- Table of Contents
- Related Documents
-
| Title | Size | Download |
|---|---|---|
| 01-Text | 4.55 MB |
1 Product models and technical specifications
3 FRUs and compatibility matrixes
600W power supply (PSR600-54A-B)
920W power supply (PSR920-54A-B)
1600W power supply (PSR1600-54A-B)
10/100/1000BASE-T Ethernet port
Fan tray status LED on a fan tray
Status LEDs on a 600W/920W/1600W power supply
1 Product models and technical specifications
Product models
This document is applicable to the FS5500V2-EI switch series. Table1-1 describes the FS5500V2-EI switch series models.
Table1-1 FS5500V2-EI switch series models
|
Switch series |
Model |
Product code |
|
FS5500V2-EI switch series |
FS5500V2-24PMS4X-EI-Q |
LS-FS5500V2-24PMS4X-EI-Q |
|
FS5500V2-24UXS6Y-EI |
LS-FS5500V2-24UXS6Y-EI |
|
|
FS5500V2-24UX2C-EI |
LS-FS5500V2-24UX2C-EI |
|
|
FS5500V2-48UXS4Y2Q-EI |
LS-FS5500V2-48UXS4Y2Q-EI |
Technical specifications
Table1-2 Technical specifications
|
Item |
FS5500V2-24PMS4X-EI-Q |
FS5500V2-24UXS6Y-EI |
FS5500V2-24UX2C-EI |
FS5500V2-48UXS4Y2Q-EI |
|
Dimensions (H × W × D) |
43.6 × 440 × 320 mm (1.72 × 17.32 × 12.60 in) |
43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
|
Weight |
≤ 6.5 kg (14.33 lb) |
≤ 7.2 kg (15.87 lb) |
≤ 7.2 kg (15.87 lb) |
≤ 7.5 kg (16.53 lb) |
|
Console port |
1 |
1 |
1 |
1 |
|
USB port |
1 |
1 |
1 |
1 |
|
Management Ethernet port |
1 |
1 |
1 |
1 |
|
10/100/1000BASE-T autosensing Ethernet port |
4 (Each and its corresponding SFP port form a combo interface) |
N/A |
N/A |
N/A |
|
SFP port |
4 (SFP ports 21 to 24 and their corresponding 10/100/1000BASE-T autosensing Ethernet ports form combo interfaces) |
N/A |
N/A |
42 |
|
2.5G SFP port |
20 |
12 |
N/A |
N/A |
|
SFP+ port |
4 |
12 |
24 |
6 |
|
SFP28 port |
N/A |
6 |
N/A |
4 |
|
QSFP+ port |
N/A |
N/A |
N/A |
2 |
|
QSFP28 port |
N/A |
N/A |
2 |
N/A |
|
Power supply slot |
N/A |
2, on the rear panel |
||
|
Fan tray slot |
N/A |
2, on the rear panel |
||
|
Input voltage |
AC input: · Rated voltage range: 100 VAC to 240 VAC @ 50 or 60 Hz · Max voltage range: 90 VAC to 290 VAC@ 47 to 63 Hz |
|||
|
Power consumption (static) |
Single AC: 24 W |
Single AC: 39 W Dual AC: 46 W |
Single AC: 41 W Dual AC: 48 W |
Single AC: 49 W Dual AC: 58 W |
|
Power consumption (with typical configuration) |
Single AC: 27 W |
Single AC: 48 W Dual AC: 55 W |
Single AC: 50 W Dual AC: 57 W |
Single AC: 57 W Dual AC: 64 W |
|
Power consumption (full load) |
Single AC: 478 W |
Depends on the power supply configuration, as shown in Table1-3. |
||
|
PoE power capacity |
370 W |
Depends on the power supply configuration, as shown in Table1-4. |
||
|
Max PoE power capacity per port |
Copper port: 35 W Fiber port: 100 W |
Fiber port: 100 W |
||
|
Chassis leakage current compliance |
UL62368-1/EN62368-1/IEC62368-1/UL60950-1/IEC60950-1/GB4943.1 |
|||
|
Melting current of power supply fuse |
10 A/250 V |
· PSR600-54A-B: 10 A/250 V · PSR920-54A-B: 16 A/250 V · PSR1600-54A-B: 16 A/250 V |
||
|
Operating temperature |
–5°C to +45°C (23°F to 113°F) NOTE: The maximum acceptable temperature decreases by 0.33°C (0.59°F) for every 100 m (328.08 ft) increase in altitude from 0 m (0 ft). |
|||
|
Operating relative humidity |
5% to 95%, noncondensing |
|||
|
Fire resistance compliance |
UL62368-1/EN62368-1/IEC62368-1/UL60950-1/IEC60950-1/GB4943.1 |
|||
Table1-3 Power consumption of the FS5500V2-EI switch series (full load)
|
Power supply configuration |
FS5500V2-24UXS6Y-EI |
FS5500V2-24UX2C-EI |
FS5500V2-48UXS4Y2Q-EI |
|
1 × PSR600-54A-B |
600 W |
589 W |
611 W |
|
1 × PSR920-54A-B |
969 W |
972 W |
999 W |
|
1 × PSR1600-54A-B (90 VAC to 176 VAC) |
960 W |
966 W |
1001 W |
|
1 × PSR1600-54A-B (176 VAC to 290 VAC or 180 VDC to 320 VDC) |
1638 W |
1620 W |
1653 W |
|
2 × PSR600-54A-B |
1245 W |
1270 W |
1263 W |
|
2 × PSR920-54A-B |
1892 W |
1949 W |
1964 W |
|
2 × PSR1600-54A-B (90 VAC to 176 VAC) |
1939 W |
1912 W |
1967 W |
|
2 × PSR1600-54A-B (176 VAC to 290 VAC or 180 VDC to 320 VDC) |
2638 W |
2626 W |
3152 W |
Table1-4 PoE power capacity of the FS5500V2-EI switch series
|
Power supply configuration |
FS5500V2-24UXS6Y-EI |
FS5500V2-24UX2C-EI |
FS5500V2-48UXS4Y2Q-EI |
|||
|
Total PoE power capacity |
Max PoE power capacity per port |
Total PoE power capacity |
Max PoE power capacity per port |
Total PoE power capacity |
Max PoE power capacity per port |
|
|
1 × PSR600-54A-B |
450 W |
100 W |
450 W |
100 W |
450 W |
100 W |
|
1 × PSR920-54A-B |
770 W |
100 W |
770 W |
100 W |
770 W |
100 W |
|
1 × PSR1600-54A-B (90 VAC to 176 VAC) |
770 W |
100 W |
770 W |
100 W |
770 W |
100 W |
|
