H3C UniServer R4700 G3 Server Ecodesign Manual-6PW103

HomeSupportServersH3C UniServer R4700 G3Install & UpgradeCompliance and Safety InformationH3C UniServer R4700 G3 Server Ecodesign Manual-6PW103
Download Book
  • Released At: 14-11-2023
  • Page Views:
  • Downloads:
Table of Contents
Related Documents

H3C IT RACK Series Product Information for Ecodesign Requirements of (EU) 2019/424

Regulatory Reference: COMMISSION REGULATION (EU) 2019/424, implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for servers and online data storage products.

Product Type

Server

Manufacturer

New H3C Technologies Co., Ltd

Trade

H3C

Address

466 Changhe Road, Binjiang, 310052 Hangzhou, PEOPLE'S REPUBLIC OF CHINA

Product Model

H3C UniServer R4700 G3

Year of Manufacture

2017

PSU Efficiency

PSU model

DPS-550AB-22 G

Rated Output

+12V/45.8A,+12VSB/2.1A

Rated Load

10%

20%

50%

100%

PSU Efficiency

91.72%

94.22%

95.44%

93.90%

Power Factor

-

-

0.996

-

 

PSU model

DPS-850AB-4

Rated Output

+12V/70.8A,+12VSB/2.1A

Rated Load

10%

20%

50%

100%

PSU Efficiency

91.36%

93.52%

94.59%

92.10%

Power Factor

-

-

0.984

-

 

PSU model

DPS-1600AB-13 R

Rated Output

12V/132A,12VSB/2.1A

Rated Load

10%

20%

50%

100%

PSU Efficiency

91.91%

94.03%

94.34%

92.40%

Power Factor

-

-

0.994

-

 

PSU model

PS-2551-9L3

Rated Output

12V/45A,12VSB/2.5A

Rated Load

10%

20%

50%

100%

PSU Efficiency

89.31%

92.83%

94.04%

92.33%

Power Factor

-

-

0.994

-

 

PSU model

PS-2801-9L3

Rated Output

12V/66A,12VSB/2.5A

Rated Load

10%

20%

50%

100%

PSU Efficiency

88.56%

92.38%

94.19%

91.97%

Power Factor

-

-

0.993

-

 

Note1: DC-DC internal power supplies don’t need to fill in the form.

Note2: External Power Supplies (EPS) are regulated as a separate component in the European Union and a separate compliance document is required for EPSs. Leave Internal Power Supply test data fields blank for products that use an EPS (and that do not use an internal power supply).

Idle State Power (W) and Active state efficiency

The test for Idle State power and Active State Efficiency is based on ETSI EN 303 470 V1.1.1 (2019-03)- Environmental Engineering (EE); Energy Efficiency measurement methodology and metrics for servers.

Configuration

Idle State Power (W)

Active state efficiency

Low-end performance configuration

176

15.4

High-end performance configuration

202.3

36.2

Note: SERT Active State Efficiency must be higher to pass to table 5 of the Regulation. SERT Idle State Power must be lower than the calculated limit to pass- described in Annex II 2.1 of the Regulation.

Components List for additional idle power allowances

System characteristics

Quantity

Additional Idle Power Allowances

CPU Performance

2

18.9

Additional PSU

0

0

HDD or SSD

3

15

Additional Memory (GB)

764

137.52

Additional buffered DDR Channel

16

64

Additional I/O devices

0

0

Total additional idle power allowances

/

235.42

Maximum Power (W)

Configuration

Maximum Power

Low-end performance configuration

268.5

High-end performance configuration

273.4

Operating Condition Class      

 

Dry bulb temp °C

Humidity range, non-condensing

 

 

Operating Condition Class

Allowable Range

Recommended Range

Allowable Range

Recommended Range

Max Dew Point (°C)

Maximum rate of Change (°C/hr)

A4

5-45

18-27

-12 °C DP and 8 % RH to 24 °C DP and 90 % RH

-9 °C DP to 15 °C DP and 60 % RH

24

5/20

 

Idle State Power at the higher boundary temperature of the declared operating condition class

Configuration

Idle State Power

Low-end performance configuration

268.5

High-end performance configuration

273.4

Secure data deletion functionality

Instruction on how to use

Copy the script and run it in the OS

Used Techniques

All data covered in the whole disk

Supported standards

DoD 5220.22-M

List of all model configurations    

Computing

2 × Intel® Xeon® Scalable processors (Up to 28 cores and maximum 205 W power consumption)

Memory

3.0 TB (maximum) 24 × DDR4 DIMMs (Up to 2933 MT/s data transfer rate and support for both RDIMM and LRDIMM) (Up to 12 Intel ® Optane™ DC Persistent Memory Module.(DCPMM)

Storage

Front 4LFF + rear 2SFF or front 10SFF + rear 2SFF (supports SAS/SATA HDD/SSD and up to 8 front NVMe drives) 480 GB SATA M.2 SSDs

GPU

2 × single-slot wide GPU modules

Note: The configurations of server product family are end-user configurable / selectable, the detail can be found at http://www.h3c.com

The Concentration of Cobalt and Neodymium

Item

Description

Cobalt in battery

Less than 5g

Neodymium in HDD

between 5 g and 25 g

Disassembly Operations

Operation Type

Description

Data Storage Device

Remove Screw

Memory

Release buckle

CPU

Remove Screw

Motherboard

Remove Screw

Expansion/Graphic Card

Remove Screw

PSU

Release buckle

Chassis

Release buckle

Batteries

Release buckle

Fastening technique type

Quantity

Required Tool

Trox Screw

26

Trox Screw Driver T15

Trox Screw

9

Trox Screw Driver T10

Philps Screw

5

Philps Screw Driver #2

Pan Head Screw

3

Pan Head Screw Driver Medium

Buckle

60

/

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网