1 Product models and technical specifications
3 FRUs and compatibility matrixes
550W AC power supply (SW-A-PSR550-12A-B)
550W AC power supply (SW-B-PSR550-12A-B)
2000W AC power supply (PSR2000-12A-S)
2000W AC power supply (PSR2000-12A-S-B)
Location and system status LED
Status LED on an SW-A-PSR550-12A-B/SW-B-PSR550-12A-B power supply
Status LED on a PSR2000-12A-S/PSR2000-12A-S-B power supply
1 Product models and technical specifications
Product models
The H3C S12500AI switch series includes the following models:
Switch series |
Model |
Product code (PID) |
H3C S12500AI switch series |
H3C S12500AI-6C-NCCA |
LS-12500AI-6C-NCCA |
H3C S12500AI-96B-NCFK |
LS-12500AI-96B-NCFK |
|
H3C S12500AI-36B48B-NCPK |
LS-12500AI-36B48B-NCPK |
|
H3C S12500AI-18D48B-NCPK |
LS-12500AI-18D48B-NCPK |
Technical specifications
NCC switch
Table1-1 NCC switch technical specifications
Item |
LS-12500AI-6C-NCCA |
Physical specifications |
|
Dimensions (H × W × D) |
44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
Dimensions (H × W × D, with package materials) |
180 × 576 × 638 mm (7.09 × 22.68 × 25.12 in) |
Weight |
≤ 10 kg (22.05 lb) |
Technical specifications |
|
Processor |
8 cores, 2.2 GHz |
DRAM memory |
64 GB |
NOR flash |
32 MB × 2 |
NAND flash |
eMMC 64G |
Port types and quantity |
|
Console port |
1 |
Management Ethernet port |
1 |
USB port |
1 |
SMB coaxial clock port |
Input: 1 Output: 1 |
SFP HP-GE port |
1 |
1PPS/TOD port |
1 |
SFP28 IPC port |
2 |
QSFP28 IPC port |
6 |
Fan trays and power supplies |
|
Fan tray slot |
4 |
Power supply slot |
2 |
Power supply specifications |
|
Power input |
AC input, HVDC input |
Power specifications |
See "Power supplies" |
System power consumption |
|
Typical power consumption (Fully configured with cables, 50% loaded) |
120 W |
Maximum power consumption (Fully configured with transceiver modules, 100% loaded) |
300 W |
System thermal consumption |
|
Typical thermal consumption |
409.45 BTU/h |
Maximum thermal consumption |
716.54 BTU/h |
Heat dissipation |
|
Heat dissipation method |
Air cooling |
Ventilation aisles |
Front-to-rear |
Reliability and availability |
|
Power supply redundancy |
1+1 redundancy |
Fan tray redundancy |
3+1 redundancy |
Hot swapping |
Power supplies and fan trays support hot swapping |
Mean time between failure (MTBF) (year) |
52.8 |
Mean time to repair (MTTR) (hour) |
0.5 |
Availability |
99.9999% |
Environment specifications |
|
Sound pressure level at 27°C (80.6°F) |
41.8 dBA |
Altitude |
–60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Operating temperature |
0°C to 40°C (32°F to 104°F) Note: The allowed maximum temperature decreases by 0.33 °C (32.59°F) as the altitude increases by 100 m (328.08 ft) from 0 m (0 ft). |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Relative humidity |
5% RH to 95% RH, noncondensing |
Product compliance |
|
Product compliance |
· Safety standards · EMC standards · Environmental and eco-friendly standards |
NCF switch
Table1-2 NCF switch technical specifications
Item |
LS-12500AI-96B-NCFK |
Physical specifications |
|
Dimensions (H × W × D) |
130.5 × 440 × 760 mm (5.14 × 17.32 × 29.92 in) |
Dimensions (H × W × D, with package materials) |
391 × 655 × 1092 mm (15.39 × 25.79 × 42.99 in) |
Weight (fully configured) |
≤ 25 kg (55.11 lb) |
Technical specifications |
|
Processor |
4 cores, 2.9 GHz |
DRAM memory |
32 GB |
NOR flash |
32 MB × 2 (primary and backup) |
NAND flash |
eMMC 4G |
Port types and quantity |
|
Console port |
1 |
Management Ethernet port |
1 |
USB port |
1 |
SFP+ IPC port |
2 |
QSFP56 SFI port |
96 |
Fan trays and power supplies |
|
Fan tray slot |
4 |
Power supply slot |
2 |
Power supply specifications |
|
Power input |
AC input, HVDC input |
Power specifications |
See "Power supplies" |
System power consumption |
|
Typical power consumption (Fully configured with cables, 50% loaded) |
Single AC input: 560 W Dual AC inputs: 605 W |
Maximum power consumption (Fully configured with transceiver modules, 100% loaded) |
Single AC input: 1720 W Dual AC inputs: 1730 W |
System thermal consumption |
|
Typical thermal consumption |
Single AC input: 1910.78 BTU/h Dual AC inputs: 2064.32 BTU/h |
Maximum thermal consumption |
Single AC input: 4108.17 BTU/h Dual AC inputs: 4132.05 BTU/h |
Heat dissipation |
|
Heat dissipation method |
Air cooling |
Ventilation aisles |
Front-to-rear |
Reliability and availability |
|
Power supply redundancy |
1+1 redundancy |
Fan tray redundancy |
3+1 redundancy |
Hot swapping |
Power supplies and fan trays support hot swapping |
Mean time between failure (MTBF) (year) |
41.4 |
Mean time to repair (MTTR) (hour) |
0.5 |