1 × PSR1600-54A-B (176 VAC to 290 VAC or 180 VDC to 320 VDC) |
1450 W |
100 W |
1450 W |
100 W |
1450 W |
100 W |
|
2 × PSR600-54A-B |
1020 W |
100 W |
1020 W |
100 W |
1020 W |
100 W |
|
1 × PSR600-54A-B and 1 × PSR920-54A-B |
1020 W |
100 W |
1020 W |
100 W |
1020 W |
100 W |
|
2 × PSR920-54A-B |
1600 W |
100 W |
1600 W |
100 W |
1600 W |
100 W |
|
1 × PSR920-54A-B and 1 × PSR1600-54A-B (90 VAC to 176 VAC) |
1260 W |
100 W |
1260 W |
100 W |
1260 W |
100 W |
|
1 × PSR920-54A-B and 1 × PSR1600-54A-B (176 VAC to 290 VAC or 180 VDC to 320 VDC) |
1600 W |
100 W |
1600 W |
100 W |
1600 W |
100 W |
|
2 × PSR1600-54A-B (90 VAC to 176 VAC) |
1600 W |
100 W |
1600 W |
100 W |
1600 W |
100 W |
|
1 × PSR1600-54A-B (90 VAC to 176 VAC) and 1 × PSR1600-54A-B (176 VAC to 290 VAC or 180 VDC to 320 VDC) |
1600 W |
100 W |
1600 W |
100 W |
1600 W |
100 W |
|
2 × PSR1600-54A-B (176 VAC to 290 VAC or 180 VDC to 320 VDC) |
2850 W |
100 W |
2850 W |
100 W |
2850 W |
100 W |
|
IMPORTANT: Do not install a PSR600-54A-B and a PSR1600-54A-B on the same switch. |
2 Chassis views
FS5500V2-24PMS4X-EI-Q
Figure2-1 Front panel
|
(1) 10/100/1000BASE-T autosensing Ethernet port LED |
(2) 10/100/1000BASE-T autosensing Ethernet port |
|
(3) SFP+ port LED |
(4) SFP + port |
|
(5) Management Ethernet port LED (ACT) |
(6) Management Ethernet port (MGMT) |
|
(7) Mode button |
(8) Management Ethernet port LED (LINK) |
|
(9) USB port |
(10) Console port |
|
(11) System status LED (SYS) |
(12) Mode LED (MODE) |
|
(13) SFP port |
(14) SFP port LED |
|
(15) 2.5G SFP port LED |
(16) PoE port |
|
(17) 2.5G SFP port |
|
|
|
NOTE: Each SFP port or 2.5G SFP port and the PoE port under it form a combined photoelectric hybrid port. To provide data transmission and power supply, use combined photoelectric hybrid ports together with transceiver modules, hybrid copper-fiber cables, and combined fiber-copper pigtails. |
Figure2-2 Rear panel
|
(1) Grounding screw |
(2) AC power receptacle |
FS5500V2-24UXS6Y-EI
Figure2-3 Front panel
|
(1) SFP port LED |
(2) SFP+ port LED |
|
(3) SFP28 port LED |
(4) SFP28 port |
|
(5) Management Ethernet port LED (ACT) |
(6) Management Ethernet port LED (LINK) |
|
(7) Management Ethernet port (MGMT) |
(8) USB port |
|
(9) Mode button |
(10) Console port |
|
(11) System status LED (SYS) |
(12) Mode LED (MODE) |
|
(13) Removable power supply 2 status LED (PWR2) |
(14) Removable power supply 1 status LED (PWR1) |
|
(15) SFP + port |
(16) PoE port |
|
(17) SFP port |
|
|
|
NOTE: · Each SFP port or SFP+ port and the PoE port under it form a combined photoelectric hybrid port. To provide data transmission and power supply, use combined photoelectric hybrid ports together with transceiver modules, hybrid copper-fiber cables, and combined fiber-copper pigtails. · Ports 13 through 24 on the switch operate at 2.5 Gbps by default. After you install a license on the switch, these ports can operate at 10 Gbps. |
|
(1) Removable fan tray 1 |
(2) Removable fan tray 2 |
|
(3) Removable power supply 1 |
(4) Removable power supply 2 |
|
(5) Grounding screw |
|
The FS5500V2-24UXS6Y-EI switch came with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-4, two PSR600-54A-B power supplies are installed in the power supply slots.
The FS5500V2-24UXS6Y-EI switch came with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-4, two LSPM1FANSB-SN fan trays are installed in the fan tray slots.
FS5500V2-24UX2C-EI
Figure2-5 Front panel
|
(1) SFP+ port LED |
(2) QSFP28 port LED |
|
(3) Management Ethernet port LED (ACT) |
(4) Management Ethernet port (MGMT) |
|
(5) Mode button |
(6) Management Ethernet port LED (LINK) |
|
(7) USB port |
(8) Console port |
|
(9) System status LED (SYS) |
(10) Mode LED (MODE) |
|
(11) Removable power supply 2 status LED (PWR2) |
(12) Removable power supply 1 status LED (PWR1) |
|
(13) QSFP28 port |
(14) PoE port |
|
(15) SFP+ port |
|
|
|
NOTE: · Each SFP+ port and the PoE port under it form a combined photoelectric hybrid port. To provide data transmission and power supply, use combined photoelectric hybrid ports together with transceiver modules, hybrid copper-fiber cables, and combined fiber-copper pigtails. · Ports 25 and 26 on the switch operate at 40 Gbps by default. After you install a license on the switch, these ports can operate at 100 Gbps. |
|
(1) Removable fan tray 1 |
(2) Removable fan tray 2 |
|
(3) Removable power supply 1 |
(4) Removable power supply 2 |
|
(5) Grounding screw |
|
The FS5500V2-24UX2C-EI switch came with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-6, two PSR600-54A-B power supplies are installed in the power supply slots.
