- Table of Contents
- Related Documents
-
| Title | Size | Download |
|---|---|---|
| 01-Text | 4.27 MB |
1 Router chassis
Chassis views
RA5100
Figure1-1 RA5100 front panel
|
(1) 10GE fiber ports 0 to 5 |
(2) GE fiber ports 6 to 13 |
(3) GE copper ports 14 to 17 |
|
(4) ToD port |
(5) CLK port |
(6) Console port (CONSOLE) |
|
(7) Grounding screw |
(8) DC power receptacles |
(9) Reset button (RESET) |
|
(10) Management Ethernet port (MANAGEMENT) |
(11) ALMI/ALMO port |
|
RA5100-HI
Figure1-2 RA5100-HI front panel
|
(1) 10GE fiber ports 0 to 11 |
(2) GE fiber ports 12 to 19 |
(3) GE copper ports 20 to 23 |
|
(4) ToD port |
(5) CLK port |
(6) Console port (CONSOLE) |
|
(7) Grounding screw |
(8) DC power receptacles |
(9) Reset button (RESET) |
|
(10) Management Ethernet port (MANAGEMENT) |
(11) ALMI/ALMO port |
|
RA5100-G-HI
Figure1-3 RA5100-G-HI front panel
|
(1) 100GE fiber ports 0 and 1 |
(2) 25GE fiber ports 2 to 17 |
(3) GE fiber ports 18 to 33 |
|
(4) GE copper ports 34 to 37 |
(5) Console port (CONSOLE) |
(6) ALMI/ALMO port |
|
(7) Reset button (RESET) |
(8) DC power receptacles |
(9) CLK/ToD port |
|
(10) Management Ethernet port (MANAGEMENT) |
(11) DIAG button |
(12) Grounding screw |
|
|
NOTE: If you insert a CSFP optical module into a GE fiber port, that GE fiber port occupies two interface numbers. For example, interfaces 18 and 19 indicate one port and interfaces 20 and 21 indicate another port, and so on. If you insert an SFP transceiver module, the black-printed interface numbers on the panel are used, such as 19, 20, 23, 24, 27, 28, 31, and 32. |
RA5100-G-HI-AC
Figure1-4 RA5100-G-HI-AC front panel
|
(1) 100GE fiber ports 0 and 1 |
(2) 25GE fiber ports 2 to 17 |
(3) GE fiber ports 18 to 33 |
|
(4) GE copper ports 34 to 37 |
(5) Console port (CONSOLE) |
(6) ALMI/ALMO port |
|
(7) Reset button (RESET) |
(8) AC power receptacles |
(9) CLK/ToD port |
|
(10) Management Ethernet port (MANAGEMENT) |
(11) DIAG button |
(12) Grounding screw |
|
|
NOTE: If you insert a CSFP optical module into a GE fiber port, that GE fiber port occupies two interface numbers. For example, interfaces 18 and 19 indicate one port and interfaces 20 and 21 indicate another port, and so on. If you insert an SFP transceiver module, the black-printed interface numbers on the panel are used, such as 19, 20, 23, 24, 27, 28, 31, and 32. |
RA5100-G-EI
Figure1-5 RA5100-G-EI front panel
|
(1) 10GE fiber ports 0 to 5 |
(2) GE fiber ports 6 to 13 |
(3) GE copper ports 14 to 17 |
|
(4) Console port (CONSOLE) |
(5) ALMI/ALMO port |
(6) Reset button (RESET) |
|
(7) DC power receptacles |
(8) CLK/ToD port |
(9) Management Ethernet port (MANAGEMENT) |
|
(10) DIAG button |
(11) Grounding screw |
|
RA5100-G-EI-AC
Figure1-6 RA5100-G-EI-AC front panel
|
(1) 10GE fiber ports 0 to 5 |
(2) GE fiber ports 6 to 13 |
(3) GE copper ports 14 to 17 |
|
(4) Console port (CONSOLE) |
(5) ALMI/ALMO port |
(6) Reset button (RESET) |
|
(7) AC power receptacles |
(8) CLK/ToD port |
(9) Management Ethernet port (MANAGEMENT) |
|
(10) DIAG button |
(11) Grounding screw |
|
LEDs
RA5100/RA5100-HI
The RA5100 and RA5100-HI routers have the same LEDs. This section describes the RA5100-HI router LEDs.
