- Table of Contents
- Related Documents
-
| Title | Size | Download |
|---|---|---|
| 05-Appendix B LEDs | 160.98 KB |
5 Appendix B LEDs
The RA5100 and RA5100-HI routers have the same LEDs. This section describes the RA5100-HI router LEDs.
Figure5-1 RA5100 router LEDs
|
(1) System status LED (SYS) |
(2) Running status LED (RUN) |
|
(3) Clock synchronization LED (SYNC) |
(4) High severity alarm LED (ALARM H) |
|
(5) Low severity alarm LED (ALARM L) |
(6) 10GE fiber port LEDs |
|
(7) GE fiber port LEDs |
(8) GE copper port LEDs |
|
(9) Management Ethernet port LED |
(10) Power supply LEDs |
Table5-2 LED descriptions
|
LED |
Status |
Description |
|
Flashing green at 8 Hz |
· BIOS stage—BIOS is starting up. · BootWare stage—The system software image is being decompressed. |
|
|
Flashing yellow at 1 Hz |
· BIOS stage—The memory does not exist or system initialization has failed. · BootWare stage—The SDRAM has failed the POST. |
|
|
Flashing yellow at 8 Hz |
The extended segment does not exist (BIOS stage). |
|
|
Steady green |
· BootWare stage—The SDRAM is being tested. · Comware stage—The kernel is starting up. |
|
|
Flashing green at 1 Hz |
The Comware system is starting up or is operating correctly (Comware stage). |
|
|
Steady yellow |
The boot.bin file does not exist (BootWare stage). |
|
|
Off |
A system hardware failure has occurred. |
|
|
Flashing green at 1 Hz |
BIOS has started up and BootWare is starting up. |
|
|
Flashing red at 1 Hz |
BIOS is starting up. |
|
|
Steady green |
The Comware system is starting up or is operating correctly. |
|
|
Off |
No power is present. |
|
|
Steady green |
· The system clock is in free-run mode and no clock source is specified for the system clock. · The system clock is in traced mode and is tracing a clock source in the clock source priority list. · The system clock is in locked mode, and the PTP clock is tracing a clock source. |
|
|
Steady yellow |
· The system has lost all its clock sources except the internal clock source. The system clock is in holdover mode or free-run mode. · The system clock is in locked mode but no clock source is available. The PTP clock is in holdover mode or free-run mode. |
|
|
Off |
No power is present, or the system clock is not synchronized during system startup. |
|
|
Steady red |
A high severity alarm has occurred on the device. |
|
|
Off |
No high severity alarm has occurred on the device. |
|
|
Steady yellow |
A low severity alarm has occurred on the device. |
|
|
Off |
No low severity alarm has occurred on the device. |
|
|
Steady green |
A 10GE link is present on the port. |
|
|
Flashing green |
The port is sending or receiving data at 10 Gbps. |
|
|
Steady yellow |
A GE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 1 Gbps. |
|
|
Off |
No link is present on the port. |
|
|
Steady green |
A GE link is present on the port. |
|
|
Flashing green |
The port is sending or receiving data at 1 Gbps. |
|
|
Steady yellow |
An FE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
Steady green |
A GE link is present on the port. |
|
|
Flashing green |
The port is sending or receiving data at 1 Gbps. |
|
|
Steady yellow |
A FE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
Steady green |
A GE link is present on the port. |
|
|
Flashing green |
The port is sending or receiving data at 1 Gbps. |
|
|
Steady yellow |
An FE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
Steady green |
The power supply is operating correctly. |
|
|
Off |
No power is present. |

