01-Fundamentals Command Reference

HomeSupportRouters5G IPRAN Access RoutersReference GuidesCommand ReferencesH3C RA5300 Router Command Reference-R7607-6W10001-Fundamentals Command Reference
08-Device management commands
Title Size Download
08-Device management commands 384.38 KB

Contents

Device management commands· 1

clock datetime· 1

clock protocol 2

clock summer-time· 3

clock timezone· 4

command· 5

copyright-info enable· 6

display alarm·· 7

display alarm active· 7

display alarm history· 9

display clock· 10

display copyright 10

display cpu-usage· 11

display cpu-usage configuration· 12

display cpu-usage history· 13

display device· 15

display device manuinfo· 15

display device manuinfo chassis-only· 16

display device manuinfo fan· 17

display device manuinfo power 17

display diagnostic-information· 18

display dying-gasp host 20

display environment 21

display fan· 22

display hardware-failure-detection· 23

display health· 24

display kernel memory alloc-failure· 24

display kernel memory fragment free· 25

display memory· 26

display memory dma· 28

display memory-threshold· 28

display memory-threshold dma· 30

display power 30

display power-supply· 32

display process memory alloc-failure· 32

display scheduler job· 33

display scheduler logfile· 34

display scheduler reboot 34

display scheduler schedule· 35

display system stable state· 36

display transceiver alarm·· 38

display transceiver diagnosis· 39

display transceiver interface· 40

display transceiver manuinfo· 41

display version· 42

display version-update-record· 42

display voltage· 43

dying-gasp host 44

dying-gasp source· 45

header 46

job· 46

memory-threshold· 47

memory-threshold dma· 48

memory-threshold usage· 49

memory-threshold usage resend-interval 50

monitor cpu-usage enable· 51

monitor cpu-usage interval 52

monitor cpu-usage threshold· 52

monitor kernel memory fragment interval 53

monitor kernel memory fragment ratio· 54

monitor resend cpu-usage· 55

monitor resend cpu-usage core-interval 56

monitor resend memory-threshold· 57

monitor resend memory-threshold dma· 58

password-recovery enable· 58

reboot 59

reset scheduler logfile· 60

reset version-update-record· 61

restore factory-default 61

scheduler job· 62

scheduler logfile size· 62

scheduler reboot at 63

scheduler reboot delay· 64

scheduler schedule· 65

shutdown-interval 66

sysname· 66

time at 67

time once· 68

time repeating· 69

user-role· 71


Device management commands

clock datetime

Use clock datetime to set the system time.

Syntax

clock datetime time date

Default

The system time is UTC time 09:00:00 12/07/2013.

Views

User view

Predefined user roles

network-admin

Parameters

time: Specifies a time in the hh:mm:ss format. The value range for hh is 0 to 23. The value range for mm is 0 to 59. The value range for ss is 0 to 59. The leading zero in a segment can be omitted. If the seconds segment is 0 (hh:mm:00), you can omit it. If both the minutes and seconds segments are 0 (hh:00:00), you can omit both of the segments. For example, to specify 08:00:00, you can enter 8.

date: Specifies a date in the MM/DD/YYYY or YYYY/MM/DD format. The value range for YYYY is 2000 to 2035. The value range for MM is 1 to 12. The value range for DD varies by month.

Usage guidelines

CAUTION

CAUTION:

This command changes the system time, which affects the execution of system time-related features (for example, scheduled tasks) and collaborative operations of the device with other devices (for example, log reporting and statistics collection). Before executing this command, make sure you fully understand its impact on your live network.

 

Correct system time is essential to network management and communication. You must configure the system time correctly before you run the device on the network.

For the device to use the local system time, execute the clock protocol none command and this command in turn. The specified system time takes effect immediately. Then, the device uses the clock signals generated by its built-in crystal oscillator to maintain the system time.

If you set the time zone or daylight saving time after you execute this command, the device recalculates the system time. To view the system time, use the display clock command.

If the device does not have an RTC battery, a device power cycling operation restores the local system time to the default. You must execute this command again to set the local system time.

Examples

# Set the system time to 08:08:08 01/01/2012.

<Sysname> clock datetime 8:8:8 1/1/2012

# Set the system time to 08:10:00 01/01/2012.

<Sysname> clock datetime 8:10 2012/1/1

Related commands

clock protocol

clock summer-time

clock timezone

display clock

clock protocol

Use clock protocol to specify the system time source.

Use undo clock protocol to restore the default.

Syntax

clock protocol { none | ntp | ptp } }

undo clock protocol

Default

The device uses NTP to obtain the time.

Views

System view

Predefined user roles

network-admin

Parameters

none: Uses the system time set by using the clock datetime command.

ptp: Uses PTP to obtain the UTC time. You must configure PTP correctly. For more information about PTP and PTP configuration, see Network Management and Monitoring Configuration Guide.

ntp: Uses NTP to obtain the UTC time. You must configure NTP correctly. For more information about NTP and NTP configuration, see Network Management and Monitoring Configuration Guide.

Usage guidelines

Correct system time is essential to network management and communication. You must configure the system time correctly before you run the device on the network.

The device can use the locally set system time, or obtain the UTC time from a time source on the network and calculate the system time.

·     If you execute the clock protocol none command, the device uses the locally set system time. The device then uses the clock signals generated by its built-in crystal oscillator to maintain the system time.

·     If you execute the clock protocol { ntp | ptp } command, the device obtains the UTC time through NTP or PTP and calculates the system time. The device then periodically synchronizes the UTC time and recalculates the system time.

The system time calculated by using the UTC time from an NTP or PTP time source is more precise.

If you execute this command multiple times, the most recent configuration takes effect.

If you set the time zone or daylight saving time after you execute this command, the device recalculates the system time. To view the system time, use the display clock command.

Examples

# Configure the device to use the local system time.

<Sysname> system-view

[Sysname] clock protocol none

clock summer-time

Use clock summer-time to set the daylight saving time.

Use undo clock summer-time to restore the default.

Syntax

clock summer-time name start-time start-date end-time end-date add-time

undo clock summer-time

Default

The daylight saving time is not set.

Views

System view

Predefined user roles

network-admin

Parameters

name: Specifies a name for the daylight saving time schedule, a case-sensitive string of 1 to 32 characters.

start-time: Specifies the start time in the hh:mm:ss format. The value range for hh is 0 to 23. The value range for mm is 0 to 59. The value range for ss is 0 to 59. The leading zero in a segment can be omitted. If the seconds segment is 0 (hh:mm:00), you can omit it. If both the minutes and seconds segments are 0 (hh:00:00), you can omit both of the segments. For example, to specify 08:00:00, you can enter 8.

start-date: Specifies the start date in one of the following formats:

·     MM/DD. The value range for MM is 1 to 12. The value range for DD varies by month.

·     month week day, where:

¡     month—Takes January, February, March, April, May, June, July, August, September, October, November, or December.

¡     week—Represents week of the month. It takes first, second, third, fourth, fifth, or last.

¡     day—Takes Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, or Saturday.

end-time: Specifies the end time in the hh:mm:ss format. The value range for hh is 0 to 23. The value range for mm is 0 to 59. The value range for ss is 0 to 59. The leading zero in a segment can be omitted. If the seconds segment is 0 (hh:mm:00), you can omit it. If both the minutes and seconds segments are 0 (hh:00:00), you can omit both of the segments. For example, to specify 08:00:00, you can enter 8.

end-date: Specifies the end date in one of the following formats:

·     MM/DD. The value range for MM is 1 to 12. The value range for DD varies by month.

·     month week day, where:

¡     month—Takes January, February, March, April, May, June, July, August, September, October, November or December.

¡     week—Represents week of the month. It takes first, second, third, fourth, fifth, or last.

¡     day—Takes Sunday, Monday, Tuesday, Wednesday, Thursday, Friday, or Saturday.

add-time: Specifies the time to be added to the standard time, in the hh:mm:ss format. The value range for hh is 0 to 23. The value range for mm is 0 to 59. The value range for ss is 0 to 59. The leading zero in a segment can be omitted. If the seconds segment is 0 (hh:mm:00), you can omit it. If both the minutes and seconds segments are 0 (hh:00:00), you can omit both of the segments. For example, to specify 08:00:00, you can enter 8.

Usage guidelines

Correct system time is essential to network management and communication. You must configure the system time correctly before you run the device on the network.

After you set the daylight saving time, the device recalculates the system time. To view the system time, use the display clock command.

Make sure all devices on the network are using the same daylight saving time as the local time.

Examples

# Set the system time ahead 1 hour for the period between 06:00:00 on 08/01 and 06:00:00 on 09/01.

<Sysname> system-view

[Sysname] clock summer-time PDT 6 08/01 6 09/01 1

Related commands

clock datetime

clock timezone

display clock

clock timezone

Use clock timezone to set the time zone.

Use undo clock timezone to restore the default.

Syntax

clock timezone zone-name { add | minus } zone-offset

undo clock timezone

Default

The UTC time zone is used.

Views

System view

Predefined user roles

network-admin

Parameters

zone-name: Specifies a time zone by its name, a case-sensitive string of 1 to 32 characters.

add: Adds an offset to the UTC time or local system time.

minus: Decreases the UTC time or local system time by an offset.

zone-offset: Specifies the offset in the hh:mm:ss format. The value range for hh is 0 to 23. The value range for mm is 0 to 59. The value range for ss is 0 to 59. The leading zero in a segment can be omitted. If the seconds segment is 0 (hh:mm:00), you can omit it. If both the minutes and seconds segments are 0 (hh:00:00), you can omit both of the segments. For example, to specify 08:00:00, you can enter 8.

Usage guidelines

Correct system time is essential to network management and communication. You must configure the system time correctly before you run the device on the network.

After you set the time zone, the device recalculates the system time. To view the system time, use the display clock command.

Make sure all devices on the network are using the same time zone as the local time.

Examples

# Set the name of the time zone to Z5, and add 5 hours to the UTC time or local system time.

<Sysname> system-view

[Sysname] clock timezone Z5 add 5

Related commands

clock datetime

clock summer-time

display clock

command

Use command to assign a command to a job.

Use undo command to revoke a command.

Syntax

command id command

undo command id

Default

No command is assigned to a job.

Views

Job view

Predefined user roles

network-admin

Parameters

id: Specifies an ID for the command, in the range of 0 to 4294967295. A command ID uniquely identifies a command in a job. Commands in a job are executed in ascending order of their command IDs.

command: Specifies the command to be assigned to the job.

Usage guidelines

To assign a command (command A) to a job, you must first assign the job the command or commands for entering the view of command A.

If you specify the ID of an existing command for another command, the existing command is replaced.

Make sure all commands in a schedule are compliant to the command syntax. The system does not examine the syntax when you assign a command to a job.

If a command requires a yes or no answer, the system always assumes that a Y or Yes is entered. If a command requires a character string input, the system assumes that either the default character string (if any) or a null string is entered.

A job cannot contain the telnet, ftp, ssh2, or monitor process command.

Examples

# Assign commands to the backupconfig job to back up the startup.cfg file to the TFTP server at 192.168.100.11.

<Sysname> system-view

[Sysname] scheduler job backupconfig

[Sysname-job-backupconfig] command 2 tftp 192.168.100.11 put flash:/startup.cfg backup.cfg

# Assign commands to the shutdownGE job to shut down Ten-GigabitEthernet 2/0/0.

<Sysname> system-view

[Sysname] scheduler job shutdownGE

[Sysname-job-shutdownGE] command 1 system-view

[Sysname-job-shutdownGE] command 2 interface ten-gigabitethernet 2/0/0

[Sysname-job-shutdownGE] command 3 shutdown

Related commands

scheduler job

copyright-info enable

Use copyright-info enable to enable copyright statement display.

Use undo copyright-info enable to disable copyright statement display.

Syntax

copyright-info enable

undo copyright-info enable

Default

Copyright statement display is enabled.

Views

System view

Predefined user roles

network-admin

Examples

# Enable copyright statement display.

<Sysname> system-view

[Sysname] copyright-info enable

The device will display the following statement when a user logs in:

******************************************************************************

* Copyright (c) 2004-2017 New H3C Technologies Co., Ltd. All rights reserved.*

* Without the owner's prior written consent,                                 *

* no decompiling or reverse-engineering shall be allowed.                    *

****************************************************************************** 

display alarm

Use display alarm to display alarm information.

Syntax

display alarm [ slot slot-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays alarm information for all cards.

Usage guidelines

If a power module, CPU, or fan is operating abnormally on the device, you can use the display alarm command to view the alarm information. To view historical alarms that have been cleared, use the display alarm history command. To view active alarms that were generated in the past and have not been cleared on the device, use the display alarm active command.