Figure1-7 RA5100 router LEDs
|
(1) System status LED (SYS) |
(2) Running status LED (RUN) |
(3) Clock synchronization LED (SYNC) |
|
(4) High severity alarm LED (ALARM H) |
(5) Low severity alarm LED (ALARM L) |
(6) 10GE fiber port LEDs 0 to 11 |
|
(7) GE fiber port LEDs 12 to 19 |
(8) GE copper port LEDs 20 to 23 |
(9) Management Ethernet port LED |
|
(10) Power supply LEDs |
||
RA5100-G-HI
Figure1-8 RA5100-G-HI front panel
|
(1) Low severity alarm LED (ALARM L) |
(2) High severity alarm LED (ALARM H) |
(3) Clock synchronization LED (SYNC) |
|
(4) Running status LED (RUN) |
(5) Power supply LED (PWR2) |
(6) Power supply LED (PWR1) |
|
(7) System status LED (SYS) |
(8) Management Ethernet port LED |
(9) GE copper port LEDs 34 to 37 |
|
(10) GE fiber port LEDs 18 to 33 |
(11) 25GE Ethernet port LEDs 2 to 17 |
(12) 100GE Ethernet port LEDs 0 and 1 |
RA5100-G-HI-AC
Figure1-9 RA5100-G-HI-AC front panel
|
(1) Low severity alarm LED (ALARM L) |
(2) High severity alarm LED (ALARM H) |
(3) Clock synchronization LED (SYNC) |
|
(4) Running status LED (RUN) |
(5) Power supply LED (PWR2) |
(6) Power supply LED (PWR1) |
|
(7) System status LED (SYS) |
(8) Management Ethernet port LED |
(9) GE copper port LEDs 34 to 37 |
|
(10) GE fiber port LEDs 18 to 33 |
(11) 25GE Ethernet port LEDs 2 to 17 |
(12) 100GE Ethernet port LEDs 0 to 1 |
RA5100-G-EI
Figure1-10 RA5100-G-EI front panel
|
(1) Low severity alarm LED (ALARM L) |
(2) High severity alarm LED (ALARM H) |
(3) Clock synchronization LED (SYNC) |
|
(4) Running status LED (RUN) |
(5) Power supply LED (PWR2) |
(6) Power supply LED (PWR1) |
|
(7) System status LED (SYS) |
(8) Management Ethernet port LED |
(9) GE copper port LEDs 14 to 17 |
|
(10) GE fiber port LEDs 6 to 13 |
(11) 10GE fiber port LEDs 0 to 5 |
|
RA5100-G-EI-AC
Figure1-11 RA5100-G-EI-AC front panel
|
(1) Low severity alarm LED (ALARM L) |
(2) High severity alarm LED (ALARM H) |
(3) Clock synchronization LED (SYNC) |
|
(4) Running status LED (RUN) |
(5) Power supply LED (PWR2) |
(6) Power supply LED (PWR1) |
|
(7) System status LED (SYS) |
(8) Management Ethernet port LED |
(9) GE copper port LEDs 14 to 17 |
|
(10) GE fiber port LEDs 6 to 13 |
(11) 10GE fiber port LEDs 0 to 5 |
|
LED descriptions
|
LED |
Status |
Description |
|
System status LED (SYS) |
Flashing green at 8 Hz |
· BIOS stage—The BIOS is starting up. · BootWare stage—The system software image is being decompressed. |
|
Flashing yellow at 1 Hz |
· BIOS stage—The memory does not exist or system initialization has failed. · BootWare stage—The SDRAM has failed the POST. |
|
|
Flashing yellow at 8 Hz |
The extended segment does not exist (BIOS stage). |
|
|
Steady green |
· BootWare stage—The SDRAM is being tested. · Comware stage—The kernel is starting up. |
|
|
Flashing green at 1 Hz |
The Comware system is starting up or is operating correctly (Comware stage). |
|
|
Steady yellow |
The boot.bin file does not exist (BootWare stage). |
|
|
Off |
A system hardware failure has occurred. |
|
|
Running status LED (RUN) (for RA5100/5100-HI only) |
Flashing green at 1 Hz |
The BIOS has started up and BootWare is starting up. |
|
Flashing red at 1 Hz |
The BIOS is starting up. |
|
|
Steady green |
The Comware system is starting up or is operating correctly. |
|
|
Off |
No power is present. |
|
|
Running status LED (RUN) |
Flashing green at 1 Hz |
BootWare is starting up. |
|
Flashing green at 8 Hz |
The system is collecting diagnostic information. |
|
|
Steady green |
