H3C MSR Router Series Interface Module Guide-6W131

HomeSupportProduct LiteratureHardware Information & SpecificationsH3C MSR Router Series Interface Module Guide-6W131
01-Text
Title Size Download
01-Text 12.72 MB

Contents

SIC/DSIC interface modules· 1

Ethernet switching modules· 1

SIC-4FSW/SIC-4FSWP/DSIC-9FSW/DSIC-9FSWP· 1

SIC-4GSW·· 3

RT-SIC-4GSWF· 4

Ethernet interface modules· 5

SIC-1FEA· 5

SIC-1FEF· 6

RT-SIC-4GSW-G·· 7

RT-SIC-4GSWF-G·· 8

SIC-1GEC-V2· 9

RT-SIC-1XPF-G·· 11

POS (SDH/SONET) interface modules· 12

RT-SIC-1POS-STM1· 12

E1/T1 interface modules· 13

SIC-E1-F· 13

SIC-2E1-F· 14

RT-SIC-2E1-G·· 15

SIC-1EPRI 17

SIC-T1-F· 18

Serial interface modules· 19

SIC-8AS· 20

SIC-16AS· 21

SIC-1SAE/SIC-2SAE/SIC-4SAE· 22

SIC-4RS· 23

Analog modem interface modules· 27

SIC-1AM/SIC-2AM·· 27

XDSL interface modules· 28

SIC-1ADSL· 28

SIC-1ADSL-I 30

ISDN BRI interface modules· 31

SIC-1BS/SIC-2BS· 31

Voice interface modules· 32

SIC-1FXS/SIC-1FXO/SIC-2FXS/SIC-2FXO·· 33

SIC-2FXS1FXO·· 34

DSIC-4FXS1FXO·· 35

SIC-1BSV/SIC-2BSV· 36

SIC-1VE1· 38

SIC-1VT1· 39

SIC-1VE1T1· 40

3G interface modules· 41

SIC-3G-CDMA· 41

SIC-3G-TD·· 43

SIC-3G-HSPA· 44

4G interface modules· 46

SIC-4G-LTE-M·· 46

SIC-4G-CNDE· 48

RT-SIC-4G-CAT6· 50

SIC-D4G-CNDE· 53

5G interface modules· 55

RT-SIC-5G·· 55

RT-SIC-5G-CN· 58

Network data encryption modules· 61

SIC-CNDE· 61

SIC-CNDE-SJK· 62

SIC-4G-CNDE-SJK· 62

SIC-D4G-CNDE-SJK· 64

WLAN interface modules· 67

SIC-AP220· 67

SIC-AP320· 68

M.2 riser SIC modules· 69

RT-SIC-M2-SATA· 69

MIM interface modules· 72

ATM interface modules· 72

MIM-1ATM-OC3· 72

POS (SDH/SONET) interface modules· 73

MIM-1POS· 73

E1/T1 interface modules· 74

MIM-1E1/MIM-2E1/MIM-4E1/MIM-1E1-F/MIM-2E1-F/MIM-4E1-F· 74

MIM-8E1/MIM-8E1-F· 76

MIM-2T1/MIM-4T1-F· 77

E3/T3 interface modules· 78

MIM-1CE3· 78

Serial interface modules· 79

MIM-2SAE/MIM-4SAE/MIM-8SAE· 80

MIM-8ASE/MIM-16ASE· 81

POS terminal access interface modules· 82

MIM-6FCM·· 82

Voice interface modules· 84

MIM-8FXS8FXO·· 84

MIM-16FXS· 85

MIM-2VE1· 86

MIM-2VT1· 87

MIM-1VE1· 88

MIM-1VT1· 89

MIM-4FXS/MIM-4FXO·· 90

MIM-4E&M·· 91

HMIM/DHMIM interface modules· 93

Ethernet switching modules· 93

HMIM-8GSW/HMIM-24GSW/HMIM-24GSW-PoE· 93

HMIM-8GSWF· 95

Ethernet interface modules· 96

HMIM-2GEE/HMIM-4GEE/HMIM-8GEE· 96

RT-HMIM-4GEE-V2/RT-HMIM-8GEE-V2· 97

RT-HMIM-4GEE-V2-G/RT-HMIM-8GEE-V2-G·· 99

HMIM-2GEF/HMIM-4GEF/HMIM-8GEF· 100

RT-HMIM-4GEF-V2/RT-HMIM-8GEF-V2· 101

RT-HMIM-4XP· 103

ATM interface modules· 104

HMIM-1ATM-OC3· 104

POS (SDH/SONET) interface modules· 105

HMIM-1POS· 105

RT-HMIM-2POS-STM1· 106

RT-HMIM-4POS-STM1/4· 107

CPOS (SDH/SONET) interface modules· 108

HMIM-1CPOS/HMIM-2CPOS· 108

E1/T1 interface modules· 110

HMIM-1E1/HMIM-2E1/HMIM-4E1/HMIM-1E1-F/HMIM-2E1-F/HMIM-4E1-F· 110

HMIM-8E1(75)/HMIM-8E1-F(75) 112

RT-HMIM-2E1-V3/RT-HMIM-4E1-V3/RT-HMIM-8E1-V3· 113

HMIM-2T1/HMIM-4T1-F· 117

HMIM-2E1T1/HMIM-4E1T1/HMIM-8E1T1/HMIM-2E1T1-F/HMIM-4E1T1-F/HMIM-8E1T1-F· 118

E3/T3 interface modules· 121

HMIM-1CE3· 121

Serial interface modules· 122

HMIM-2SAE/HMIM-4SAE/HMIM-8SAE· 123

RT-HMIM-4SAE-V2/RT-HMIM-8SAE-V2· 124

HMIM-8ASE/HMIM-16ASE· 126

RT-HMIM-8ASE-V2/RT-HMIM-16ASE-V2· 127

POS terminal access interface modules· 128

HMIM-1E1POS· 128

DHMIM-1E1POS1DM·· 130

Digital modem interface modules· 131

DHMIM-1DM·· 131

Voice interface modules· 133

HMIM-16FXS· 133

HMIM-8FXS8FXO·· 134

HMIM-2VE1· 135

HMIM-2VT1· 136

HMIM-1VE1· 137

HMIM-1VT1· 138

HMIM-4FXS/HMIM-4FXO·· 139

HMIM-4E&M/HMIM-8E&M·· 140

Analog modem modules· 141

HMIM-6AM·· 141

HMIM-6FCM·· 142

Network data encryption modules· 143

HMIM-CNDE-SJK· 143

HMIM adapters· 143

HMIM-Adapter/HMIM-Adapter-H· 143

VPM modules· 145

VPM purchase guide· 145

Introduction· 145

Interface specifications· 145

XMIM interface modules· 145

Ethernet interface modules· 146

RT-XMIM-8GEE-R· 146

RT-XMIM-8GEF-R· 147

RT-XMIM-4XP· 148

POS (SDH/SONET) interface modules· 150

RT-XMIM-1POS/RT-XMIM-2POS· 150

CPOS (SDH/SONET) interface modules· 151

RT-XMIM-1CPOS· 151

E1 interface modules· 152

RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1· 153

Network data encryption modules· 156

RT-XMIM-CNDE-SJK· 156

SSD modules· 157

RT-SSD-960G·· 157

Cables and the connection methods· 158

Ethernet interface· 158

Fiber port 160

E1 interface· 160

T1 interface· 168

E3/T3 interface· 169

Synchronous/asynchronous serial ports· 170

Asynchronous serial ports· 172

ADSL/BS/FXS/FXO/AM/FCM interface· 177

E&M interface· 178

BSV/BSE interface· 179

3G interface· 181

4G interface· 182

5G interface· 186

GPS interface· 190

GNSS interface· 191

WLAN interface· 192

Link mode of interfaces on Ethernet switching modules and interface modules  193

Frequency bands for 3G/4G/5G interface modules· 195

Interface module net weights and power consumption· 197

 


SIC/DSIC interface modules

CAUTION

CAUTION:

·     You can hot swap or perform an online removal and insertion (OIR) operation on an interface module. OIR requires you to execute the remove command or press the REMOVE button before you remove an interface module, and hot swapping does not.

·     Only the RT-SIC-4GSW-G, RT-SIC-4GSWF-G, and RT-SIC-2E1-G interface modules support hot swapping.

·     SIC interface modules with a remove button support OIR. To remove a SIC interface module with a remove button while the device is operating, first press the remove button or execute the remove command. For the specific operation instructions, see the description for the SIC interface module. The remove command and the remove button cannot be used simultaneously, as this might cause the SIC interface module to become unusable.

·     The SIC interface modules, except for the RT-SIC-4GSW-G, RT-SIC-2E1-G, and those with a remove button, do not support hot swapping or OIR.

·     DSIC interface modules cannot be hot-swapped.

 

MSR series routers use modular design and support a wide range of optional smart interface cards (SICs) and double smart interface cards (DSICs). A SIC occupies one SIC slot and a DSIC occupies two SIC slots. The SIC/DSIC series interface modules provide abundant interfaces, including synchronous/asynchronous serial interface, Ethernet interface, E1/T1, ISDN BRI/PRI, ADSL, audio interface, and Layer 2 switching interface.

Ethernet switching modules

·     SIC-4FSW

·     SIC-4FSWP

·     DSIC-9FSW

·     DSIC-9FSWP

·     SIC-4GSW

·     RT-SIC-4GSWF

SIC-4FSW/SIC-4FSWP/DSIC-9FSW/DSIC-9FSWP

Introduction

The SIC-4FSW/SIC-4FSWP and DSIC-9FSW/DSIC-9FSWP interface modules are 4/9-port 10/100 Mbps Ethernet Layer 2 SIC interface modules that can be used on H3C MSR series routers. They provide up to 4/9 10/100 BASE-Tx Ethernet ports for Layer 2 and Layer 3 switching. A router installed with SIC-4FSW/SIC-4FSWP and DSIC-9FSW/DSIC-9FSWP modules can work as a switching/routing integrated device on a small-sized enterprise network to connect PCs and network devices inside the network directly. SIC-4FSWP/DSIC-9FSWP interface modules can supply power to powered devices (PDs) through power over Ethernet (PoE).

Functions supported by interface modules are as follows:

·     Effective transmission distance of 100 m (328.08 ft) with category-5 twisted pair cables (both crossover and straight-through)

·     Effective transmission distance of 100 m (328.08 ft) between any interfaces with category-5 twisted pair cables (both crossover and straight-through)

·     Operating speeds of both 100 Mbps and 10 Mbps and autosensing

·     Both full duplex (in common use) and half-duplex operating modes

Interface specifications

Table 1 describes the interface specifications of the SIC-4FSW, SIC-4FSWP, DSIC-9FSW, and DSIC-9FSWP interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 1 Interface specifications

Item

SIC-4FSW/SIC-4FSWP

DSIC-9FSW/DSIC-9FSWP

Connector

RJ-45

Interface type

MDI/MDIX

Number of connectors

Four 100 Mbps RJ-45 connectors

Nine 100 Mbps RJ-45 connectors

Cable

Standard (straight-through)/cross-over Ethernet cable

Operation mode

10/100 Mbps autosensing, full/half duplex

 

 

NOTE:

Ethernet interfaces on network adapters are usually medium dependent interfaces (MDIs). Medium dependent interfaces crossover (MDIXs) are another type of Ethernet interfaces, which are usually used on hubs and LAN switches.

 

Interface LEDs

Figure 1 SIC-4FSW panel

SIC-4FSW

 

Figure 2 SIC-4FSWP panel

SIC-4FSW-POE

 

Figure 3 DSIC-9FSW panel

DSIC-9FSW+口

 

Figure 4 DSIC-9FSWP panel

DSIC-9FSW-POE+口

 

On the panel, each port corresponds to one green LED. The following table describes the LEDs on the panel.

Table 2 LED description

Status

Description

Steady on

A link is present, but no data is being transmitted or received.

Off

No link is present.

Flashing

A link is present and data is being transmitted and received (ACT).

 

In addition, there is a PoE LED on each module, which is provided for the corresponding modules (SIC-4FSWP and DSIC-9FSWP) with the PoE function.

Interface cables and the connection methods

For more information about Ethernet interface cables and the connection methods, see "Ethernet interface."

SIC-4GSW

Introduction

The SIC-4GSW interface module is a 4-port 1000 Mbps Ethernet Layer 2 SIC interface module. The SIC-4GSW provides four 1000 Mbps RJ-45 ports. A router installed with SIC-4GSW modules can operate as a switching/routing integrated device on a small-sized enterprise network to connect PCs and network devices inside the network directly.

Functions supported by interface modules are as follows:

·     Effective transmission distance of 100 m (328.08 ft) over category-5 twisted pair cables (both crossover and straight-through)

·     Line rate of 1000 Mbps between any interfaces over category-5e twisted pair cables (both crossover and straight-through)

·     Autosensing operating speeds of 1000 Mbps, 100 Mbps, and 10 Mbps

·     Both full duplex (typically used) and half-duplex operating modes

Interface specifications

Table 3 describes the interface specifications of the SIC-4GSW interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 3 Interface specifications

Item

Description

Connector

RJ-45

Interface type

MDI/MDIX

Number of connectors

4

Cable

Standard (straight-through)/cross-over Ethernet cable

Operation mode

10/100/1000 Mbps autosensing

 

 

NOTE:

Ethernet interfaces on network adapters are usually medium dependent interfaces (MDIs). Medium dependent interfaces crossover (MDIXs) are another type of Ethernet interfaces, which are usually used on hubs and LAN switches.

 

Interface LEDs

Figure 5 SIC-4GSW panel

 

The SIC-4GSW interface module provides a double-color (green/yellow) LED for each port to indicate the operating status of the port.

Table 4 LED description

Status

Description

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is sending and receiving data at 10/100 Mbps.

 

Interface cables and the connection methods

For information about Ethernet interface cables and the connection methods, see "Ethernet interface."

RT-SIC-4GSWF

Introduction

The 4-port 100/1000 Mbps Ethernet Layer 2/Layer 3 SIC interface module RT-SIC-4GSWF provides four fiber ports. It is designed for switching/routing integrated routers on a small-sized enterprise network. You can use it to connect network devices inside the network.

The interface module has the following features:

·     Support for multiple 100/1000 Mbps transceiver modules.

·     1000/100 Mbps interface rate.

·     Full duplex operating mode.

Interface specifications

Table 5 describes the interface specifications of the RT-SIC-4GSWF interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 5 Interface specifications

Item

Description

Number of interfaces

4

Connector

SFP/LC

Standard

802.3/802.3u/802.3ab

Operating mode

1000/100 Mbps, full duplex

 

Interface LEDs

Figure 6 RT-SIC-4GSWF panel

 

The RT-SIC-4GSWF interface module provides a double-color (green/yellow) LED for each port to indicate the operating status of the port.

Table 6 LED description

Status

Description

Off

No link is present.

Steady green

A link is present on the port and the port is operating at 1000 Mbps.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Steady yellow

A link is present on the port and the port is operating at 100 Mbps.

Flashing yellow

The port is sending and receiving data at 100 Mbps.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and connection methods, see "Fiber port."

Ethernet interface modules

·     SIC-1FEA

·     SIC-1FEF

·     RT-SIC-4GSW-G

·     RT-SIC-4GSWF-G

·     SIC-1GEC-V2

·     RT-SIC-1XPF-G

SIC-1FEA

Introduction

The 1-port 10BASE-T/100BASE-TX Ethernet interface module (SIC-1FEA) is used for communication between the router and LAN. It supports:

·     Effective transmission distance of 100 m (328.08 ft) with category-5 twisted pair cables

·     Operating speeds of both 100 Mbps and 10 Mbps and autosensing

·     Both full duplex (in common use) and half-duplex operating modes

Interface specifications

Table 7 describes the interface specifications of the SIC-1FEA interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 7 Interface specifications

Item

Description

Connector type

RJ-45

Interface type

MDI

Number of connectors

1

Cable type

Straight-through Ethernet cable

Operating mode

10/100 Mbps autosensing

Full duplex/half duplex

 

 

NOTE:

Ethernet interfaces on network adapters are usually medium dependent interfaces (MDIs). Medium dependent interfaces crossover (MDIXs) are another type of Ethernet interfaces, which are usually used on hubs and LAN switches.

 

Interface LEDs

Figure 7 SIC-1FEA panel

SIC-1FEA

 

Table 8 LED description

LED

Description

LINK

·     Off: No link is present;

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received;

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about the Ethernet interface cables and the connection methods, see "Ethernet interface".

SIC-1FEF

Introduction

The 1-port 100 Mbps fiber Ethernet interface module (SIC-1FEF) is used for the communication between the router and LAN.

SIC-1FEF supports:

·     Various types of transceiver modules.

·     100 Mbps interface rate.

·     Full duplex.

Interface specifications

Table 9 describes the interface specifications of the SIC-1FEF interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 9 Interface specifications

Item

Description

Number of interfaces

1

Connector

SFP/LC

Interface standard

802.3, 802.3u, and 802.3ab

Operating mode

100 Mbps

Full duplex

 

Interface LEDs

Figure 8 SIC-1FEF panel

SIC-1FEF

 

Table 10 LED description

LED

Status

Description

LINK/ACT

Off

No link is present.

Steady green

The optical module has established a 100 Mbps link.

Flashing green

Data is being received and transmitted.

Steady yellow

Information detection failed.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and connection methods, see "Fiber port."

RT-SIC-4GSW-G

Introduction

The 4-port 1000 Mbps Ethernet SIC interface module RT-SIC-4GSW-G provides four 1000 Mbps RJ-45 ports and is used for communication between the router and LAN.

The interface module has the following features:

·     Effective transmission distance of 100 m (328.08 ft) over category-5 twisted pair cables (both crossover and straight-through).

·     Line rate of 1000 Mbps between any interfaces over category-5e twisted pair cables (both crossover and straight-through).

·     Autosensing operating speeds of 1000 Mbps, 100 Mbps, and 10 Mbps.

·     Both full duplex (typically used) and half-duplex operating modes

Interface specifications

Table 11 describes the interface specifications of the RT-SIC-4GSW-G interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 11 Interface specifications

Item

Description

Connector

RJ-45

Interface type

MDI/MDIX

Number of connectors

4

Cable

Standard (straight-through)/crossover Ethernet cable

Operating mode

10/100/1000 Mbps autosensing

 

 

NOTE:

Ethernet interfaces on network adapters are usually medium dependent interfaces (MDIs). Medium dependent interfaces crossover (MDIXs) are another type of Ethernet interfaces, which are usually used on hubs and LAN switches.

 

Interface LEDs

Figure 9 RT-SIC-4GSW-G panel

 

On the panel, each port corresponds to one green LED and one yellow LED.

Table 12 LED description

LED

Status

Description

LINK/ACT

Steady green

A link is present on the port and the port is operating at 1000 Mbps.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Steady yellow

A link is present on the port and the port is operating at 10/100 Mbps.

Flashing yellow

The port is sending and receiving data at 10/100 Mbps.

Off

No link is present.

 

Interface cables and the connection methods

For information about Ethernet interface cables and the connection methods, see "Ethernet interface."

RT-SIC-4GSWF-G

Introduction

The 4-port 100/1000 Mbps Ethernet Layer 3 SIC interface module RT-SIC-4GSWF-G provides four SFP fiber ports and is used for communication between the router and LAN. It supports:

·     Various types of FE and GE transceiver modules.

·     100/1000 Mbps interface rate.

·     Full duplex.

Interface specifications

Table 13 describes the interface specifications of the RT-SIC-4GSWF-G interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 13 Interface specifications

Item

Description

Number of interfaces

4

Connector

SFP/LC

Interface standard

802.3, 802.3u, 802.3ab

Operating mode

100/1000 Mbps

Full duplex

 

Interface LEDs

Figure 10 RT-SIC-4GSWF-G panel

 

The RT-SIC-4GSWF-G interface module provides a double-color (green/yellow) LED for each port to indicate the operating status of the port.

Table 14 LED description

LED

Status

Description

LINK/ACT

Steady green

A link is present on the port and the port is operating at 1000 Mbps.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Steady yellow

A link is present on the port and the port is operating at 100 Mbps.

Flashing yellow

The port is sending and receiving data at 100 Mbps.

Off

No link is present.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and connection methods, see "Fiber port."

SIC-1GEC-V2

Introduction

The 1-port 10/100/1000 Mbps electrical and fiber Ethernet interface SIC module (SIC-1GEC-V2) has the following functions:

·     Receipt, transmission and processing of GE data stream

·     CE electrical and fiber port access

·     1000/100/10 Mbps on copper port

·     1000 Mbps on fiber port

Interface specifications

Table 15 describes the interface specifications of the SIC-1GEC-V2 interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 15 Interface specifications

Item

Description

Connector

RJ-45

Interface type

MDI

Frame format

·     Ethernet_II

·     Ethernet_SNAP

·     IEEE 802.2

·     IEEE 802.3

Operation mode

10/100/1000 Mbps autosensing

Full/half duplex

 

 

NOTE:

The SIC-1GEC-V2 provides combo interfaces. The fiber and copper ports of a combo interface cannot be used simultaneously. By default, the copper port is available. To use the fiber port, execute the related command.

 

Interface LEDs

Figure 11 SIC-1GEC-V2 panel

 

Table 16 LED description for the copper port on the SIC-1GEC-V2 panel

LED

Description

LINK

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Green: Data is being received and transmitted at a speed of 1000 Mbps.

·     Yellow: Data is being received and transmitted at a speed of 100/10 Mbps.

ACT

·     Off: No data is being received and transmitted;

·     Flashing: Data is being received and transmitted.

 

Table 17 LED description for the fiber port on the SIC-1GEC-V2 panel

LED

Description

LINK

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Green: Data is being received and transmitted at a speed of 1000 Mbps.

·     Yellow: Fault.

ACT

·     Off: No data is being received and transmitted.

·     Flashing: Data is being received and transmitted.

 

Interface cables and the connection methods

For information about Ethernet interface cables and the connection methods, see "Ethernet interface."

For information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

RT-SIC-1XPF-G

CAUTION

CAUTION:

The RT-SIC-1XPF-G interface module is hot swappable. To remove an RT-SIC-1XPF-G interface module, first press and hold the remove button for a minimum of 3 seconds. You can remove the interface module only when the remove LED is turned off. If the remove LED is flashing green, wait for the remove LED to turn off and then remove the interface module.

 

Introduction

The 10 Gbps Ethernet interface module RT-SIC-1XPF-G provides one SFP+ fiber port, which is a Layer 3 service port. The interface module supports port type switching between standard Ethernet and FlexE. The FlexE mode allows flexible bandwidth assignment to meet different service requirements.

Interface specifications

Table 18 describes the interface specifications of the RT-SIC-1XPF-G interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 18 Interface specifications

Item

Description

Number of interfaces

1

Connector

SFP+/LC

Interface standard

10GBASE-R

Operating mode

10 Gbps, full duplex

 

Panel and interface LEDs

Figure 12 RT-SIC-1XPF-G panel

 

Table 19 LED description

LED

Status

Description

LINK/ACT

Steady green

A link is present on the port and the port is operating at 10 Gbps.

Flashing green

The port is sending and receiving data at 10 Gbps.

Off

No link is present.

REMOVE

Steady green

The module is operating correctly. You can press the remove button to remove the module.

Flashing green

·     The module is initializing. You cannot press the remove button or remove the module.

·     The module is being removed.

Off

You can remove the module if all the other LEDs on the module are also off.

 

CAUTION

CAUTION:

During online upgrade of the RT-SIC-1XPF-G interface module, do not remove it. In the upgrade process, the remove LED flashes green, turns off, flashes again, and then remains steady on.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and connection methods, see "Fiber port."

POS (SDH/SONET) interface modules

RT-SIC-1POS-STM1

Introduction

The RT-SIC-1POS-STM1 1-port SDH/SONET interface module provides an interface transmission rate of 155.52 Mbps (STM-1/OC-3).

The RT-SIC-1POS-STM1 supports PPP, Frame Relay, and HDLC protocols at the data link layer and the IP protocol at the network layer. It allows direct transmission of packets over SONET/SDH. It provides a 155.52 Mbps fractional interface and supports various types of transceiver modules. You can purchase transceiver modules for it as required.

Interface specifications

Table 20 Interface specifications

Item

Description

Connector

SFP/LC

Number of interfaces

1

Interface standard

SONET OC-3/SDH STM-1

Interface rate

155.52 Mbps

 

Interface LEDs

Figure 13 RT-SIC-1POS-STM1 panel

 

Table 21 LED description

LED

Status

Description

ACT/ALM

Steady green

A 155.52 Mbps link is present.

Flashing green

The port is receiving or sending data at 155.52 Mbps.

Steady red

An alarm has occurred.

Off

No transceiver module is present or the port is in shutdown state.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and connection methods, see "Fiber port."

E1/T1 interface modules

·     SIC-E1-F

·     SIC-2E1-F

·     RT-SIC-2E1-G

·     SIC-1EPRI

·     SIC-T1-F

SIC-E1-F

Introduction

The 1-port fractional E1 interface module (SIC-E1-F) supports:

·     Transmission/Receiving and handling of E1 data streams

·     CE1 (channelized E1) access

·     Remote loopback and local loopback functions, facilitating fault test and location.

The timeslots on an interface in FE1 mode on the SIC-E1-F can be bundled to form one interface (namely, can be bundled into one channel, and the rate of the interface is n No 64 Kbps, where n ranges from 1 to 31.)

The SIC-E1-F does not support the PRI mode.

Interface specifications

Table 22 Interface specifications

Item

Description

Connector type

D15

Number of connectors

1

Interface standard

·     G.703

·     G.704

Interface rate

2.048 Mbps

Cable type

75-ohm unbalanced coaxial cable (D15 to BNC)

Operating modes

·     E1

·     CE1

Supported services

·     Backup

·     Terminal access

 

Interface LEDs

Figure 14 SIC-E1-F panel

 

Table 23 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being transmitted or received.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: Neither loopback nor alarm is present.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

SIC-2E1-F

Introduction

The 2-port fractional E1 interface module (SIC-2E1-F), where F indicates fractional, supports:

·     Transmission/Receiving and handling of E1 data streams

·     CE1 (channelized E1) access

·     Remote loopback and local loopback functions, facilitating fault test and location

Interface specifications

Table 24 Interface specifications

Item

Description

Connector type

D15

Number of connectors

1

Interface standard

·     G.703

·     G.704

Interface rate

2.048 Mbps

Cable type

75-ohm unbalanced coaxial cable (D15 to BNC)

Operating modes

·     E1

·     CE1

Supported services

·     Backup

·     Terminal access

 

Interface LEDs

Figure 15 SIC-2E1-F panel

 

Table 25 LED description

LED

Description

LINK/ACT (left)

·     On: A carrier signal is received on line RX1.

·     Flashing: Data is being transmitted on line TX1 or received on line RX1.

·     Off: No carrier signal is received on line RX1.

LP/AL (left)

·     On: The interface of lines TX1 and RX1 is in loopback mode.

·     Flashing: No cable is connected to the interface of lines TX1 and RX1, the cable is damaged or not connected correctly, or the peer device is faulty.

·     Off: Neither loopback nor alarm is present on the interface of lines TX1 and RX1.

LINK/ACT (right)

·     On: A carrier signal is received on line RX2.

·     Flashing: Data is being transmitted on line TX2 or received on line RX2.

·     Off: No carrier signal is received on line RX2.

LP/AL (right)

·     On: The interface of lines TX2 and RX2 is in loopback mode.

·     Flashing: No cable is connected to the interface of lines TX2 and RX2, the cable is damaged or not connected correctly, or the peer device is faulty.

·     Off: Neither loopback nor alarm is present on the interface of lines TX2 and RX2.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connections methods, see "E1 interface."

RT-SIC-2E1-G

Introduction

The RT-SIC-2E1-G is a 2-port channelized CE1/PRI and fractional E1 (E1-F) interface module.

The module provides the following features:

·     Channelized CE1/PRI modeThe module allows arbitrary grouping of 31 channels and multiple bundles. It transmits/receives and handles E1 data streams, provides CE1 access, and supports ISDN PRI.

·     Unchannelized E1 modeInterfaces on the module are 2.048 Mbps synchronous serial interfaces without timeslot division.

·     Fractional E1 (E1-F) modeThe time slots can only be bundled into one n x 64 kbps channel, where the value range of n is 1 to 31. The module does not support PRI mode.

Interface specifications

Table 26 Interface specifications

Item

Description

Connector type

RJ-45

Number of connectors

2

Interface standard

G.703

Interface rate

2.048 Mbps

Cable type

·     E1 120-ohm balanced twisted pair cable: 2 m (6.56 ft), 15 m (49.21 ft), or 30 m (98.43 ft)

·     E1 75-ohm unbalanced coaxial cable

·     75-ohm adapter cable

·     Coaxial connector, network interface connector, and 75-ohm to 120-ohm adapter (with BNC connector)

Operating modes

·     Unchannelized E1 (G.703)

·     Channelized E1 (CE1/PRI)

·     Fractional E1 (E1-F)

Supported services

·     Backup

·     Terminal access service

·     ISDN PRI

 

 

NOTE:

The E1 cable after extension supports a maximum transmission distance of 100 m (328.08 ft).

 

Interface LEDs

Figure 16 RT-SIC-2E1-G panel

 

On the panel, each port corresponds to one green LED and one yellow LED.

Table 27 LED description

LED

Status

Description

LINK/ACT (green)

Steady green

A carrier signal has been received.

Flashing green

Data is being transmitted or/and received.

Off

No carrier signal has been received.

LP/AL (yellow)

Steady yellow

The interface is in loopback mode.

Flashing yellow

No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

Off

No loopback or alarm is present.

 

Jumper caps

The RT-SIC-2E1-G interface module provides jumper caps, the installation status of which determines the interface impedance. By default, each pin pair is installed with a jumper cap and the impedance of an E1 interface is 75 ohms.

Figure 17 Default installation status of jumper caps

 

To connect a 75-ohm cable to an E1 interface, install jumper caps on the pins corresponding to the interface. To connect a 120-ohm cable to an E1 interface, remove the jumper caps from the pins corresponding to the interface. Table 28 displays the mapping relations between pins and E1 interfaces.

Table 28 Mapping relations between pins and E1 interfaces

Pins

E1 interface

1 and 2

E1 interface 0

3 and 4

E1 interface 0

5 and 6

E1 interface 1

7 and 8

E1 interface 1

9 and 10

Reserved. Keep the jumper cap in its default installation status.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

SIC-1EPRI

Introduction

The SIC-1EPRI is a 1-port E1/CE1/PRI SIC interface module that provides the following features:

·     Transmission/Receiving and handling of E1 data streams.

·     CE1 (channelized E1) access.

·     ISDN PRI function.

·     Remote loopback and local loopback functions, facilitating fault test and location.

You can use the module for multiple purposes through different configurations.

Interface specifications

Table 29 Interface specifications

Item

Description

Connector type

D15

Number of connectors

1

Interface standard

·     G.703

·     G.704

Interface rate

2.048 Mbps

Cable type

·     75-ohm unbalanced coaxial cable (D15 to BNC)

·     Coaxial connector, network interface connector, and 75-ohm to 120-ohm adapter

NOTE:

The default resister for the interface on the SIC-1EPRI is 75 ohm. A 75-ohm to 120-ohm adapter must be used when a 120-ohm cable is connected to the SIC-1EPRI.

Operating mode

·     E1

·     CE1

·     ISDN PRI

Supported service

·     Backup

·     Terminal access

·     ISDN

 

Interface LEDs

Figure 18 SIC-1EPRI panel

 

Table 30 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being transmitted or received.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

·     Off: Neither loopback nor alarm is present.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connections methods, see "E1 interface."

SIC-T1-F

Introduction

1-port Fractional T1 interface card (SIC-T1-F) has the following features:

·     The timeslots on an interface in FT1 mode on the SIC-T1-F can be bundled to form one interface (namely, can be bundled into one channel, and the rate of the interface is n No 56 Kbps, where n ranges from 1 to 24.).

·     The SIC-T1-F does not support the PRI mode.

Interface specifications

Table 31 Interface specifications

Item

Description

Connector type

RJ-45

Number of connectors

1

Interface standard

·     G.703/T1.102

·     G.704

·     AT&T TR 54016

·     AT&T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm standard shielded network cable)

Operating mode

FT1

Supported service

·     Backup

·     Terminal access

 

Interface LEDs

Figure 19 SIC-T1-F panel

SIC-1T1-F

 

Table 32 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being transmitted or/and received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

Serial interface modules

·     SIC-8AS

·     SIC-16AS

·     SIC-1SAE

·     SIC-2SAE

·     SIC-4SAE

·     SIC-4RS

SIC-8AS

Introduction

The 8-port asynchronous serial interface module (SIC-8AS) mainly transmits and processes asynchronous data streams.

SIC-8AS has these features:

·     Each asynchronous serial port provides a rate up to 115.2 Kbps.

·     Supports the terminal access service and asynchronous dedicated line.

·     Serves as the small-/medium-sized ISP dial-up access server when an asynchronous serial port is used for dial-up.

Interface specifications

Table 33 Interface specifications

Item

Description

Connector

DB60

Number of connectors

1

Interface cable

Customized cable with 8-port RJ-45 connector

Interface standard

RS-232

Minimum baud rate

300 bps

Maximum baud rate

115.2 Kbps

Supported services

·     Modem dial-up

·     Backup

·     Terminal access service

·     Asynchronous dedicated line

 

Interface LEDs

Figure 20 SIC-8AS front panel

SIC-8AS+口

 

Table 34 LED description

LED

Description

LINK/ACT

·     Off: No link is present.

