MSUs

MSU-100

View

Figure2-1 MSU-100 view

(1) Captive screw

(2) DIAG button

(3) USB port

(4) Management Ethernet port

(5) Reset button (RESET)

(6) Console port

(7) Ejector lever

 

LEDs

Figure2-2 MSU-100 LEDs

(1) Management Ethernet copper port LED

(1) System status LED (SYS)

(3) MSU active/standby status LED (ACT)

(4) Fan tray status LED (FAN)

 

Table2-1 LED description

LED

Status

Description

System LED (SYS)

Flashing green (eight times per second)

The device is in BootWare stage or is collecting diagnosis information in Comware stage.

Steady green

The device is in Kernel stage, including Eshell stage.

Flashing green (once per second)

The Comware system is starting up or is operating correctly.

Flashing yellow (once per second)

Memory test failed in BootWare stage.

Flashing yellow (eight times per second)

The extended BootWare segment does not exist.

Steady yellow

The boot.bin file does not exist.

Off

No power input, or an exception has occurred.

MSU active/standby status LED (ACT)

Steady green

The MSU is in active mode.

Flashing green (once per second)

The router is performing an active/standby MSU switchover.

Off

The MSU is in standby mode or initialization state.

Fan tray status LED (FAN)

Steady green

Both fan trays are operating correctly.

Flashing green (once per second)

One fan tray is operating correctly and the other one is not present.

Steady yellow

A minimum of one fan try is faulty.

Off

Both fan trays are not present.

Management Ethernet copper port LED

Steady green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending or receiving data at 1000 Mbps.

Steady yellow

A 10 or 100 Mbps link is present on the port.

Flashing yellow

The port is sending or receiving data at 10 or 100 Mbps.

Off

No link is present on the port.

 

Ports

Table2-2 Port specifications

Port type

Specification

Console port

1

GE management port

1

USB port

1

DIAG button

1

 

Technical specifications

Table2-3 Technical specifications

Item

Specification

Net weight

1.54 kg (3.40 lb)

Dimensions (H × W × D)

42.6 × 375 × 227 mm (1.68 × 14.76 × 8.94 in)

Max power consumption

24.60 W

Memory

4 GB DDR4

Flash

4 GB

Link mode of interfaces

All interfaces can operate only as Layer 3 interfaces

 

MSU-200

View

Figure2-3 MSU-200 view

(1) Captive screw

(2) SIC slot

(3) DIAG button

(4) SFP+ port SFP+10

(5) SFP+ port SFP+11

(6) GE copper ports GE2 to GE9

(7) GE copper port GE1

(8) GE fiber port SFP0

(9) GE fiber port SFP1

(10) USB port

(11) Management Ethernet port

(12) Reset button (RESET)

(13) Console port

(14) Ejector lever

(15) GE copper port GE0

 

LEDs

Figure2-4 MSU-200 LEDs

(1) SFP+ fiber port LED

(2) GE port LED

(3) SFP fiber port LED

(4) Management Ethernet copper port LED

(5) System status LED (SYS)

(6) MSU active/standby status LED (ACT)

(7) Fan tray status LED (FAN)

 

Table2-4 LED description

LED

Status

Description

System LED (SYS)

Flashing green (eight times per second)

The device is in BootWare stage or is collecting diagnosis information in Comware stage.

Steady green

The device is in Kernel stage, including Eshell stage.

Flashing green (once per second)

The Comware system is starting up or is operating correctly.

Flashing yellow (once per second)

Memory test failed in BootWare stage.

Flashing yellow (eight times per second)

The extended BootWare segment does not exist.

Steady yellow

The boot.bin file does not exist.

Off

No power input, or an exception has occurred.

MSU active/standby status LED (ACT)

Steady green

The MSU is in active mode.

Flashing green (once per second)

The router is performing an active/standby MSU switchover.

Off

The MSU is in standby mode or initialization state.

Fan tray status LED (FAN)

Steady green

Both fan trays are operating correctly.

Flashing green (once per second)

One fan tray is operating correctly and the other one is not present.

Steady yellow

A minimum of one fan try is faulty.

Off

Both fan trays are not present.

SFP+ fiber port LED

Steady green

A 10 Gbps link is present on the port.

Flashing green

The port is sending or receiving data at 10 Gbps.

Steady yellow

A 1000 Mbps link is present on the port.

Flashing yellow

The port is sending or receiving data at 1000 Mbps.

Off

No link is present on the port.