Availability |
99.9999% |
Environment specifications |
|
Sound pressure level at 27°C (80.6°F) |
66.6 dBA |
Altitude |
–60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Operating temperature |
0°C to 40°C (32°F to 104°F) Note: The allowed maximum temperature decreases by 0.33 °C (32.59°F) as the altitude increases by 100 m (328.08 ft) from 0 m (0 ft). |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Relative humidity |
5% RH to 95% RH, noncondensing |
Product compliance |
|
Product compliance |
· Safety standards · EMC standards · Environmental and eco-friendly standards |
NCP switches
Table1-3 NCP switch technical specifications
Item |
LS-12500AI-36B48B-NCPK |
LS-12500AI-18D48B-NCPK |
Physical specifications |
||
Dimensions (H × W × D) |
88.1 × 440 × 760 mm (3.47 × 17.32 × 29.92 in) |
88.1 × 440 × 760 mm (3.47 × 17.32 × 29.92 in) |
Dimensions (H × W × D, with package materials) |
255 × 590 × 1135 mm (10.04 × 23.23 × 44.69 in) |
255 × 590 × 1135 mm (10.04 × 23.23 × 44.69 in) |
Weight (fully configured) |
≤ 25 kg (55.11 lb) |
≤ 25 kg (55.11 lb) |
Technical specifications |
||
Processor |
4 cores, 2.9 GHz |
4 cores, 2.9 GHz |
DRAM memory |
32 GB |
32 GB |
NOR flash |
32 MB × 2 (primary and backup) |
32 MB × 2 (primary and backup) |
NAND flash |
eMMC 4G |
eMMC 4G |
Port types and quantity |
||
Console port |
1 |
1 |
Management Ethernet port |
1 |
1 |
USB port |
1 |
1 |
SMB coaxial clock port |
Input: 1 Output: 1 |
Input: 1 Output: 1 |
SFP HP-GE port |
1 |
1 |
1PPS/TOD port |
1 |
1 |
SFP+ IPC port |
1 |
1 |
QSFP56 SFI port |
48 |
48 |
QSFP56 service port |
36 |
N/A |
QSFP-DD service port |
N/A |
18 |
Fan trays and power supplies |
||
Fan tray slot |
4 |
4 |
Power supply slot |
2 |
2 |
Power specifications |
||
Power input |
AC input, HVDC input |
|
Power specifications |
See "Power supplies" |
|
System power consumption |
||
Typical power consumption (Fully configured with cables, 50% loaded) |
Single AC input: 490 W Dual AC inputs: 510 W |
Single AC input: 490 W Dual AC inputs: 535 W |
Maximum power consumption (Fully configured with transceiver modules, 100% loaded) |
Single AC input: 1775 W Dual AC inputs: 1815 W |
Single AC input: 1850 W Dual AC inputs: 1860 W |
System thermal consumption |
||
Typical thermal consumption |
Single AC input: 1671.93 BTU/h Dual AC inputs: 1740.17 BTU/h |
Single AC input: 1671.93 BTU/h Dual AC inputs: 1825.47 BTU/h |
Maximum thermal consumption |
Single AC input: 4239.53 BTU/h Dual AC inputs: 4335.07 BTU/h |
Single AC input: 4418.67 BTU/h Dual AC inputs: 4442.55 BTU/h |
Heat dissipation |
||
Heat dissipation method |
Air cooling |
|
Ventilation aisles |
Front-to-rear |
|
Reliability and availability |
||
Power supply redundancy |
1+1 redundancy |
|
Fan tray redundancy |
3+1 redundancy |
|
Hot swapping |
Power supplies and fan trays support hot swapping |
|
Mean time between failure (MTBF) (year) |
39.37 |
39.43 |
Mean time to repair (MTTR) (hour) |
0.5 |
0.5 |
Availability |
99.9998% |
99.9998% |
Environment specifications |
||
Sound pressure level at 27°C (80.6°F) |
64.9 dBA |
64.0 dBA |
Altitude |
–60 m to +5000 m (–196.85 ft to +16404.20 ft) |
|
Operating temperature |
0°C to 40°C (32°F to 104°F) Note: The allowed maximum temperature decreases by 0.33 °C (32.59°F) as the altitude increases by 100 m (328.08 ft) from 0 m (0 ft). |
|
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
|
Relative humidity |
5% RH to 95% RH, noncondensing |
|
Product compliance |
||
Product compliance |
· Safety standards · EMC standards · Environmental and eco-friendly standards |
2 Chassis views
LS-12500AI-6C-NCCA
Figure2-1 LS-12500AI-6C-NCCA front panel
(1) SMB coaxial clock output port |
(2) SMB coaxial clock input port |
(3) 1PPS/TOD port |
(4) SFP HP-GE port |
(5) Serial console port |
(6) Copper management Ethernet port LED (ACT) |
(7) Copper management Ethernet port |
(8) Copper management Ethernet port LED (LINK) |
(9) USB port |
(10) Reset button (RESET) |
(11) SFP28 IPC port (2 in total) |
(12) QSFP28 IPC port (6 in total) |
(13) QSFP28 IPC port LED |
(14) SFP28 IPC port LED |
(15) Fan tray status LED (FAN) |
(16) Power supply status LED (PSU) |
(17) Primary/backup status LED (ACT) |
(18) Location and system status LED (ID/SYS) |
Figure2-2 LS-12500AI-6C-NCCA rear panel
(1) Power supply 1 |
(2) Fan tray 1 |
(3) Fan tray 2 |
(4) Fan tray 3 |
(5) Fan tray 4 |
(6) Grounding point |
(7) Power supply 2 |
The LS-12500AI-6C-NCCA switch came with the two power supply slots empty. You can install one or two power supplies for the switch as needed. In Figure2-2, two SW-A-PSR550-12A-B AC power supplies are installed in the power supply slots.
