H3C SecCenter SMP

Release time:2022-07-07
HomeSupportSecurityH3C SecCenter SMPSoftware DownloadSecCenter SMP
Download

 

SecCenterSMP-E1704P02 Release Notes


Contents

Introduction· 1

Version information· 1

Version number 1

Version history· 1

Hardware and software compatibility matrix· 1

Upgrade restrictions and guidelines· 2

Hardware feature updates· 2

Software feature updates· 2

MIB updates· 2

Operation changes· 2

Restrictions and cautions· 2

Licensing· 3

About licensing· 3

Registering and installing licenses· 3

Open problems and workarounds· 3

List of resolved problems· 4

Resolved problems in SecCenterSMP-E1704P02· 4

Resolved problems in SecCenterSMP-E1704P01· 5

Resolved problems in SecCenterSMP-E1704· 5

Troubleshooting resources· 5

Related documentation· 5

Documentation set 5

Obtaining documentation· 5

Technical support 6

Appendix A Feature list 7

Hardware features· 7

Software features· 7

Appendix B Upgrading software· 9

 

List of tables

Table 1 Compatibility matrix. 1

Table 2 Software features of SMP. 7

 

 


Introduction

This document describes the features, restrictions and guidelines, open problems, and workarounds for version SecCenterSMP-E1704P01. Before you use this version on a live network, back up the configuration and test the version to avoid software upgrade affecting your live network.

Use this document in conjunction with the documents listed in Related documentation.

Version information

Version number

SecCenterSMP-E1704P02

Version history

Version number

Last version

Release date

Release type

Remarks

SecCenterSMP-E1704P02

SecCenterSMP-E1704P01

2022/06/28

ESS

Fixed bugs.

SecCenterSMP-E1704P01

SecCenterSMP-E1704

2022/04/22

ESS

Fixed bugs.

SecCenterSMP-E1704

SecCenterSMP-E1110P06

2021/06/29

ESS

Fixed bugs.

 

Hardware and software compatibility matrix

CAUTION:

To avoid an upgrade failure, use the following to verify the hardware and software compatibility before performing an upgrade.

 

Table 1 Compatibility matrix

Item

H3C SecCenterSMP series

Model

SecCenterSMP

Installation file

SecCenterSMP_E1704P02_EN.iso (package for virtualized deployment)

Server version

H3Linux 1.1.1

Installation host OS

N/A

Browsers

Google Chrome 57 or higher

Remarks

N/A

 

Upgrade restrictions and guidelines

Initial deployment version for the SMP English edition. Upgrade is not supported.

Hardware feature updates

SMP is a software product and contains no hardware features.

Software feature updates

N/A.

MIB updates

N/A

Operation changes

N/A

Restrictions and cautions

For browsers

To get better display, use browsers Google Chrome 57 or higher.

For the operating system

Set the time zone in the operating system to Shanghai East 8 district.

For device version compatibility

·            Compatible device versions are D032 and D045.

·            Configure the device to use the local time in the log timestamp. If you configure the device to use the standard GMT, the log timestamp displayed on the SMP will be different from that on the device.

·            The system supports receiving a maximum of 10000 log messages per second from devices. Exceeding logs will be dropped.

Licensing

About licensing

H3C offers licensing options for you to deploy features and expand resource capacity on an as needed basis. To use license-based features, purchase licenses from H3C and install the licenses.

Registering and installing licenses

To register and transfer licenses, access H3C license services at http://www.h3c.com/en/License.

For information about registering licenses, installing activation files, and transferring licenses, see 《H3C SecCenter SMP Licensing Guide-5W100》。

Open problems and workarounds

202103301207

·            Symptom: The area collector drop-down list contains no options sometimes, resulting in area creation failure.

·            Condition:None.

·            Workaround: Restart the cloudops service in the CLI.

202010261209

·            Symptom: You cannot delete, edit, or redeploy the IPS whitelist entries that failed to be deployed due to exceeding the maximum number of entries allowed.

·            Condition:None.

·            Workaround: None.

202104230453

·            Symptom: When you add or edit a security zone, if you change the device after interfaces are selected, the interface list for the security zone retains the interfaces previously selected.

·            Condition:None.

·            Workaround: None.

