- Table of Contents
- Related Documents
-
| Title | Size | Download |
|---|---|---|
| 01-Hardware Information and Specifications | 2.13 MB |
1 Product models and technical specifications
2000W AC power supply (PSR2000-12A-C-A/PSR2000-12A-C-B)
2000W AC power supply (PSR2000-12A-S/PSR2000-12A-S-B)
2700W AC power supply (PSR2700-12A-A)
1 Product models and technical specifications
Product models
The H3C S9827 series contains models listed in the following table:
|
Product model |
Product code |
|
S9827-128DH |
LS-9827-128DH |
|
S9827-64E |
LS-9827-64E |
|
S9827-64EP |
LS-9827-64EP |
|
|
NOTE: · To obtain the purchase information, see the product data sheet at https://www.h3c.com/en/Products_and_Solutions/InterConnect/Switches/ and pay attention to the switch product lifecycle management announcement at https://www.h3c.com/en/Support/Policy_Dynamics/Management_Strategy/Products_End_of_Life_Announcement/Switches/. · For information about product and software compatibility, see the release notes. |
Technical specifications
Table1-1 Technical specifications
|
Item |
LS-9827-128DH |
LS-9827-64E |
LS-9827-64EP |
|
Physical specifications |
|||
|
Dimensions (H × W × D) |
175 × 442 × 760 mm (6.89 × 17.40 × 29.92 in) |
88.1 × 440 × 760 mm (3.47 × 17.32 × 29.92 in) |
175 × 442 × 760 mm (6.89 × 17.40 × 29.92 in) |
|
Dimensions (H × W × D, with package materials) |
391 × 655 × 1092 mm (15.39 × 25.79 × 42.99 in) |
225 × 570 × 1115 mm (8.86 × 22.44 × 43.90 in) |
361 × 635 × 1072 mm (14.21 × 25.00 × 42.20 in) |
|
Weight (fully configured with fan modules, power supplies, and supervisor engine modules) |
≤ 41 kg (90.39 lb) |
≤ 30 kg (66.14 lb) |
≤ 45 kg (99.21 lb) |
|
Technical specifications |
|||
|
Processor |
4 cores, 2.6 GHz |
||
|
DRAM memory |
16 GB |
||
|
NOR flash |
2 × 256 MB (primary and backup) |
||
|
NAND flash |
64 GB eMMC flash |
||
|
Port types and quantity |
|||
|
Console port |
1 × serial console port |
||
|
Management Ethernet port |
1 × copper management Ethernet port |
1 × copper management Ethernet port |
1 × copper management Ethernet port |
|
USB port |
1 × USB2.0 port |
||
|
QSFP112 port |
128 |
N/A |
N/A |
|
OSFP800 port |
N/A |
N/A |
64 |
|
QSFP-DD800 port |
N/A |
64 |
N/A |
|
SFP+ port |
N/A |
2 |
N/A |
|
Fan modules, power supplies, and supervisor engine modules (SEMs) |
|||
|
Fan module slot |
8 |
4 |
8 |
|
Power supply slot |
4 |
2 |
4 |
|
SEM slot |
1 |
N/A |
1 |
|
Power supply specifications |
|||
|
Power input |
AC input and DC input |
AC input and DC input |
AC input and DC input |
|
Power consumption |
|||
|
Typical power consumption (Fully configured with copper cables, at 50% load) |
850 W |
729 W |
743 W |
|
Maximum power consumption (Fully configured with transceiver modules, at 100% load) |
3130 W |
3027 W |
3254 W |
|
Thermal consumption |
|||
|
Typical thermal consumption |
Single AC input/dual AC inputs: 498 BTU/hr |
2487 BTU/hr |
2535 BTU/hr |
|
Maximum thermal consumption |
1464 BTU/hr |
6889 BTU/hr |
7664 BTU/hr |
|
Heat dissipation |
|||
|
Heat dissipation method |
Air cooling |
||
|
Ventilation aisles |
Front-to-rear |
||
|
Reliability and availability |
|||
|
Power supply redundancy |
2+2 redundancy |
1+1 redundancy |
2+2 redundancy |
|
Fan module redundancy |
7+1 redundancy |
3+1 redundancy |
7+1 redundancy |