SFP fiber port LED

Steady green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending or receiving data at 1000 Mbps.

Steady yellow

A 100 Mbps link is present on the port.

Flashing yellow

The port is sending or receiving data at 100 Mbps.

Off

No link is present on the port.

GE port LED/Management Ethernet copper port LED

Steady green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending or receiving data at 1000 Mbps.

Steady yellow

A 10 or 100 Mbps link is present on the port.

Flashing yellow

The port is sending or receiving data at 10 or 100 Mbps.

Off

No link is present on the port.

 

Ports

Table2-5 Port specifications

Port type

Specification

Console port

1

GE management port

1

GE copper port

8

Combo interface

2 (SFP0/GE0, SFP1/GE1)

SFP+ fiber port

2

USB port

1

DIAG button

1

SIC slot

1

 

Technical specifications

Table2-6 Technical specifications

Item

Specification

Net weight

1.72 kg (3.79 lb)

Dimensions (H × W × D)

42.6 × 375 × 227 mm (1.68 × 14.76 × 8.94 in)

Max power consumption

45.00 W

Memory

4 GB DDR4

Flash

4 GB

Link mode of interfaces

All interfaces can operate only as Layer 3 interfaces

 

MSU-400-G

View

Figure2-5 MSU-400-G view

(1) Captive screw

(2) Management Ethernet port

(3) SFP+ ports SFP+8 to SFP+17

(4) GE copper ports GE0 to GE7

(5) Cloud cluster management SFP+ fiber port

(6) USB port

(7) Reset button (RESET)

(8) Locking clip

(9) Ejector lever

(10) Console port

(11) DIAG button

 

LEDs

Figure2-6 MSU-400-G LEDs

(1) Management Ethernet copper port LED

(2) SFP+ fiber port LED

(3) GE port LED

(4) Cloud cluster management SFP+ fiber port LED

(5) System status LED (SYS)

(6) MSU active/standby status LED (ACT)

(7) Fan tray status LED (FAN)

 

Table2-7 LED description

LED

Status

Description

System LED (SYS)

Flashing green (eight times per second)

The device is in BootWare stage or is collecting diagnosis information in Comware stage.

Steady green

The device is in Kernel stage, including Eshell stage.

Flashing green (once per second)

The Comware system is starting up or is operating correctly.

Flashing yellow (once per second)

Memory test failed in BootWare stage.

Flashing yellow (eight times per second)

The extended BootWare segment does not exist.

Steady yellow

The boot.bin file does not exist.

Off

No power input, or an exception has occurred.

MSU active/standby status LED (ACT)

Steady green

The MSU is in active mode.

Flashing green (once per second)

The router is performing an active/standby MSU switchover.

Off

The MSU is in standby mode or initialization state.

Fan tray status LED (FAN)

Steady green

Both fan trays are operating correctly.

Flashing green (once per second)

One fan tray is operating correctly and the other one is not present.

Steady yellow

A minimum of one fan try is faulty.

Off

Both fan trays are not present.

Cloud cluster management SFP+ fiber port LED

SFP+ fiber port LED

Steady green

A 10 Gbps link is present on the port.

Flashing green

The port is sending or receiving data at 10 Gbps.

Steady yellow

A 1000 Mbps link is present on the port.

Flashing yellow

The port is sending or receiving data at 1000 Mbps.

Off

No link is present on the port.

GE port LED/Management Ethernet copper port LED

Steady green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending or receiving data at 1000 Mbps.

Steady yellow

A 10 or 100 Mbps link is present on the port.

Flashing yellow

The port is sending or receiving data at 10 or 100 Mbps.

Off

No link is present on the port.

 

Ports

Table2-8 Port specifications

Port type

Specification

Console port

1

GE management port

1

GE copper port

8

SFP+ fiber port

11 (including one cloud cluster management port)

USB port

1

DIAG button

1

 

Technical specifications

Table2-9 Technical specifications

Item

Specification

Net weight

2.2 kg (4.85 lb)

Dimensions (H × W × D)

42.6 × 375 × 227 mm (1.68 × 14.76 × 8.94 in)

Max power consumption

121.30 W

Memory

8 GB DDR4

Flash

4 GB

Link mode of interfaces

·     Interfaces that can operate only as Layer 3 interfaces:

¡     Management Ethernet port

¡     Cloud cluster management SFP+ fiber port

·     Interfaces that support link mode change:

¡     Ports SFP+8 to SFP+17

¡     GE copper ports GE0 to GE7

 