The LS-12500AI-6C-NCCA switch came with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure2-2, four FAN-40B-1-C fan trays are installed in the fan tray slots.
The LS-12500AI-6C-NCCA switch supports shipping with fan trays and power supplies installed. To purchase a switch preinstalled with fan trays and power supplies, contact marketing staff.
Figure2-3 LS-12500AI-6C-NCCA side panel
(1) Power supply latch |
(2) Mounting bracket installation position at the port side |
(3) Power supply handle |
LS-12500AI-96B-NCFK
Figure2-4 LS-12500AI-96B-NCFK front panel
(1) Copper management Ethernet port LED (ACT) |
(2) Copper management Ethernet port LED (LINK) |
(3) QSFP56 SFI port (96 in total) |
(4) QSFP56 SFI port LED |
(5) Location and system status LED (ID/SYS) |
(6) Power supply status LED (PSU) |
(7) Fan tray status LED (FAN) |
(8) SFP+ IPC port LED |
(9) SFP+ IPC port (2 in total) |
(10) Reset button (RESET) |
(11) Serial console port |
(12) USB port |
(13) Copper management Ethernet port |
Figure2-5 LS-12500AI-96B-NCFK rear panel
(1) Grounding point |
(2) Fan tray 1 |
(3) Fan tray 2 |
(4) Fan tray 3 |
(5) Fan tray 4 |
(6) Power supply 2 |
(7) Power supply 1 |
The LS-12500AI-96B-NCFK switch came with the two power supply slots empty. You can install one or two power supplies for the switch as needed. In Figure2-5, two PSR2000-12A-S AC power supplies are installed in the power supply slots.
The LS-12500AI-96B-NCFK switch came with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure2-5, four FAN-80B-1-D fan trays are installed in the fan tray slots.
The LS-12500AI-96B-NCFK switch supports shipping with fan trays and power supplies installed. To purchase a switch preinstalled with fan trays and power supplies, contact marketing staff.
Figure2-6 LS-12500AI-96B-NCFK side panel
(1) Power supply latch |
(2) Chassis rail installation position at the power supply side |
(3) Mounting bracket installation position at the port side |
(4) Power supply handle |
(5) Fan tray handle |
LS-12500AI-36B48B-NCPK
Figure2-7 LS-12500AI-36B48B-NCPK front panel
(1) Serial console port |
(2) SMB coaxial clock output port |
(3) SMB coaxial clock input port |
(4) 1PPS/TOD port |
(5) SFP HP-GE port LED (LINK/ACT) |
(6) SFP HP-GE port |
(7) Reset button (RESET) |
(8) QSFP56 service port (36 in total) |
(9) QSFP56 service port LED |
(10) QSFP56 SFI port (48 in total) |
(11) QSFP56 SFI port LED |
(12) Location and system status LED (ID/SYS) |
(13) Power supply status LED (PSU) |
(14) Fan tray status LED (FAN) |
(15) Copper management Ethernet port LED (ACT) |
(16) SFP+ IPC port LED |
(17) SFP+ IPC port (2 in total) |
(18) Copper management Ethernet port LED (LINK) |
(19) Copper management Ethernet port |
(20) USB port |
Figure2-8 LS-12500AI-36B48B-NCPK rear panel
(1) Grounding point |
(2) Serial label pull tab |
(3) Fan tray 1 |
(4) Fan tray 2 |
(5) Fan tray 3 |
(6) Fan tray 4 |
(7) Power supply 2 |
(8) Power supply 1 |
The LS-12500AI-36B48B-NCPK switch came with the two power supply slots empty. You can install one or two power supplies for the switch as needed. In Figure2-8, two PSR2000-12A-S AC power supplies are installed in the power supply slots.
The LS-12500AI-36B48B-NCPK switch came with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure2-8, four FAN-80B-1-D fan trays are installed in the fan tray slots.
The LS-12500AI-36B48B-NCPK switch supports shipping with fan trays and power supplies installed. To purchase a switch preinstalled with fan trays and power supplies, contact marketing staff.