|
Hot swapping |
Supported |
Supported |
Supported |
|
Mean time between failure (MTBF) (year) |
> 50 |
||
|
Mean time to repair (MTTR) (hour) |
< 1 |
||
|
Availability |
99.999927% |
||
|
Environment specifications |
|||
|
Altitude |
0 to 5000 m (0 to 16404.20 ft) |
||
|
Operating temperature |
0°C to 40°C (32°F to 104°F) Note: The allowed maximum temperature decreases by 0.33 °C (32.59°F) as the altitude increases by 100 m (328.08 ft) from 0 m (0 ft). |
||
|
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
||
|
Humidity |
5% RH to 95% RH, noncondensing |
||
|
Compliance |
|||
|
Product compliance |
· Safety standards · EMC standards · Environmental and eco-friendly standards |
||
2 Chassis views
LS-9827-128DH
|
(1) QSFP112 Ethernet fiber port |
(2) QSFP112 port LED |
|
(3) Power status LED (PSU) |
(4) Reset button (RESET) |
|
(5) Location LED (ID) |
(6) Fan module status LED (FAN) |
|
(7) System status LED (SYS) |
(8) USB port |
|
(9) Serial console port |
(10) Copper management Ethernet port (LINK/ACT) |
|
(1) Fan module 1 |
(2) Fan module 2 |
|
(3) Fan module 3 |
(4) Fan module 4 |
|
(5) Power supply 1 |
(6) Power supply 2 |
|
(7) Power supply 3 |
(8) Power supply 4 |
|
(9) Fan module 5 |
(10) Fan module 6 |
|
(11) Fan module 7 |
(12) Power supply 8 |
|
(13) Grounding screw 2 |
(14) Grounding screw 1 |
The switch has four power supply slots at the rear panel and comes with a power supply installed in each power supply slot. You can install two to four power supplies for the switch as needed. In Figure2-2, PSR2000-12A-C-A AC power supplies are installed in the four power supply slots.
The switch comes with eight fan module slots empty. You must install eight fan modules of the same model for the switch. In Figure2-2, FAN-80B-1-C fan modules are installed in the eight fan module slots.
The switch supports shipping with fan modules and power supplies installed. To purchase a switch preinstalled with fan modules and power supplies, contact marketing staff.
Figure2-3 Left view
|
(1) Power supply latch |
(2) Mounting bracket installation position at the port side |
|
(3) Fan module handle |
|
LS-9827-64E
Figure2-4 Front panel
|
(1) System status LED (SYS) |
(2) Location LED (ID) |
|
(3) QSFP-DD800 Ethernet fiber port |
(4) QSFP-DD800 port LED |
|
(5) Reset button (RESET) |
(6) USB port |
|
(7) SFP+ port LED |
(8) SFP+ Ethernet fiber port |
|
(9) Power status LED (PSU) |
(10) Fan module status LED (FAN) |
|
(11) Copper management Ethernet port (LINK/ACT) |
(12) Serial console port |
|
(1) Fan module 1 |
(2) Fan module 2 |
|
(3) Fan module 3 |
(4) Fan module 4 |
|
(5) Power supply 1 |
(6) Power supply 2 |
|
(7) Grounding screw 2 |
(8) Grounding screw 1 |
The switch has two power supply slots at the rear panel and comes with a power supply installed in each power supply slot. In Figure2-5, PSR2700-12A-A AC power supplies are installed in the two power supply slots.
The switch comes with four fan module slots empty. You must install four fan modules of the same model for the switch. In Figure2-5, FAN-80B-1-D fan modules are installed in the four fan module slots.
The switch supports shipping with fan modules and power supplies installed. To purchase a switch preinstalled with fan modules and power supplies, contact marketing staff.
