Contents
Installing the switch in a rack
Installing an S5820X-26S switch in a 19-inch rack
Installing an S5820X-28C switch in a 19-inch rack
Installing an S5820X-28S switch in a 19-inch rack
Mounting the switch on a workbench
Connecting the grounding cable
Connecting the grounding cable for an S5820X-26S switch
Connecting the grounding cable for an S5820X-28C or S5820X-28S switch
About this guide
This guide describes the basic installation procedures for the S5820X Switch Series. For more information about the installation and configuration procedures, system description, appearance, LEDs, software loading and upgrading, and troubleshooting, see H3C S5820X Switch Series Installation Guide.
Product overview
The H3C S5820X Switch Series includes the following models:
· S5820X-28S
· S5820X-28C
· S5820X-26S
|
NOTE: The H3C S5820X Switch Series models and installation procedures might be updated without prior notice. For the latest quick start guide, go to http://www.h3c.com.hk. |
Installation site
The switch must be used indoors. Before installation, verify that the rack is sturdy enough to support the switch and its accessories.
To ensure correct operation and long service life of your switch, install it in an environment that meets the temperature, humidity, and electromagnetic shield (EMS) requirements. For more information, see H3C S5820X Switch Series Installation Guide.
Installation tools
The installation tools are not provided with the switch. Prepare them yourself.
Figure 1 Installation tools
(1) ESD wrist strap |
(2) Flat-blade screwdriver |
(3) Phillips screwdriver |
(4) Marker |
(5) Wrench |
(6) Blow dryer |
Installation flow
Figure 2 Installation flow
|
NOTE: The S5820X-28C switch supports hot-swapping of interface cards and OAP cards. You can install or remove an interface card or an OAP card when the switch is operating. For more information, see "Installing an interface card" and "Installing an OAP card." |
Installing the switch in a rack
Attaching an ESD wrist strap
Before installation, wear an ESD strap, and make sure one end of the wrist strap has a good skin contact and the other end is attached to a post of the correctly-grounded rack, as shown in Figure 3.
Figure 3 Attaching an ESD wrist strap
Installation accessories
The S5820X-28S/S5820X-26S switch comes with a pair of 1 U load-bearing mounting brackets. The S5820X-28C switch comes with a pair of 2 U load-bearing mounting brackets, and each mounting bracket is attached with a cable management bracket.
(1) 1 U mounting brackets |
(2) 2 U mounting brackets and cable management brackets |
In addition to a pair of mounting brackets, the S5820X-26S switch also comes with a pair of chassis rails and a pair of slide rails.
Figure 5 Chassis rail and slide rail
(1) Chassis rail |
(2) Slide rail |
Mounting positions
The S5820X-28S and S5820X-28C switches provide three mounting positions: one front mounting position (near the network ports), one mid-mounting position, and one rear mounting position (near the power modules). Figure 6 shows the mounting bracket installation positions on an S5820X-28S switch.
Figure 6 Mounting positions on an S5820X-28S switch
(1) Front mounting position |
(2) Mid-mounting position |
(3) Rear mounting position |
The S5820X-26S switch provides two mounting positions: one front mounting position (near the network ports) and one rear mounting position (near the power modules), as shown in Figure 7.