Figure2-9 S12500AI-36B48B-NCPK side panel
(1) Power supply latch |
(2) Chassis rail installation position at the power supply side |
(3) Mounting bracket installation position at the port side |
(4) Power supply handle |
(5) Fan tray handle |
LS-12500AI-18D48B-NCPK
Figure2-10 LS-12500AI-18D48B-NCPK front panel
(1) Serial console port |
(2) SMB coaxial clock output port |
(3) SMB coaxial clock input port |
(4) 1PPS/TOD port |
(5) SFP HP-GE port LED (LINK/ACT) |
(6) SFP HP-GE port |
(7) Reset button (RESET) |
(8) QSFP-DD service port (18 in total) |
(9) QSFP-DD service port LED |
(10) QSFP56 SFI port (48 in total) |
(11) QSFP56 SFI port LED |
(12) Location and system status LED (ID/SYS) |
(13) Power supply status LED (PSU) |
(14) Fan tray status LED (FAN) |
(15) Copper management Ethernet port LED (ACT) |
(16) SFP+ IPC port LED |
(17) SFP+ IPC port (2 in total) |
(18) Copper management Ethernet port LED (LINK) |
(19) Copper management Ethernet port |
(20) USB port |
Figure2-11 LS-12500AI-18D48B-NCPK rear panel
(1) Grounding point |
(2) Serial label pull tab |
(3) Fan tray 1 |
(4) Fan tray 2 |
(5) Fan tray 3 |
(6) Fan tray 4 |
(7) Power supply 2 |
(8) Power supply 1 |
The LS-12500AI-18D48B-NCPK switch came with the two power supply slots empty. You can install one or two power supplies for the switch as needed. In Figure2-11, two PSR2000-12A-S AC power supplies are installed in the power supply slots.
The LS-12500AI-18D48B-NCPK switch came with the four fan tray slots empty. You must install four fan trays of the same model for the switch. In Figure2-11, four FAN-80B-1-D fan trays are installed in the fan tray slots.
The LS-12500AI-18D48B-NCPK switch supports shipping with fan trays and power supplies installed. To purchase a switch preinstalled with fan trays and power supplies, contact marketing staff.
Figure2-12 LS-12500AI-18D48B-NCPK side panel
(1) Power supply latch |
(2) Chassis rail installation position at the power supply side |
(3) Mounting bracket installation position at the port side |
(4) Power supply handle |
(5) Fan tray handle |
3 FRUs and compatibility matrixes
IMPORTANT: You must install power supplies of the same model on the switch. |
The switch uses modular design. Table3-1 describes the FRUs available for the switch.
Table3-1 FRUs and compatibility matrix
FRUs |
Product code |
LS-12500AI-6C-NCCA |
LS-12500AI-96B-NCFK |
LS-12500AI-36B48B-NCPK |
LS-12500AI-18D48B-NCPK |
Power supplies |
|||||
SW-A-PSR550-12A-B |
0231AKX6 |
Supported |
N/A |
N/A |
N/A |
SW-B-PSR550-12A-B |
0231AKX7 |
Supported |
N/A |
N/A |
N/A |
PSR2000-12A-S |
0231AMP2 |
N/A |
Supported |
Supported |
Supported |
PSR2000-12A-S-B |
0231AMNW |
N/A |
Supported |
Supported |
Supported |
Fan trays |
|||||
FAN-40B-1-C |
9803A00F |
Supported |
N/A |
N/A |
N/A |
FAN-80B-1-D |
0231AMNR |
N/A |
Supported |
Supported |
Supported |
One power supply can meet the power requirement of the switch. You can install two power supplies on the switch for 1+1 redundancy.
As a best practice to ensure adequate heat dissipation of the switch, fully configure the switch with fan trays of the same model.
4 Power supplies
CAUTION: When the switch has power supplies in 1+1 redundancy, you can replace a power supply without powering off the switch. Make sure the power supply to be replaced is powered off before you replace it. |
The switch uses removable power supplies. Select power supplies for the switch as required.
550W AC power supply (SW-A-PSR550-12A-B)
View
Figure4-1 SW-A-PSR550-12A-B power supply
(1) Status LED |
(2) Latch |
(3) AC-input power receptacle |
(4) Handle |
For the LED description, see "Status LED on a power supply."
Features
The SW-A-PSR550-12A-B is an AC or HVDC input and DC output power supply. It provides a maximum output of 550 W. Table4-1 describes the features provided by the SW-A-PSR550-12A-B power supply.
Table4-1 SW-A-PSR550-12A-B power supply features
Feature |
Description |
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
Support for hot swapping |
You can remove one of the power supplies in redundancy when the switch is operating. |
Technical specifications
Table4-2 Technical specifications
Item |
Specification |
Dimensions (H × W × D, including the handle) |
185 × 73.5 × 40 mm (7.28 × 2.89 × 1.57 in) |
Weight |
0.750 kg (1.65 lb) |
Rated AC input voltage range |
100 to 240 VAC @ 50 or 60 Hz |
Max AC input voltage range |
90 to 264 VAC |
Rated HVDC input voltage range |
240 VDC |
Max HVDC input voltage range |
190 to 310 VDC |
Rated input current |
7.0 A Max @ 100 to 240 VAC 3.5 A Max @ 240 VDC |
Rated output current |
45 A |
Rated output voltage |
12 V |
Rated output power |
550 W |
Melting current of power supply fuse |
10 A |
550W AC power supply (SW-B-PSR550-12A-B)
View
Figure4-2 SW-B-PSR550-12A-B power supply
For the LED description, see "Status LED on a power supply."