The FS5500V2-24UX2C-EI switch came with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-6, two LSPM1FANSB-SN fan trays are installed in the fan tray slots.
FS5500V2-48UXS4Y2Q-EI
Figure2-7 Front panel
|
(1) SFP port LED |
(2) SFP port |
|
(3) PoE port |
(4) SFP28 port LED |
|
(5) SFP28 port |
(6) QSFP+ port LED |
|
(7) QSFP+ port |
(8) Mode button |
|
(9) USB port |
(10) Console port |
|
(11) System status LED (SYS) |
(12) Mode LED (MODE) |
|
(13) Removable power supply 2 status LED (PWR2) |
(14) Removable power supply 1 status LED (PWR1) |
|
|
NOTE: Each SFP port and the PoE port under it form a combined photoelectric hybrid port. To provide data transmission and power supply, use combined photoelectric hybrid ports together with transceiver modules, hybrid copper-fiber cables, and combined fiber-copper pigtails. |
|
(1) Management Ethernet port LED (ACT) |
(2) Management Ethernet port LED (LINK) |
|
(3) Removable fan tray 1 |
(4) Removable fan tray 2 |
|
(5) Removable power supply 1 |
(6) Removable power supply 2 |
|
(7) Management Ethernet port (MGMT) |
(8) Grounding screw |
The FS5500V2-48UXS4Y2Q-EI switch came with power supply slot PWR1 empty and power supply slot PWR2 installed with a filler panel. You can install one or two power supplies for the switch as required. In Figure2-8, two PSR600-54A-B power supplies are installed in the power supply slots.
The FS5500V2-48UXS4Y2Q-EI switch came with the two fan tray slots empty. You must install two fan trays of the same model for the switch. In Figure2-8, two LSPM1FANSB-SN fan trays are installed in the fan tray slots.
3 FRUs and compatibility matrixes
Removable components
The FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch) supports removable components. Table3-1 describes the removable components available for the switch.
Table3-1 Compatibility matrix between switches and removable components
|
Removable component model |
FS5500V2-24UXS6Y-EI FS5500V2-24UX2C-EI FS5500V2-48UXS4Y2Q-EI |
|
Removable power supplies |
|
|
PSR600-54A-B |
Supported |
|
PSR920-54A-B |
Supported |
|
PSR1600-54A-B |
Supported |
|
Removable fan trays |
|
|
LSPM1FANSB-SN |
Supported |
|
IMPORTANT: Do not install a PSR600-54A-B and a PSR1600-54A-B on the same switch. |
|
|
NOTE: · The power supplies support asset management. You can use the display device manuinfo command to view the name, sequence number, and vendor of the power supplies you have installed on the device. · You can install one power supply, or two power supplies for 1+1 redundancy on the FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch). PoE capabilities vary by power supply configuration. When a power supply fails, PoE capabilities of the switch might decrease. For more information about PoE power capacity, see Table1-3. · The FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch) uses removable fan trays. You can power on the switch only when the switch has two fan trays of the same model installed. |
Removable power supplies
The FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch) uses removable power supplies. Select power supplies as required.
Table3-2 Removable power supplies
|
Power supply model |
Item |
Specification |
Reference |
|
PSR600-54A-B |
Rated input voltage range |
100 VAC to 240 VAC @ 50 Hz or 60 Hz |
H3C PSR600-54A-B Power Module User Manual |
|
Max input voltage range |
90 VAC to 290 VAC @ 47 Hz to 63 Hz |
||
|
Maximum power |
600 W |
||
|
PSR920-54A-B |
Rated input voltage range |
100 VAC to 240 VAC @ 50 Hz or 60 Hz |
H3C PSR920-54A-B Power Module User Manual |
|
Max input voltage range |
90 VAC to 290 VAC @ 47 Hz to 63 Hz |
||
|
Maximum power |
920 W |
||
|
PSR1600-54A-B |
Rated input voltage range |
100 VAC to 240 VAC @ 50 Hz or 60 Hz |
H3C PSR1600-54A-B Power Module User Manual |
|
Max input voltage range |
90 VAC to 290 VAC @ 47 Hz to 63 Hz |
||
|
Maximum power |
1600 W |
Removable fan trays
The FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch) uses removable fan trays. Select fan trays as required.
|
Item |
Specifications |
|
LSPM1FANSB-SN |
|
|
Dimensions (H × W × D) |
40 × 40.6 × 105 mm (1.57 × 1.60 × 4.13 in) |
|
Fan speed |
20000 R.P.M |
|
Max airflow |
20 CFM (0.57 m3/min) |
|
Airflow direction |
Draws air from the port side to the power supply side |
|
Input voltage |
12 V |
|
Power consumption |
9.8 W |
|
Reference |
H3C LSPM1FANSA-SN & LSPM1FANSB-SN Fan Trays User Guide |
|
IMPORTANT: The FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch) uses removable fan trays. You can power on the switch only when the switch has two fan trays of the same model installed. |
4 Removable power supplies
600W power supply (PSR600-54A-B)
View
Figure4-1 PSR600-54A-B AC power supply view
For information about the status LEDs, see "Status LEDs on a 600W/920W/1600W power supply."
Features
PSR600-54A-B is an AC power supply with AC or HVDC input and DC output. Table4-1 describes the features provided by the PSR600-54A-B power supply.
Table4-1 Features provided by the PSR600-54A-B power supply
|
Feature |
Description |
|
Protection function |
Protection against input overcurrent, input undervoltage, output overvoltage, output current limiting, output shortcircuit, and overtemperature conditions. |
|
Support for redundancy |
Two power supplies can be connected in parallel to achieve 1+1 redundancy and load balancing. |
|
Support for hot swapping |
You can remove one of the power supplies in 1+1 redundancy when the switch is operating correctly. |
Technical specifications
Table4-2 Technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) |
40.2 × 73.5 × 213.8 mm (1.58 × 2.89 × 8.42 in), including the handle |
|
Weight |
1 kg (2.20 lb) |
|
Rated AC input voltage range |
AC input: 100 VAC to 240 VAC @ 50 or 60 Hz HVDC input: 240 VDC |
|
Max AC input voltage range |
AC input: 90 VAC to 290 VAC @ 47 to 63 Hz HVDC input: 180 to 320 VDC |
|
Rated input current |
N/A |
|
Rated output current |
11 A |
|
Rated output voltage |
56 V |
|
Rated output power |
600 W |
|
Melting current of power supply fuse |
10 A/250 V |
920W power supply (PSR920-54A-B)
View
Figure4-2 PSR920-54A-B AC power supply view
For information about the status LEDs, see "Status LEDs on a 600W/920W/1600W power supply."