Figure 7 Mounting positions on an S5820X-26S switch
(1) Front mounting position |
(2) Rear mounting position |
|
NOTE: If a rack shelf is available, you can mount the switch in the rack by using mounting brackets and a rack shelf. Put the switch on the rack shelf and slide the switch to a position according to the mounting bracket installation position. Then secure the switch to the rack. |
Installing an S5820X-26S switch in a 19-inch rack
Table 1 Installing an S5820X-26S switch in a 19-inch rack
Installation procedure |
Remarks |
Installation diagram |
1. Attach the mounting brackets to the switch. |
Required |
· For mounting near the power modules, see Figure 8. · For mounting near the ports, see Figure 9. |
2. Attach chassis rails to the switch. |
Required |
· For mounting near the ports, see Figure 8. · For mounting near the power modules, see Figure 9. |
3. Install cage nuts in the rack posts. |
Required |
See Figure 10. |
4. Attach slide rails to the rack posts. |
Required |
See Figure 11. |
5. Connect the grounding cable to the primary grounding point. |
Optional |
See Figure 12. |
6. Install the switch in the rack. |
Required |
See Figure 13. This figure uses the mounting position near the power modules as an example. |
|
NOTE: · The depth of the rack must be a minimum of 1000 mm (39.37 in). · The S5820X-26S switch has three grounding points, as shown in Figure 19. The primary grounding point and auxiliary grounding point 1 are on the right side panel. If you use one of these grounding points, you must connect the grounding cable to the grounding point before you mount the switch in the rack. |
Figure 8 Installing the mounting brackets near the power modules and installing the chassis rails
Figure 9 Installing the mounting brackets near the ports and installing the chassis rails
Figure 10 Installing cage nuts in a rack post
Figure 11 Attaching slide rails to the rack
Figure 12 Connecting the grounding cable to the primary grounding point
(1) Grounding sign |
(2) Grounding cable |
Figure 13 Installing the switch in the rack (mounting brackets near the power modules)
Installing an S5820X-28C switch in a 19-inch rack
Table 2 Installing an S5820X-28C switch in a 19-inch rack
Installation procedure |
Remarks |
Installation diagram |
1. Separate the mounting brackets from cable management brackets. |
Optional |
See Figure 14. |
2. Attach the mounting brackets to the switch. |
Required |
· For mounting near the ports, see Figure 14. · For mounting in the mid-mounting position, see Figure 14. · For mounting near the power modules, see Figure 14. |
3. Install cage nuts in the rack posts. |
Required |
See Figure 10. |
4. Install the switch in the rack. |
Required |
See Figure 15. |
|
NOTE: Before you install the mounting brackets in the mid-mounting position, separate the mounting brackets from the cable management bracket. |
Figure 14 Attaching mounting brackets to the S5820X-28C switch
(1) Separate the mounting bracket from the cable management bracket |
(2) Install mounting brackets near the ports |
(3) Install mounting brackets in the mid-mounting position |
(4) Install mounting brackets near the power modules |
Figure 15 Installing the switch in the rack
Installing an S5820X-28S switch in a 19-inch rack
Table 3 Installing an S5820X-28S switch in a 19-inch rack
Installation procedure |
Remarks |
Installation diagram |
1. Attach the mounting brackets to the switch. |
Required |
See Figure 16. |
2. Install cage nuts in the rack posts. |
Required |
See Figure 10. |
3. Install the switch in the rack. |
Required |
See Figure 17. |
Figure 16 Attaching the mounting bracket to the switch
(1) Mounting near the ports |
(2) Mounting in the mid-mounting position |
(3) Mounting near the power modules |
Figure 17 Installing the switch in the rack
Mounting the switch on a workbench
|
CAUTION: · Ensure 10 cm (3.94 in) of clearance around the switch. · Do not place heavy objects on the switch. |
If a standard 19-inch rack is not available, you can place you switch on a workbench. The S5820X-26S switch cannot be mounted on a workbench.
To mount the switch on a workbench:
1. Make sure the workbench is clean and correctly grounded.
2. Place the switch with bottom up carefully, and clean the round holes on the chassis bottom with dry cloth.
3. Attach the rubber feet to the four round holes in the chassis bottom.
4. Place the switch with upside up on the workbench.
Figure 18 Mounting the switch on a workbench
Connecting the grounding cable
|
CAUTION: Correctly connecting the switch grounding cable is crucial to lightning protection and EMS of a switch. |
Connecting the grounding cable for an S5820X-26S switch
The S5820X-26S switch has three grounding points, as shown in Figure 19. H3C recommends that you use the primary grounding point.