Features
The SW-B-PSR550-12A-B is an AC or HVDC input and DC output power supply. It provides a maximum output of 550 W. Table4-3 describes the features provided by the SW-A-PSR550-12A-B power supply.
Table4-3 SW-B-PSR550-12A-B power supply features
Feature |
Description |
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
Support for hot swapping |
You can remove one of the power supplies in redundancy when the switch is operating. |
Technical specifications
Table4-4 Technical specifications
Item |
Specification |
Dimensions (H × W × D, including the handle) |
185 × 73.5 × 40 mm (7.28 × 2.89 × 1.57 in) |
Weight |
0.775 kg (1.71 lb) |
Rated AC input voltage range |
100 to 240 VAC @ 50 or 60 Hz |
Max AC input voltage range |
90 to 264 VAC |
Rated HVDC input voltage range |
240 VDC |
Max HVDC input voltage range |
190 to 310 VDC |
Rated input current |
7.0 A Max @ 100 to 240 VAC 3.5 A Max @ 240 VDC |
Rated output current |
45 A |
Rated output voltage |
12 V |
Rated output power |
550 W |
Melting current of power supply fuse |
10 A |
2000W AC power supply (PSR2000-12A-S)
View
Figure4-3 PSR2000-12A-S power supply
For the LED description, see "Status LED on a power supply."
Features
The PSR2000-12A-S is an AC or HVDC input and DC output power supply. It provides a maximum output of 2000 W. Table4-5 describes the features provided by the PSR2000-12A-S power supply.
Table4-5 PSR2000-12A-S power supply features
Feature |
Description |
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
Support for hot swapping |
You can remove one of the power supplies in redundancy when the switch is operating. |
Technical specifications
Table4-6 Technical specifications
Item |
Specification |
Dimensions (H × W × D, including the handle) |
185 × 73.5 × 40 mm (7.28 × 2.89 × 1.57 in) |
Weight |
0.936 kg (2.06 lb) |
Rated AC input voltage range |
100 to 240 VAC @ 50 or 60 Hz |
Max AC input voltage range |
90 to 264 VAC |
Rated HVDC input voltage range |
270 VDC |
Max HVDC input voltage range |
180 to 320 VDC |
Rated input current |
12 A Max @ 100 to 127 VAC 10 A Max @ 200 to 240 VAC 10 A Max @ 270 VDC |
Rated output current |
164 A |
Rated output voltage |
12.2 V |
Rated output power |
2000 W |
Melting current of power supply fuse |
15 A |
2000W AC power supply (PSR2000-12A-S-B)
View
Figure4-4 PSR2000-12A-S-B power supply
For the LED description, see "Status LED on a power supply."
Features
The PSR2000-12A-S-B is an AC or HVDC input and DC output power supply. It provides a maximum output of 2000 W. Table4-7 describes the features provided by the PSR2000-12A-S-B power supply.
Table4-7 PSR2000-12A-S-B power supply features
Feature |
Description |
Protection function |
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output shortcircuit, and overtemperature conditions. |
Support for redundancy |
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing. |
Support for hot swapping |
You can remove one of the power supplies in redundancy when the switch is operating. |
Technical specifications
Table4-8 Technical specifications
Item |
Specification |
Dimensions (H × W × D, including the handle) |
185 × 73.5 × 40 mm (7.28 × 2.89 × 1.57 in) |
Weight |
0.945 kg (2.08 lb) |
Rated AC input voltage range |
100 to 240 VAC @ 50 or 60 Hz |
Max AC input voltage range |
90 to 264 VAC |
Rated HVDC input voltage range |
270 VDC |
Max HVDC input voltage range |
180 to 320 VDC |
Rated input current |
12 A Max @ 100 to 127 VAC 10 A Max @ 200 to 240 VAC 10 A Max @ 270 VDC |
Rated output current |
164 A |
Rated output voltage |
12.2 V |
Rated output power |
2000 W |
Melting current of power supply fuse |
15 A |
5 Fan trays
CAUTION: The switch has multiple fan tray slots. To ensure good ventilation of the switch, follow these guidelines to install and remove fan trays: · The switch came with the fan tray slots empty. As a best practice to ensure adequate heat dissipation, fully configure the switch with fan trays of the same model. Before you power on the switch, make sure the number of installed fan trays meets the minimum requirement. · Make sure each slot has a module or a filler panel installed while the switch is operating. · If multiple fan trays fail on an operating switch, do not remove the fan trays at the same time. Replace the fan trays one after another and finish replacing each fan tray within 3 minutes. |
FAN-40B-1-C
View
Figure5-1 FAN-40B-1-C fan tray
For the LED description, see "Fan tray alarm LED."
Features
The FAN-40B-1-C fan tray draws air from the port side to the power supply side. The fan tray is small, hot swappable, and can automatically adjust the fan speed according to the device temperature.
Technical specifications
Table5-1 Technical specifications
Item |
Specification |
Dimensions (H × W × D, including the handle) |
40 × 40 × 136 mm (1.57 × 1.57 × 5.35 in) |
Weight |
0.12 kg (0.26 lb) |
Airflow direction |
Air exhausted from the fan tray faceplate |
Max fan speed |
29000 R.P.M |
Max air flow rate |
38 CFM (1.08 m3/min) |
Input voltage |
12 V |
Max power consumption |
60 W |
FAN-80B-1-D
View
Figure5-2 FAN-80B-1-D fan tray
For the LED description, see "Fan tray alarm LED."