Examples

# Display alarm information.

<Sysname> display alarm

Slot CPU Level   Info

1    0   ERROR   faulty

Table 1 Command output

Field

Description

Slot

Slot that generated the alarm. If the alarm was generated by the frame, this field displays a hyphen (-).

Level

Alarm severity. Possible values include ERROR, WARNING, NOTICE, and INFO, in descending order.

Info

Detailed alarm information:

·     faulty—The slot is starting up or faulty.

·     Fan n is absent—The specified fan is absent.

·     Power n is absent—The specified power module is absent.

·     The temperature of sensor n exceeds the lower limit—The temperature of the specified sensor is lower than the low-temperature threshold.

·     The temperature of sensor n exceeds the upper limit—The temperature of the specified sensor is higher than the high-temperature warning threshold.

display alarm active

Use display alarm active to display information about active alarms.

Syntax

display alarm active

Views

Any view

Predefined user roles

network-admin

network-operator

Usage guidelines

If a power module, CPU, or fan is operating abnormally on the device, you can use the display alarm command to view the alarm information. To view historical alarms that have been cleared, use the display alarm history command. To view active alarms that were generated in the past and have not been cleared on the device, use the display alarm active command.

Examples

# Display information about active alarms.

<Sysname> display alarm active

Seq    Level    Time                  Info

24     WARNING  2020-01-11  12:40:00  CPU usage is in minor alarm state on slot 1.

23     WARNING  2020-01-11  12:30:00  Memory minor threshold has been exceeded on slot 1.

22     ERROR    2020-01-11  12:18:00  Board state changed to Fault on slot 1.

Table 2 Command output

Field

Description

Seq

Alarm sequence number, assigned when an alarm occurs.

Level

Alarm severity. The values include ERROR, WARNING, NOTICE, and INFO, in descending order of severity.

Time

Time when the alarm occurs.

Info

Detailed alarm information. The values include:

·     Board state changed to Fault on slot n—The state of the specified slot changed to Fault. The slot might be starting up or might be faulty.

·     Slot n fan n is absent—The specified fan is absent.

·     Slot n fan n is failed—The specified fan is abnormal.

·     Slot n power n is absent—The specified power module is absent.

·     Slot n power n failed—The specified power module is abnormal.

·     Temperature is higher than the high-temperature alarming threshold on slot n sensor inflow—The temperature of the specified sensor has exceeded the high-temperature warning threshold.

·     Memory minor threshold has been exceeded on slot n—The amount of free memory space on the specified slot has exceeded the minor alarm threshold.

·     CPU usage is in minor alarm state on slot n—The CPU usage on the specified slot has exceeded the minor alarm threshold.

·     Interface-name: RX power is high!—The optical power on the specified interface is too high.

·     Interface-name:The bit error ratio exceeds the upper threshold—The bit error rate of the specified interface has exceeded the upper limit.

Related commands

display alarm

display alarm history

display alarm history

Use display alarm history to display information about historical alarms that have been cleared.

Syntax

display alarm history [ verbose ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

verbose: Displays detailed information. If you do not specify this keyword, this command displays brief information.

Usage guidelines

If a power module, CPU, or fan is operating abnormally on the device, use the display alarm command to view the alarm information. To view historical alarms that have been cleared, use the display alarm history command. To view active alarms that were generated in the past and have not been cleared on the device, use the display alarm active command.

Examples

# Display brief information about historical alarms.

<Sysname> display alarm history

Seq        Time                  Info

23         2020-01-11 12:40:00 CPU usage recovered to normal state on slot 1.

For information about the fields in the command output, see Table 2.

# Display detailed information about historical alarms.

<Sysname> display alarm history verbose

Seq 23

Alarm name: CPUUsageMinor

Alarm position: slot 1

Start time: 2020-01-11 12:30:00

Level: WARNING

Info: CPU usage is in minor alarm state on slot 1

Recovery time: 2020-01-11 12:40:30

Info: CPU usage minor alarm removed on slot 1.

Table 3 Command output

Field

Description

Seq

Alarm sequence number, assigned automatically by the system when an alarm occurs.

AlarmPosition

Location where the alarm occurs.

Start time

Time when the alarm occurs.

Level

Alarm severity. The values include ERROR, WARNING, NOTICE, and INFO, in descending order of severity.

Recovery time

Time when an alarm is cleared.

Info

Detailed alarm information.

Related commands

display alarm

display alarm active

display clock

Use display clock to display the system time, date, time zone, and daylight saving time.

Syntax

display clock

Views

Any view

Predefined user roles

network-admin

network-operator

Examples

# Display the system time and date when the time zone is not specified.

<Sysname> display clock

10:09:00 UTC Fri 03/16/2015

The time is in the hour:minute:second.milliseconds format.

# Display the system time and date when the time zone Z5 is specified.

<Sysname> display clock

15:10:00 Z5 Fri 03/16/2015

Time Zone : Z5 add 05:00:00

# Display the system time and date when the time zone Z5 and daylight saving time PDT are specified.

<Sysname> display clock

15:11:00 Z5 Fri 03/16/2015

Time Zone : Z5 add 05:00:00

Summer Time : PDT 06:00:00 08/01 06:00:00 09/01 01:00:00

Related commands

clock datetime

clock timezone

clock summer-time

display copyright

Use display copyright to display the copyright statement.

Syntax

display copyright

Views

Any view

Predefined user roles

network-admin

network-operator

Examples

# Display the copyright statement.

<Sysname> display copyright

...

display cpu-usage

 

Use display cpu-usage to display the current CPU usage statistics.

Syntax

display cpu-usage [ summary ] [ slot slot-number [ cpu cpu-number [ core { core-number | all } ] ] ]

display cpu-usage [ control-plane | data-plane ] [ summary ] [ slot slot-number [ cpu cpu-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

control-plane: Displays CPU usage statistics for the control plane.

data-plane: Displays CPU usage statistics for the data plane.

summary: Displays CPU usage statistics in table form. If you do not specify this keyword, the command displays CPU usage statistics in text form.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays the CPU usage statistics for all cards.

cpu cpu-number: Specifies a CPU by its number.

core core-number: Specifies a CPU core by its number.

core all: Specifies all CPU cores.

Usage guidelines

If you do not specify the control-plane or data-plane keyword, the command displays the total CPU usage statistics for the control plane.

If two hyphens (--) are displayed for the CPU usage during the most recent 5-second, 1-minute, and 5-minute intervals, the command might fail to obtain data from the database on the device. Try the command later.

Examples

# Display the current CPU usage statistics in text form.

<Sysname> display cpu-usage

Slot 1 CPU 0 CPU usage:

       1% in last 5 seconds

       1% in last 1 minute

       1% in last 5 minutes

# Display the current CPU usage statistics in table form.

<Sysname> display cpu-usage summary

Slot CPU        Last 5 sec        Last 1 min        Last 5 min

1    0          17%               29%               28%

Table 4 Command output

Field

Description

x% in last 5 seconds

Last 5 sec

Average CPU or CPU core usage during the most recent 5-second interval.

y% in last 1 minute

Last 1 min

Average CPU or CPU core usage during the most recent 1-minute interval.

z% in last 5 minutes

Last 5 min

Average CPU or CPU core usage during the most recent 5-minute interval.

display cpu-usage configuration

Use display cpu-usage configuration to display CPU usage monitoring settings.

Syntax

display cpu-usage configuration [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays the CPU usage monitoring settings for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display the CPU usage monitoring settings.

<Sysname> display cpu-usage configuration

CPU usage monitor is enabled.

Current monitor interval is 60 seconds.

Current severe alarm threshold is 90%.

Current minor alarm threshold is 80%.

Table 5 Command output

Field

Description

CPU usage monitor is xxx.

Whether CPU usage tracking is enabled.

Current monitor interval is xxx.

Sampling interval for CPU usage tracking.

Current severe alarm threshold is xxx.

Severe CPU usage alarm threshold.

Current minor alarm threshold is xxx.

Minor CPU usage alarm threshold.

Related commands

monitor cpu-usage enable

monitor cpu-usage interval

monitor cpu-usage threshold

display cpu-usage history

Use display cpu-usage history to display the historical CPU usage statistics in a coordinate system.

Syntax

display cpu-usage history [ job job-id ] [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

job job-id: Specifies a process by its ID in the range of 1 to 2147483647. If you do not specify a process, this command displays the statistics for the entire system's CPU usage (the total CPU usage of all processes). To view the IDs and names of the running processes, use the display process command. For more information, see Network Management and Monitoring Configuration Guide.

slot slot-number: Specifies a card by its slot number. If you specify a process but do not specify a card, this command displays the statistics for the process on the active MPU. If you do not specify any options, this command displays the statistics for all processes on all cards.

cpu cpu-number: Specifies a CPU by its number. If you specify a process but do not specify a CPU, this command displays the statistics for the default CPU. If you do not specify a process or CPU, this command displays the historical statistics for all CPUs.

Usage guidelines

After CPU usage monitoring is enabled, the system regularly samples CPU usage and saves the samples to the history record buffer. This command displays the most recent 60 samples in a coordinate system as follows:

·     The vertical axis represents the CPU usage. If a statistic is not a multiple of the usage step, it is rounded up or down to the closest multiple of the usage step. For example, if the CPU usage step is 5%, the statistic 53% is rounded up to 55%, and the statistic 52% is rounded down to 50%.

·     The horizontal axis represents the time.

·     Pound signs (#) indicate the CPU usage. The value on the vertical axis for the topmost pound sign at a specific time represents the CPU usage at that time.

Examples

# Display the historical CPU usage statistics.

<Sysname> display cpu-usage history

100%|

 95%|

 90%|

 85%|

 80%|

 75%|

 70%|

 65%|

 60%|

 55%|

 50%|

 45%|

 40%|

 35%|

 30%|

 25%|

 20%|

 15%|             #

 10%|            ###  #

  5%|           ########

     ------------------------------------------------------------

              10        20        30        40        50        60  (minutes)

                      cpu-usage (Slot 1 CPU 0) last 60 minutes (SYSTEM)

The output shows the following items:

·     Process name. The name SYSTEM represents the entire system.

·     CPU that is holding the process: CPU 0 in slot 1.

·     Historical CPU usage statistics for the entire system during the last 60 minutes.

¡     12 minutes ago—Approximately 5%.

¡     13 minutes ago—Approximately 10%.

¡     14 minutes ago—Approximately 15%.

¡     15 minutes ago—Approximately 10%.

¡     16 and 17 minutes ago—Approximately 5%.

¡     18 minutes ago—Approximately 10%.

¡     19 minutes ago—Approximately 5%.

¡     Other time—2% or lower.

Related commands

monitor cpu-usage enable

monitor cpu-usage interval

display device

Use display device to display device information.

Syntax

display device[ slot slot-number | verbose ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards.

verbose: Displays detailed information. If you do not specify this keyword, this command displays brief information, and does not display firewall card information.

Examples

# Display device information.

<Sysname> display device

Slot No.      Board Type                Status        Primary       SubSlots

 ----------------------------------------------------------------------------

 0             RSU-400                   Normal        Master        0

 4             HRIC-GT8                  Normal        N/A           0

 5             HRIC-CLGQ2                Normal        N/A           0

Table 6 Command output

Field

Description

Brd Type

Hardware type of the card.

Status

Card status:

·     Absent—The slot is not installed with a card.

·     Fault—The card is faulty and cannot start up.

·     Normal—The card is an interface card and is operating correctly.

·     Off—The card is not powered on.

·     Illegal—The current software version does not support the card. The card cannot operate correctly.

·     Offline—The card is isolated.

Primary

Card role:

·     Standby—The card is the standby MPU.

·     Master—The card is the active MPU.

 

display device manuinfo

Use display device manuinfo to display electronic label information for the device.

Syntax

display device manuinfo [ slot slot-number [ subslot subslot-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays electronic label information of all cards.

subslot subslot-number: Specifies a subcard by its subslot number. If you do not specify a subcard, this command does not display information about any subcards.

Usage guidelines

An electronic label contains the permanent configuration information, including the hardware serial number, manufacturing date, MAC address, and vendor name. The data is written to the storage component during hardware debugging or testing. This command displays only part of the electronic label information.

Examples

# Display electronic label information for the device.

<Sysname> display device manuinfo

Slot 0 CPU 0:                                                                  

Subslot 0:                                                                      

DEVICE_NAME          : RA5300-X                                                

DEVICE_SERIAL_NUMBER : 210235A2PXA197000001                                    

MAC_ADDRESS          : 600B-0353-0400                                          

MANUFACTURING_DATE   : 2020-09-21                                              

VENDOR_NAME          : H3C                                                     

PRODUCT ID           : RA5300-X     

Table 7 Command output

Field

Description

DEVICE_NAME

Device name.

