R6700 G6 CPLD(2024/4/25)

类型:

Firmware-CPLD

版本:

V006

操作系统:

N/A-N/A

    说明

  • 说明
  • 安装步骤
  • 发布说明
  • 解决问题
  • 新增功能
  • 历史版本
  • 说明

    This software is used to upgrade main control logic MCPLD of the R6700 G6 server.

  • 安装步骤

  • 发布说明

    Products

    H3C UniServer R6900 G6

    H3C UniServer R6700 G6

    Version information

    Version number

    CPLD version: V006

     

     

    NOTE:

    To view the CPLD version of a drive backplane, access the HDM Web interface of the server, navigate to System > Summary > Others page, as shown in Figure 1 The figure is for illustration only.

     

    Figure 1 Viewing CPLD version

    图片 8

     

    Table 2 Version history

    Version number

    Last version

    Release date

    Version type

    Remarks

    V006

    V005

    2023-12-15

    Release version

    N/A

    V005

    First release

    2023-08-17

    N/A

    N/A

     

    Supported languages

    English.

    Chinese.

    Supported hardware platforms

    H3C UniServer R6900 G6

    H3C UniServer R6700 G6

    Hardware and software compatibility matrix

    CAUTION:

    To avoid an update failure, use the following table to verify the hardware and software compatibility before performing an update.

     

    Table 3 Hardware and software compatibility matrix for H3C UniServer R6900 G6

    Item

    Specifications

    Product family

    H3C UniServer R6900 G6

    System board CPLD1

    V006 or later

    System board CPLD2

    V006 or later

    System board VR

    V003 or later

    Processor mezzanine board DBCPLD

    V006 or later

    HDM

    1.65 or later

    BIOS

    6.00.32 or later

    Image file name and MD5 value

    RS6M2C10S01006.bin: 6b3112dad3dd5fca3b85e35c20088783 (Subject to change according to the latest naming conventions)

    Remarks

    N/A.

     

    (Optional) Version compatibility with ISSU

    None.

    Update recommendation

    This version is required for update.

    Update restrictions and guidelines

    Make sure the server and the HDM client (such as a PC) can reach each other.

    For a successful bulk update, make sure you can update one server successfully before you update the remaining servers.

    During the update, make sure the network connection is available and do not refresh the webpage.

    Do not refresh the page during the update.

    To avoid CPLD or operating system errors, do not power on or power off the server during the firmware update.

    After the firmware is updated, clear the browser cache before you re-log in to HDM.