Features
The FAN-80B-1-D fan tray provides port-side intake and fan tray faceplate-side exhaust airflow. The fan tray is small, hot swappable, and can automatically adjust the fan speed according to the device temperature.
Technical specifications
Table5-2 Technical specifications
Item |
Specification |
Dimensions (H × W × D, including the handle) |
80 × 80 × 136 mm (3.15 × 3.15 × 5.35 in) |
Weight |
0.5 kg (1.10 lb) |
Airflow direction |
Air exhausted from the fan tray faceplate |
Max fan speed |
Inlet: 16000 R.P.M Outlet: 14000 R.P.M |
Max air flow rate |
163.92 CFM (4.64 m3/min) |
Input voltage |
12 V |
Max power consumption |
105.6 W |
6 Ports
As a best practice, use H3C modules and cables on the switch. The H3C modules and cables are subject to change over time. For the most recent list of H3C modules and cables, contact H3C Support or marketing staff. For more information about H3C transceiver modules and cables, see H3C Transceiver Modules User Guide.
Console port
The switch has one serial console port.
Table6-1 Console port specifications
Item |
Specification |
Connector type |
RJ-45 |
Compliant standard |
EIA/TIA-232 |
Operating mode |
Duplex Universal Asynchronous Receiver/Transmitter (UART) |
Transmission baud rate |
9600 bps (default) to 115200 bps |
Supported services |
· Provides connection to an ASCII terminal · Provides connection to the serial port of a local terminal (for example, a PC) running a terminal emulation program |
Management Ethernet port
The switch has one management Ethernet port. You can connect the port to a local PC for software loading and debugging or to a remote management station for remote management.
Table6-2 Management Ethernet port specifications
Item |
Specification |
Connector type |
RJ-45 |
Connector quantity |
1 |
Compliant standard |
IEEE802.3ab |
Transmission baud rate |
· 10 Mbps, full/half duplex · 100 Mbps, full/half duplex · 1000 Mbps, full duplex · MDI/MDI-X, auto-sensing |
Transmission medium and max transmission distance |
10/100/1000BASE-T management port: 100 m (328.08 ft) over a Category 5 unshielded twisted pair (UTP) |
Functions and services |
For device software upgrade and network management |
USB port
The switch has one OHCI-compliant USB 2.0 port that can upload and download data at a rate up to 480 Mbps. You can use this USB port to access the file system on the flash of the switch, for example, to upload or download application and configuration files.
The USB port supplies power as per USB 2.0 specifications. Use only USB 2.0-compliant USB devices for the USB port. The port might not identify USB devices that are not compliant with USB 2.0.
|
NOTE: USB devices from different vendors vary in compatibilities and drivers. H3C does not guarantee correct operation of USB devices from other vendors on the switch. If a USB device fails to operate on the switch, replace it with one from another vendor. |
SMB coaxial clock port
The LS-12500AI-6C-NCCA, LS-12500AI-36B48B-NCPK, and LS-12500AI-18D48B-NCPK switches each have one SMB coaxial clock input port and one SMB coaxial clock output port.
SMB coaxial clock ports provide input or output clock references at 2.048 Mbps (2.048 MHz). You can set the data rate mode or frequency mode from the CLI.
Table6-3 SMB coaxial clock port specifications
Item |
Specification |
Connector type |
SMB coaxial |
Description |
Sends and receives 2.048 MHz clock signals and 2.048 Mbps signals to synchronize the clocks of the switch and other devices |
Compliant standard |
GJB681 |
Transmission baud rate |
2.048 Mbps |
Transmission medium |
75-ohm coaxial cable |
1PPS/TOD port
The LS-12500AI-6C-NCCA, LS-12500AI-36B48B-NCPK, and LS-12500AI-18D48B-NCPK switches each have one 1PPS/TOD port.
Table6-4 1PPS/TOD port specifications
Item |
Specification |
Connector type |
RJ-45 |
Description |
Synchronizes the clocks of the switch and other devices |
Compliant standard |
QB-B-016-2010 |
SFP HP-GE port
The LS-12500AI-6C-NCCA, LS-12500AI-36B48B-NCPK, and LS-12500AI-18D48B-NCPK switches each have one SFP HP-GE port.
Table6-5 SFP HP-GE port specifications
Item |
Specification |
Port name |
1GE SFP HP-GE port |
Connector type |
LC |
Description |
Transmits and receives clock signals |
Compliant standard |
IEEE802.3ab |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
1000/100 Mbps autosensing, full duplex |
Available transceiver modules and cables |
· 1G SFP modules · 100M SFP modules |
SFP+ IPC port
The LS-12500AI-96B-NCFK, LS-12500AI-36B48B-NCPK, and LS-12500AI-18D48B-NCPK switches each have two SFP+ IPC ports.
Table6-6 SFP+ IPC port specifications
Item |
Specification |
Port name |
10GE SFP+ IPC port |
Connector type |
LC |
Description |
Transmits management packets in the Distributed Disaggregated Chassis (DDC) cloud cluster |
Compliant standard |
IEEE802.3ae |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
1000 Mbps/10 Gbps autosensing, full duplex |
Available transceiver modules and cables |
· 10G SFP+ modules · 10G SFP+ copper cables · 10G SFP+ AOC cables · 1G SFP modules |
SFP28 IPC port
The LS-12500AI-6C-NCCA switch has two SFP28 IPC ports.
