or question marks are not allowed. Default value: zero-length string. |
alarmStatus (1.3.6.1.2.1.16.3.1.1.12) |
read-create |
EntryStatus |
valid(1), createRequest(2), underCreation(3), invalid(4) |
Status of the alarm entry. |
As per the MIB. |
eventTable
About this table
Use this table to configure event entries.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
Supported. You must specify eventStatus when creating a row of instances. If the buildruns of the instances exceed the maximum specification, the creation fails. |
Not supported |
Supported |
Supported |
Columns
The table index is eventIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
eventIndex (1.3.6.1.2.1.16.9.1.1.1) |
read-only |
Integer32 |
Integer32 (1..65535) |
Event entry index. |
As per the MIB. |
eventDescription (1.3.6.1.2.1.16.9.1.1.2) |
read-create |
DisplayString |
OCTET STRING (0..127) |
Event description. |
Default value: Zero-length string. |
eventType (1.3.6.1.2.1.16.9.1.1.3) |
read-create |
INTEGER |
none(1), log(2), snmptrap(3), logandtrap(4) |
Event type. |
Default value: none(1) |
eventLastTimeSent (1.3.6.1.2.1.16.9.1.1.5) |
read-only |
TimeTicks |
TimeTicks (0..4294967295) |
Time at which the most recent event occurs. |
As per the MIB. |
eventOwner (1.3.6.1.2.1.16.9.1.1.6) |
read-create |
OwnerString |
OCTET STRING (0..127) |
Event owner. |
Not-displayable characters or question marks are not allowed. Default value: Zero-length string. |
eventStatus (1.3.6.1.2.1.16.9.1.1.7) |
read-create |
EntryStatus |
valid(1), createRequest(2), underCreation(3), invalid(4) |
Event status. |
As per the MIB. |
logTable
About this table
Use this table to obtain event logs.
Support for operations
Create |
Edit/Modify |
Delete |
Read |
Not supported |
Not supported |
Not supported |
Supported |
Columns
The table indexes are logEventIndex and logIndex.
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
logEventIndex (1.3.6.1.2.1.16.9.2.1.1) |
read-only |
Integer32 |
Integer32 (1..65535) |
Index of the event entry that generated this log entry. |
As per the MIB. |
logIndex (1.3.6.1.2.1.16.9.2.1.2) |
read-only |
Integer32 |
Integer32 (1..2147483647) |
Index of the log entry. |
As per the MIB. |
logTime (1.3.6.1.2.1.16.9.2.1.3) |
read-only |
TimeTicks |
Standard MIB values. |
Time when the log entry was created. |
As per the MIB. |
logDescription (1.3.6.1.2.1.16.9.2.1.4) |
read-only |
DisplayString |
OCTET STRING (0..255) |
Description of the event that activated this log entry. |
As per the MIB. |
Notifications
risingAlarm
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.2.1.16.0.1 |
A variable of an alarm entry crossed its rising threshold. |
Informational |
Warning |
N/A |
ON |
Notification triggers
This notification is generated when a variable of an alarm entry crosses its rising threshold and the triggered event is to send SNMP notifications.
System impact
No impact on services.
Status control
ON
CLI: Use the rmon event entry-number [ description string ] { log-trap security-string | trap security-string } [ owner text ] command.
OFF
CLI: Use the rmon event entry-number [ description string ] { log | none } [ owner text ] command.
Objects
OID (object name) |
Description |
Index nodes |
Type |
Value range |
1.3.6.1.2.1.16.3.1.1.1 (alarmIndex) |
Index of the alarm entry |
alarmIndex |
Integer32 |
1..65535 |
1.3.6.1.2.1.16.3.1.1.3 (alarmVariable) |
Variable to be sampled |
alarmIndex |
OBJECT IDENTIFIER |
Standard MIB values. |
1.3.6.1.2.1.16.3.1.1.4 (alarmSampleType) |
Sampling type |
alarmIndex |
INTEGER |
absoluteValue(1) deltaValue(2) |
1.3.6.1.2.1.16.3.1.1.5 (alarmValue) |
Sampled value |
alarmIndex |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.16.3.1.1.7 (alarmRisingThreshold) |
Rising threshold |
alarmIndex |
Integer32 |
Standard MIB values. |
Recommended action
To resolve the issue:
1. Execute the display rmon alarm command in any view to check information about the monitored variable and rising threshold. Locate and remove the reason causing the notification.
If the rising threshold is inappropriate, execute the rmon alarm command in system view to change the rising threshold.
2. If the issue persists, collect alarm information and configuration data and then contact H3C Support for help.
fallingAlarm
Basic information
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
1.3.6.1.2.1.16.0.2 |
A variable of an alarm entry fell to or below its falling threshold. |
Informational |
Warning |
N/A |
ON |
Notification triggers
This notification is generated when a variable of an alarm entry falls to or below its falling threshold and the triggered event is to send SNMP notifications.
System impact
No impact on services.
Status control
ON
CLI: Use the rmon event entry-number [ description string ] { log-trap security-string | trap security-string } [ owner text ] command.
OFF
CLI: Use the rmon event entry-number [ description string ] { log | none } [ owner text ] command.
Objects
OID (object name) |
Description |
Index nodes |
Type |
Value range |
1.3.6.1.2.1.16.3.1.1.1 (alarmIndex) |
Index of the alarm entry |
alarmIndex |
Integer32 |
1..65535 |
1.3.6.1.2.1.16.3.1.1.3 (alarmVariable) |
Variable to be sampled |
alarmIndex |
OBJECT IDENTIFIER |
Standard MIB values. |
1.3.6.1.2.1.16.3.1.1.4 (alarmSampleType) |
Sampling type |
alarmIndex |
INTEGER |
absoluteValue(1), deltaValue(2) |
1.3.6.1.2.1.16.3.1.1.5 (alarmValue) |
Sampled value |
alarmIndex |
Integer32 |
Standard MIB values. |
1.3.6.1.2.1.16.3.1.1.8 (alarmFallingThreshold) |
Falling threshold |
alarmIndex |
Integer32 |
Standard MIB values. |
Recommended action
1. Execute the display rmon alarm command in any view to check information about the monitored variable and falling threshold. Locate and remove the reason causing the notification.
If the falling threshold is inappropriate, execute the rmon alarm command in system view to change the falling threshold.
2. If the issue persists, collect alarm information and configuration data and then contact H3C Support for help.