H3C UniServer B5700 G6 Blade Server User Guide-6W100

HomeSupportServersBlade ServerH3C UniServer B16000H3C UniServer B5700 G6Technical DocumentsInstall & UpgradeInstallation GuidesH3C UniServer B5700 G6 Blade Server User Guide-6W100
02-Appendix
Title Size Download
02-Appendix 75.25 KB

Appendix A  Specifications and support information

Component specifications

For components compatible with the server and detailed component information, use the component compatibility lookup tool at http://www.h3c.com/en/home/qr/default.htm?id=66.

Operating temperature requirements

Table 1 Operating temperature requirements on the server

Drive configuration

Max. temperature

30°C (86°F)

35°C (86°F)

40°C (86°F)

3SFF model with drive configurations

All configurations are supported.

·     Processors with a TDP of 225W or higher are not supported.

·     All fan modules must operate correctly.

·     DDR5 DIMMs of 64G are not supported.

·     Processors with a TDP of 225W or higher are not supported.

·     Mezz cards are not supported.

·     All fan modules must operate correctly.

Dual-network adapter model with drive configurations

All configurations are supported.

·     Processors with a TDP of 225W or higher are not supported.

·     All fan modules must operate correctly.

·     DDR5 DIMMs of 64G are not supported.

·     Processors with a TDP of 225W or higher are not supported.

·     Mezz cards are not supported.

·     All fan modules must operate correctly.

When a fan module fails or a single rotor of a dual-rotor fan module fails, the maximum server operating temperature decreases by 8°C (46.4°F) and the performance of GPUs and processors that support throttling might decrease.

 

Technical support

To resolve issues during routine maintenance or troubleshooting, contact Technical Support.

Obtaining the most recent firmware or software

To obtain the most recent firmware or software, access https://www.h3c.com/en/BizPortal/DownLoadAccessory/en_DownLoadAccessoryFilt.aspx.

Collecting information

To facilitate troubleshooting, collect the following server information before contacting Technical Support:

·     Log and sensor information.

·     Product serial number.

·     Product model and name.

·     Screenshots of error messages and descriptions.

·     Hardware change records, including installation, replacement, insertion, and removal of hardware components.

·     Third-party software.

·     Operating system type and version.

Preparing maintenance tools

To facilitate troubleshooting, prepare the following tools: 

·     T-25 Torx screwdriver.

·     T-15 Torx screwdriver.

·     Monitor (such as PC).

·     ESD wrist strap, antistatic gloves, and antistatic clothing.

For more information about these tools, see "Installation tools."

Product security and compatibility

For information about the product security and compatibility, see the security and compatibility manual for the server.

Product recycling

New H3C Technologies Co., Ltd. provides product recycling services for its customers to ensure that hardware at the end of its life is recycled. Vendors with product recycling qualification are contracted to New H3C to process the recycled hardware in an environmentally responsible way.

For product recycling services, contact New H3C at

·     Tel: 400-810-0504

·     E-mail: [email protected]

·     Website: http://www.h3c.com

Glossary

Item

Description

B

BIOS

The Basic Input Output System (BIOS) is a collection of programs stored on a ROM chip on the server motherboard. It includes critical components such as the Basic Input Output Program, Power-On Self-Test (POST), and system startup programs. The BIOS provides the most fundamental and direct hardware settings and controls for the computer.

G

GPU

A GPU is one of the most important components of a server. It is used to convert digital signals from the server into analog signals, which are then displayed on a monitor. Additionally, a GPU has image processing capabilities and can assist CPUs in tasks, thereby enhancing the overall operational speed of the server.

H

HDM

Hardware Device Management (HDM) is a control unit used for server management. Through HDM, you can simplify the server configuration process, view server component information, monitor server operation status, and remotely control the server, among other functions.

Hot swapping

Hot swapping capability refers to the ability to remove or install a component in a server while the server is running, without the need to power down the server. This operation does not disrupt the running system and avoids any impact on its operation.

K

KVM device

A Keyboard, Video, Mouse (KVM) device is a physical device that allows you to monitor and manage multiple servers using a single set of keyboard, display, and mouse.

N

Network adapter

A network adapter is a network component that operates at the data link layer. It not only establishes a physical connection and electrical signal matching between the LAN transmission media but also provides functions such as frame transmission and reception, frame encapsulation and decapsulation, medium access control, data encoding and decoding, and data caching.

NVMe VROC module

An NVMe VROC module is used to activate the RAID features of NVMe SSDs. It works in conjunction with the VMD technology to enable NVMe drive array functionality.

R

RAID

Redundant Array of Independent Disks (RAID) is a technology used for combining multiple independent physical drives in different ways to create a disk array, providing higher storage performance and data security than a single drive.

Redundancy

Redundancy means that when a component, such as a fan, fails, the system can automatically utilize a backup component to replace the failed one.

 


Acronyms

Acronym

Full name

B

BIOS

Basic Input/Output System

C

CPU

Central Processing Unit

D

DDR

Double Data Rate

DIMM

Dual In-Line Memory Module

DRAM

Dynamic Random Access Memory

G

GPU

Graphics Processing Unit

H

HBA

Host Bus Adapter

HDD

Hard Disk Drive

HDM

Hardware Device Management

I

ICM

Interconnect Module

L

LFF

Large Form Factor

LRDIMM

Load Reduced Dual Inline Memory Module

N

NVMe

Non-Volatile Memory Express

O

OM

Onboard Management

P

PCIe

Peripheral Component Interconnect Express

R

RAID

Redundant Arrays of Independent Disks

RDIMM

Registered Dual Inline Memory Module

S

SAS

Serial Attached Small Computer System Interface

SATA

Serial ATA

SFF

Small Form Factor

SSD

Solid State Drive

SST

Speed Select Technology

T

TCM

Trusted Cryptography Module

TDP

Thermal Design Power

TPM

Trusted Platform Module

U

UID

Unit Identification

UPI

Ultra Path Interconnect

USB

Universal Serial Bus

V

VROC

Virtual RAID on CPU

VMD

Volume Management Device

 

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网