DEVICE_SERIAL_NUMBER

Serial number.

MAC_ADDRESS

MAC address.

MANUFACTURING_DATE

Manufacturing date.

VENDOR_NAME

Vendor name.

display device manuinfo chassis-only

Use display device manuinfo chassis-only to display electronic label information for the backplane.

Syntax

display device manuinfo chassis-only

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

Examples

# Display electronic label information for the backplane.

<Sysname> display device manuinfo chassis-only

Chassis self:

DEVICE_NAME          : backplane

DEVICE_SERIAL_NUMBER : 210235A36L1234567890

MAC_ADDRESS          : NONE

MANUFACTURING_DATE   : 2015-01-20

VENDOR_NAME          : H3C

PRODUCT_ID           : XX-XXXX-XX

display device manuinfo fan

Use display device manuinfo fan to display electronic label information for a fan tray.

Syntax

display device manuinfo fan fan-id

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

fan-id: Specifies a fan tray by its ID.

Examples

# Display electronic label information for a fan tray.

<Sysname> display device manuinfo fan 1

Fan 1:

DEVICE_NAME          : fan

DEVICE_SERIAL_NUMBER : 210235A36L1234567890

MAC_ADDRESS          : NONE

MANUFACTURING_DATE   : 2010-01-20

VENDOR_NAME          : H3C

display device manuinfo power

Use display device manuinfo power to display electronic label information for a power module.

Syntax

display device manuinfo power power-id

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

power-id: Specifies a power module by its ID.

Examples

# Display electronic label information for a power module.

<Sysname> display device manuinfo power 1

Power 1:

DEVICE_NAME          : power

DEVICE_SERIAL_NUMBER : 210235A36L1234567890

MAC_ADDRESS          : NONE

MANUFACTURING_DATE   : 2010-01-20

VENDOR_NAME          : H3C

display diagnostic-information

Use display diagnostic-information to display or save operating information for features and hardware modules.

Syntax

display diagnostic-information [ hardware | infrastructure | l2 | l3 | service ] [ key-info ] [ filename ] [ background ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

background: Saves operating information in the background. If you do not specify this keyword, the system displays or saves operating information in the CLI and you cannot execute other commands during the process. It is time consuming if a large amount of operating information is to be collected. If you specify this keyword, the system saves operating information in the background and users can execute other commands in the CLI during the process.

hardware: Specifies hardware-related operating information.

infrastructure: Specifies operating information for the fundamental features.

l2: Specifies operating information for the Layer 2 features.

l3: Specifies operating information for the Layer 3 features.

service: Specifies operating information for Layer 4 and upper-layer features.

key-info: Displays or saves only critical operating information. The device might have a large amount of operating information if an exception occurs or after the device runs a long period of time. Specifying this keyword reduces the command execution time and helps you focus on critical operating information. If you do not specify this keyword, the command displays or saves both critical and non-critical operating information.

filename: Saves the information to a file. The filename argument must use the .tar.gz suffix. If you do not specify this argument, the command prompts you to choose whether to save the information to a file or display the information.

Usage guidelines

You can use one of the following methods to collect operating statistics for diagnostics and troubleshooting:

·     Use separate display commands to collect operating information feature by feature or module by module.

·     Use the display diagnostic-information command to collect operating information for multiple or all features and hardware modules.

To save storage space, the display diagnostic-information command automatically compresses information before saving information to a file. To view the file content:

1.     Use the tar extract command to extract the file.

2.     Use the gunzip command to decompress the extracted file.

3.     Use the more command to view the content of the decompressed file.

If you abort the display diagnostic-information command, the gunzip command might not be able to decompress the extracted file. To decompress the extracted file, export the extracted file to a PC that is running Linux, and use the gunzip -c command.

If you do not specify any feature parameters, this command displays or saves the operating information for all features and modules.

If you do not specify a file name for the command, the system prompts you to choose whether to display or save the information. If you choose to save the information, the system automatically assigns a file name and displays the file name in brackets. For file name uniqueness, the file name includes the device name and the current system time. If the device name contains any of the following special characters, the system uses an underscore (_) to replace each special character: forward slashes (/), backward slashes (\), colons (:), asterisks (*), question marks (?), less than signs (<), greater than signs (>), and pipeline signs (|). For example, if the device name is A/B, the device name in the file name will be A_B, as in flash:/diag_A_B_20160101-000438.tar.gz.

This command does not support the |, >, or >> option.

While the device is executing this command, do not execute any other commands. Executing other commands might affect the collected operating information.

Examples

# Display the operating information for all features and modules.

<Sysname> display diagnostic-information

Save or display diagnostic information (Y=save, N=display)? [Y/N]:n

===============================================

  ===============display clock===============

14:03:55 UTC Thu 01/05/2012

=================================================

  ===============display version=============== 

...

# Save the operating information for all features and modules to the default file.

<Sysname> display diagnostic-information

Save or display diagnostic information (Y=save, N=display)? [Y/N]:y

Please input the file name(*.tar.gz)[flash:/diag_Sysname_20160101-024601.tar.gz]:

Diagnostic information is outputting to flash:/diag_Sysname_20160101-024601.tar.gz.

Please wait...

Save successfully.

Press Enter when the system prompts you to enter the file name.

# Save the operating information for all features and modules to the test.tar.gz file.

<Sysname> display diagnostic-information test.tar.gz

Diagnostic information is outputting to flash:/test.tar.gz.

Please wait...

Save successfully.

# Save the operating information in the background to the default file.

<Sysname> display diagnostic-information background

Please input the file name (*.tar.gz)[flash:/diag_Sysname_20201215-163501.tar.gz]:

Diagnostic information is outputting to flash:/diag_Sysname_20201215-163501.tar.gz in the background.

Related commands

gunzip

more

tar extract

display dying-gasp host

Use display dying-gasp host to display poweroff alarm destination host settings.

Syntax

display dying-gasp host

Views

Any view

Predefined user roles

network-admin

network-operator

Examples

# Display poweroff alarm destination host settings.

<Sysname> display dying-gasp host

IPv4 address: 1.1.1.0

Message type: SNMP Trap

Securityname: p1

Version: V1

 

IPv4 address: 1.1.1.1

Message type: Syslog

Table 8 Command output

Field

Description

IPv4 address

IPv4 address of the poweroff alarm destination host.

IPv6 address

IPv6 address of the poweroff alarm destination host.

VPN instance

VPN instance to which the poweroff alarm destination host belongs.

Message type

Message types that the poweroff alarm destination host supports:

·     SNMP Trap—SNMP notification.

·     Syslog—Log message.

Securityname

SNMPv1 or SNMPv2c community name.

This field is displayed when the message type is SNMP Trap.

Version

SNMP version:

·     v1—SNMPv1.

·     v2c—SNMPv2c.

This field is displayed when the message type is SNMP Trap.

Related commands

dying-gasp host

display environment

Use display environment to display temperature information.

Syntax

display environment [ slot slot-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards.

Usage guidelines

This command displays information about all temperature sensors on the device if you do not specify a card.

Examples

# Display information about all temperature sensors on the device.

<Sysname> display environment

 System temperature information (degree centigrade):

 -----------------------------------------------------------------------------

 Slot  Sensor       Temperature  Lower       Warning       Alarm       Shutdown

 1     hotspot 1    38           10          40            50          100

 1     hotspot 2    42           10          50            80          100

Table 9 Command output

Field

Description

System Temperature information (degree centigrade)

Temperature information (°C).

sensor

Temperature sensor:

·     hotspot—Hotspot sensor.

·     inflow—Air inlet sensor.

·     outflow—Air outlet sensor.

Slot

Sensor position. For a sensor on the chassis or fan tray, this field displays Vent.

Temperature

Current temperature.

Lower

Lower temperature limit. If the device does not support this field, this field displays NA.

Warning

Warning temperature threshold. If the device does not support this field, this field displays NA.

Alarm

Alarming temperature threshold. If the device does not support this field, this field displays NA.

Shutdown

Shutdown temperature threshold. When the sensor temperature reaches the limit, the system shuts down automatically. If the device does not support this field, this field displays NA.

display fan

Use display fan to display fan tray operating status information.

Syntax

display fan [ fan-id ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

fan-id: Specifies a fan tray by its ID. If you do not specify a fan tray, this command displays operating status information for all fan trays at the specified position.

Examples

# Display the operating states of all fan trays.

<Sysname> display fan

 Index  Status     Speedlevel

 ----------------------------

 1      Normal     1

Table 10 Command output

Field

Description

Status

Fan status:

·     Absent—The slot is not installed with a fan tray.

·     Fault—The fan is faulty.

·     Normal—The fan is operating correctly.

·     FanDirectionFault—The actual airflow direction is not the preferred direction.

display hardware-failure-detection

Use display hardware-failure-detection to display the hardware failure detection settings and the latest 10 fix records for each card.

Syntax

display hardware-failure-detection

Views

Any view

Predefined user roles

network-admin

network-operator

Usage guidelines

The fix records are stored on the active MPU. You can use this command to display the records for a card even if the card is removed or replaced. The fix records are lost only when you remove or power cycle the active MPU.

Examples

# Display hardware failure detection settings and fix records.

<Sysname> display hardware-failure-detection

Current level:

    chip       : isolate

    board      : isolate

    forwarding : warning

Recent record:

--------------------------Slot  0 executed records:-----------------------------

                 There is no record.

--------------------------Slot  0 trapped records:-----------------------------

                 There is no record.

Table 11 Command output

Field

Description

Current level

Fix actions specified for hardware failures.

chip

Fix action for hardware failures on components of cards.

board

Fix action for hardware failures on control paths.

forwarding

Fix action for hardware failures on the forwarding plane.

Recent record

Recent failure fix records.

xxx executed records

Fix records stored on an MPU.

xxx trapped records

Trap records stored on an MPU.

display health

Use display health to display CPU and memory usage.

Syntax

display health [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays CPU and memory usage on all cards.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display the CPU and memory usage on all cards.

<Sysname> display health

Slot CPU Role         CPU Usage(%) Memory Usage(%) Used/Total(MB)

1    0   Master       5            75              1787/7958

2    0   Standby      13           86              2563/7958

Table 12 Command output

Field

Description

Role

Role of the card:

·     MPU(Master)—Active MPU.

·     MPU (Standby)—Standby MPU.

·     LPU—Interface card.

CPU Usage(%)

Average CPU usage during the past 5 seconds, in percentage

Memory Usage(%)

Memory usage in percentage.

Used/Total(MB)

Used memory size and total memory size in MB.

 

display kernel memory alloc-failure

Use display kernel memory alloc-failure to display kernel memory allocation failure information.

Syntax

display kernel memory alloc-failure [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays kernel memory allocation failure information for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display kernel memory allocation failure information.

<System> display kernel memory alloc-failure

kmalloc_tag failures: 55.

kcalloc_tag failures: 0.

kzalloc_tag failures: 0.

krealloc_tag failures: 0.

kmem_cache_alloc_tag failures: 0.

Table 13 Command output

Field

Description

kmalloc_tag failures

Number of memory allocation failures on the use of kmalloc_tag.

kcalloc_tag failures

Number of memory allocation failures on the use of kcalloc_tag.

kzalloc_tag failures

Number of memory allocation failures on the use of kzalloc_tag.

krealloc_tag failures

Number of memory allocation failures on the use of krealloc_tag.

kmem_cache_alloc_tag failures

Number of memory allocation failures on the use of kmem_cache_alloc_tag.

display kernel memory fragment free

Use display kernel memory fragment free to display the kernel memory fragment statistics.

Syntax

display kernel memory fragment free [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays kernel memory fragment statistics for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display the kernel memory fragment statistics.

<Sysname> display kernel memory fragment free

Kernel memory free ratio:  0.13%

cfq_io_context                   memory free (in kbytes): 0

LFIB_NhlfeEntryCache26           memory free (in kbytes): 0

LFIB_NhlfeEntryCache74           memory free (in kbytes): 0

L2VFIB_TUNNELBMP_Cache           memory free (in kbytes): 0

NAT_SESSION_EXT_INFO             memory free (in kbytes): 0

ARP_VSISUP_Entry_cache           memory free (in kbytes): 0

LFIB_NhlfeEntryCache1            memory free (in kbytes): 0

FVN_FwdCache19                   memory free (in kbytes): 0

...