Features
PSR920-54A-B is an AC power supply with AC or HVDC input and DC output. Table4-3 describes the features provided by the PSR920-54A-B power supply.
Table4-3 Features provided by the PSR920-54A-B power supply
|
Feature |
Description |
|
Protection function |
Protection against input overcurrent, input undervoltage, output overvoltage, output current limiting, output shortcircuit, and overtemperature conditions. |
|
Support for redundancy |
Two power supplies can be connected in parallel to achieve 1+1 redundancy and load balancing. |
|
Support for hot swapping |
You can remove one of the power supplies in 1+1 redundancy when the switch is operating correctly. |
Technical specifications
Table4-4 Technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) |
40.2 × 73.5 × 213.8 mm (1.58 × 2.89 × 8.42 in), including the handle |
|
Weight |
1 kg (2.20 lb) |
|
Rated AC input voltage range |
AC input: 100 VAC to 240 VAC @ 50 or 60 Hz HVDC input: 240 VDC |
|
Max AC input voltage range |
AC input: 90 VAC to 290 VAC @ 47 to 63 Hz HVDC input: 180 to 320 VDC |
|
Rated input current |
N/A |
|
Rated output current |
16.5 A |
|
Rated output voltage |
56 V |
|
Rated output power |
920 W |
|
Melting current of power supply fuse |
16 A/250 V |
1600W power supply (PSR1600-54A-B)
View
Figure4-3 PSR1600-54A-B AC power supply view
For information about the status LEDs, see "Status LEDs on a 600W/920W/1600W power supply."
Features
PSR1600-54A-B is an AC power supply with AC or HVDC input and DC output. Table4-5 describes the features provided by the PSR1600-54A-B power supply.
Table4-5 Features provided by the PSR1600-54A-B power supply
|
Feature |
Description |
|
Protection function |
Protection against input overcurrent, input undervoltage, output overvoltage, output current limiting, output shortcircuit, and overtemperature conditions. |
|
Support for redundancy |
Two power supplies can be connected in parallel to achieve 1+1 redundancy and load balancing. |
|
Support for hot swapping |
You can remove one of the power supplies in 1+1 redundancy when the switch is operating correctly. |
Technical specifications
Table4-6 Technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) |
40.2 × 73.5 × 213.8 mm (1.58 × 2.89 × 8.42 in), including the handle |
|
Weight |
1 kg (2.20 lb) |
|
Rated AC input voltage range |
· AC input: 100 VAC to 240 VAC @ 50 or 60 Hz · HVDC input: 240 VDC |
|
Max AC input voltage range |
· AC input: 90 VAC to 290 VAC @ 47 to 63 Hz · HVDC input: 180 to 320 VDC |
|
Rated input current |
N/A |
|
Rated output current |
· AC input: ¡ 17 A: 90 to 176 V @ 47 to 63 Hz ¡ 29 A: 176 to 290 V @ 47 to 63 Hz · HVDC input: 29 A |
|
Rated output voltage |
56 V |
|
Rated output power |
· AC input: ¡ 950 W: 90 to 176 V @ 47 to 63 Hz ¡ 1600 W: 176 to 290 V @ 47 to 63 Hz · HVDC input: 1600 W |
|
Melting current of power supply fuse |
16 A/125 V |
5 Removable fan trays
LSPM1FANSB-SN
View
Figure5-1 LSPM1FANSB-SN fan tray view
For information about the status LED, see "Fan tray status LED on a fan tray."
Features
The LSPM1FANSB-SN fan tray draws air from the port side to the power supply side. The fan tray features small size, fast heat dissipation, and hot swapping. It can automatically adjust the fan speed, providing powerful heat dissipation for the switch.
Technical specifications
Table5-1 Technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) |
40 × 40.6 × 105 mm (1.57 × 1.60 × 4.13 in), including the handles |
|
Fan quantity |
1 |
|
Weight |
N/A |
|
Airflow direction |
Air exhausted from the fan tray faceplate |
|
Fan speed |
20000 R.P.M |
|
Max airflow |
20 CFM (0.57 m3/min) |
|
Input voltage |
12 V |
|
Max power consumption |
9.8 W |
6 Ports and LEDs
Ports
Console port
Table6-1 Console port specifications
|
Item |
Specification |
|
Connector type |
RJ-45 |
|
Compliant standard |
EIA/TIA-232 |
|
Transmission baud rate |
9600 bps (default) to 115200 bps |
|
Services |
· Provides connection to an ASCII terminal · Provides connection to the serial port of a local PC running terminal emulation program |
|
Available switch models |
All switch models |
Management Ethernet port
Table6-2 Management Ethernet port specifications
|
Item |
Specification |
|
Connector type |
RJ-45 |
|
Transmission rate, duplex mode, and auto MDI/MDI-X |
· 10 Mbps, half/full-duplex · 100 Mbps, half/full-duplex · 1000 Mbps, full-duplex · MDI/MDI-X, autosensing |
|
Transmission medium |
Category-5 or above twisted pair cable |
|
Max transmission distance |
100 m (328.08 ft) |
|
Compliant standard |
IEEE 802.3i IEEE 802.3u IEEE 802.3ab |
|
Functions and services |
Connects to a computer or remote network management work station for upgrading and managing applications and Boot ROM |
|
Available switch models |
All switch models |
USB port
Table6-3 USB port specifications
|
Item |
Specification |
|
Connector type |
USB 2.0 |
|
Compliant standard |
OHC |
|
Port transmission rate |
Uploads and downloads data at a rate up to 480 Mbps |
|
Functions and services |
Accesses the file system on the flash of the switch, for example, to upload or download application and configuration files |
|
Available switch models |
All switch models |
|
|
NOTE: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices from other vendors on the switch. If a USB device fails to operate on the switch, replace it with one from another vendor. |
10/100/1000BASE-T Ethernet port
Table6-4 10/100/1000BASE-T Ethernet port specifications
|
Item |
Specification |
|
Connector type |
RJ-45 |
|
Available transceiver modules and cables |
· 10 Mbps, half/full-duplex · 100 Mbps, half/full-duplex · 1000 Mbps, full-duplex · MDI/MDI-X, autosensing |
|
Max transmission distance |
100 m (328.08 ft) |
|
Transmission medium |
Category-5 or above twisted pair cable |
|
Compliant standard |
IEEE 802.3i IEEE 802.3u IEEE 802.3ab |
|
Available switch models |
FS5500V2-24PMS4X-EI-Q |
Combo interface
The FS5500V2-24PMS4X-EI-Q switch provides four fixed combo interfaces on its front panel. Each combo interface contains an SFP port and a 10/100/1000BASE-T autosensing Ethernet port. Only one of these two ports operates at a time.
