07-Layer 3—IP Services Configuration Guide

HomeSupportConfigure & DeployConfiguration GuidesH3C MSR810[2600][3600] Routers Configuration Guides(V7)-R0809-6W40007-Layer 3—IP Services Configuration Guide
22-Lighttpd service configuration
Title Size Download
22-Lighttpd service configuration 46.18 KB

Configuring lighttpd Web services

About lighttpd Web services

The device can act as a lighttpd Web server to support lightweight Web access to resources saved on the device. Supported resources include PHP dynamic webpages, pictures, flash files, video files, and advertisements. To access the resources on the lighttpd Web server, users only need to launch a Web browser and enter the IP address of the device in the address bar.

Restrictions: Hardware compatibility with Lighttpd Web service

Hardware

Lighttpd Web service compatibility

MSR810, MSR810-W, MSR810-W-DB, MSR810-LM, MSR810-W-LM, MSR810-10-PoE, MSR810-LM-HK, MSR810-W-LM-HK, MSR810-LM-CNDE-SJK, MSR810-CNDE-SJK

Yes

MSR810-LMS, MSR810-LUS

No

MSR810-LMS-EA, MSR810-LME

Yes

MSR2600-6-X1, MSR2600-10-X1

No

MSR 2630

No

MSR3600-28, MSR3600-51

No

MSR3600-28-SI, MSR3600-51-SI

No

MSR3600-28-X1, MSR3600-28-X1-DP, MSR3600-51-X1, MSR3600-51-X1-DP

No

MSR3610-I-DP, MSR3610-IE-DP, MSR3610-IE-ES, MSR3610-IE-EAD

No

MSR3610-X1, MSR3610-X1-DP, MSR3610-X1-DC, MSR3610-X1-DP-DC

No

MSR 3610, MSR 3620, MSR 3620-DP, MSR 3640, MSR 3660

No

MSR3610-G, MSR3620-G

No

Hardware

Lighttpd Web service compatibility

MSR810-W-WiNet, MSR810-LM-WiNet

Yes

MSR830-4LM-WiNet

Yes

MSR830-5BEI-WiNet, MSR830-6EI-WiNet, MSR830-10BEI-WiNet

Yes

MSR830-6BHI-WiNet, MSR830-10BHI-WiNet

Yes

MSR2600-6-WiNet , MSR2600-10-X1-WiNet

No

MSR2630-WiNet

No

MSR3600-28-WiNet

No

MSR3610-X1-WiNet

No

MSR3610-WiNet, MSR3620-10-WiNet, MSR3620-DP-WiNet, MSR3620-WiNet, MSR3660-WiNet

No

Hardware

Lighttpd Web service compatibility

MSR2630-XS

No

MSR3600-28-XS

No

MSR3610-XS

No

MSR3620-XS

No

MSR3610-I-XS

No

MSR3610-IE-XS

No

Hardware

Lighttpd Web service compatibility

MSR810-LM-GL

Yes

MSR810-W-LM-GL

Yes

MSR830-6EI-GL

Yes

MSR830-10EI-GL

Yes

MSR830-6HI-GL

Yes

MSR830-10HI-GL

Yes

MSR2600-6-X1-GL

No

MSR3600-28-SI-GL

No

Restrictions and guidelines: lighttpd Web service configuration

For the lighttpd Web server to provide lightweight HTTP or HTTPS access service correctly, make sure it uses different service ports than other services. By default, the lightweight HTTP service port number is 80 and the lightweight HTTPS service port number is 443.

Prerequisites

For the lighttpd Web server to provide HTTPS access service, save the required certificate to the lighttpd Web service working directory.

Procedure

1.     Enter system view.

system-view

2.     Specify the lighttpd Web service working directory.

light-http server directory directory

By default, no lighttpd Web service working directory is specified.

3.     Save the webpages for users to access to the lighttpd Web service working directory.

4.     Enable the lighttpd Web server.

light-http server enable

By default, the lighttpd Web server is disabled.

5.     (Optional.) Specify the lightweight HTTP service port number.

light-http server http-port port-number

By default, the lightweight HTTP service port number is 80.

6.     (Optional.) Specify the lightweight HTTPS service port number.

light-http server https-port port-number

By default, the lightweight HTTPS service port number is 443.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网