NIC-ETH531F-3S-2P(2025/12/31)

类型:

Firmware-NIC

版本:

234.1.124.0.00

操作系统:

N/A-N/A

    说明

  • 说明
  • 安装步骤
  • 发布说明
  • 解决问题
  • 新增功能
  • 历史版本
  • 说明

    The software is the firmware upgrade program for Broadcom H3C-BCMCD network card version 234.1.124.0.00.

  • 安装步骤

    Restrictions and guidelines

    1.Before updating the software version, it is strongly recommended that you understand the software feature changes between versions, evaluate the potential impact of the changes on your business, and consult relevant supporting materials.

    2.Firmware version 225.3.41.0 and subsequent versions delete the hotkey to enter the interface of the network card OptionRom configuration item under Legacy BIOS, and no longer support the configuration of network card under Legacy BIOS.

    Installation steps

    Linux OS

    1.Log in to the system with an administrator account.

    2.Upload the firmware package (nvmUpgrade_xxx_H3C_Vxx_xxx) to a system-accessible path.

    3.Execute the following command:

    unzip nvmUpgrade_xxx_H3C_Vxx_xxx ##Extract the file

    4.cd nvmUpgrade_xxx_H3C_Vxx_xxx/ ##Enter the extracted file

    5.Execute the following commands:

    chmod 777 -R * ##Grant permission

    ./install.sh --vpd --force ##Execute the firmware upgrade script

    6.After the firmware upgrade is successful, power off the server and restart it to make the new firmware effective.

    7.Entering the system:

    a) Execute the ethtool -i command to check that the NIC firmware version is the target version.

    b) Execute the lspci -vvv -s command to check that the NIC firmware version is the target version.

    Windows OS

    1.Log in to the server operating system with an administrator account.

    2.Upload the firmware package (AutoUpgrade_windows_xxx_H3C_Vxx_xxx) to a system-accessible path.

    3.Extract the firmware package.

    4.Double-click on auto_upgrade_with_vpd.bat and follow the prompts to install.

    5.After the firmware upgrade is successful, power off the server and restart it to make the new firmware effective.

    VMware OS

    1.Log in to the server operating system with an administrator account.

    2.Upload the firmware package (nvmUpgrade_ESXi_xxx_H3C_Vxx_xxx) to a system-accessible path, such as /vmfs/volumes/datastore1/.

    3.Execute the following command:

    unzip nvmUpgrade_ESXi_xxx_H3C_Vxx_xxx ##Extract the file

    cd nvmUpgrade_ESXi_xxx_H3C_Vxx_xxx/ ##Enter the extracted file

    4.Execute the following commands:

    chmod 777 -R * ##Grant permission

    ./install.sh --vpd --force ##Execute the firmware upgrade script

    5.After the firmware upgrade is successful, power off the server and restart it to make the new firmware effective.

    6.Entering the system, execute the esxcli network nic get -n vmnicX command to check that the NIC firmware version is the target version.

  • 发布说明

    Supported products

    H3C UniServer B5700 G3

    H3C UniServer B5700 G5

    H3C UniServer B5800 G3

    H3C UniServer B7800 G3

    H3C UniServer E3200 G3

    H3C UniServer R2700 G3

    H3C UniServer R2900 G3

    H3C UniServer R4300 G3

    H3C UniServer R4300 G5

    H3C UniServer R4330 G5

    H3C UniServer R4330 G5 H3

    H3C UniServer R4500 G3

    H3C UniServer R4700 G3

    H3C UniServer R4700 G5

    H3C UniServer R4700 G6

    H3C UniServer R4900 G3

    H3C UniServer R4900 G5

    H3C UniServer R4900 G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4930 G5

