1 Product models and technical specifications

Product models

This document is applicable to the S12500R-48C6D (product code LS-12500R-48C6D).

Technical specifications

Table1-1 Technical specifications

Item

S12500R-48C6D

Product code

LS-12500R-48C6D

Dimensions (H × W × D)

65.5 × 440 × 660 mm (2.58 × 17.32 × 25.98 in)

Weight

≤ 20 kg (44.09 lb)

Console port

1

Management Ethernet port

1

USB port

1

QSFP28 port

48 (ports 4, 6, 7, 9, 10, 12, 13, 15, 16, 18, 19, 21, 28, 30, 31, 33, 34, 36, 37, 39, 40, 42, 43, and 45 can operate as QSFP56 ports)

QSFP-DD port

6

SMB clock input port

1

SMB clock output port

1

1PPS/ToD time synchronization port

1

Fan tray slot

6

Power supply slot

2

Static power consumption

(configured with no transceiver modules or cables, at no load)

352W

Typical power consumption

(fully configured with cables, at 50% load)

572W

Maximum power consumption

(fully configured with transceiver modules, at 100% load)

1008W

Chassis leakage current compliance

·     GB 4943.1

·     IEC 60950-1

·     IEC 62368-1

·     EN 62368-1

·     UL 62368-1

Sound pressure level at 27°C (80.6°F)

66.7 dB(A)

Operating temperature

0°C to 40°C (32°F to 104°F)

Operating humidity

5% RH to 95% RH, noncondensing

Storage humidity

5% RH to 95% RH, noncondensing

Fire resistance compliance

·     GB 4943.1

·     IEC 60950-1

·     IEC 62368-1

·     EN 62368-1

·     UL 62368-1

 


2 Chassis views

Figure2-1 Front panel

(1) QSFP28 port

(2) QSFP28 port LED

(3) QSFP28/QSFP56 port

(4) QSFP28/QSFP56 port LED

(5) QSFP-DD port

(6) QSFP-DD port LED

(7) Fan tray status LED (FAN)

(8) Power status LED (PSU)

(9) System status LED (SYS)

 

The pink-marked QSFP28 ports on the front panel can operate as QSFP56 ports.

Figure2-2 Rear panel

(1) Power supply 1

(2) Management Ethernet port LED (ACT)

(3) Management Ethernet port (MGMT)

(4) Management Ethernet port LED (LINK)

(5) SMB clock output port

(6) SMB clock input port

(7) Fan tray 1

(8) Fan tray 2

(9) Fan tray 3

(10) Fan tray 4

(11) Fan tray 5

(12) Fan tray 6

(13) Grounding screw 1

(14) Grounding screw 2

(15) Power supply 2

(16) Reset button

(17) System status LED (SYS)

(18) 1PPS/ToD time synchronization port

(19) Console port

(20) USB port

 

The S12500R-48C6D came with power supply slot PSU1 empty and power supply slot PSU2 installed with a filler panel. You can install one or two power supplies for the device as needed. In Figure2-2, two PSR1600C-12A-B power supplies are installed in the power supply slots.

The S12500R-48C6D came with the six fan tray slots empty. You must install six fan trays of the same model for the device. In Figure2-2, six FAN-40B-1-C fan trays are installed in the fan tray slots.

The S12500R-48C6D provides a reset button on the rear panel for you to reset the device.


3 FRUs

The device uses modular design. Table3-1 describes the FRUs available for the device.

Table3-1 FRUs available for the device

FRUs

BOM code

S12500R-48C6D

Power supplies

PSR1600C-12A-B

9803A00H

Yes

Fan trays

FAN-40B-1-C

9803A00F

Yes

 

The device can operate correctly with only one power supply. You can install two power supplies for 1+1 redundancy.

To ensure heat dissipation, make sure all fan tray slots on the device have fan trays installed and the fan trays are the same model.

Power supplies

CAUTION

CAUTION:

When the device has power supplies in redundancy, you can replace a power supply without powering off the device. Make sure the power supply to be replaced is powered off before you replace it.

 

Table3-2 Power supply specifications

Power supply model

Specifications

Remarks

PSR1600C-12A-B

·     Rated AC input voltage: 100 VAC to 240 VAC @ 50 Hz or 60 Hz

·     Rated HVDC input voltage range: 180 VDC to 320 VDC

·     Max output power: 1600 W

For more information about the power supply, see H3C PSR1600C-12A-B Power Module User Manual.

 

Fan trays

Table3-3 Fan tray specifications

Fan tray model

Item

Specifications

FAN-40B-1-C (air exhaust on fan tray panel)

Dimensions (H × W × D, including the handle)

40 × 40 × 136 mm (1.57 × 1.57 × 5.35 in)

Fan speed

29000 R.P.M

Max airflow

38 CFM (1.08 m3/min)

Input voltage

12 V

Max power consumption

60 W

Documentation reference

H3C FAN-40B-1-C Fan Tray User Guide

 


4 Ports and LEDs

As a best practice, use H3C transceiver modules and cables for the device. H3C transceiver modules and cables are subject to change over time. For the most up-to-date list of H3C transceiver modules and cables, contact H3C Support or marketing staff. For information about the specifications and views of H3C transceiver modules and cables, see H3C Transceiver Modules User Guide.

Ports

Console port

The device has one serial console port.

Table4-1 Console port specifications

Item

Console port

Connector type

RJ-45

Compliant standard

EIA/TIA-232

Transmission baud rate

9600 bps (default) to 115200 bps

Services

·     Provides connection to an ASCII terminal.

