• 产品与解决方案
  • 行业解决方案
  • 服务
  • 支持
  • 合作伙伴
  • 新华三人才研学中心
  • 关于我们
首页 支持 文档与软件 软件下载 服务器

R4950 G6 CPLD(2026/8/7)

类型:

Firmware-CPLD

版本:

011

操作系统:

N/A-N/A

    说明

  • 说明
  • 安装步骤
  • 发布说明
  • 解决问题
  • 新增功能
  • 历史版本
  • 说明

    This software is used to upgrade the CPLD1 version of the R4950 G6 server

  • 安装步骤

  • 发布说明

    Supported products

    H3C Uniserver R4950 G6.

    Restrictions and cautions

    This version is applicable to H3C UniServer R4950 G6 servers.

    Version information

    Version number

    Version number: 011

    The object file name and MD5 checksum for this version:

    RS4M2C10S11011.bin:2554b3ccb0a023144c01f472e09fee29

    You can access the HDM Web interface of the server to identify the version on the System > Product Information page.

    Version history

    Table 1 Version history

    Version number

    Previous version

    Release date

    Version type

    011

    00F

    2026-7-15

    Release version

    00F

    00E

    2025-9-12

    Release version

    00E

    00D

    2025-8-18

    Release version

    00D

    00B

    2025-4-16

    Release version

    00B

    00A

    2024-4-30

    Release version

    00A

    009

    2024-2-7

    Release version

    009

    008

    2023-9-18

    Release version

    008

    007

    2023-7-17

    Release version

    007

    006

    2023-6-10

    Release version

    006

    005

    2023-5-20

    Release version

    005

    004

    2023-5-8

    Alpha version

    004

    003

    2023-3-21

    Alpha version

    003

    002

    2023-1-12

    Alpha version

    002

    001

    2022-12-28

    Alpha version

    001

    001

    2020-10-09

    Alpha version

     

    Hardware and software compatibility matrix

    CAUTION:

    To avoid an upgrade failure, use the following table to verify the hardware and software compatibility before performing an upgrade.

     

    Table 2 Hardware and software compatibility matrix

    Item

    Version

    Model

    H3C UniServer R4950 G6

    System board hardware version

    System board VC version of R4950 G6 server

    CPLD

    R4950 G6 CPLD (0502AAM5) V011

    SCPLD

    R4950 G6 SCPLD (0502AAM3) V00F

    BIOS

    Highest released version of R4950 G6 BIOS (0502AAM2)

    HDM

    Highest released version of R4950 G6 HDM (0502AALU)

     

    Upgrade restrictions and guidelines

    1.Make sure the server and the HDM client (such as a PC) can reach each other.

    2.For a successful bulk update, make sure you can update one server successfully before you update the remaining servers.

    3.During the update process, maintain the network connection and do not refresh the page.

    4.To avoid CPLD or operating system errors, do not power on or power off the server during the firmware.

    Supported Devices

    H3C Uniserver R4950 G6.

    Version Upgrade Recommendation

    This version is recommended for upgrade.

  • 解决问题

    S0 physical button short press shielding;

    Short press event reported to BMC;

    The Predictive hot swapping issue of OCP adapter has been optimized;

    OCP RAS requirements have been adapted;

    P4 resource split x2x2 issue in Option has been adapted;

    AC momentary power interruption issue has been optimized;

    New line-board configurations 4-2/5-2 in Option have been adapted.

    The VR online upgrade function has been adapted;

    The PMIC alarm statement has been optimized;

    The probabilistic identification issue of DSD has been optimized;

    The NIC NCSI timing issue has been optimized;

    The NVMe Drive fault issue has been modified;

    The enabling/disabling ABL serial port print via IPMI at specific sites has been adapted.

    The HDM 's ' slight ' alarm level event state light is ' green light 1Hz flicker ' when adapted to a specific situation.

    The problem of DPU card over-temperature shutdown when upgrading the server BMC version under S5 power supply is solved.

    Adapt to multi host OCP network card configuration on R4950 G6 server.

    Adapt to the self-developed P9560 OCP form of the raid card.

    Solve the problem of 100G OCP network card small fan reporting blockage alarm when powered on or off by DC.

    Added support for power-on of RS46R3X16 RISER S5 Slot2/Slot5 and power-on of general slots.

    Added support for connecting a Marvell M.2 adapter to P4 interface, paired with RS46R3X16, and integrating P4 into the slot loop scheme.

    Resolved the overcurrent protection issue on P12V_STBY PSU that occurred during AC power-on for the Great Wall 1600W Titanium power supply.

    Resolved the issue of the UID LED staying on when the server is powered on through an AC power source.

    Resolved the memory PMIC alarm issue.

  • 新增功能

新华三官网
联系我们