Table6-7 SFP28 IPC port specifications
Item |
Specification |
Port name |
25GE/10GE SFP28 IPC port |
Connector type |
LC |
Description |
Transmits management packets in the DDC cloud cluster |
Compliant standard |
IEEE802.3by |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
Full duplex |
Available transceiver modules and cables |
· 25G SFP28 modules/cables · 10G SFP+ modules/cables · 1G SFP modules |
QSFP28 IPC port
The LS-12500AI-6C-NCCA switch has six QSFP28 IPC ports.
Table6-8 QSFP28 IPC port specifications
Item |
Specification |
Port name |
100GE/40GE QSFP28 fiber port |
Available switch models |
LS-12500AI-6C-NCCA |
Connector type |
LC/MPO |
Description |
Transmits management packets in the DDC cloud cluster |
Compliant standard |
IEEE802.3ba |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
Full duplex |
Available transceiver modules and cables |
· 100G QSFP28 modules · 100G QSFP28 copper cables · 100G QSFP28 AOC cables · 100G QSFP28 to 4 × 25G SFP28 copper cables · 40G QSFP+ modules · 40G QSFP+ copper cables · 40G QSFP+ AOC cables · 40G QSFP+ to 4 × 10G SFP+ copper cables |
QSFP56 SFI port
The LS-12500AI-96B-NCFK switch has 96 QSFP56 SFI ports.
The LS-12500AI-36B48B-NCPK and LS-12500AI-18D48B-NCPK switches each have 48 QSFP56 SFI ports.
Table6-9 QSFP56 SFI port specifications
Item |
Specification |
Port name |
200GE QSFP56 fiber port |
Connector type |
LC/MPO |
Description |
Connects an NCF and an NCP and switches cross-NCP service data |
Compliant standard |
IEEE 802.3cd |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
Full duplex |
Available transceiver modules and cables |
· 200G QSFP56 transceiver modules · 200G QSFP56 copper cables · 200G QSFP56 AOC cables |
QSFP56 service port
The LS-12500AI-36B48B-NCPK switch has 36 QSFP56 service ports.
Table6-10 QSFP56 service port specifications
Item |
Specification |
Port name |
200GE QSFP56 fiber port |
Connector type |
LC/MPO |
Description |
Connects to an external device and transmits and receives service packets |
Compliant standard |
IEEE 802.3cd |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
Full duplex |
Available transceiver modules and cables |
· 200G QSFP56 transceiver modules · 200G QSFP56 copper cables · 200G QSFP56 AOC cables |
QSFP-DD service port
The LS-12500AI-18D48B-NCPK switch has 18 QSFP-DD service ports.
Table6-11 QSFP-DD service port specifications
Item |
Specification |
Port name |
400GE QSFP-DD fiber port |
Connector type |
LC/MPO |
Description |
Connects to an external device and transmits and receives service packets |
Compliant standard |
IEEE 802.3bs |
Fiber port attribute |
Depends on the transceiver module or cable installed |
Operating mode |
Full duplex |
Available transceiver modules and cables |
· 400G QSFP-DD modules · 400G QSFP-DD copper cables · 400G QSFP-DD AOC cables |
7 LEDs
Location and system status LED
The location and system status LED shows the operating status of the switch and helps locate the switch in the equipment room. For how to use the LED to locate the switch, see the configuration guides and command references for the switch.
Table7-1 Location and system status LED description
LED mark |
Status |
Description |
ID/SYS |
Steady green |
The switch has started up correctly. |
Flashing green at 4 Hz |
The switch is performing power-on self test (POST) or loading software. |
|
Steady red |
The switch has failed POST or the switch is faulty. |
|
Steady yellow |
The following are the possible causes: · A fan tray has failed. · A power supply has failed. · The bus has failed. |
|
Flashing blue at 3 Hz |
Helps you locate the switch. |
|
Off |
The switch is powered off or has not started up correctly. |
Power supply status LED
The power supply status LED indicates the power supply operating status.
Table7-2 Power supply status LED description
LED mark |
Status |
Description |
PSU |
Off |
The switch is not powered on. |
Steady green |
Both power supplies are operating correctly. |
|
Steady yellow |
A power supply is faulty or not present. |
Fan tray status LED
The fan tray status LED indicates the fan tray operating status.
Table7-3 Fan tray status LED description
LED mark |
LED |
Description |
FAN |
Off |
The switch is not powered on. |
Steady green |
All present fan trays are operating correctly. |
|
Steady yellow |
A fan tray is operating incorrectly. |
|
Steady red |
More than one fan tray is operating incorrectly. |
Primary/backup status LED
The primary/backup status LED indicates the primary or backup state of the switch.