·     On: A link is present.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

SIC-16AS

Introduction

The 16-port asynchronous serial interface module (SIC-16AS) mainly transmits and processes asynchronous data streams.

SIC-16AS features the following:

·     Each asynchronous serial port provides a rate of up to 115.2 Kbps.

·     Supports the terminal access service and asynchronous dedicated line.

·     Serves as the small-/medium-sized ISP dial-up access server when an asynchronous serial port is used for dial-up.

Interface specifications

Table 35 Interface specifications

Item

Description

Connector

D28 (male)

Number of connectors

1

Interface cable

Customized cable with 16-port RJ-45 connector (female)

Interface standard

RS-232

Minimum baud rate

300 bps

Maximum baud rate

115.2 Kbps

Supported services

·     Modem dial-up

·     Backup

·     Terminal access service

·     Asynchronous dedicated line

 

Interface LEDs

Figure 21 SIC-16AS panel

SIC-16AS

 

Table 36 LED description

LED

Description

LINK/ACT

·     Off: No link is present.

·     On: A link is present.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

SIC-1SAE/SIC-2SAE/SIC-4SAE

Introduction

The SIC-1SAE/SIC-2SAE/SIC-4SAE is a 1-port/2-port/4-port enhanced high-speed synchronous/asynchronous serial interface module.

Interface specifications

Table 37 Interface specifications

Item

Synchronous

Asynchronous

Connector

D28

Number of connectors

·     1 (SIC-1SAE)

·     2 (SIC-2SAE)

·     4 (SIC-4SAE)

Interface standard and operating mode

V.24

·     V.35

·     RS449

·     X.21

·     RS-530

RS-232

·     DTE

·     DCE

·     DTE

·     DCE

Minimum baud rate

(bps)

1200

1200

300

Maximum baud rate

(bps)

64 k

2.048 M

115.2

Cable

·     V.24 (RS-232) DTE cable

·     V.24 (RS-232) DCE cable

·     V.35 DTE cable

·     V.35 DCE cable

·     X.21 DTE cable

·     X.21 DCE cable

·     RS449 DTE cable

·     RS449 DCE cable

·     RS530 DTE cable

·     RS530 DCE cable

Supported service

·     DDN leased line

·     Terminal access service

·     Dialup through modems

·     Backup

·     Asynchronous leased line

·     Terminal access

 

Interface LEDs

Figure 22 SIC-1SAE panel

SIC-1SAE+口

 

Figure 23 SIC-2SAE panel

 

Figure 24 SIC-4SAE panel

 

The SIC-1SAE provides separate LINK and ACT LEDs for the port and the SIC-2SAE and SIC-4SAE provide one LINK/ACT LED for each port.

Table 38 LED description for the port on the SIC-1SAE

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received;

·     Flashing: Data is being received or/and transmitted.

 

Table 39 LED description for ports on the SIC-2SAE/SIC-4SAE

LED

Description

LINK/ACT

·     Off: No link is present.

·     On: A link is present.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about synchronous/asynchronous serial port cables and the connection methods, see "Synchronous/asynchronous serial ports."

SIC-4RS

Introduction

The SIC-4RS is a 4-port asynchronous serial interface module.

The SIC-4RS has these features:

·     Allows users to make matching wires connected to the terminal block themselves.

·     Supports simultaneous connection to four asynchronous serial ports.

Interface specifications

Table 40 Interface specifications

Item

Description

Connector

Terminal block

Number of connectors

1

Interface cable

Allows users to make matching cables themselves.

Interface standard and operating mode

RS-232/485/422

Minimum baud rate (bps)

300

Maximum baud rate (bps)

115200

Supported service

·     4 asynchronous serial port connection

·     2-channel digital input (DI) detection

 

 

NOTE:

The interface standards and operating mode of the SIC-4RS interface module are switched by using DIP switches. For more information about DIP switches, see "Dual inline package switch."

 

Interface LEDs

Figure 25 SIC-4RS panel

 

Table 41 LED description

LED

Description

0 to 3

·     Off: No link is present.

·     On: A link is present.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

The SIC-4RS interface module allows users to make matching cables themselves for connection to it. Figure 26 and Table 42 describe the requirements for making matching cables.

Figure 26 Pin numbering

 

Table 42 Interface pinouts

Pin

Interface standards and working modes

RS-232

RS-422

RS-485

1

RTS0

TX0+

Data0+

2

TXD0

TX0-

Data0-

3

RXD0

RX0+

 

4

CTS0

RX0-

 

5

GND

6

GND

7

RTS1

TX1+

Data1+

8

TXD1

TX1-

Data1-

9

RXD1

RX1+

 

10

CTS1

RX1-

 

11

GND

12

GND

13

RTS2

TX2+

Data2+

14

TXD2

TX2-

Data2-

15

RXD2

RX2+

 

16

CTS2

RX2-

 

17

GND

18

GND

19

RTS3

TX3+

Data3+

20

TXD3

TX3-

Data3-

21

RXD3

RX3+

 

22

CTS3

RX3-

 

23

GND

24

GND

25

DN0_P

26

DN0_N

27

DN1_P

28

DN1_N

 

Dual inline package switch

The SIC-4RS interface module provides a dual inline package (DIP) switch. The DIP switch setting defines the interface standards and the grounding method. By default, all DIP switches are OFF. That is, the interface standards and the grounding method are RS232.

The SIC-4RS interface module provides two DIP switches, S1 and S2, to control different interfaces, as shown in Table 43. For information about the configuration method and description for switches S1 and S2, as shown in Table 44 and Table 45.

Table 43 DIP switch-to-interface map

DIP

Corresponding interface

S1

Interfaces 0 and 1

S2

Interfaces 2 and 3

 

Table 44 DIP switch S1 configuration

Pin and its status

Pin and its status

Pin and its status

Pin and its status

Pin and its status

Pin and its status

Port/mode

1

2

3

4

5

6

N/A

OFF

ON

ON

/

/

/

0-port RS-232

ON

OFF

ON

/

/

/

0-port RS-485

ON

ON

OFF

/

/

/

0-port RS-422

/

/

/

OFF

ON

ON

1-port RS-232

/

/

/

ON

OFF

ON

1-port RS-485

/

/

/

ON

ON

OFF

1-port RS-422

 

Table 45 DIP switch S2 configuration

Pin and its status

Pin and its status

Pin and its status

Pin and its status

Pin and its status

Pin and its status

Port/mode

1

2

3

4

5

6

N/A

OFF

ON

ON

/

/

/

2-port RS-232

ON

OFF

ON

/

/

/

2-port RS-485

ON

ON

OFF

/

/

/

2-port RS-422

/

/

/

OFF

ON

ON

3-port RS-232

/

/

/

ON

OFF

ON

3-port RS-485

/

/

/

ON

ON

OFF

3-port RS-422

 

Analog modem interface modules

·     SIC-1AM

·     SIC-2AM

SIC-1AM/SIC-2AM

Introduction

The 1/2-port analog modem interface module (SIC-1AM/SIC-2AM) integrates the functions of asynchronous interface and external modem, that is, allowing 1/2 channel(s) of remote modem subscribers to directly access the Router. They support:

·     Data rate of 56 kbps.

·     Accessing and handling analog signals and transmitting the processed data to the Router host through the serial interface bus. And also, processing the data received from the host and then transmitting them to the PSTN via the telephone port.

Interface specifications

Table 46 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

·     1 (SIC-1AM)

·     2 (SIC-2AM)

Cable type

Telephone cable with ferrite core

Maximum speed

56 kbps

Supported standard

·     ITU-T V.90

·     K56flex

·     V.34 (33.6 kbps)

·     V.FC

·     V.32 bis

·     V.32

·     V.22 bis

·     V.22A/B

·     V.23

·     V.21

·     Bell 212A a

·     Bell 103

Supported service

Modem dial-up

 

Interface LEDs

Figure 27 SIC-1AM panel

 

Figure 28 SIC-2AM panel

 

Table 47 LED description

LED

Description

LINK

·     Off: The link is idle.

·     On: The connection has been established.

·     Flashing: The connection is being set up.

ACT

·     Off: The link is idle.

·     Flashing: Data is being transmitted or received.

 

Interface cables and the connection methods

For more information about the Ethernet interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

XDSL interface modules

·     SIC-1ADSL

·     SIC-1ADSL-I

SIC-1ADSL

Introduction

The 1-port ADSL over PSTN interface module (SIC-1ADSL) provides an RJ-11 interface that can work as a WAN interface. It allows a LAN subscriber to connect to the digital subscriber's loop access multiplexer (DSLAM) at the central office over a regular analog subscriber line or telephone line. Thus, the subscriber can access the ATM/IP backbone or the Internet to enjoy services such as high-speed data communication and video on demand (VoD).

ADSL transmits data in the high frequency band above 26 kHz. Therefore, it can provide services without interfering with the voice service being provided in the low frequency band (0 to 4 kHz) on the same line. It provides downlink rates in the range 32 kbps to 8 Mbps and uplink rates in the range 32 kbps to 1 Mbps.

The SIC-1ADSL delivers these features:

·     Manual ADSL line activation and deactivation, providing a convenient fault location means.

·     Interface standards of G. DMT, G. Lite, and T1.413, autosensing.

·     Trellis coding (except for G. Lite) on ADSL interfaces, enhancing the stability of ADSL connection.

Interface specifications

Table 48 Interface specifications

Item

Description

Connector

RJ-11

Number of connectors

1

Interface rate

·     In ADSL full rate mode (ITU-T 992.1 G.DMT/ANSI T1.413):

¡     8 Mbps (downlink rate)

¡     1024 kbps (uplink rate)

·     In ADSL Lite mode (ITU-T 992.2 G.Lite):

¡     64 kbps to 1 Mbps (downlink rate)

¡     64 kbps to 512 kbps (uplink rate)

·     In ADSL2+ full rate mode (ITU-T 992.5):

¡     24 Mbps (downlink rate)

¡     1024 kbps (uplink rate)

Interface standard

·     ITU-T 992.1 G.DMT

·     ITU-T 992.2 G.Lite

·     ANSI T1.413 Issue 2

·     ITU-T 992.3

·     ITU-T 992.5

Cable

Telephone cable

Supported service

ADSL over the regular telephone line

Maximum received and sent frame

1700 bytes

 

Interface LEDs

Figure 29 SIC-1ADSL panel

SIC-1ADSL

 

Table 49 LED description

LED

Description

LINK

·     Off: The loop is inactive.

·     On: The loop has been activated and has entered the data mode

·     Flashing: The loop is being activated.

ACT

·     Off: No data is being transmitted or received.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about ADSL interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

SIC-1ADSL-I

Introduction

The 1-port ADSL over ISDN interface module (SIC-1ADSL-I) uses the RJ-11 connector for the WAN interface. It allows a LAN subscriber to connect to the DSLAM at the central office over a regular analog subscriber line or telephone line. Thus, the subscriber can access the ATM/IP backbone or the Internet to enjoy services such as high-speed data communication and video on demand (VoD).

The module transmits data in the high frequency band above 138 kHz. Therefore, it can provide services on the same line without interfering with the ISDN service being provided on the same line. It provides downlink rates in the range 32 kbps to 8 Mbps and uplink rates in the range 32 kbps to 1 Mbps.

The SIC-1ADSL-I interface module delivers these features:

·     Manual ADSL line activation and deactivation, providing a convenient fault location means

·     A G.992.1-compliant interface, autosensing

·     Trellis coding on ADSL interfaces, enhancing the stability of ADSL connection

Interface specifications

Table 50 Interface specifications

Item

Description

Connector

RJ-11

Number of connectors

1

Interface rate

·     In ADSL full rate mode (ITU-T 992.1 G.DMT/ANSI T1.413):

¡     8 Mbps (downlink rate)

¡     1024 kbps (uplink rate)

·     In ADSL Lite mode (ITU-T 992.2 G.Lite):

¡     64 kbps to 1 Mbps (downlink rate)

¡     64 kbps to 512 kbps (uplink rate)

·     In ADSL2+ full rate mode (ITU-T 992.5):

¡     24 Mbps (downlink rate)

¡     1024 kbps (uplink rate)

Interface standard

·     ITU-T 992.1 G.DMT

·     ITU-T 992.2 G.Lite

·     ANSI T1.413 Issue 2

·     ITU-T 992.3

·     ITU-T 992.5

Interface rate

·     Downlink: 8 Mbps

·     Uplink: 1024 kbps

Interface cable

Regular telephone cable

Supported services

ADSL over ISDN

Maximum received and sent frame

1700 bytes

 

Interface LEDs

Figure 30 SIC-1ADSL-I panel

SIC-1ADSL-I-新+口

 

Table 51 LED description

LED

Description

LINK

·     Off: No link is present;

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about ADSL interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

ISDN BRI interface modules

·     SIC-1BS

·     SIC-2BS

SIC-1BS/SIC-2BS

Introduction

The 1/2-port ISDN BRI S/T interface module (SIC-1BS/SIC-2BS) is mainly used to transmit, receive, and process ISDN BRI S/T traffic flows.

The SIC-1BS/SIC-2BS has two operating modes: dial-up and leased line.

Interface specifications

Table 52 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

·     1 (SIC-1BS)

·     2 (SIC-2BS)

Cable type

Telephone cable with ferrite core

Interface standard

·     ITU-T I.430

·     Q.921

·     Q.931

Operating mode

·     ISDN Dial-up

·     ISDN leased line

Supported services

·     ISDN

·     ISDN supplementary services

·     Multi-subscriber number

·     Sub-address

·     Backup

 

Interface LEDs

Figure 31 SIC-1BS panel

 

Figure 32 SIC-2BS panel

 

Table 53 LED description

LED

Description

B1

·     Off indicates the B1 channel is idle.

·     Flashing indicates the B1 channel is being used for data communication.

B2

·     Off indicates the B2 channel is idle.

·     Flashing indicates the B1 channel is being used for data communication.

ACT

·     Off indicates the inactive state.

·     Steady on indicates the active state.

ON

·     Off indicates interface module is powered off.

·     On indicates the interface module is powered on.

 

Interface cables and the connection methods

For more information about BS interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

Voice interface modules

·     SIC-1FXS

·     SIC-1FXO

·     SIC-2FXS

·     SIC-2FXO

·     SIC-2FXS1FXO

·     DSIC-4FXS1FXO

·     SIC-1BSV

·     SIC-2BSV

·     SIC-1VE1

·     SIC-1VT1

·     SIC-1VE1T1

SIC-1FXS/SIC-1FXO/SIC-2FXS/SIC-2FXO

Introduction

The 1/2-port voice subscriber circuit interface module (SIC-1FXS/SIC-2FXS) and 1/2-port voice AT0 analog trunk interface module (SIC-1FXO/SIC-2FXO) serve to access and handle 1/2 channel(s) of analog voice signals over data communication networks. The differences between SIC-FXS and SIC-FXO are listed below:

·     SIC-FXS modules are analog subscriber line modules that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges.

·     SIC-FXO modules are loop trunk modules that provide access of common subscriber lines of exchanges.

Interface specifications

Table 54 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

1 (SIC-1FXS/SIC-1FXO)

2 (SIC-2FXS/SIC-2FXO)

Interface standard

·     Subscriber circuit interface (SIC-1FXS/SIC-2FXS) compliant with ITU Q.512.

·     Loop trunk interface (SIC-1FXO/SIC-2FXO) compliant with ITU Q.552.

·     Over-current and over-voltage protection compliant with ITU K.20

Cable type

Telephone cable with ferrite core.

Dialing mode

Supports DTMF, not supports pulse dial-up.

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 33 SIC-1FXS panel

SIC-1FXS

 

Figure 34 SIC-1FXO panel

SIC-1FXO

 

Figure 35 SIC-2FXS panel

SIC-2FXS

 

Figure 36 SIC-2FXO panel

SIC-2FXO

 

Table 55 LED description

LED

Description

LINK

·     Off: The link is idle.

·     On: The link is being occupied for call connection.

ACT

·     Off: The link is idle.

·     On: The link is being occupied for communication.

 

Interface cables and the connection methods

For more information about FXS/FXO interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

SIC-2FXS1FXO

Introduction

The 2-port analog subscriber circuit interface module and 1-port voice AT0 loop trunk interface module (SIC-2FXS1FXO) serve to access and handle three channels of analog voice signals over data communication networks. Two FXS interfaces and one FXO interface are available on a SIC-2FXS1FXO module:

·     FXS interfaces are analog subscriber line interfaces that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges.

·     FXO interfaces are loop trunk interfaces that provide access of common subscriber lines of exchanges.

Interface specifications

Table 56 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

2 FXS interfaces

1 FXO interface

Interface standard

·     Supports subscriber circuit interface (FXS), compliant with ITU Q.512

·     Supports loop trunk interface (FXO), compliant with ITU Q.552

·     Over-current and over-voltage protection compliant with ITU K.20

Cable type

Telephone cable with ferrite core

Dial-up mode

Supports DTMF, compliant with GB3378, but does not support pulse dial-up.

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 37 SIC-2FXS1FXO panel

SIC-2FXS1FXO+口

 

Table 57 LED description

LED

Description

LINK/ACT

·     Off: The link is idle.

·     Steady green: The link is being occupied for call connection.

·     Flashing yellow: The link is being occupied for communication.

 

Interface cables and the connection methods

For more information about FXS/FXO interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

DSIC-4FXS1FXO

Introduction

The 4-port analog subscriber circuit interface module and 1-port voice AT0 loop trunk interface module (DSIC-4FXS1FXO) serve to access and handle five channels of analog voice signals over data communication networks.

·     FXS interfaces are analog subscriber line interfaces that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges.

·     FXO interfaces are loop trunk interfaces that provide access of common subscriber lines of exchanges.

Interface specifications

Table 58 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

4 FXS interfaces

1 FXO interface

Interface standard

·     Supports subscriber circuit interface (FXS), compliant with ITU Q.512

·     Supports loop trunk interface (FXO), compliant with ITU Q.552

·     Over-current and over-voltage protection compliant with ITU K.20

Cable type

Telephone cable with ferrite core

Dial-up mode

Supports DTMF, compliant with GB3378, but does not support pulse dial-up.

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 38 DSIC-4FXS1FXO panel

DSIC-4FXS1FXO+口

 

Table 59 LED description

LED

Description

LINK/ACT

·     Off: The link is idle.

·     Steady green: The link is being occupied for call connection.

·     Flashing yellow: The link is being occupied for communication.

 

Interface cables and the connection methods

For more information about FXS/FXO interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

SIC-1BSV/SIC-2BSV

Introduction

The 1/2-port ISDN BRI S/T voice interface module (SIC-1BSV/SIC-2BSV) is mainly used to process (receive/transmit and compress/decompress) the ISDN interface voice traffic. The interface(s) on the SIC-1BSV/SIC-2BSV module is (are) ITU-T I.430-compliant, adopting pseudo-ternary coding, providing 192 Kbps interface rate, and allowing the maximum transmission distance of 1 km (0.6 miles) in point-to-point mode. In the upstream direction, the SIC-1BSV/SIC-2BSV module can be connected to a user interface on an ISDN switch to receive and decompress, compress and transmit ISDN BRI digital voice traffic. In the downstream direction, the module can be connected to a TE device to forward the voice packets from the TE device to the Internet through a WAN interface on the router, thus implementing VoIP. The module has the following features.

·     A BSV interface supports two modes: user and network, respectively for connecting an ISDN network and a TE device.

·     When a BSV interface works in network mode, traffic is processed as follows: The digital voice traffic received on the BSV interface is compressed and forwarded through the CPU on the main control board to a WAN interface. The IP voice traffic received on a WAN interface is forwarded through the CPU on the main control board to SIC-1BSV/SIC-2BSV, where the traffic is decompressed and sent to the TE device.

·     When a BSV interface works in user mode, traffic is processed as follows: The digital voice traffic received from the B channels on the BSV interface is decompressed and forwarded through the CPU on the main control board to a local FXS or FXO analog voice interface. The voice signals received on the local FXS or FXO analog voice interface are processed by VoIP and forwarded through the CPU on the main control board to SIC-1BSV/SIC-2BSV, where the traffic is compressed and sent out of the BSV interface to the ISDN switch.

·     Working in conjunction with the FXS or FXO analog voice interface modules, SIC-2BSV provides flexibility in voice call routing.

·     The ISDN BRI D channel signaling is processed separately on CPU.

·     A BSV interface supports remote power supply and thus can be connected directly to an ISDN phone, saving extra power supply device.

·     The SIC-1BSV/SIC-2BSV is dedicated to voice applications, which is different from the BS interface modules where BRI data applications are supported.

Interface specifications

Table 60 Interface specifications

Item

SIC-1BSV

SIC-2BSV/

Connector

RJ-45

Number of connectors

1

2

Interface standard

·     ITU-T I.430

·     Q.921

·     Q.931

Interface rate

192 Kbps

Cable

ISDN S interface cable

Supported service

Voice access over ISDN S interface cable

 

Interface LEDs

Figure 39 SIC-1BSV panel

SIC-1BSV

 

Figure 40 SIC-2BSV panel

SIC-2BSV

 

Table 61 LED description

LED

Description

B1

Green

Flashing indicates data is being transmitted or received on B1 channel.

B2

Green

Flashing indicates data is being transmitted or received on B2 channel.

ACT

Yellow

·     Flashing indicates the link is being activated.

·     Steady on indicates the link is active.

ON

Green, power LED.

Steady on indicates the module is powered on.

 

Interface cables and the connection methods

For more information about BSV interface cables and the connection methods, see "BSV/BSE interface."

SIC-1VE1

Introduction

The 1-port E1 voice interface module (SIC-1VE1) can handle dense voice signals in VoIP system. It provides a CE1/PRI/R2 port, allowing the access of 30 channels of voice signals.

Interface specifications

Table 62 Interface specifications

Item

Description

Connector

DB 15

Number of connector

1

Interface standard

G.703, G.704

Interface rate

2.048 Mbps

Frame format

·     Ethernet_II

·     Ethernet_SNAP

·     IEEE 802.2

·     IEEE 802.3

Cable type

·     75-ohm unbalanced coaxial cable

·     120-ohm balanced twisted pair cable

·     Coaxial connector, network interface connector and 75-ohm to 120-ohm adapter (with BNC connector)

Operation mode

CE1

ISDN PRI (only supported by SIC-1VE1)

R2

Services

·     Backup

·     Terminal access

·     ISDN (only supported by SIC-1VE1)

 

Interface LEDs

Figure 41 SIC-1VE1 panel

 

Table 63 LED description

LED

Description

LINK

·     Off: The link is idle.

·     On: The link is being occupied for call connection.

ACT

·     Off: The link is idle.

·     On: The link is being occupied for communication.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

SIC-1VT1

Introduction

The 1-port T1 voice interface module (SIC-1VT1) can handle dense voice signals in VoIP system. It provides a CT1/PRI/R2 port, allowing the access of 23 channels of voice signals.

Interface specifications

Table 64 Interface specifications

Item

Description

Connector

RJ-45

Number of connector

1

Interface standard

·     G.703/T1.102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm standard shielded cable)

Operation mode

CT1

ISDN PRI

Services

Backup

Terminal access

ISDN

 

Interface LEDs

Figure 42 SIC-1VT1 panel

 

Table 65 LED description

LED

Description

LINK

·     Off: The link is idle.

·     On: The link is being occupied for call connection.

ACT

·     Off: The link is idle.

·     On: The link is being occupied for communication.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

SIC-1VE1T1

Introduction

The 1-port E1/T1 voice interface module SIC-1VE1T1 handles dense voice signals in VoIP and FoIP systems. The E1 module transmits, receives, and processes E1 voice signals. It allows the interface to operate in CE1 mode or ISDN PRI mode to process a maximum of 30 channels of voice signals. The T1 module transmits, receives, and processes T1 voice signals. It allows the interface to operate in CT1 mode or ISDN PRI mode to process a maximum of 23 channels of voice signals.

You can use command lines and a jumper to configure the interface as a 75-ohm E1 interface, 100-ohm T1 interface, or 120-ohm E1 interface. By default, the interface is a 75-ohm E1 interface.

·     To configure the interface as a 75-ohm E1 interface, connect the jumper to pins 1 and 2, pins 7 and 8, pins 11 and 12, and pins 13 and 14.

·     To configure the interface as a 100-ohm T1 or 120-ohm E1 interface, connect the jumper to pins 1 to 3, pins 5 to 7, pins 9 and 10, and pins 11 to 13.

Figure 43 Jumper connecting methods

 

Interface specifications

Table 66 Interface specifications

Item

Specification

Connector

RJ-45

Number of connector

1

Interface standard

·     G.703

·     G.704

Interface rate

·     E1 interface: 2.048 Mbps

·     T1 interface: 1.544 Mbps

Cable type

·     E1 75-ohm coaxial cable

·     E1 120-ohm twisted pair cable: 2 m (6.56 ft), 15 m (49.21 ft), or 30 m (98.43 ft)

·     T1 100-ohm standard shielded cable

·     Coaxial connector, network interface connector, or 75-to-120-ohm adapter (with BNC connector)

Operating mode

·     E1

·     T1

·     CE1T1

·     ISDN PRI

Services

Backup

Terminal access

ISDN PRI

 

Interface LEDs

Figure 44 SIC-1VE1T1 panel

 

Table 67 LED description

LED

Description

LINK/ACT

·     Steady green: Carrier signal has been received.

·     Flashing green at 4 Hz: Data is being transmitted or received.

·     Off: No carrier signals have been received.

LP/AL

·     Steady yellow: The interface is in loopback mode.

·     Flashing yellow at 0.5 Hz: An AIS, LFA, or RAI alarm is present.

·     Off: Neither loopback nor alarm is present.

 

Interface cables and connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

For more information about T1 interface cables and the connection methods, see "T1 interface."

3G interface modules

·     SIC-3G-CDMA

·     SIC-3G-TD

·     SIC-3G-HSPA

SIC-3G-CDMA

Introduction

The SIC-3G-CDMA module is used to access 3G WLANs. It supports:

·     CDMA 2000 1x RTT

·     1x EV-DO Rev.0

·     1x EV-DO Rev.A

Interface specifications

Table 68 Interface specifications

Item

Description

Connector type

·     TNC RF: Antenna for accessing WLANs.

·     RJ-45: For connecting to a third-party WLAN debugging and testing software such as CAIT of Qualcomm.

Number of connectors

·     2 TNC RF

·     1 RJ-45

Interface standard

·     TNC RF: Omni antenna, supporting CDMA 2000 1 No RTT, 1 No EV-DO Rev.0, 1 No EV-DO Rev.A.

·     RJ-45: RS-232

Cable type

·     TNC RF: None

·     RJ-45: AUX cable

Rates

Network standards:

·     1 No EV-DO Rev.A (Downlink: 3.1 Mbps, uplink: 1.8 Mbps)

·     1 No EV-DO Rev.0 (Downlink: 2.4 Mbps, uplink: 153.6 Kbps)

·     1 No RTT (Downlink: 153.6 Kbps, uplink: 153.6 Kbps)

Services

·     CDMA 2000 1x RTT

·     1 No EV-DO Rev.0

·     1 No EV-DO Rev.A

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 45 SIC-3G-CDMA panel

 

Table 69 LED description

LED

Description

WWAN

·     Steady green indicates that a link is present.

·     Flashing green indicates that data is being transmitted or received.

RSSI

·     Steady green indicates strong signal.

·     Flashing green indicates middle or low signal.

·     Off indicates weak signal or no signal.

1xRTT

·     Steady yellow indicates the service is valid.

·     Off indicates no service.

EVDO

·     Steady yellow indicates the service is valid.

·     Off indicates no service.

 

Antennas, interface cables, and the connection methods

For more information about SIC-3G-CDMA antennas, interface cables, and the connection methods, see "3G interface."

Installing a SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the SIM card fits into the beveled corner of the SIM socket.

 

To installing a SIM card:

1.     Open the SIM card socket in the direction marked OPEN so the holder projects upwards.

2.     Insert the SIM card into the SIM card socket along the guide rails.

3.     Close the SIM card socket in the direction marked LOCK to lock the card in position.

4.     Execute the display cellular [ interface-number ] command after the router is started. When "SIM Status = OK" appears in the output information, the SIM card is identified.

SIC-3G-TD

Introduction

The SIC-3G-TD module provides access to 3 G WLANs. It supports the following features:

·     GPRS

·     EDGE

·     TD-SCDMA

·     HSDPA

Interface specifications

Table 70 Interface specifications

Item

Description

Connector type

TNC: For connecting an antenna and accessing WLANs.

RJ-45: For connecting to a third-party WLAN debugging and testing software such as CAIT of Qualcomm.

Number of connectors

1 TNC RF

1 RJ-45

Interface standard

TNC RF: Omni antenna, supporting GPRS/EDGE/TD-SCDMA/HSDPA

RJ-45: RS-232

Cable type

TNC RF: None

RJ-45: AUX cable

Rates

·     HSDPA (downlink: 2.8 Mbps, uplink: 384 Kbps)

·     TD-SCDMA (downlink: 384 Mbps, uplink: 384 Kbps)

·     EDGE (downlink: 236.8 Kbps, uplink: 236.8 Kbps)

·     GPRS (downlink: 85.6 Kbps, uplink: 85.6 Kbps)

Services

GPRS/EDGE/TD-SCDMA/HSDPA

 

Interface LEDs

Figure 46 SIC-3G-TD panel

 

Table 71 LED description

LED

Description

WWAN

·     Steady green: A link is present.

·     Flashing green: Data is being transmitted or received.

RSSI

·     Steady green: Strong signal.

·     Flashing green: Middle or low signal.

·     Off: Weak signal or no signal.

TD

·     Steady yellow: The service is valid.

·     Off: No service.

HSDPA

·     Steady yellow: The service is valid.

·     Off: No service.

 

Antennas, interface cables, and the connection method

For more information about SIC-3G-GSM antennas, interface cables, and the connection methods, see "3G interface."

Installing a SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the SIM card fits into the beveled corner of the SIM socket.

 

To install a SIM card:

1.     Open the SIM card socket in the direction marked OPEN so the holder projects upwards.

2.     Insert the SIM card into the SIM card socket along the guide rails.

3.     Close the SIM card socket in the direction marked LOCK to lock the card in position.

4.     Execute the display cellular [ interface-number ] command after the router is started. When "SIM Status = OK" appears in the output information, the SIM card is identified.

SIC-3G-HSPA

Introduction

The SIC-3G-HSPA module serves to access 3G networks. It supports:

·     GPRS

·     EDGE

·     UMTS

·     HSDPA

Interface specifications

Table 72 Interface specifications

Item

Description

Connector type

TNC: For connecting an antenna and accessing WLANs.

RJ-45: For connecting to a third-party WLAN debugging and testing software such as CAIT of Qualcomm.

Number of connectors

2 TNC RF

1 RJ-45

Interface standard

TNC RF: Omni antenna, supporting GPRS/EDGE/UMTS/HSDPA.

RJ-45: RS-232

Cable type

TNC RF: None

RJ-45: AUX cable

Rates

·     HSDPA (downlink: 7.2 Mbps)

·     HSUPA (uplink: 5.76 Mbps)

·     UMTS (downlink: 384 Mbps, uplink: 384 Kbps)

·     EDGE (downlink: 236.8 Kbps, uplink: 236.8 Kbps)

·     GPRS (downlink: 85.6 Kbps, uplink: 85.6 Kbps)

Services

GPRS/EDGE/UMTS/HSDPA

Supported wireless band

850/900/1900/2100 MHz WCDMA/HSDPA/HSUPA

850/900/1800/1900 MHz GPRS/EDGE

 

Interface LEDs

Figure 47 SIC-3G-HSPA panel

SIC-3G-HSPA

 

Table 73 LED description

LED

Description

WWAN

·     Steady green: A link is present.

·     Flashing green: Data is being transmitted or received.

RSSI

·     Steady green: Strong signal.

·     Flashing green: Middle or low signal.

·     Off: Weak signal or no signal.

UMTS

·     Steady yellow: The service is valid.

·     Off: No service.

HSDPA

·     Steady yellow: The service is valid.

·     Off: No service.

 

Antennas, interface cables, and the connection methods

CAUTION

CAUTION:

The 3G antenna provided with the SIC-3G-HSPA must be installed on the antenna port that has a MAIN mark.

 

For more information about SIC-3G-HSPA antennas, interface cables, and the connection methods, see "3G interface."

Installing a SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the SIM card fits into the beveled corner of the SIM socket.

 

To install a SIM card:

1.     Open the SIM card socket in the direction marked OPEN so the holder projects upwards.

2.     Insert the SIM card into the SIM card socket along the guide rails.

3.     Close the SIM card socket in the direction marked LOCK to lock the card in position.

4.     Execute the display cellular [ interface-number ] command after the router is started. When "SIM Status = OK" appears in the output information, the SIM card is identified.

4G interface modules

·     SIC-4G-LTE-M

·     SIC-4G-CNDE

·     RT-SIC-4G-CAT6

·     SIC-D4G-CNDE

SIC-4G-LTE-M

Introduction

The SIC-4G-LTE-M module provides 4G WLAN access and supports the following features:

·     LTE

·     UMTS

·     HSPA+

·     TD-SCDMA

·     CDMA2000 1xRTT

·     CDMA2000 1x-Ev-Do

·     Quad-Band EDGE

·     GPRS

·     GSM

Interface specifications

Table 74 Interface specifications

Item

Description

Connector type

·     TNCFor accessing WLANs.

