- Table of Contents
- Related Documents
-
| Title | Size | Download |
|---|---|---|
| 01-About the Router | 1.23 MB |
1 About the router
Unless otherwise stated, MSUs, SIC interface modules, XMIM interface modules, and SSD modules are collectively referred to as "modules" in this document.
"MSU" in this document refers to the main-control and service-processing unit.
Chassis views
The figures in this section are for illustration only.
Figure1-1 MSR5680-X3 front panel
|
(1) Interface module slot 2 |
(2) Interface module slot 4 |
|
(3) Interface module slot 3 |
(4) Interface module slot 5 |
|
(5) MSU slot 0 |
(6) MSU slot 1 |
|
(7) Power supply slot PWR2 |
(8) Power supply slot PWR1 |
|
(9) Power supply slot PWR0 |
(10) Interface module slot 7 |
|
(11) Interface module slot 9 |
(12) Interface module slot 6 |
|
(13) Interface module slot 8 |
|
Figure1-2 MSR5680-X3 rear panel
|
(1) Fan tray slot 0 |
(2) Fan tray slot 1 |
|
(3) Grounding screw |
|
Slot arrangement and interface numbering
Slot arrangement
Table1-1 Slot arrangement on the device
|
Model |
Slot arrangement |
|
MSR5680-X3 |
|
|
MSU-200 |
|
Interface numbering
Conventions
The interfaces (except the management Ethernet interface) on the device are numbered in the interface-type X/Y/Z format. The management Ethernet interface number is M-GigabitEthernet 0/0/0.
· interface-type—Type of the interface such as GigabitEthernet and Ten-GigabitEthernet.
· X—Slot number, as shown in Table1-1.
¡ For an MSU or XMIM interface module, X represents the number of the slot where the module resides on the device.
¡ For an SIC interface module, X represents the number of the slot where the MSU resides on the device.
· Y—Subslot number.
¡ For an MSU or XMIM interface module, the number is fixed at 0.
¡ For an SIC interface module, the number is fixed at 1.
· Z—Interface number.
¡ For an MSU or XMIM interface module, Z represents the number of the interface on the module.
¡ For a SIC-5G interface module, the number for the SIM1 slot is 0, and the number for the SIM2 slot is 1.
Examples
An XMIM-8GEE-R interface module is installed in slot 6 of the device. Fixed GE copper ports on the interface module are numbered GigabitEthernet 6/0/0 through GigabitEthernet 6/0/7, respectively.
An MSU-200 is installed in slot 0 of the device and a SIC-5G interface module is installed on the MSU. Fixed SFP+ fiber ports on MSU-200 are numbered Ten-GigabitEthernet 0/0/10 and Ten-GigabitEthernet 0/0/11, respectively. Ports on the SIC-5G interface module are numbered Cellular 0/1/0 and Cellular 0/1/1, respectively.
Technical specifications
Table1-2 MSR5680-X3 technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) (excluding rubber feet and mounting brackets) |
175 × 440 × 330 mm (6.89 × 17.32 × 12.99 in) |
|
Chassis weight (including mounting brackets and filler panels) |
10.62 kg (23.41 lb) |
|
Chassis weight (fully configured) |
22.5 kg (49.60 lb) |
|
Device weight |
Weights of the chassis (including mounting brackets and filler panels), modules, power supplies, fan trays, and other removable components |
|
System power consumption |
Total power consumption of all modules and fan trays |
|
Heat dissipation |
Heat dissipation of the router per hour is 0.9 × (total power consumption of all modules and fan trays)/0.9 × 3.4121 |
|
MSU slots |
2 |
|
XMIM interface module/SSD module slots |
8 |
|
Fan tray slots |
2 |
|
Power supply slots |
3 |
|
Operating temperature |
0°C to 45°C (32°F to 113°F) |
|
Operating humidity |
5% RH to 95% RH, noncondensing |
|
|
NOTE: Heat dissipation is measured in BTU/h. 1 W equals 3.4121 BTU/h. |