Table 14 Command output

Field

Description

Kernel memory free ratio

Memory fragment ratio in the kernel space.

cfq_io_context                   memory free (in kbytes)

Memory fragment size in the slab named cfq_io_context, in KB.

display memory

Use display memory to display memory usage information.

Syntax

display memory [ summary ] [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

summary: Displays brief information about memory usage. If you do not specify this keyword, the command displays detailed information about memory usage.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays memory usage for all cards.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

If two hyphens (--) are displayed for all the fields in a line of the command output, the command might fail to obtain data from the database on the device. Try the command later.

Examples

# Display detailed memory usage information.

<Sysname> display memory

Memory statistics are measured in KB:

Slot 1:

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:        984560    456128    528432         0         4     45616       53.7%

-/+ Buffers/Cache:    410508    574052

Swap:            0         0         0

LowMem:     739824    375552    364272        --        --        --       49.2%

HighMem:    244736     80576    164160        --        --        --       67.1%

# Display brief memory usage information.

<Sysname> display memory summary

Memory statistics are measured in KB:

Slot CPU        Total      Used      Free  Buffers    Caches FreeRatio

   1   0       984560    456128    528432        4     45616     53.7%

 

Low memory statistics are measured in KB:

Slot CPU        Total      Used      Free  Buffers    Caches FreeRatio

   1   0       739824    375552    364272       --        --     49.2%

 

High memory statistics are measured in KB:

Slot CPU        Total      Used      Free  Buffers    Caches FreeRatio

   1   0       244736     80576    164160       --        --     67.1%   

Table 15 Command output

Field

Description

Mem

Memory usage information.

Total

Total size of the physical memory space that can be allocated.

The memory space is virtually divided into two parts. Part 1 is solely used for kernel code, kernel management, and ISSU functions. Part 2 can be allocated and used for such tasks as running service modules and storing files. The size of part 2 equals the total size minus the size of part 1.

Used

Used physical memory.

Free

Free physical memory.

Shared

Physical memory shared by processes.

If this field is not supported, two hyphens (--) are displayed.

Buffers

Physical memory used for buffers.

If this field is not supported, two hyphens (--) are displayed.

Cached

Caches

Physical memory used for caches.

If this field is not supported, two hyphens (--) are displayed.

FreeRatio

Free memory ratio.

-/+ Buffers/Cache

-/+ Buffers/Cache:used = Mem:Used – Mem:Buffers – Mem:Cached, which indicates the physical memory used by applications.

-/+ Buffers/Cache:free = Mem:Free + Mem:Buffers + Mem:Cached, which indicates the physical memory available for applications.

Swap

Memory space for swapping.

LowMem

Low-memory usage information.

HighMem

High-memory usage information.

display memory dma

Use display memory dma to display DMA memory usage information.

Syntax

display memory dma [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays DMA memory usage information for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display DMA memory usage information for slot 1.

<System> display memory dma slot 1

DMA memory statistics measured in KB on slot 1:

Total        Used         Free         FreeRatio

16384        6140         10244        63%

Table 16 Command output

Field

Description

Total

Total size of the DMA memory space, including the free and used DMA memory.

Used

Used DMA memory.

Free

Free DMA memory.

FreeRatio

Free DMA memory ratio.

display memory-threshold

Use display memory-threshold to display memory alarm thresholds and statistics.

Syntax

display memory-threshold [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays the memory usage thresholds and statistics for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

For more information about memory usage notifications, see log information containing MEM_EXCEED_THRESHOLD or MEM_BELOW_THRESHOLD.

Examples

# Display memory alarm thresholds and statistics.

<Sysname> display memory-threshold

Memory usage threshold: 100%

Free-memory thresholds:

    Minor: 256M

    Severe: 128M

    Critical: 64M

    Normal: 304M

 

 [Back to normal state]

    First notification: 0.0

    Latest notification: 0.0

    Total number of notifications sent: 0

 [Entered minor alarm state]

    First notification at: 0.0

    Latest notification at: 0.0

    Total number of notifications sent: 0

 [Back to minor alarm state]

    First notification at: 0.0

    Latest notification at: 0.0

    Total number of notifications sent: 0

 [Entered severe alarm state]

    First notification at: 0.0

    Latest notification at: 0.0

    Total number of notifications sent: 0

 [Back to severe alarm state]

    First notification at: 0.0

    Latest notification at: 0.0

    Total number of notifications sent: 0

 [Entered critical alarm state]

    First notification at: 0.0

    Latest notification at: 0.0

    Total number of notifications sent: 0

Table 17 Command output

Field

Description

Free-memory thresholds

    Minor

    Severe

    Critical

    Normal

Free-memory thresholds, including:

·     Minor—Minor alarm threshold in MB.

·     Severe—Severe alarm threshold in MB.

·     Critical—Critical alarm threshold in MB.

·     Normal—Normal state threshold in MB.

Current free-memory state

Current state of the free memory in the system:

·     Normal—Normal state.

·     Minor—Minor alarm threshold.

·     Severe—Severe alarm threshold.

·     Critical—Critical alarm threshold.

display memory-threshold dma

Use display memory-threshold dma to display DMA memory alarm information.

Syntax

display memory-threshold dma [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays DMA memory alarm information for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display DMA memory alarm information.

<Sysname> display memory-threshold dma

Free DMA memory thresholds:

    Critical: 2048KB

    Normal: 4096KB

Current DMA memory state: Normal

Free memory event statistics:

 [Back to normal state]

    First notification: 0.0

    Latest notification: 0.0

    Total number of notifications sent: 0

 [Entered to critcal state]

    First notificatio: 0.0

    Latest notification: 0.0

    Total number of notifications sent: 0

display power

Use display power to display power module information.

Syntax

display power [ power-id | verbose ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

power-id: Specifies a power module by its ID. If you do not specify a power module, this command displays information about all power modules at the specified position.

verbose: Displays detailed information. If you do not specify this keyword, the command displays brief information.

Examples

# Display brief power supply information.

<Sysname> display power

  Index          Status

  ----------------------

  PWR1           absent

  PWR2           normal

Table 18 Command output

Field

Description

Status

Power supply status.

·     absent—The slot is not installed with a power supply.

·     fail—The power supply is faulty.

·     normal—The power supply is operating correctly.

# Display detailed power module information.

<Sysname> display power verbose

System power information:

Power modules installed: 1

Power modules usable: 1

Rated power: 2000 W

Usable power: 1495 W

Used power: 139.60 W

Redundant power: 0 W

Total DC output : 2.8 A

 

PowerID    State   InVoltage(V) InPower(W)  OutVoltage(V) OutCurrent(A)  OutPower(W)

1          Normal  220          2000        50            2.8            140

2          Absent  --           --          --            --             --

 

Power information by slot:

Slot  Type   Current(A)   Power(W)  Status

1     None   5            10        Normal

Table 19 Command output

Field

Description

Index

Power supply ID.

Status

Power supply status:

·     Absent—The slot is not installed with a power supply.

·     Fault—The power supply is faulty.

·     Normal—The power supply is operating correctly.

Type

Power supply type:

·     AC—AC power supply.

·     DC—DC power supply.

Description

Description of the power supply.

display power-supply

Use display power-supply to display power supply management information.

Syntax

display power-supply [ verbose ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

verbose: Displays detailed power supply management information. If you do not specify this keyword, this command displays the brief information.

Examples

# Display power supply management information.

<Sysname> display power-supply

Index          Status          Type            Description                   

  -----------------------------------------------------------                  

PWR1           Normal          DC              48V DC Power                  

PWR2           Absent          DC              48V DC Power

display process memory alloc-failure

Use display process memory alloc-failure to display memory allocation failure information for a process in the user space.

Syntax

display process memory alloc-failure job job-id [ slot slot-number [ cpu cpu-number ] ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

job job-id: Specifies a process by its ID in the range of 1 to 2147483647. A job ID uniquely identifies a process and does not change after a process reboot.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays memory allocation failure information for a process on the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Examples

# Display memory allocation failure information for processor job 1 in the user space.

<System> display process memory alloc-failure job 1

32-byte alloc failures: 10

64-byte alloc failures:

128-byte alloc failures: 1

---- More ----

display scheduler job

Use display scheduler job to display job configuration information.

Syntax

display scheduler job [ job-name ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

job-name: Specifies a job by its name, a case-sensitive string of 1 to 47 characters. If you do not specify a job, this command displays configuration information for all jobs.

Examples

# Display configuration information for all jobs.

<Sysname> display scheduler job

Job name: saveconfig

 copy startup.cfg backup.cfg

 

Job name: backupconfig

 

Job name: 123

// The output shows that the device has three jobs: the first has one command, the second does not have any commands, and the third has two commands. Jobs are separated by blank lines.

display scheduler logfile

Use display scheduler logfile to display job execution log information.

Syntax

display scheduler logfile

Views

Any view

Predefined user roles

network-admin

network-operator

Examples

# Display job execution log information.

<Sysname> display scheduler logfile

Logfile Size: 1902 Bytes.

 

Job name        : shutdown

Schedule name   : shutdown

Execution time  : Tue Dec 27 10:44:42 2011

Completion time : Tue Dec 27 10:44:47 2011

--------------------------------- Job output -----------------------------------

<Sysname>system-view

System View: return to User View with Ctrl+Z.

[Sysname]interface rang ten-gigabitethernet 2/0/0 to ten-gigabitethernet 2/0/2

[Sysname-if-range]shutdown

Table 20 Command output

Field

Description

Logfile Size

Size of the log file, in bytes.

Schedule name

Schedule to which the job belongs.

Execution time

Time when the job was started.

Completion time

Time when the job was completed. If the job has never been executed or the job does not have any commands, this field is blank.

Job output

Commands in the job and their output.

Related commands

reset scheduler logfile

display scheduler reboot

Use display scheduler reboot to display the automatic reboot schedule.

Syntax

display scheduler reboot

Views

Any view

Predefined user roles

network-admin

network-operator

Examples

# Display the automatic reboot schedule.

<Sysname> display scheduler reboot

System will reboot at 16:32:00 05/23/2011 (in 1 hours and 39 minutes).

Related commands

scheduler reboot at

scheduler reboot delay

display scheduler schedule

Use display scheduler schedule to display schedule information.

Syntax

display scheduler schedule [ schedule-name ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

schedule-name: Specifies a schedule by its name, a case-sensitive string of 1 to 47 characters. If you do not specify a schedule, this command displays information about all schedules.

Examples

# Display information about all schedules.

<Sysname> display scheduler schedule

Schedule name        : shutdown

Schedule type        : Run once after 0 hours 2 minutes

Start time           : Tue Dec 27 10:44:42 2011

Last execution time  : Tue Dec 27 10:44:42 2011

Last completion time : Tue Dec 27 10:44:47 2011

Execution counts     : 1

-----------------------------------------------------------------------

Job name                                          Last execution status

shutdown                                          Successful

Table 21 Command output

Field

Description

Schedule type

Execution time setting of the schedule. If no execution time is specified, this field is not displayed.

Start time

Time to execute the schedule for the first time. If no execution time is specified, this field is not displayed.

Last execution time

Last time when the schedule was executed. If no execution time is specified, this field is not displayed. If the schedule has never been executed, "Yet to be executed" is displayed for this field.

Last completion time

Last time when the schedule was completed. If no execution time is specified, this field is not displayed.

Execution counts

Number of times the schedule has been executed. If the schedule has never been executed, this field is not displayed.

Job name

Name of a job under the schedule.

Last execution status

Result of the most recent execution:

·     Successful.

·     Failed.

·     Waiting—The device is executing the schedule and the job is waiting to be executed.

·     In process—The job is being executed.

·     -NA-—The execution time has not arrived yet.

To view information about whether the commands in the job has been executed and the execution results, execute the display scheduler logfile command.

display system stable state

Use display system stable state to display system stability and status information.

Syntax

display system stable state[ summary ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

summary: Displays brief information about system stability and status, including system status, redundancy status, and NSR status. If you do not specify this keyword, the command displays detailed information about system status, redundancy status, and CPU role and status.

Usage guidelines

Before performing an ISSU or a switchover, execute this command multiple times to identify whether the system is operating stably. If the value of the System State field is not Stable, you cannot perform an ISSU. If the value of the Redundancy State field is not Stable, you cannot perform a switchover.

The device startup process takes some time. If the values of the status fields do not change to Stable, execute this command multiple times to identify the devices that are not in Stable state. You can also use other commands to identify the faulty components. For example:

·     Use the display device command to identify the device operating status.

·     Use the display ha service-group command to display the status of HA service groups and identify the groups in batch backup state.

·     Use the display system internal process state command in probe view to display service operating status.

