• 产品与解决方案
  • 行业解决方案
  • 服务
  • 支持
  • 合作伙伴
  • 新华三人才研学中心
  • 关于我们
首页 支持 文档与软件 软件下载 服务器

NIC-BCM957508-N2100G-3S-2P(2025/12/31)

类型:

Firmware-NIC

版本:

234.1.124.0

操作系统:

N/A-N/A

    说明

  • 说明
  • 安装步骤
  • 发布说明
  • 解决问题
  • 新增功能
  • 历史版本
  • 说明

    The software is the firmware upgrade program for Broadcom BCMCD network card version 234.1.124.0.

  • 安装步骤

    Restrictions and guidelines

    1.Before updating the software version, it is strongly recommended that you understand the software feature changes between versions, evaluate the potential impact of the changes on your business, and consult relevant supporting materials.

    2.Firmware version 225.3.41.0 and subsequent versions delete the hotkey to enter the interface of the network card OptionRom configuration item under Legacy BIOS, and no longer support the configuration of network card under Legacy BIOS.

    Installation steps

    Linux OS

    1.Log in to the system with an administrator account.

    2.Upload the firmware package (nvmUpgrade_xxx_H3C_Vxx_xxx) to a system-accessible path.

    3.Execute the following command:

    unzip nvmUpgrade_xxx_H3C_Vxx_xxx ##Extract the file

    4.cd nvmUpgrade_xxx_H3C_Vxx_xxx/ ##Enter the extracted file

    5.Execute the following commands:

    chmod 777 -R * ##Grant permission

    ./install.sh --force ##Execute the firmware upgrade script

    6.After the firmware upgrade is successful, power off the server and restart it to make the new firmware effective.

    7.Entering the system, execute the ethtool -i command to check that the NIC firmware version is the target version.

    Windows OS

    1.Log in to the server operating system with an administrator account.

    2.Upload the firmware package (AutoUpgrade_windows_xxx_H3C_Vxx_xxx) to a system-accessible path.

    3.Extract the firmware package.

    4.Double-click on auto_upgrade.bat and follow the prompts to install.

    5.After the firmware upgrade is successful, power off the server and restart it to make the new firmware effective.

    VMware OS

    1.Log in to the server operating system with an administrator account.

    2.Upload the firmware package (nvmUpgrade_ESXi_xxx_H3C_Vxx_xxx) to a system-accessible path, such as /vmfs/volumes/datastore1/.

    3.Execute the following command:

    unzip nvmUpgrade_ESXi_xxx_H3C_Vxx_xxx ##Extract the file

    cd nvmUpgrade_ESXi_xxx_H3C_Vxx_xxx/ ##Enter the extracted file

    4.Execute the following commands:

    chmod 777 -R * ##Grant permission

    ./install.sh --force   ##Execute the firmware upgrade script

    5.After the firmware upgrade is successful, power off the server and restart it to make the new firmware effective.

    6.Entering the system, execute the esxcli network nic get -n vmnicX command to check that the NIC firmware version is the target version.

  • 发布说明

    Supported products

    H3C UniServer B5700 G3

    H3C UniServer B5700 G5

    H3C UniServer B5800 G3

    H3C UniServer B7800 G3

    H3C UniServer E3200 G3

    H3C UniServer R2700 G3

    H3C UniServer R2900 G3

    H3C UniServer R4300 G3

    H3C UniServer R4300 G5

    H3C UniServer R4330 G5

    H3C UniServer R4330 G5 H3

    H3C UniServer R4500 G3

    H3C UniServer R4700 G3

    H3C UniServer R4700 G5

    H3C UniServer R4700 G6

    H3C UniServer R4900 G3

    H3C UniServer R4900 G5

    H3C UniServer R4900 G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4930 G5