202009160688

·            Symptom: Create vulnerability and virus subrules for a correlation rule. The subrules require full match. Construct logs that match the subrules. The generated security events contain only vulnerability logs.

·            Condition:None.

·            Workaround: None.

202004070875

·            Symptom: Bulk synchronize assets. During the synchronization, the asset CPU usage and memory usage are not displayed. After you restart the cloudops service, the SMP cannot obtain the CPU usage and memory usage of some assets.

·            Condition:None.

·            Workaround: None.

202003060735

·            Symptom: When you import a license that contains hierarchical management authorization, the cloudops service will restart. In this case, you are unable to log in to the system, and the webpage prompts “Failed to obtain license information” or “Please import the correct license.” If you import other licenses, the licenses cannot be activated.

·            Condition:None.

·            Workaround: Include one hierarchical management license in the first license file imported to system. Do not include a hierarchical management license in subsequent imports of licenses.

202204221243

·            Symptom: System leave some chinese chracters to be translated.

·            Condition:None.

·            Workaround: None.

List of resolved problems

Resolved problems in SecCenterSMP-E1704P02

202206140791

·            Symptom: Some Belt and Road Initiative countries are not available in the country list for SMP license registration.

·            Condition: This symptom occurs when you request and register the SMP license.

202205251156

·            Symptom: The H3Linux interface displays information in Chinese when you install the English version SMP system by using an ISO file.

·            Condition: This symptom occurs when you install English version SMP system by using an ISO file.

Resolved problems in SecCenterSMP-E1704P01

202106290415

·            Symptom: For initial import of licenses to the platform, if the licenses imported include the hierarchical management license, the number of the hierarchical management license generated in the platform is greater than 1, and the license cannot be activated. For additional import of licenses to the platform, if the licenses imported include the hierarchical management license, the platform prompts that you should import the correct license.

·            Condition: None.

Resolved problems in SecCenterSMP-E1704

202106281458

·            Symptom: The cumulative number of licenses in the SMP platform is incorrect. It records only one Additional 1 Node License.

·            Condition: None.

Troubleshooting resources

To obtain troubleshooting resources for the product:

1.      Access Technical Documents at http://www.h3c.com/en/Technical_Documents.

2.      Select the device category and model.

3.      Select the Maintain or Maintenance menu.

Related documentation

Documentation set

·            H3C SecCenter SMP Web Configuration Guides(E1704)-5W100

·            H3C SecCenter SMP Configuration Examples (E1704)-5W100

·            H3C SecCenter SMP FAQ(E1704)-5W100

·            H3C SecCenter SMP Troubleshooting Guide(E1704)-5W100

Obtaining documentation

To obtain related documents from the H3C website at

https://www.h3c.com/en/Support/Resource_Center/Technical_Documents/

Technical support

To obtain technical assistance, contact H3C by using one of the following methods:

·            Email:

h3cts@h3c.com (countries and regions except Hong Kong, China)

service_hk@h3c.com (Hong Kong, China)

·            Technical support hotline number. To obtain your local technical support hotline number, go to the H3C Service Hotlines website: https://www.h3c.com/en/Support/Online_Help/Service_Hotlines/

To access documentation, go to the H3C website at http://www.h3c.com/en/.


Appendix A Feature list

Hardware features

SMP is a software product and contains no hardware features.

Software features

Table 2 Software features of SMP

Categories

Features

Dashboard

 

 

 

CPU Usage

Memory Usage

Session Trend

IPS Attack Destination IPs

IPS Attack Source and Destination IPs

IPS Blocked Events

Attack Trend Chart

Device Log Receiving Trend Chart

Alarm Events

 

 

Alarm Events

Alarm Rules

Alarm Notification Policies

Alarm Notification Records

Log Audit

 

 

Vulnerability Attack Log

Virus Attack Log

NAT Session Log

NAT444 Port Block Log

NAT444 Session Log

Application Audit Logs

Security Analysis

 

 

Security Event Analysis

Reports

 

 

Report Files

Report Tasks

Report Templates

O&M

 

 

Areas

Device Groups

Monitored Assets

Security Services

Signature Libraries

System Settings

 

 

Global Settings

System Monitoring

Roles & Privileges

Logging

Customization

System Info

Licenses

Hierarchy


Appendix B Upgrading software

The SMP English edition supports only virtualized deployment by using an ISO package. Upgrade is not supported.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网