Interface modules

Weights, dimensions, and power consumptions

Table2-10 Weights, dimensions, and power consumptions

Module model

Net weight

Max power consumption

Dimensions (H × W × D)

RT-SIC-5G

0.25 kg (0.55 lb)

7.60 W

19.8 × 80 × 138 mm (0.78 × 3.15 × 5.43 in)

RT-XMIM-8GEE

0.72 kg (1.59 lb)

12.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-8GEE-R

0.65 kg (1.43 lb)

8.80 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-8GEF

0.72 kg (1.59 lb)

14.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-8GEF-R

0.65 kg (1.43 lb)

13.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-4XP

0.75 kg (1.65 lb)

20.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-2XPF

0.76 kg (1.68 lb)

15.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-1POS

0.60 kg (1.32 lb)

9.70 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-2POS

0.60 kg (1.32 lb)

10.30 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-1CPOS

0.64 kg (1.41 lb)

11 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-2E1

0.60 kg (1.32 lb)

5.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-4E1

0.65 kg (1.43 lb)

5.40 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-XMIM-8E1

0.65 kg (1.43 lb)

6.80 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

RT-SSD-960G

0.50 kg (1.10 lb)

11.00 W

19.8 × 186 × 228 mm (0.78 × 7.32 × 8.98 in)

 

Interface modules

The device supports SIC interface modules, XMIM interface modules, and SSD modules. For more information about the views, LEDs, and specifications of the interface modules, see H3C MSR Router Series Interface Module Guide (V9).

Power supplies

The device supports AC power supplies, DC power supplies, and mix of AC and DC power supplies. The power supplies can be hot swapped and configured in redundancy. In AC or DC power supply mode, you can install only one power supply, or two or three power supplies for 1+1 or 1+2 power supply redundancy respectively. In mixed power supply mode, you can install two power supplies, or three power supplies for 2+1 power supply redundancy.

The device supports only mix of 450 W AC and DC power supplies.

PSR250-12A

View

Figure2-7 PSR250-12A power supply view

(1) Latch

(2) Handle

(3) Power receptacle

 

LEDs

Figure2-8 PSR250-12A AC power supply LEDs

(1) Status LED

 

Table2-11 LED description

LED

Status

Description

Status LED

Steady green

The power supply is operating correctly.

Flashing green

The power supply has normal power input but has not been turned on.

Steady red

The power supply is faulty or has entered protection state.

Alternating between red and green

An alarm is present on the power supply.

Flashing red

This power supply does not have power input but the other power supply has power input.

Off

No power is present.

 

Technical specifications

Table2-12 Technical specifications

Item

Specification

Net weight

0.64 kg (1.41 lb)

Dimensions (H × W × D)

40 × 51 × 221 mm (1.57 × 2.01 × 8.70 in)

Rated input voltage

·     100 to 240 VAC @ 50 or 60 Hz

·     240 VDC

Input voltage range

·     90 VAC to 290 VAC @ 50 or 60Hz

·     180 VDC to 320 VDC

Max input current

·     4 A (AC input)

·     2 A (DC input)

Max power

250 W

 

PSR450-12A

View

Figure2-9 PSR450-12A power supply view

(1) Latch

(2) Handle

(3) Power receptacle

 

LEDs

Figure2-10 PSR450-12A AC power supply LEDs

(1) Status LED

 

Table2-13 LED description

LED

Status

Description

Status LED

Steady green

The power supply is operating correctly.

Flashing green

The power supply has normal power input but has not been turned on.

Steady red

The power supply is faulty or has entered protection state.

Alternating between red and green

An alarm is present on the power supply.

Flashing red

This power supply does not have power input but the other power supply has power input.

Off

No power is present.

 

Technical specifications

Table2-14 Technical specifications

Item

Specification

Net weight

0.65 kg (1.43 lb)

Dimensions (H × W × D)

40 × 51 × 221 mm (1.57 × 2.01 × 8.70 in)

Rated input voltage

·     100 to 240 VAC @ 50 or 60 Hz

·     240 VDC

Input voltage range

·     90 VAC to 290 VAC @ 50 or 60Hz

·     180 VDC to 320 VDC

Max input current

·     6 A (AC input)

·     3 A (DC input)

Max power

450 W

 

PSR450-12A2-F

View

Figure2-11 PSR450-12A2-F power supply view

(1) Latch

(2) Handle

(3) Power receptacle

 

LEDs

Figure2-12 PSR450-12A2-F AC power supply LEDs

(1) Status LED

 

Table2-15 LED description

LED

Status

Description

Status LED

Steady green

The power supply is operating correctly.