·     Provides connection to the serial port of a local PC running terminal emulation program.

 

Management Ethernet port

The device has one management Ethernet port. You can connect the port to a local PC for software loading and debugging or to a remote management station for remote management.

Table4-2 Management Ethernet port specifications

Item

Specifications

Connector type

RJ-45/LC

Port transmission rate

10/100/1000BASE-T management port:

·     10/100 Mbps, half/full duplex, MDI/MDI-X auto-sensing.

·     1000 Mbps, full duplex, MDI/MDI-X auto-sensing.

Transmission medium and max transmission distance

100 m (328.08 ft) over category 5 UTP cable.

Functions and services

Software upgrade and network management.

 

USB port

The device has one OHCI-compliant USB 2.0 port that can upload and download data at a rate up to 480 Mbps. You can use this USB port to access the file system on the Flash of the device, for example, to upload or download application and configuration files.

The USB port supplies power as per USB 2.0 specifications. Use only USB 2.0-compliant USB devices for the USB port. The port might not identity USB devices that are not compliant with USB 2.0.

 

 

NOTE:

USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices from other vendors on the device. If a USB device fails to operate on the device, replace it with one from another vendor.

 

QSFP28/QSFP56 port

The device provides 48 QSFP28 ports on the front panel. Ports 4, 6, 7, 9, 10, 12, 13, 15, 16, 18, 19, 21, 28, 30, 31, 33, 34, 36, 37, 39, 40, 42, 43, and45 can operate as QSFP56 ports.

For information about available transceiver modules or cables for the ports, see H3C S12500R-48C6D Switch Router Transceiver Modules Compatibility Matrix.

QSFP-DD port

The device provides six QSFP-DD ports on the front panel. For information about available transceiver modules or cables for the ports, see H3C S12500R-48C6D Switch Router Transceiver Modules Compatibility Matrix.

Clock ports

SMB clock input/output port

Table4-1 SMB clock input/output port specifications

Item

Specifications

Connector type

SMB coaxial

Port standard

GJB681

Supported services

Sends and receives 2.048 MHz clocks and 2.048 Mbps signals to synchronize clocks between the device and other network devices or endpoints.

 

1PPS/ToD time synchronization port

Table4-2 1PPS/ToD time synchronization port specifications

Item

Specifications

Connector type

RJ-45

Port standard

QB-B-016-2010

Supported services

·     You can configure the port as an input port or output port at the CLI.

·     Synchronizes clocks of the device and other network devices, such as GPS receivers and endpoints.

 

LEDs

System status LED

The system status LED shows the operating status of the device.

Table4-3 System status LED description

LED mark

Status

Description

SYS

Steady green

The device is operating correctly.

Flashing green

The device is performing power-on self test (POST).

Steady red

The system POST has failed or a system failure has occurred.

Flashing red

Some ports failed in POST and do not work.

NOTE:

The system does not perform POST if the BootWare boot mode is fast mode.

Flashing blue (3 Hz)

Helps you to locate the device.

To locate the device in the rack, execute the locator blink blink-time command. The LED then flashes blue at 3 Hz.

Off

The device is powered off or has failed to start up.

 

Management Ethernet port LEDs

The device provides two status LEDs LINK and ACT for the management Ethernet port.

Table4-4 Management Ethernet port LED description

LED mark

Status

Description

LINK

Off

No link is present on the port

Steady green

The port is operating at 10/100/1000 Mbps.

ACT

Off

The port is not receiving or sending data.

Flashing yellow

The port is sending or receiving data.

 

QSFP28/QSFP56 port LED

Table4-5 QSFP28/QSFP56 port LED description

LED status

Description

Steady green

A transceiver module or cable has been correctly installed and a link is present on the port.

Flashing green

The port is sending or receiving data.

Off

No transceiver module or cable has been installed or no link is present on the port.

 

QSFP-DD port LED

Table4-6 QSFP-DD port LED description

LED status

Description

Flashing

The port is sending or receiving data.

On

A link is present on the port.

Off

No link is present on the port.

 

Power status LED

The device provides a power status LED to indicate the operating status of the power supplies.

Table4-7 Power status LED description

Mark

Status

Description

PSU

Steady green

Both power supplies are operating correctly.

Steady yellow

A power supply has failed or is not present.

Off

Both power supplies have failed or are not present.

 

Fan tray status LED

The device provides a fan tray status LED to indicate the operating status of the fan trays.

Table4-8 Fan tray status LED description

Mark

Status

Description

FAN

Steady green

All fan trays are operating correctly.

Steady yellow

A fan tray has failed or is not present.

Steady red

A minimum of two fan trays have failed or are not present.

 

Fan tray alarm LED

Each fan tray provides an alarm LED.

Table4-9 Description for the alarm LEDs on the fan trays

Status

Description

Steady green

The fan tray is operating correctly.

Steady red

The fan tray has failed.

Off

The fan tray is not installed securely or no power is present.

 


5 Cooling system

CAUTION

CAUTION:

The chassis and power supplies use separate air aisles. Make sure the two aisles are not blocked when the device is operating.

 

To dissipate heat timely and ensure system stability, the device uses the front-rear air aisle cooling system. Consider the site ventilation design when you plan the installation site for the device.

Table5-1 Cooling system for the device

Device model

Available fan trays

Airflow direction

S12500R-48C6D

FAN-40B-1-C

From the port side to the power supply side

 

Figure5-1 Airflow from the port side to the power supply side through the chassis

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us