- Table of Contents
- Related Documents
-
| Title | Size | Download |
|---|---|---|
| 01-HH3C-LswMix-MIB | 85.96 KB |
Contents
hh3cLswLastSwitchDate (1.3.6.1.4.1.25506.8.35.17.1)
hh3cLswLastSwitchTime (1.3.6.1.4.1.25506.8.35.17.2)
hh3cLswMpuSwitchsNum (1.3.6.1.4.1.25506.8.35.17.3)
hh3cLswMpuSwitch (1.3.6.1.4.1.25506.8.35.17.4)
HH3C-LswMix-MIB
About this MIB
Use this MIB to obtain information about slot roles in an IRF fabric, trigger an active/standby or master/subordinate switchover, and obtain information about switchover records.
MIB file name
hh3c-splat-mix.mib
Root object
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).hh3c(25506).hh3cRhw(8).hh3clswCommon(35).hh3cLswMix(17)
Scalar objects
hh3cLswLastSwitchDate (1.3.6.1.4.1.25506.8.35.17.1)
|
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
|
hh3cLswLastSwitchDate (1.3.6.1.4.1.25506.8.35.17.1) |
read-only |
Integer32 |
Standard MIB values. |
Date on which the last active/standby or master/subordinate switchover occurred. |
The read operation is not supported on a non-default MDC. |
hh3cLswLastSwitchTime (1.3.6.1.4.1.25506.8.35.17.2)
|
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
|
hh3cLswLastSwitchTime (1.3.6.1.4.1.25506.8.35.17.2) |
read-only |
Integer32 |
Standard MIB values. |
Time when the last active/standby or master/subordinate switchover occurred. |
The read operation is not supported on a non-default MDC. |
hh3cLswMpuSwitchsNum (1.3.6.1.4.1.25506.8.35.17.3)
|
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
|
hh3cLswMpuSwitchsNum (1.3.6.1.4.1.25506.8.35.17.3) |
read-only |
Integer32 |
Standard MIB values. |
Number of times active/standby or master/subordinate switchovers occurred. |
The read operation is not supported on a non-default MDC. |
hh3cLswMpuSwitch (1.3.6.1.4.1.25506.8.35.17.4)
|
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
|
hh3cLswMpuSwitch (1.3.6.1.4.1.25506.8.35.17.4) |
read-write |
INTEGER |
switch(1) |
This object triggers an active/standby or master/subordinate switchover. |
The read operation is not supported. |
Tabular objects
hh3cLswXSlotTable
About this table
Use this table to obtain slot role information in an IRF fabric. For modular devices, a slot refers to an MPU or an interface module. For fix-port devices or expandable fixed-port devices, a slot refers to an IRF member device.
Support for operations
Create:Not supported
Edit/Modify:Not supported
Delete:Not supported
Read:Supported
Columns
The table indexes are hh3cLswFrameIndex and hh3cLswSlotIndex.
|
Object (OID) |
Access |
Syntax |
Value range |
Description |
Implementation |
|
hh3cLswMainCardBoardStatus (1.3.6.1.4.1.25506.8.35.17.5.1.1) |
read-only |
INTEGER |
master(1), |
Role of a slot in an IRF fabric. |
As per the MIB. |
|
hh3cLswCrossBarStatus (1.3.6.1.4.1.25506.8.35.17.5.1.2) |
read-only |
INTEGER |
master(1), |
Cross bar role of the slot. |
Not supported. |
Notifications
hh3cSlaveSwitchOver
Basic information
|
OID |
Event |
Type |
Severity |
Recovery notification |
Default status |
|
1.3.6.1.4.1.25506.8.35.17.10.1 |
An active/standby or master/subordinate switchover occurred. |
Informational |
Minor |
N/A (N/A) |
ON |
Notification triggers
(Centralized IRF devices.) This notification is generated upon a master/subordinate switchover in an IRF fabric.
(Distributed devices.) This notification is generated upon an active/standby or master/subordinate switchover.
System impact
No impact on services.
Status control
This notification cannot be disabled.
Object
|
OID (object name) |
Description |
Index |
Type |
Value range |
|
无 (无) |
无 |
无 |
无 |
无 |
Recommended action
1.Locate the issue and handle it accordingly.
- No action is required if the switchover was performed manually.
- If the switchover was caused by an exceptional event, you must examine the device running conditions to troubleshoot the issue.
2.If the issue persists, contact H3C Support.