Figure2-6 Left view
|
(1) Power supply latch |
(2) Fan module handle |
|
(3) Mounting bracket installation position at the port side |
|
LS-9827-64EP
Figure2-7 Front panel
|
(1) OSFP800 Ethernet fiber port |
(2) OSFP800 port LED |
|
(3) System status LED (SYS) |
(4) Location LED (ID) |
|
(5) Fan module status LED (FAN) |
(6) Reset button (RESET) |
|
(7) Power status LED (PSU) |
(8) USB port |
|
(9) Serial console port |
(10) Copper management Ethernet port (LINK/ACT) |
|
(1) Fan module 1 |
(2) Fan module 3 |
|
(3) Fan module 5 |
(4) Fan module 7 |
|
(5) Power supply 1 |
(6) Power supply 2 |
|
(7) Power supply 3 |
(8) Power supply 4 |
|
(9) Fan module 8 |
(10) Fan module 6 |
|
(11) Fan module 4 |
(12) Power supply 2 |
|
(13) Grounding screw 2 |
(14) Grounding screw 1 |
The switch has four power supply slots at the rear panel and comes with a power supply installed in each power supply slot. You can install two to four power supplies for the switch as needed. In Figure2-8, PSR2000-12A-S AC power supplies are installed in the four power supply slots.
The switch comes with eight fan module slots empty. You must install eight fan modules of the same model for the switch. In Figure2-8, FAN-80B-1-D fan modules are installed in the eight fan module slots.
The switch supports shipping with fan modules and power supplies installed. To purchase a switch preinstalled with fan modules and power supplies, contact marketing staff.
Figure2-9 Left view
|
(1) Power supply latch |
(2) Fan module handle |
|
(3) Mounting bracket installation position at the port side |
|
3 FRUs
The switch uses modular design. Table3-1 describes the FRUs available for the switch.
Table3-1 FRUs available for the switch
|
FRUs |
Product code |
LS-9827-128DH |
LS-9827-64E |
LS-9827-64EP |
|
Power supplies |
||||
|
PSR2000-12A-C-A |
9803A0D9 9803A0DA |
Yes |
No |
No |
|
PSR2000-12A-C-B |
9803A1PF 9803A1PG |
Yes |
No |
No |
|
PSR2000-12A-S |
0231AMP0 0231AMP2 |
No |
No |
Yes |
|
PSR2000-12A-S-B |
0231AMNU 0231AMNW |
No |
No |
Yes |
|
PSR2700-12A-A |
0231ANGS 0231ANGT |
No |
Yes |
No |
|
Fan modules |
||||
|
FAN-80B-1-C |
9803A0DB 9803A0DC |
Yes |
No |
No |
|
FAN-80B-1-D |
0231AMNR 0231AMNP |
No |
Yes |
Yes |
|
SEMs |
||||
|
LSWM1SUPD1 |
9803A1N8 9803A1N9 |
Yes |
No |
No |
|
LSWM1SUPX1 |
0231AMNQ 0231AMNS |
No |
No |
Yes |
The S9827-128DH or S9827-64EP switch can operate correctly with two power supplies. You can install three power supplies for 2+1 redundancy or four power supplies for 2+2 redundancy.
The S9827-64E switch can operate correctly with one power supply. You can install two power supplies for 1+1 redundancy.
To ensure heat dissipation, make sure all fan module slots are installed with fan modules and install fan modules of the same model on the switch as a best practice.
Power supplies
|
WARNING! When the switch has power supplies in redundancy, you can replace a power supply without powering off the switch. To avoid device damage and personal injury, make sure the power supply is powered off before you replace it. |
You can select power supplies as needed for the switch.
2000W AC power supply (PSR2000-12A-C-A/PSR2000-12A-C-B)
Figure3-1 PSR2000-12A-C-A/PSR2000-12A-C-B power supply
|
(1) AC power input receptacle |
(2) Status LED |
|
(3) Latch |
(4) Handle |
For information about the status LED, see "Power supply status LED."
Features
PSR2000-12A-C-A/PSR2000-12A-C-B is a power supply with AC or HVDC input and DC output. It can provide up to 2000 W of output. Table3-2 describes the features provided by the PSR2000-12A-C-A/PSR2000-12A-C-B power supply.