Examples

# Display brief information about system stability and status.

<Sysname> display system stable state summary

System state      : Stable

Redundancy state  : No redundance

NSR     state     : No standby

# Display system stability and status information.

<Sysname> display system stable state

System state     : Stable

Redundancy state : Stable

  Slot    CPU    Role       State

  0       0      Active     Stable

Table 22 Command output

Field

Description

System state

Operating status of all cards:

·     Stable—All cards are operating stably.

·     Not ready—One or more cards are not operating stably.

Redundancy state

System redundancy status:

·     Stable—Both MPUs are operating stably. You can perform a switchover.

·     No redundance—The system has only one MPU. You cannot perform a switchover.

·     Not ready—The system is not operating stably. You cannot perform a switchover.

Role

Role of the card in the system:

·     Active—The card is the active MPU.

·     Standby—The card is the standby MPU.

·     Other—The card is a service module.

State

Operating status of the card:

·     Stable—The card is operating stably.

·     Board inserted—The card has just been installed.

·     Kernel initiating—Card kernel is being initialized.

·     Service starting—Services are starting.

·     Service stopping—Services are stopping.

·     HA batch backup—An HA batch backup is going on.

·     Interface data batch backup—An interface data batch backup is in progress.

*

The object is not operating stably.

Related commands

display device

display ha service-group (High Availability Command Reference)

display transceiver alarm

Use display transceiver alarm to display transceiver alarms.

Syntax

display transceiver alarm interface [ interface-type interface-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no interface is specified, this command displays the alarms present on every transceiver module.

Usage guidelines

Table 23 shows the common transceiver alarm components. If no error occurs, "None" is displayed.

Table 23 Common transceiver alarm components

Field

Description

APD

Avalanche photo diode

PCS

Physical coding sublayer

PHY XS

PHY extended sublayer

PMA/PMD

Physical medium attachment/physical medium dependent

power

Optical power

REFCLK

Reference clock

RX

Receive

TEC

Thermoelectric cooler

Temp

Temperature

TX

Transmit

WIS

WAN interface sublayer

Examples

# Display the alarms present on the transceiver module in interface Ten-GigabitEthernet 2/0/0.

<Sysname> display transceiver alarm interface ten-gigabitethernet 2/0/0

Ten-GigabitEthernet2/0/0 transceiver current alarm information:

  RX signal loss

  RX power low

Table 24 Command output

Field

Description

transceiver current alarm information

Alarms present on the transceiver module.

RX signal loss

Input signal loss occurred.

RX power low

Received power is low.

display transceiver diagnosis

Use display transceiver diagnosis to display the current values of the digital diagnosis parameters on transceiver modules.

Syntax

display transceiver diagnosis interface [ interface-type interface-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no interface is specified, this command displays the current values of the digital diagnosis parameters on every transceiver module.

Examples

# Display the current values of the digital diagnosis parameters on the transceiver module in interface Ten-GigabitEthernet 2/0/0.

<Sysname> display transceiver diagnosis interface ten-gigabitethernet 2/0/0

Ten-GigabitEthernet2/0/0 transceiver diagnostic information:

  Current diagnostic parameters:

    Temp(°C)  Voltage(V)  Bias(mA)  RX power(dBm)  TX power(dBm)

    36        3.31        6.13      -35.64          -5.19

  Alarm thresholds:

           Temp(°C)   Voltage(V)  Bias(mA)  RX power(dBM)  TX power(dBM)

    High   50         3.55        1.44      -10.00         5.00

    Low    30         3.01        1.01      -30.00         0.00

Table 25 Command output

Field

Description

transceiver diagnostic information

Digital diagnosis information for the transceiver module in the interface.

Wave.er(nm)

Wavelength offset in nm, accurate to 0.001 nm. This field is supported only on the HPE X130 10G SFP+ LC LH80 tunable Transceiver (JL250A), SFP-XG-LH80-Tunable, and CFP2-200G-DCO-Tunable transceiver modules.

Freq.er(GHz)

Frequency offset in GHz, accurate to 0.1 GHz. This field is supported only on the HPE X130 10G SFP+ LC LH80 tunable Transceiver (JL250A), SFP-XG-LH80-Tunable, and CFP2-200G-DCO-Tunable transceiver modules.

Temp.(°C)

Temperature in °C, accurate to 1°C.

Voltage(V)

Voltage in V, accurate to 0.01 V.

Bias(mA)

Bias current in mA, accurate to 0.01 mA.

RX power(dBm)

Receive power in dBm, accurate to 0.01 dBm.

TX power(dBm)

Transmit power in dBm, accurate to 0.01 dBm.

display transceiver interface

Use display transceiver interface to display the key parameters of transceiver modules.

Syntax

display transceiver interface [ interface-type interface-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

interface-type interface-number: Specifies an interface by its type and number. If you do not specify an interface, this command displays the key parameters of every transceiver module.

Examples

# Display the key parameters of the transceiver module in interface Ten-GigabitEthernet 2/0/0.

<Sysname> display transceiver interface ten-gigabitethernet 2/0/0

Ten-GigabitEthernet2/0/0 transceiver information:

  Transceiver Type              : 1000_BASE_SX_SFP

  Connector Type                : LC

  Wavelength(nm)                : 850

  Transfer Distance(m)          : 550(50um),275(62.5um)

  Digital Diagnostic Monitoring : YES

  Vendor Name                   : H3C

Table 26 Command output

Field

Description

Connector Type

Connector types:

·     SC—Fiber connector developed by NTT.

·     LC—1.25 mm/RJ-45 fiber connector developed by Lucent.

·     RJ-45.

·     CX 4.

Wavelength(nm)

Central wavelength (in nm) of the transmit laser. If the transceiver supports multiple wavelengths, every two wavelength values are separated by a comma.

For a copper cable, this field displays N/A.

Transfer Distance(xx)

Transmission distance, where xx indicates the distance unit:

·     km—Kilometers, for single-mode transceiver modules.

·     m—Meters, for other transceiver modules.

If the transceiver module supports multiple types of transmission media, this field displays the transmission distance for each type, in the form of transmission distance (medium type).

Transmission medium types include:

·     9 um—9/125 µm single-mode fiber.

·     50 um—50/125 µm OM2 multi-mode fiber.

·     62.5um—62.5/125 um OM1 multi-mode fiber.

·     CX4—CX4 cable.

·     OM3—50 um OM3 multi-mode fiber.

·     OM4—50 um OM4 multi-mode fiber.

·     OM5—50 um OM5 multi-mode fiber.

·     STACK—Stack cable.

·     TP—Twisted pair.

Digital Diagnostic Monitoring

Support for digital diagnosis:

·     YES—Supported.

·     NO—Not supported.

display transceiver manuinfo

Use display transceiver manuinfo to display electronic label information for transceiver modules.

Syntax

display transceiver manuinfo interface [ interface-type interface-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no interface is specified, this command displays electronic label information for all transceiver modules.

Examples

# Display electronic label information for the transceiver module in interface Ten-GigabitEthernet 2/0/0.

<Sysname> display transceiver manuinfo interface ten-gigabitethernet 2/0/0

Ten-GigabitEthernet2/0/0 transceiver manufacture information:

  Manu. Serial Number  : 213410A0000054000251

  Manufacturing Date   : 2012-09-01

  Vendor Name          : H3C

Table 27 Command output

Field

Description

Manu. Serial Number

Serial number generated during production of the transceiver module.

Manufacturing Date

Date when the electronic label information was written to the transceiver module.

display version

Use display version to display system version information.

Syntax

display version

Views

Any view

Predefined user roles

network-admin

network-operator

Examples

# Display system version information.

<Sysname> display version

display version-update-record

Use display version-update-record to display startup software image upgrade records.

Syntax

display version-update-record

Views

Any view

Predefined user roles

network-admin

network-operator

Usage guidelines

The device records its current startup software version information whenever it starts up, and records all software version update information. Such information can survive reboots.

Examples

# Display the startup software image upgrade records.

<Sysname> display version-update-record

Record 1  (updated on Apr 17 2021 at 14:36:44):                                

 *Name        : ra5300xrsu4xx-cmw710-boot-e7725.bin                            

  Version     : 7.1.075 ESS 7725                                               

  Compile time: Mar 22 2021 16:00:00                                           

                                                                                

 *Name        : ra5300xrsu4xx-cmw710-system-e7725.bin                          

  Version     : 7.1.075 ESS 7725                                               

  Compile time: Mar 22 2021 16:00:00                                           

                                                                               

 *Name        : ra5300xrsu4xx-cmw710-devkit-e7725.bin                          

  Version     : 7.1.075 ESS 7725                                                

  Compile time: Mar 22 2021 16:00:00

 

Table 28 Command output

Field

Description

Record n

Number of the startup software image upgrade record. Record 1 is the most recent record.

Name

Software image file name.

*

The software image version changed during the upgrade.

Related commands

reset version-update-record

display voltage

Use display voltage to display voltage information.

Syntax

display voltage [ slot slot-number ]

Views

Any view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number.

Usage guidelines

If you do not specify a card, this command displays voltage information for all cards.

If the voltage is lower than the lower limit or higher than the higher limit, the device sends a log message and a trap.

Examples

# Display voltage information.

<Sysname> display voltage

System voltage information (volt):

------------------------------------------------------------------------------

Slot Sensor Voltage Status Required LowLimit HighLimit Description

1    0      0.763   Normal 0.750    0.675    0.825     0.75

1    1      1.051   Normal 1.050    0.945    1.155     1.05

Table 29 Command output

Field

Description

Sensor

ID of the sensor.

Voltage

Current voltage of the sensor.

Description

Description for the sensor. This field is generated by the device. It displays the rated voltage of the sensor. If another sensor has the same rated voltage value, a string is automatically inserted before the rated voltage value to uniquely identify the item.

dying-gasp host

Use dying-gasp host to configure poweroff alarm destination host settings.

Use undo dying-gasp host to remove poweroff alarm destination host settings.

Syntax

dying-gasp host { ip-address | ipv6 ipv6-address } [ vpn-instance vpn-instance-name ] snmp-trap version { v1 | v2c } securityname security-string

dying-gasp host { ip-address | ipv6 ipv6-address } [ vpn-instance vpn-instance-name ] syslog

undo dying-gasp host { ip-address | ipv6 ipv6-address } [ vpn-instance vpn-instance-name ] { snmp-trap | syslog }

Default

No poweroff alarm destination host settings are configured.

Views

System view

Predefined user roles

network-admin

Parameters

ip-address: Specifies the IPv4 address of the destination host to which the device sends the poweroff alarm.

ipv6 ipv6-address: Specifies the IPv6 address of the destination host to which the device sends the poweroff alarm.

vpn-instance vpn-instance-name: Specifies the MPLS L3VPN instance to which the destination host belongs. The vpn-instance-name argument represents the VPN instance name, a case-sensitive string of 1 to 31 characters. If the destination host belongs to the public network, do not specify this option.

snmp-trap: Uses an SNMP notification to send the poweroff alarm.

version: Specifies the SNMP version.

v1: Uses SNMPv1.

v2c: Uses SNMPv2c.

securityname security-string: Specifies an SNMPv1 or SNMPv2c community name, a case-sensitive string of 1 to 32 characters.

syslog: Uses a log message to send the poweroff alarm.

Usage guidelines

The device can send the poweroff alarm by using either or both of an SNMP notification and a log message.

The device can send the poweroff alarm to multiple destination hosts at the same time.

Examples

# Configure the device to send the poweroff alarm to the host at 1.1.1.1 by using an SNMPv1 notification. The community name is public.

<Sysname> system-view

[Sysname] dying-gasp host 1.1.1.1 snmp-trap version v1 securityname public

Related commands

display dying-gasp host

dying-gasp source

dying-gasp source

Use dying-gasp source to specify the source interface for sending the poweroff alarm.

Use undo dying-gasp source to restore the default.

Syntax

dying-gasp source interface-type { interface-number | interface-number.subnumber }

undo dying-gasp source

Default

No source interface is specified. On an IPv4 network, the device uses the primary IPv4 address of the output interface for the route to the destination host as the source address. On an IPv6 network, the device selects a source IPv6 address as defined in RFC 3484.

Views

System view

Predefined user roles

network-admin

Parameters

interface-type { interface-number | interface-number.subnumber }: Specifies a Layer 3 interface or subinterface. The interface-type argument specifies the interface type. The interface-number argument specifies the interface number. The subnumber argument specifies the subinterface number and is in the range of 1 to 4094.

Usage guidelines

The device uses the IPv6 address or primary IPv4 address of the specified source interface as the source address for outgoing poweroff alarm packets. The destination hosts use this address to identify SNMP notifications or log messages received from the device.

