• 产品与解决方案
  • 行业解决方案
  • 服务
  • 支持
  • 合作伙伴
  • 新华三人才研学中心
  • 关于我们
首页 支持 文档与软件 软件下载 服务器

R4700 G7 BIOS(2026/6/3)

类型:

Firmware-BIOS

版本:

7.00.26P01

操作系统:

N/A-N/A

    说明

  • 说明
  • 安装步骤
  • 发布说明
  • 解决问题
  • 新增功能
  • 历史版本
  • 说明

    This software is used to upgrade the BIOS version of the R4700 G7 server

  • 安装步骤

  • 发布说明

    Supported products

    H3C UniServer R4700 G7

    Restrictions and cautions

    Restrictions

    Due to Server restart mechanism optimization, the BIOS firmware will not retain configurations when downgrading to a version below 7.00.25. To restore the original configuration after downgrading, you must export the configuration file of the current version through the HDM interface before downgrading, then perform a forced overwrite downgrade using the target lower version. After the downgrade is completed, re-import the previously backed-up configuration file to complete the configuration recovery.

    Guidelines

    To avoid BIOS boot failures, do not upgrade or reset HDM during BIOS boot.

    In BIOS-7.00.11 and later versions, the options for the PCIE Network Configuration menu cannot be properly configured and retained. This issue is resolved in BIOS-7.00.21 and later versions.

    Version information

    Version number

    Version 7.00.26P01

    Image file name and MD5 checksum:

    BIOS-7.00.26P01-signed.bin: d1ede4a1b3a597f79ee67359a0ca3c5a

    You can access the HDM Web interface of the server to identify the BIOS firmware version in the Device information section of the Dashboard page, as shown in Figure 1.

    Figure 1 Viewing the BIOS version number from HDM

    图片 237

     

    BIOS built-in software version

    Table 1 SP CPU BIOS built-in software version

    Item

    Version

    Microcode

    GNR B* Production MCU: m_95_a06d1_01000423.inc

    GNR R1S B* Production MCU: m_20_a06d1_0a000142.inc

    SRF C* Production MCU: m_01_a06f3_030003a3.inc

    Intel BKC version

    2026_WW09

    Intel RC version

    3545P22+reverts*

    BIOS ACTM

    GNR V02.00.406

    SRF V02.00.407

    RSTe PreOS Components

    9.0.0.1240

    VMD VROC

    9.1.0.1139

    Production BIOS ACM / Production SINIT ACM Binaries

    v1.0.8

    Seamloader version

    2.0.01.00.316

    TDX module version

    GNR 2.0.16.00.994

    SRF 1.5.28.04.989

     

    Supported languages

    English

    Chinese

    Supported devices

    Hardware series

    PUID

    H3C UniServer R4300 G7

    R4300-G7-MAL0

    H3C UniServer R4700 G7

    R4700-G7-MAL0

    R4700-G7-MAS0

    R4700-G7-MCL0

    R4700-G7-MCS0

    H3C UniServer R4900 G7

    R4900-G7-MAE0

    R4900-G7-MCE0

    R4900-G7-MAL0

    R4900-G7-MCL0

    R4900-G7-MAS0

    R4900-G7-MCS0

    H3C UniServer R6900 G7

    R6900-G7-MAS0

     

    Hardware and software compatibility matrixes

    CAUTION:

    To avoid update failure, verify the hardware and software compatibility before performing an update.

     

    Table 2 Hardware and software compatibility matrix for H3C UniServer R4300 G7

    Item

    Specifications

    Product family

    H3C UniServer R4300 G7

    HDM

    HDM3-2.13.02 and later

    CPLD

    V003 and later

    iMC

    N/A

     

    Table 3 Hardware and software compatibility matrix for H3C UniServer R4700 G7/R4900 G7

    Item

    Specifications

    Product family

    H3C UniServer R4700 G7/R4900 G7

    HDM

    HDM3-2.13.02 and later

    CPLD

    V003 and later

    iMC

    N/A

     

    Table 4 Hardware and software compatibility matrix for H3C UniServer R6900 G7

    Item

    Specifications

    Product family

    H3C UniServer R6900 G7 Intel

    HDM

    HDM3-3.04.01 and later

    CPLD

    V002 and later

    iMC

    N/A

     

    Table 5 Hardware and software compatibility matrix for H3C UniServer R5300 G7

    Item

    Specifications

    Product family

    H3C UniServer R5300 G7 Intel

    HDM

    HDM3-3.03.01 and later

    CPLD

    V001 and later

    iMC

    N/A

     

    Table 6 Hardware and software compatibility matrix for H3C UniServer R5500 G7 X Intel

    Item

    Specifications

    Product family

    H3C UniServer R5500 G7 X Intel

    HDM

    HDM3-3.04.01 and later

    CPLD

    V001 and later

    iMC

    N/A

     

    Update suggestions

    This version is recommended.

    Update restrictions and guidelines

    Make sure the software versions are compatible with each other.

    To update both HDM and the BIOS, update HDM first.

    Make sure the server is running in stable state before the update. That is, the server is powered off or has entered the operating system.

    If the server enters the OS before the update, you must power cycle the server for the new firmware to take effect.

    If you select the Retain or Restore method to update the BIOS, the update occurs during POST after the server is powered on again. During the update, do not disconnect the power source from the server, or forcedly power off or restart the server.

    If you select the Forcedly restore method to update the BIOS, do not disconnect the power source from the server, or power off or restart the server.

    Selecting the Restore or Forcedly restore method will restore the default BIOS settings, including restoring the boot mode in the BIOS to the default (UEFI).

    During BIOS update with Forcedly restore selected, writing BIOS data, such as restarting the system or saving BIOS configuration from the BIOS setup utility, can cause data write errors. This can lead to BIOS ROM integrity check failures and even system starting failures. If the system prompts Flash Image Broken! System Halt!, forcedly power off the server, and then try to update the BIOS with Forcedly restore selected again.

    As a best practice of bulk update, make sure you can update one server successfully before you update the remaining servers.

  • 解决问题

    Resolved problems in BIOS-7.00.26P01

    202605081237

    Symptom: An FRB2 timeout reboot is triggered when you connect the server to an external device that supports VPD Cap but has invalid VPD field in BIOS-7.00.24 and BIOS-7.00.25. 

    Condition: This symptom might occur if you connect the server to an external device that supports VPD Cap but has invalid VPD field in BIOS-7.00.24 and BIOS-7.00.25.

  • 新增功能

新华三官网