Table3-2 Features provided by the PSR2000-12A-C-A/PSR2000-12A-C-B power supply
|
Feature |
Description |
|
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
|
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
|
Support for hot swapping |
You can remove one of the power supplies in redundancy when the device is operating. |
Technical specifications
Table3-3 Technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) (handle included) |
40 × 73.5 × 185 mm (1.57 × 2.89 × 7.28 in) |
|
Weight |
0.75 kg (1.65 lb) |
|
Rated AC input voltage range |
100 VAC to 240 VAC @ 50 or 60 Hz |
|
Max AC input voltage range |
90 VAC to 264 VAC |
|
Rated HVDC input voltage |
240 VDC |
|
Max HVDC input voltage range |
180 VDC to 320 VDC |
|
Rated input current |
12A Max @ 100 VAC to 240 VAC 10A Max @ 240 VDC |
|
Rated output current |
164 A |
|
Rated output voltage |
12.2 V |
|
Rated output power |
2000 W |
|
Melting current of power supply fuse |
15 A |
|
Max output current |
164 A |
|
Max power |
2000 W |
2000W AC power supply (PSR2000-12A-S/PSR2000-12A-S-B)
Figure3-2 PSR2000-12A-S/PSR2000-12A-S-B power supply

|
(1) AC power input receptacle |
(2) Status LED |
|
(3) Latch |
(4) Handle |
Features
PSR2000-12A-S/PSR2000-12A-S-B is a power supply with AC or HVDC input and DC output. It can provide up to 2000 W of output. Table3-4 describes the features provided by the PSR2000-12A-S/PSR2000-12A-S-B power supply.
Table3-4 Features provided by the PSR2000-12A-S/PSR2000-12A-S-B power supply
|
Feature |
Description |
|
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
|
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
|
Support for hot swapping |
You can remove one of the power supplies in redundancy when the device is operating. |
Technical specifications
Table3-5 Technical specifications
|
Item |
PSR2000-12A-S |
PSR2000-12A-S-B |
|
Dimensions (H × W × D) (handle included) |
40 × 73.5 × 185 mm (1.57 × 2.89 × 7.28 in) |
|
|
Weight |
0.935 kg (2.06 lb) |
0.945 kg (2.08 lb) |
|
Rated AC input voltage range |
100 VAC to 240 VAC |
|
|
Max AC input voltage range |
90 VAC to 264 VAC |
|
|
Rated HVDC input voltage |
240 VDC |
|
|
Max HVDC input voltage range |
180 VDC to 320 VDC |
|
|
Rated input current |
10 A |
|
|
Rated output current |
164 A |
|
|
Rated output voltage |
12.2 V |
|
|
Rated output power |
2000 W |
|
|
Melting current of power supply fuse |
15 A |
|
|
Max output current |
164 A |
|
|
Max power |
2000 W |
|
2700W AC power supply (PSR2700-12A-A)
Figure3-3 PSR2700-12A-A power supply
|
(1) AC power input receptacle |
(2) Status LED |
|
(3) Latch |
(4) Handle |
Features
PSR2700-12A-A is a power supply with AC or HVDC input and DC output. It can provide up to 2700 W of output. Table3-6 describes the features provided by the PSR2700-12A-A power supply.
Table3-6 Features provided by the PSR2700-12A-A power supply
|
Feature |
Description |
|
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
|
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
|
Support for hot swapping |
You can remove one of the power supplies in redundancy when the device is operating. |
Technical specifications
Table3-7 Technical specifications
|
Item |
Specification |
|
Dimensions (H × W × D) (handle included) |
40 × 73.5 × 185 mm (1.57 × 2.89 × 7.28 in) |
|
Weight |
0.94 kg (2.07 lb) |
|
Rated AC input voltage range |
100 VAC to 240 VAC |
|
Max AC input voltage range |
90 VAC to 264 VAC |
|
Rated HVDC input voltage |
240 VDC |
|
Max HVDC input voltage range |
180 VDC to 320 VDC |
|
Rated input current |
16 A |
|
Rated output current |
221.4 A |
|
Rated output voltage |
12.2 V |
|
Rated output power |
2700 W |
|
Melting current of power supply fuse |
20 A |
|
Max output current |
221.4 A |
|
Max power |
2700 W |
Fan modules
|
CAUTION: The S9827-128DH and S9827-64EP switches each have eight fan module slots. The S9827-64E switch has four fan module slots. To ensure good ventilation of the switch, follow these guidelines to install and remove fan modules: · The switch comes with the fan module slots empty. As a best practice to ensure adequate heat dissipation, install fan modules of the same model on the switch. Before powering on the switch, make sure the number of installed fan modules meets the minimum requirement. · Make sure all slots have a module or filler panel installed when the switch is operating. · If multiple fan modules fail on an operating switch, do not remove the fan modules at the same time. Replace the fan modules one after another and finish replacing each fan module within 3 minutes. |
FAN-80B-1-C
Figure3-4 FAN-80B-1-C fan module
For information about the alarm LED, see "Fan module alarm LED."