Flashing green

The power supply has normal power input but has not been turned on.

Steady red

The power supply is faulty or has entered protection state.

Alternating between red and green

An alarm has occurred when one of the following conditions exists on the power supply but the power supply does not enter protection state:

·     Output overcurrent.

·     Output power overload.

·     Overtemperature.

Flashing red

·     The power supply does not have power input. If two power supplies are installed and only one power supply has power input, the status LED of the power supply that does not have power input flashes red.

·     The power supply is in input undervoltage protection state.

Off

The power supply does not have power input.

 

Technical specifications

Table2-16 Technical specifications

Item

Specification

Net weight

0.66 kg (1.46 lb)

Dimensions (H × W × D)

40 × 51 × 221 mm (1.57 × 2.01 × 8.70 in)

Rated input voltage

·     100 to 240 VAC @ 50 or 60 Hz

·     240 VDC

Input voltage range

·     90 VAC to 290 VAC @ 50 or 60Hz

·     180 VDC to 320 VDC

Max input current

·     6 A (AC input)

·     3 A (DC input)

Max power

450 W

 

PSR450-12D-F

View

Figure2-13 PSR450-12D-F power supply view

(1) Latch

(2) Handle

(3) Power receptacle

 

LEDs

Figure2-14 PSR450-12D-F DC power supply LEDs

(1) Status LED

 

Table2-17 LED description

LED

Status

Description

Status LED

Steady green

The power supply is operating correctly.

Flashing green

The power supply has normal power input but has not been turned on.

Steady red

The power supply is faulty or has entered protection state.

Alternating between red and green

An alarm is present on the power supply.

Flashing red

This power supply does not have power input but the other power supply has power input.

Off

No power is present.

 

Technical specifications

Table2-18 Technical specifications

Item

Specification

Net weight

0.68 kg (1.50 lb)

Dimensions (H × W × D)

40 × 51 × 221 mm (1.57 × 2.01 × 8.70 in)

Rated input voltage

–48 VDC to –60 VDC

Input voltage range

–36 VDC to –72 VDC

Max input current

12 A to 10 A

Max power

450 W

 

PSR450-12D1-F

View

Figure2-15 PSR450-12D1-F power supply view

(1) Latch

(2) Handle

(3) Power receptacle

 

LEDs

Figure2-16 PSR450-12D1-F DC power supply LEDs

(1) Status LED

 

Table2-19 LED description

LED

Status

Description

Status LED

Steady green

The power supply is operating correctly.

Flashing green

The power supply has normal power input but has not been turned on.

Steady red

The power supply is faulty or has entered protection state.

Alternating between red and green

An alarm has occurred when one of the following conditions exists on the power supply but the power supply does not enter protection state:

·     Output overcurrent.

·     Output power overload.

·     Overtemperature.

Flashing red

·     The power supply does not have power input. If two power supplies are installed and only one power supply has power input, the status LED of the power supply that does not have power input flashes red.

·     The power supply is in input undervoltage protection state.

Off

The power supply does not have power input.

 

Technical specifications

Table2-20 Technical specifications

Item

Specification

Net weight

0.64 kg (1.41 lb)

Dimensions (H × W × D)

40 × 51 × 221 mm (1.57 × 2.01 × 8.70 in)

Rated input voltage

–48 VDC to –60 VDC

Input voltage range

–36 VDC to –72 VDC

Max input current

12 A to 10 A

Max power

450 W

 

Fan trays

FAN-80B-2-C

View

Figure2-17 FAN-80B-2-C fan tray view

(1) Handle

 

LEDs

Figure2-18 FAN-80B-2-C fan tray LEDs

(1) Status LED

 

Table2-21 LED description

LED

LED status

Description

RUN

Steady green

The fan tray is operating correctly.

Steady yellow

The fan tray is faulty.

Off

The fan tray is not present or has no power input.

 

Technical specifications

Table2-22 Technical specifications

Item

Specification

Net weight

1.06 kg (2.34 lb)

Dimensions (H × W × D)

171 × 136 × 93 mm (6.73 × 5.35 × 3.66 in)

Max power consumption

55 W

Number of fans

2

Automatic speed adjustment

Supported

Anti-misinsertion

Supported

Hot swapping

Supported

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us