SFP port
Table6-5 SFP port specifications
|
Item |
Specification |
|
Available transceiver modules and cables |
· See FE SFP transceiver modules described in Table6-6 · See GE SFP transceiver modules and cables described in Table6-7 |
|
Available switch models |
FS5500V2-24PMS4X-EI-Q, FS5500V2-48UXS4Y2Q-EI |
|
Restrictions and guidelines |
· The FS5500V2-24PMS4X-EI-Q switch does not support transceiver modules with a maximum transmission distance of 40 km (24.86 miles) or 80 km (49.71 miles). · The FS5500V2-48UXS4Y2Q-EI switch supports a maximum of 20 SFP-GE-T and SFP-GE-T-D transceiver modules. |
Table6-6 FE SFP transceiver modules available for the SFP ports
|
FE SFP transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Max transmission distance |
|
SFP-FE-SX-MM1310-A |
1310 |
LC |
Multi-mode, 50/125 |
2 km (1.24 miles) |
|
Multi-mode, 62.5/125 |
||||
|
SFP-FE-LX-SM1310-A |
1310 |
LC |
Single-mode, 9/125 |
15 km (9.32 miles) |
|
SFP-FE-LH40-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
40 km (24.86 miles) |
|
SFP-FE-LH80-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
80 km (49.71 miles) |
|
SFP-FE-LX-SM1310-BIDI |
TX: 1310 RX: 1550 |
LC |
Single-mode, 9/125 |
15 km (9.32 miles) |
|
SFP-FE-LX-SM1550-BIDI |
TX: 1550 RX: 1310 |
LC |
Single-mode, 9/125 |
15 km (9.32 miles) |
|
SFP-FE-BX15-U-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
15 km (9.32 miles) |
|
IMPORTANT: The SFP-FE-LX-SM1310-BIDI and SFP-FE-LX-SM1550-BIDI transceiver modules must be used in pairs. For example, if one end uses the SFP-FE-LX-SM1310-BIDI transceiver module, the other end must use the SFP-FE-LX-SM1550-BIDI transceiver module. |
Table6-7 GE SFP transceiver modules and cables
|
GE SFP transceiver module/cable |
Central wavelength (nm) |
Connector |
Cable/Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Max. transmission distance |
|
SFP transceiver module |
|||||
|
SFP-GE-T |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
|
SFP-GE-T-D |
N/A |
RJ-45 |
Twisted pair cable |
N/A |
100 m (328.08 ft) |
|
SFP-GE-LX-SM1310-F |
1310 |
LC |
Single-mode |
N/A |
10 km (6.21 miles) |
|
SFP-GE-SX-MM850-A |
850 |
LC |
Multi-mode, 50/125 |
500 |
550 m (1804.46 ft) |
|
400 |
500 m (1640.42 ft) |
||||
|
Multi-mode, 62.5/125 |
200 |
275 m (902.23 ft) |
|||
|
160 |
200 m (656.17 ft) |
||||
|
SFP-GE-LX-SM1310-A |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
Multi-mode, 50/125 |
500/400 |
550 m (1804.46 ft) |
|||
|
Multi-mode, 62.5/125 |
500 |
550 m (1804.46 ft) |
|||
|
SFP-GE-LH40-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-GE-LH40-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-GE-LH40-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-GE-LH80-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
|
SFP-GE-LH80-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
|
SFP-GE-LH100-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
100 km (62.14 miles) |
|
SFP-GE-LX-SM1310-BIDI |
TX: 1310 RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-GE-LX-SM1490-BIDI |
TX: 1490 RX: 1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-GE-LH40-SM1310-BIDI |
TX: 1310 RX: 1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-GE-LH40-SM1550-BIDI |
TX: 1550 RX: 1310 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-GE-LH70-SM1490-BIDI |
TX: 1490 RX: 1550 |
LC |
Single-mode, 9/125 |
N/A |
70 km (43.50 miles) |
|
SFP-GE-LH70-SM1550-BIDI |
TX: 1550 RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
70 km (43.50 miles) |
|
SFP cable |
|||||
|
SFP-STACK-Kit |
N/A |
N/A |
SFP cable |
N/A |
1.5 m (4.92 ft) |
|
IMPORTANT: The SFP-GE-LX-SM1310-BIDI and SFP-GE-LX-SM1490-BIDI transceiver modules, the SFP-GE-LH40-SM1310-BIDI and SFP-GE-LH40-SM1550-BIDI transceiver modules, and the SFP-GE-LH70-SM1490-BIDI and SFP-GE-LH70-SM1550-BIDI transceiver modules must be used in pairs. For example, if one end uses an SFP-GE-LX-SM1310-BIDI transceiver module, the other end must use an SFP-GE-LX-SM1490-BIDI transceiver module. |
|
|
NOTE: · As a best practice, use H3C transceiver modules and cables for the switch. · The H3C transceiver modules and cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact your H3C Support or marketing staff. · For more information about H3C transceiver modules and cables, see H3C Transceiver Modules User Guide. |
2.5G SFP port
Table6-8 2.5G SFP port specifications
|
Item |
Specification |
|
Available transceiver modules and cables |
· See GE SFP transceiver modules and cables described in Table6-7 · See 2.5G SFP transceiver modules described in Table6-9 |
|
Available switch models |
FS5500V2-24PMS4X-EI-Q, FS5500V2-24UXS6Y-EI |
Table6-9 2.5G SFP transceiver module
|
2.5G SFP transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Max. transmission distance |
|
SFP-2.5G-LX10-SM1310-DR-I-F |
1310 |
PoDLC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-2.5G-LX10-SM1310-DR-I |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-2.5G-LX03-SM1310-BIDI |
· TX: 1310 · RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