·     SMA—For accessing GPS.

·     Mini USB Type ABFor connecting to third-party WLAN debugging and testing software such as CAIT of Qualcomm.

Number of connectors

·     2 TNCs

·     1 SMA

·     1 Mini USB Type AB

Interface standard

·     TNCSupports LTE, UMTS, HSPA+, CDMA 1x, EV-DO Rev A, Quad-Band EDGE, GPRS, and GSM

·     SMAGPS

·     Mini USB Type ABRS-232

Cable type

·     SMAFlexible 174 sized cable

·     TNCNone

·     Mini USB Type ABUSB console cable

Services

·     LTE

·     UMTS

·     HSPA+

·     TD-SCDMA

·     CDMA2000 1xRTT

·     CDMA2000 1x-Ev-Do

·     Quad-Band EDGE

·     GPRS

·     GSM

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 48 SIC-4G-LTE-M panel

 

Table 75 LED description

LED

Description

WWAN

·     Steady green indicates that a link is present.

·     Fast flashing green indicates that data is being transmitted or received.

·     Slowly flashing green indicates network searching.

·     Off indicates that no link is present.

RSSI

·     Steady green indicates strong signal (RSSI ≥ –69 dBm).

·     Fast flashing green indicates middle signal (–89 dBm ≤ RSSI <–69 dBm).

·     Slowly flashing green indicates low signal (–99 dBm ≤ RSSI < –89 dBm).

·     Off indicates weak signal or no signal (RSSI < –99 dBm).

HSPA+

·     Steady green indicates that the HSPA+ service or HSDPA service is valid.

·     Flashing green indicates that the EVDO service is valid.

·     Off indicates no service.

LTE

·     Steady green indicates that the LTE service is valid.

·     Off indicates no LTE service.

GPS

·     Steady green indicates that the GPS service is valid.

·     Off indicates no GPS service.

 

Antennas, interface cables, and the connection methods

For more information about SIC-4G-LTE-M interface module antennas, interface cables, and the connection methods, see "4G interface."

Installing a SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the SIM card fits into the beveled corner of the SIM socket.

 

To install a SIM card:

1.     Open the SIM card socket in the direction marked OPEN so the holder projects upwards.

2.     Insert the SIM card into the SIM card socket along the guide rails.

3.     Close the SIM card socket in the direction marked LOCK to lock the card in position.

4.     Execute the display cellular [ interface-number ] command after the router is started. When "SIM Status = OK" appears in the output information, the SIM card is identified.

SIC-4G-CNDE

Introduction

The SIC-4G-CNDE module provides 4G WLAN access and supports the following technologies:

·     LTE-TDD

·     LTE-FDD

·     TD-SCDMA

·     UMTS

·     GSM

·     EVDO

·     CDMA1x

Interface specifications

Table 76 Interface specifications

Item

Description

Connectors

3 SMA connectors

Supported antenna types

·     GPS

·     Omnidirectional antenna, support for FDD-LTE/TDD-LTE/TD-SCDMA/UMTS/EDGE/GPRS/GSM/EVDO/CDMA

Technologies and supported frequency bands

·     LTE-TDD band 38/39/40/41

·     LTE-FDD band 1/3/5/7/8

·     TD-SCDMA band 34/39

·     UMTS band 1/8

·     GSM band 2/3/5/8

·     EVDO band BC0

·     CDMA1x band BC0

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 49 SIC-4G-CNDE panel

 

Table 77 LED description

LED

Description

WWAN

·     Steady green indicates that a link is present.

·     Fast flashing green indicates that data is being transmitted or received.

·     Slowly flashing green indicates network searching.

·     Off indicates that no link is present.

RSSI

·     Steady green indicates strong signal (RSSI ≥ –69 dBm).

·     Fast flashing green indicates middle signal (–89 dBm ≤ RSSI <–69 dBm).

·     Slowly flashing green indicates low signal (–99 dBm ≤ RSSI < –89 dBm).

·     Steady yellow is reserved for future use.

·     Off indicates weak signal or no signal (RSSI < –99 dBm).

LTE

·     Steady green indicates the 4G-LTE service is valid.

·     Flashing green (8 Hz) indicates the high-speed 3G service such as DC-HSPA+, HSPA+, HSDPA, HSUPA, or EVDO is valid.

·     Steady yellow indicates the 2G or low-speed 3G service such as UMTS, TD-SCDMA, CDMA2000-1xRTT, EDGE, GPRS, or GSM is valid.

·     Flashing yellow is reserved for future use.

·     Off indicates no LTE service.

GPS

·     Steady green indicates that the GPS service is valid.

·     Off indicates no GPS service.

CNDE

·     Steady green indicates that the module is operating correctly and is not sending or receiving data.

·     Flashing green indicates that the module is operating correctly and is sending or receiving data.

·     Steady yellow indicates that the module is faulty.

·     Off indicates that the module is not installed securely, or no power is present.

 

Antennas, interface cables, and the connection methods

For more information about SIC-4G-CNDE interface module antennas, interface cables, and the connection methods, see "4G interface" and "GPS interface."

Installing Micro SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the Micro SIM card is oriented as indicated by the Micro SIM card icon.

 

The SIC-4G-CNDE interface module supports Micro SIM cards.

The SIC-4G-CNDE has two Micro SIM card slots, but only one is active at a time. If you install SIM cards in both slots, the SIM1 slot 1 is active, the SIM2 slot is in standby state by default. To perform an active/standby switchover, execute the sim switch-to command. For more information about the command, see Layer 2—WAN Access Command Reference for the product.

To install a Micro SIM card:

1.     Use a Phillips screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer.

3.     Insert SIM cards into the SIM card slots on the retainer.

4.     Reattach the retainer cover and use the two screws to secure the cover.

5.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the Micro SIM card is identified.

Figure 50 Installing Micro SIM cards

 

RT-SIC-4G-CAT6

IMPORTANT

IMPORTANT:

The RT-SIC-4G-CAT6 module is hot swappable. However, to avoid unexpected reboot of the host, execute the remove command or press the remove button for over 3 seconds and wait for the remove LED to turn off before removing the module.

 

Introduction

The RT-SIC-4G-CAT6 module provides 4G WLAN access and supports the following technologies:

·     LTE-TDD

·     LTE-FDD

·     WCDMA

Interface specifications

Table 78 Interface specifications

Item

Description

Connectors

3 SMA connectors

Standard and operating mode

·     GNSS: GPS/GLONASS/BDS/Galileo

·     Omnidirectional antenna: FDD-LTE, TDD-LTE, WCDMA

Supported services

·     LTE-TDD

·     LTE-FDD

·     WCDMA

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 51 RT-SIC-4G-CAT6 panel

 

Table 79 LED description

LED

Status

Description

WWAN

Steady green

A WWAN link is present.

Fast flashing green

Data is being transmitted or received on the WWAN link.

Slow flashing green

Searching and connecting to a WWAN network.

Off

Not connected to a WWAN.

WCDMA

Steady green

Strong 3G signal strength (RSSI ≥ –70 dBm)

Fast flashing green

Medium 3G signal strength (–100 dBm ≤ RSSI < –70 dBm)

Slow flashing green

Low 3G signal strength (–125 dBm ≤ RSSI < –100 dBm)

Off

No 3G service (RSSI < –125 dBm)

LTE

Steady green

The module is operating in 4G mode and the 4G signal strength is strong (RSSI ≥ –70 dBm).

Fast flashing green

The module is operating in 4G mode and the 4G signal strength is medium (–100 dBm ≤ RSSI < –70 dBm).

Slow flashing green

The module is operating in 4G mode and the 4G signal strength is low (–125 dBm ≤ RSSI < –100 dBm).

Off

No 4G service (RSSI < –125 dBm)

SIM

Steady green

The SIM card in SIM card slot 0 is working.

Steady yellow

The SIM card in SIM card slot 1 is working.

Off

No SIM cards are present in the two SIM card slots.

GNSS

Steady green

Valid GNSS service.

Off

No GNSS service.

REMOVE

Steady green

The module is operating correctly. You can remove it.

Fast flashing green

The module is initializing. You cannot remove it.

Off

You can remove the module if all the other LEDs on the module are also off.

 

Antennas, interface cables, and connection methods

For more information about RT-SIC-4G-CAT6 module antennas, interface cables, and the connection methods, see "4G interface" and "GNSS interface."

Installing Micro SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the Micro SIM card is oriented as indicated by the Micro SIM card icon.

 

The RT-SIC-4G-CAT6 module supports Micro SIM cards.

The RT-SIC-4G-CAT6 has two Micro SIM card slots, but only one is active at a time. If you install SIM cards in both slots, the SIM0 slot is active and the SIM1 slot is in standby state by default. To perform an active/standby switchover, execute the sim switch-to command. For more information about the command, see Layer 2—WAN Access Command Reference for the product.

To install a Micro SIM card:

1.     Use a Phillips screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer.

3.     Insert SIM cards into the SIM card slots on the retainer. Make sure the beveled corner of the Micro SIM card is oriented as indicated by the Micro SIM card icon.

4.     Reattach the retainer cover and use the two screws to secure the cover.

5.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the Micro SIM card is identified.

Figure 52 Installing Micro SIM cards

 

SIC-D4G-CNDE

Introduction

The SIC-D4G-CNDE module provides 4G WLAN access and supports the following technologies:

·     LTE-TDD

·     LTE-FDD

·     TD-SCDMA

·     UMTS

·     GSM

·     EVDO

·     CDMA1x

Interface specifications

Table 80 Interface specifications

Item

Description

Connectors

5 SMA connectors

Supported antenna types

·     GPS

·     Omnidirectional antenna, support for FDD-LTE/TDD-LTE/TD-SCDMA/UMTS/EDGE/GPRS/GSM/EVDO/CDMA

Technologies and supported frequency band

·     LTE-TDD band 38/39/40/41

·     LTE-FDD band 1/3/5/7/8

·     TD-SCDMA band 34/39

·     UMTS band 1/8

·     GSM band 2/3/5/8

·     EVDO band BC0

·     CDMA1x band BC0

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 53 SIC-D4G-CNDE panel

 

Table 81 LED description

LED

Description

WWAN

·     Steady green indicates that a link is present.

·     Fast flashing green indicates that data is being transmitted or received.

·     Slowly flashing green indicates network searching.

·     Off indicates that no link is present.

RSSI

·     Steady green indicates strong signal (RSSI ≥ –69 dBm).

·     Fast flashing green indicates middle signal (–89 dBm ≤ RSSI <–69 dBm).

·     Slowly flashing green indicates low signal (–99 dBm ≤ RSSI < –89 dBm).

·     Steady yellow is reserved for future use.

·     Off indicates weak signal or no signal (RSSI < –99 dBm).

LTE

·     Steady green indicates the 4G-LTE service is valid.

·     Flashing green (8 Hz) indicates the high-speed 3G service such as DC-HSPA+, HSPA+, HSDPA, HSUPA, or EVDO is valid.

·     Steady yellow indicates the 2G or low-speed 3G service such as UMTS, TD-SCDMA, CDMA2000-1xRTT, EDGE, GPRS, or GSM is valid.

·     Flashing yellow is reserved for future use.

·     Off indicates no LTE service.

GPS

·     Steady green indicates that the GPS service is valid.

·     Off indicates no GPS service.

CNDE

·     Steady green indicates that the module is operating correctly and is not sending or receiving data.

·     Flashing green indicates that the module is operating correctly and is sending or receiving data.

·     Steady yellow indicates that the module is faulty.

·     Off indicates that the module is not installed securely, or no power is present.

 

Antennas, interface cables, and the connection methods

For more information about SIC-D4G-CNDE interface module antennas, interface cables, and the connection methods, see "4G interface" and "GPS interface."

Installing Micro SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the Micro SIM card is oriented as indicated by the Micro SIM card icon.

 

The SIC-D4G-CNDE interface module supports Micro SIM cards.

The SIC-D4G-CNDE has two Micro SIM card slots. The two slots can operate simultaneously. The SIM1 slot uses M0 and M1 antenna ports. M0 is the primary antenna port and M1 is the auxiliary antenna port. The SIM2 slot uses M2 and M3 antenna ports. M2 is the primary antenna port and M3 is the auxiliary antenna port. You must connect an antenna to the primary antenna port. An auxiliary antenna only cannot guarantee reliable connectivity. If the primary antenna fails, replace it immediately.

On the SIC-D4G-CNDE interface module, the space between adjacent antenna ports is insufficient for two antennas. To install 4G antennas for two adjacent ports, use a 4G antenna extension cable to connect one of the antennas.

To install a Micro SIM card:

1.     Use a Phillips screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer.

3.     Insert SIM cards into the SIM card slots on the retainer.

4.     Reattach the retainer cover and use the two screws to secure the cover.

5.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the Micro SIM card is identified.

Figure 54 Installing Micro SIM cards

 

5G interface modules

·     RT-SIC-5G

·     RT-SIC-5G-CN

RT-SIC-5G

CAUTION

CAUTION:

Before removing an RT-SIC-5G module, execute the remove command or press and hold the remove button for more than 3 seconds and wait for the remove LED to turn off. The device might reboot unexpectedly if you remove a SIC-5G module with its remove LED on.

 

Introduction

The RT-SIC-5G module provides 5G WLAN access and supports the following technologies:

·     5G NR

·     LTE-A

·     WCDMA

·     FDD-LTE

·     TDD-LTE

Interface specifications

Table 82 Interface specifications

Item

Description

Connectors

4 SMA connectors

Standard and working mode

·     GNSS: GPS/GLONASS/BeiDou/Galileo

·     Omnidirectional antenna, support for WCDMA/FDD-LTE/TDD-LTE/5G NR

Supported service

·     5G/4G/3G networking

·     5G and LTE-A full coverage

·     NSA and SA modes

·     Integrating multi-constellation GNSS receiver for fast and precise positioning in different environments

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 55 RT-SIC-5G panel

 

Table 83 LED description

LED

Status

Description

WWAN

Steady green

A WWAN link is present.

Fast flashing green

Data is being transmitted or received on the WWAN link.

Slow flashing green

Searching and connecting to a WWAN network.

Off

Not connected to a WWAN.

5G

Steady green (SA mode)

Strong 5G signal strength (RSRP ≥ –85 dBm)

Fast flashing green (SA mode)

Medium 5G signal strength (–100 dBm ≤ RSRP < –85 dBm)

Slow flashing green (SA mode)

Low 5G signal strength (–115 dBm ≤ RSRP < –100 dBm)

Steady yellow (NSA mode)

Strong 5G signal strength (RSRP ≥ –85 dBm)

Fast flashing yellow (NSA mode)

Medium 5G signal strength (–100 dBm ≤ RSRP < –85 dBm)

Slow flashing yellow (NSA mode)

Low 5G signal strength (–115 dBm ≤ RSRP < –100 dBm)

Off

No 5G service

LTE

Steady green

The module is operating in 4G mode and the 4G signal strength is strong (RSSI ≥ –70 dBm).

Fast flashing green

The module is operating in 4G mode and the 4G signal strength is medium (–100 dBm ≤ RSSI < –70 dBm).

Slow flashing green

The module is operating in 4G mode and the 4G signal strength is low (–125 dBm ≤ RSSI < –100 dBm).

Steady yellow

The module is operating in 3G mode and the 3G signal strength is strong (RSSI ≥ –70 dBm).

Fast flashing yellow

The module is operating in 3G mode and the 3G signal strength is medium (–100 dBm ≤ RSSI < –70 dBm).

Slow flashing yellow

The module is operating in 3G mode and the 3G signal strength is low (–125 dBm ≤ RSSI < –100 dBm).

Off

No 3G and 4G services.

SIM

Steady green

The SIM card in SIM card slot 1 is working.

Steady yellow

The SIM card in SIM card slot 2 is working.

Off

No SIM cards are present in the two SIM card slots.

GNSS

Steady green

Valid GNSS service.

Off

No GNSS service.

REMOVE

Steady green

The module is operating correctly. You can hot-remove it.

Fast flashing green

The module is initializing. You cannot hot-remove it.

Off

You can remove the module if all the other LEDs on the module are also off.

 

Antennas, interface cables, and the connection methods

For more information about RT-SIC-5G interface module antennas, interface cables, and the connection methods, see "5G interface."

Installing a 5G SIM card

CAUTION

CAUTION:

To avoid damage to the SIM card or the 5G interface module, insert the SIM card into the slot with the cut corner oriented as shown in the illustration.

 

The RT-SIC-5G interface module provides two SIM card slots. You can install one or two SIM cards as required. SIM card 1 is operating by default when two SIM cards are installed on the SIC-5G interface module. In Figure 56, two SIM cards are installed.

To install a 5G SIM card:

1.     Use a screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer, as shown by callout 2 in Figure 56.

3.     Orient the SIM card with the cut corner as shown in the illustration.

4.     Insert the SIM card into the SIM card slot along the guide rails.

5.     Slightly push SIM card edge to secure it into the slot.

6.     Reattach the retainer cover and use the two screws to secure the cover.

7.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the SIM card is identified.

Figure 56 Installing 5G SIM cards

 

RT-SIC-5G-CN

CAUTION

CAUTION:

Before removing an RT-SIC-5G-CN module, execute the remove command or press and hold the remove button for more than 3 seconds and wait for the remove LED to turn off. The device might reboot unexpectedly if you remove a RT-SIC-5G-CN module with its remove LED on.

 

Introduction

The RT-SIC-5G-CN module provides 5G WLAN access and supports the following technologies:

·     5G NR

·     LTE-A

·     WCDMA

·     FDD-LTE

·     TDD-LTE

Interface specifications

Table 84 Interface specifications

Item

Description

Connectors

4 SMA connectors

Standard and working mode

SMA

·     Omnidirectional antenna, support for WCDMA/FDD-LTE/TDD-LTE/5G NR

Supported service

·     5G/4G/3G networking

·     5G and LTE-A full coverage

·     NSA and SA modes

 

 

NOTE:

For information about the frequency bands supported by the interface module, see "Frequency bands for 3G/4G/5G interface modules."

 

Interface LEDs

Figure 57 RT-SIC-5G-CN panel

 

Table 85 LED description

LED

Status

Description

WWAN

Steady green

A WWAN link is present.

Fast flashing green

Data is being transmitted or received on the WWAN link.

Slow flashing green

Searching and connecting to a WWAN network.

Off

Not connected to a WWAN.

5G

Steady green (SA mode)

Strong 5G signal strength (RSRP ≥ –85 dBm)

Fast flashing green (SA mode)

Medium 5G signal strength (–100 dBm ≤ RSRP < –85 dBm)

Slow flashing green (SA mode)

Low 5G signal strength (–115 dBm ≤ RSRP < –100 dBm)

Steady yellow (NSA mode)

Strong 5G signal strength (RSRP ≥ –85 dBm)

Fast flashing yellow (NSA mode)

Medium 5G signal strength (–100 dBm ≤ RSRP < –85 dBm)

Slow flashing yellow (NSA mode)

Low 5G signal strength (–115 dBm ≤ RSRP < –100 dBm)

Off

No 5G service

LTE

Steady green

The module is operating in 4G mode and the 4G signal strength is strong (RSSI ≥ –70 dBm).

Fast flashing green

The module is operating in 4G mode and the 4G signal strength is medium (–100 dBm ≤ RSSI < –70 dBm).

Slow flashing green

The module is operating in 4G mode and the 4G signal strength is low (–125 dBm ≤ RSSI < –100 dBm).

Steady yellow

The module is operating in 3G mode and the 3G signal strength is strong (RSSI ≥ –70 dBm).

Fast flashing yellow

The module is operating in 3G mode and the 3G signal strength is medium (–100 dBm ≤ RSSI < –70 dBm).

Slow flashing yellow

The module is operating in 3G mode and the 3G signal strength is low (–125 dBm ≤ RSSI < –100 dBm).

Off

No 3G and 4G services.

SIM

Steady green

The SIM card in SIM card slot 1 is working.

Steady yellow

The SIM card in SIM card slot 2 is working.

Off

No SIM cards are present in the two SIM card slots.

REMOVE

Steady green

The module is operating correctly. You can hot-remove it.

Fast flashing green

The module is initializing. You cannot hot-remove it.

Off

You can remove the module if all the other LEDs on the module are also off.

 

Antennas, interface cables, and the connection methods

For more information about RT-SIC-5G-CN interface module antennas, interface cables, and the connection methods, see "5G interface."

Installing a 5G SIM card

CAUTION

CAUTION:

To avoid damage to the SIM card and 5G interface module, insert the SIM card into the slot with the cut corner oriented as shown in the illustration.

 

The RT-SIC-5G-CN interface module provides two SIM card slots. You can install one or two SIM cards as required. SIM card 1 is operating by default when two SIM cards are installed on the RT-SIC-5G-CN interface module. In Figure 56, two SIM cards are installed.

To install a 5G SIM card:

1.     Use a screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer, as shown by callout 2 in Figure 56.

3.     Orient the SIM card with the cut corner as shown in the illustration.

4.     Insert the SIM card into the SIM card slot along the guide rails.

5.     Slightly push SIM card edge to secure it into the slot.

6.     Reattach the retainer cover and use the two screws to secure the cover.

7.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the SIM card is identified.

Figure 58 Installing 5G SIM cards

 

Network data encryption modules

·     SIC-CNDE

·     SIC-CNDE-SJK

·     SIC-4G-CNDE-SJK

·     SIC-D4G-CNDE-SJK

SIC-CNDE

Introduction

The SIC-CNDE is a China Network Data Encryption (CNDE) module. The SIC-CNDE provides high performance and reliable data encryption features for routers by using the SM1 mechanism.

Insert SIC-CNDE module in the SIC slot. The main board forwards IP packets and implements VPN with the encryption feature, where SM1 encryption and decryption is implemented by the encryption module.

Interface specifications

Table 86 Interface specifications

Item

Description

Hardware algorithm

Key algorithm:

·     SM1-128

·     SM1-256

 

Interface LEDs

Figure 59 SIC-CNDE panel

 

Table 87 LED description

LED

Description

ACT

·     Flashing: Data is being transmitted or received between the module and the host.

·     Steady green: No data is being transmitted or received.

 

SIC-CNDE-SJK

Introduction

The SIC-CNDE-SJK (CNDE is the acronym of China Network Data Encryption) supports SM1, SM2, and SM4 encryption algorithms and provides high performance and reliable data encryption features for routers.

LEDs

Figure 60 SIC-CNDE-SJK panel

 

Table 88 LED description

LED

Description

CNDE

·     Steady green: The module is operating correctly and is not sending or receiving data.

·     Flashing green: The module is operating correctly and is sending or receiving data.

·     Steady yellow: The module is faulty.

·     Off: The module is not installed securely, or no power is present.

 

SIC-4G-CNDE-SJK

Introduction

The SIC-4G-CNDE-SJK (CNDE is the acronym of China Network Data Encryption) supports SM1, SM2, and SM4 encryption algorithms and provides high performance and reliable data encryption features for routers. The SIC-4G-CNDE-SJK module provides 4G WLAN access and supports the following technologies:

·     LTE-TDD

·     LTE-FDD

·     TD-SCDMA

·     UMTS

·     GSM

·     EVDO

·     CDMA1x

Interface specifications

Table 89 Interface specifications

Item

Description

Connectors

3 × SMA connectors

Supported antenna types

·     GPS antenna

·     Omnidirectional antenna, support for FDD-LTE/TDD-LTE/TD-SCDMA/UMTS/EDGE/GPRS/GSM/EVDO/CDMA

Technologies and supported frequency bands

·     LTE-TDD band 38/39/40/41

·     LTE-FDD band 1/3/5/7/8

·     TD-SCDMA band 34/39

·     UMTS band 1/8

·     GSM band 2/3/5/8

·     EVDO band BC0

·     CDMA1x band BC0

 

Interface LEDs

Figure 61 SIC-4G-CNDE-SJK panel

 

Table 90 LED description

LED

Description

WWAN

·     Steady green: A link is present.

·     Fast flashing: Data is being transmitted or received.

·     Slowly flashing: The module is searching for wireless networks.

·     Off: No link is present.

RSSI

·     Steady green: Strong signal strength (RSSI ≥ –69 dBm).

·     Fast flashing: Middle signal strength (–89 dBm ≤ RSSI <–69 dBm).

·     Slowly flashing green: Low signal strength (–99 dBm ≤ RSSI < –89 dBm).

·     Off: Weak or no signal strength (RSSI < –99 dBm).

LTE

·     Steady green: The 4G-LTE service is running.

·     Flashing green (8 Hz): The high-speed 3G service such as DC-HSPA+, HSPA+, HSDPA, HSUPA, or EVDO is running.

·     Steady yellow: The 2G or low-speed 3G service such as UMTS, TD-SCDMA, CDMA2000-1xRTT, EDGE, GPRS, or GSM is running.

·     Off: No LTE service.

GPS

·     Steady green: The GPS service is running.

·     Off: No GPS service.

CNDE

·     Steady green: The module is operating correctly and is not sending or receiving data.

·     Flashing green: The module is operating correctly and is sending or receiving data.

·     Steady yellow: The module is faulty.

·     Off: The module is not installed securely, or no power is present.

 

Antennas, interface cables, and the connection methods

For more information about SIC-4G-CNDE-SJK interface module antennas, interface cables, and the connection methods, see "4G interface" and "GPS interface."

Installing a Micro SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the Micro SIM card is oriented as indicated by the Micro SIM card icon.

 

The SIC-4G-CNDE-SJK interface module supports Micro SIM cards.

The SIC-4G-CNDE-SJK has two Micro SIM card slots, but only one is active at a time. If you install SIM cards in both slots, the SIM1 slot 1 is active, the SIM2 slot is in standby state by default. To perform an active/standby switchover, execute the sim switch-to command. For more information about the command, see Layer 2—WAN Access Command Reference for the product.

To install a Micro SIM card:

1.     Use a Phillips screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer.

3.     Insert SIM cards into the SIM card slots on the retainer.

4.     Reattach the retainer cover and use the two screws to secure the cover.

5.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the Micro SIM card is identified.

Figure 62 Installing Micro SIM cards

 

SIC-D4G-CNDE-SJK

Introduction

The SIC-D4G-CNDE-SJK (D4G indicates that the module supports two SIM cards that can operate simultaneously; CNDE is the acronym of China Network Data Encryption) supports SM1, SM2, and SM4 encryption algorithms and provides high performance and reliable data encryption features for routers. The SIC-D4G-CNDE-SJK module provides 4G WLAN access and supports the following technologies:

·     LTE-TDD

·     LTE-FDD

·     TD-SCDMA

·     UMTS

·     GSM

·     EVDO

·     CDMA1x

Interface specifications

Table 91 Interface specifications

Item

Description

Connectors

5 SMA connectors

Supported antenna types

·     GPS antenna

·     Omnidirectional antenna, support for FDD-LTE/TDD-LTE/TD-SCDMA/UMTS/EDGE/GPRS/GSM/EVDO/CDMA

Technologies and supported frequency bands

·     LTE-TDD band 38/39/40/41

·     LTE-FDD band 1/3/5/7/8

·     TD-SCDMA band 34/39

·     UMTS band 1/8

·     GSM band 2/3/5/8

·     EVDO band BC0

·     CDMA1x band BC0

 

Interface LEDs

Figure 63 SIC-D4G-CNDE-SJK panel

 

Table 92 LED description

LED

Description

WWAN

·     Steady green: A link is present.

·     Fast flashing green: Data is being transmitted or received.

·     Slowly flashing green: The module is searching for wireless networks.

·     Off: No link is present.

RSSI

·     Steady green: Strong signal strength (RSSI ≥ –69 dBm).

·     Fast flashing green: Middle signal strength (–89 dBm ≤ RSSI <–69 dBm).

·     Slowly flashing green: Low signal strength (–99 dBm ≤ RSSI < –89 dBm).

·     Off: Weak or no signal strength (RSSI < –99 dBm).

LTE

·     Steady green: The 4G-LTE service is running.

·     Flashing green (8 Hz): The high-speed 3G service such as DC-HSPA+, HSPA+, HSDPA, HSUPA, or EVDO is running.

·     Steady yellow: The 2G or low-speed 3G service such as UMTS, TD-SCDMA, CDMA2000-1xRTT, EDGE, GPRS, or GSM is running.

·     Off: No LTE service is running.

GPS

·     Steady green: The GPS service is running.

·     Off: No GPS service is running.

CNDE

·     Steady green: The module is operating correctly and is not sending or receiving data.

·     Flashing green: The module is operating correctly and is sending or receiving data.

·     Steady yellow: The module is faulty.

·     Off: The module is not installed securely, or no power is present.

 

Antennas, interface cables, and the connection methods

For more information about SIC-D4G-CNDE-SJK interface module antennas, interface cables, and the connection methods, see "4G interface" and "GPS interface."

Installing a Micro SIM card

CAUTION

CAUTION:

Make sure the beveled corner of the Micro SIM card is oriented as indicated by the Micro SIM card icon.

 

The SIC-D4G-CNDE-SJK has two Micro SIM card slots. The two slots can operate simultaneously. The SIM1 slot uses M0 and M1 antenna ports. M0 is the primary antenna port and M1 is the auxiliary antenna port. The SIM2 slot uses M2 and M3 antenna ports. M2 is the primary antenna port and M3 is the auxiliary antenna port. You must connect an antenna to the primary antenna port. An auxiliary antenna only cannot guarantee reliable connectivity. If the primary antenna fails, replace it immediately.

On the SIC-D4G-CNDE-SJK interface module, the space between adjacent antenna ports is insufficient for two antennas. To install 4G antennas for two adjacent ports, use a 4G antenna extension cable to connect one of the antennas.

To install a Micro SIM card:

1.     Use a Phillips screwdriver to remove the two screws on the SIM card retainer cover.

2.     Lift the cover up and away from the retainer.

3.     Insert SIM cards into the SIM card slots on the retainer.

4.     Reattach the retainer cover and use the two screws to secure the cover.

5.     Execute the display cellular [ interface-number ] command after the router is started. If "SIM Status = OK" is displayed in the output information, the Micro SIM card is identified.

Figure 64 Installing Micro SIM cards

 

WLAN interface modules

·     SIC-AP220

·     SIC-AP320

SIC-AP220

Introduction

The SIC-AP220 WLAN interface module receives and sends wireless data. Two external antennas can be installed on the module. The module supports the 802.11a/b/g/n/ac standard and can operate on both the 2.4 G and 5G frequency bands.

Interface specifications

Table 93 Interface specifications

Item

Description

Connector type

RJ-45

Number of connectors

Two: one for the FE port and one for the console port

Interface standard

FE port: 802.3/802.3u, 10/100Mbps autosensing, full/half duplex

Console port: RS/EIA-232

Radio interface: Radio 1 operates on the 5 GHz frequency band and supports the 1×1 MIMO technology. Radio 2 operates on the 2.4 GHz frequency band and support the 2×2 MIMO technology.

Cable type

FE port: Standard (straight-through)/cross-over Ethernet cable

Console port: Console cable

 

Interface LEDs

Figure 65 SIC-AP220 panel

 

Table 94 LED description

LED

Description

SYS

·     Steady amber: The module is starting up.

·     Flashing green: Only the 2.4G radio has associated clients.

·     Flashing amber: Only the 5G radio has associated clients.

·     Flashing alternatively between amber and green: Both the 2.4G and 5G radios have associated clients.

 

Interface cables and the connection methods

For more information about Ethernet interface cables and the connection methods, see "Ethernet interface."

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

For more information about WLAN interface cables and the connection methods, see "WLAN interface."

SIC-AP320

Introduction

The SIC-AP320 WLAN interface module receives and sends wireless data. Two external antennas can be installed on the module. The module supports the 802.11a/b/g/n/ac standard and can operate on both the 2.4 G and 5G frequency bands.

Interface specifications

Table 95 Interface specifications

Item

Description

Connector

1 RJ-45 connector for the console port

Interface standard

Console port: RS/EIA-232

Radio interface: Radio 1 operates on the 5 GHz frequency band and supports the 2×2 MIMO technology. Radio 2 operates on the 2.4 GHz frequency band and support the 1×1 MIMO technology.

Cable type

Console cable for the console port

 

Interface LEDs

Figure 66 SIC-AP320 panel

 

Table 96 LED description

LED

Description

SYS

·     Steady amber: The module is starting up.

·     Flashing green: Only the 2.4G radio has associated clients.

·     Flashing amber: Only the 5G radio has associated clients.

·     Flashing alternatively between amber and green: Both the 2.4G and 5G radios have associated clients.

 

Interface cables and the connection methods

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

For more information about WLAN interface cables and the connection methods, see "WLAN interface."

M.2 riser SIC modules

RT-SIC-M2-SATA

CAUTION

CAUTION:

·     The RT-SIC-M2-SATA module is hot swappable. To remove an RT-SIC-M2-SATA module, first press and hold the remove button for a minimum of three seconds. You can remove the module only when the remove LED is turned off. If the remove LED is flashing green, wait for the remove LED to turn off and then remove the module.

·     No M.2 SSD drive is provided with the RT-SIC-M2-SATA module. Purchase one as required.

·     To build a redundant array of independent disks (RAID), install two SSD drives of the same size in two RT-SIC-M2-SATA modules.