The Comware system is starting up or is operating correctly. |
|
|
Off |
No power is present. |
|
|
Clock synchronization LED (SYNC) |
Steady green |
· The system clock is in free-run mode and no clock source is specified for the system clock. · The system clock is in traced mode and is tracing a clock source in the clock source priority list. · The system clock is in locked mode, and the PTP clock is tracing a clock source. |
|
Steady yellow |
· The system has lost all its clock sources except the internal clock source. The system clock is in holdover mode or free-run mode. · The system clock is in locked mode but no clock source is available. The PTP clock is in holdover mode or free-run mode. |
|
|
Off |
No power is present, or the system clock is not synchronized during system startup. |
|
|
High severity alarm LED (ALARM H) |
Steady red |
A high severity alarm has occurred on the device. |
|
Off |
No high severity alarm has occurred on the device. |
|
|
Low severity alarm LED (ALARM L) |
Steady yellow |
A low severity alarm has occurred on the device. |
|
Off |
No low severity alarm has occurred on the device. |
|
|
100GE Ethernet port LEDs |
Steady green |
A 100 Gbps link is present on the port. |
|
Flashing green |
The port is sending or receiving data at 100 Gbps. |
|
|
Steady yellow |
A 50 Gbps link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 50 Gbps. |
|
|
Off |
No link is present on the port. |
|
|
25GE Ethernet port LEDs |
Steady green |
A 25 Gbps link is present on the port. |
|
Flashing green |
The port is sending or receiving data at 25 Gbps. |
|
|
Steady yellow |
A 10GE/GE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 10 Gbps or 1 Gbps. |
|
|
Off |
No link is present on the port. |
|
|
10GE fiber port LED |
Steady green |
A 10GE link is present on the port. |
|
Flashing green |
The port is sending or receiving data at 10 Gbps. |
|
|
Steady yellow |
A GE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 1 Gbps. |
|
|
Off |
No link is present on the port. |
|
|
GE fiber port LED |
Steady green |
A GE link is present on the port. |
|
Flashing green |
The port is sending or receiving data at 1 Gbps. |
|
|
Steady yellow |
An FE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
GE copper port LED |
Steady green |
A GE link is present on the port. |
|
Flashing green |
The port is sending or receiving data at 1 Gbps. |
|
|
Steady yellow |
A FE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
Management Ethernet port LED |
Steady green |
A GE link is present on the port. |
|
Flashing green |
The port is sending or receiving data at 1 Gbps. |
|
|
Steady yellow |
An FE link is present on the port. |
|
|
Flashing yellow |
The port is sending or receiving data at 100 Mbps. |
|
|
Off |
No link is present on the port. |
|
|
Power supply LED (PWR1/PWR2) |
Steady green |
The power supply is operating correctly. |
|
Off |
No power is present. |
Interface numbering
Conventions
The ports are numbered in the interface-type X/Y/Z format, where:
· interface-type—Interface type, for example, Console, GigabitEthernet, or Ten-GigabitEthernet.
· X—Number of the slot where the interface module resides. The slot number is fixed at 1 for interfaces on the device panel.
· Y—Number of the subslot. The device does not support subslots. The value for the Y argument is fixed at 0.
· Z—Number marked for the port on the device panel, starting from 0.
Examples
· GE copper ports 34 to 37 on the RA5100-G-HI router are numbered GigabitEthernet 1/0/34 to GigabitEthernet 1/0/37.