    H3C UniServer R4930 G5 H3

    H3C UniServer R4950 G5

    H3C UniServer R4950 G5 Milan

    H3C UniServer R4950 G5 Rome

    H3C UniServer R4950 G6

    H3C UniServer R5300 G3

    H3C UniServer R5300 G5

    H3C UniServer R5500 G5 AMD

    H3C UniServer R5500 G5 Intel

    H3C UniServer R6700 G3

    H3C UniServer R6900 G3

    H3C UniServer R8900 G3

    H3C UniServer R5350 G6

    H3C UniServer R6900 G5

    H3C UniServer R5500 G6 AMD

    H3C UniServer R5500 G6 Intel

    H3C UniServer R5300 G6

    H3C UniServer R5500LC G5 Intel

    H3C UniServer R5500 G5 HYGON

    H3C UniServer B5700 G6

    H3C UniServer R4900LE G6 Ultra

    H3C UniServer R4700LE G6

    H3C UniServer R4900LC G5

    H3C UniServer R4700LC G5

    H3C UniServer R4930LC G5 H3

    H3C UniServer R4300 G6

    H3C UniServer R4500 G6

    H3C UniServer R6700 G6

    H3C UniServer R6900 G6

    H3C UniServer R5330 G7

    H3C UniServer R5500 G7 Hygon

    H3C UniServer R4930 G7

    H3C UniServer E3300 G6

    H3C UniServer R3950 G6

    H3C UniServer R4330 G7

    H3C UniServer R4950 G7

    H3C UniServer R3950 G7

    H3C UniServer R3350 G7

    H3C UniServer R4900 G7

    H3C UniServer R4700 G7

    H3C UniServer R3900 G7

    H3C UniServer R4300 G7

    Restrictions and guidelines

    1.Before updating the software version, it is strongly recommended that you understand the software feature changes between versions, evaluate the potential impact of the changes on your business, and consult relevant supporting materials.

    2.Firmware version 225.3.41.0 and subsequent versions delete the hotkey to enter the interface of the network card OptionRom configuration item under Legacy BIOS, and no longer support the configuration of network card under Legacy BIOS.

  • 解决问题

    1.Fixed the issue of Niccli recovery failure after resetting from damaged firmware (DCSG-41552);

    2.Fixed communication issue after firmware update when enabling software untag VLAN (DCSG-41528);

    3.Fixed the issue where the PLDM firmware update did not display the image to be updated when the versions of the active and pending images were the same (DCSG-40211);

    4.Fixed the issue where the latest PLDM time could not be sent to BMC (DCSG-37593);

    5.Fixed an issue where sending PCIe VDM MCTP messages too early could cause the system to hang (DCSG-18324);

    6.Fixed the GPIO multiplexing value of OCP Chain pins so that they can be mapped and correctly used for temperature warnings (DCSG-31638);

    7.Fixed the fastboot recovery issue where fastboot recovery (DCSG-30725) is not allowed when lockdown is enabled;

    8.Fixed the issue where the temperature of the transceiver read from eeprom was good, but the is_tempnvalid flag indicated that it was invalid (DCSG-29165);

    9.Fixed LLDP forwarding issue, now always forwarding LLDP packets to BMC (DCSG-29361);

    10.Fixed the issue of not being able to obtain DHCP IP in VM (DCSG-13760);

    11.If DCBX is enabled on the NCSI path, LLDP disable request (DCSG-3220) is rejected.

    12.Whp: Mgmt:To prevent firmware crashes due to a full FIFO (First In, First Out) buffer, using a microsecond timer to adjust timeout calculations can be employed (DCSG-01769683).

    13.The task of periodically updating the heartbeat will be delegated to other processes to prevent firmware crashes.

  • 新增功能

    1.Add support for sending traffic with the same destination MAC address with or without VLAN tagging (DCSG-17231);

    2.Added the function of mirroring traffic on port (RoCE+L2) to the RoCE interface (DCSG-10816);

    3.Added support for enabling/disabling CQ overflow detection (DCSG-9084);

    4.Add support for dbd_cfg parameter (DCSG-15689).