 

Introduction

The RT-SIC-M2-SATA module is an M.2 SSD riser SIC module that provides high data availability through RAID. RAID combines multiple physical drives into one logical drive to provide better storage performance and data backup than a single drive.

Module specifications

Table 97 Module specifications

Item

Description

Drive type

M.2 SATA SSD

Drive dimensions (D × W)

80 × 22 mm (3.15 × 0.87 in)

Number of drives

1

RAID level

RAID 1

Theoretical transmission rate

1.5/3/6 Gbps

 

Interface LEDs

Figure 67 RT-SIC-M2-SATA panel

 

Table 98 LED description

LED

Status

Description

PWR

Steady green

The module has normal power input.

Off

The module does not have power input.

SSD

Steady green

A SSD drive is present.

Steady yellow

The SSD drive is damaged.

Off

No SSD drive is present.

ACT

Flashing green (8 Hz)

The system is reading or writing data to the drive.

Off

The system is not reading or writing data to the drive.

REMOVE

Flashing green (8 Hz)

·     The module is being initialized. Pressing the remove button or removing the module is not allowed.

·     A removal operation is being performed.

Steady green

The module is operating correctly. Pressing the remove button to remove the module is allowed.

Off

The module can be removed.

 

Installing an SSD drive on the module

CAUTION

CAUTION:

To use the RT-SIC-M2-SATA module, install an SSD drive in it.

 

To install an SSD drive on the module:

1.     Insert the SSD drive into the M.2 slot on the module at a 45° angle.

2.     Slightly press the SSD drive until it is level with the surface of the connector.

3.     Use a Phillips screwdriver to screw the SSD drive into place.

Figure 68 Installing an SSD drive

 

 


MIM interface modules

CAUTION

CAUTION:

MIM interface modules can be hot-swapped. To install a MIM interface module in an HMIM slot, first attach the MIM to an HMIM adapter and then insert the MIM into the HMIM slot. This can be performed when the device is operating. To remove a MIM interface module during device operation, first execute the remove command.

 

For the modular MSR series routers, a wide range of optional multiple interface modules (MIMs) are available, which provide abundant interfaces, including synchronous/asynchronous serial interface, Ethernet interface, E1/T1, ISDN BRI/PRI, audio interface, and Layer 2 switching interface.

ATM interface modules

·     MIM-1ATM-OC3

MIM-1ATM-OC3

Introduction

The 1-port ATM (Asynchronous Transfer Mode) 155 Mbps optical interface module (MIM-1ATM-OC3) provides ATM interfaces for routers and supports:

·     Two frame formats: SDH STM-1 and SONET OC-3

·     Scrambling in data transmission

·     Both line clock (when working as DTE interface), and internal clock (when working as DCE interface)

·     Three types of test measures, that is, local cell loopback, local payload loopback, and remote loopback.

Interface specifications

Table 99 Interface specifications

Item

Description

Number of interfaces

1

Connector

SFP/LC

Interface standard

SONET OC-3/SDH STM-1

Operating mode

155 Mbps

 

Interface LEDs

Figure 69 MIM-1ATM-OC3 panel

MIM-1ATM-OC3

 

Table 100 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

POS (SDH/SONET) interface modules

·     MIM-1POS

MIM-1POS

Introduction

The 1-port SDH/SONET interface module (MIM-1POS) supports interface rates up to 155.52 Mbps (STM-1/OC-3).

The MIM-1POS can use the protocols such as PPP, Frame Relay and HDLC at the data link layer and IP at the network layer. It allows direct transmission of packets over SONET/SDH. It supports:

·     Various types of transceiver modules.

·     155.52 Mbps fractional interface.

Interface specifications

Table 101 Interface specifications

Item

MIM-1POS

Connector

SFP/LC

Interface standard

SONET OC-3/SDH STM-1

Number of interfaces

1

Interface rate

155.52 Mbps

 

Interface LEDs

Figure 70 MIM-1POS panel

MIM-1POS

 

Table 102 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

E1/T1 interface modules

·     MIM-1E1

·     MIM-2E1

·     MIM-4E1

·     MIM-1E1-F

·     MIM-2E1-F

·     MIM-4E1-F

·     MIM-8E1

·     MIM-8E1-F

·     MIM-2T1

·     MIM-4T1-F

MIM-1E1/MIM-2E1/MIM-4E1/MIM-1E1-F/MIM-2E1-F/MIM-4E1-F

Introduction

·     MIM-1E1/MIM-2E1/MIM-4E1

The 1-/2-/4-port channelized E1/PRI interface module (MIM-1E1/MIM-2E1/MIM-4E1) transmits, receives, and processes E1 data traffic. In addition, you can use the module for other purposes, such as CE1 access and the ISDN PRI function.

·     MIM-1E1-F/MIM-2E1-F/MIM-4E1-F

The MIM-1E1-F/MIM-2E1-F/MIM-4E1-F module is different from the MIM-1E1/MIM-2E1/MIM-4E1 module in the sense that:

¡     The FE1 operating mode supported by the E1-F modules allows only one n No 64 kbps bundle to be formed on each interface, where n = 1 to 31. However, an E1 module allows arbitrary grouping of 31 channels and multiple bundles.

¡     The E1-F modules do not support PRI mode.

Interface specifications

Table 103 Interface specifications

Item

MIM-1E1/1E1-F module

MIM-2E1/2E1-F module

MIM-4E1/4E1-F module

Connector

DB-15

DB-15

DB-25

Number of connectors

1

2

1

Interface standard

·     G.703

·     G.704

Interface rate

2.048 Mbps

Cable type

·     E1 75-ohm unbalanced coaxial cable

·     E1 120-ohm balanced twisted pair cable

·     120-ohm 4E1 conversion cable (MIM-4E1/MIM-4E1-F modules)

·     75-ohm 4E1 conversion cable (MIM-4E1/MIM-4E1-F modules)

·     Coaxial connector, network interface connector and 75-ohm to 120-ohm adapter (with BNC connector)

Operating mode

·     E1, CE1, ISDN PRI (only supported by MIM-1E1/MIM-2E1/MIM-4E1)

·     FE1 (only supported by MIM-1E1-F/MIM-2E1-F/MIM-4E1-F)

Supported service

·     Backup

·     Terminal access service

·     ISDN PRI (only supported by MIM-1E1/MIM-2E1/MIM-4E1)

 

Interface LEDs

MIM-1E1 and MIM-1E1-F panels are similar. The following figure illustrates an MIM-1E1 panel.

Figure 71 MIM-1E1 panel

 

The panels of MIM-2E1 and MIM-2E1-F are similar. The following figure illustrates an MIM-2E1 panel.

Figure 72 MIM-2E1 panel

 

MIM-4E1 and MIM-4E1-F panels are similar. The following figure illustrates an MIM-4E1 module.

Figure 73 MIM-4E1 panel

 

Table 104 LED description

LED

Description

LINK

·     Off: The link is not set up.

·     On: The link has been set up.

ACT

·     Off: No data is being transmitted or received;

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connections methods, see "E1 interface."

MIM-8E1/MIM-8E1-F

Introduction

·     MIM-8E1 module

The 8-port channelized E1/PRI interface module (MIM-8E1) transmits, receives, and processes eight channels of E1 data traffic. In addition, you can use the module for other purposes, such as CE1 access and the ISDN PRI function.

·     MIM-8E1-F module

The 8-port fractional E1 interface module (MIM-8E1-F) is different from the MIM-8E1 module in the sense that:

¡     The FE1 operating mode supported by the MIM-8E1-F module allows only one n No 64 kbps bundle to be formed on each interface, where n = 1 to 31. However, an MIM-8E1 module allows arbitrary grouping of 31 channels and therefore multiple bundles.

¡     The MIM-8E1-F module does not support PRI mode.

 

 

NOTE:

For a MIM-8E1 module, the system automatically creates a serial interface for each timeslot bundle formed on a controller E1 interface.

 

Interface specifications

Table 105 Interface specifications

Item

Description

Connector

D68

Number of connectors

1

Interface standard

G.703

Interface rate

2.048 Mbps

Cable type

75-ohm 8E1 conversion cable

Cable characteristic impedance

75-ohm

Operating mode

·     E1, CE1, ISDN PRI (only supported by MIM-8E1)

·     FE1 (only supported by MIM-8E1-F)

Supported service

·     Backup

·     Terminal access service

·     ISDN PRI (only supported by MIM-8E1)

 

Interface LEDs

MIM-8E1 and MIM-8E1-F panels are similar.

Figure 74 MIM-8E1 (75-ohm) panel

 

Figure 75 MIM-8E1-F (75-ohm) panel

 

Table 106 LED description

LED

Description

LINK

·     Off: The link is not set up.

·     On: The link has been set up.

ACT

·     Off: No data is being transmitted or received;

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connections methods, see "E1 interface."

MIM-2T1/MIM-4T1-F

Introduction

·     MIM-2T1 module

The 2-port channelized T1/PRI interface module (MIM-2T1) serves to transmit/receive and handle T1 data streams, provide CT1 access, and fulfill the function of ISDN PRI. Thereby, one module can be used for multiple purposes.

·     MIM-4T1-F

The 4-port fractional T1 interface module (MIM-4T1-F) provides the following features:

¡     FT1 operating mode supported by T1-F modules allows only one bundle. In other words, the time slots can only be bundled into one n x 64 kbps or 56 kbps channel, where n=1-24.

¡     T1-F does not support PRI mode.

 

 

NOTE:

For a MIM-1T1 module, the system automatically creates a serial interface for each timeslot bundle formed on a controller T1 interface.

 

Interface specifications

Table 107 Interface specifications

Item

Description

Connector

RJ-45

 

Number of connectors

·     2 (MIM-2T1 module)

·     4 (MIM-4T1-F module)

 

Interface standard

·     G.703/T1.102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

 

Interface rate

1.544 Mbps

 

Cable type

T1 cable (100-ohm shielding network cable)

 

Operating mode

·     CT1/ISDN PRI (MIM-2T1 module)

·     FT1 (MIM-4T1-F module)

 

Supported service

·     Backup

·     Terminal access service

·     ISDN PRI (MIM-2T1 module)

 

 

Interface LEDs

Figure 76 MIM-2T1 panel

MIM-2T1

 

Figure 77 MIM-4T1-F panel

 

Table 108 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being transmitted or/and received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

E3/T3 interface modules

·     MIM-1CE3

MIM-1CE3

Introduction

The 1-port channelized E3 interface module (MIM-1CE3) serves to:

·     Transmit/Receive and handle one channel of E3 fast traffic, as well as provide the accessing of E3 traffic when working in E3 mode.

·     Provide the low-speed accessing service at the speed of n No 64 kbps, where n is smaller than or equal to 128, when working in CE3 mode.

 

 

NOTE:

E3 represents the tertiary group rate of E system in the TDM system, that is, 34.368 Mbps. An E3 channel can be channelized into 16 E1 lines through the demultiplexing processes of E23 and E12, each E1 line supporting both the operating modes of E1 and CE1. E23 is used to indicate either E2-to-E3 multiplex or E3-to-E2 demultiplex, and E12 to indicate E1-to-E2 multiplex or E2-to-E1 demultiplex. "E23" and "E12" discussed here represent the demultiplex process.

 

Interface specifications

Table 109 Interface specifications

Item

Description

Connector

SMB

Number of connectors

2

Interface standard

·     G.703

·     G.704

·     G.751

Interface rate

34.368 Mbps

Interface cable type

E3 cable (75ohm coaxial cable)

Operating mode

E3

CE3

Supported service

E3 leased line

 

Interface LEDs

Figure 78 MIM-1CE3 panel

MIM-1CE3

 

Table 110 LED description

LED

Description

LINK

·     Off: The link is not set up.

·     On: The link has been set up.

ACT

·     Off: No data is being transmitted or received;

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about E3 interface cables and the connection methods, see "E3/T3 interface."

Serial interface modules

·     MIM-2SAE

·     MIM-4SAE

·     MIM-8SAE

·     MIM-8ASE

·     MIM-16ASE

MIM-2SAE/MIM-4SAE/MIM-8SAE

Introduction

The MIM-2SAE/MIM-4SAE/MIM-8SAE stands for 2/4/8-port enhanced high-speed synchronous/asynchronous serial interface module. In terms of function, SAE modules are the same as SA modules except that SAE modules support more protocols, for example, RS449, X.21, and RS530.

Interface specifications

Table 111 Interface specifications

Item

Synchronous

Asynchronous

Connector

D28

Number of connectors

2 (MIM-2SAE)

4 (MIM-4SAE)

8 (MIM-8SAE)

Interface standard and operating mode

V.24

V.35, RS449, X.21, RS530

RS-232

DTE, DCE

DTE, DCE

Minimum baud rate

(bps)

1200

1200

300

Maximum baud rate

(bps)

64 k

2.048 M

115.2

Cable

·     V.24 (RS-232) DTE cable

·     V.24 (RS-232) DCE cable

·     V.35 DTE cable

·     V.35 DCE cable

·     X.21 DTE cable

·     X.21 DCE cable

·     RS449 DTE cable

·     RS449 DCE cable

·     RS530 DTE cable

·     RS530 DCE cable

Supported service

·     DDN leased line

·     Terminal access service

·     Dialup through modems

·     Backup

·     Asynchronous leased line

·     Dumb terminal access

 

Interface LEDs

Figure 79 MIM-2SAE panel

MIM-2SAE

 

Figure 80 MIM-4SAE panel

MIM-4SAE

 

Table 112 LED description

LED

Description

LINK

·     Off: No link is present;

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received;

·     Flashing: Data is being received or/and transmitted.

 

Figure 81 MIM-8SAE panel

MIM-8SAE

 

The MIM-8SAE module provides a LED for each channel. When the LED is on, a link is present. When the LED is flashing, data is being transmitted or received.

Interface cables and the connection methods

For more information about synchronous/asynchronous serial port cables and the connection methods, see "Synchronous/asynchronous serial ports."

MIM-8ASE/MIM-16ASE

Introduction

The 8/16-port enhanced asynchronous serial interface module (MIM-8ASE/MIM-16ASE) transmits/receives and handles asynchronous serial interface data streams. ASE modules, however, use RJ-45 connectors and AUX cables.

Interface specifications

Table 113 Interface specifications

Item

MIM-8ASE module

MIM-16ASE module

Connector

RJ-45

Number of connectors

8 (MIM-8ASE)

16 (MIM-16ASE)

Interface standard and operating mode

RS-232

Cable

·     AUX cable

·     Ethernet straight-through cable

·     MIM-8ASE/MIM-16ASE dumb terminal cable

Minimum baud rate (bps)

300

Maximum baud rate (bps)

115.2 k

Service supported

·     Dialup through Modem

·     Backup

·     Terminal access service

·     Asynchronous leased line service

 

Interface LEDs

Figure 82 MIM-8ASE panel

MIM-8ASE

 

Figure 83 MIM-16ASE panel

MIM-16ASE

 

Each channel on the MIM-8ASE/MIM-16ASE has only one LED.

Table 114 LED description

LED

Description

LINK/ACT

·     Off: No link is present;

·     On: A link is present.

·     Flashing: Data is being transmitted or received.

 

Interface cables and the connection methods

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

POS terminal access interface modules

·     MIM-6FCM

MIM-6FCM

Introduction

The 6-port fast connect modem interface module (FIC-6FCM) provides services for point of sale (POS) terminal devices to fast dial up to a bank card accounting system.

 

 

NOTE:

The point of sale (POS) access service refers to a type of smart card service widely used in places such as shopping malls and gasoline service stations. It links a POS terminal device located in a shopping mall or a gasoline service station to a bank card accounting system to provide services.

 

Interface specifications

Table 115 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

6

Cable

Telephone cable with ferrite core

Supported protocols

·     ITU-T-V.22 (PSK/QPSK)

·     V.22 BIS (QAM)

 

Interface LEDs

Figure 84 MIM-6FCM panel

 

Each connector of the POS access port has two LEDs: carrier detect (CD) and ACT.

Table 116 LED description

LED

Description

CD

·     Off: No carrier signals are detected.

·     On: A carrier signal is detected.

ACT

·     Flashing: Data is being received or transmitted.

·     Off: No data is being received or transmitted.

 

Interface cable

The MIM-6FCM uses telephone cables with ferrite core.

 

 

NOTE:

The standard equipment package for the MIM-6FCM includes the appropriate number of interface cables.

 

Connecting the interface cable

CAUTION

CAUTION:

·     Before connecting a port, read its label carefully. A wrong connection might damage the interface module or the device.

·     Add a special lightning arrester at the input end of the telephone cable for better protection.

 

To connect the interface cable:

1.     Connect one end of a telephone cable to the RJ-11 or RJ-45 connector of the FCM interface.

2.     Connect the other end of the telephone cable to the PSTN network.

3.     Check the LED on the MIM-6FCM panel. When the LED is on, the self-test succeeds. The LED is off, the self-test failed. In the latter case, contact your agent.

Upgrading the FCM module software

1.     Download the FCM module software to the CF module or flash of the router.

2.     After the router that is inserted with the FCM module is powered on and starts up, input bootrom update file cfa0:/ filename slot slotnum all in the user mode to upgrade FCM module software.

3.     Run the display version command to display the driver version. If the version number is changed, the upgrade is completed.

The driver version number is just like (Driver) 1.0 in the module information displayed as follows:

[SLOT  5]MIM-6FCM       (Hardware)1.0,   (Driver)1.0,    (Cpld)1.0

Voice interface modules

·     MIM-4FXS

·     MIM-4FXO

·     MIM-8FXS8FXO

·     MIM-16FXS

·     MIM-4E&M

·     MIM-2VE1

·     MIM-2VT1

·     MIM-1VE1

·     MIM-1VT1

MIM-8FXS8FXO

Introduction

The 8-port voice subscriber circuit and 8-port voice AT0 analog trunk interface module (MIM-8FXS8FXO) serves to access and handle 16 channels of analog voice signals over data communication networks. The module provides eight FXS interfaces and eight FXO interfaces:

·     FXS interfaces are analog subscriber line interfaces that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges.

·     FXO interfaces are loop trunk interfaces that provide access of common subscriber lines of exchanges.

 

CAUTION

CAUTION:

While using MIM-8FXS8FXO, make sure the device can be connected to IP networks or other WANs.

 

Interface specifications

Table 117 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

·     8 (FXS interfaces)

·     8 (FXO interfaces)

Interface standard

·     Subscriber circuit interface (FXS) compliant with ITU Q.512.

·     Loop trunk interface (FXO) compliant with ITU Q.552.

·     Over-current and over-voltage protection compliant with ITU K.20.

Cable type

Telephone cable with ferrite core

Dial-up mode

DTMF, compliant with GB3378 (Pulse dial-up is not available.)

Bandwidth

300 to 3400 Hz

 

Interface LEDs

Figure 85 MIM-8FXS8FXO panel

 

Table 118 LED description

LED

Description

LINK/ACT

·     Off: No link is present.

·     Steady green: A link is present and a call connection is being established.

·     Flashing yellow: A link is present and there is a call activity.

 

Interface cables and the connection methods

For more information about FXS/FXO interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

MIM-16FXS

Introduction

The 16-port loop trunk interface module (MIM-16FXS) serves to access and handle 16 channels of analog voice signals over data communication networks. The module provides 16 FXS interfaces:

FXS interfaces are analog subscriber line interfaces that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges.

Interface specifications

Table 119 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

16 (FXS interfaces)

Interface standard

Subscriber circuit interface (FXS) compliant with ITU Q.512.

Over-current and over-voltage protection compliant with ITU K.20.

Cable type

Telephone cable with ferrite core

Dial-up mode

DTMF, compliant with GB3378 (Pulse dial-up is not available.)

Bandwidth

300 to 3400 Hz

 

Interface LEDs

Figure 86 MIM-16FXS panel

MIM-16FXS+口

 

Table 120 LED description

LED

Description

LINK/ACT

·     Off: No link is present.

·     Steady green: A link is present and a call connection is being established.

·     Flashing yellow: A link is present and there is a call activity.

 

Interface cables and the connection methods

For more information about FXS interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

MIM-2VE1

Introduction

The 2-port E1 voice interface module (MIM-2VE1) handles dense voice signals in a VoIP system. It provides two CE1/PRI/R2 ports, allowing the access of 60 channels of voice signals.

Interface specifications

Table 121 Interface specifications

Item

Description

Connector

D15

Number of connectors

2

Operating mode

CE1

ISDN PRI

R2

Interface rate

2.048 Mbps

Cable

E1 120-ohm balanced twisted pair cable

75ohm-to-120ohm adapter

Supported service

·     R2 signaling

·     DSS1 signaling

·     IP Fax

·     General VoIP features in Comware

 

Interface LEDs

Figure 87 MIM-2VE1 panel

 

Table 122 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received on the interface.

·     Flashing: Data is being transmitted and/or received.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

MIM-2VT1

Introduction

The 2-port T1 voice interface module (MIM-2VT1) can handle dense voice signals in VoIP system. It provides two CT1/PRI ports, allowing the access of 48 channels of voice signals.

Interface specifications

Table 123 Interface specifications

Item

Description

Connector

RJ-45

Number of connector

2

Interface standard

·     G.703/T1.102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm standard shielded cable)

Operation mode

·     CT1

·     ISDN PRI

Services

·     Backup

·     Terminal access

·     ISDN

 

Interface LEDs

Figure 88 MIM-2VT1 panel

 

Table 124 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received on the interface.

·     Flashing: Data is being transmitted and/or received.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

MIM-1VE1

Introduction

The 1-port E1 voice interface module (MIM-1VE1) can handle dense voice signals in VoIP system. It provides a CE1/PRI/R2 port, allowing the access of 30 channels of voice signals.

Interface specifications

Table 125 Interface specifications

Item

Description

Connector

D15

Number of connectors

1

Operating mode

CE1

ISDN PRI

R2

Interface rate

2.048 Mbps

Cable

E1 120-ohm balanced twisted pair cable

75-ohm-to-120-ohm adapter (with BNC connector)

Supported service

·     R2 signaling

·     DSS1 signaling

·     IP Fax

·     General VoIP features in Comware

 

Interface LEDs

Figure 89 MIM-1VE1 panel

 

Table 126 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received on the interface.

·     Flashing: Data is being transmitted and/or received.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

MIM-1VT1

Introduction

The 1-port T1 voice interface module (MIM-1VT1) can handle dense voice signals in VoIP system.

The MIM-1VT1 module is structured in the form of board plus VCPM module plus VPM strip. It provides a CT1/PRI port, allowing the access of 24 channels of voice signals.

Interface specifications

Table 127 Interface specifications

Item

Description

Connector

RJ-45

Number of connector

1

Interface standard

·     G.703/T1.102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm standard shielded cable)

Operation mode

CT1

ISDN PRI

Services

Backup

Terminal access

ISDN

 

Interface LEDs

Figure 90 MIM-1VT1 panel

 

Table 128 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received on the interface.

·     Flashing: Data is being transmitted and/or received.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

MIM-4FXS/MIM-4FXO

Introduction

·     The 4-port voice subscriber circuit interface module (MIM-4FXS) serves to access and handle 4 channels of ordinary analog phone, fax, or AT0 loop trunk of telephone exchange.

·     The 4-port voice AT0 analog trunk interface module (MIM-4FXO) serves to access and handle 4 channels of common user lines of telephone exchange.

These modules make it possible to transfer voice signals over data communication networks.

Interface specifications

Table 129 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

4

Cable

·     Telephone cable with ferrite core

·     E&M trunk (for E&M module, which should be made by users depending on the actual needs at the site.)

Interface standard

·     ITU Q.512-compliant subscriber circuit interface (MIM-4FXS)

·     ITU Q.552-compliant loop trunk interface (MIM-4FXO)

·     ITU K.20-compliant overcurrent and overvoltage protection

Dial-up mode

DTMF (Dual-Tone Multi-Frequency) but not pulse dial-up

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 91 MIM-4FXS panel

MIM-4FXS

 

Figure 92 MIM-4FXO panel

MIM-4FXO+口

 

Table 130 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: The channel is idle.

·     On: There is call activity.

 

Interface cables and the connection methods

For more information about FXS/FXO interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

MIM-4E&M

Introduction

The 4-port voice E&M analog trunk interface module (MIM-4E&M) serves to access and handle 2/4 channels of E&M analog trunks.

These modules make it possible to transfer voice signals over data communication networks.

Interface specifications

Table 131 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

4

Cable

·     Telephone cable with ferrite core

·     E&M trunk (for E&M module, which should be made by users depending on the actual needs at the site.)

Interface standard

·     G.712-compliant E&M trunk interface, E&M interface (supporting Bell type I, II, III, V, and support 4-wire).

·     ITU K.20-compliant overcurrent and overvoltage protection

Dial-up mode

DTMF (Dual-Tone Multi-Frequency) but not pulse dial-up

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 93 MIM-4E&M panel

MIM-4EM+口

 

Table 132 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: The channel is idle.

·     On: There is call activity.

 

Interface cables and the connection methods

For more information about E&M interface cables and the connection methods, see "E&M interface."

 


HMIM/DHMIM interface modules

CAUTION

CAUTION:

·     HMIM interface modules can be hot-swapped. To remove a HMIM when the device is operating, first execute the remove command or press the remove button. If you fail to do so, the device might reboot unexpectedly. For the specific operation instructions, see the description for the HMIM interface module. The remove command and the remove button cannot be used simultaneously, as this might cause the HMIM interface module to become unusable.

·     DHMIM interface modules can be hot-swapped. To remove a DHMIM when the device is operating, first execute the remove command.

 

For the modular MSR series routers, a wide range of optional high-performance multiplex interface modules (HMIMs) and double high-performance multiplex interface modules (DHMIMs) are available, which provide abundant interfaces, including synchronous/asynchronous serial interface, Ethernet interface, E1/T1, ISDN BRI/PRI, audio interface, and Layer 2 switching interface.

Ethernet switching modules

·     HMIM-8GSW

·     HMIM-24GSW

·     HMIM-24GSW-PoE

·     HMIM-8GSWF

HMIM-8GSW/HMIM-24GSW/HMIM-24GSW-PoE

Introduction

The HMIM-8GSW/HMIM-24GSW/HMIM-24GSW-PoE module is an 8/24/24 1000 Mbps Ethernet Layer 2 switching HMIM interface module. Each HMIM-8GSW/HMIM-24GSW module provides 8/24 1000 Mbps RJ-45 ports. HMIM-8GSW/HMIM-24GSW modules are suitable for a small enterprise network to act as a switching and routing device, which can be directly connected to PCs and network devices of the enterprise. The HMIM-24GSW-PoE can supply power to remote PDs.

The HMIM-8GSW/HMIM-24GSW/HMIM-24GSW-PoE supports the following functions:

·     A transmission distance of 100 m (328.08 ft) over a category-5 twisted pair cable (crossover or straight-through cable).

·     1000 Mbps wire-speed forwarding between any two ports connected with a category-5 twisted pair cable (crossover or straight-through cable).

·     Autosensing at a rate of 10 Mbps, 100 Mbps, or 1000 Mbps.

·     Full duplex (typically used) and half duplex operating modes.

Interface specifications

Table 133 describes the interface specifications of the HMIM-8GSW, HMIM-24GSW, and HMIM-24GSW-PoE interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 133 Interface specifications

Item

Description

Connector type

RJ-45

Interface type

MDI/MDIX

Number of connectors

·     8 (HMIM-8GSW)

·     24 (HMIM-24GSW and HMIM-24GSW-PoE)

Cable type

Standard (straight-through) Ethernet cable/crossover Ethernet cable

Operation mode

Autosensing 10/100/1000 Mbps, full duplex/half duplex

 

 

NOTE:

Ethernet interfaces on network adapters are usually medium dependent interfaces (MDIs). Cross medium dependent interfaces (MDIXs) are another type of Ethernet interfaces, which are usually used on hubs and LAN Switches.

 

Interface LEDs

Figure 94 HMIM-8GSW panel

 

Figure 95 HMIM-24GSW panel

Figure 96 HMIM-24GSW-PoE panel

 

Each 1000 Mbps Ethernet interface on the panel has one LED.

Table 134 LED description

LED status

Description

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Steady yellow

A 10/100 Mbps link is present.

Flashing yellow

The port is sending and receiving data at 10/100 Mbps.

 

Interface cables and the connection methods

For more information about the Ethernet interface cables and the connection methods, see "Ethernet interface."

HMIM-8GSWF

Introduction

The 8-port 100/1000 Mbps Ethernet Layer 2/Layer 3 HMIM interface module HMIM-8GSWF provides four SFP fiber ports and four combo interfaces. It is designed for a switching/routing integrated device on a small-sized enterprise network. You can connect it to network devices inside the network.

Functions supported by interface modules are as follows:

·     Various types of transceiver modules.

·     Operating speeds of 1000 Mbps and 100 Mbps.

·     Full duplex operating mode.

Interface specifications

Table 135 describes the interface specifications of the HMIM-8GSWF interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 135 Interface specifications

Item

Description

Number of ports

8

Connector type

SFP/LC/RJ-45

Interface standard

·     802.3

·     802.3u

·     802.3ab

Operation mode

100/1000 Mbps, full duplex

 

Interface LEDs

Figure 97 HMIM-8GSWF panel

 

Table 136 SFP fiber port LED description

LED status

Description

Off

No link is present.

Steady green

A 1000 Mbps link is present.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Steady yellow

A 100 Mbps link is present.

Flashing yellow

The port is sending and receiving data at 100 Mbps.

 

Table 137 RJ-45 port LED description

LED

Description

Green LED

·     Off: No link is present.

·     On: A 1000 Mbps link is present.

·     Flashing: The port is sending and receiving data at 1000 Mbps.

Yellow LED

·     Off: No link is present.

·     On: A100 Mbps link is present.

·     Flashing: The port is sending and receiving data at 100 Mbps.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

Ethernet interface modules

·     HMIM-2GEE

·     HMIM-4GEE

·     HMIM-8GEE

·     RT-HMIM-4GEE-V2

·     RT-HMIM-8GEE-V2

·     HMIM-2GEF

·     HMIM-4GEF

·     HMIM-8GEF

·     RT-HMIM-4GEF-V2

·     RT-HMIM-8GEF-V2

·     RT-HMIM-4XP

HMIM-2GEE/HMIM-4GEE/HMIM-8GEE

Introduction

The HMIM-GEE module is used to complete the communication between a router and a LAN, which includes the following types:

·     HMIM-2GEE2-port 10BASE-T/100BASE-TX/1000BASE-T Ethernet copper interface module

·     HMIM-4GEE4-port 10BASE-T/100BASE-TX/1000BASE-T Ethernet copper interface module

·     HMIM-8GEE8-port 10BASE-T/100BASE-TX/1000BASE-T Ethernet copper interface module

The HMIM-2GEE/HMIM-4GEE/HMIM-8GEE supports:

·     100 m (328.08 ft) of transmission distance over a category-5 twisted-pair cable.

·     Operation at 10/100/1000 Mbps and autosensing.

·     Full duplex and half-duplex, autonegotiation.

Interface specifications

Table 138 describes the interface specifications of the HMIM-2GEE, HMIM-4GEE, and HMIM-8GEE interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 138 Interface specifications

Item

HMIM-2GEE

HMIM-4GEE

HMIM-8GEE

Connector type

RJ-45

Number of connectors

2

4

8

Interface type

MDI/MDIX

Interface standard

·     802.3

·     802.3u

·     802.3ab

Supported cable

Ethernet cable

Operating mode

·     10/100/1000 Mbps, autosensing

·     Full duplex/half-duplex, autonegotiation

 

Interface LEDs

Figure 98 HMIM-2GEE panel

 

Figure 99 HMIM-4GEE panel

 

Figure 100 HMIM-8GEE panel

 

Table 139 LED description

LED

Description

Green LED

·     Off: No link is present.

·     On: A 1000 Mbps link is present.

·     Flashing: The port is sending and receiving data at 1000 Mbps.

Yellow LED

·     Off: No link is present.

·     On: A 10/100 Mbps link is present.

·     Flashing: The port is sending and receiving data at 10/100 Mbps.

 

Interface cables and the connection methods

For more information about the Ethernet interface cables and the connection methods, see "Ethernet interface."

RT-HMIM-4GEE-V2/RT-HMIM-8GEE-V2

CAUTION

CAUTION:

The RT-HMIM-4GEE-V2/RT-HMIM-8GEE-V2 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The 4/8-port 10Base-T/100Base-TX/1000Base-T Ethernet copper interface module (RT-HMIM-4GEE-V2/RT-HMIM-8GEE-V2) is used to complete the communication between a router and a LAN.

The RT-HMIM-4GEE-V2/RT-HMIM-8GEE-V2 supports:

·     100 m (328.08 ft) of transmission distance over a category-5 twisted-pair cable.

·     Operation at 10/100/1000 Mbps and autosensing.

·     Full duplex and half-duplex, autonegotiation.

Interface specifications

Table 140 describes the interface specifications of the RT-HMIM-4GEE-V2 and RT-HMIM-8GEE-V2 interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 140 Interface specifications

Item

RT-HMIM-4GEE-V2

RT-HMIM-8GEE-V2

Connector type

RJ-45

Number of connectors

4

8

Interface type

MDI/MDIX

Interface standard

·     802.3

·     802.3u

·     802.3ab

Supported cable

Ethernet cable

Operating mode

·     10/100/1000 Mbps, autosensing

·     Full duplex/half-duplex, autonegotiation

 

Interface LEDs

Figure 101 RT-HMIM-4GEE-V2 panel

 

Figure 102 RT-HMIM-8GEE-V2 panel

 

Table 141 LED description

LED

Status

Description

LINK/ACT

Green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Yellow

A 10/100 Mbps link is present on the port.