If no address is configured for the specified source interface, this command does not take effect. For this command to take effect, assign an address to the source interface.

Examples

# Use the Loopback 1 interface as the source interface for sending the poweroff alarm.

<Sysname> system-view

[Sysname] dying-gasp source loopback 1

Related commands

dying-gasp host

header

Use header to configure a banner.

Use undo header to delete a banner.

Syntax

header { legal | login | motd | shell } text

undo header { legal | login | motd | shell }

Default

No banner is configured.

Views

System view

Predefined user roles

network-admin

Parameters

legal: Configures the banner to be displayed before a user inputs the username and password to access the CLI.

login: Configures the banner to be displayed before password or scheme authentication is performed for a login user.

motd: Configures the greeting banner to be displayed before the legal banner appears.

shell: Configures the banner to be displayed before a user accesses user view.

text: Specifies the banner message. You can enter the banner message on the same line as the keywords or on different lines. For more information, see Fundamentals Configuration Guide.

Examples

# Configure the legal banner.

<Sysname> system-view

[Sysname] header legal

Please input banner content, and quit with the character '%'.

Welcome to use the legal banner%

job

Use job to assign a job to a schedule.

Use undo job to revoke a job.

Syntax

job job-name

undo job job-name

Default

No job is assigned to a schedule.

Views

Schedule view

Predefined user roles

network-admin

Parameters

job-name: Specifies the job name, a case-sensitive string of 1 to 47 characters.

Usage guidelines

You can assign multiple jobs to a schedule. The jobs in a schedule are executed concurrently.

The jobs to be assigned to a schedule must already exist. To create a job, use the scheduler job command.

Examples

# Assign the save-job job to the saveconfig schedule.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] job save-job

Related commands

scheduler job

scheduler schedule

memory-threshold

Use memory-threshold to set free-memory thresholds.

Use undo memory-threshold to restore the default.

Syntax

memory-threshold [ slot slot-number [ cpu cpu-number ] ] [ ratio ] minor minor-value severe severe-value critical critical-value normal normal-value

undo memory-threshold [ slot slot-number [ cpu cpu-number ] ]

Default

Minor alarm threshold: 96 MB.

Severe alarm threshold: 64 MB.

Critical alarm threshold: 48 MB.

Normal state threshold: 128 MB.

Views

System view

Predefined user roles

network-admin

Parameters

ratio: Specifies free-memory thresholds in percentage. If you do not specify this keyword, the command sets free-memory thresholds in MB.

minor minor-value: Specifies the minor alarm threshold. To view the value range for this threshold, enter a question mark (?) in the place of the minor-value argument. This threshold must be equal to or less than the normal state threshold. Setting this threshold to 0 disables the minor alarm feature.

severe severe-value: Specifies the severe alarm threshold. To view the value range for this threshold, enter a question mark (?) in the place of the severe-value argument. This threshold must be equal to or less than the minor alarm threshold. Setting this threshold to 0 disables the severe alarm feature.

critical critical-value: Specifies the critical alarm threshold. To view the value range for this threshold, enter a question mark (?) in the place of the critical-value argument. This threshold must be equal to or less than the severe alarm threshold. Setting this threshold to 0 disables the critical alarm feature.

normal normal-value: Specifies the normal state threshold. To view the value range for this threshold, enter a question mark (?) in the place of the normal-value argument. This threshold must be equal to or less than the total memory size.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets free-memory thresholds for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

To ensure correct operation and improve memory efficiency, the system monitors the amount of free memory space in real time. If the amount of free memory space decreases to or below the minor, severe, or critical alarm threshold, the system issues an alarm to affected service modules or processes.

(On devices that do not support low memory.) You can use the display memory command to display memory usage information.

(On devices that support low memory.) The system monitors only the amount of free low-memory space. You can use the display memory command to display memory usage information.

(On devices with slots that support low memory.) For slots that support low memory, the system monitors only the amount of free low-memory space. You can use the display memory command to display memory usage information. If the LowMem field is displayed for a slot, the slot supports low memory.

For more information about the alarm thresholds, see Fundamentals Configuration Guide.

Examples

# Set the minor alarm, severe alarm, critical alarm, and normal state thresholds to 64 MB, 48 MB, 32 MB, and 96 MB, respectively.

<Sysname> system-view

[Sysname] memory-threshold minor 64 severe 48 critical 32 normal 96

Related commands

display memory-threshold

memory-threshold dma

Use memory-threshold dma to set DMA memory thresholds.

Use undo memory-threshold dma to restore the default.

Syntax

memory-threshold dma [ slot slot-number [ cpu cpu-number ] ] [ ratio ] critical critical-value normal normal-value

undo memory-threshold dma [ slot slot-number [ cpu cpu-number ] ]

Default

The DMA memory alarm threshold is 2048 KB, and the normal state threshold is 4096 KB.

Views

System view

Predefined user roles

network-admin

network-operator

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets DMA memory thresholds for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

ratio: Specifies DMA memory thresholds in percentage.

critical critical-value: Specifies the DMA memory alarm threshold. If the ratio keyword is specified, the value range for the critical-value argument is 1 to 100 in percentage. If the ratio keyword is not specified, you can enter a question mark (?) in the place of the critical-value argument to view the value range for the threshold..

normal normal-value: Specifies the normal state threshold. If the ratio keyword is specified, the value range for the normal-value argument is 1 to 100 in percentage. If the ratio keyword is not specified, you can enter a question mark (?) in the place of the normal-value argument to view the value range.

Usage guidelines

To ensure correct operation of the services that require DMA memory, the system monitors the amount of free DMA memory space regularly. If the amount of free DMA memory space decreases to or below the alarm threshold, the system generates a notification indicating that the DMA memory space is insufficient. If the amount of free DMA memory space increases above the normal state threshold, the system generates a notification indicating that the DMA memory space is sufficient.

Examples

# Set the DMA memory alarm threshold and the normal state threshold to 32KB and 96 KB, respectively, for slot 1.

<System> system-view

[System] memory-threshold dma slot 1 critical 32 normal 96

memory-threshold usage

Use memory-threshold usage to set the memory usage threshold.

Use undo memory-threshold usage to restore the default.

Syntax

memory-threshold [ slot slot-number [ cpu cpu-number ] ] usage memory-threshold

undo memory-threshold [ slot slot-number [ cpu cpu-number ] ] usage

Default

The memory usage threshold is 85%.

Views

System view

Predefined user roles

network-admin

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the memory usage threshold for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

memory-threshold: Specifies the memory usage threshold in percentage. The value range is 0 to 100.

Usage guidelines

The device samples memory usage at 1-minute intervals. If the sample is greater than the memory usage threshold, the device sends a trap.

Examples

# Set the memory usage threshold to 80%.

<Sysname> system-view

[Sysname] memory-threshold usage 80

Related commands

display memory-threshold

memory-threshold usage resend-interval

Use memory-threshold usage resend-interval to set the memory usage alarm resending interval.

Use undo memory-threshold usage resend-interval to restore the default.

Syntax

memory-threshold [ slot slot-number [ cpu cpu-number ] ] usage resend-interval interval-value

undo memory-threshold [ slot slot-number [ cpu cpu-number ] ] usage resend-interval

Default

The memory usage alarm resending interval is 300 seconds.

Views

System view

Predefined user roles

network-admin

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the interval for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

resend-interval interval-value: Specifies the memory usage alarm resending interval in the range of 1 to 3600, in minutes.

Usage guidelines

The device samples memory usage periodically, and compares the sampled value with the memory usage thresholds. If the sampled value exceeds an alarm threshold, the device enters alarm state and generates an alarm (log and trap) to notify the administrator. If the memory usage remains in the alarm state after the memory usage alarm resending interval is reached, the device outputs the alarm again.

Examples

# Set the memory usage alarm resending interval to 60 minutes for CPU 0 in slot 1.

<Sysname> system-view

[Sysname] memory-threshold slot 1 cpu 0 usage resend-interval 60

monitor cpu-usage enable

Use monitor cpu-usage enable to enable CPU usage monitoring.

Use undo monitor cpu-usage enable to disable CPU usage monitoring.

Syntax

monitor cpu-usage enable [ slot slot-number [ cpu cpu-number ] ]

undo monitor cpu-usage enable [ slot slot-number [ cpu cpu-number ] ]

Default

CPU usage monitoring is enabled.

Views

System view

Predefined user roles

network-admin

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command enables CPU usage monitoring for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

After CPU usage monitoring is enabled, the system samples and saves CPU usage at the interval specified by the monitor cpu-usage interval command. You can use the display cpu-usage history command to view recent CPU usage.

Examples

# Enable CPU usage monitoring.

<Sysname> system-view

[Sysname] monitor cpu-usage enable

Related commands

display cpu-usage configuration

display cpu-usage history

monitor cpu-usage interval

monitor cpu-usage interval

Use monitor cpu-usage interval to set the sampling interval for CPU usage monitoring.

Use undo monitor cpu-usage interval to restore the default.

Syntax

monitor cpu-usage interval interval [ slot slot-number [ cpu cpu-number ] ]

undo monitor cpu-usage interval [ slot slot-number [ cpu cpu-number ] ]

Default

The system samples CPU usage every 1 minute.

Views

System view

Predefined user roles

network-admin

Parameters

interval: Specifies the sampling interval for CPU usage monitoring. Valid values include 5Sec (5 seconds), 1Min (1 minute), and 5Min (5 minutes), case insensitive.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the interval for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

After CPU usage monitoring is enabled, the system samples and saves CPU usage at the specified interval. You can use the display cpu-usage history command to view recent CPU usage.

Examples

# Set the sampling interval for CPU usage monitoring to 5 seconds.

<Sysname> system-view

[Sysname] monitor cpu-usage interval 5Sec

Related commands

display cpu-usage configuration

display cpu-usage history

monitor cpu-usage enable

monitor cpu-usage threshold

Use monitor cpu-usage threshold to set the CPU usage threshold.

Use undo monitor cpu-usage threshold to restore the default.

Syntax

monitor cpu-usage threshold cpu-threshold [ minor-threshold minor-threshold ] [ slot slot-number [ cpu cpu-number ] ]

undo monitor cpu-usage threshold [ minor-threshold ] [ slot slot-number [ cpu cpu-number ] ]

Default

The severe CPU usage alarm threshold is 99%. The minor CPU usage alarm threshold is 79%.

Views

System view

Predefined user roles

network-admin

Parameters

cpu-threshold: Specifies the severe CPU usage alarm threshold in percentage. The value range for this argument is 2 to 100.

minor-threshold minor-threshold: Specifies the minor CPU usage alarm threshold in percentage. The value range for this argument is 1 to the severe CPU usage alarm threshold minus 1. If you do not specify this option, the minor CPU usage alarm threshold is 80 percent of the severe CPU usage alarm threshold.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the CPU usage threshold for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

The device samples CPU usage at 1-minute intervals. If the sample is greater than a CPU usage alarm threshold, the device sends a trap. If the sample is equal to or less than the CPU usage recovery threshold, the device determines that the CPU usage is normal.

Examples

# Set the severe CPU usage threshold to 80%.

<Sysname> system-view

[Sysname] monitor cpu-usage threshold 80

Related commands

display cpu-usage configuration

monitor kernel memory fragment interval

Use monitor kernel memory fragment interval to set the interval for collecting kernel memory fragment information.

Use undo monitor kernel memory fragment interval to restore the default.

Syntax

monitor kernel memory fragment interval interval-value [ slot slot-number [ cpu cpu-number ] ]

undo monitor kernel memory fragment interval [ slot slot-number [ cpu cpu-number ] ]

Default

The interval is five minutes for collecting kernel memory fragment information.

Views

System view

Predefined user roles

network-admin

network-operator

Parameters

interval-value: Specifies the interval in minutes. The value range is 1 to 65535.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the interval for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

The device collects kernel memory fragment statistics at the intervals specified by this command. To view the statistics and identify whether the kernel memory fragment ratio is normal, execute the display kernel memory fragment free command.

Examples

# Set the interval for collecting memory fragment information to 5 minutes.

<System> system-view

[System] monitor kernel memory fragment interval 5

monitor kernel memory fragment ratio

Use monitor kernel memory fragment ratio to set the kernel memory fragment ratio alarm threshold.

Use undo monitor kernel memory fragment ratio to restore the default.

Syntax

monitor kernel memory fragment ratio ratio-value [ slot slot-number [ cpu cpu-number ] ]

undo monitor kernel memory fragment ratio [ slot slot-number [ cpu cpu-number ] ]

Default

The kernel memory fragment ratio alarm threshold is 20%.