3 km (1.86 miles) |
|
SFP-2.5G-LX03-SM1490-BIDI |
· TX: 1490 · RX: 1310 |
LC |
Single-mode, 9/125 |
N/A |
3 km (1.86 miles) |
SFP+ port
Table6-10 SPF+ port specifications
|
Item |
Specification |
|
Available transceiver modules and cables |
· See GE SFP transceiver modules and cables described in Table6-7 · See 2.5G SFP transceiver modules described in Table6-9 · See 10-GE SFP+ transceiver modules and cables described in Table6-11 and Table6-12 |
|
Available switch models |
All switch models |
|
Usage guidelines and restrictions |
Ports 13 through 24 on the FS5500V2-24UXS6Y-EI switch operate at 2.5 Gbps by default. After you install a license on the switch, these ports can operate at 10 Gbps. |
Table6-11 10-GE SFP+ transceiver modules
|
10-GE SFP+ transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Max. transmission distance |
|
SFP-XG-SX-MM850-D |
850 |
LC |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
|
500 |
82 m (269.03 ft) |
||||
|
400 |
66 m (216.54 ft) |
||||
|
Multi-mode, 62.5/125 |
200 |
33 m (108.27 ft) |
|||
|
160 |
26 m (85.30 ft) |
||||
|
SFP-XG-LX-SM1310-D |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-XG-LX-SM1310-F |
1310 |
LC |
Single-mode |
N/A |
10 km (6.21 miles) |
|
SFP-XG-LH40-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-XG-LH40-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-XG-LH80-SM1550 |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
|
SFP-XG-LH80-SM1550-D |
1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
|
SFP-XG-LX-SM1270-BIDI |
TX: 1270 RX: 1330 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-XG-LX-SM1330-BIDI |
TX: 1330 RX: 1270 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
SFP-XG-LH40-SM1270-BIDI |
TX: 1270 RX: 1330 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-XG-LH40-SM1330-BIDI |
TX: 1330 RX: 1270 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
SFP-XG-LH80-SM1490-BIDI |
TX: 1490 RX: 1550 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
|
SFP-XG-LH80-SM1550-BIDI |
TX: 1550 RX: 1490 |
LC |
Single-mode, 9/125 |
N/A |
80 km (49.71 miles) |
|
IMPORTANT: The SFP-XG-LX-SM1270-BIDI and SFP-XG-LX-SM1330-BIDI transceiver modules, SFP-XG-LH40-SM1270-BIDI and SFP-XG-LH40-SM1330-BIDI transceiver modules, and SFP-XG-LH80-SM1490-BIDI and SFP-XG-LH80-SM1550-BIDI transceiver modules must be used in pairs. For example, if one end uses an SFP-XG-LX-SM1270-BIDI transceiver module, the other end must use an SFP-XG-LX-SM1330-BIDI transceiver module. |
Table6-12 10-GE SFP+ copper and fiber cables available for the SFP+ ports
|
Item |
Cable length |
|
SFP+ copper cable |
|
|
LSWM1STK |
0.65 m (2.13 ft) |
|
LSWM2STK |
1.2 m (3.94 ft) |
|
LSWM3STK |
3 m (9.84 ft) |
|
LSTM1STK |
5 m (16.40 ft) |
|
SFP+ fiber cable |
|
|
SFP-XG-D-AOC-7M |
7 m (22.97 ft) |
|
SFP-XG-D-AOC-10M |
10 m (32.81 ft) |
|
SFP-XG-D-AOC-20M |
20 m (65.62 ft) |
|
|
NOTE: · As a best practice, use H3C transceiver modules and cables for the switch. · The H3C transceiver modules and cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact your H3C Support or marketing staff. · For more information about H3C transceiver modules and cables, see H3C Transceiver Modules User Guide. |
|
(1) Connector |
(2) Pull latch |
SFP28 port
Table6-13 SFP28 port specifications
|
Item |
Specification |
|
Available transceiver modules and cables |
· See 10-GE SFP+ transceiver modules and cables described in Table6-11 and Table6-12 · See 25-GE SFP28 transceiver modules and cables described in Table6-14 and Table6-15 |
|
Available switch models |
FS5500V2-24UXS6Y-EI, FS5500V2-48UXS4Y2Q-EI |
Table6-14 25-GE SFP28 transceiver modules available for the SFP28 ports
|
25-GE SFP28 transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz*km) |
Maximum transmission distance |
|
SFP-25G-SR-MM850 |
850 |
LC |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
|
4700 |
100 m (328.08 ft) |
||||
|
SFP-25G-LR-SM1310 |
1310 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
Table6-15 25G SFP28 copper and fiber cables available for the SFP28 ports
|
Item |
Cable length |
|
25G SFP28 copper cable |
|
|
SFP-25G-D-CAB-1M |
1 m (3.28 ft) |
|
SFP-25G-D-CAB-3M |
3 m (9.84 ft) |
|
SFP-25G-D-CAB-5M |
5 m (16.40 ft) |
|
25G SFP28 fiber cable |
|
|
SFP-25G-D-AOC-3M |
3 m (9.84 ft) |
|
SFP-25G-D-AOC-5M |
5 m (16.40 ft) |
|
SFP-25G-D-AOC-7M |
7 m (22.97 ft) |
|
SFP-25G-D-AOC-10M |
10 m (32.81 ft) |
|
SFP-25G-D-AOC-20M |
20 m (65.62 ft) |
|
|
NOTE: · As a best practice, use H3C transceiver modules and cables for the switch. · The H3C transceiver modules and cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact your H3C Support or marketing staff. · For more information about H3C transceiver modules and cables, see H3C Transceiver Modules User Guide. |
|
(1) Connector |
(2) Pull latch |
QSFP+ port
Table6-16 QSPF+ port specifications
|
Item |
Specification |
|
Available transceiver modules and cables |
See QSFP+ transceiver modules and cables described in Table6-17 and Table6-18 |
|
Available switch models |