· If an SFP transceiver module is inserted into a GE fiber port on the RA5100-G-HI router, the ports are numbered GigabitEthernet 1/0/19, GigabitEthernet 1/0/20, GigabitEthernet 1/0/23, GigabitEthernet 1/0/24, GigabitEthernet 1/0/27, GigabitEthernet 1/0/28, GigabitEthernet 1/0/31, and GigabitEthernet 1/0/32.
Technical specifications
If a ToD port or CLK/ToD port on the device is used, use the shielded twisted pair cable to avoid clock synchronization anomaly.
Table1-1 and Table1-2 shows the technical specifications of the routers.
Table1-1 RA5100/RA5100-HI technical specifications
|
Item |
RA5100 |
RA5100-HI |
|
Dimensions (W × D × H), excluding rubber feet and mounting brackets |
440 × 205 × 44 mm (17.32 × 8.07 × 1.73 in) |
440 × 205 ×44 mm (17.32 × 8.07 × 1.73 in) |
|
Dimensions (W × D × H), including packaging |
576 × 365 × 161 mm (22.68 × 14.37 × 6.34 in) |
576 × 365 × 161 mm (22.68 × 14.37 × 6.34 in) |
|
Chassis height |
1U |
1U |
|
Weight (excluding packaging) |
2.15 kg (4.74 lb) |
2.25 kg (4.96 lb) |
|
Weight (including packaging) |
4.55 kg (10.03 lb) |
4.75 kg (10.47 lb) |
|
Memory type and size |
4 GB DDR4 |
4 GB DDR4 |
|
Flash |
4 GB |
4 GB |
|
Power supply mode |
Embedded DC |
Embedded DC |
|
Rated input voltage of AC power supplies |
- |
- |
|
Input voltage range of AC power supplies |
- |
- |
|
Rated voltage range of DC power supplies |
–48V DC to –60V DC |
–48V DC to –60V DC |
|
Input voltage range of DC power supplies |
–38.4V DC to –72V DC |
–38.4V DC to –72V DC |
|
Max. input current |
5A |
5A |
|
Console port (CONSOLE) |
1 |
1 |
|
Console port type |
RJ45 |
RJ45 |
|
GE copper port |
4 |
4 |
|
GE fiber port |
8 |
8 |
|
10GE fiber port |
6 |
12 |
|
25GE fiber port |
- |
- |
|
100GE fiber port |
- |
- |
|
Management Ethernet port (MANAGEMENT) |
1 |
1 |
|
ALMI/ALMO port |
1 |
1 |
|
ToD port |
1 |
1 |
|
CLK port |
1 |
1 |
|
CLK/ToD port |
- |
- |
|
DIAG button |
- |
- |
|
Reset button (RESET) |
1 |
1 |
|
Fan type |
Embedded fans |
Embedded fans |
|
Heat dissipation |
Air cooling |
Air cooling |
|
Ambient noise (sound power |
44.8 dBA |
44.8 dBA |
|
RTC |
Supported |
Supported |
|
Ambient temperature |
· Operating: –20°C to +60°C (–4°F to +140°F) · Storage: –40°C to +70°C (–40°F to +158°F) |
· Operating: –20°C to +60°C (–4°F to +140°F) · Storage: –40°C to +70°C (–40°F to +158°F) |
|
Ambient humidity (noncondensing) |
· Operating: 5%RH to 95%RH · Storage: 5%RH to 95%RH |
· Operating: 5%RH to 95%RH · Storage: 5%RH to 95%RH |
|
Operating altitude for long-term operation |
–60 to +5000 m (–196.8504 to 16404.20 ft) |
–60 to +5000 m (–196.8504 to 16404.20 ft) |
Table1-2 RA5100-G-EI/RA5100-G-EI-AC/RA5100-G-HI/RA5100-G-HI-AC technical specifications
|
item |
RA5100-G-EI |
RA5100-G-EI-AC |
RA5100-G-HI |
RA5100-G-HI-AC |
|
Dimensions (W × D × H), excluding rubber feet and mounting brackets |