    H3C UniServer R4930 G5 H3

    H3C UniServer R4950 G5

    H3C UniServer R4950 G5 Milan

    H3C UniServer R4950 G5 Rome

    H3C UniServer R4950 G6

    H3C UniServer R5300 G3

    H3C UniServer R5300 G5

    H3C UniServer R5500 G5 AMD

    H3C UniServer R5500 G5 Intel

    H3C UniServer R6700 G3

    H3C UniServer R6900 G3

    H3C UniServer R8900 G3

    H3C UniServer R5350 G6

    H3C UniServer R6900 G5

    H3C UniServer R5500 G6 AMD

    H3C UniServer R5500 G6 Intel

    H3C UniServer R5300 G6

    H3C UniServer R5500LC G5 Intel

    H3C UniServer R5500 G5 HYGON

    H3C UniServer B5700 G6

    H3C UniServer R4900LE G6 Ultra

    H3C UniServer R4700LE G6

    H3C UniServer R4900LC G5

    H3C UniServer R4700LC G5

    H3C UniServer R4930LC G5 H3

    H3C UniServer R4300 G6

    H3C UniServer R4500 G6

    H3C UniServer R6700 G6

    H3C UniServer R6900 G6

    H3C UniServer R5330 G7

    H3C UniServer R5500 G7 Hygon

    H3C UniServer R4930 G7

    H3C UniServer E3300 G6

    H3C UniServer R3950 G6

    H3C UniServer R4330 G7

    H3C UniServer R4950 G7

    H3C UniServer R3950 G7

    H3C UniServer R3350 G7

    H3C UniServer R4900 G7

    H3C UniServer R4700 G7

    H3C UniServer R3900 G7

    H3C UniServer R4300 G7

    Restrictions and guidelines

    1.Before updating the software version, it is strongly recommended that you understand the software feature changes between versions, evaluate the potential impact of the changes on your business, and consult relevant supporting materials.

    2.Firmware version 225.3.41.0 and subsequent versions delete the hotkey to enter the interface of the network card OptionRom configuration item under Legacy BIOS, and no longer support the configuration of network card under Legacy BIOS.

  • 解决问题

    1.The issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552).

    2.Wh+: Communication issue caused by updating Broadcom 57414 network card firmware when enabling software untag VLAN (DCSG-41528).

    3.When the versions of the active image and pending image are the same, the PLDM firmware update does not display the image to be updated (DCSG-40211).

    4.The latest PLDM time cannot be sent to BMC (DCSG-37593).

    5.Whp: Mgmt: Discard LLDP packet (DCSG-34687) if RMII is not enabled.

    6.Correct the GPIO reuse value of OCP chain pins (DCSG-31638).

    7.Niccli windows: Counter clear operation (--- clear) failed (DCSG-30477).

    8.There is a timing vulnerability (DCSG-29165) in the current implementation between clearing the temperature valid flag and reading/verifying the temperature.

    9.Whp: Mgmt: Always forward LLDP packets to BMC (DCSG-29361).

    10.HWRM error (DCSG-22697) occurred while verifying link status on WHITNEY+device.

    [ +40.128023] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x142 error 0x3

    [ +0.000172] bnxt_en 0000:a1:00.1 eth9: hwrm req_type 0xfff1 seq id 0x143 error 0x3

    11.Early MCTP messages via PCIe VDM may cause system suspension (DCSG-18324).

    12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683).

    13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.

  • 新增功能

    1.Implemented the hot upgrade function (DCSG-6354) that can coexist with multiple instance applications.

    2.Fix the PLDM PDR entity difference (DCSG-16320) between the code and DSC2054 specification.

    3.If DCBX is enabled on the NC-SI path, reject LLDP disable request (DCSG-3220).

    4.Added support to allow drivers to change the SGID on the original Ethernet QP (if used for mirroring) in RTR state. The firmware is using modifiy_sqd IM to implement this support (DCSG-31514).

    5.Added 200K support for NTUPLE/KTLS filters in Truflow mode (DCSG-21229).

    6.Added a change to Thor2 based on DCQCN for 1QP solution (DCSG-18660).

    7. Close unused channels (DCSG-26824) in the 400G optical module when operating in 200G mode.

    8. Implemented polling optimization based on RoCE counter set for UDCC to improve tx event rate in low activity QP scenarios (DCSG-24565).

新华三官网
联系我们