01-Fundamentals

HomeSupportReference GuidesMIB CompanionH3C S6800 & S6860 Switch Series MIB Companion-Release 671x-6W10001-Fundamentals
05-HH3C-UI-MAN-MIB
Title Size Download
05-HH3C-UI-MAN-MIB 67.21 KB

HH3C-UI-MAN-MIB

About this MIB

Use this MIB to define alarms on user authentication. This MIB also contains notifications about user login changes.

MIB file name

hh3c-ui-man.mib

Root object

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cCommon(2).hh3cUIMgt(2)

Scalar objects

hh3cTerminalUserName

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTerminalUserName (1.3.6.1.4.1.25506.2.2.1.1.2.1)

accessible-for-notify

DisplayString

Standard MIB values.

Name of a login user.

As per the MIB.

 

hh3cTerminalSource

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTerminalSource (1.3.6.1.4.1.25506.2.2.1.1.2.2)

accessible-for-notify

DisplayString

Standard MIB values.

Login method, including Console, AUX, TTY, and VTY.

As per the MIB.

 

hh3cTerminalUserAuthFailureReason

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cTerminalUserAuthFailureReason (1.3.6.1.4.1.25506.2.2.1.1.2.3)

accessible-for-notify

INTEGER

exceedRetries(1)

authTimeout(2)

otherReason(3)

Failure reason for user authentication.

As per the MIB.

 

hh3cVtyCurrentVty

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cVtyCurrentVty (1.3.6.1.4.1.25506.2.2.1.1.2.4)

accessible-for-notify

Unsigned32

Standard MIB values.

Number of used VTY lines.

As per the MIB.

hh3cVtyMaxVty

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cVtyMaxVty (1.3.6.1.4.1.25506.2.2.1.1.2.5)

accessible-for-notify

Unsigned32

Standard MIB values.

Maximum number of VTY lines that the system allows users to log in to concurrently.

As per the MIB.

hh3cVtyThreshold

Object (OID)

Access

Syntax

Value range

Description

Implementation

hh3cVtyThreshold (1.3.6.1.4.1.25506.2.2.1.1.2.6)

accessible-for-notify

Unsigned32

Standard MIB values.

VTY usage alarm threshold.

As per the MIB.

 

Notifications

The following information describes the notifications included in the HH3C-UI-MAN-MIB module.

hh3cLogIn

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.2.1.1.3.0.1

User login

Informational

-

-

ON

 

Description

This notification is generated when a user logs in to the system.

Status control

This alarm cannot be cleared.

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.2.1.1.2.1 (hh3cTerminalUserName)

Username.

No

DisplayString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.2.1.1.2.2 (hh3cTerminalSource)

User line, including console, AUX, TTY, and VTY.

No

DisplayString

OCTET STRING (SIZE (0..255))

 

This table does not contain indexes. For information about the index or indexes of a MIB object instance in an SNMP variable binding, see the section for that MIB object.

Recommended action

No action is required.

hh3cLogOut

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.2.1.1.3.0.2

User logout

Informational

-

-

ON

 

Description

This notification is generated when a user logs out of the system.

Status control

This alarm cannot be cleared.

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.2.1.1.2.1 (hh3cTerminalUserName)

Username.

No

DisplayString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.2.1.1.2.2 (hh3cTerminalSource)

User line, including AUX, TTY, and VTY.

No

DisplayString

OCTET STRING (SIZE (0..255))

 

This table does not contain indexes. For information about the index or indexes of a MIB object instance in an SNMP variable binding, see the section for that MIB object.

Recommended action

No action is required.

hh3cLogInAuthenFailure

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.2.1.1.3.0.3

User authentication failed

Informational

-

-

ON

 

Description

This notification is generated when a user failed to log in to the system.

Status control

This alarm cannot be cleared.

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.2.1.1.2.1 (hh3cTerminalUserName)

Username.

No

DisplayString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.2.1.1.2.2 (hh3cTerminalSource)

User line, including AUX, TTY, and VTY.

No

DisplayString

OCTET STRING (SIZE (0..255))

1.3.6.1.4.1.25506.2.2.1.1.2.3 (hh3cTerminalUserAuthFailureReason)

Failure reason for user authentication.

No

INTEGER

exceedRetries(1)

authTimeout(2)

otherReason(3)

 

This table does not contain indexes. For information about the index or indexes of a MIB object instance in an SNMP variable binding, see the section for that MIB object.

Recommended action

No action is required.

hh3cVtyUsageExceed

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.2.1.1.3.0.4

The number of used VTY lines reached or exceeded the alarm threshold.

Informational

-

-

ON

 

Description

This notification is generated when the number of used VTY lines reaches or exceeds the alarm threshold.

Status control

This alarm cannot be disabled.

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.2.1.1.2.4

(hh3cVtyCurrentVty)

Number of used VTY lines.

No

Integer

Standard MIB values.

1.3.6.1.4.1.25506.2.2.1.1.2.5

(hh3cVtyMaxVty)

Maximum number of VTY lines that the system allows users to log in to concurrently.

No

Integer

Standard MIB values.

1.3.6.1.4.1.25506.2.2.1.1.2.6

(hh3cVtyThreshold)

VTY usage alarm threshold.

No

Integer

Standard MIB values.

 

Recommended action

Release user lines.

hh3cVtyUsageResume

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.4.1.25506.2.2.1.1.3.0.5

VTY usage alarm was cleared.

Informational

-

-

ON

 

Description

This notification is generated when the number of used VTY lines drops below the VTY usage alarm threshold.

Status control

This alarm cannot be disabled.

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.4.1.25506.2.2.1.1.2.4

(hh3cVtyCurrentVty)

Number of used VTY lines.

No

Integer

Standard MIB values.

1.3.6.1.4.1.25506.2.2.1.1.2.5

(hh3cVtyMaxVty)

Maximum number of VTY lines that the system allows users to log in to concurrently.

No

Integer

Standard MIB values.

1.3.6.1.4.1.25506.2.2.1.1.2.6

(hh3cVtyThreshold)

VTY usage alarm threshold.

No

Integer

Standard MIB values.

 

Recommended action

No action is required.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网