Figure 19 Grounding points of the S5820X-26S switch
(1) Auxiliary grounding point 2 |
(2) Primary grounding point |
(3) Auxiliary grounding point 1 |
|
To connect the grounding cable for an S5820X-26S switch:
1. Connect one end of the grounding cable to the grounding point on the switch. See Figure 12.
2. Attach the other end (ring terminal) of the grounding cable to a grounding post on the grounding strip, and secure the grounding cable to the grounding post by using a hex nut.
Figure 20 Connecting the grounding cable
Connecting the grounding cable for an S5820X-28C or S5820X-28S switch
The S5820X-28C and S5820X-28S switches have a grounding point at their rear panels. This guide uses the S5820X-28S switch as an example:
To connect the grounding cable:
1. Connect one end of the grounding cable to the grounding point of the switch.
Figure 21 Connecting one end of the grounding cable to the S5820X-28S switch
2. To connect the other end of the grounding cable to a grounding strip:
a. Cut the grounding cable to a length according to the distance between the switch and the grounding strip.
b. Peel 5 mm (0.20 in) of insulation sheath from the end, and then insert the naked metal part through the black insulation covering into the end of the ring terminal.
c. Secure the metal part of the cable to the ring terminal with a crimper, and then cover it with the insulation covering.
d. Heat the insulation covering with a blow dryer to let it completely cover the metal part.
e. Connect the ring terminal to the grounding post of the grounding strip, and then fasten it with a hex nut.
Figure 22 Connecting the other end of the grounding cable to the grounding strip
Installing fan trays
|
CAUTION: You must install two fan trays of the same model on the same switch. |
The switch supports hot-swappable fan trays. Table 4 lists the fan trays available for the switch. For more information about the fan trays, see H3C LSW1FAN & LSW1BFAN Installation Manual and H3C LSWM1FANSC & LSWM1FANSCB Installation Guide.
Switch model |
Shipped with fan trays |
Available fan trays |
Installation diagram |
S5820X-28S |
Yes |
LSW1BFAN |
See Figure 23. |
S5820X-28C |
Yes |
LSW1FAN |
See Figure 24. |
S5820X-26S |
No |
· LSWM1FANSC · LSWM1FANSCB |
See Figure 25. The installation procedures are the same for the LSWM1FANSCB and LSWM1FANSC fan trays. |
Figure 23 Installing an LSW1BFAN fan tray
Figure 24 Installing an LSW1FAN fan tray
Figure 25 Installing an LSWM1FANSC fan tray
Installing power modules
|
CAUTION: · For an S5820X-28C switch, do not remove the filler modules in the power module slots. Before you install a PSR300-12A, PSR300-12A1, PSR300-12A2, PSR300-12D1, or PSR300-12D2 power module on an S5820X-28C switch, make sure the filler module has been installed. · Do not install a 650 W power module (LSVM1AC650 or LSVM1DC650) and a 300 W power module (LSVM1AC300 or LSVM1DC300) on the same S5820X-26S switch. |
The switch provides two power module slots and supports hot-swappable power modules. A power module can meet the power requirements of the switch. You can install two power modules for redundancy.
Table 5 lists the power modules available for these switches. For more information about the power modules, see H3C PSR300-12A & PSR300-12D Series Power Modules User Manual, H3C LSVM1AC650 & LSVM1DC650 Power Modules User Manual, and H3C LSVM1AC300 & LSVM1DC300 Power Modules User Manual.
Table 5 Installing power modules
Switch model |
Available power modules |
Installation diagram |
S5820X-28S S5820X-28C |
· PSR300-12A · PSR300-12A1 · PSR300-12A2 · PSR300-12D1 · PSR300-12D2 |
See Figure 26. This figure uses the PSR300-12A power module as an example. |
S5820X-26S |
· LSVM1AC650 · LSVM1DC650 · LSVM1AC300 · LSVM1DC300 |
See Figure 27. This figure uses the LSVM1AC650 power module as an example. |
Figure 26 Installing a PSR300-12A power module
Figure 27 Installing an LSVM1AC650 power module
If only one power module is installed, install the filler panel into another power module slot. Figure 28 uses the S5820X-26S switch as an example.