FS5500V2-48UXS4Y2Q-EI |
Table6-17 QSFP+ transceiver modules available for the QSFP+ ports
|
QSFP+ transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
|
QSFP-40G-SR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
100 m (328.08 ft) |
|
4700 |
150 m (492.13 ft) |
||||
|
QSFP-40G-CSR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
300 m (984.25 ft) |
|
4700 |
400 m (1312.34 ft) |
||||
|
QSFP-40G-LR4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
QSFP-40G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 50/125 |
N/A |
2 km (1.24 miles) |
|
QSFP-40G-BIDI-SR-MM850 |
850 |
LC |
Multi-mode, 50/125 |
2000 |
100 m (328.08 ft) |
|
4700 |
150 m (492.13 ft) |
||||
|
QSFP-40G-BIDI-WDM850 |
Four lanes: · 850 · 880 · 910 · 940 |
LC |
Multi-mode, 50/125 |
2000 |
240 m (787.40 ft) |
|
4700 |
350 m (1148.29 ft) |
||||
|
QSFP-40G-ER4-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 50/125 |
N/A |
40 km (24.86 miles) |
Table6-18 40G QSFP+ copper and fiber cables available for the QSFP+ ports
|
Item |
Cable length |
|
QSFP+ copper cable |
|
|
LSWM1QSTK0 |
1 m (3.28 ft) |
|
LSWM1QSTK1 |
3 m (9.84 ft) |
|
LSWM1QSTK2 |
5 m (16.40 ft) |
|
QSFP+ fiber cable |
|
|
QSFP-40G-D-AOC-3M |
3 m (9.84 ft) |
|
QSFP-40G-D-AOC-7M |
7 m (22.97 ft) |
|
QSFP-40G-D-AOC-10M |
10 m (32.81 ft) |
|
QSFP-40G-D-AOC-20M |
20 m (65.62 ft) |
|
|
NOTE: · As a best practice, use H3C transceiver modules and cables for the switch. · The H3C transceiver modules and cables are subject to change over time. For the most recent list of H3C transceiver modules and cables, contact your H3C Support or marketing staff. · For more information about H3C transceiver modules and cables, see H3C Transceiver Modules User Guide. |
|
(1) Connector |
(2) Pull latch |
QSFP28 port
Table6-19 QSFP28 port specifications
|
Item |
Specification |
|
Available transceiver modules and cables |
· See QSFP+ transceiver modules and cables described in Table6-17 and Table6-18 · See QSFP28 transceiver modules and cables described in Table6-20 and Table6-21 |
|
Available switch models |
FS5500V2-24UX2C-EI |
|
Usage guidelines and restrictions |
QSFP28 ports on an FS5500V2-24UX2C-EI switch operate at 40 Gbps by default. After you install a license on the switch, the QSFP28 ports can operate at 100 Gbps. |
Table6-20 QSFP28 transceiver modules available for the QSFP28 ports
|
QSFP28 transceiver module |
Central wavelength (nm) |
Connector |
Fiber type and diameter (µm) |
Modal bandwidth (MHz × km) |
Max transmission distance |
|
QSFP-100G-SR4-MM850 |
850 |
MPO |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
|
4700 |
100 m (328.08 ft) |
||||
|
QSFP-100G-LR4-WDM1300 |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
LC |
Single-mode, 9/125 |
N/A |
10 km (6.21 miles) |
|
QSFP-100G-LR4L-WDM1300 |
Four lanes: · 1271 · 1291 · 1311 · 1331 |
LC |
Single-mode, 9/125 |
N/A |
2 km (1.24 miles) |
|
QSFP-100G-ER4L-WDM1300 |
Four lanes: · 1295.56 · 1300.05 · 1304.58 · 1309.14 |
LC |
Single-mode, 9/125 |
N/A |
40 km (24.86 miles) |
|
QSFP-100G-BIDI-MM850 |
Two lanes: · 855 · 908 |
MPO |
Multi-mode, 50/125 |
2000 |
70 m (229.66 ft) |
|
4700 |
100 m (328.08 ft) |
Table6-21 100G QSFP28 fiber and copper cables available for the QSFP28 ports
|
Item |
Cable length |
|
QSFP28 fiber cable |
|
|
QSFP-100G-D-AOC-7M |
7 m (22.97 ft) |
|
QSFP-100G-D-AOC-10M |
10 m (32.81 ft) |
|
QSFP-100G-D-AOC-20M |
20 m (65.62 ft) |
|
QSFP28 copper cable |
|
|
QSFP-100G-D-CAB-1M |
1 m (3.28 ft) |
|
QSFP-100G-D-CAB-3M |
3 m (9.84 ft) |
|
QSFP-100G-D-CAB-5M |
5 m (16.40 ft) |
LEDs
System status LED
The system status LED shows the operating status of the switch.
Table6-22 System status LED description
|
LED mark |
Status |
Description |
|
SYS |
Steady green |
The switch has started correctly. |
|
Flashing green (1 Hz) |
The switch is performing power-on self test (POST). |
|
|
Steady red |
The switch has failed POST or is faulty. |
|
|
Off |
The switch is powered off. |
Power supply status LED
For switch models that support removable power supplies, the PWR1 and PWR2 LEDs on the front panel indicate the operating status of the power supplies
Table6-23 Power supply status LED description
|
LED mark |
Status |
Description |
|
PWR1/PWR2 |
Steady green |
A power supply is installed in the power supply slot, and the power supply is outputting power correctly. |
|
Steady yellow |
A power supply is installed in the power supply slot, but the power supply is faulty or not powered on. |
|
|
Off |
No power supply is installed in the power supply slot. |
Mode LED (MODE)
The mode LED works in conjunction with the port LEDs to indicate the operating state of the ports and the switch.
· The mode LED indicates the type of information that the port LEDs are showing.
· You can use the mode button to change the indication of the mode LED. After you press the mode button for the mode LED to steady yellow, flashing green, or flashing yellow, the mode LED keeps that state for only 45 seconds and then turns steady green automatically.