Features
The FAN-80B-1-C fan module draws air from the port side to the fan module faceplate side. The fan module is small, hot swappable, and can automatically adjust the fan speed according to the device temperature.
Technical specifications
Table3-8 FAN-80B-1-C fan module specifications
|
Item |
Specification |
|
Dimensions (H × W × D) (handle included) |
80 × 80 × 136 mm (3.15 × 3.15 × 5.35 in) |
|
Weight |
0.5 kg (1.10 lb) |
|
Airflow direction |
Air exhausted from the fan module faceplate |
|
Max fan speed |
Inlet: 16000 R.P.M Outlet: 14000 R.P.M |
|
Max airflow |
163.92 CFM (4.64 m3/min) |
|
Input voltage |
12 V |
|
Max power consumption |
105.6 W |
FAN-80B-1-D
Figure3-5 FAN-80B-1-D fan module
For information about the alarm LED, see "Fan module alarm LED."
Features
The FAN-80B-1-D fan module draws air from the port side to the fan module faceplate side. The fan module is small, hot swappable, and can automatically adjust the fan speed according to the device temperature.
Technical specifications
Table3-9 FAN-80B-1-D fan module specifications
|
Item |
Specification |
|
Dimensions (H × W × D) (handle included) |
80 × 80 × 175.6 mm (3.15 × 3.15 × 6.91 in) |
|
Weight |
0.6 kg (1.32 lb) |
|
Airflow direction |
Air exhausted from the fan module faceplate |
|
Max fan speed |
16900 R.P.M |
|
Max airflow |
128 CFM (3.62 m3/min) |
|
Input voltage |
12 V |
|
Max power consumption |
158 W |
SEMs
LSWM1SUPD1
Figure3-6 LSWM1SUPD1 SEM
Technical specifications
Table3-10 LSWM1SUPD1 SEM specifications
|
Item |
Specification |
||
|
Weight |
1.90 kg (4.19 lb) |
||
|
Dimensions (H × W × D) |
151 × 33.5 × 309 mm (5.94 × 1.32 × 12.17 in) |
||
|
Power consumption |
45 W |
||
|
Processor |
4 cores, 2.6 GHz |
||
|
SDRAM |
16 GB |
||
|
Flash |
64 GB |
||
|
NVRAM |
N/A |
||
|
Connector type |
· RJ-45 · USB (Type A) |
||
|
Ports |
· 1 × console port · 1 × USB port · 1 × RJ-45 network management port |
||
|
Port transmission speed |
· Console port: 9600 (default) to 115200 bps · RJ-45 network management port: 10/100/1000 Mbps, half/full duplex |
||
|
Hot swapping |
Supported |
||
|
Compatible switch model |
S9827-128DH |
Front view
Figure3-7 LSWM1SUPD1 SEM front view
|
(1) Network management port |
(2) USB port |
|
(3) System status LED (SYS) |
(4) Power status LED (PSU) |
|
(5) Fan module status LED (FAN) |
(6) Location LED (ID) |
|
(7) Reset button (RESET) |
(8) Copper management Ethernet port LED (LINK) |
|
(9) Copper management Ethernet port LED (ACT) |
|
LSWM1SUPX1
Figure3-8 LSWM1SUPX1 SEM
Technical specifications
Table3-11 LSWM1SUPX1 SEM specifications
|
Item |
Specification |
||
|
Weight |
1.90 kg (4.19 lb) |
||
|
Dimensions (H × W × D) |
151 × 33.5 × 309 mm (5.94 × 1.32 × 12.17 in) |
||
|
Power consumption |
45 W |
||
|
Processor |
4 cores, 2.6 GHz |
||
|
SDRAM |
16 GB |
||
|
Flash |
64 GB |
||
|
NVRAM |
N/A |
||
|
Connector type |
· RJ-45 · USB (Type A) |
||
|
Ports |
· 1 × console port · 1 × USB port · 1 × RJ-45 network management port |
||
|
Port transmission speed |
· Console port: 9600 (default) to 115200 bps · RJ-45 network management port: 10/100/1000 Mbps, half/full duplex |
||
|
Hot swapping |
Supported |
||
|
Compatible switch model |
S9827-64EP |
Front view
Figure3-9 LSWM1SUPX1 SEM front view

|
(1) Network management port |
(2) USB port |
|
(3) System status LED (SYS) |
(4) Location LED (ID) |
|
(5) Power status LED (PSU) |
(6) Fan module status LED (FAN) |
|
(7) Reset button (RESET) |
(8) Copper management Ethernet port LED (LINK) |
|
(9) Copper management Ethernet port LED (ACT) |
|
4 Ports
As a best practice, use H3C transceiver modules and cables for the switch. H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact H3C Support or marketing staff.