Flashing yellow

The port is sending and receiving data at 10/100 Mbps.

Off

No link is present on the port.

RUN

Steady green

The interface module is operating correctly. You cannot remove it.

Off

The interface module is not recognized and you can remove it, or the interface module has been removed.

 

Interface cables and the connection methods

For more information about the Ethernet interface cables and the connection methods, see "Ethernet interface."

RT-HMIM-4GEE-V2-G/RT-HMIM-8GEE-V2-G

CAUTION

CAUTION:

The RT-HMIM-4GEE-V2-G/RT-HMIM-8GEE-V2-G module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The 4/8-port 10Base-T/100Base-TX/1000Base-T Ethernet copper interface module (RT-HMIM-4GEE-V2-G/RT-HMIM-8GEE-V2-G) is used to complete the communication between a router and a LAN.

The RT-HMIM-4GEE-V2-G/RT-HMIM-8GEE-V2-G supports:

·     100 m (328.08 ft) of transmission distance over a category-5 twisted-pair cable.

·     Operation at 10/100/1000 Mbps and autosensing.

·     Full duplex and half-duplex, autonegotiation.

Interface specifications

Table 142 describes the interface specifications of the RT-HMIM-4GEE-V2-G and RT-HMIM-8GEE-V2-G interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 142 Interface specifications

Item

RT-HMIM-4GEE-V2-G

RT-HMIM-8GEE-V2-G

Connector type

RJ-45

Number of connectors

4

8

Interface type

MDI/MDIX

Interface standard

·     802.3

·     802.3u

·     802.3ab

Supported cable

Ethernet cable

Operating mode

·     10/100/1000 Mbps, autosensing

·     Full duplex/half-duplex, autonegotiation

 

Interface LEDs

Figure 103 RT-HMIM-4GEE-V2-G panel

 

Figure 104 RT-HMIM-8GEE-V2-G panel

 

Table 143 LED description

LED

Status

Description

LINK/ACT

Green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Yellow

A 10/100 Mbps link is present on the port.

Flashing yellow

The port is sending and receiving data at 10/100 Mbps.

Off

No link is present on the port.

RUN

Steady green

The interface module is operating correctly. You cannot remove it.

Off

The interface module is not recognized and you can remove it, or the interface module has been removed.

 

Interface cables and the connection methods

For more information about the Ethernet interface cables and the connection methods, see "Ethernet interface."

HMIM-2GEF/HMIM-4GEF/HMIM-8GEF

Introduction

The HMIM-GEF module is used to complete the communication between a router and a LAN, which includes the following types:

·     HMIM-2GEF2-port 1000BASE-SX/1000BASE-LX Ethernet fiber interface module

·     HMIM-4GEF4-port 1000BASE-SX/1000BASE-LX Ethernet fiber interface module

·     HMIM-8GEF8-port 1000BASE-SX/1000BASE-LX Ethernet fiber interface module

The HMIM-2GEF/HMIM-4GEF/HMIM-8GEF supports:

·     Various types of transceiver modules.

·     Operation at 1000 Mbps.

·     Full duplex.

Interface specifications

Table 144 describes the interface specifications of the HMIM-2GEF, HMIM-4GEF, and HMIM-8GEF interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 144 Interface specifications

Item

HMIM-2GEF

HMIM-4GEF

HMIM-8GEF

Number of connectors

2

4

8

Connector type

SFP/LC

Interface standard

·     802.3

·     802.3u

·     802.3ab

Operating mode

·     1000 Mbps

·     Full duplex

 

Interface LEDs

Figure 105 HMIM-2GEF panel

 

Figure 106 HMIM-4GEF panel

 

Figure 107 HMIM-8GEF panel

 

Table 145 LED description

Status

Description

Steady green

A 1000 Mbps link is present.

Flashing green

Data is being transmitted and/or received at 1000 Mbps.

Steady yellow

A 100 Mbps link is present.

Flashing yellow

Data is being transmitted and/or received at 100 Mbps.

Off

No link is present on the port.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

RT-HMIM-4GEF-V2/RT-HMIM-8GEF-V2

CAUTION

CAUTION:

The RT-HMIM-4GEF-V2/RT-HMIM-8GEF-V2 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The 4/8-port 1000Base-SX/1000Base-LX Ethernet fiber interface module (RT-HMIM-4GEF-V2/RT-HMIM-8GEF-V2) is used to complete the communication between a router and a LAN.

The RT-HMIM-4GEF-V2/RT-HMIM-8GEF-V2 supports:

·     Various types of transceiver modules.

·     Operation at 1000 Mbps.

·     Full duplex.

Interface specifications

Table 146 describes the interface specifications of the RT-HMIM-4GEF-V2 and RT-HMIM-8GEF-V2 interface modules. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 146 Interface specifications

Item

RT-HMIM-4GEF-V2

RT-HMIM-8GEF-V2

Number of connectors

4

8

Connector type

SFP/LC

Interface standard

·     802.3

·     802.3u

·     802.3ab

Operating mode

·     1000 Mbps

·     Full duplex

 

Interface LEDs

Figure 108 RT-HMIM-4GEF-V2 panel

 

Figure 109 RT-HMIM-8GEF-V2 panel

 

Table 147 LED description

LED

Status

Description

LINK/ACT

Green

A 1000 Mbps link is present on the port.

Flashing green

The port is sending and receiving data at 1000 Mbps.

Yellow

A 100 Mbps link is present on the port.

Flashing yellow

The port is sending and receiving data at 100 Mbps.

Off

No link is present on the port.

RUN

Steady green

The interface module is operating correctly. You cannot remove it.

Off

The interface module is not recognized and you can remove it, or the interface module has been removed.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

RT-HMIM-4XP

CAUTION

CAUTION:

The RT-HMIM-4XP interface module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The RT-HMIM-4XP is a 10GBASE-R Ethernet interface module that provides four SFP+ ports. Each port is a Layer 3 service port. The RT-HMIM-4XP module supports SFP transceiver modules and 10 Gbps SFP+ transceiver modules.

Interface specifications

Table 148 describes the interface specifications of the RT-HMIM-4XP interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 148 Interface specifications

Item

Description

Number of interfaces

4

Connector

SFP+/LC

Interface standard

10GBASE-R

Interface rate and duplex mode

1000 Mbps/10 Gbps autosensing, full duplex

 

Interface LEDs

Figure 110 RT-HMIM-4XP panel

 

Table 149 LED description

LED

Status

Description

RUN

Steady green

The interface module is operating correctly.

Off

The interface module has not been recognized or is not present.

You can remove the module when the RUN LED is off.

LINK/ACT

Steady green

A 10 Gbps link is present on the port.

Flashing green (12 Hz)

Data is being transmitted and/or received at 10 Gbps on the port.

Steady yellow

A 1000 Mbps link is present on the port.

Flashing yellow (12 Hz)

Data is being transmitted and/or received at 1000 Mbps on the port.

Off

No link is present on the port.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

ATM interface modules

·     HMIM-1ATM-OC3

HMIM-1ATM-OC3

Introduction

The 1-port ATM (Asynchronous Transfer Mode) 155 Mbps optical interface module (HMIM-1ATM-OC3) provides ATM interfaces for routers and supports the following features:

·     Two frame formats: SDH STM-1 and SONET OC-3

·     Scrambling in data transmission

·     Both line clock (when working as DTE interface), and internal clock (when working as DCE interface)

·     Three types of test measures: local cell loopback, local payload loopback, and remote loopback.

Interface specifications

Table 150 Interface specifications

Item

Description

Number of interfaces

1

Connector

SFP/LC

Interface standard

·     SONET OC-3

·     SDH STM-1

Operating mode

155 Mbps

 

Interface LEDs

Figure 111 HMIM-1ATM-OC3 panel

 

Table 151 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm is present.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

POS (SDH/SONET) interface modules

·     HMIM-1POS

·     RT-HMIM-2POS-STM1

·     RT-HMIM-4POS-STM1/4

HMIM-1POS

Introduction

The 1-port SDH/SONET interface module (HMIM-1POS) supports interface rates up to 155.52 Mbps (STM-1/OC-3).

The HMIM-1POS can use the protocols such as PPP, Frame Relay, and HDLC at the data link layer and IP at the network layer. It allows direct transmission of packets over SONET/SDH.

The HMIM-1POS provides 155.52 Mbps fractional interface and supports various types of transceiver modules.

Interface specifications

Table 152 Interface specifications

Item

Description

Interface standard

SONET OC-3/SDH STM-1

Number of interfaces

1

Connector type

SFP/LC

Interface rate

155.52 Mbps

 

Interface LEDs

Figure 112 HMIM-1POS front panel

 

Table 153 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm is present.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

RT-HMIM-2POS-STM1

CAUTION

CAUTION:

The RT-HMIM-2POS-STM1 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The RT-HMIM-2POS-STM1 2-port SDH/SONET interface module provides an interface transmission rate of 155.52 Mbps (STM-1/OC-3).

The RT-HMIM-2POS-STM1 module supports the PPP, Frame Relay, and HDLC protocols at the data link layer and the IP protocol at the network layer. It allows direct transmission of packets over SONET/SDH.

The RT-HMIM-2POS-STM1 module provides 155.52 Mbps fractional interface and supports various types of transceiver modules.

Interface specifications

Table 154 Interface specifications

Item

Description

Interface standard

SONET OC-3/SDH STM-1

Number of interfaces

2

Connector type

SFP/LC

Interface rate

155.52 Mbps

 

Interface LEDs

Figure 113 RT-HMIM-2POS-STM1 front panel

 

Table 155 LED description

LED

Status

Description

ACT/ALM

Steady green

A 155.52 Mbps link is present on the port.

Flashing green

Data is being transmitted and/or received at 155.52 Mbps on the port.

Steady red

An alarm has occurred on the port.

Off

No transceiver module is present on the port or the port is in shutdown state.

RUN

Steady green

The interface module is operating correctly. You cannot remove it.

Flashing green

The interface module is upgrading firmware.

Steady red

The interface module is faulty.

Off

The interface module has not been recognized or is not present.

You can remove the module when the RUN LED is off.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

RT-HMIM-4POS-STM1/4

CAUTION

CAUTION:

The RT-HMIM-4POS-STM1/4 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The RT-HMIM-4POS-STM1/4 4-port SDH/SONET interface module provides an interface transmission rate of 155.52 Mbps (STM-1/OC-3) or 622.08 Mbps (STM-4/OC-12).

The RT-HMIM-4POS-STM1/4 module supports the PPP, Frame Relay, and HDLC protocols at the data link layer and the IP protocol at the network layer. It allows direct transmission of packets over SONET/SDH.

You can execute the speed command to configure the POS ports on the RT-HMIM-4POS-STM1/4 module to operate at STM-1/OC-3 POS or STM-4/OC-12 POS mode. The operation mode configuration applies to the ports rather than the whole interface module.

Interface specifications

Table 156 Interface specifications

Item

Description

Interface standard

·     SONET OC-3/SDH STM-1

·     SONET OC-12/SDH STM-4

Number of interfaces

4

Connector type

SFP/LC

Interface rate

·     155.52 Mbps

·     622.08 Mbps

 

Interface LEDs

Figure 114 RT-HMIM-4POS-STM1/4 front panel

 

Table 157 LED description

LED

Status

Description

ACT/ALM

Steady green

A 155.52 or 622.08 Mbps link is present on the port.

Flashing green

Data is being transmitted and/or received at 155.52 or 622.08 Mbps on the port.

Steady red

An alarm has occurred on the port.

Off

No transceiver module is present on the port or the port is in shutdown state.

RUN

Steady green

The interface module is operating correctly. You cannot remove it.

Flashing green

The interface module is upgrading firmware.

Steady red

The interface module is faulty.

Off

The interface module has not been recognized or is not present.

You can remove the module when the RUN LED is off.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

CPOS (SDH/SONET) interface modules

·     HMIM-1CPOS

·     HMIM-2CPOS

HMIM-1CPOS/HMIM-2CPOS

Introduction

The HMIM-1CPOS/HMIM-2CPOS is a 1-port/2-port channelized SDH/SONET interface module. C stands for channelized, and POS for Packet over SDH/SONET. The HMIM-1CPOS/HMIM-2CPOS provides one/two STM-1/OC3-compliant multi-channel interfaces and supports communication speeds up to 155.52 Mbps.

HMIM-1CPOS/HMIM-2CPOS can change between the E1 system and T1 system.

HMIM-1CPOS is inserted in an HMIM slot of a modular router and communicates with the CPU through the PCI interface to receive and transmit data on STM-1 channelized POS interface. It supports:

·     Various types of transceiver modules.

·     Clear channel (unframed) E1 or T1

·     Fractional (framed) E1 or T1

·     Up to 256 64 kbps logical channels

Interface specifications

Table 158 Interface specifications

Item

Description

Connector

SFP/LC

Number of Connectors

1

Interface standard

SONET OC-3/SDH STM-1

Interface rate

155.52 Mbps

 

IMPORTANT

IMPORTANT:

If the interface receives signal over a long-haul optical fiber, make sure the transmission distance is longer than 25 km (15.53 miles). If the transmission distance is shorter than 25 km (15.53 miles), use an optical attenuator to reduce the optical power.

 

Interface LEDs

Figure 115 HMIM-1CPOS front panel

 

Figure 116 HMIM-2CPOS front panel

 

Table 159 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm is present.

 

Transceiver modules, optical fibers, and connection methods

For more information about transceiver modules, optical fibers, and the connection methods, see "Fiber port."

Interface mode switchover

You can switch the HMIM-1CPOS/HMIM-2CPOS to operate in E1 and T1 interface modes at the command line interface (CLI).

To switch the interface mode:

1.     Insert the HMIM-1CPOS/HMIM-2CPOS into the HMIM slot of the router and then power on the router.

2.     Use the card-mode command in system view to set the interface mode. The HMIM-1CPOS/HMIM-2CPOS module is inserted in slot 4 of the router in the following example.

# Enter system view.

<Sysname> system-view

# Set the HMIM-1CPOS/HMIM-2CPOS to operate in E1 interface mode.

[Sysname] module-mode slot 4 e1

# Set the HMIM-1CPOS/HMIM-2CPOS to operate in T1 interface mode.

[Sysname] module-mode slot 4 t1

E1/T1 interface modules

·     HMIM-1E1

·     HMIM-2E1

·     HMIM-4E1

·     HMIM-1E1-F

·     HMIM-2E1-F

·     HMIM-4E1-F

·     HMIM-8E1(75)

·     HMIM-8E1(75)-F

·     RT-HMIM-2E1-V3

·     RT-HMIM-4E1-V3

·     RT-HMIM-8E1-V3

·     HMIM-2T1

·     HMIM-4T1-F

·     HMIM-2E1T1

·     HMIM-4E1T1

·     HMIM-8E1T1

·     HMIM-2E1T1-F

·     HMIM-4E1T1-F

·     HMIM-8E1T1-F

HMIM-1E1/HMIM-2E1/HMIM-4E1/HMIM-1E1-F/HMIM-2E1-F/HMIM-4E1-F

Introduction

The 1-port channelized E1/PRI interface module (HMIM-1E1), 2-port channelized E1/PRI interface module (HMIM-2E1), and 4-port channelized E1/PRI interface module (HMIM-4E1) transmit, receive, and process E1 data traffic. In addition, you can use these modules for other purposes, such as CE1 access and the ISDN PRI function.

The HMIM-1E1-F/HMIM-2E1-F/HMIM-4E1-F module is different from the HMIM-1E1/HMIM-2E1/HMIM-4E1 module in the sense that:

·     The FE1 operating mode supported by the E1-F modules allows only one n No 64 Kbps bundle to be formed on each interface, where the value range of n is 1 to 31. However, an E1 module allows arbitrary grouping of 31 channels and multiple bundles.

·     The E1-F modules do not support PRI mode.

Interface specifications

Table 160 Interface specifications

Item

HMIM-1E1/HMIM-1E1-F

HMIM-2E1/HMIM-2E1-F

HMIM-4E1/HMIM-4E1-F

Connector type

DB15

DB15

DB25

Number of connectors

1

2

1

Interface standard

G.703 and G.704

Interface rate

2.048 Mbps

Cable type

·     E1 75-ohm unbalanced coaxial cable

·     E1 120-ohm balanced twisted pair cable

·     120-ohm 4E1 conversion cable (only supported by the HMIM-4E1/HMIM-4E1-F)

·     75-ohm 4E1 conversion cable (only supported by the HMIM-4E1/HMIM-4E1-F)

·     Coaxial connector, network interface connector, and 75-ohm to 120-ohm adapter (with BNC connector)

Operating mode

·     E1, CE1, ISDN PRI (only supported by the HMIM-1E1/HMIM-2E1/HMIM-4E1)

·     FE1 (only supported by the HMIM-1E1-F/HMIM-2E1-F/HMIM-4E1-F)

Supported services

·     Backup

·     Terminal access service

·     ISDN PRI (only supported by the HMIM-1E1/HMIM-2E1/HMIM-4E1)

 

Interface LEDs

Figure 117 HMIM-E1 panel

 

Figure 118 HMIM-E1-F panel

 

Figure 119 HMIM-2E1 panel

 

Figure 120 HMIM-2E1-F panel

 

Figure 121 HMIM-4E1 panel

 

Figure 122 HMIM-4E1-F panel

 

Table 161 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

LINK

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

ACTIVE

·     Off: No data is being transmitted or received.

·     Flashing: Data is being received or/and transmitted.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

HMIM-8E1(75)/HMIM-8E1-F(75)

Introduction

The 8-port channelized E1/PRI interface module (HMIM-8E1(75)) transmits, receives, and processes eight channels of E1 data traffic. In addition, you can use the module for other purposes, such as CE1 access and the ISDN PRI function.

The 8-port fractional E1 interface module (HMIM-8E1-F(75)) is different from the HMIM-8E1(75) module in the sense that:

·     The FE1 operating mode supported by the HMIM-8E1-F(75) module allows only one n No 64 Kbps bundle to be formed on each interface, where the value range of n is 1 to 31. However, an HMIM-8E1(75) module allows arbitrary grouping of 31 channels and therefore multiple bundles.

·     The HMIM-8E1-F(75) module does not support PRI mode.

 

 

NOTE:

For an HMIM-8E1(75) module, the system automatically creates a serial interface for each timeslot bundle formed on a controller E1 interface.

 

Interface specifications

Table 162 Interface specifications

Item

Description

Connector type

D68

Number of connectors

1

Interface standard

G.703

Interface rate

2.048 Mbps

Cable type

75-ohm 8E1 conversion cable

Cable characteristic impedance

75 ohm

Operating mode

·     E1, CE1, ISDN PRI (only supported by the HMIM-8E1(75))

·     FE1 (only supported by the HMIM-8E1-F(75))

Supported services

·     Backup

·     Terminal access service

·     ISDN PRI (only supported by the HMIM-8E1(75))

 

Interface LEDs

Figure 123 HMIM-8E1(75) panel

 

Figure 124 HMIM-8E1-F(75) panel

 

Table 163 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

RT-HMIM-2E1-V3/RT-HMIM-4E1-V3/RT-HMIM-8E1-V3

CAUTION

CAUTION:

The RT-HMIM-2E1-V3/RT-HMIM-4E1-V3/RT-HMIM-8E1-V3 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The RT-HMIM-2E1-V3/RT-HMIM-4E1-V3/RT-HMIM-8E1-V3 module stands for 2/4/8-port channelized CE1/PRI and fractional E1 (E1-F) interface module.

The module provides the following features:

·     Channelized CE1/PRI modeThe module allows arbitrary grouping of 31 channels and multiple bundles. It transmits/receives and handles E1 data streams, provides CE1 access, and supports ISDN PRI.

·     Unchannelized E1 modeInterfaces on the module are 2.048 Mbps synchronous serial interfaces without timeslot division.

·     Fractional E1 (E1-F) modeThe time slots can only be bundled into one n x 64 kbps channel, where the value range of n is 1 to 31. The module does not support PRI mode.

Interface specifications

Table 164 Interface specifications

Item

RT-HMIM-2E1-V3

RT-HMIM-4E1-V3

RT-HMIM-8E1-V3

Connector type

RJ-45

RJ-45

RJ-45

Number of connectors

2

4

8

Interface standard

G.703

Interface rate

2.048 Mbps

Cable type

·     E1 120-ohm balanced twisted pair cable: 2 m (6.56 ft), 15 m (49.21 ft), or 30 m (98.43 ft)

·     E1 75-ohm unbalanced coaxial cable

·     75-ohm adapter cable

·     Coaxial connector, network interface connector, and 75-ohm to 120-ohm adapter (with BNC connector)

Operating mode

·     Unchannelized E1 (G.703)

·     Channelized E1 (CE1/PRI)

·     Fractional E1 (E1-F)

Supported services

·     Backup

·     Terminal access service

·     ISDN PRI

 

 

NOTE:

The E1 cable after extension supports a maximum transmission distance of 100 m (328.08 ft).

 

Interface LEDs

Figure 125 RT-HMIM-2E1-V3 panel

 

Figure 126 RT-HMIM-4E1-V3 panel

 

Figure 127 RT-HMIM-8E1-V3 panel

 

On the panel, each port corresponds to one green LED and one yellow LED. Table 165 describes the LEDs on the panel.

Table 165 LED description

LED

Status

Description

LINK/ACT

Steady green

A carrier signal has been received.

Flashing green

Data is being transmitted or/and received.

Off

No carrier signal has been received.

LP/AL

Steady yellow

The interface is in loopback mode.

Flashing yellow

No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

Off

No loopback or alarm is present.

RUN

Steady green

The module is operating correctly. You cannot remove it.

Off

The module is not recognized and you can remove it, or the module has been removed.

 

Jumper caps

The RT-HMIM-2E1-V3/RT-HMIM-4E1-V3/RT-HMIM-8E1-V3 interface module provides jumper caps, the installation status of which determines the interface impedance. By default, each pin pair is installed with a jumper cap and the impedance of an E1 interface is 75 ohms.

To connect a 120-ohm cable to an E1 interface, remove the jumper caps from the pins corresponding to the interface.

Figure 128 Default installation status of jumper caps (RT-HMIM-8E1-V3 as an example)

 

Every two interfaces on the interface module correspond to a jumper connector, and the pin settings are the same for the jumper connectors. You can set different impedance modes for the interfaces. For example, an RT-HMIM-8E1-V3 interface module has four jumper connectors, with each jumper connector corresponding to two interfaces. The pins on a jumper connector are numbered PIN1 through PIN14. To set the impedance to 75 ohms for E1 interface 0, install jumper caps on pins 1 and 2, pins 3 and 4, and pins 5 and 6. To connect a 120-ohm cable to the E1 interface, remove the jumper caps from these pins. Table 166 displays the mapping relations between pins on jumper connectors and E1 interfaces.

Table 166 Mapping relations between pins on jumper connectors and E1 interfaces

Jumper connector

Pins

E1 interface

Supported interface modules

1

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 0

RT-HMIM-2E1-V3

RT-HMIM-4E1-V3

RT-HMIM-8E1-V3

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 1

Pins 13 and 14

Keep the jumper cap in its default installation status

2

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 2

RT-HMIM-4E1-V3

RT-HMIM-8E1-V3

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 3

Pins 13 and 14

Keep the jumper cap in its default installation status

3

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 4

RT-HMIM-8E1-V3

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 5

Pins 13 and 14

Keep the jumper cap in its default installation status

4

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 6

RT-HMIM-8E1-V3

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 7

Pins 13 and 14

Keep the jumper cap in its default installation status

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

HMIM-2T1/HMIM-4T1-F

Introduction

The 2-port channelized CT1/PRI interface module (HMIM-2T1) serves to transmit/receive and handle T1 data streams, provide CT1 access, and fulfill the function of ISDN PRI. Thereby, one module can be used for multiple purposes.

The 4-port fractional T1 interface module (HMIM-4T1-F) is different from the HMIM-CT1 module in the sense that:

·     FT1 operating mode supported by T1-F modules allows only one bundle. In other words, the time slots can only be bundled into one n x 64 Kbps/56 Kbps channel, where the value range of n is 1 to 24. However, a CT1 module allows of arbitrary grouping of the 24 channels.

·     T1-F does not support PRI mode.

 

 

NOTE:

For a T1 module, the system automatically creates a serial interface for each timeslot bundle formed on a controller T1 interface.

 

Interface specifications

Table 167 Interface specifications

Item

Description

Connector type

RJ-45

Number of connectors

·     2 (HMIM-2T1)

·     4 (HMIM-4T1-F)

Interface standard

·     G.703/T1 102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

cable type

T1 cable (100-ohm shielding network cable)

Operating mode

CT1, ISDN PRI (only supported by the HMIM-2T1)

FT1 (only supported by the HMIM-4T1-F)

Supported services

·     Backup

·     Terminal access service

·     ISDN PRI (only supported by the HMIM-2T1)

 

Interface LEDs

Figure 129 HMIM-2T1 panel

 

Figure 130 HMIM-4T1-F panel

 

Table 168 LED description

LEDs

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being transmitted or/and received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

HMIM-2E1T1/HMIM-4E1T1/HMIM-8E1T1/HMIM-2E1T1-F/HMIM-4E1T1-F/HMIM-8E1T1-F

Introduction

·     HMIM-2E1T1/HMIM-4E1T1/HMIM-8E1T1 module

The 2/4/8-port channelized E1/CE1/T1/CT1/PRI interface module transmits/receives and handles T1 data streams, provides CT1 access, and supports ISDN PRI. The module allows arbitrary grouping of 31 channels.

·     HMIM-2E1T1-F/HMIM-4E1T1-F/HMIM-8E1T1-F module

The 2/4/8-port fractional T1 interface module allows only one bundle. The time slots can only be bundled into one n x 64 Kbps/56 Kbps channel, where the value range of n is 1 to 31. The module does not support PRI mode.

·     HMIM-2E1T1/HMIM-4E1T1/HMIM-8E1T1(-F) jumper settings

You can use command lines and a jumper to configure an interface on the interface module as a 75-ohm E1 interface, 100-ohm T1 interface, or 120-ohm E1 interface. By default, an interface is a 75-ohm E1 interface.

¡     To configure an interface on the interface module as a 75-ohm E1 interface, connect the jumper to pins 1 and 2, pins 7 and 8, pins 11 and 12, and pins 13 and 14.

¡     To configure an interface on the interface module as a 100-ohm T1 or 120-ohm E1 interface, connect the jumper to pins 1 to 3, pins 5 to 7, pins 9 and 10, and pins 11 to 13.

Figure 131 Jumper connecting methods

 

 

NOTE:

·     An interface corresponds to a jumper connector. Pin settings for the jumper connectors are the same.

·     Each interface comes with four jumper caps.

·     All interfaces must operate in the same mode.

 

Interface specifications

Table 169 Interface specifications

Item

HMIM-2E1T1/
HMIM-2E1T1-F

HMIM-4E1T1/
HMIM-4E1T1-F

HMIM-8E1T1/
HMIM-8E1T1-F

Connector type

RJ-45

RJ-45

RJ-45

Number of connectors

2

4

8

Interface standard

·     G.703/G.704

·     T1 102

·     AT&T TR 54016

·     AT&T TR 62411

·     ANSI T1.403

Interface rate

·     1.544 Mbps

·     2.048 Mbps

Supported cable

·     E1 75-ohm unbalanced twisted pair cable

·     E1 120-ohm balanced twisted pair cable

·     T1 cable (100-ohm shielding network cable)

·     Coaxial connector, network connector, 75-to-120-ohm adapter (with BNC connector)

Operating mode

·     E1/T1/CE1T1/ISDN PRI (only supported by the HMIM-2E1T1/HMIM-4E1T1/HMIM-8E1T1 module)

·     FE1T1 (only supported by the HMIM-2E1T1-F/HMIM-4E1T1-F/HMIM-8E1T1-F module)

Supported services

·     Backup

·     Terminal access service

·     ISDN PRI (only supported by the HMIM-2E1T1/HMIM-4E1T1/HMIM-8E1T1 module)

 

Interface LEDs

Figure 132 HMIM-2E1T1 panel

 

Figure 133 HMIM-2E1T1-F panel

 

Figure 134 HMIM-4E1T1 panel

 

Figure 135 HMIM-4E1T1-F panel

 

Figure 136 HMIM-8E1T1 panel

 

Figure 137 HMIM-8E1T1-F panel

 

Table 170 LED description

LED

Status

Description

LINK/ACT

Steady green

A carrier signal has been received.

Flashing green

Data is being transmitted or/and received.

Off

No carrier signal has been received.

LP/AL

Steady yellow

The interface is in loopback mode.

Flashing yellow

No cable is connected to the interface, the cable is damaged or not connected correctly, or the peer device is faulty.

Off

No loopback or alarm is present.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

For more information about T1 interface cables and the connection methods, see "T1 interface."

E3/T3 interface modules

·     HMIM-1CE3

HMIM-1CE3

Introduction

The 1-port channelized E3 interface module (HMIM-1CE3) serves to:

·     Transmit/receive and handle one channel of E3 fast traffic, as well as provide the accessing of E3 traffic when operating in E3 mode.

·     Provide the low-speed accessing service at the speed of n No 64 kbps, where "n" is smaller than or equal to 128, when operating in CE3 mode.

 

 

NOTE:

E3 represents the tertiary group rate of E system in the TDM system, that is, 34.368 Mbps. An E3 channel can be channelized into 16 E1 lines through the demultiplexing processes of E23 and E12, each E1 line supporting both the operating modes of E1 and CE1. E23 is used to indicate either E2-to-E3 multiplex or E3-to-E2 demultiplex, and E12 to indicate E1-to-E2 multiplex or E2-to-E1 demultiplex. "E23" and "E12" discussed here represent the demultiplex process.

 

Interface specifications

Table 171 Interface specifications

Item

Description

Connector type

SMB

Number of connectors

2

Interface standard

G.703, G.704, and G.751

Interface rate

34.368 Mbps

Cable type

E3 cable (75-ohm coaxial cable)

Operating mode

·     E3

·     CE3

Supported services

E3 leased line

 

Interface LEDs

Figure 138 HMIM-1CE3 panel

 

Table 172 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Flashing: Data is being received or/and transmitted.

·     Off: No carrier signal is received.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Interface cables and the connection methods

For more information about E3 interface cables and the connection methods, see "E3/T3 interface."

Serial interface modules

·     HMIM-2SAE

·     HMIM-4SAE

·     HMIM-8SAE

·     RT-HMIM-4SAE-V2

·     RT-HMIM-8SAE-V2

·     HMIM-8ASE

·     HMIM-16ASE

·     RT-HMIM-8ASE-V2

·     RT-HMIM-16ASE-V2

HMIM-2SAE/HMIM-4SAE/HMIM-8SAE

Introduction

The 2-port SAE module (HMIM-2SAE), 4-port SAE module (HMIM-4SAE), and 8-port SAE module (HMIM-8SAE) are enhanced high-speed synchronous/asynchronous serial interface modules. In terms of function, SAE modules are the same as SA modules except that SAE modules support more protocols, for example, RS449, X.21, and RS530.

Interface specifications

Table 173 Interface specifications

Item

Synchronous

Asynchronous

Connector type

D28

Number of connectors

2 (HMIM-2SAE)

4 (HMIM-4SAE)

8 (HMIM-8SAE)

Interface standard and operating mode

V.24

V.35, RS449, X.21, and RS530

RS-232

DTE and DCE

DTE and DCE

Minimum baud rate (bps)

1200

1200

300

Maximum baud rate (bps)

64000

2048000

115200

cable type

V.24 DTE cable

V.24 DCE cable

V.35 DTE cable

V.35 DCE cable

X.21 DTE cable

X.21 DCE cable

RS449 DTE cable

RS449 DCE cable

RS530 DTE cable

RS530 DCE cable

Supported services

·     DDN leased line

·     Terminal access service

·     Dialup through modems

·     Backup

·     Asynchronous leased line

·     Dumb terminal access

 

Interface LEDs

Figure 139 HMIM-2SAE panel

 

Figure 140 HMIM-4SAE panel

 

Table 174 LED description

LED

Description

LINK

·     Off: No link is present.

·     On: A link is present.

ACT

·     Off: No data is being transmitted or received.

·     Flashing: Data is being received or/and transmitted.

 

Figure 141 HMIM-8SAE panel

 

On the HMIM-8SAE module, each link corresponds to a LED. The LED state indicates the link state as follows:

·     OnA link is present.

·     Flashing—Data is being transmitted or received.

·     Off—No data is being transmitted or received.

Interface cables and the connection methods

For more information about synchronous/asynchronous serial port cables and the connection methods, see "Synchronous/asynchronous serial ports."

RT-HMIM-4SAE-V2/RT-HMIM-8SAE-V2

CAUTION

CAUTION:

The RT-HMIM-4SAE-V2/RT-HMIM-8SAE-V2 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The 4-port SAE module (RT-HMIM-4SAE-V2) and 8-port SAE module (RT-HMIM-8SAE-V2) are enhanced high-speed synchronous/asynchronous serial interface modules. In terms of function, SAE modules are the same as SA modules except that SAE modules support more protocols, for example, RS449, X.21, and RS530.