Views

System view

Predefined user roles

network-admin

network-operator

Parameters

ratio ratio-value: Specifies the kernel memory fragment ratio alarm threshold in percentage, in the range of 1 to 100.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the kernel memory fragment ratio alarm threshold for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

A running kernel thread's process requires memory allocation from the system. The system allocates and releases this memory as a whole. If the process is still running and some memory blocks have been used but are no longer used, these memory blocks will not be released in advance. These free but currently unusable memory blocks are also referred to as memory fragments.

This command enables the device to monitor the kernel memory fragment ratio. If the kernel memory fragment ratio decreases to or below the alarm threshold, the kernel memory usage is low and an alarm notification is generated. If the kernel memory fragment ratio increases above the alarm threshold, the kernel memory usage returns to the normal state and a recovery notification is generated.

Examples

# Set the kernel memory fragment ratio alarm threshold to 80 for a slot.

<System> system-view

[System] monitor kernel memory fragment ratio 80 slot 1

monitor resend cpu-usage

Use monitor resend cpu-usage to set CPU usage alarm resending intervals.

Use undo monitor resend cpu-usage to restore the default.

Syntax

monitor resend cpu-usage { minor-interval minor-interval | severe-interval severe-interval } * [ slot slot-number [ cpu cpu-number ] ]

undo monitor resend cpu-usage [ minor-interval | severe-interval ] [ slot slot-number [ cpu cpu-number ] ]

Default

The minor CPU usage alarm resending interval is 300 seconds. The severe CPU usage alarm resending interval is 60 seconds.

Views

System view

Predefined user roles

network-admin

Parameters

minor-interval minor-interval: Specifies the minor CPU usage alarm resending interval in seconds, a multiple of 5 in the range of 10 to 3600.

severe-interval severe-interval: Specifies the severe CPU usage alarm resending interval in seconds, a multiple of 5 in the range of 10 to 3600.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the interval for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

The device samples CPU usage at intervals, and compares the samples with CPU usage thresholds to identify the CPU usage status and send alarms or notifications accordingly.

In minor alarm state, the device sends minor alarms periodically until the CPU usage increases above the severe threshold or the minor alarm is removed. In severe alarm state, the device sends severe alarms periodically until the severe alarm is removed. This command sets the alarm resending intervals.

If you do not specify a keyword for the undo monitor resend cpu-usage command, the command restores the default minor and severe CPU usage alarm resending intervals.

Examples

# Set the minor CPU usage alarm resending interval to 60 seconds for a slot.

<Sysname> system-view

[Sysname] monitor resend cpu-usage minor-interval 60 slot 1 cpu 0

monitor resend cpu-usage core-interval

Use monitor resend cpu-usage core-interval to set CPU core usage alarm resending intervals.

Use undo monitor resend cpu-usage core-interval to restore the default.

Syntax

monitor resend cpu-usage core-interval { minor-interval minor-interval | severe-interval severe-interval } * [ slot slot-number [ cpu cpu-number ] ]

undo monitor resend cpu-usage core-interval [ minor-interval | severe-interval ] [ slot slot-number [ cpu cpu-number ] ]

Default

The resending intervals for minor CPU core usage alarms and severe CPU core usage alarms are all 300 seconds.

Views

System view

Predefined user roles

network-admin

Parameters

minor-interval minor-interval: Specifies the resending interval for minor CPU core usage alarms in seconds, a multiple of 5 in the range of 10 to 3600.

severe-interval severe-interval: Specifies the resending interval for severe CPU core usage alarms in seconds, a multiple of 5 in the range of 10 to 3600.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the interval for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

The device samples CPU core usage at intervals, and compares the samples with CPU core usage thresholds to identify the CPU core usage status and send alarms or notifications accordingly.

In minor alarm state, the device sends minor alarms periodically until the CPU core usage increases above the severe threshold or the minor alarm is removed. In severe alarm state, the device sends severe alarms periodically until the severe alarm is removed. This command sets the alarm resending intervals.

Examples

# Set the resending interval for minor CPU core usage alarms to 100 seconds and the resending interval for severe CPU core usage alarms 60 seconds.

<Sysname> system-view

[Sysname] monitor resend cpu-usage core-interval minor-interval 100 severe-interval 60

monitor resend memory-threshold

Use monitor resend memory-threshold to set free memory depletion alarm resending intervals.

Use undo monitor resend memory-threshold to restore the default.

Syntax

monitor resend memory-threshold { critical-interval critical-interval | minor-interval minor-interval | severe-interval severe-interval } * [ slot slot-number [ cpu cpu-number ] ]

undo monitor resend memory-threshold [ critical-interval | early-warning-interval | minor-interval | severe-interval ] * [ slot slot-number [ cpu cpu-number ] ]

Default

·     Early warning resending interval: 1 hour.

·     Minor alarm resending interval: 12 hours.

·     Severe alarm resending interval: 3 hours.

·     Critical alarm resending interval: 1 hour.

Views

System view

Predefined user roles

network-admin

Parameters

critical-interval critical-interval: Specifies the critical alarm resending interval in hours, in the range of 1 to 48.

early-warning-interval early-warning-interval: Specifies the early warning resending interval in hours, in the range of 1 to 48.

minor-interval minor-interval: Specifies the minor alarm resending interval in hours, in the range of 1 to 48.

severe-interval severe-interval: Specifies the severe alarm resending interval in hours, in the range of 1 to 48.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets alarm resending intervals for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

The device samples the amount of free memory space periodically and compares the sampled value with free-memory thresholds. If the sampled value decreases to or below a threshold, the device enters a memory depletion alarm state and sends an alarm.

In critical alarm state, the device sends critical alarm notifications periodically until the critical alarm is removed.

In a lower alarm state, the device sends notifications for the alarm state periodically until it enters a higher alarm state or the current alarm is removed.

You can use this command to change the alarm resending intervals.

Examples

# Set the minor memory depletion alarm resending interval to 12 hours for CPU 0 in slot 1.

<Sysname> system-view

[Sysname] monitor resend memory-threshold minor-interval 12 slot 1 cpu 0

monitor resend memory-threshold dma

Use monitor resend memory-threshold dma to set the DMA memory alarm resending interval.

Use undo monitor resend memory-threshold dma to restore the default.

Syntax

monitor resend memory-threshold dma critical-interval critical-interval [ slot slot-number [ cpu cpu-number ] ]

undo monitor resend memory-threshold dma critical-interval [ slot slot-number [ cpu cpu-number ] ]

Default

The DMA memory alarm resending interval is 300 seconds.

Views

System view

Predefined user roles

network-admin

Parameters

critical-interval critical-interval: Specifies the resending interval for the DMA memory alarms in seconds, a multiple of 5 in the range of 10 to 3600.

slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command sets the interval for the active MPU.

cpu cpu-number: Specifies a CPU by its number.

Usage guidelines

The device samples DMA memory usage at intervals, and compares the samples with the DMA memory alarm threshold to identify the DMA memory usage status and send alarms or notifications accordingly.

Examples

# Set the resending interval for the DMA memory alarms to 100 seconds.

<Sysname> system-view

[Sysname] monitor resend memory-threshold dma critical-interval 100<Sysname> system-view

password-recovery enable

Use password-recovery enable to enable password recovery capability.

Use undo password-recovery enable to disable password recovery capability.

Syntax

password-recovery enable

undo password-recovery enable

Default

Password recovery capability is enabled.

Views

System view

Predefined user roles

network-admin

Usage guidelines

Password recovery capability controls console user access to the device configuration and SDRAM from BootWare menus.

If password recovery capability is enabled, a console user can access the device configuration without authentication to configure new passwords.

If password recovery capability is disabled, console users must restore the factory-default configuration before they can configure new passwords. Restoring the factory-default configuration deletes the next-startup configuration files.

To enhance system security, disable password recovery capability.

To access the device configuration without authentication, you must connect to the active MPU and access the BootWare menu while the MPU is starting up.

Availability of BootWare menu options depends on the password recovery capability setting. For more information, see the release notes.

Examples

# Disable password recovery capability.

<Sysname> system-view

[Sysname] undo password-recovery enable

reboot

Use reboot to reboot the device.

Syntax

reboot [ slot slot-number [ cpu cpu-number ] ] [ force ]

Views

User view

Predefined user roles

network-admin

Parameters

slot slot-number: Specifies a card by its slot number. If you do not specify a card, the command reboots the entire device.

cpu cpu-number: Specifies a CPU by its CPU number. If you do not specify a CPU, the command reboots the slot.

force: Reboots the device immediately without performing software or hard disk check. If this keyword is not specified, the system first identifies whether the reboot might result in data loss or a system failure. For example, the system identifies whether the main system software image file exists and whether a write operation is in progress on a storage medium. If the reboot might cause problems, the system does not reboot the device.

Usage guidelines

CAUTION

CAUTION:

·     A reboot might interrupt network services.

·     Use the force keyword only when the device fails or a reboot command without the force keyword cannot perform a reboot correctly. A reboot command with the force keyword might result in file system corruption because it does not perform data protection.

If the main startup software images are corrupt or missing, you must re-specify a set of main startup software images before executing the reboot command.

For data security, the device does not reboot if you reboot the device while the device is performing file operations.

If the device does not have a standby MPU, rebooting the active MPU reboots the entire device. If the device has a standby MPU and the standby MPU is operating correctly, rebooting the active MPU triggers a switchover.

To ensure correct operation of the system and cards, do not trigger a switchover by rebooting the active MPU if the standby MPU is not in Stable state. To view the status of the standby MPU, execute the display system stable state command.

Examples

# Reboot the device. Save the running configuration at prompt.

<Sysname> reboot

Start to check configuration with next startup configuration file, please wait.........DONE!

Current configuration will be lost after the reboot, save current configuration? [Y/N]:y

Please input the file name(*.cfg)[flash:/startup.cfg]

(To leave the existing filename unchanged, press the enter key):

flash:/startup.cfg exists, overwrite? [Y/N]:y

Validating file. Please wait...

Configuration is saved to mainboard device successfully.

This command will reboot the device. Continue? [Y/N]:y

Now rebooting, please wait...

# Reboot the device immediately without performing software check.

<Sysname> reboot force

A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y

Now rebooting, please wait...

Related commands

display system stable state

reset scheduler logfile

Use reset scheduler logfile to clear job execution log information.

Syntax

reset scheduler logfile

Views

User view

Predefined user roles

network-admin

Examples

# Clear job execution log information.

<Sysname> reset scheduler logfile

Related commands

display scheduler logfile

reset version-update-record

Use reset version-update-record to clear startup software image upgrade records.

Syntax

reset version-update-record

Views

System view

Predefined user roles

network-admin

Examples

# Clear the startup software image upgrade records.

<Sysname> system-view

[Sysname] reset version-update-record

This command will delete all records of version update. Continue? [Y/N]:y

Related commands

display version-update-record

 

restore factory-default

Use restore factory-default to restore the factory-default configuration for the device.

Syntax

restore factory-default

Views

User view

Predefined user roles

network-admin

Usage guidelines

CAUTION

CAUTION:

This command restores the device to the factory default settings. Before using this command, make sure you fully understand its impact on your live network.

 

Use this command only when you cannot troubleshoot the device by using other methods, or you want to use the device in a different scenario.

The command takes effect after the device reboots.

Examples

# Restore the factory-default configuration for the device.

<Sysname> restore factory-default

This command will restore the system to the factory default configuration and clear the operation data. Continue [Y/N]:y

Restoring the factory default configuration. This process might take a few minutes. Please wait..........................................................................................................Done.

Please reboot the system to place the factory default configuration into effect.

Related commands

reboot

scheduler job

Use scheduler job to create a job and enter its view, or enter the view of an existing job.

Use undo scheduler job to delete a job.

Syntax

scheduler job job-name

undo scheduler job job-name

Default

No job exists.

Views

System view

Predefined user roles

network-admin

Parameters

job-name: Specifies the job name, a case-sensitive string of 1 to 47 characters.

Usage guidelines

A job can be referenced by multiple schedules. In job view, you can assign commands to the job.

Examples

# Create a job named backupconfig and enter job view.

<Sysname> system-view

[Sysname] scheduler job backupconfig

[Sysname-job-backupconfig]

Related commands

command

scheduler schedule

scheduler logfile size

Use scheduler logfile size to set the size of the job execution log file.

Syntax

scheduler logfile size value

Default

The size of the job execution log file is 16 KB.

Views

System view

Predefined user roles

network-admin

Parameters

value: Specifies the size of the job execution log file, in KB. The value range is 16 to 1024.