Table7-4 Primary/backup status LED description
LED mark |
LED |
Description |
ACT |
Steady green |
The switch is in primary state. |
Off |
The switch is in backup state. |
SFP HP-GE port LED
Table7-5 SFP HP-GE port LED description
LED status |
Description |
Steady green |
A module has been installed and a link is present on the port. |
Flashing green |
The port is receiving or sending data. |
Off |
No module has been installed or no link is present on the port. |
SFP+ IPC port LED
Table7-6 SFP+ IPC port LED description
LED status |
Description |
Steady green |
A module has been installed and a link is present on the port. |
Flashing green |
The port is receiving or sending data. |
Off |
No module has been installed or no link is present on the port. |
SFP28 IPC port LED
Table7-7 SFP28 IPC port LED description
LED status |
Description |
Steady green |
A module has been installed and a link is present on the port. |
Flashing green |
The port is receiving or sending data. |
Off |
No module has been installed or no link is present on the port. |
QSFP28 IPC port LED
Table7-8 QSFP28 IPC port LED description
LED status |
Description |
Steady green |
A module has been installed and a link is present on the port. |
Flashing green |
The port is receiving or sending data. |
Off |
No module has been installed or no link is present on the port. |
QSFP56 SFI port LED
Table7-9 QSFP56 SFI port LED description
LED status |
Description |
Steady green |
A module has been installed and the four lanes each have a link. |
Steady yellow |
A module has been installed and one to three lanes each have a link. |
Off |
No module has been installed or no lane has a link. |
QSFP56 service port LED
Table7-10 QSFP56 service port LED description
LED status |
Description |
Steady green |
A module has been installed and a link is present on the port. |
Flashing green |
The port is receiving or sending data. |
Off |
No module has been installed or no link is present on the port. |
QSFP-DD service port LED
Table7-11 QSFP-DD service port LED description
LED status |
Description |
Steady green |
A module has been installed in the port. A link is present on the port and the port is operating at its maximum speed of 400 Gbps. |
Flashing green |
The port is receiving or sending data at its maximum speed of 400 Gbps. |
Off |
No module has been installed or no link is present on the port. |
Management Ethernet port LED
The switch provides two status LEDs (LINK and ACT) for the copper management Ethernet port. The management Ethernet port LEDs indicate the operating status of the management Ethernet port.
Table7-12 Management Ethernet port LED description
LED mark |
Status |
Description |
LINK |
Off |
No link is present on the management Ethernet port. |
Steady green |
The management Ethernet port is operating at 10/100/1000 Mbps. |
|
ACT |
Off |
The management Ethernet port is not receiving or sending data. |
Flashing yellow |
The management Ethernet port is receiving or sending data. |
Status LED on a power supply
The power supplies each have a status LED to indicate the power input and output status.
Status LED on an SW-A-PSR550-12A-B/SW-B-PSR550-12A-B power supply
Table7-13 Description for the status LED on an SW-A-PSR550-12A-B/SW-B-PSR550-12A-B power supply
LED status |
Description |
Steady green |
The power supply is operating correctly. |
Flashing green at 1 Hz |
Power is being input correctly but the system is not powered on. |
Flashing green at 0.33 Hz |
The power supply is in standby state and is not outputting power. |
Flashing green at 2 Hz |
The power supply is updating its firmware. |
Steady amber |
· The power supply has failed. · The power supply does not have power input, but the other power supply has correct power input. |
Flashing amber at 1 Hz |
An alarm has occurred on the power supply. |
Off |
No power input, which can be caused by an incorrect power cord connection or power source shutdown. |
Status LED on a PSR2000-12A-S/PSR2000-12A-S-B power supply
Table7-14 Description for the status LED on a PSR2000-12A-S/PSR2000-12A-S-B power supply
LED status |
Description |
Steady green |
The power supply is operating correctly and is in active state. |
Flashing green at 1 Hz |
The power supply is operating correctly and is in standby state. |
Flashing green at 2 Hz |
The power supply is updating the software. |
Steady amber |
The power supply has failed or has entered a protection state. |
Flashing amber at 1 Hz |
An alarm has occurred because one of the following conditions exists on the power supply but the power supply does not enter protection state: · Output overvoltage. · Output undervoltage. · Output overcurrent. · Output power overload. · Overtemperature. |
Flashing amber at 2 Hz |
The power supply does not have power input but the power supply working in parallel with it has power input. |
Off |
Neither this power supply nor the power supply working in parallel with it has power input. |
Fan tray alarm LED
The fan trays each have an alarm LED to indicate the operating status.
Table7-15 Description for the alarm LED on a fan tray
LED status |
Description |
Steady green |
The fan tray is operating correctly. |
Steady red |
The fan tray is operating incorrectly. |
Off |
The fan tray is operating incorrectly or not powered on. |
8 Cooling system
CAUTION: The chassis and power supplies use separate air aisles. Make sure the two aisles are not blocked when the switch is operating. |
To dissipate heat timely and enhance system stability, the switch uses a high-performance cooling system with a front-rear air aisle. Consider the site ventilation design when you plan the installation site for the switch.
Table8-1 Cooling system
Switch model |
Available fan trays |
Airflow direction |
LS-12500AI-6C-NCCA |
FAN-40B-1-C |
From the port side to the power supply side |
LS-12500AI-96B-NCFK |
FAN-80B-1-D |
From the port side to the power supply side |
LS-12500AI-36B48B-NCPK |
FAN-80B-1-D |
From the port side to the power supply side |
LS-12500AI-18D48B-NCPK |
FAN-80B-1-D |
From the port side to the power supply side |