Interface specifications

Table 175 Interface specifications

Item

Synchronous

Asynchronous

Connector type

D28

Number of connectors

4 (RT-HMIM-4SAE-V2)

8 (RT-HMIM-8SAE-V2)

Interface standard and operating mode

V.24

V.35, RS449, X.21, and RS530

RS-232

DTE and DCE

DTE and DCE

Minimum baud rate (bps)

1200

1200

300

Maximum baud rate (bps)

64000

2048000

115200

Cable type

V.24 DTE cable

V.24 DCE cable

V.35 DTE cable

V.35 DCE cable

X.21 DTE cable

X.21 DCE cable

RS449 DTE cable

RS449 DCE cable

RS530 DTE cable

RS530 DCE cable

Supported services

·     DDN leased line

·     Terminal access service

·     Backup

·     Asynchronous leased line

·     Terminal access

 

Interface LEDs

Figure 142 RT-HMIM-4SAE-V2 panel

 

Figure 143 RT-HMIM-8SAE-V2 panel

 

Table 176 LED description

LED

Status

Description

RUN

Steady green

The module is operating correctly. You cannot remove it.

Off

The module is not recognized and you can remove it, or the module has been removed.

LINK/ACT

Steady green

A link is present.

Flashing green

Data is being received or/and transmitted.

Off

No link is present.

 

Interface cables and the connection methods

For more information about synchronous/asynchronous serial port cables and the connection methods, see "Synchronous/asynchronous serial ports."

HMIM-8ASE/HMIM-16ASE

Introduction

The 8-port ASE module (HMIM-8ASE) and the 16-port ASE module (HMIM-16ASE) are enhanced asynchronous serial interface modules that are used to transmit, receive, and handle asynchronous serial interface data streams. ASE modules use RJ-45 connectors and AUX cables.

Interface specifications

Table 177 Interface specifications

Item

HMIM-8ASE

HMIM-16ASE

Connector type

RJ-45

Number of connectors

8 (HMIM-8ASE)

16 (HMIM-16ASE)

Interface standard and operating mode

RS-232

cable type

·     AUX cable

·     Standard (straight-through) Ethernet cable

·     HMIM-8ASE/HMIM-16ASE dumb terminal cable

Minimum baud rate (bps)

300

Maximum baud rate (bps)

115.2 k

Supported services

·     Dialup through a modem

·     Backup

·     Terminal access service

·     Asynchronous leased line service

 

Interface LEDs

Figure 144 HMIM-8ASE panel

 

Figure 145 HMIM-16ASE panel

 

Each channel on HMIM-8ASE/HMIM-16ASE has only one LED. The LED state indicates the link state as follows:

·     On—A link is present.

·     Flashing—Data is being transmitted or received.

·     Off—No link is present.

Interface cables and the connection methods

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

RT-HMIM-8ASE-V2/RT-HMIM-16ASE-V2

CAUTION

CAUTION:

The RT-HMIM-8ASE-V2/RT-HMIM-16ASE-V2 module is hot swappable. To remove it, first press and hold the remove button until the RUN LED is off.

 

Introduction

The 8-port ASE module (RT-HMIM-8ASE-V2) and the 16-port ASE module (RT-HMIM-16ASE-V2) are enhanced asynchronous serial interface modules that are used to transmit, receive, and handle asynchronous serial interface data streams. ASE modules use RJ-45 connectors and AUX cables.

Interface specifications

Table 178 Interface specifications

Item

RT-HMIM-8ASE-V2

RT-HMIM-16ASE-V2

Connector type

RJ-45

Number of connectors

·     8 (RT-HMIM-8ASE-V2)

·     16 (RT-HMIM-16ASE-V2)

Interface standard and operating mode

RS-232

cable type

·     AUX cable

·     Standard (straight-through) Ethernet cable

·     Dumb terminal cable

Minimum baud rate (bps)

300

Maximum baud rate (bps)

115.2 k

Supported services

·     Dialup through a modem

·     Backup

·     Terminal access service

·     Asynchronous leased line service

 

Interface LEDs

Figure 146 RT-HMIM-8ASE-V2 panel

 

Figure 147 RT-HMIM-16ASE-V2 panel

 

Each channel on RT-HMIM-8ASE-V2/RT-HMIM-16ASE-V2 has only one LED. The LED state indicates the link state as follows:

·     On—A link is present.

·     Flashing—Data is being transmitted or received.

·     Off—No link is present.

Interface cables and the connection methods

For more information about asynchronous serial port cables and the connection methods, see "Asynchronous serial ports."

POS terminal access interface modules

·     HMIM-1E1POS

·     DHMIM-1E1POS1DM

HMIM-1E1POS

Introduction

The HMIM-1E1POS is a 1-port channelized E1 high-density POS access interface module. Each E1 port can deal with incoming calls from 30 POS terminals at the same time. The HMIM-1E1POS is applicable to the bank data transaction center for smart card accounting management.

 

 

NOTE:

The POS access service is a type of smart card service widely used in places such as shopping malls and gasoline service stations. It links a POS terminal device located in a shopping mall or a gasoline service station to a bank card accounting system to provide services.

 

 

NOTE:

·     The HMIM-1E1POS uses the PRI voice protocol, but cannot be used for regular voice calling. The voice subscriber lines that the HMIM-1E1POS generates cannot be used as regular voice interfaces, and cannot be bound to the voice entities.

·     The PRI interface is used for transmitting service data. The interfaces Diag Port0 and Diag Port1 are used only for device debugging.

 

Interface specifications

Table 179 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

1

Cable

120-ohm standard non-shield cable

Operating mode

PRI

Supported protocols

Synchronous mode:

·     ITU-T-V.22 (PSK/QPSK)

·     V.22 BIS (QAM)

Supported services

POS call in PRI mode

 

Interface LEDs

Figure 148 HMIM-1E1POS panel

 

Table 180 LED description

LED

Description

LINK/ACT

·     Steady green: A carrier signal is detected.

·     Flashing green: Data is being received or transmitted.

·     Off: No carrier signals are detected.

LP/AL

·     Steady yellow: The interface is in loopback.

·     Flashing yellow: An alarm is present.

·     Off: No loopback or alarm is present.

 

Interface cable

The HMIM-1E1POS uses the 120-ohm unshielded E1 cable with RJ-45 connecters at both ends.

Figure 149 HMIM-1E1POS interface cable

标准网线

 

 

NOTE:

The HMIM-1E1POS does not come with the interface cable. You need to order for the E1 cable.

 

Connecting the interface cable

CAUTION

CAUTION:

·     Before connecting a port, read its label carefully. A wrong connection can cause damages to the interface module and even the device.

·     As a best practice, add a lightning arrester between an interface cable and interface module for better lightning protection when the cable is routed outdoors.

 

To connect the interface cable:

1.     Connect one end of the interface cable to the RJ-45 port on the HMIM-1E1POS.

2.     Connect the other end of the interface cable to the peer device.

3.     Examine the status of the LINK LED on the HMIM-1E1POS. If the LINK LED is off, examine the cable connection and cable condition.

DHMIM-1E1POS1DM

Introduction

The DHMIM-1E1POS1DM is a 1-port channelized E1 high-density POS access interface module. Each E1 port can deal with incoming calls from 30 POS terminals at the same time. The DHMIM-1E1POS1DM is applicable to the bank data transaction center for smart card accounting management.

The DHMIM-1E1POS1DM can operate as the HMIM-1E1POS or the DHMIM-1DM. When the E1 port of the DHMIM-1E1POS1DM operates in asynchronous mode, you can upgrade the POS device remotely.

 

 

NOTE:

The PRI interface is used for transmitting service data. The interfaces Diag Port0 and Diag Port1 are used only for device debugging.

 

Interface specifications

Table 181 Interface specifications

Item

Description

 

Connector

RJ-45

 

Number of connectors

1

 

Cable

120-ohm standard non-shielded cable

 

Operation mode

PRI

Supported protocols

·     Synchronous mode:

¡     ITU-T-V.22 (PSK/QPSK)

¡     V.22 BIS (QAM)

·     Asynchronous mode:

¡     ITU-T V.92

¡     V.90

¡     V.34

¡     V.32 bis

¡     V.32

¡     V.23

¡     V.22 bis

¡     V.22

¡     V.21

¡     Bell 212a

¡     Bell 103

Supported services

POS call in PRI mode

 

 

Interface LEDS

Figure 150 DHMIM-1E1POS1DM panel

 

Table 182 LED description

LED

Description

LINK/ACT

·     Steady green: The carrier signal is detected.

·     Flashing green (8 Hz): Data is being received or transmitted.

·     Off: No carrier signals are detected.

LP/AL

·     Steady yellow: The interface is in loopback.

·     Flashing yellow (1 Hz): An alarm is present.

·     Off: No loopback or alarm is present.

 

Connecting the interface cable

CAUTION

CAUTION:

·     As a best practice, add a lightning arrester between an interface cable and interface module for better lightning protection when the cable is routed outdoors.

·     Before connecting a port, read its label carefully. A wrong connection might cause damages to the interface module and even the device.

 

If the interface module has been properly installed, follow these steps to connect the cable:

1.     Connect one end of the interface cable to the RJ-45 port on the DHMIM-1E1POS1DM.

2.     Connect the other end of the interface cable to the peer device.

3.     Examine the status of the LINK LED on the DHMIM-1E1POS1DM. If the LINK LED is off, examine the cable connection and cable condition.

Digital modem interface modules

·     DHMIM-1DM

DHMIM-1DM

Introduction

The DHMIM-1DM is a 1-port channelized E1 high-density digital modem interface module. You can upgrade the POS device remotely.

 

 

NOTE:

The PRI interface is used for transmitting service data. The interfaces Diag Port0 and Diag Port1 are used only for device debugging.

 

Interface specifications

Table 183 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

1

Cable

120-ohm standard non-shielded cable

Operation mode

PRI

Supported protocols

Asynchronous mode:

·     ITU-T V.92

·     V.90

·     V.34

·     V.32 bis

·     V.32

·     V.23

·     V.22 bis

·     V.22

·     V.21

·     Bell 212a

·     Bell 103

Supported services

POS call in PRI mode

 

Interface LEDs

Figure 151 DHMIM-1DM panel

 

Table 184 LED description

LED

Description

LINK/ACT

·     Steady green: The carrier signal is detected.

·     Flashing green (8 Hz): Data is being received or transmitted.

·     Off: No carrier signals are detected.

LP/AL

·     Steady yellow: The interface is in loopback.

·     Flashing yellow (1 Hz): An alarm is present.

·     Off: No loopback or alarm is present.

 

Connecting the interface cable

CAUTION

CAUTION:

·     As a best practice, add a lightning arrester between an interface cable and interface module for better lightning protection when the cable is routed outdoors.

·     Before connecting a port, read its label carefully. A wrong connection might cause damages to the interface module and even the device.

 

If the interface module has been properly installed, follow these steps to connect the cable:

1.     Connect one end of the interface cable to the RJ-45 port on the DHMIM-1DM.

2.     Connect the other end of the interface cable to the peer device.

3.     Examine the status of the LINK LED on the DHMIM-1DM. If the LINK LED is off, examine the cable connection and cable condition.

Voice interface modules

·     HMIM-16FXS

·     HMIM-8FXS8FXO

·     HMIM-2VE1

·     HMIM-2VT1

·     HMIM-1VE1

·     HMIM-1VT1

·     HMIM-4FXS

·     HMIM-4FXO

·     HMIM-4E&M

HMIM-16FXS

Introduction

The 16-port loop trunk interface module (HMIM-16FXS) serves to access and handle 16 channels of analog voice signals over data communication networks. The module provides 16 FXS interfaces.

FXS interfaces are analog subscriber line interfaces that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges.

Interface specifications

Table 185 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

16 (FXS interfaces)

Interface standard

·     ITU Q.512-compliant subscriber circuit interface (FXS)

·     ITU K.20-compliant over-current and over-voltage protection

Cable type

Telephone cable with ferrite core

Dial-up mode

DTMF, compliant with GB3378 (Pulse dial-up is not available.)

Bandwidth

300 to 3400 Hz

Ringing voltage

40 V

 

Interface LEDs

Figure 152 HMIM-16FXS front panel

 

Table 186 LED description

LED

Description

LINK/ACT

·     Steady green: A link is present and a call connection is being established.

·     Off: No link is present.

·     Flashing yellow: A link is present and there is a call activity.

 

Interface cables and the connection methods

For more information about FXS interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

HMIM-8FXS8FXO

Introduction

The 8-port analog subscriber circuit interface module and 8-port voice AT0 loop trunk interface module (HMIM-8FXS8FXO) serve to access and handle 16 channels of analog voice signals over data communication networks. Eight FXS interfaces and eight FXO interfaces are available on an HMIM-8FXS8FXO module:

·     FXS interfaces are analog subscriber line interfaces that provide ordinary analog telephone and fax access and also can connect AT0 loop trunks of exchanges;

·     FXO interfaces are loop trunk interfaces that provide access of common subscriber lines of exchanges.

When you use the HMIM-8FXS8FXO module in a device, make sure the device has been connected to the IP network or other WAN.

Interface specifications

Table 187 Interface specifications

Item

Description

Connector type

RJ-11

Number of connectors

·     8 FXS interfaces

·     8 FXO interfaces

Interface standard

·     ITU Q.512-compliant subscriber circuit interface (FXS)

·     ITU Q.552-compliant loop trunk interface (FXO)

·     ITU K.20-compliant over-current and over-voltage protection

Cable type

Telephone cable with ferrite core

Dial-up mode

DTMF, compliant with GB3378 (Pulse dial-up is not available.)

Bandwidth

300 Hz to 3400 Hz

Ringing voltage

40 V

 

Interface LEDs

Figure 153 HMIM-8FXS8FXO front panel

 

Table 188 LED description

LED

Description

LINK/ACT

·     Steady green: The link is being occupied for a call connection.

·     Off: The link is idle.

·     Flashing yellow: The link is being occupied for communication.

 

Interface cables and the connection methods

For more information about FXS interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

HMIM-2VE1

Introduction

The 2-port E1 voice interface module (HMIM-2VE1) can handle dense voice signals in VoIP system. It provides two CE1/PRI/R2 ports, allowing the access of 60 channels of voice signals.

Interface specifications

Table 189 Interface specifications

Item

Description

Connector

D15

Number of connectors

2

Operating mode

·     CE1

·     ISDN PRI

·     R2

Interface rate

2.048 Mbps

Cable type

·     E1 75-ohm unbalanced coaxial cable

·     E1 120-ohm balanced twisted pair cable

·     Coaxial connector, network interface connector, and 75-to-120-ohm adapter (with BNC connector)

Supported service

·     R2 signaling

·     DSS1 signaling

·     IP Fax

·     General VoIP features in Comware

 

Interface LEDs

Figure 154 HMIM-2VE1 panel

 

Table 190 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being received and/or transmitted.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

HMIM-2VT1

Introduction

The 2-port T1 voice interface module (HMIM-2VT1) can handle dense voice signals in VoIP system. It provides two CT1/PRI ports, allowing the access of 48 channels of voice signals.

Interface specifications

Table 191 Interface specifications

Item

Description

Connector

RJ-45

Number of connector

2

Interface standard

·     G.703/T1.102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm standard shielded cable)

Operation mode

·     CT1

·     ISDN PRI

Services

·     Backup

·     Terminal access

·     ISDN

 

Interface LEDs

Figure 155 HMIM-2VT1 panel

 

Table 192 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being received and/or transmitted.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

HMIM-1VE1

Introduction

The 1-port E1 voice interface module (HMIM-1VE1) can handle dense voice signals in VoIP system. It provides a CE1/PRI/R2 port, allowing the access of 30 channels of voice signals.

Interface specifications

Table 193 Interface specifications

Item

Description

Connector

D15

Number of connectors

1

Operating mode

·     CE1

·     ISDN PRI

·     R2

Interface rate

2.048 Mbps

Cable

·     E1 75-ohm unbalanced coaxial cable

·     E1 120-ohm balanced twisted pair cable

·     Coaxial connector, network interface connector, and 75ohm-to-120ohm adapter (with BNC connector)

Supported service

·     R2 signaling

·     DSS1 signaling

·     IP Fax

·     General VoIP features in Comware

 

Interface LEDs

Figure 156 HMIM-1VE1 panel

 

Table 194 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being received and/or transmitted.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface."

HMIM-1VT1

Introduction

The 1-port T1 voice interface module (HMIM-1VT1) can handle dense voice signals in VoIP system. It provides a CT1/PRI port, allowing the access of 24 channels of voice signals.

Interface specifications

Table 195 Interface specifications

Item

Description

Connector

RJ-45

Number of connector

1

Interface standard

·     G.703/T1.102

·     G.704

·     AT & T TR 54016

·     AT & T TR 62411

·     ANSI T1.403

Interface rate

1.544 Mbps

Cable type

T1 cable (100-ohm standard shielded cable)

Operation mode

·     CT1

·     ISDN PRI

Services

·     Backup

·     Terminal access

·     ISDN

 

Interface LEDs

Figure 157 HMIM-1VT1 panel

 

Table 196 LED description

LED

Description

LINK/ACT

·     On: A carrier signal is received.

·     Off: No carrier signal is received.

·     Flashing: Data is being received and/or transmitted.

LP/AL

·     On: The interface is in loopback mode.

·     Off: No loopback or alarm is present.

·     Flashing: An alarm indication signal (AIS), loss of frame alignment (LFA) signal, or remote alarm indication (RAI) signal is present.

 

Interface cables and the connection methods

For more information about T1 interface cables and the connection methods, see "T1 interface."

HMIM-4FXS/HMIM-4FXO

Introduction

The 4-port voice subscriber circuit interface module (HMIM-4FXS) processes and transmits over data communications networks voice signals for 2/4 regular analog phones, faxes, or AT0 loop trunks of telephone exchanges.

The 4-port voice AT0 analog trunk interface module (HMIM-4FXO) processes and transmits over data communications networks voice signals for 2/4 loops of telephone exchanges.

Interface specifications

Table 197 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

4

Cable

·     Telephone cable with ferrite core

·     E&M trunk cable (only for E&M modules, made on site)

Interface standard

·     ITU Q.512-compliant subscriber circuit interface (HMIM-4FXS)

·     ITU Q.552-compliant loop trunk interface (HMIM-4FXO)

·     ITU K.20-compliant over-current and over-voltage protection

Dial-up mode

DTMF, compliant with GB3378 (Pulse dial-up is not available.)

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 158 HMIM-4FXS panel

 

Figure 159 HMIM-4FXO panel

 

Table 198 LED description

LED

Description

LINK

·     On: A link is present.

·     Off: No link is present.

ACT

·     On: There is call activity.

·     Off: The channel is idle.

 

Interface cables and the connection methods

For more information about FXS/FXO interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

HMIM-4E&M/HMIM-8E&M

Introduction

The 4/8-port voice E&M analog trunk interface module (HMIM-4E&M/HMIM-8E&M) provides and transmits over data communications networks voice signals for 4/8 E&M analog trunks.

Interface specifications

Table 199 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

·     4 (HMIM-4E&M)

·     8 (HMIM-8E&M)

Cable type

·     Telephone cable with ferrite core

·     E&M trunk cable (only for E&M modules, made on site)

Interface standard

·     G.712-compliant E&M trunk interface (HMIM-4E&M/HMIM-8E&M), E&M interface (supporting Bell type I, II, III, V, and support 2-wire and 4-wire)

·     ITU K.20-compliant over-current and over-voltage protection

Dial-up mode

DTMF, compliant with GB3378 (Pulse dial-up is not available.)

Bandwidth

300 Hz to 3400 Hz

 

Interface LEDs

Figure 160 HMIM-4E&M panel

 

Figure 161 HMIM-8E&M panel

 

Table 200 LED description

LED

Status

Description

LINK

Steady green

A link is present.

Off

No link is present.

ACT

Steady yellow

There is call activity..

Off

The channel is idle.

 

Interface cables and the connection methods

For more information about E&M interface cables and the connection methods, see "E&M interface."

Analog modem modules

·     HMIM-6AM

·     HMIM-6FCM

HMIM-6AM

Introduction

The 6-port analog modem interface module (HMIM-6AM) provides six channels of user dial-in and dial-out, and provides a connection speed of 56 kbps when ITU-T V.90 is applied. Working with the MSR routers, it provides medium-density RAS functions.

Interface specifications

Table 201 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

6

Cable

Telephone cable

Interface rate

56 kbps

Interface standard

ITU-T V.90, K56flex, V.34 (33.6 kbps), V.FC, V.32 bis, V.32, V.22 bis, V.22A/B, V.23, V.21, Bell 212A a, and Bell 103

Supported service

Dialup through modem

 

Interface LEDs

Figure 162 HMIM-6AM panel

 

Table 202 LED description

LED

Description

LINK

·     On: A link is present.

·     Off: No link is present.

·     Flashing: A link is being established.

ACT

·     Off: No data is being transmitted or received.

·     Flashing: Data is being transmitted and/or received.

 

Interface cables and the connection methods

For more information about AM interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

HMIM-6FCM

Introduction

The 6-port fast connect modem interface module (HMIM-6FCM) provides POS terminal devices to fast dial up to a bank card accounting system.

 

 

NOTE:

The POS access service refers to a type of smart card service widely used in places such as shopping malls and gasoline service stations. It links a POS terminal device located in a shopping mall or a gasoline service station to a bank card accounting system to provide services.

 

Interface specifications

Table 203 Interface specifications

Item

Description

Connector

RJ-45

Number of connectors

6

Cable

Telephone cable with ferrite core

Supported protocols

ITU-T V.22

 

Interface LEDs

Figure 163 HMIM-6FCM panel

 

Table 204 LED description

LED

Description

CD

·     Off: No carrier signals are detected.

·     On: A carrier signal is detected.

ACT

·     Flashing: Data is being received or transmitted.

·     Off: No data is being received or transmitted.

 

Interface cables and the connection methods

For more information about FCM interface cables and the connection methods, see "ADSL/BS/FXS/FXO/AM/FCM interface."

Network data encryption modules

HMIM-CNDE-SJK

Introduction

The HMIM-CNDE-SJK (CNDE is the acronym of China Network Data Encryption) supports SM1, SM2, and SM4 encryption algorithms and provides high performance and reliable data encryption features for routers.

Interface LEDs

Figure 164 HMIM-CNDE-SJK panel

 

Table 205 LED description

LED

Description

RUN

·     Steady green: The module is operating correctly and is not sending or receiving data.

·     Flashing green: The module is operating correctly and is sending or receiving data.

·     Steady yellow: The module is faulty.

·     Off: The module is not installed securely, or no power is present.

 

HMIM adapters

·     HMIM-Adapter

·     HMIM-Adapter-H

HMIM-Adapter/HMIM-Adapter-H

Introduction

The HMIM-Adapter/HMIM-Adapter-H is designed for MIM-to-HMIM conversions. Some MIMs can operate as HMIMs with an HMIM-Adapter/HMIM-Adapter-H adapter installed. For the MIM-to-HMIM conversion relations, see "Appendix B  Purchase guide."

Views

Figure 165 HMIM-Adapter view

 

Figure 166 HMIM-Adapter-H view

 


VPM modules

VPM purchase guide

·     The HMIM-1VE1/HMIM-1VT1 module provides a voice processing module (VPM) slot. The HMIM-2VE1/HMIM-2VT1 module provides two VPM slots. Each VPM slot is installed with a VPM when the HMIM-1VE1/HMIM-1VT1 module or HMIM-2VE1/HMIM-2VT1 module is shipped from the factory.

·     The main board of the MSR 36-20 router provides a VPM slot. The main boards of the MSR 36-40, MSR 36-60, MSR 56-60, and MSR 56-80 routers provide two VPM slots. The routers do not provide VPMs when shipped from the factory. The number and specifications of VPMs needed depend on the number of calls.

·     The SIC-1VE1/SIC-1VT1 module does not provide any VPM slot, and can only use the VPMs installed on the main board of MSR.

·     The MIM-1VE1/MIM-1VT1 module provides a VPM slot, and the MIM-2VE1/MIM-2VT1 module provides two VPM slots. No VPM is installed when the MIM-1VE1/MIM-1VT1 or MIM-2VE1/MIM-2VT1 module is shipped from the factory.

·     The MIM-1VE1/MIM-1VT1 module must be used with VPM installed. The number of VPMs needed depends on the number of calls.

·     Because the initiator of a three-party conference is responsible for audio mixing, so when using MSR as the initiator of a three-party conference, the main board of MSR must have VPM installed.

Introduction

The voice processing module (VPM) functions encoding/decoding, echo cancellation (EC) and comfortable noise generation (CNG) of voices.

Interface specifications

Table 206 Interface specifications

Item

Description

Number of calls supported

·     8

·     16

·     24

·     32

·     128

·     256

·     512

 

XMIM interface modules

CAUTION

CAUTION:

·     XMIM interface modules can be hot-swapped, with the exception of those with a remove button. To remove an XMIM SIC interface module with a remove button while the device is operating, first press and hold the remove button until the RUN LED is off.

·     For the hot swapping of XMIM interface module, do not install an XMIM interface module during an active/standby MSU switchover. To view the status of dual MSUs, execute the display system stable state command in any view. To remove an XMIM while the device is operating, verify that the RUN LED on the module is steady green.

 

Ethernet interface modules

·     RT-XMIM-8GEE-R

·     RT-XMIM-8GEF-R

·     RT-XMIM-4XP

RT-XMIM-8GEE-R

Description

The RT-XMIM-8GEE-R is an 8-port GE copper port interface module. It is mainly used for communication between the router and LAN.

The RT-XMIM-8GEE-R has the following features:

·     Provides a transmission distance of up to 100 m (328.08 ft) when used with category-5 twisted-pair cables.

·     The interfaces can operate at a data rate of 10 Mbps, 100 Mbps, or 1000 Mbps and support data rate auto-sensing.

·     Supports half-/full-duplex auto-negotiation.

Interface specifications

The following table describes the interface specifications of the RT-XMIM-8GEE-R interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 207 Interface specifications

Item

Description

Connector type

RJ-45

Number of connectors

8

Interface type

MDI/MDIX

Interface standard

802.3/802.3u/802.3ab

Cable

Straight-through and crossover Ethernet cable

Operating mode

10/100/1000 Mbps autosensing

Half/full-duplex auto-negotiation

 

Front panel and LEDs

The RT-XMIM-8GEE-R front panel is as shown in the following figure.

Figure 167 RT-XMIM-8GEE-R front panel

 

The following table describes the LEDs on the RT-XMIM-8GEE-R front panel.

Table 208 LED description

LED

Status

Description

LINK/ACT

Green LED: On

A link is present on the interface and the interface is operating in 1000 Mbps mode

Green LED: Flashing

The interface is transmitting or receiving data, and is operating in 1000 Mbps mode.

Yellow LED: On

A link is present on the interface and the interface is operating in 10 or 100 Mbps mode.

Yellow LED: Flashing

The interface is transmitting or receiving data, and is operating in 10 or 100 Mbps mode.

Off

No link is present on the port.

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified.

Flashing green (1 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Steady yellow

The interface module has failed to complete initialization.

Off

The interface module has not been identified or has been removed.

 

Interface cables and connection methods

For information about the Ethernet interface cables and connection methods, see "Ethernet interface."

RT-XMIM-8GEF-R

Description

The RT-XMIM-8GEF-R is an 8-port GE fiber port interface module. It is mainly used for communication between the router and LAN.

The RT-XMIM-8GEF-R has the following features:

·     Supports multiple types of transceiver modules, providing the flexibility for users to select the transceiver modules that meet their specific needs.

·     The interfaces can operate at a data rate of 100 Mbps or 1000 Mbps and support data rate auto-sensing.

·     Supports half-/full-duplex auto-negotiation

Interface specifications

The following table describes the interface specifications of the RT-XMIM-8GEF-R interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 209 Interface specifications

Item

Description

Interface quantity

8

Connector type

SFP/LC

Interface standard

802.3/802.3u/802.3ab

Operating mode

100/1000 Mbps auto-sensing

Half/full-duplex auto-negotiation

 

Front panel and LEDs

The RT-XMIM-8GEF-R front panel is as shown in the following figure.

Figure 168 RT-XMIM-8GEF-R front panel

 

The interface module provides a LED at the bottom of the front panel for each LED.

Table 210 RT-XMIM-8GEF-R LED description

LED

Status

Description

LINK/ACT

Steady green

A link is present on the interface and the interface is operating in 1000 Mbps mode.

Flashing green

The interface is transmitting or receiving data, and is operating in 1000 Mbps mode.

Steady yellow

A link is present on the interface and the interface is operating in 100 Mbps mode.

Flashing yellow

The interface is transmitting or receiving data, and is operating in 100 Mbps mode.

Off

No link is present on the interface.

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified.

Flashing green (8 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Steady yellow

The interface module has failed to complete initialization.

Off

The interface module has not been identified or has been removed.

 

Transceiver modules, optical fibers, and connection methods

For more information about the transceiver modules, optical fibers, and connection methods, see "Fiber port."

RT-XMIM-4XP

Description

The RT-XMIM-4XP is a 10GBASE-R Ethernet interface module that provides four SFP+ ports. Each port is a Layer 3 service port. The interface module supports port type switching between standard Ethernet and FlexE. The FlexE mode allows flexible bandwidth assignment to meet different service requirements.

Interface specifications

The following table describes the interface specifications of the RT-XMIM-4XP interface module. For information about link mode of the interfaces, see "Link mode of interfaces on Ethernet switching modules and interface modules."

Table 211 Interface specifications

Item

Description

Interface quantity

4

Connector type

SFP+/LC

Interface standard

10GBASE-R

Operating mode

1000 Mbps/10 Gbps auto-sensing, full duplex

 

Front panel and LEDs

The RT-XMIM-4XP front panel is as shown in the following figure.

Figure 169 RT-XMIM-4XP front panel

 

Table 212 RT-XMIM-4XP LED description

LED

Status

Description

LINK/ACT

Steady green

A link is present on the interface and the interface is operating in 10 Gbps mode.

Flashing green

The interface is transmitting or receiving data, and is operating in 10 Gbps mode.

Steady yellow

A link is present on the interface and the interface is operating in 1000 Mbps mode.

Flashing yellow

The interface is transmitting or receiving data, and is operating in 1000 Mbps mode.

Off

No link is present on the interface.

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified.

Flashing green (8 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Steady yellow

The interface module has failed to complete initialization.

Off

The interface module has not been identified or has been removed.

 

Transceiver modules, optical fibers, and connection methods

For more information about the transceiver modules, optical fibers, and connection methods, see "Fiber port."

POS (SDH/SONET) interface modules

·     RT-XMIM-1POS

·     RT-XMIM-2POS

RT-XMIM-1POS/RT-XMIM-2POS

Introduction

The RT-XMIM-1POS/RT-XMIM-2POS is a 1/2-port packet over SDH/SONET (POS) XMIM interface module. The transmission rates of the modules are STM-1/OC-3 (155.52 Mbit/s) and STM-4/OC-12 (622.08 Mbit/s).

The RT-XMIM-1POS/RT-XMIM-2POS module supports PPP, frame relay, and HDLC at the data link layer and IP at the network layer. Interfaces on the RT-XMIM-1POS/RT-XMIM-2POS implements direct packet transmission over SONET/SDH.

Follow these restrictions and guidelines when using the RT-XMIM-1POS/RT-XMIM-2POS interface module:

·     You can use the line-card-mode command to set the POS interfaces on the interface module to operate in STM-1/OC-3 POS mode or STM-4/OC-12 POS mode.

·     The setting of the POS interface-operating mode is applicable to the entire interface module, rather than being specific to an individual interface.

Interface specifications

The following table describes the interface specifications of the RT-XMIM-1POS/RT-XMIM-2POS interface module.

Table 213 RT-XMIM-1POS, RT-XMIM-2POS, and RT-XMIM-4POS interface specifications

Item

Description

RT-XMIM-1POS

RT-XMIM-2POS

Interface standard

·     SONET OC-3/SDH STM-1

·     SONET OC-12/SDH STM-4

Interface quantity

1

2

Connector type

SFP/LC

Interface speed

155.52 Mbps,  622.08 Mbps

 

CAUTION

CAUTION:

When the RT-XMIM-2POS interface module is configured to operate in STM-4/OC-12 POS mode, only the interface marked 0 on the front panel is available, while the other interfaces are not available.

 

Front panel and LEDs

The T-XMIM-1POS and RT-XMIM-2POS front panels are as shown in the following figure.

Figure 170 RT-XMIM-1POS front panel

 

Figure 171 RT-XMIM-2POS front panel

 

The following table describes the LEDs on the front panel.

Table 214 RT-XMIM-1POS/RT-XMIM-2POS LED description

LED

Status

Description

ACT/ALM

Steady green

A link is present on the port.

Flashing green

The interface is receiving or sending data.

Steady yellow

A transceiver module has been installed in the interface, while an alarm is present on the interface.

Off

No transceiver module has been installed in the interface.

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified, or the firmware is being updated.

Flashing green (1 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Steady yellow

The interface module has failed to complete initialization.

Off

The interface module has not been identified or has been removed.

 

Transceiver modules, optical fibers, and connection methods

For more information about the transceiver modules, optical fibers, and connection methods, see "Fiber port."