For information about the specifications of H3C transceiver modules and cables, see H3C Transceiver Modules User Guide.
Console port
The switch has a serial console port.
Table4-1 Console port specifications
|
Item |
Serial console port |
|
Connector type |
RJ-45 |
|
Compliant standard |
EIA/TIA-232 |
|
Operating mode |
Duplex Universal Asynchronous Receiver/Transmitter (duplex UART) |
|
Transmission baud rate |
9600 bps (default) to 115200 bps |
|
Services |
· Provides connection to an ASCII terminal. · Provides connection to the serial port of a local terminal (a PC for example) running a terminal emulation program. |
Management Ethernet port
The switch has one copper management Ethernet port. You can connect the port to a local PC for software loading and debugging or to a remote management station for remote management.
Table4-2 Management Ethernet port specifications
|
Item |
Specification |
|
Connector type |
RJ-45 |
|
Connector count |
1 × 10/100/1000BASE-T management port |
|
Compliant standard |
10/100/1000BASE-T management port: IEEE802.3ab |
|
Port transmission rate, duplex mode, and auto MDI/MDI-X |
· 10/100 Mbps, half/full duplex, auto MDI/MDI-X. · 1000 Mbps, full duplex, auto MDI/MDI-X. |
|
Transmission medium and max transmission distance |
10/100/1000BASE-T management port: 100 m (328.08 ft) over category-5 UTP cable. |
|
Functions and services |
Software upgrade and network management. |
USB port
The switch has one OHCI-compliant USB 3.0 port that can upload and download data at a rate up to 5 Gbps. You can use this USB port to access the file system on the flash of the switch, for example, to upload or download application and configuration files.
The USB port supplies power as per USB 3.0 specifications. Use only USB 3.0-compliant USB devices for the USB port. The port might not identify USB devices that are not compliant with USB 3.0.
|
|
NOTE: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices of all vendors on the switch. If a USB device fails to operate on the switch, replace it with one from another vendor. |
OSFP800 port
Table4-3 OSFP800 port specifications
|
Item |
Specification |
|
Port name |
800GE OSFP800 fiber port |
|
Product compatibility |
The S9827-64EP switch provides 64 OSFP800 ports on the front panel |
|
Connector |
· MPO · LC |
|
Description |
The 800GE OSFP800 fiber ports are mainly used for transmitting and receiving 800GE fiber port services and are compatible with 800 Gbps and 400 Gbps rates |
|
Compliant standard |
IEEE802.3ck |
|
Fiber port attribute |
Depends on the transceiver module or cable installed |
|
Operating mode |
Full duplex |
|
Available transceiver modules and cables |
See H3C S9827 Switch Series Transceiver Module Compatibility Matrix |
|
Support for interface splitting |
See H3C Data Center Fixed-Port Switches Support for Interface Splitting |
|
Restrictions and guidelines |
N/A |
QSFP112 port
Table4-4 QSFP112 port specifications
|
Item |
Specification |
|
Port name |
400GE QSFP112 fiber port |
|
Product compatibility |
The S9827-128DH switch provides 128 QSFP112 ports on the front panel |
|
Connector |
· MPO · LC |
|
Description |
The 400GE QSFP112 fiber ports are mainly used for transmitting and receiving 400GE fiber port services and are compatible with 200 Gbps and 100 Gbps rates |
|
Compliant standard |
· IEEE802.3ba · IEEE802.3ck · IEEE802.3bm |
|
Fiber port attribute |
Depends on the transceiver module or cable installed |
|
Operating mode |
Full duplex |
|
Available transceiver modules and cables |
See H3C S9827 Switch Series Transceiver Module Compatibility Matrix |
|
Support for interface splitting |
See H3C Data Center Fixed-Port Switches Support for Interface Splitting |
|
Restrictions and guidelines |
N/A |
QSFP-DD800 port
Table4-5 QSFP-DD800 port specifications
|
Item |
Specification |
|
Port name |
800GE QSFP-DD800 fiber port |
|
Product compatibility |
The S9827-64E switch provides 64 QSFP-DD800 ports on the front panel |
|
Connector |
· MPO · LC |
|
Description |
The 800GE QSFP-DD800 fiber ports are mainly used for transmitting and receiving 800GE fiber port services and are compatible with 800 Gbps, 400 Gbps, 200 Gbps, and 100 Gbps rates |