Table6-24 Mode LED description
|
LED mark |
Status |
Description |
|
MODE |
Steady green |
The port LEDs are showing link state of the ports. |
|
Flashing green |
The port LEDs are showing the PoE status of the ports. |
|
|
Flashing yellow |
The port LEDs work in conjunction to indicate the IRF member ID of the switch. For example, if the LED for port 4 is steady green, the IRF member ID of the switch is 4. |
SFP port LED
Table6-25 SFP port LED description
|
Mode LED status |
SFP port LED status |
Description |
|
Steady green (rate mode) |
Steady green |
A link is present on the port and the port is operating at 1000 Mbps. |
|
Flashing green |
The port is sending or receiving data at 1000 Mbps. |
|
|
Steady yellow |
A link is present on the port and the port is operating at 100 Mbps. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
Flashing green (PoE mode) |
Steady green |
PoE power supply is normal. |
|
Flashing green |
· The maximum PoE power provided by the port fails to meet the power requirement of the PD. · The remaining power of the switch fails to meet the power supply requirement of the port. |
|
|
Steady yellow |
The port has failed to supply power. |
|
|
Off |
The port is not supplying power through PoE. |
|
|
Flashing yellow (IRF mode) |
Steady green |
The SFP port LEDs work in conjunction to indicate the IRF member ID of the switch. For example, if the LED for port 4 is steady green, the IRF member ID of the switch is 4. |
2.5G SFP port LED
Table6-26 2.5G SFP port LED description
|
Mode LED status |
2.5G SFP port LED status |
Description |
|
Steady green (rate mode) |
Steady green |
A link is present on the port and the port is operating at 2.5 Gbps. |
|
Flashing green |
The port is sending or receiving data at 2.5 Gbps. |
|
|
Steady yellow |
A link is present on the port and the port is operating at 1 Gbps. |
|
|
Flashing yellow |
The port is sending or receiving data at 1 Gbps. |
|
|
Off |
No link is present on the port. |
|
|
Flashing green (PoE mode) |
Steady green |
PoE power supply is normal. |
|
Flashing green |
· The maximum PoE power provided by the port fails to meet the power requirement of the PD. · The remaining power of the switch fails to meet the power supply requirement of the port. |
|
|
Steady yellow |
The port has failed to supply power. |
|
|
Off |
The port is not supplying power through PoE. |
|
|
Flashing yellow (IRF mode) |
Steady green |
The 2.5G SFP port LEDs work in conjunction to indicate the IRF member ID of the switch. For example, if the LED for port 4 is steady green, the IRF member ID of the switch is 4. |
SFP+ port LED
Table6-27 SFP+ port LED description
|
Mode LED status |
SFP+ port LED status |
Description |
|
Steady green (rate mode) |
Steady green |
A link is present on the port and the port is operating at 10 Gbps. |
|
Flashing green |
The port is sending or receiving data at 10 Gbps. |
|
|
Steady yellow |
A link is present on the port and the port is operating at 2.5 Gbps or 1 Gbps. |
|
|
Flashing yellow |
The port is sending or receiving data at 2.5 Gbps or 1 Gbps. |
|
|
Off |
No link is present on the port. |
|
|
Flashing green (PoE mode) |
Steady green |
PoE power supply is normal. |
|
Flashing green |
· The maximum PoE power provided by the port fails to meet the power requirement of the PD. · The remaining power of the switch fails to meet the power supply requirement of the port. |
|
|
Steady yellow |
The port has failed to supply power. |
|
|
Off |
The port is not supplying power through PoE. |
|
|
Flashing yellow (IRF mode) |
Off |
The mode LED is operating in IRF mode. |
SFP28 port LED
Table6-28 SFP28 port LED description
|
SFP28 port LED status |
Description |
|
Steady green |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 25 Gbps. |
|
Flashing green |
The port is sending or receiving data at 25 Gbps. |
|
Steady yellow |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 10 Gbps. |
|
Flashing yellow (3 Hz) |
The port is sending or receiving data at 10 Gbps. |
|
Off |
No transceiver module or cable is installed in the port or no link is present on the port. |
QSFP+ port LED
Table6-29 SFP28 port LED description
|
Description |
|
|
Steady green |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 40 Gbps. |
|
Flashing green |
The port is sending or receiving data at 40 Gbps. |
|
Off |
· No transceiver module or cable is installed in the port or no link is present on the port. · The mode LED is operating in IRF mode. · The mode LED is operating in PoE mode. |
QSFP28 port LED
Table6-30 QSFP28 port LED description
|
QSFP28 port LED status |
Description |
|
Steady green |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 100 Gbps. |
|
Flashing green |
The port is sending or receiving data at 100 Gbps. |
|
Steady yellow |
A transceiver module or cable has been correctly installed. The port has a link and is operating at 40 Gbps. |
|
Flashing yellow |
The port is sending or receiving data at 40 Gbps. |
|
Off |
· No transceiver module or cable is installed in the port or no link is present on the port. · The mode LED is operating in IRF mode. · The mode LED is operating in PoE mode. |
Fan tray status LED on a fan tray
Table6-31 Fan tray status LED description
|
Status |
Description |
|
On |
The fan tray is faulty. |
|
Off |
The fan tray is operating correctly. |
Status LEDs on a 600W/920W/1600W power supply
The PSR600-54A-B, PSR920-54A-B, and PSR1600-54A-B power supplies each have two status LEDs to indicate the power input and output status.
Table6-32 Description for the status LEDs on a 600W/920W/1600W power supply
|
LED |
Mark |
Status |
Description |
|
Output status LED |
OUT OK |
Steady green |
Normal power output. |
|
Steady red |
Abnormal power output. |
||
|
Off |
No power output |
||
|
Input status LED |
IN OK |
Steady green |
Normal power input. |
|
Steady red |
Abnormal power input. |
||
|
Off |
No power input. |
7 Cooling system
To dissipate heat timely and enhance system stability, the switch uses a high-performance cooling system. Consider the site ventilation design when you plan the installation site for the switch.
The FS5500V2-EI switch series (excluding the FS5500V2-24PMS4X-EI-Q switch) uses removable fan trays. For adequate heat dissipation, install two fan trays of the same model for the switch.
|
Switch model |
Available fan tray |
Airflow direction |
|
FS5500V2-24PMS4X-EI-Q |
N/A |
Passive cooling |
|
FS5500V2-24UXS6Y-EI FS5500V2-24UX2C-EI FS5500V2-48UXS4Y2Q-EI |
LSPM1FANSB-SN |
From the port side to the power supply side |
Figure7-1 Airflow through the FS5500V2-48UXS4Y2Q-EI chassis