Usage guidelines

The job execution log file saves the execution information of jobs. If the file is full, old records are deleted to make room for new records. If the size of the log information to be written to the file is greater than the file size, the excessive information is not written to the file.

Examples

# Set the size of the job execution log file to 32 KB.

<Sysname> system-view

[Sysname] scheduler logfile size 32

Related commands

display scheduler logfile

scheduler reboot at

Use scheduler reboot at to specify the reboot date and time.

Use undo scheduler reboot to delete the reboot schedule configuration.

Syntax

scheduler reboot at time [ date ]

undo scheduler reboot

Default

No reboot date or time is specified.

Views

User view

Predefined user roles

network-admin

Parameters

time: Specifies the reboot time in the hh:mm format. The value range for hh is 0 to 23. The value range for mm is 0 to 59.

date: Specifies the reboot date in the MM/DD/YYYY or YYYY/MM/DD format. The value range for YYYY is 2000 to 2035. The value range for MM is 1 to 12. The value range for DD varies by month.

Usage guidelines

CAUTION

CAUTION:

This command enables the device to reboot at a scheduled time, which causes service interruption. Before using this command, make sure you fully understand its impact on your live network.

When the date argument is not specified, the system uses the following rules to determine the reboot time:

·     If the reboot time is later than the current time, a reboot occurs at the reboot time of the current day.

·     If the reboot time is earlier than the current time, a reboot occurs at the reboot time the next day.

The device supports only one device reboot schedule. If you execute both the scheduler reboot delay and scheduler reboot at commands or execute one of the commands multiple times, the most recent configuration takes effect.

For data security, the system does not reboot at the reboot time if a file operation is being performed.

Examples

# Configure the device to reboot at 12:00 p.m. This example assumes that the current time is 11:43 a.m. on June 6, 2011.

<Sysname> scheduler reboot at 12:00

Reboot system at 12:00:00 06/06/2011 (in 0 hours and 16 minutes). Confirm? [Y/N]:

Related commands

scheduler reboot delay

scheduler reboot delay

Use scheduler reboot delay to specify the reboot delay time.

Use undo scheduler reboot to delete the reboot schedule configuration.

Syntax

scheduler reboot delay time

undo scheduler reboot

Default

No reboot delay time is specified.

Views

User view

Predefined user roles

network-admin

Parameters

time: Specifies the reboot delay time in the hh:mm or mm format. This argument can contain up to six characters. When in the hh:mm format, mm must be in the range of 0 to 59.

Usage guidelines

CAUTION

CAUTION:

This command enables the device to reboot at a scheduled time, which causes service interruption. Before using this command, make sure you fully understand its impact on your live network.

The device supports only one device reboot schedule. If you execute both the scheduler reboot delay and schedule reboot at commands or execute one of the commands multiple times, the most recent configuration takes effect.

For data security, the system does not reboot at the reboot time if a file operation is being performed.

Examples

# Configure the device to reboot after 88 minutes. This example assumes that the current time is 11:48 a.m. on June 6, 2011.

<Sysname> scheduler reboot delay 88

Reboot system at 13:16 06/06/2011(in 1 hours and 28 minutes). Confirm? [Y/N]:

scheduler schedule

Use scheduler schedule to create a schedule and enter its view, or enter the view of an existing schedule.

Use undo scheduler schedule to delete a schedule.

Syntax

scheduler schedule schedule-name

undo scheduler schedule schedule-name

Default

No schedule exists.

Views

System view

Predefined user roles

network-admin

Parameters

schedule-name: Specifies the schedule name, a case-sensitive string of 1 to 47 characters.

Usage guidelines

You can configure a schedule to have the device automatically run a command or a set of commands without administrative interference.

To configure a schedule:

1.     Use the scheduler job command to create a job and enter job view.

2.     Use the command command to assign commands to the job.

3.     Use the scheduler schedule command to create a schedule and enter schedule view.

4.     Use the job command to assign the job to the schedule. You can assign multiple jobs to a schedule. The jobs must already exist.

5.     Use the user-role command to assign user roles to the schedule. You can assign up to 64 user roles to a schedule.

6.     Use the time at, time once, or time repeating command to specify an execution time for the schedule. You can specify only one execution time for a schedule.

Examples

# Create a schedule named saveconfig.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

Related commands

job

time at

time once

shutdown-interval

Use shutdown-interval to set the port status detection timer.

Use undo shutdown-interval to restore the default.

Syntax

shutdown-interval interval

undo shutdown-interval

Default

The port status detection timer setting is 30 seconds.

Views

System view

Predefined user roles

network-admin

Parameters

interval: Specifies the port status detection timer value in seconds. The value range is 0 to 300. Value 0 indicates that port status detection is not automatically performed, and you need to execute the undo shutdown command to restore the port status.

Usage guidelines

The device starts a port status detection timer when a port is shut down by a protocol. If the port has been in down state before the timer expires, the device will set the port status to the port's physical status.

If you change the timer setting during port detection, the device compares the new setting (T1) with the time that elapsed since the port was shut down (T).

·     If T < T1, the port will be brought up after T1 – T seconds.

·     If T ≥ T1, the port is brought up immediately.

For example, the timer setting is 30 seconds. If you change it to 10 seconds 2 seconds after the port is shut down, the port will come up 8 seconds later. If you change the timer setting to 2 seconds 10 seconds after the port is shut down, the port comes up immediately.

Examples

# Set the port status detection timer to 100 seconds.

<Sysname> system-view

[Sysname] shutdown-interval 100

sysname

Use sysname to set the device name.

Use undo sysname to restore the default.

Syntax

sysname sysname

undo sysname

Default

The device name is H3C.

Views

System view

Predefined user roles

network-admin

Parameters

sysname: Specifies a name for the device, a string of 1 to 64 characters.

Usage guidelines

A device name identifies a device in a network and is used in CLI view prompts. For example, if the device name is Sysname, the user view prompt is <Sysname>.

Examples

# Set the name of the device to R2000.

<Sysname> system-view

[Sysname] sysname R2000

[R2000]

time at

Use time at to specify an execution date and time for a non-periodic schedule.

Use undo time to delete the execution date and time configuration for a non-periodic schedule.

Syntax

time at time date

undo time

Default

No execution time or date is specified for a non-periodic schedule.

Views

Schedule view

Predefined user roles

network-admin

Parameters

time: Specifies the schedule execution time in the hh:mm format. The value range for hh is 0 to 23. The value range for mm is 0 to 59.

date: Specifies the schedule execution date in the MM/DD/YYYY or YYYY/MM/DD format. The value range for YYYY is 2000 to 2035. The value range for MM is 1 to 12. The value range for DD varies by month.

Usage guidelines

The specified time (date plus time) must be later than the current system time.

The time at command, the time once command, and the time repeating command overwrite each other. The most recently executed command takes effect.

Examples

# Configure the device to execute the saveconfig schedule at 01:01 a.m. on May 11, 2011.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time at 1:1 2011/05/11

Related commands

scheduler schedule

time once

Use time once to specify one or more execution days and the execution time for a non-periodic schedule.

Use undo time to delete the execution day and time configuration for a non-periodic schedule.

Syntax

time once at time [ month-date month-day | week-day week-day&<1-7> ]

time once delay time

undo time

Default

No execution time or day is specified for a non-periodic schedule.

Views

Schedule view

Predefined user roles

network-admin

Parameters

at time: Specifies the execution time in the hh:mm format. The value range for hh is 0 to 23. The value range for mm is 0 to 59.

month-date month-day: Specifies a day in the current month, in the range of 1 to 31. If you specify a day that does not exist in the current month, the configuration takes effect on that day in the next month.

week-day week-day&<1-7>: Specifies a space-separated list of up to seven week days for the schedule. Valid week day values include Mon, Tue, Wed, Thu, Fri, Sat, and Sun.

delay time: Specifies the delay time for executing the schedule, in the hh:mm or mm format. This argument can have up to six characters. When in the hh:mm format, mm must be in the range of 0 to 59.

Usage guidelines

If the specified time has already occurred, the schedule will be executed at the specified time the following day.

If the day in the month has already occurred, the schedule will be executed at the specified day in the following month.

If the specified day in a week has already occurred, the schedule will be executed at the specified day in the following week.

The time at command, the time once command, and the time repeating command overwrite each other. The most recently executed command takes effect.

Examples

# Configure the device to execute the saveconfig schedule once at 15:00.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once at 15:00

Schedule starts at 15:00 5/11/2011.

# Configure the device to execute the saveconfig schedule once at 15:00 on the coming 15th day in a month.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once at 15:00 month-date 15

# Configure the device to execute the saveconfig schedule at 12:00 p.m. on the coming Monday and Friday.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once at 12:00 week-day mon fri

# Configure the device to execute the saveconfig schedule after 10 minutes.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once delay 10

Related commands

scheduler schedule

time repeating

Use time repeating to specify an execution time table for a periodic schedule.

Use undo time to delete the execution time table configuration for a periodic schedule.

Syntax

time repeating [ at time [ date ] ] interval interval

time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]

undo time

Default

No execution time table is specified for a periodic schedule.

Views

Schedule view

Predefined user roles

network-admin

Parameters

at time: Specifies the execution time in the hh:mm format. The value range for hh is 0 to 23. The value range for mm is 0 to 59. If you do not specify this option, the current system time is used as the execution time.

date: Specifies the start date for the periodic schedule, in the MM/DD/YYYY or YYYY/MM/DD format. The value range for YYYY is 2000 to 2035. The value range for MM is 1 to 12. The value range for DD varies by month. If you do not specify this argument, the execution start date is the first day when the specified time arrives.

interval interval: Specifies the execution time interval in the hh:mm or mm format. This argument can have up to six characters. When in the hh:mm format, mm must be in the range of 0 to 59. When in the mm format, this argument must be equal to or greater than 1 minute.

month-date [ month-day | last ]: Specifies a day in a month, in the range 1 to 31. The last keyword indicates the last day of a month. If you specify a day that does not exist in a month, the configuration takes effect on that day in the next month.

week-day week-day&<1-7>: Specifies a space-separated list of up to seven week days for the schedule. Valid week day values include Mon, Tue, Wed, Thu, Fri, Sat, and Sun.

Usage guidelines

The time repeating [ at time [ date ] ] interval interval command configures the device to execute a schedule at intervals from the specified time on.

The time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ] command configures the device to execute a schedule at the specified time on every specified day in a month or week.

The time at command, the time once command, and the time repeating command overwrite each other, whichever is executed most recently takes effect.

Examples

# Configure the device to execute the saveconfig schedule once an hour from 8:00 a.m. on.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 interval 60

# Configure the device to execute the saveconfig schedule at 12:00 p.m. every day.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 12:00

# Configure the device to execute the saveconfig schedule at 8:00 a.m. on the 5th of every month.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 month-date 5

# Configure the device to execute the saveconfig schedule at 8:00 a.m. on the last day of every month.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 month-date last

# Configure the device to execute the saveconfig schedule at 8:00 a.m. every Friday and Saturday.

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 week-day fri sat

Related commands

scheduler schedule

user-role

Use user-role to assign user roles to a schedule.

Use undo user-role to remove user roles from a schedule.

Syntax

user-role role-name

undo user-role role-name

Default

A schedule has the user roles of the schedule creator.

Views

Schedule view

Predefined user roles

network-admin

Parameters

role-name: Specifies a user role name, a case-sensitive string of 1 to 63 characters. The user role can be user-defined or predefined. Predefined user roles include network-admin, network-operator, and level-0 to level-15.

Usage guidelines

A schedule must have one or more user roles. A command in a schedule can be executed if it is permitted by one or more user roles of the schedule. For more information about user roles, see the RBAC configuration in Fundamentals Configuration Guide.

A schedule can have a maximum of 64 user roles. After the limit is reached, you cannot assign additional user roles to the schedule.

The security log manager user role is mutually exclusive with other user roles. That is, if the security log manager user role has been assigned, the system will automatically remove the existing other user roles. If the other user roles have been assigned, the system will automatically remove the existing security log manager user role.

Examples

# Assign the rolename user role to the test schedule.

<sysname> system-view

[Sysname] scheduler schedule test

[Sysname-schedule-test] user-role rolename

# Assign the security-audit user role to the test schedule.

<sysname> system-view

[Sysname] scheduler schedule test

[Sysname-schedule-test]user-role security-audit

This operation will delete all other user roles for the schedule. Are you sure? [Y/N]:y

# Change the user role assigned to the test schedule from security-audit to network-admin.

<sysname> system-view

[Sysname] scheduler schedule test

[Sysname-schedule-test]user-role network-admin

This operation will delete security auditor user role for the schedule. Are you sure? [Y/N]:y

Related commands

command

scheduler schedule

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services