CPOS (SDH/SONET) interface modules

RT-XMIM-1CPOS

Introduction

The RT-XMIM-1CPOS is a 1-port channelized SDH/SONET interface module. C stands for channelized, and POS for Packet over SDH/SONET. The RT-XMIM-1CPOS provides an interface transmission rate of 155.52 Mbps (STM-1/OC-3).

Interface specifications

The following table describes the interface specifications of the RT-XMIM-1CPOS interface module.

Table 215 RT-XMIM-1CPOS interface specifications

Item

Description

Interface standard

SONET OC-3/SDH STM-1

Interface quantity

1

Connector type

SFP/LC

Interface speed

155.52 Mbps

 

Front panel and LEDs

The RT-XMIM-1CPOS front panel is as shown in the following figure.

Figure 172 RT-XMIM-1CPOS front panel

 

The following table describes the LEDs on the front panel.

Table 216 RT-XMIM-1CPOS LED description

LED

Status

Description

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified or the firmware is being updated.

Flashing green (1 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Steady yellow

The interface module has failed to complete initialization.

Off

The interface module has not been identified or has been removed.

ACT/ALM

Steady green

A link is present on the port.

Flashing green

The interface is receiving or sending data.

Steady yellow

A transceiver module has been installed in the interface, while an alarm is present on the interface.

Off

No transceiver module has been installed in the interface.

 

Transceiver modules, optical fibers, and connection methods

For more information about the transceiver modules, optical fibers, and connection methods, see "Fiber port."

E1 interface modules

·     RT-XMIM-2E1

·     RT-XMIM-4E1

·     RT-XMIM-8E1

RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1

When the RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1 interface module changes to the fractional E1 (E1-F) mode, the interface module name displayed from the command output on the device will be changed to RT-XMIM-2E1-F/RT-XMIM-4E1-F/RT-XMIM-8E1-F accordingly.

Introduction

The RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1 is a 2/4/8-port XMIM module that can operate in channelized E1 (CE1/PRI) mode or fractional E1 (E1-F) mode.

·     In channelized E1 (CE1/PRI) mode, the module can group the 31 channels in multiple ways to achieve different bundling configurations. Its primary function is to receive, transmit, and process E1 data streams while also providing CE1 access. In addition, it supports also ISDN PRI. These features enable multiple purposes to be achieved on a single module.

·     In non-channelized E1 mode, the module functions as a synchronous serial port with a data bandwidth of 2.048 Mbps and no timeslot division.

·     In fractional E1 (E1-F) mode, the module can only be bundled once (into a single channel with a speed of n × 64K, where n = 1 to 31), and does not support PRI mode.

Interface specifications

The following table describes the interface specifications of the module.

Table 217 RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1 interface specifications

Item

Description

RT-XMIM-2E1

RT-XMIM-4E1

RT-XMIM-8E1

Connector type

RJ-45

RJ-45

RJ-45

Number of connectors

2

4

8

Interface standard

G.703

Interface speed

2.048 Mbps

Cable

E1 120-ohm balanced twisted-pair cable (2m,15m, 30m)

E1 75-ohm unbalanced coaxial cable

75-ohm 8E1 repeater cable

Coaxial connector, network interface connector, and 75-ohm to 120-ohm adapter (with BNC connector)

Operating mode

Non-channelized E1(G.703)

Channelized E1 (CE1/PRI)

Fractional E1 (E1-F)

Supported services

Backup

Endpoint access service

ISDN PRI

 

 

NOTE:

The E1 cable after extension supports a maximum transmission distance of 100 m (328.08 ft).

 

Front panel and LEDs

The RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1 front panels are as shown in the following figures.

Figure 173 RT-XMIM-2E1 module front panel

 

Figure 174 RT-XMIM-4E1 module front panel

 

Figure 175 RT-XMIM-8E1 module front panel

 

The module provides a green and a yellow LED for each interface.

Table 218 RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1 LED description

LED

Status

Description

LINK/ACT (green)

Steady green

Carrier signals are received.

Flashing green

The interface is sending or receiving data.

Off

No carrier signals are received.

LP/AL (yellow)

Steady yellow

The interface is in a loopback state.

Flashing yellow

The interface does not have a cable connected, the cable is faulty, or the peer device is faulty.

Off

No loopback or alarm is present.

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified.

Flashing green (8 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Steady yellow

The interface module has failed to complete initialization.

Off

The interface module has not been identified or has been removed.

 

Jumper caps

The RT-XMIM-2E1/RT-XMIM-4E1/RT-XMIM-8E1 interface module provides jumper caps, the installation status of which determines the interface impedance. By default, each pin pair is installed with a jumper cap and the impedance of an E1 interface is 75 ohms.

To connect a 120-ohm cable to an E1 interface, remove the jumper caps from the pins corresponding to the interface.

Figure 176 Default installation status of jumper caps (RT-XMIM-8E1 as an example)

 

Every two interfaces on the interface module correspond to a jumper connector, and the pin settings are the same for the jumper connectors. You can set different impedance modes for the interfaces. For example, an RT-XMIM-8E1 interface module has four jumper connectors, with each jumper connector corresponding to two interfaces. The pins on a jumper connector are numbered PIN1 through PIN14. To set the impedance to 75 ohms for E1 interface 0, install jumper caps on pins 1 and 2, pins 3 and 4, and pins 5 and 6. To connect a 120-ohm cable to the E1 interface, remove the jumper caps from these pins. Table 219 displays the mapping relations between pins on jumper connectors and E1 interfaces.

Table 219 Mapping relations between pins on jumper connectors and E1 interfaces

Jumper connector

Pins

E1 interface

Supported interface modules

1

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 0

RT-XMIM-2E1

RT-XMIM-4E1

RT-XMIM-8E1

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 1

Pins 13 and 14

Keep the jumper cap in its default installation status

2

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 2

RT-XMIM-4E1

RT-XMIM-8E1

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 3

Pins 13 and 14

Keep the jumper cap in its default installation status

3

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 4

RT-XMIM-8E1

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 5

Pins 13 and 14

Keep the jumper cap in its default installation status

4

Pins 1 and 2, pins 3 and 4, pins 5 and 6

E1 interface 6

RT-XMIM-8E1

Pins 7 and 8, pins 9 and 10, pins 11 and 12

E1 interface 7

Pins 13 and 14

Keep the jumper cap in its default installation status

 

Interface cables and the connection methods

For more information about E1 interface cables and the connection methods, see "E1 interface.”

Network data encryption modules

RT-XMIM-CNDE-SJK

Introduction

RT-XMIM-CNDE-SJK is an SCA SM encryption XMIM module. It supports SM1, SM3, and SM4 encryption algorithms, providing high-performance and high-reliability encryption features for routers.

Interface LEDs

Figure 177 RT-XMIM-CNDE-SJK panel

 

Table 220 RT-XMIM-CNDE-SJK LED description

LED

Status

Description

RUN

Steady green

The interface module is operating correctly.

Flashing green (8 Hz)

The interface module is being identified.

Flashing green (1 Hz)

The device has successfully identified the interface module and has begun initializing the interface module.

Flashing yellow (8 Hz)

The interface module resource is being released.

Steady green

The interface module has failed to complete initialization.

Off

·     The interface module has not been identified or has been removed.

·     The interface module can be removed.

 

SSD modules

CAUTION

CAUTION:

The RT-SSD-960G SSD module can be hot-swapped. To remove an RT-SSD-960G SSD module on an operating device, first press and hold the remove button until the RUN LED is off.

 

RT-SSD-960G

Introduction

The RT-SSD-960G is a 960GB SSD module, which is mainly used for storage services.

Interface specifications

Table 221 Interface specifications

Item

Description

Connector

SATA

Capacity

960 GB

Interface rate

3 Gbps

 

Interface LEDs

Figure 178 RT-SSD-960G panel

 

Table 222 LED description

LED

Status

Description

RUN

Steady green

The module is operating correctly.

Flashing green (eight times per second)

The module is being identified.

Flashing yellow  (eight times per second)

The module resource is being released.

Steady yellow

The module has failed to complete initialization.

Off

·     The module has not been identified or has been removed.

·     The module can be removed.

 


Cables and the connection methods

Ethernet interface

Ethernet cable appearance and applicable models

Table 223 Ethernet cable appearance and applicable models

Appearance

Applicable models

1 × RJ-45 < ---- > 1 × RJ-45

SIC-4FSW

SIC-4FSWP

SIC-4GSW

RT-SIC-4GSW-G

DSIC-9FSW

DSIC-9FSWP

SIC-1FEA

SIC-1GEC-V2

SIC-AP220

HMIM-8GSW

HMIM-24GSW

HMIM-24GSW-PoE

HMIM-2GEE

HMIM-4GEE

HMIM-8GEE

RT-HMIM-4GEE-V2

RT-HMIM-8GEE-V2

RT-HMIM-4GEE-V2-G

RT-HMIM-8GEE-V2-G

HMIM-1E1POS

DHMIM-1DM

DHMIM-1E1POS1DM

RT-XMIM-8GEE-R

 

10/100 Mbps Ethernet uses category-5 twisted pair cables, and 1000 Mbps Ethernet uses category-5 enhanced or category-6 twisted pair cables. Twisted pair cables include straight-through cables and crossover cables.

Category-5 cables provide a transmission frequency of 100 MHz for voice and data transmission; they are mainly used in 100BASE-T and 10BASE-T networks. Category-5 cables are common Ethernet cables, which can also be used to transmit 1000 Mbps Ethernet data.

Category-5 enhanced cables feature low attenuation and crosstalk, providing higher attenuation to crosstalk ratio (ACR), less delay error and higher performance than category-5 cables. Category-5 enhanced cables are mainly used in 1000 Mbps Ethernet networks.

Category-6 cables provide a transmission frequency of 1 MHz to 250 MHz, and improve the performance on crosstalk and return loss. A fine better return loss performance is extremely important for new-generation full-duplex high-speed networks. Category-6 cables have sufficient power sum ACR (PS-ACR) when working at 200 MHz. They provide a bandwidth two times than that of category-5 enhanced cables, thus featuring a higher transmission performance. Therefore, category-6 cables are suitable for applications requiring a transmission speed of more than 1 Gbps.

The 10/100 Mbps Ethernet uses two pairs of cables, orange/white, orange, green/white and green cables, to transmit and receive data, while the 1000 Mbps Ethernet uses four pairs of cables to transmit and receive data.

For the pinouts of common twisted pair cables, see the following tables. (A and B represent the two ends of a cable respectively.)

Table 224 Straight-through cable pinouts

Pinout No.

A

B

1

Orange/white

Orange/white

2

Orange

Orange

3

Green/white

Green/white

4

Blue

Blue

5

Blue/white

Blue/white

6

Green

Green

7

Brown/white

Brown/white

8

Brown

Brown

 

Table 225 Crossover cable pinouts

Pinout No.

A

B

1

Orange/white

Green/white

2

Orange

Green

3

Green/white

Orange/white

4

Blue

Blue

5

Blue/white

Blue/white

6

Green

Orange

7

Brown/white

Brown/white

8

Brown

Brown

 

 

NOTE:

Strictly follow the pinouts in the above tables when identifying or making the two types of Ethernet cables; otherwise, the communication quality may be affected.

 

Connecting an Ethernet cable

1.     Connect one end of an Ethernet cable to an Ethernet interface on the module and the other end to the Ethernet interface on the peer device. Because the Ethernet interface of the module supports MDI/MDIX autosensing, you can use a straight-through cable or crossover cable to connect the interface.

2.     Check the status of the LED of the Ethernet interface after power-on. For the status of the LED, see the relevant part in this manual.

Fiber port

Appearances and applicable models of transceiver modules and optical fibers

Optical interfaces must work with SFP or SFP+ transceiver modules and optical fibers with LC connectors. For more information about interface module and transceiver module compatibility, see H3C MSR Router Series Transceiver Module Compatibility Matrix.

Connecting an optical fiber

CAUTION

CAUTION:

·     Never stare into an open optical Ethernet interface, because invisible rays may be emitted from the optical Ethernet interface.

·     Cover the dust cover if no optical fiber connector is connected to the optical Ethernet interface.

 

To connect an optical fiber:

1.     Insert the transceiver module to the interface on the interface module or service module.

2.     Identify the Rx and Tx ports on the transceiver module. Plug the LC connector at one end of one fiber cable into the Rx port of the router and the LC connector at the other end into the Tx port of the peer device. Plug the LC connector at one end of another fiber cable into the Tx port of the router and the LC connector at the other end to the Rx port of the peer device.

3.     View the LINK LED after connection.

¡     If the LED is on, the optical fiber link is present.

¡     If the LED is off, no link is present. This may be because the TX and Rx port of the optical fiber are not connected correctly. In this case, connect the optical fiber again.

E1 interface

To verify the impedance value of the E1 cable, view the label on the cable. The label location in Figure 179 is for illustration only.

Figure 179 E1 cable label

 

E1 cable appearance and applicable models

Table 226 E1 cable appearance and applicable models

Cable

Appearance

Applicable models

1-port E1 75-ohm cable

图一 1端口E1 75欧姆电缆

1 × D15 < ---- > 2 × BNC

SIC-E1-F

SIC-1EPRI

MIM-1E1

MIM-1E1-F

MIM-2E1

MIM-2E1-F

HMIM-1E1

HMIM-1E1-F

HMIM-2E1

HMIM-2E1-F

SIC-1VE1

MIM-1VE1

MIM-2VE1

HMIM-1VE1

HMIM-2VE1

1-port E1 120-ohm cable

图二   1端口E1 120欧姆电缆

1 × D15 < ---- > 1 × RJ-45

MIM-1E1

MIM-1E1-F

MIM-2E1

MIM-2E1-F

HMIM-1E1

HMIM-1E1-F

HMIM-2E1

HMIM-2E1-F

SIC-1VE1

MIM-1VE1

MIM-2VE1

HMIM-1VE1

HMIM-2VE1

1-port E1 120-ohm cable (2 m, 15 m, 30 m)-RJ-45

1 × RJ-45 < ---- > 1 × RJ-45

RT-HMIM-2E1-V3

RT-HMIM-4E1-V3

RT-HMIM-8E1-V3

HMIM-2E1T1

HMIM-4E1T1

HMIM-8E1T1

HMIM-2E1T1-F

HMIM-4E1T1-F

HMIM-8E1T1-F

SIC-1VE1T1

RT-SIC-2E1-G

RT-XMIM-2E1

RT-XMIM-4E1

RT-XMIM-8E1

2-port E1 75-ohm cable

图三  2端口E1 75欧姆电缆

1 × D15 < ---- > 4 × BNC

SIC-2E1-F

4-port E1 75-ohm cable

图四  4端口E1 75欧姆电缆

1 × D25 < ---- > 4 × D15

MIM-4E1

MIM-4E1-F

HMIM-4E1

HMIM-4E1-F

4-port E1 120-ohm cable

图五  4端口E1 120欧姆电缆

1 × D25 < ---- > 4 × D15

MIM-4E1

MIM-4E1-F

HMIM-4E1

HMIM-4E1-F

8-port E1 75-ohm cable

1 × D68 < ---- > 16 × BNC

MIM-8E1

MIM-8E1-F

HMIM-8E1(75)

HMIM-8E1(75)-F

1-port E1 75-ohm cable-RJ-45

RT-HMIM-2E1-V3

RT-HMIM-4E1-V3

RT-HMIM-8E1-V3

HMIM-2E1T1

HMIM-4E1T1

HMIM-8E1T1

HMIM-2E1T1-F

HMIM-4E1T1-F

HMIM-8E1T1-F

SIC-1VE1T1

RT-SIC-2E1-G

RT-XMIM-2E1

RT-XMIM-4E1

RT-XMIM-8E1

75-ohm adapter cable

图六  75欧姆中继电缆

1 × BNC < ---- > 1 × BNC

Use as needed

Coaxial connector

图七  同轴连接器

1 × BNC < ---- > 1 × BNC

Use as needed

Impedance converter

图八 阻抗转换器

2 × BNC < ---- > 1 × RJ-45

Use as needed

 

Dual inline package switch

E1 / E1-F / VE1 interface module provides a dual inline package (DIP) switch. The DIP switch setting defines the interface impedance and the grounding method.

Table 227 DIP switch-to-interface map

DIP switch

E1 interface

Applicable models

S1

Interface 0

MIM-1E1

MIM-1E1-F

MIM-2E1

MIM-2E1-F

MIM-4E1

MIM-4E1-F

HMIM-1E1

HMIM-1E1-F

HMIM-2E1

HMIM-2E1-F

HMIM-4E1

HMIM-4E1-F

SIC-1VE1

MIM-1VE1

MIM-2VE1

HMIM-1VE1

HMIM-2VE1

S2

Interface1

MIM-1E1

MIM-1E1-F

MIM-2E1

MIM-2E1-F

MIM-4E1

MIM-4E1-F

HMIM-1E1

HMIM-1E1-F

HMIM-2E1

HMIM-2E1-F

HMIM-4E1

HMIM-4E1-F

MIM-2VE1

HMIM-2VE1

S3

Interface2

MIM-4E1

MIM-4E1-F

HMIM-4E1

HMIM-4E1-F

S4

Interface3

MIM-4E1

MIM-4E1-F

HMIM-4E1

HMIM-4E1-F

 

By default, all DIP switches are ON, and the E1 interface impedance is 70 ohms, as shown in the following figure:

Figure 180 Default DIP switch settings

 

H3C recommends that you use the DIP switch as follows: When the interface is connected to a 70-ohm cable, turn on switches BIT1 through 8; when the interface is connected to a 120-ohm cable, turn off switches BIT1 through 8. Description for DIP switch settings is shown in the following table:

Table 228 Description for DIP switch settings

DIP

Description

Configuration of 75-ohm impedance

Configuration of 120-ohm impedance

1BIT

75-ohm/120-ohm selection switch

ON

Off

2BIT

ON

Off

3BIT

ON

Off

4BIT

ON

Off

5BIT

ON

Off

6BIT

RxRing grounding mode selection switch

Off: RxRing is grounded via capacitance.

ON: RxRing is grounded directly.

N/A

7BIT

RxShield grounding mode selection switch

N/A

ON: RxShield is grounded.

Off: RxShield is not grounded.

8BIT

SxShield grounding mode selection switch

N/A

Off: RxShield is grounded via capacitance

ON: RxShield is grounded directly.

 

Connecting a 1/2/8-port E1 75-ohm cable (D15/D68 <----> BNC)

CAUTION

CAUTION:

Make sure you insert the cable into the right interface so as to avoid damages to the interface module or the chassis.

 

·     If you do not need to extend the cable, you can directly connect the BNC connectors of the E1 75-ohm cable to the remote network device as follows:

a.     Connect the D15/D68 connector of the E1 75-ohm cable to the D15/D68 interface of the interface module and fasten the bolts to fix the cable.

b.     The other end of the cable provides one pair or multiple pairs of 75-ohm BNC connectors. Connect the TX connectors and the RX connectors on this end to the RX connectors and the TX connectors on the remote device respectively.

Figure 181 Connect an E1 75-ohm cable

 

·     If you want to extend the cable, connect each BNC connector of the E1 75-ohm cable to one end of a coaxial connector, and connect the remote device to the other end of the coaxial connector through an E1 75-ohm adapter cable.

Figure 182 Connect an E1 75-ohm cable

 

·     If the impedance of the E1 interface on the remote device is 120 ohms, you must use an impedance converter to adapt the impedance.

Figure 183 Connect an impedance converter

 

Connecting a 4-port E1 75-ohm cable (D25 <----> D15)

1.     Connect the D25 connector of the 4-port E1 75-ohm cable to the D25 interface of the interface module and fasten the bolts to fix the cable.

2.     The other end of the cable provides four D15 connectors. Connect them to the D15 interfaces on the remote device as needed.

Figure 184 Connect an 4-port E1 75-ohm cable

 

Connecting a 1-port E1 120-ohm cable (D15 <----> RJ-45)

1.     Connect the D15 connector of the E1 120-ohm cable to the D15 interface on the interface module and fasten the bolts to fix the cable.

2.     The other end of the cable provides one or multiple RJ-45 connectors. Connect them to the RJ-45 interface on the remote device as needed.

Figure 185 Connecting an E1 120-ohm cable

 

Table 229 DB15 to BNC/RJ-45 pinouts

DB15

BNC (75-ohm coaxial cable)

RJ-45 (120-ohm twisted pair cable)

9

Tx Tip

Tx Tip

4

Tx Tip

2

Tx Ring

Tx Ring

5

Tx Ring

10

Tx Shield

N/A

6

Tx Shield

8

Rx Tip

Rx Tip

1

Rx Tip

15

Rx Ring

Rx Ring

2

Rx Ring

7

Rx Shield

N/A

3

Rx Shield

 

Connecting a 4-port E1 120-ohm cable (D25 <----> D15)

1.     Connect the D25 connector of the 4-port E1 120-ohm cable to the D25 interface on the interface module and fasten the bolts to fix the cable.

2.     The other end of the cable provides four D15 connectors. Connect them to the D15 interface on the remote device as needed.

Figure 186 Connecting a 4-port E1 120-ohm cable

 

T1 interface

CAUTION

CAUTION:

To avoid damages to the interface module or the chassis, make sure you insert the cable into the right interface.

 

T1 cable appearance and applicable models

Table 230 T1 cable appearance and applicable models

Cable

Appearance

Applicable models

1-port T1 cable (100- ohm standard shielded cable)

1 × RJ-45 < ---- > 1 × RJ-45

SIC-T1-F

MIM-2T1

MIM-4T1-F

HMIM-2T1

HMIM-4T1-F

SIC-1VT1

SIC-1VE1T1

MIM-1VT1

MIM-2VT1

HMIM-1VT1

HMIM-2VT1

HMIM-2E1T1

HMIM-4E1T1

HMIM-8E1T1

HMIM-2E1T1-F

HMIM-4E1T1-F

HMIM-8E1T1-F

RJ-45 connector

图十八 RJ45连接器

1 × RJ-45 < ---- > 1 × RJ-45

Use as needed

 

Connecting a 1-port T1 cable

The two ends of the 1-port T1 cable are RJ-45 connectors. Connect one end of the cable to the T1 connector (RJ-45) of the interface module and the other end of the cable to the T1 connector (RJ-45) on the remote device.

 

Connecting a 4/8-port T1 cable

·     Connect the D68 connector of the 4/8-port T1 cable to the D68 interface on the interface module and fasten the bolts to fix the cable.

·     The other end of the cable provides four or eight RJ-45 connectors. Connect them to the RJ-45 interface on the remote device as needed.

E3/T3 interface

E3/T3 cable appearance and applicable models

Table 231 E3/T3 cable appearance and applicable models

Cable

Appearance

Applicable models

E3/T3 interface cable

1 × BNS < ---- > 1 × SMB

MIM-1CE3

HMIM-1CE3

 

Connecting the cable

1.     Connect the SMB connector of an E3/T3 cable to the Tx port on the interface module and the other end to the Rx port on the device to be connected.

2.     Connect the SMB connector of another E3/T3 cable to the Rx port of interface module and the other end to the Tx port on the device to be connected;

3.     Check the LINK LED on the module panel. It is off when fault has occurred on the link and signal is out of synchronization. In this case, check the link.

Synchronous/asynchronous serial ports

Appearance and applicable models of synchronous/asynchronous serial port cables

Table 232 Appearance and applicable models of synchronous/asynchronous serial port cables

Cable

Appearance

Applicable models

V.24 DTE cable

1 × D25 (male) < ---- > 1 × D28

SIC-1SAE

SIC-2SAE

SIC-4SAE

MIM-2SAE

MIM-4SAE

MIM-8SAE

HMIM-2SAE

HMIM-4SAE

HMIM-8SAE

RT-HMIM-4SAE-V2

RT-HMIM-8SAE-V2

V.24 DCE cable

1 × D25 (female) < ---- > 1 × D28

V.35 DTE cable

1 × D28 < ---- > 1 × D34 (male)

V.35 DCE cable

1 × D28 < ---- > 1 × D34 (female)

X.21 DTE cable

1 × D15 (male) < ---- > 1 × D28

X.21 DCE cable

1 × D15 (female) < ---- > 1 × D28

RS-449 DTE cable

1 × D28 < ---- > 1 × D37 (male)

RS-449 DCE cable

1 × D28 < ---- > 1 × D37 (female)

RS-530 DTE cable

1 × D25 (male) < ---- > 1 × D28

RS-530 DCE cable

1 × D25 (female) < ---- > 1 × D28

 

Connecting the cable

1.     Check port type of the peer device and choose the synchronous serial interface cable of correct type.

2.     Plug the D28 end of the synchronous serial interface cable into the D28 interface of the SAE interface module.

3.     If the WAN uses DDN line, connect the cable to the port of CSU/DSU.

4.     Check the LINK LED on the SAE panel.

¡     If the LED is on, a link is present.

¡     If the LED is off, a fault has occurred on the link and signal is out of synchronization. In this case, check the link.

Asynchronous serial ports

Appearance and applicable models of asynchronous serial port cables

Table 233 Appearance and applicable models of asynchronous serial port cables

Cable

Appearance

Applicable models

8-port asynchronous serial port adapter cable

图九 8端口异步串口转接电缆

1 × D60 < ---- > 8 × RJ-45 (female)

SIC-8AS

4-port asynchronous serial port adapter cable

图十  4端口异步串口转接电缆

1 × D28 < ---- > 4 × RJ-45 (female)

SIC-16AS

Serial server cable

1 × RJ-45 < ---- > 1 × RJ-45

MIM-8ASE

MIM-16ASE

HMIM-8ASE

HMIM-16ASE

RT-HMIM-8ASE-V2

RT-HMIM-16ASE-V2

Dumb terminal adapter cable

图十一  哑终端转接电缆

1 × RJ-45 (female) < ---- > 1 × RJ-45 (male)

MIM-8ASE

MIM-16ASE

HMIM-8ASE

HMIM-16ASE

RT-HMIM-8ASE-V2

RT-HMIM-16ASE-V2

AUX cable

图十二  AUX电缆

1 × D25 & 1 × D9 < ---- > 1 × RJ-45

MIM-8ASE

MIM-16ASE

HMIM-8ASE

HMIM-16ASE

RT-HMIM-8ASE-V2

RT-HMIM-16ASE-V2

Dumb terminal adapter

图十九 哑终端转接器

1 × D25 < ---- > 1 × RJ-45

MIM-8ASE

MIM-16ASE

HMIM-8ASE

HMIM-16ASE

RT-HMIM-8ASE-V2

RT-HMIM-16ASE-V2

Console cable

1 × DB-9 < ---- > 1 × RJ-45

SIC-AP220

SIC-AP320

 

Connecting a SIC-8AS/SIC-16AS interface module

To connect the SIC-8AS interface module, connect the D60 connector of the 8-port asynchronous serial port adapter cable to the SIC-8AS interface module.

To connect the SIC-16AS interface module, connect the D28 connector of the 4-port asynchronous serial port adapter cable to the SIC-16AS interface module, which allows up to four such cables.

Choose the cable connection type according to the remote device type:

·     If the remote device is a network device with a console port, connect the console port to the RJ-45 interface of the asynchronous serial port adapter cable by using a serial server cable. The sequence is shown in the following figure:

Figure 187 Connecting a network device

 

·     If the remote device is a bank dumb terminal device, connect the RJ-45 connector (male) on one end of the dumb terminal cable to the RJ-45 interface on the asynchronous serial port adapter cable. Connect the RJ-45 connector (female) on the other end of the dumb terminal cable to the RJ-45 interface on one end of the dumb terminal adapter by a straight-through cable. The other end of the dumb terminal adapter is a D25 interface and can be connected to the bank dumb terminal device. The sequence is shown in the following figure:

Figure 188 Connecting the dumb terminal device

 

·     If the interface of the remote device, usually a modem, is a D25/D9 interface, use the AUX cable to connect the asynchronous serial port adapter cable to the interface:

Figure 189 Connecting a modem

 

Connecting a MIM-8ASE/MIM-16ASE/HMIM-8ASE/HMIM-16ASE/RT-HMIM-8ASE-V2/RT-HMIM-16ASE-V2 interface module

WARNING

WARNING!

To avoid damage to the device and the ports, do not plug or unplug the MIM-8ASE/MIM-16ASE module interface cable when the router is powered on.

 

CAUTION

CAUTION:

To avoid damages to the interface module or the chassis, make sure you insert the cable into the right interface.

 

Choose the cable connection type according to the remote device type:

·     If the remote device is a network device with a console port, connect the console port to the RJ-45 interface of the interface module by using a serial server cable. The sequence is shown in the following figure:

Figure 190 Connecting a network device

 

·     If the remote device is a bank dumb terminal device, connect the RJ-45 connector (male) on one end of the dumb terminal cable to the RJ-45 interface on the interface module. Connect the RJ-45 connector (female) on the other end of the dumb terminal cable to the RJ-45 interface on one end of the dumb terminal adapter by a straight-through cable. The other end of the dumb terminal adapter is a D25 interface and can be connected to the bank dumb terminal device. The sequence is shown in the following figure:

Figure 191 Connecting a bank dumb terminal device

 

·     If the interface of the remote device, usually a modem, is a D25/D9 interface, use the AUX cable to connect the RJ-45 interface on the interface module. The sequence is shown in the following figure:

Figure 192 Connecting a modem

 

Connecting a SIC-AP220/SIC-AP320 WLAN interface module

To connect the interface module to a configuration terminal (for example, a PC) through the serial console cable:

1.     Connect the DB-9 female connector of the console cable to the serial port of the PC

2.     Connect the RJ-45 connector to the console port on the module.

To disconnect the console cable, remove the RJ-45 connector end first.

ADSL/BS/FXS/FXO/AM/FCM interface

Appearance and applicable models of the magnetic-core telephone cable

Table 234 Appearance and applicable models of magnetic-core telephone cable

Cable

Appearance

Applicable models

Magnetic-core telephone cable

图十三  带磁环的电话线

1 × RJ-11 < ---- > 1 × RJ-11

SIC-1ADSL

SIC-1ADSL-I

SIC-1BS

SIC-2BS

SIC-1FXS

SIC-1FXO

SIC-2FXS

SIC-2FXO

SIC-2FXS1FXO

DSIC-4FXS1FXO

SIC-1AM

SIC-2AM

MIM-4FXS

MIM-4FXO

MIM-16FXS

MIM-8FXS8FXO

HMIM-4FXS

HMIM-4FXO

HMIM-16FXS

HMIM-8FXS8FXO

HMIM-6AM

HMIM-6FCM

 

Connecting an ADSL/FXS/FXO/AM/FCM interface module

1.     Connect one end of the magnetic-core telephone cable to the RJ-11 or RJ-45 interface of the interface module.

2.     Connect the other end of the magnetic-core telephone cable to the remote device interface.

Connecting a BS/BU interface module cable

1.     If the service provider provides an ISDN U interface cable, you must use an NT1 device for adaptation. Connect one end of the magnetic-core telephone cable to the RJ-45 interface of the SIC-1BS interface module. Connect the other end of the magnetic-core telephone cable to the S/T interface of the NT1 device. Connect the ISDN U interface cable to the U interface on the NT1 device.

Figure 193 Connecting the U interface cable to the SIC-1BS interface module

 

2.     If the service provider provides an ISDN S/T interface cable, directly connect the cable to the RJ-45 interface of the SIC-1BS interface module.

Figure 194 Connecting the S/T interface cable to the SIC-1BS interface module

 

E&M interface

E&M interface appearance and the applicable model

MIM-4E&M and FIC-4E&M modules support Bell I, II, III, V switches, and 2-wire & 4-wire voice signals.

As a best practice, use Bell V 4-wire voice signal to communicate with the router in practice.

The sequence of E&M RJ-45 pins is shown in the following figure, numbered 1 to 8 from left to right:

Figure 195 Sequence of RJ-45 pins

 

Table 235 Pinouts of E&M interface cable (Bell V 4-wire)

E&M interface

RJ-45 Pin

Signal

Signal direction

1

2

E

IN

3

RING0

IN

4

RING1

OUT

5

TIP1

OUT

6

TIP0

IN

7

M

OUT

8

SG

Ground

 

 

NOTE:

Because the 4E&M modules cannot determine the interface types (Bell I/II/III/V), cable types (2-wire or 4-wire), and pinouts (E/M/Tx/Rx) of the peer switch, you must prepare the interface cables of the 4E&M modules according to the on-site conditions. To ensure the EMC of the router, install a ferrite core near the connector of the E&M module interface cable at the router side.

 

The connection method

1.     Connect one end of the magnetic-core telephone cable to the RJ-11 or RJ-45 interface of the interface module.

2.     Connect the other end of the magnetic-core telephone cable to the remote device interface.

BSV/BSE interface

BSV/BSE interface cable appearance and applicable models

Table 236 BSV/BSE interface cable appearance and applicable models

Cable

Appearance

Applicable models

ISDN S/T interface standard cable

1 × RJ-45 < ---- > 1 × RJ-45

SIC-1BSV

SIC-2BSV

ISDN S/T interface crossover cable

图十一  哑终端转接电缆

1 × RJ-45 (female) < ---- > 1 × RJ-45 (male)

SIC-1BSV

SIC-2BSV

 

Connecting a SIC-1BSV / SIC-2BSV / MIM-4BSV interface module cable

BSV interface supports the User and Network operating modes. The BSV interface works in User mode when connecting to an ISDN network, or works in Network mode when connecting to TE devices such as the digital telephones or the BSV interfaces working in User mode.