440 × 205 × 40 mm (17.32 × 8.07 × 1.57 in) |
440 × 205 × 40 mm (17.32 × 8.07 × 1.57 in) |
440 × 205 × 40 mm (17.32 × 8.07 × 1.57 in) |
440 × 205 × 40 mm (17.32 × 8.07 × 1.57 in) |
|
Dimensions (W × D × H), including packaging |
576 × 365 × 161 mm (22.68 × 14.37 × 6.34 in) |
576 × 365 × 161 mm (22.68 × 14.37 × 6.34 in) |
576 × 365 × 161 mm (22.68 × 14.37 × 6.34 in) |
576 × 365 × 161 mm (22.68 × 14.37 × 6.34 in) |
|
Chassis height |
1U |
1U |
1U |
1U |
|
Weight (excluding packaging) |
3.0 kg |
3.0 kg |
3.1 kg |
3.1 kg |
|
Weight (including packaging) |
5.0 kg |
5.15 kg |
5.35 kg |
5.5 kg |
|
Memory type and size |
8GB DDR4 |
8GB DDR4 |
8GB DDR4 |
8GB DDR4 |
|
Flash |
8GB |
8GB |
8GB |
8GB |
|
Power supply mode |
Embedded DC |
Embedded AC |
Embedded DC |
Embedded AC |
|
Rated input voltage of AC power supplies |
- |
100V AC to 240V AC, 50Hz/60Hz |
- |
100V AC to 240V AC, 50Hz/60Hz |
|
Input voltage range of AC power supplies |
- |
90V AC to 290V AC, 50Hz/60Hz |
- |
90V AC to 290V AC, 50Hz/60Hz |
|
Rated input voltage of DC power supplies |
–48V DC to –60V DC |
- |
–48V DC to –60V DC |
- |
|
Input voltage range of DC power supplies |
–38.4V DC to –72V DC |
- |
–38.4V DC to –72V DC |
- |
|
Max. input current |
5A |
3A |
5A |
3A |
|
Console port (CONSOLE) |
1 |
1 |
1 |
1 |
|
Console port type |
RJ45 |
RJ45 |
RJ45 |
RJ45 |
|
GE copper port |
4 |
4 |
4 |
4 |
|
GE fiber port |
8 |
8 |
16 × CSFP fiber ports or 8 × SFP fiber ports |
16 × CSFP fiber ports or 8 × SFP fiber ports |
|
10GE fiber port |
6 |
6 |
- |
- |
|
25GE fiber port |
- |
- |
16 |
16 |
|
100GE fiber port |
- |
- |
2 |
2 |
|
Management Ethernet port (MANAGEMENT) |
1 |
1 |
1 |
1 |
|
ALMI/ALMO port |
1 |
1 |
1 |
1 |
|
ToD port |
- |
- |
- |
- |
|
CLK port |
- |
- |
- |
- |
|
CLK/ToD port |
1 |
1 |
1 |
1 |
|
DIAG button |
1 |
1 |
1 |
1 |
|
Reset button (RESET) |
1 |
1 |
1 |
1 |
|
Fan type |
Embedded fans |
Embedded fans |
Embedded fans |
Embedded fans |
|
Heat dissipation |
Air cooling |
Air cooling |
Air cooling |
Air cooling |
|
Ambient noise (sound power) |
35.2 dBA |
35.2 dBA |
35.7 dBA |
35.7 dBA |
|
RTC |
Supported |
Supported |
Supported |
Supported |
|
Ambient temperature |
· Operating: –20°C to +60°C (–4°F to +140°F) · Storage: –40°C to +70°C (–40°F to +158°F) |
|||
|
Ambient humidity (noncondensing) |
· Operating: 5%RH to 95%RH · Storage: 5%RH to 95%RH |
|||
|
Operating altitude for long-term operation |
–60 to +5000 m (–196.8504 to 16404.20 ft) |
|||
Power cord specifications
A DC power cord is used to connect a DC power supply to an external DC power supply system. See Table1-3 for the DC power cords supported by the RA5100, RA5100-HI, RA5100-G-HI, and RA5100-G-EI routers.
Table1-3 DC power cord specifications
|
BOM No. |
Length |
|
0404A17L |
5 m (16.40 ft) |
|
0404A2HE |
15 m (49.21 ft) |