|
Compliant standard |
· IEEE802.3ba · IEEE802.3ck · IEEE802.3bm |
|
Fiber port attribute |
Depends on the transceiver module or cable installed |
|
Operating mode |
Full duplex |
|
Available transceiver modules and cables |
See H3C S9827 Switch Series Transceiver Module Compatibility Matrix |
|
Support for interface splitting |
See H3C Data Center Fixed-Port Switches Support for Interface Splitting |
|
Restrictions and guidelines |
N/A |
SFP+ port
Table4-6 SFP+ port specifications
|
Item |
Specification |
|
Port name |
10GE SFP+ fiber port |
|
Product compatibility |
The S9827-64E switch provides two SFP+ ports on the front panel |
|
Connector |
LC |
|
Description |
The 10GE SFP+ fiber ports are mainly used for transmitting and receiving GE/10GE fiber port services |
|
Compliant standard |
IEEE802.3ae |
|
Fiber port attribute |
Depends on the transceiver module or cable installed |
|
Operating mode |
Full duplex |
|
Available transceiver modules and cables |
· 10G SFP+ modules · 10G SFP+ copper cables · 10G SFP+ AOC cables · 1G SFP modules For more information, see H3C S9827 Switch Series Transceiver Module Compatibility Matrix |
|
Support for interface splitting |
See H3C Data Center Fixed-Port Switches Support for Interface Splitting |
|
Restrictions and guidelines |
N/A |
5 LEDs
System status LED
The system status LED shows the operating status of the switch.
Table5-1 System status LED description
|
LED mark |
Status |
Description |
|
SYS |
Steady green |
The switch is operating correctly. |
|
Flashing green |
The switch is performing power-on self-test (POST). |
|
|
Steady red |
The system has failed to pass POST or a fault has occurred. |
|
|
Steady yellow |
Some ports have failed to pass POST and cannot operate correctly. |
|
|
Flashing blue (3 Hz) |
Helps identify the switch. The S9827-128DH switch uses the ID LED to locate the device with the LED in flashing blue at 2 Hz. To identify the switch location, execute the locator blink blink-time command. This LED will flash blue at 3 Hz. |
|
|
Off |
The switch is powered off or has failed to start up. |
OSFP800 port LED
Table5-2 OSFP800 port LED description
|
LED status |
Description |
|
Steady green |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at 800 Gbps. |
|
Flashing green |
The port is sending or receiving data at 800 Gbps. |
|
Steady yellow |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at 400 Gbps. |
|
Flashing yellow |
The port is sending or receiving data at 400 Gbps. |
|
Off |
No transceiver module or cable has been installed in the port, or no link is present on the port. |
QSFP112 port LED
Table5-3 QSFP112 port LED description
|
LED status |
Description |
|
Steady green |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at 400 Gbps. |
|
Flashing green |
The port is sending or receiving data at 400 Gbps. |
|
Steady yellow |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at non-400 Gbps. |
|
Flashing yellow (3 Hz) |
The port is sending or receiving data at non-400 Gbps. |
|
Off |
No transceiver module or cable has been installed in the port, or no link is present on the port. |
QSFP-DD800 port LED
Table5-4 QSFP-DD800 port LED description
|
LED status |
Description |
|
Steady green |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at 800 Gbps. |
|
Flashing green |
The port is sending or receiving data at 800 Gbps. |
|
Steady yellow |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at 400/200/100 Gbps. |
|
Flashing yellow |
The port is sending or receiving data at 400/200/100 Gbps. |
|
Off |
No transceiver module or cable has been installed in the port, or no link is present on the port. |
SFP+ port LED
Table5-5 SFP+ port LED description
|
LED status |
Description |
|
Steady green |
A transceiver module or cable has been correctly installed in the port. The port has a link and is operating at 1/10 Gbps. |
|
Flashing green |
The port is sending or receiving data at 1/10 Gbps. |
|
Off |
No transceiver module or cable has been installed in the port, or no link is present on the port. |
Management Ethernet port LEDs
The switch provides a LINK/ACT LED for the copper management Ethernet port to indicate its operating status.