Choose the cable connection type according to the operating mode:

·     When the BSV interface works in User mode, choose the connection method according to the type of the cable provided by the service provider:

¡     If the service provider provides an ISDN U interface cable, you must use an NT1 device for adaptation. Connect one end of the standard ISDN S/T interface cable to the RJ-45 interface of the BSV interface module. Connect the other end of the standard ISDN S/T interface cable to the S/T interface of the NT1 device. Connect the ISDN U interface cable to the U interface on the NT1 device.

Figure 196 Connecting a service provider U interface cable to a BSV interface module

 

 

¡     If the service provider provides an ISDN S/T interface cable, directly connect the service provider cable to the BSV interface.

Figure 197 Connecting a service provider S/T interface cable to a BSV interface module

 

 

·     When the BSV interface works in Network mode, you must use an ISDN S/T interface crossover cable to connect the BSV interface to a TE device such as a digital telephone or a BSV interface working in User mode:

Connect the RJ-45 connector (male) of the ISDN S/T interface crossover cable to the RJ-45 interface on the BSV interface module. Connect the RJ-45 interface (female) of the standard ISDN S/T interface cable to one end of the standard ISDN S/T interface cable. Connect the S/T interface on the TE device to the other end of the standard ISDN S/T interface cable.

Figure 198 Connecting a TE device to a BSV interface module

 

3G interface

Appearance and applicable models of the SIC-3G-CDMA/SIC-3G-TD/SIC-3G-HSPA interface module antenna

Table 237 Appearance and applicable models of the SIC-3G-CDMA/SIC-3G-TD/SIC-3G-HSPA interface module antenna

Antenna and cable

Appearance

Applicable models

Antenna

TZD-EW618-04_页面_1_图像_0003

SIC-3G-CDMA

SIC-3G-TD

SIC-3G-HSPA

AUX cable

图十二  AUX电缆

1 × D25 & 1 × D9 < ---- > 1 × RJ-45

 

Table 238 The detailed specifications for the SIC-3G-CDMA/SIC-3G-TD/SIC-3G-HSPA interface module antenna

Item

Description

Frequency scope

824-960 MHz / 1710-2170 MHz

Voltage standing wave ratio

≤ 2

Input impedance

50 ohms

Gain

1.5 dBi

Polarization type

Vertical

Maximum input power

10 W

Interface

TNC-Male

Lightning protection

Direct current grounding

Height

153 mm (6.02 in)

Weight

26 g (0.92 oz)

Length

None

Color

Black

Operating temperature

–30 °C to +60 °C (–22°F to +140°F)

 

Connecting a SIC-3G-CDMA/SIC-3G-TD/SIC-3G-HSPA interface module antenna

1.     To install an antenna, adjust the angle of the antenna to 180º.

2.     Fasten the antenna onto the antenna port that has a MAIN mark. Avoid over-tightening. Make sure the antenna is vertical to the ground or ceiling to achieve the optimal coverage.

Connecting a SIC-3G-CDMA/SIC-3G-TD/SIC-3G-HSPA interface debug antenna

To debug and test the SIC-3G-CDMA/SIC-3G-TD/SIC-3G-HSPA, connect the RJ-45 interface of the AUX cable to the Diag Port interface and connect the D25/D9 connector to a peer device, which is usually a PC.

 

4G interface

Appearance and applicable models of 4G antennas and extension cables

Table 239 Appearance and applicable models of the 4G antennas and extension cables

Antenna and cable

Appearance

Applicable models

4G antenna

TZD-EW618-04_页面_1_图像_0003

SIC-4G-LTE-M

4G antenna

SIC-4G-CNDE/SIC-D4G-CNDE/SIC-4G-CNDE-SJK/SIC-D4G-CNDE-SJK

4G antenna

RT-SIC-4G-CAT6

4G antenna extension cable

SIC-4G-CNDE/SIC-D4G-CNDE/SIC-4G-CNDE-SJK/SIC-D4G-CNDE-SJK

4G antenna extension cable

cid:image005.jpg@01D68CDF.2C973130

RT-SIC-4G-CAT6

 

Table 240 Antenna specifications

Item

Specification

SIC-4G-LTE-M

SIC-4G-CNDE/SIC-D4G-CNDE/SIC-4G-CNDE-SJK/SIC-D4G-CNDE-SJK

RT-SIC-4G-CAT6

Frequency scope

698 to 960 MHz

1.71 to 2.7 GHz

791 to 960 MHz

1710 to 2690 MHz

617 to 960 MHz

1400 to 1612 MHz

1710 to 2170 MHz

2300 to 2700 MHz

3300 to 3800 MHz

4400 to 5000 MHz

5150 to 5850 MHz

Voltage standing wave ratio

2.5

≤ 3.5

≤ 4

Input impedance

50 ohms

50 ohms

50 ohms

Gain

2 dBi

791 to 960 MHz @ 3.1 dBi

1710 to 2690 MHz @ 7.2dBi

617 to 960 MHz/0.59 dBi

1400 to 1612 MHz/1.87 dBi

1710 to 2170 MHz/3.74 dBi

2300 to 2700 MHz/3.51 dBi

3300 to 3800 MHz/3.7 dBi

4400 to 5000 MHz/4.0 dBi

5150 to 5850 MHz/4.87 dBi

Polarization type

Vertical

Vertical

Vertical

Maximum input power

5 W

1 W

1 W

Interface

TNC

SMA

SMA, male

Height

21.4 cm (8.43 in)

16.6 cm (6.54 in)

20.3 cm (7.99 in)

Weight

50.5 g (1.78 oz)

22 g (0.78 oz)

19.63 g (0.69 oz)

Color

Black

Black

Black

Operating temperature

–40°C to +85°C (–40°F to +185°F)

–10°C to +60°C (14°F to 140°F)

–20°C to +60°C (–4°F to +140°F)

 

Table 241 4G antenna extension cable specifications for the SIC-4G-CNDE/SIC-D4G-CNDE/SIC-4G-CNDE-SJK/SIC-D4G-CNDE-SJK module

Item

Specification

Frequency scope

698 to 960 MHz

1710 to 2700 MHz

Voltage standing wave ratio

≤ 2.0

Input impedance

50 ohms

Gain

2.0 dBi

Polarization type

Vertical

Interface

SMA

Height

16.4 ± 0.2 cm (6.46 ± 0.08 in)

Weight

134 ± 5 g (4.73 ± 0.18 oz)

Color

Black

Cable length

200 ± 2 cm (78.74 ± 0.79 in)

Operating temperature

–40°C to +60°C (–40°F to +140°F)

 

Table 242 4G antenna extension cable specifications for the RT-SIC-4G-CAT6 module

Item

Specification

Frequency range

DC to 6 GHz

Voltage standing wave ratio

≤ 5

Input impedance

50 ohms

Cable type

RG-174

Max input power

1 W

Interface

SMA

Cable length

3000 mm (118.11 in)

Weight

65.3 g (2.30 oz)

Color

Black

Operating temperature

–40°C to +85°C (–40°F to +185°F)

 

Connection methods of 4G antennas and antenna extension cables

For how to install a 4G antenna and antenna extension cable for the SIC-4G-LTE-M, SIC-4G-CNDE, SIC-D4G-CNDE, SIC-4G-CNDE-SJK, or SIC-D4G-CNDE-SJK module, see H3C MSR 4G SIC Modules SIM Card&Antenna&Antenna Extension Cable Installation Guides.

For how to install a 4G antenna and antenna extension cable for the RT-SIC-4G-CAT6 module, see H3C MSR 4G SIC-4G-CAT6 Module SIM Card&Antenna&Antenna Extension Cable Installation Guides.

Installing a 4G interface debugging antenna

A 4G interface module has a Mini USB port to connect to the peer device through the USB console cable for third-party software to debug the 4G interface module. When the interface module is operating correctly, you do not need to connect the USB console cable.

To debug a 4G interface module, connect the port at one end of the USB console cable to the peer device (PC), and connect the other end to the Mini USB port on the interface module.

5G interface

Appearance and applicable models of stick antennas and antenna extension cables

Table 243 Appearance and applicable models of the antennas and extension cables

Name

Appearance

Applicable models

Stick antenna A

cid:image004.jpg@01D68CDF.2C973130

RT-SIC-5G

RT-SIC-5G-CN

Stick antenna B

RT-SIC-5G

RT-SIC-5G-CN

3 m (9.84 ft) antenna extension cable (with a magnetic antenna mount base)

cid:image005.jpg@01D68CDF.2C973130

RT-SIC-5G

RT-SIC-5G-CN

1 m (3.28 ft) antenna extension cable (with a magnetic antenna mount base)

RT-SIC-5G

RT-SIC-5G-CN

10 cm (3.94 in) cable

RT-SIC-5G

RT-SIC-5G-CN

5 m (16.40 ft)/10 m (32.81 ft) antenna extension cable

RT-SIC-5G

RT-SIC-5G-CN

Antenna bracket

RT-SIC-5G

RT-SIC-5G-CN

 

Table 244 Stick antenna A specifications

Item

Description

Frequency range

698 to 960 MHz

1710 to 2170 MHz

2300 to 2700 MHz

3300 to 3800 MHz

4400 to 5000 MHz

5150 to 5850 MHz

Voltage standing wave ratio

≤ 4

Input impedance

50 ohms

Gain

617 MHz to 960 MHz, 0.59 dBi

1710 MHz to 2170 MHz, 3.74 dBi

2300 MHz to 2700 MHz, 3.51 dBi

3300 MHz to 3800 MHz, 3.7 dBi

4400 MHz to 5000 MHz, 4.0 dBi

5150 MHz to 5850 MHz, 4.87 dBi

Polarization type

Vertical

Maximum input power

1 W

Interface

SMA male

Height

203 mm (7.99 in)

Weight

19.63 g (0.69 oz)

Color

Black

Operating temperature

–20 °C to +65 °C (–4°F to +149°F)

 

Table 245 Stick antenna B specifications

Item

Description

Frequency range

0.6 to 6 GHz

Voltage standing wave ratio

≤ 6

Input impedance

50 ohms

Gain (max.)

2.74 dBi @ 0.617 to 0.96 GHz

1.01 dBi @ 1.4 to 1.612 GHz

4.48 dBi @ 1.71 to 2.17 GHz

3.98 dBi @ 2.3 to 2.7 GHz

4.74 dBi @ 3.3 to 4.0 GHz

5.50 dBi @ 4.0 to 5.0 GHz

5.82 dBi @ 5.15 to 5.85 GHz

Polarization type

Vertical

Maximum input power

1 W

Interface

SMA male

Height

17.6 cm (6.93 in)

Weight

20 g (0.71 oz)

Color

Black

Operating temperature

–20°C to +70°C (–4°F to +158°F)

 

Table 246 3 m (9.84 ft) antenna extension cable (with a magnetic antenna mount base) specifications

Item

Specification

Frequency range

DC to 6 GHz

Voltage standing wave ratio

≤ 5

Input impedance

50 ohms

Cable type

RG-174

Max input power

1 W

Interface

SMA

Cable length

3000 mm (118.11 in)

Weight

65.3 g (2.30 oz)

Color

Black

Operating temperature

–40°C to +85°C (–40°F to +185°F)

 

Table 247 1 m (3.28 ft) antenna extension cable (with a magnetic antenna mount base) specifications

Item

Specification

Frequency range

DC to 6 GHz

Voltage standing wave ratio

≤ 1.7

Input impedance

50 ohms

Cable type

RG-174

Interface

SMA

Cable length

1 m (3.28 ft)

Weight

202 g (7.13 oz)

Color

Black

Operating temperature

–20°C to +70°C (–4°F to +158°F)

 

Table 248 10 cm (3.94 in) antenna extension cable specifications

Item

Specification

Frequency range

DC to 6 GHz

Voltage standing wave ratio

≤ 1.2 @ (3 GHz)

≤ 1.4 @ (3 to 6 GHz)

Input impedance

50 ohms

Cable type

RG-174

Interface

SMA

Cable length

10 cm (3.94 in)

Color

Black

Operating temperature

–40°C to +85°C (–40°F to +185°F)

 

Table 249 5 m (16.40 ft) antenna extension cable specifications

Item

Specification

Frequency range

DC to 6 GHz

Voltage standing wave ratio

< 1.2 @ (0.3 to 2.4 GHz)

< 1.4 @ (5 to 6 GHz)

Input impedance

50 ohms

Cable type

RG8

Interface

SMA

Cable length

5 m (16.40 ft)

Color

White

Operating temperature

–40°C to +85°C (–40°F to +185°F)

 

Table 250 10 m (32.81 ft) antenna extension cable specifications

Item

Specification

Frequency range

DC to 6 GHz

Voltage standing wave ratio

≤ 1.2 @ (2.4 GHz)

≤ 1.5 @ (5 to 6 GHz)

Input impedance

50 ohms

Cable type

RG8

Interface

SMA

Cable length

10 m (32.81 ft)

Color

White

Operating temperature

–40°C to +85°C (–40°F to +185°F)

 

Connection methods of stick antennas and antenna extension cables

Different antenna configuration schemes and installation methods are used depending on the required antenna extension cable length and application scenario. For more information, see H3C MSR 5G SIC Modules SIM Card&Antenna&Antenna Extension Cable Installation Guides.

GPS interface

Appearance and applicable models of the SIC-4G-CNDE/SIC-D4G-CNDE/SIC-4G-CNDE-SJK/SIC-D4G-CNDE-SJK interface module GPS antenna

Table 251 Appearance and applicable models of the 4G interface module GPS antenna

Antenna

Appearance

Applicable models

GPS antenna

SIC-4G-CNDE

SIC-D4G-CNDE

SIC-4G-CNDE-SJK

SIC-D4G-CNDE-SJK

 

Table 252 Antenna specifications

Item

Specification

Frequency scope

1575.42 ± 3 MHz

Voltage standing wave ratio

≤ 1.92

Input impedance

50 ohms

Gain

1.5 dBic Typ

Echo return loss

10 dB Min

Interface

SMA

Extension cable length

5 m (16.40 ft)

Extension cable type

RG-174 Coaxial Cable

Color

Black

Operating temperature

–30°C to +80°C (–22°F to +176°F)

 

Connecting an antenna extension cable

1.     Fasten the SMA connector onto the GPS antenna port on the module.

2.     Put the other end of the extension cable outdoor to achieve better signal coverage.

GNSS interface

Appearance and applicable models of the RT-SIC-4G-CAT6 module GNSS antenna

Table 253 Appearance and applicable models of the RT-SIC-4G-CAT6 module GNSS antenna

Antenna

Appearance

Applicable models

GNSS antenna

RT-SIC-4G-CAT6

 

Table 254 RT-SIC-4G-CAT6 module GNSS antenna specifications

Item

Specification

Frequency scope

·     1561±3 MHz

·     1575.42±3 MHz

·     1602±0.5 MHz

Operating mode

·     GPS

·     GLONASS

·     BDS

·     Galileo

Input impedance

50 ohms

Gain

–2.91 dBic Typ

Interface

SMA male

Extension cable length

5 m (16.40 ft)

Extension cable type

RG-174 coaxial cable

Color

Black

Operating temperature

–40°C to +85°C (–40°F to +185°F)

 

Connecting a GNSS antenna

1.     Fasten the SMA male connector of the antenna extension cable onto the GNSS antenna port on the module.

2.     Connect the other end of the extension cable to the antenna. Place the antenna outdoors for better signal receipt.

WLAN interface

Appearance and applicable models of the WLAN interface module antenna

Table 255 Appearance and applicable models of the WLAN interface module antenna

Antenna

Appearance

Applicable models

WLAN interface module antenna

天线渲染图

SIC-AP220

SIC-AP320

 

Connecting a WLAN interface module antenna

1.     Unfold the antenna.

2.     Attach the antenna to the antenna connector on the interface module. To avoid damage, do not over-tighten the antenna.

3.     Fold the antenna to a 90-degree angle so that it is vertical to the ground or ceiling to achieve optimal coverage.

 


Link mode of interfaces on Ethernet switching modules and interface modules

An interface can operate in bridge or route link mode. You can use the port link-mode command to change the link mode of an interface. Interfaces that operate in bridge mode are called Layer 2 interfaces. Interfaces that operate in route mode are called Layer 3 interfaces.

Some interfaces on Ethernet switching modules and interface modules can operate only as Layer 3 interfaces, as shown in Table 256. Some interfaces operate as Layer 2 interfaces by default but can be changed to Layer 3 interfaces by using the port link-mode command, as shown in Table 257.

 

IMPORTANT

IMPORTANT:

·     Interfaces on the SIC-4GSW or RT-SIC-4GSWF interface module can operate only in route link mode (Layer 3 interface mode) when the interface module is installed on an MSR3600-28-G-DP or MSR3600-51-G-DP router.

·     By default, the nine Ethernet interfaces on the DSIC-9FSW and DSIC-9FSWP interface modules operate in bridge mode. You can execute the port link-mode command to change the operating mode of any four interfaces to route. The remaining five interfaces can operate only in bridge mode.

·     When the SIC-4FSW, SIC-4FSWP, DSIC-9FSW, or DSIC-9FSWP interface module is installed on an MSR2600-10 or MSR2600-17 router, you can change the operating mode of any two interfaces to route. The remaining interfaces can operate only in bridge mode.

·     When the SIC-4FSW, SIC-4FSWP, DSIC-9FSW, or DSIC-9FSWP interface module is installed on other routers than MSR2600-10 and MSR2600-17 routers, you can change the operating mode of any four interfaces to route. The remaining interfaces can operate only in bridge mode.

·     For the interface module compatibility with router models, see "Appendix B  Purchase guide."

 

Table 256 Ethernet interfaces that can operate only as Layer 3 interfaces

Ethernet switching module/Ethernet interface module

Interfaces that can operate only as Layer 3 interfaces

SIC-4FSW

N/A

SIC-4FSWP

N/A

DSIC-9FSW

N/A

DSIC-9FSWP

N/A

SIC-4GSW

N/A

RT-SIC-4GSWF

N/A

SIC-1FEA

FE0

SIC-1FEF

SFP0

RT-SIC-4GSW-G

GE0 to GE3

RT-SIC-4GSWF-G

GE0 to GE3

RT-SIC-1XPF-G

GE0

SIC-1GEC-V2

Combo 0 (GE0, SFP0)

HMIM-8GSW

N/A

HMIM-24GSW

N/A

HMIM-24GSW-PoE

N/A

HMIM-8GSWF

N/A

HMIM-2GEE

GE0 and GE1

HMIM-4GEE

GE0 to GE3

HMIM-8GEE

GE0 to GE7

RT-HMIM-4GEE-V2

GE0 to GE3

RT-HMIM-8GEE-V2

GE0 to GE7

RT-HMIM-4GEE-V2-G

GE0 to GE3

RT-HMIM-8GEE-V2-G

GE0 to GE7

HMIM-2GEF

SFP0 and SFP1

HMIM-4GEF

SFP0 to SFP3

HMIM-8GEF

SFP0 to SFP7

RT-HMIM-4GEF-V2

SFP0 to SFP3

RT-HMIM-8GEF-V2

SFP0 to SFP7

RT-HMIM-4XP

SFP+0 to SFP+3

RT-XMIM-8GEE-R

GE0 to GE7

RT-XMIM-8GEF-R

SFP0 to SFP7

RT-XMIM-4XP

SFP+0 to SFP+3

 

Table 257 Ethernet interfaces that operate as Layer 2 interfaces by default and can be changed to Layer 3 interfaces

Ethernet switching module/Ethernet interface module

Interfaces that operate as Layer 2 interfaces by default and can be changed to Layer 3 interfaces

SIC-4FSW

FE0 to FE3

SIC-4FSWP

FE0 to FE3

DSIC-9FSW

Any four interfaces

DSIC-9FSWP

Any four interfaces

SIC-4GSW

GE0 to GE3

RT-SIC-4GSWF

SFP0 to SFP3

SIC-1FEA

N/A

SIC-1FEF

N/A

RT-SIC-4GSW-G

N/A

RT-SIC-4GSWF-G

N/A

SIC-1GEC-V2

N/A

RT-SIC-1XPF-G

N/A

HMIM-8GSW

GE0 to GE5, Combo 6 (GE6, SFP6), Combo 7 (GE7, SFP7)

HMIM-24GSW

GE0 to GE23

HMIM-24GSW-PoE

GE0 to GE23

HMIM-8GSWF

SFP0 to SFP3, Combo 4 (GE4, SFP4), Combo 5 (GE5, SFP5), Combo 6 (GE6, SFP6), Combo 7 (GE7, SFP7)

HMIM-2GEE

N/A

HMIM-4GEE

N/A

HMIM-8GEE

N/A

RT-HMIM-4GEE-V2

N/A

RT-HMIM-8GEE-V2

N/A

RT-HMIM-4GEE-V2-G

N/A

RT-HMIM-8GEE-V2-G

N/A

HMIM-2GEF

N/A

HMIM-4GEF

N/A

HMIM-8GEF

N/A

RT-HMIM-4GEF-V2

N/A

RT-HMIM-8GEF-V2

N/A

RT-HMIM-4XP

N/A

RT-XMIM-8GEE-R

N/A

RT-XMIM-8GEF-R

N/A

RT-XMIM-4XP

N/A

 

 

Frequency bands for 3G/4G/5G interface modules

IMPORTANT

IMPORTANT:

Support for each frequency band varies by mobile communication modem module model used by the interface module. The following tables are for your reference only.

 

Table 258 Frequency bands for 3G/4G/5G interface modules (1)

Interface module

CDMA

GSM

LTE-TDD

LTE-FDD

SIC-3G-CDMA

CDMA1x: BC0

N/A

N/A

N/A

SIC-4G-LTE-M

CDMA1x: BC0

B2/B3/B5/B8

B38/B39/B40/B41

B1/B3/B5/B7/B8

SIC-4G-CNDE

CDMA1x: BC0

B2/B3/B5/B8

B38/B39/B40/B41

B1/B3/B5/B7/B8

SIC-D4G-CNDE

CDMA1x: BC0

B2/B3/B5/B8

B38/B39/B40/B41

B1/B3/B5/B7/B8

RT-SIC-4G-CAT6

N/A

N/A

B38/B40/B41

B1/B3/B5/B7/B8/B20/B28/B32

RT-SIC-5G

N/A

N/A

B34/B38/B39/B40/B41/B42/B43/B48

B1/B2/B3/B4/B5/B7/B8/B12/B13/B14/B17/B18/B19/B20/B25/B26/B28/B29/B30/B32/B66/B71

RT-SIC-5G-CN

N/A

N/A

B34/B38/B39/B40/B41

B1/B2/B3/B5/B7/B8/B20/B28

 

Table 259 Frequency bands for 3G/4G/5G interface modules (2)

Interface module

TD-SCDMA

WCDMA

5G NR

LAA

SIC-3G-CDMA

N/A

N/A

N/A

N/A

SIC-4G-LTE-M

B34/B39

B1/B8

N/A

N/A

SIC-4G-CNDE

B34/B39

B1/B8

N/A

N/A

SIC-D4G-CNDE

B34/B39

B1/B8

N/A

N/A

RT-SIC-4G-CAT6

N/A

B1/B3/B5/B8

N/A

N/A

RT-SIC-5G

N/A

B1/B2/B3/B4/B5/B8/B19

NSA: n38/n41/n71/n77/n78/n79

SA: n1/n2/n3/n5/n7/n8/n12/n20/n25/n28/n38/n40/n41/n48/n66/n71/n77/n78/n79

B46

RT-SIC-5G-CN

N/A

B1/B2/B5/B8

NSA: n41/n78/n79

SA: n1/n28/n41/n77/n78/n79

N/A

 


Interface module net weights and power consumption

Table 260 Interface module net weights and power consumption

Interface module model

Net weight

Min power consumption

Max power consumption

DSIC-9FSW

N/A

N/A

3.20 W

DSIC-9FSWP

N/A

N/A

3.20 W

SIC-4GSW

0.10 kg (0.22 lb)

N/A

3.80 W

RT-SIC-4GSWF

0.10 kg (0.22 lb)

N/A

4.20 W

RT-SIC-4GSW-G

0.10 kg (0.22 lb)

2.30 W

3.91 W

RT-SIC-4GSWF-G

0.23 kg (0.51 lb)

1.88 W

3.97 W

SIC-1GEC-V2

0.10 kg (0.22 lb)

N/A

0.80 W

RT-SIC-1XPF-G

0.10 kg (0.22 lb)

10.42 W

10.43 W

RT-SIC-1POS-STM1

0.10 kg (0.22 lb)

N/A

8.40 W

SIC-E1-F

0.10 kg (0.22 lb)

N/A

0.40 W

SIC-2E1-F

0.10 kg (0.22 lb)

N/A

0.40 W

RT-SIC-2E1-G

0.15 kg (0.33 lb)

2.74 W

2.98 W

SIC-8AS

0.10 kg (0.22 lb)

N/A

3.40 W

SIC-16AS

0.10 kg (0.22 lb)

N/A

0.80 W

SIC-1SAE

N/A

N/A

0.42 W

SIC-2SAE

N/A

N/A

3.40 W

SIC-4SAE

N/A

N/A

3.40 W

SIC-4RS

0.10 kg (0.22 lb)

0.72 W

1.00 W

SIC-2FXS

N/A

N/A

2.00 W

SIC-2FXO

N/A

N/A

2.00 W

SIC-2FXS1FXO

N/A

N/A

2.40 W

SIC-1VE1T1

0.15 kg (0.33 lb)

N/A

4.00 W

SIC-3G-CDMA

N/A

N/A

3.40 W

SIC-3G-TD

N/A

N/A

3.40 W

SIC-3G-HSPA

N/A

N/A

3.40 W

SIC-4G-LTE-M

0.20 kg (0.44 lb)

N/A

5.00 W

SIC-4G-CNDE

0.15 kg (0.33 lb)

N/A

4.20 W

SIC-D4G-CNDE

0.10 kg (0.22 lb)

3.41 W

6.60 W

SIC-CNDE

N/A

N/A

5.50 W

SIC-CNDE-SJK

N/A

N/A

5.50 W

SIC-4G-CNDE-SJK

0.10 kg (0.22 lb)

N/A

6.60 W

SIC-D4G-CNDE-SJK

0.10 kg (0.22 lb)

N/A

4.20 W

RT-SIC-4G-CAT6

0.15 kg (0.33 lb)

2.79 W

4.80 W

RT-SIC-5G

0.25 kg (0.55 lb)

1.32 W

7.60 W

RT-SIC-5G-CN

0.25 kg (0.55 lb)

N/A

10.30 W

MIM-1ATM-OC3

N/A

N/A

5.80 W

HMIM-8GSW

0.70 kg (1.54 lb)

N/A

12.00 W

HMIM-24GSW

1.00 kg (2.20 lb)

4.76 W

22.40 W

HMIM-24GSW-PoE

N/A

N/A

22.40 W

HMIM-2GEE

0.60 kg (1.32 lb)

N/A

6.70 W

HMIM-4GEE

0.70 kg (1.54 lb)

N/A

6.90 W

HMIM-8GEE

0.60 kg (1.32 lb)

10.20 W

11.20 W

RT-HMIM-4GEE-V2

0.65 kg (1.43 lb)

8.97 W

9.10 W

RT-HMIM-8GEE-V2

0.70 kg (1.54 lb)

9.12 W

9.40 W

RT-HMIM-4GEE-V2-G

0.65 kg (1.43 lb)

N/A

12.00 W

RT-HMIM-8GEE-V2-G

0.70 kg (1.54 lb)

N/A

12.00 W

HMIM-2GEF

0.70 kg (1.54 lb)

N/A

6.70 W

HMIM-4GEF

0.70 kg (1.54 lb)

N/A

6.90 W

HMIM-8GEF

0.60 kg (1.32 lb)

N/A

11.20 W

RT-HMIM-4GEF-V2

0.65 kg (1.43 lb)

8.97 W

9.10 W

RT-HMIM-8GEF-V2

0.70 kg (1.54 lb)

13.56 W

13.70 W

HMIM-8GSWF

0.60 kg (1.32 lb)

N/A

22.00 W

RT-HMIM-4XP

0.70 kg (1.54 lb)

4.73 W

5.10 W

HMIM-1ATM-OC3

N/A

N/A

5.80 W

HMIM-1POS

0.50 kg (1.10 lb)

N/A

5.10 W

RT-HMIM-2POS-STM1

0.70 kg (1.54 lb)

N/A

17.80 W

RT-HMIM-4POS-STM1/4

0.70 kg (1.54 lb)

N/A

17.80 W

HMIM-1CPOS

0.70 kg (1.54 lb)

N/A

10.00 W

HMIM-2CPOS

0.60 kg (1.32 lb)

N/A

11.50 W

HMIM-1E1

N/A

N/A

4.50 W

HMIM-2E1

N/A

N/A

4.61 W

HMIM-4E1

N/A

N/A

4.71 W

HMIM-1E1-F

N/A

N/A

4.50 W

HMIM-2E1-F

N/A

N/A

4.61 W

HMIM-4E1-F

N/A

N/A

4.71 W

HMIM-8E1(75)

N/A

N/A

4.90 W

HMIM-8E1(75)-F

N/A

N/A

4.90 W

RT-HMIM-2E1-V3

0.65 kg (1.43 lb)

4.28 W

4.30 W

RT-HMIM-4E1-V3

0.65 kg (1.43 lb)

4.42 W

4.60 W

RT-HMIM-8E1-V3

0.70 kg (1.54 lb)

4.60 W

4.90 W

HMIM-2T1

N/A

N/A

5.10 W

HMIM-4T1-F

N/A

N/A

5.30 W

HMIM-2E1T1

0.60 kg (1.32 lb)

N/A

5.70 W

HMIM-4E1T1

0.60 kg (1.32 lb)

N/A

5.70 W

HMIM-8E1T1

0.60 kg (1.32 lb)

N/A

5.70 W

HMIM-2E1T1-F

0.70 kg (1.54 lb)

N/A

5.70 W

HMIM-4E1T1-F

0.70 kg (1.54 lb)

N/A

5.70 W

HMIM-8E1T1-F

0.60 kg (1.32 lb)

N/A

5.70 W

HMIM-1CE3

N/A

N/A

11.30 W

HMIM-2SAE

N/A

N/A

6.71 W

HMIM-4SAE

N/A

N/A

7.00 W

HMIM-8SAE

N/A

N/A

8.00 W

RT-HMIM-4SAE-V2

0.65 kg (1.43 lb)

1.56 W

4.20 W

RT-HMIM-8SAE-V2

0.70 kg (1.54 lb)

1.80 W

6.00 W

HMIM-8ASE

N/A

N/A

4.00 W

HMIM-16ASE

0.60 kg (1.32 lb)

N/A

5.00 W

RT-HMIM-8ASE-V2

0.70 kg (1.54 lb)

N/A

3.00 W

RT-HMIM-16ASE-V2

0.85 kg (1.87 lb)

3.00 W

3.10 W

HMIM-1E1POS

1.00 kg (2.20 lb)

N/A

21.60 W

HMIM-16FXS

N/A

N/A

21.19 W

HMIM-8FXS8FXO

N/A

N/A

15.22 W

HMIM-2VE1

0.60 kg (1.32 lb)

N/A

10.80 W

HMIM-2VT1

N/A

N/A

10.75 W

HMIM-1VE1

N/A

N/A

9.50 W

HMIM-1VT1

N/A

N/A

9.50 W

HMIM-4FXS

0.50 kg (1.10 lb)

N/A

6.30 W

HMIM-4FXO

0.60 kg (1.32 lb)

N/A

3.50 W

HMIM-4E&M

0.60 kg (1.32 lb)

N/A

7.20 W

HMIM-8E&M

0.85 kg (1.87 lb)

N/A

12.00 W

HMIM-6AM

N/A

N/A

12.00 W

HMIM-6FCM

N/A

N/A

9.90 W

HMIM-CNDE-SJK

0.65 kg (1.43 lb)

N/A

6.60 W

HMIM-Adapter

N/A

N/A

2.00 W

DHMIM-1DM

1.80 kg (3.97 lb)

N/A

45.00 W

DHMIM-1E1POS1DM

1.20 kg (2.65 lb)

N/A

58.60 W

VPM2 512

N/A

N/A

10.00 W

VPM2 256

N/A

N/A

6.12 W

VPM2 128

N/A

N/A

5.76 W

RT-XMIM-8GEE-R

0.65 kg (1.43 lb)

5.12 W

8.80 W

RT-XMIM-8GEF-R

0.65 kg (1.43 lb)

10.00 W

13.00 W

RT-XMIM-4XP

0.75 kg (1.65 lb)

20.10 W

23.60 W

RT-XMIM-1POS

0.60 kg (1.32 lb)

8.70 W

9.70 W

RT-XMIM-2POS

0.60 kg (1.32 lb)

9.76 W

10.30 W

RT-XMIM-1CPOS

0.64 kg (1.41 lb)

8.80 W

11.00 W

RT-XMIM-2E1

0.60 kg (1.32 lb)

4.30 W

5.00 W

RT-XMIM-4E1

0.65 kg (1.43 lb)

4.60 W

5.40 W

RT-XMIM-8E1

0.65 kg (1.43 lb)

6.44 W

6.80 W

RT-XMIM-CNDE-SJK

0.65 kg (1.43 lb)

12.00 W

12.50 W

RT-SSD-960G

0.50 kg (1.10 lb)

9.00 W

11.00 W

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网