Figure 28 Installing the filler panel on an S5820X-26S switch
Before you remove a power module, remove the power cord from the power module.
To remove an LSVM1AC650 power module:
1. Hold the handle on the power module with one hand, pivot the latch on the power module to the right with your thumb, and pull the power module part way out of the slot.
2. Supporting the power module bottom with one hand, slowly pull the power module out with the other hand.
Figure 29 Removing an LSVM1AC650 power module
Connecting the power cord
|
CAUTION: · Connect the power cord after you install the power module in the switch. · Make sure the power module switch is turned off when you connect the power cord. · Connect the power cord to the switch before you connect it to the power source. |
Table 6 Connecting the power cord
Power module model |
Standard configuration |
Power cord connection procedures |
· PSR300-12A · PSR300-12A1 · PSR300-12A2 |
· AC power cord · Bail latch |
1. Install the bail latch, as shown in Figure 30. 2. Pull the bail latch upwards, as shown in Figure 31. 3. Connect the power cord, and pull the bail latch down to secure the plug to the receptacle, as shown in Figure 32. |
· PSR300-12D1 · PSR300-12D2 |
DC power cord |
Connect the DC power cord, as shown in Figure 33. |
· LSVM1AC650 · LSVM1AC300 |
· AC power cord · Cable tie |
Connect the AC power cord, and use the cable tie to secure the power cord to the handle of the power module, as shown in Figure 34. |
· LSVM1DC650 · LSVM1DC300 |
· DC power cord · Cable tie |
Connect the DC power cord, as shown in Figure 35. |
Figure 30 Installing a bail latch for a PSR300-12A power module
Figure 31 Pulling the bail latch upwards
Figure 32 Connecting an AC power cord
Figure 33 Connecting the DC power cord to a PSR300-12D1 power module
Figure 34 Connecting the AC power cord to an LSVM1AC650/LSVM1AC300 power module
(1) Cable tie |
(2) AC power cord |
(3) Power module handle |
Figure 35 Connecting the DC power cord to an LSVM1DC650/LSVM1DC300 power module
The DC power cord connector for an LSVM1DC650/LSVM1DC300 power module has tabs. To remove the power cord, squeeze the tabs on the power cord connector with your thumb and forefinger and then pull the connector out, as shown in Figure 36.
Figure 36 Removing the DC power cord from an LSVM1DC650/LSVM1DC650 power module
Installing an interface card
|
CAUTION: · When you install or remove an interface card, do not touch the surface-mounted components. · After you remove an interface card, install the filler panel into the slot immediately if no new interface card is installed. |
In addition to built-in ports, the S5820X-28C switch provides two interface card slots and comes with filler panels in the slots.
You can install one or two interface cards as needed. For the interface cards available for the S5820X-28C switch, see H3C S5820X Switch Series Installation Guide. For more information about interface cards, see H3C S5820X & S5800 Series Ethernet Switches Interface Cards User Manual and H3C LSW1XGT2P0 & LSW1XGT4P0 Interface Cards User Manual.
Figure 37 Removing the filler panel from an interface card slot
Figure 38 Installing an interface card
Installing an OAP card
|
CAUTION: · When you install or remove an OAP card, do not touch the surface-mounted components. · After you remove the OAP card, install the filler panel into the slot immediately if no new OAP card is installed. |
The S5820X-28C switch provides an OAP card slot and comes with a filler panel in the OAP card slot.
You can install an OAP card as needed. For the OAP cards available for the S5820X-28C switch, see H3C S5820X Switch Series Installation Guide. For more information about OAP cards, see H3C OAP Cards User Manual.
Figure 39 Removing the filler panel from an OAP card slot
Figure 40 Installing an OAP card