Table5-6 Copper management Ethernet port LED description
|
LED mark |
Status |
Description |
|
LINK |
Off |
No link is present on the port. |
|
Steady green |
The port is operating at 10/100/1000 Mbps. |
|
|
ACT |
Off |
The port is not receiving or sending data. |
|
Flashing yellow |
The port is receiving or sending data. |
Power supply status LED
A power supply provides a status LED to indicate the status of power input and power output.
Table5-7 Description for the status LED on a power supply
|
Status |
Description |
|
Steady green |
The power supply is operating correctly. |
|
Flashing green at 1 Hz |
The power supply has power input, and the system is in standby state and has not been powered on. |
|
Flashing green at 0.33 Hz |
The power supply is in cold standby state with no power output. |
|
Flashing green at 2 Hz |
The power supply firmware is being upgraded. |
|
Steady amber |
· A severe fault occurs on the power supply · The power supply has no power input but the other power supply has power input. |
|
Steady amber at 1 Hz |
An alarm occurs on the power supply. |
|
Off |
The power supply does not have power input due to one of the following conditions: · The power cable is connected incorrectly. · The external power system is powered off. |
Fan module alarm LED
Each fan module has an alarm LED.
Table5-8 Description for the alarm LED on a fan module
|
Status |
Description |
|
Steady green |
The fan module is operating correctly. |
|
Steady red |
The fan module is faulty. |
|
Off |
The fan module is operating correctly or no power is present. |
Power status LED
The switch provides a power status LED on the panel to indicate the operating status of the power supplies in the chassis.
Table5-9 Description for the power status LED on the S9827-128DH switch
|
LED mark |
Status |
Description |
|
PSU |
Steady green |
The power supplies are operating correctly. |
|
Steady yellow |
The number of the faulty or absent power supplies is 1 |
|
|
Steady red |
The number of the faulty or absent power supplies is equal to or greater than 2. |
|
|
Off |
The switch is powered off. |
Table5-10 Description for the power status LED on the S9827-64EP switch
|
LED mark |
Status |
Description |
|
PSU |
Steady green |
The power supplies are operating correctly. |
|
Steady yellow |
The number of the faulty or absent power supplies is equal to or less than 2. |
|
|
Steady red |
The number of the faulty or absent power supplies is greater than 2. |
|
|
Off |
The switch is powered off. |
Table5-11 Description for the power status LED on the S9827-64E switch
|
LED mark |
Status |
Description |
|
PSU |
Steady green |
The power supplies are operating correctly. |
|
Steady yellow |
The number of the faulty or absent power supplies is 1. |
|
|
Off |
The number of the faulty or absent power supplies is 2 or the switch is powered off. |
Fan module status LED
The switch provides a fan module status LED on the panel to indicate the operating status of the fan modules in the chassis.
Table5-12 Fan module status LED
|
LED mark |
Status |
Description |
|
FAN |
Steady green |
The fan modules are operating correctly. |
|
Steady yellow |
The number of the faulty or absent fan modules is 1 |
|
|
Steady red |
The number of the faulty or absent fan modules is equal to or greater than 2. |
6 Cooling system
|
CAUTION: The chassis and power supplies use separate air aisles. Make sure the two aisles are not blocked when the switch is operating. |
The switch uses a highly efficient front-rear air aisle cooling system to ensure adequate heat dissipation and improve system reliability. Consider the ventilation design at the installation site when you plan the installation location for the switch.
Table6-1 Fan module options for the switch
|
Switch model |
Available fan module |
Airflow direction of the chassis |
|
S9827-128DH |
FAN-80B-1-C |
From the port side to the power supply side The following figure uses the LS-9827-128DH switch as an example. |
|
S9827-64E S9827-64EP |
FAN-80B-1-D |