03-Appendix B Managed Hot Removal of OCP Network Adapters

Restrictions and guidelines

To view the operating systems that support hot swapping of OCP network adapters, use the OS Compatibility Lookup Tool at http://www.h3c.com/en/home/qr/default.htm?id=66.

Make sure the following software version requirements are met:

·     BIOS: 6.00.15 or later.

·     HDM2: 1.13 or later.

·     CPLD: V004 or later.

Procedure

 

NOTE:

This section uses the OCP network adapter in slot 16 as an example.

 

1.     Access the operating system.

2.     Execute the dmidecode -t 9 command to search for the bus address of the OCP network adapter. As shown in Figure 1, the bus address of the OCP network adapter in slot 16 is 0000:31:00.0.

Figure 1 Searching for the bus address of an OCP network adapter by slot number

 

3.     Execute the echo 0 > /sys/bus/pci/slots/slot_number/power command to power off the network adapter, where slot_number represents the number of the slot where the OCP network adapter resides.

Figure 2 Executing the echo 0 > /sys/bus/pci/slots/slot_number/power command

 

4.     Identify whether the OCP network adapter has been disconnected:

¡     Observe the OCP network adapter LED. If the LED is off, it indicates that the OCP network adapter has been disconnected.

¡     In Figure 3, the bus address is 0000:31:00.0. Execute the lspci –vvv –s 0000:31:00.0 command. If no output is displayed, it indicates that the OCP network adapter has been disconnected.

Figure 3 Identifying OCP network adapter status

 

5.     Reinstall the OCP network adapter.

6.     Execute the echo 1 > /sys/bus/pci/slots/slot_number/power command to power off the network adapter, where slot_number represents the number of the slot where the OCP network adapter resides.

Figure 4 Executing the echo 1 > /sys/bus/pci/slots/slot_number/power command

 

7.     Identify whether the OCP network adapter has been connected:

¡     Observe the OCP network adapter LED. If the LED is on, it indicates that the OCP network adapter has been connected.

¡     In Figure 5, the bus address is 0000:31:00.0. Execute the lspci –vvv –s 0000:31:00.0 command. If the command output is displayed, it indicates that the OCP network adapter has been connected.

Figure 5 Identifying OCP network adapter status

 

8.     Identify whether any exception exists. If any exception occurs, contact Technical Support.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us